Impedence Cure
Impedence Cure
Page 1
STEP 1 :
The Total Cooling
Requirements
STEP 2 :
Total System Resistance /
System Characteristic Curve
STEP 3 :
System Operating Point
Page 2
CFM = 3160
Then, we obtain the following equations :
Obviously we have
W = CFM x D
where, D = Density
By substitution, we obtain :
Q (CFM)=
Q (CFM)=
3.16 x P
Tf
Q (M3 / Min)=
Q
Cp x D x T
1.76 x P
Tc
0.09 x P
Tf
0.05 x P
Tc
D T = D T1 - D T2
TF
50
45
40
35
30
25
20
15
10
5
90
81
72
63
54
45
36
27
18
9
0.5
18
20
22
25
29
35
44
59
88
176
1 1.5 2
35
39
44
50
59
75
88
117
176
351
53
59
66
75
88
105
132
176
264
527
70
78
88
100
117
141
176
234
351
704
2.5 3 3.5
88
98
110
125
146
176
220
293
439
879
105
117
132
151
176
211
264
351
527
1055
4 4. 5
123 141
137 156
154 176
176 201
205 234
246 281
308 351
410 469
615 704
1230 1406
158
176
195
226
264
316
396
527
791
1582
5
176
195
220
251
293
351
439
586
879
1758
3.16 x 500(watts)
= 79 CFM
20
or
Q=
3
0.09 x 500(watts)
= 2.25 M Min.
20
1.76 x 500(watts)
= 88 CFM
10
or
Page 3
Q=
3
0.05 x 500(watts)
= 2.5 M Min.
10
Page 4
606025mm
Fan with Middle Speed
606025mm
Fan with Low and Middle Speed
Page 5
Example 3. Figure shows the air performance curves of 40x 40x 6mm(Curve 3),
30x 30x 6mm(Curve 2) and 25x 25x
6mm(Curve 1) DC fans with middle speed.
Case 1 : If the system acquires a system
resistance of 0.025 Inch-H2O and requires
an air flow of 2 CFM to cool off, 40x 6mm
DC fan is recommended.(Please refer to
the Operation Point B.)
Case 2 : If there are more components
added to the system and/or there is a
more compact physical re-configuration,
there will be a higher system resistance
acquired. Now, assume that the system
resistance is increased to 0.038 Inch-H2O
and requires 0.85 CFM to cool off the
system, there are two fans, 40x 6mm and
30x 6mm, available for selection. (Please
refer to Operating Point A.) Another excellent option for cooling a system with a
high system resistance is Micro DC Blower.
Page 6