PART 2 - TECHNICAL
CONTENTS
A.
B.
C.
D.
E.
F.
MATERIAL OF CONSTRUCTION
A.
1.0
GENERAL
1.1
Scope
This specification together with the design data sheets covers the requirements for Centrifugal
Pumps & Drivers. The LPG Pumps shall conform to API 610 (10th Edition). The vendor shall
separately indicate the deviations from the code, if any.
The provisions of API 610 (10th Edition), shall supersede the specifications given below. In
case of any conflict, deviation or discrepancy, the same shall be brought out by the bidder
clearly in their Unpriced Bid Where ever there is a conflict/mismatch in interpretation of
various terms the following sequence of prioty order shall be considered with No 1 having
the max weightage and No 5 the Minimum.
1.
2.
3.
4.
5.
1.2
Painting as specified.
Engineering Services
The Vendor shall provide engineering services, which shall include, but not necessarily be
limited to, the following:
Providing/coordinating detailed design of all equipment and components within the scope
of supply.
Resolving engineering queries related to the equipment and components within the scope of
supply.
1.3
1.4
Performing all relevant calculations pertaining to the equipment and components within the
scope of supply. Providing all Performance Curves related to the Equipments
Providing quality assurance, including all sub-vendors with respect to ISO 9000 or
equivalent.
Quality Assurance.
Exclusions
Power & Control Cables and associated cable glands & lugs.
Modifications
Any exceptions or additions to this specification shall be mentioned on the design data sheet.
1.5
Duty
The pump shall be suitable for continuous duty.
2.0
2.1
DESIGN
General
Design pressure shall be defined as the sum of the maximum suction pressure plus the peak
differential pressure developed with maximum diameter impeller.
Pumps shall preferably operate at standard electric motor speeds for the maximum rated output.
2.2
Drivers
Motor drivers shall be selected with the following margins over the absorbed HP of the pump at
the design duty point.
--------------------------------------------------------------------------------------------------------Motor Ratings (% of Absorbed HP)
Range of absorbed HP of the pump
Motors with
Motors with
unity service
1.15 service
factor
factor
--------------------------------------------------------------------------------------------------------Upto 25 HP
125
115
Above 25 upto 100 HP
115
105
Above 100 HP
110
100
--------------------------------------------------------------------------------------------------------However, the motor shall not be less than the maximum absorbed HP for the selected impeller.
2.3
At speeds over 1,800 rpm if rated capacity exceeds 70 Cu.M./hr. and impeller diameter is
more than 150 mm.
At speeds over 1,800 rpm for two or more stages.
At speeds over 3,800 rpm.
During operation at maximum continuous speed or at any other specified operating speed, the
double amplitude of vibration in any plane measured on the shaft adjacent to the bearing
housing shall not exceed the values given below :
--------------------------------------------------------------------------------Rated speed RPM
Double amplitude
Centimeters
--------------------------------------------------------------------------------Through 1000 RPM
0.00752
Over 1000 through 4000
0.00635
Over 4000 through 6000
0.00508
Over 6000
0.00381
--------------------------------------------------------------------------------Where it is not possible to measure vibrations on the shaft, the total amplitude of vibration shall
be measured at both bearings or bearing housing and shall not exceed 50 percent of the foregoing
values.
Critical speeds shall be at least 20 percent above or below the normal operating speeds for pumps
with flexible shafts and at least 20 percent above the maximum operating speed for pumps with
stiff shafts.
2.4
Flanges
Suction and discharge connections shall be flanged in accordance with ANSI B 16.5 300#
Welded Neck Raised Flanges, standards and the suction flanges should be designed for the same
pressures as the discharge flanges to permit testing under the required full test pressure.
2.5
Castings
No carbon steel bolting shall be used in steel pumps, ASTM-A 193, Grade B7 or equivalent shall
be used, except as noted for special services.
Pumps in vacuum service shall be provided with vents consisting of extra heavy seamless nipples
and forged steel valves.
All casings shall be provided with 20 mm minimum plugged drain connections. The casing
drains of pumps handling corrosive fluids containing erosive solids shall have bar stock
plugs, ground flush with the inside of the casing.
All tapped holes shall be plugged with solid plugs. This shall include cooling water
connections, stuffing box connections and seal gland plate connections as well as vent and drain
connections. Carbon steel plugs shall be used in tapped holes in cast iron parts. For other than
cast iron parts, the plugs shall be of the same metal as the parts containing the tapped holes.
Plugs shall have shanks at least 40 mm in length to permit the use of a pipe wrench.
2.6
Impellers
Impellers shall have the characteristics of generally decreasing head with increasing capacity
from shut off to normal capacity. In boiler feed service, shut off head shall be approximately 20
percent higher than the design point head.
Pump shall have an impeller of size which is mid way between the maximum and minimum sizes
or near the minimum size.
Where more than one pump is specified, they shall have identical characteristics for running
successfully in parallel.
The tenderer shall state the minimum permissible capacity at rated speed without excessive
temperature rise and radial thrust. Where necessary, an automatic by pass connection shall be
provided to prevent excessive temp. rise at zero flow. Automatic recirculation valve of Key stone/
Schroedahl make shall be supplied along with each set of pumps.
2.8
Bearings
The bearings and bearing lubrication system shall be selected for the service conditions and shall
be capable of operating continuously with a lubricant outlet temperature not exceeding 75_ C at
any bearing when the ambient temperature is 35 degree C. Thrust bearings shall require no water
cooling.
Bearings shall have minimum rated life of 25,000 working hours (B-10 rating).
Bearing housing shall be designed to prevent entry of gland leakage, water or dust.
Oil lubricated bearings shall be equipped with constant level oilers. The bearing shall be anti
friction type with rotation independent automatic lubrication by internal oil circulation.
Grease lubricated bearings shall not be used.
Pump design shall be capable of withstanding reverse rotation for a short duration.
Difference between NPSHR NPSHA shall be 1.0 M (min)
2.10
Piping System
Gland seal piping and flushing oil manifolds at the pumps shall include dial type thermometer
and pressure gauges with steel bourbon tubes having welded connections. When the pump
suction pressure is below atmospheric, combination vacuum pressure gauges shall be
furnished.
Cooling water manifolds for closed system shall include sight flow indicators and inlet and
outlet shut off valves.
Balancing lines for multi-stage pumps shall be made up with flanged joints; screwed unions
are not acceptable.
Cooling water, gland oil and recirculating piping systems, including all accessories such as
gauges, valves, etc. shall be furnished fully assembled and installed on the pump. The piping
shall be arranged to follow the pump contour as closely as possible and shall be adequately
supported.
When mechanical seals with pumping rings are specified, a cooling water system complete and
cooler shall be provided.
2.11
All the pipe fittings, valves, flow indicator, press indicator, manifold, flanges etc. required for the
flushing arrangement are in the scope of supply of the vendor.
Drawings to be submitted at the offer stage along with the other drawing :
1. Double mechanical seal arrangement.
2. Flushing system layout.
MATERIAL OF CONSTRUCTION
All the equipment & pipe fittings for flushing unit are to be of SS 304.
2.12
Coupling
Spacer type couplings shall be used on vertical shaft pumps equipped with mechanical seals
to permit seal replacement without disturbing the prime mover.
Where motor half couplings are fitted by the pump supplier, he shall take full responsibility for
correct fitting or alignment.
Threaded couplings shall preferably be used only with hollow-shaft motors which have a non
reverse rachet. If threaded couplings are used on vertical pumps, they shall be secured against
reverse rotation without the use of set screws.
When gear type couplings are specified, they shall be heavy duty, forged steel, flexible spacer and
lubricated type.
When disc type couplings are specified, the flexible discs shall be stainless steel.
GENERAL
1.1
1.2
The timely delivery of quality drawings and data is as crucial to an Engineering schedule as
delivery of the equipment itself is to a construction schedule.
1.3
1.4
2.0
2.1
2.2
2.3
Shall include main construction features, details of seals, bearings and other mechanical
details such as the governor of the driver.
2.4
3.0
3.1
After commitment/placement of P.O. and after preliminary drawings and data are submitted, the
vendor shall provide certified drawings and data as specified below.
DIMENSIONED OUTLINE DRAWINGS
The vendor supplying the driven equipment shall submit a combined dimensioned
drawing of pump and driver.
This drawing(s) shall include :
outline
a)
Dimensions of base plates complete with diameter, number and location of bolt holes and
thickness of metal through which bolt must pass.
b)
c)
Identification, size, rating and location of every terminal connections. The terminal
connections referred to above shall include main suction and discharge nozzles,
cooling water, lube seal and control oil, ventilating and instrument air, casing vents and
drains, instrument and electrical connections.
d)
All horizontal and vertical clearances necessary for dismantling purposes with location of
lifting lugs.
e)
f)
g)
Magnitude and direction of the expansion movement of main nozzles and the permitted
piping forces and moments on the nozzles.
Dimensioned outline drawings shall also be provided for Auxiliary Equipment. This covers
equipment whether or not mounted on the main base plate and includes lube and seal oil system,
overhead tanks and seal oil traps.
FOUNDATION LOADING DIAGRAMS
These drawings shall include :
a)
b)
Size and location of foundation cut-outs, if required, for downward nozzles and drains.
c)
The location and magnitude of out-of-balance forces and moments transmitted to the
foundation for reciprocating compressors and/or drivers.
The final definition of the gas or fluid flows, lube, seal oil and control oil, all
instrumentation valves, safety devices and control schemes.
b)
Components and Instrument Lists : These are lists of all components and instruments
show on the schematics identifying the manufacturer and type, with operating and
design conditions and settings. The same symbol shall be used on outline drawings and
schematics for consistent identification of each terminal connection.
DETAIL DRAWINGS
Cross sectional drawings and detail drawings.
GA Drgs shall be submitted to HPCL within 02 weeks of placement of PO
ERECTION/ASSEMBLY DRAWINGS
In accordance with the standard practice of the manufacturer.
CALCULATIONS
Torsional and lateral critical speed analysis of the complete rotating assembly. The documents
shall include :
a)
b)
c)
Calculation method.
d)
e)
Conclusions including comments on possible exciting forces and frequencies.
PREDICTED PERFORMANCE CURVES
These curves shall include the specified duties and design conditions as required on the data
sheet.
MANUFACTURER'S DATA REPORTS
a)
b)
c)
d)
SCOPE
1.1
This specification covers the general requirements for 3 phase medium voltage induction motors.
The motor to be supplied shall be suitable for operation through a Variable ( 0 100%)
Frequency Drive for optimum energy utilization. Supply of the VFD is not included in the
scope of this tender.
2.0
DELETED
3.0
Standards
All motors shall comply, wherever applicable with the latest issues of the following standards:
IS : 325 - Three phase induction motors.
IS : 1231 - Dimensions of three phase foot mounted motors.
IS : 2148 - Flame proof enclosures of electrical apparatus.
IS:2223 Dimensions of flange mounted A.C. induction motors.
IS:2253 Designations for types of construction and mounting arrangements of rotating
electrical machinery.
IS : 2254 - Dimensions of vertical shaft motors for pumps.
4.0
General Description
4.1
The motors shall be liberally designed as regards its pull-out torque, pull-out voltage and its
ability to ride through voltage dips during system disturbances.
4.2
Motor frame sizes shall be in accordance with I.E.C. Recommendation in the absence of Indian
Standards.
4.3
Motors for hazardous areas shall be of a design for which approval has been obtained from
the Central Mining & Research Station, Dhanbad, for use in the divisions of areas specified.
4.4
All motors approved as per clause 4.3 above shall have a separate name plate carrying the
details of such approval an d fixed adjacent to the main plate.
4.5
The motors shall have additional accessories like space heaters, embedded temperature
detectors etc. if specified in the data sheet.
5.0
5.1
Motors specified with weather proof / explosion proof enclosures, shall be suitable for outdoor operation subjected to direct sun and rain without further protection (like canopy, hood
etc.) from the weather.
6.0
Insulation
6.1
The windings shall be insulated with the class of insulation specified in the data sheet.
6.2
The windings shall be given protective coatings to withstand service in the environment
specified.
6.3
The windings shall be provided with moisture protective coating to prevent absorption of
moisture.
7.0
Terminal Boxes
7.1
All the six ends of the winding shall be brought out to the terminal block and marked.
7.3
Terminal box shall be on the right hand side of the motor when viewed from the shaft end
unless specified otherwise in the data sheet.
7.4
Double compression type cable glands of CCOE approved make suitable for cable sizes given
in the motor data sheet shall be provided for the terminal boxes.
7.5
If space heaters, embedded temperature detectors etc. are specified in the data sheet, separate
terminal boxes with compression type cable glands shall be provided for the same. If the
motor is flame proof, these terminal boxes and cable glands shall also be flame proof, double
compression type approved by CMRS, Dhanbad.
7.6
In case capacitors are envisaged to be connected to the motor terminals (as indicated in the
data sheet) the terminal box shall be of a special design by which sufficient creepage space
between terminals is available and also the terminal box shall be provided with two sets of
cable glands.
7.7
Terminal box covers and cable gland entries shall be effectively sealed against the entry of
moisture and dirt, before the motor leaves the factory.
8.0
Name Plate
8.1
8.2
Ambient temperature for which the motor is designed, type and name of lubricant and bearing
members, shall be indicated in the name plate.
9.0
Lifting Facility
Lubrication
Grease migration shall be prevented.
11.0
Special Requirements
11.1
Where any special requirement such as degree of protection to enclosures, thermal cut-outs,
special cable boxes, extra starting torque or supply of half coupling etc. are specified in the
order, these details shall be clearly recorded in the test certificates or in an attached
supplement.
11.2
Details of bearings shall be given in the test certificates to facilitate ordering or spares.
12.0
Standby Duty
All motors shall be capable of standing idle for long periods without damage to be bearings.
13.0
14.0
Methods of starting
All motors are envisaged to be started direct on line, unless otherwise specified in the data sheet.
15.0
Number of Starts.
All motors shall be suitable for 3 cold and 2 hot consecutive starts unless specified otherwise in
the data sheet.
16.0
Direction of Rotation
All motors shall be suitable for operation in both directions.
17.0
Final Colour
Final color of all motors and pump shall be Aircraft blue - Shade No. 356-as per IS : 5. Bass
frame shall be of Jet black.
NOTES:
1.
2.
Schedule of technical particulars of motors should be filled in and submitted with the offer .
Items marked * in the MV Induction Motor Data Sheet should be filled in by the vendor.
3.
4.
Motors located out door shall be protected by a 1.5-mm thick mild steel canopy.
The motor rating shall be chosen as given below:
Range of absorbed KW Motor Rating
Upto 18.5 KW
18.5 KW - 75 KW
Above 75 KW
5.
The motor shall be so chosen that the start-up time at 80% of the voltage of the motor when
driving the specified load is less than the starting current withstand time (hot) of the motor.
6.
If indigenous motors are offered the motors shall be of Siemens, NGEF, Kirloskar, Crompton
Greaves or Bharat Bijlee make only. No other indigenous make of Motor will be accepted.
VENDORS SCOPE OF SUPPLY
Pumps
Drive
Common Base Plate
Coupling Guard
Coupling
Match Flanges
Automatic Recirculation Valve
(1 no. per pump )
Mechanical Seal
Lubricator
Foundation Bolts
Air Relief Valve
Motor Stool
Differential Pr. switch
Material of Construction: S-5 / S-6 as per API 610 (8th & 10th edition). No deviation with
respect to the Material of Construction for the Pump shall be accepted.
2.
Equipment No.
3.
Motor Rating
4.
5.
Frame size
6.
No load current(Amps)
7.
8.
9.
10.
11.
12.
13.
14.
Slip (percentage)
15.
15.1
At full load
15.2
At 3/4 load
15.3
At 1/2 load
16.
17.
18.
Stator resistance
19.
Total resistance
(with respect to stator)
20.
Total leakage reactance
(with respect to stator)
21.
22.
22.1
Hot (seconds)
22.2
Cold (seconds)
23.
Starting time of motor on
DOL with driven equipment
coupled.
24.
Minimum voltage required for:
starting with the equipment
and corresponding starting
time.
25.
26.
Allowable number of successive starts with driven
equipment.
26.1
26.2
27.
:
:
29.
30.
Design class of rotor as per
NEMA standards.
31.
GD square value of rotor in
KG sq. M.
32.
33.
34.
35.
Thermal withstand
characteristics (hot & cold)
36.
36.1
Hot (seconds)
36.2
Cold (seconds)
37.
37.1
37.2
38.
CCOE Certificate (for
Flame-proof motors)
:
:
40.
Bearings
40.1
40.2
40.3
Make of bearings
: SKF / FAG
41.
Lubricant
41.1
Make
41.2
Type
41.3
42.
43.
43.1
43.2
Rotor current
43.3
Make of brush
43.4
Grade of brush
43.5
44.
45.
46.
2.
3.
Data Sheet
Schedule of technical
particulars
SP
(Initial)
SP
SP
( final)
SP
(final)
Dimensioned General
Arrangement drawing
SP
Speed-torque curve of
motor and drive eqpt.
SP
5.
SP
6.
SP
7.
SP
8.
SP
9.
Itemwise acceptance or
4.
SP
SP
10.
SP
11.
SP
NOTE:
:
:
:
:
:
LPG
C3 AND C4 HYDRO CARBONS
0.5033
: 9.54KG./SQ CM AT 38 DEGREE C
0.209 CST
38 DEG C & above
:
*
:
*
: AS DETAILED IN CHART BELOW
HAZIRA
240 CUM/Hr
Product Transfer from ONGC Complex to
Hazira HPCL LPG plant
2
138
AS PER ENCLOSED DATA SHEET
AS PER ENCLOSED DATA SHEET
SPECIFICATION
MAKER'S NO.
PUMP TYPE
NPSH (REQD.)
NPSH (AV)
IMPELLER TYPE
IMPELLER DIA
MIN.
MAX.
DESIGN
SPEED RPM
CASING SPLIT
SHAFT SEAL TYPE MECH. SEAL
*
Double seal Tandem type of Burgmann
/ sealol ( EPIL ) / Dura metallic
B 16.5 300#
WNRF
PERFORMANCE TEST
AT SITE
AT SHOP
*
MOTOR HP
MOTOR SPEED
B 16.5 300#
*
*
DRIVE DIRECT
LUBRICATION OF PUMP BEARINGS
*
*
MOTOR SUPPLIED
COUPLING SUPPLIED
SHIPPING VOLUME
*
F. MATERIAL OF CONSTRUCTION
Material of Construction shall be strictly S-5 / S-6 as per API 610 (10th edition)
BY PURCHASER
BY MANUFACTURER
BY MANUFACTURER OR PURCHASER
REVISIONS
2
3
ITEM NO.
ATTACHED
ITEM NO.
ATTACHED
ATTACHED NO.
ITEM NO.
BY
DATE
P-10-001 A/B
M-10-001 A/B
4 PUMP
5 MOTOR
6 GEAR
7 TURBINE
NUMBER OF STAGES:
LIQUID (5.1.3)
240
Refer Sheet 2 of 5
10 FLOW, NORMAL
11 OTHER
240
(m/h)
FLAMMABLE
(5.1.5)
12
13 SUCTION PRESSURE MAX./RATED
(kpaA)
1786
676.56
15 DIFFERENTIAL PRESSURE
17 PROCESS VARIATIONS (5.1.4)
(kpaA)
NORMAL
35.00
1092.83
0.5 @ 35 DEG.C
0.09741
MIN.
MAX.
SPECIFIC HEAT, Cp
CONT.
INTERMITTENT (STARTS/DAY)
(kJ/kg C)
CHLORIDE CONCENTRATION
(PPM)
21
(kpaA)
3.35 (m)
(mlc) NPSHA
Note 15 (For tripping of the pump)
138
16 DIFF. HEAD
1109.3
14 DISCHARGE PRESSURE
(PPM)
WET (5.2.1.12c)
(5.12.1.9)
22
23 LOCATION: (5.1.30)
MATERIALS (5.12.1.1)
24
25
26
CL
27
WINTERIZATION REQ'D
ZONE
HEATED
1
OUTDOOR
UNHEATED
GR IIA, IIB
DIV T3
BARREL/CASE
(C)
Yes
TROPICALIZATION REQ'D.
IMPELLER
29
ALTITUDE
30
(m)
BAROMETER
31
RELATIVE HUMIDITY:
(bara)
0
5
MIN / MAX
/
/
DUST
50
90
(C)
(%)
SHAFT
DIFFUSERS
BOLTING
PERFORMANCE:
FUMES
OTHER
RPM
34
35
IMPELLER TYPE
DRIVER TYPE
36
37
INDUCTION MOTOR
38
OTHER
GEAR
STEAM TURBINE
39
MOTOR DRIVER (6.1.1 / 6.1.4)
40
41
33
S6
MANUFACTURER
MAX.
MIN.
RATED POWER
(kW) EFFICIENCY
STABLE
(mm)
(%)
3
(m /h)
TO
TO
(m 3/h)
(m 3/h)
42
(kW)
(RPM)
ENCLOSURE
43
FRAME
44
HORIZONTAL
45
VOLTS/PHASE/HERTZ
46
TYPE
47
48
INSULATION
49
50
DRIVERS
51
STARTING METHOD
CONTROL
52
LUBE
VERTICAL
(m)
(kW)
SERVICE FACTOR
(m) (5.1.10)
12,800 SI Units
85 @ 1.0 m
TEMP. RISE
ELECTRICITY
(5.1.11)
(dBA) (5.1.16)
(dBA) (5.1.16)
(dBA) (5.1.16)
VOLTAGE
PHASE
HERTZ
415 V
240 V
3 ph
1 ph
50
50
OTHER
80%
(6.1.5)
53
54 BEARINGS (TYPE/NUMBER):
STEAM
55
RADIAL
56
THRUST
57
58
UP
(N)
MAX. PRESS.
HEATING
59
(N)
SUPPLY TEMP.
NORM. PRESS.
60
61
MIN. PRESS.
MIN. TEMP.
N/A
N/A
DRIVERS
COOLING WATER:
DOWN
MAX. TEMP.
(5.1.19) SOURCE
VTS
VTS
VTS
(C)
YES
(barg)
DESIGN PRESS.
(barg)
VTS
VTS
VTS
CHLORIDE CONCENTRATION:
(C)
(barg)
(barg)
(PPM)
62
63
64
65
66
14-May-10
SCW
SH
KMNP
Rev.
Date
Issue Description
Originated
Checked
Approved
Client
435/JH0911
Datasheet No:
435-JH0911-10-ME-DAS-0005-001
SHEET
1
of
Client:
Hindustan Petroleum Corporation Limited
Plant Location:
ONGC, Hazira
Supplier:
Purchase Order No.:
LPG
Service Description:
CONSTRUCTION
CW
CCW
MANUFACTURER'S STANDARD
BB1
BB2
BB3
Other
BB5
PUMP:
5 CASING MOUNTING:
6
CENTERLINE
FOOT
PRIMER
FINISH COAT
8 CASING SPLIT
9
BASEPLATE: (6.3.17)
AXIAL
RADIAL
10 CASING TYPE:
PRIMER
11
SINGLE VOLUTE
12
BETWEEN BEARINGS
MULTIPLE VOLUTE
DIFFUSER
FINISH COAT
BARREL
SHIPMENT: (7.4.1)
14
15
(barg)
(C)
DOMESTIC
EXPORT
(barg)
16
HYDROTEST PRESSURE
SUCTION PRESSURE REGIONS MUST BE DESIGNED
18
19
20
SIZE
21
17
FAC'G
POSITION
23 DISCHARGE
COOLING REQ'D.
300#
300#
22 SUCTION
C.W. PIPING:
PIPE
24 BAL. DRUM
25
TUBING;
FITTINGS
26
S. STEEL
27
DRAIN
BEARING HOUSING
(m /h) @
28
VENT
HEAT EXCHANGER
(m /h) @
29
PRESSURE GAUGE
30
TEMP. GAUGE
31
WARM-UP
32
BALANCE/LEAK-OFF
33
RADIAL
34
THRUST
TYPE
STEAM PIPING:
GALVANIZED
TUBING
(bar)
(bar)
PIPE
35 ROTOR:
36
37
RING OIL
PURGE OIL
39
MANUFACTURER
40
41
SPACER LENGTH
42
HYDRODYNAMIC
38 COUPLINGS:(6.2.2)
43
C. STEEL
MODEL
(mm)
DRIVER MFR.
SERVICE FACT.
1.5
PURCHASER
STEAM
INSTRUMENTATION (6.4.2)
44
45
46
47
RADIAL
48
49
50
PER BRG
ELECTRIC
AXIAL
PER BRG
51 BASEPLATES:
52
53
54
OTHER
(ANNEX D)
55 MECHANICAL SEAL:(5.8.1)
Remark-4 & 5
56
57
VENDOR SHALL FURNISH DULY FILLED IN API682 DATA SHEET WITH BID
MASSES (kg)
58
59
PUMP
BASEPLATE
60
DRIVER
COUPLING
61
GEAR
TOTAL
62
63
64
65
66
Hindustan Petroleum Corporation LimitedCLIENT
HPCL
Project No:
Datasheet No:
435/JH0911
435-JH0911-10-ME-DAS-0005-001
SHEET
2
of
Client:
Hindustan Petroleum Corporation Limited
Plant Location:
ONGC, Hazira
Supplier:
Purchase Order No.:
LPG
Service Description:
1
2
START-UP
SPECIFY
NORMAL MAINTENANCE
NON-WIT
NPSH (7.3.4.2)
(REMARK 1)
10
11
CLEANLINESS PRIOR TO
12
13
14
15
16
17
18
19
20
21
VENT
DRAIN
22
(7.3.3.4d)
23
24 CONNECTION BOLTING
TEST (7.3.4.6)
25
PTFE COATING
REMOVE / INSPECT
26
6
PAINTED
SS
HYDRODYNAMIC
O
C BEARINGS
GS
28
29
TEST (7.3.4.5)
30
31
32
33
CASING
34
OTHER
IMPELLER
AUXILIARY EQUIPMENT
Remark-14
SHAFT
35
36
37
MAG PARTICLE
LIQUID PENETRANT
38
RADIOGRAPHIC
ULTRASONIC
39
OBSERVE
HYDROSTATIC (7.3.2)
PERFORMANCE (7.3.3)
27
Remark-7
WIT
40
MAG PARTICLE
LIQUID PENETRANT
41
RADIOGRAPHIC
ULTRASONIC
42
43
44
FOR
45
METHOD
(7.2.2.3)
Shaft
Ultrasonic
46
47
REMARKS
48
49
50
51
52
53
54
55
55
56
57
58
59
60
61
62
63
64
65
Hindustan Petroleum Corporation LimitedCLIENT
HPCL
Project No:
Datasheet No:
435/JH0911
435-JH0911-10-ME-DAS-0005-001
SHEET
3
of
Client:
Hindustan Petroleum Corporation Limited
Plant Location:
ONGC, Hazira
Supplier:
Purchase Order No.:
LPG
Centrifugal Pump Data Sheet to API 610, 10th Edition
1 APPLICABLE TO:
PROPOSALS
PURCHASE
AS BUILT
ONGC, Hazira
2 FOR
HPCL
UNIT
3 SITE
SERVICE LPG
4
5 NOTES: INFORMATION BELOW TO BE COMPLETED:
BY PURCHASER
BY MANUFACTURER
BY MANUFACTURER OR PURCHASER
6
7 PRESSURE VESSEL DESIGN CODE REFERENCES.
8
9
10
11
12
13 WELDING AND REPAIRS (5.12.3.1)
14
THESE REFERENCES MUST BE LISTED BY THE PURCHASER. (DEFAULT TO TABLE 10 IF NO PURCHASER PREFERENCE IS STATED)
15
16
17
Purchaser defined
Welder/operator qualification
18
19
20
21
22
23
24 MATERIAL INSPECTION (7.2.2.1)(7.2.1.3)
25
26
27 Type of inspection
28
Radiography
29
Ultrasonic inspection
30
31
Methods
For fabrications
Castings
REMARKS
32
33 1. The rated differential pressure specified for the pump has been arrived at based on the highest product density.
34 2. Pump shall be suitably selected for all operating conditions and fluids properties specified. Any short comings shall be highlighted in the Bid. Characteristic curves
35
for various operating speeds indicating operating points shall be provided with Bid for Purchaser review during bid evaluation.
indicating all accessories and instrumentation and connection details. Vendor shall provide complete information for the sealing systems offered along with the bid.
39 5. Double mechanical seal shall be offered and shall be as per API 682. The seal plans shall be selected and approved by seal vendor for the present application. Vendor to
40
consider plan 52 for secondary seal. Vendor to provide the emmission data from the seal/seal-pot that needs to be vented, and provide recommendations on the same.
41 6. Inspection and testing requirement shall be firmed up during vendor bid evaluation stage. Vendor shall furnish preliminary Inspection and Test Plan with the bid.
42 7. The trip speed should be limited to 105%
43
44 8. Vendor to consider Automatic Minimum Recirculation Valve for each pump, as a free issue, to installed by others. Vendor to select the valve suitable for stable
45
46
47
48
49
50
51
minimum continuous recirculation flow of his pumps and shall provide the selection basis and valve vendor data sheet along with the bid.
The Automatic Minimum Recirculation Valve shall be complete and shall be from a reputed manufacturer such as Schroedahl / Yarway / equivalent, and shall be selected
such that there is minimum possible pressure drop across the main flow direction for the pump rated flow. Vendor to add this pressure drop to the specified differential
head of the pump to arrive at the final pump differential head to be offered -- vendor to clearly identify the same in their bid.
The valve shall be rated for the pump discharge flange rating. Vendor to also indicate the maximum distance the valve can be located from the pump discharge.
9. Vendor to note that there is no cooling water vailable in the plant. Hence any cooling requirement shall be met by air cooling. (Hold)
10. Deleted
52
53
54 11. Deleted
55
56
57 12. Deleted
58
59 13. Deleted
60
61 14. Site Acceptance Testing (SAT) of each pump along with its motor,and other auxillaries shall be carried out by vendor at site for final acceptance by Purchaser.
Vendor to provide a typical test plan for same along with the bid for Purchaser's evaluation, however should include 48 hours run test at rated point (or guarantee point)
The entire pump, motor and auxillaries shall perform satisfactorily during the test and
64
meet all the guarantee parameters. Any additional testng instrumentation, etc required shall be adviced by vendor in the bid.
65 15. For trip signal: refer note 8 of process data sheet
62
63
66
Hindustan Petroleum Corporation LimitedCLIENT
HPCL
Project No:
Datasheet No:
435/JH0911
435-JH0911-10-ME-DAS-0005-001
SHEET
4
of