You are on page 1of 12

HVAC CAMP MAINTENANCE

LONG YEAR MAINTENANCE PLAN


(MUBARRAZ)
Rev Tuesday, March 12, 2013
ITEM
DESCRIPTION
WATER CHILLER UNIT
A

(COMPRESSOR/PUMP MOTOR)
TOTAL: 15 (Before)
TOTAL: 18 (Now)

CONDENSER
B

TOTAL: 25 (Before)
TOTAL: 34 (Now)

PACKAGE A/C UNIT


C
D

(AIR-COOLED)
TOTAL: 10 (Now)
AIR HANDLING UNIT
TOTAL: 6 (Now)
FAN COIL UNIT UNITS )
TOTAL: 529 (Before)
TOTAL: 553 (Now)

LOCATION
ACCOM. A & B
(NEW CHILLER)
CNIA-MAIN
GH
SPC
MCR
ACCOM. A & B
(NEW CHILLER)
CNIA-MAIN
GH
SPC
MCR
POWER HOUSE
MOSQUE
WEST MUB
SR & JR MESS-KITCHEN /
MULTI-PURPOSE
A-CAMP
B-CAMP
C-CAMP
CNIA (MAIN)
CNIA (GH)
CNIA (SPC)
MCR/POWER HOUSE CONTROL ROOM
LABORATORY
ADOC OFFICE
MULTI-PURPOSE (OFFICE/STORE)
SR & JR MESS-KITCHEN
MCC ROOM/CHILLER ROOM/BOILER

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx/LYMP

YEAR
2002/2003
(2012 Additional Units)
2002/2003
2002/2003
2003
2002
2002/2003
(2012 Additional Units)
2002/2003
2002/2003
2003
2002
2004
2004
2004
1998
1998
2004/2007/2008/2009
2002/2003/2004/2005 / 2012
2006 (2012 Bldg Remodeling)
2002/2003/2004
1998 (2011 Renewed)
1998 (2011 Renewed)
2006/2007
2000 (2011 Renewed)
1998/2007/2008 (2012 Renewed)
2006
2001/ 2012
2002/2008 / 2011/2012

QTY
5
3
4
2
2
2
15
9
4
2
2
2
4
2
4
4
2
76
164
131
48
15
15
20
9
27
4
12
32

MAINTENANCE

OVERHAULING

REPLACEMENT

MONTHLY

5 YEARS

12 YEARS

MONTHLY

8 YEARS

5 YEARS

10 YEARS
12 YEARS
8 YEARS

MONTHLY
MONTHLY

7 YEARS

15 YEARS

QUARTERLY

3 YEARS

10 YEARS

REMARKS

Due to environmental conditions.


2005 Coil Replaced
2005 Overhauled

1/12

HVAC CAMP MAINTENANCE


LONG YEAR MAINTENANCE PLAN
(MUBARRAZ)
Rev

Tuesday, March 12, 2013


SPLIT TYPE A/C UNIT
1-PHASE / 220 VOLTS
TOTAL: 256 (Before)
TOTAL: 272 (Now)
(Including Rental Units-6)

WINDOW A/C
TOTAL: 55 (Before)
TOTAL: 101 (Now)
(Including Rental Units-36)
G

COLD STORE

WATER
WATER
WATER
WATER

HEATER (OLD)
HEATER (NEW)
HEATER
HEATER

TOTAL: 22 (Before)
TOTAL: 27 (Now)
(6 KW ~ 75 KW)
PANEL AC
J

TOTAL: 5 (Before)
TOTAL: 8 (Now)

WORKSHOP & SEATRAINS


WAREHOUSE & HELIPORT
CIVIL & FALAHI
MARINE / FIRE STATION / PABX
R. O. PLANT
CNIA MAIN (Outpost, Comm. Twr)
CNIA/GH (Room-Store-Gym)
CNIA (SPC)
CNIA (OFFICES & MESS)
D-CAMP
CARPENTRY
POWER HOUSE (MG-1~ MG-8)
NEW MINERAL STORE
NEW CNIA MCC ROOM
HV DISCONNECTION ENCLOSURE
AMINE UNIT (MCC ROOM)
NEW COMP (LCP-010 A/B)
NEW COMP (LCP-300TF)
INCINERATOR MCC ROOM
OPEN YARD (WORKSHOP & SITE OFF)
MOSQUE (IFTAR)
WEST MUBARRAZ (Plant, CNIA. GA Term)
NEW PAINT STORE
CNIA MAIN (Caravan/Outpost)
D-CAMP
R. O. PLANT
PAINT YARD & STORE
MARINE & MULTI PURPOSE TOILET
FIRE PUMP HOUSE
INCINERATOR REST ROOM & SITE OFF
POWER HOUSE -CARAVAN W/SHOP
MUBARRAZ STORES
WEST MUBARRAZ (Plant, CNIA)
RENTAL CARAVANS
MEAT FREEZER
VEG. CHILLER
A & B CAMP
C-CAMP
WEST MUBARRAZ
CNIA (MAIN)
CNIA (GH)
CNIA (SPC)
WEST MUBARRAZ
MUBARRAZ

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx/LYMP

2008/2010
2006/2009
2009
2009/2010
2008/2009
2006/2009
2009
2009
2009/2012
2006
2008
2008
2009
2010
2008
2006/2011
2010
2011
2008
2008/2004
2012
2002
2012/2013
2008
2002
2007
2004
2008
2009
2008
2007
2002
2002
2008/2012
2002
2002
1998
2011 (Additional Units)
2006/2009
2002/2011
2009
1998
1998
1998/2005
2006/2011

36
20
10
13
3
12
18
16
31
1
4
24
2
4
5
8
2
1
1
9
2
47
3
8
20
2
2
2
1
7
2
4
17
36
2
2
2
2
6
2
6
3
6
5
3

Minimum of 3 years due to


unit breakdown (e.g. system leak,
electronic controls failure).

R-22/R407C/R410A
R-22
R-22
R-22

MONTHLY

5 YEARS

Minimum of 1-1/2 years due to


early breakdown (e.g. units are
modified to Mubarraz refrigerant
usage, leaks & motor failures).
MONTHLY

3 YEARS

MONTHLY

5 YEARS

10 YEARS

ANNUALLY

1 YEAR

X
X
X
X
X
COMP (S/D)
COMP (S/D)

2 YEARS
3 YEARS
3 YEARS
3 YEARS
3 YEARS
12 YEARS
5 YEARS

ANNUALLY

MONTHLY
MONTHLY

Poor quality AC (C-010 A/B)


2/12

HVAC CAMP MAINTENANCE

(LONG YEAR MAINTENANCE PLAN


MUBARRAZ - ADOC
As of Tuesday, September 25, 2012
ITEM

LOCATION

QUANTITY
(PRESENT)

DATE

2002

2003

2004

2005

2006

2007

LIQUID CHILLER UNIT

NEW ACCOM - CHILLER NO. 1

Jan-02

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER NO. 2

Jan-02

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER NO. 3

Dec-02

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER NO. 4

Jan-03

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER NO. 5

Oct-03

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER NO. 6 (NEW UNIT)

10 UNITS

2012

NEW ACCOM - CHILLER NO. 7 (NEW UNIT)

2012

NEW ACCOM - CHILLER NO. 8 (NEW UNIT)

2012

MCR/LAB - CHILLER NO. 1

Jan-02

COMP O/H (5 YRS)

REPLACED (w/ new refrigerant)

(CONDENSER COIL/UNITARY)

COND. COIL REPLACED

MCR/LAB - CHILLER NO. 2

Jan-02

REPLACED (w/ new refrigerant)

NEW ACCOM - CHILLER COND NO. 1-A/B/C

Jan-02

REPLACED

NEW ACCOM - CHILLER COND NO. 2-A/B/C

Jan-02

REPLACED

NEW ACCOM - CHILLER COND NO. 3-A/B/C

Dec-02

REPLACED

COMP O/H (5 YRS)

(CONDENSER COIL/UNITARY)

CONDENSER

NEW ACCOM - CHILLER COND NO. 4-A/B/C

24 UNITS

NEW ACCOM - CHILLER COND NO. 5-A/B/C

Jan-03

REPLACED

Oct-03

REPLACED

NEW ACCOM - CHILLER COND NO. 6-A/B/C (NEW UNIT)


NEW ACCOM - CHILLER COND NO. 7-A/B/C (NEW UNIT)
NEW ACCOM - CHILLER COND NO. 8-A/B/C (NEW UNIT)

PACKAGE A/C UNIT


POWER HOUSE AIR-COOLED NO.1

Jan-04

REPLACED (w/ new refrigerant)

POWER HOUSE AHU NO.1


POWER HOUSE AIR-COOLED NO.2

Nov-07

RE-INSTALLED

POWER HOUSE AHU NO.2

POWER HOUSE AIR-COOLED NO.3


POWER HOUSE AHU NO.3
POWER HOUSE AIR-COOLED NO.4

6 UNITS

Jul-04

REPLACED (w/ new refrigerant)

Feb-04

REPLACED (w/ new refrigerant)

POWER HOUSE AHU NO.4


MOSQUE AIR-COOLED NO.1

Dec-04
REPLACED (w/ new refrigerant)

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

3 / 12

MOSQUE AIR-COOLED NO.2

Dec-04

MOSQUE AIR HANDLING UNIT

Dec-04

REPLACED (w/ new refrigerant)

AIR HANDLING UNIT

SENIOR KITCHEN - AHU NO. 1

1998

OVERHAULED

COIL REPLACED

JUNIOR KITCHEN - AHU NO. 2

1998

OVERHAULED

COIL REPLACED

1998

OVERHAULED

COIL REPLACED

JUNIOR MESS - AHU NO. 4

1998

OVERHAULED

COIL REPLACED

OLD A-CAMP / MULTI-PURPOSE - AHU NO.1

1998

OVERHAULED

RECONDITIONED

RE-COMISSIONED

OLD A-CAMP / MULTI-PURPOSE - AHU NO.2

1998

OVERHAULED

RECONDITIONED

RE-COMISSIONED

SENIOR MESS - AHU NO. 3

6 UNITS

MUBARRAZ A/C UNITS

(LONG YEAR MAINTENANCE PLAN

ITEM

LOCATION

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

QUANTITY

DATE

2002

2003

2004

2005

2006

2007
4 / 12

ITEM

LOCATION

(PRESENT)

DATE

2002

2003

2004

2005

2006

2007

FAN COIL UNIT / (PREVIOUS - 443 UNITS)

ADOC OFFICE (27 UNITS)

1998

NEW A-CAMP (76 UNITS)

1998

NEW B-CAMP (164 UNITS)

1998

NEW C-CAMP (131 UNITS)

471 UNITS

REPLACED (7 UNITS)
4 UNITS (REPLACED)
REPLACED (18 UNITS)

53 UNITS (REPLACED)

39 UNITS (REPLACED)

REPLACED (35 UNITS)


38 UNITS (REPLACED)

1998

SR & JUNIOR KITCHEN / AHU RM (12 UNITS)

1998

MCR BLDG/STORE (19 UNITS)

1998

LAB BLDG (9 UNITS)

1998

CHILLER ROOM/MULTI PURPOSE/ELECT RM (33 UNITS)

1998

NEW UNITS
4 UNITS (NEW)

NEW (4 UNITS)

REPLACED (4 UNITS)

9 UNITS (REPLACED)

SPLIT TYPE A/C UNIT 1 PHASE / (PREVIOUS - 121 UNITS)


F

W/SHOP-P/HOUSE/MCR AREA/SITE OFF/ELECT/CNIA

264 UNITS

2002

REPLACED (31 UNITS)

5 UNITS (REPLACED)

2003

WINDOW A/C (PREVIOUS - 31 UNITS)


W/SHOP-P/HOUSE/D-CAMP/SITE OFF/ELECT

36 UNITS

COLD STORE
FREEZER (MEAT) NO.1

FREEZER (MEAT) NO.2

4 UNITS

Feb-02

REPLACED (New Refrigerant)

COMPRESSOR (REPLACED)

Sep-02

REPLACED (New Refrigerant)

COMPRESSOR (REPLACED)

CHILLER (VEG) NO.1

Aug-05

REPLACED (New Refrigerant)

CHILLER (VEG) NO.2

Jul-05

REPLACED (New Refrigerant)

WATER BOILER A & B CAMP


1998

BOILER NO.1

BOILER NO.2

4 UNITS

OVERHAULED

OVERHAULED

OVERHAULED

1998

BOILER NO.3

2011

BOILER NO.4

2011

WATER BOILER C - CAMP

BOILER NO.1

2006

COMMISSIONED

BAD CONDITION (Internal)

BOILER NO.2

2006

COMMISSIONED

BAD CONDITION (Internal)

2006

COMMISSIONED

BAD CONDITION (Internal)

BOILER NO.4

2006

COMMISSIONED

BAD CONDITION (Internal)

BOILER NO.5

2006

COMMISSIONED

BAD CONDITION (Internal)

BOILER NO.6

2006

COMMISSIONED

BAD CONDITION (Internal)

BOILER NO.3

6 UNITS

PANEL A/C
K

C-010 A/B

3 UNITS

C-300 TF

2006

OVERHAULED

2011

SEWAGE PUMPS

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

20 UNITS

5 / 12

INTENANCE

TENANCE PLAN)
- ADOC

2008

2009

2010

2011

2012

2013

2014

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

REMARKS

OVERHAULED (JULY)

YEAR 2015 (REPLACEMENT)

OVERHAULED (JULY)

YEAR 2015 (REPLACEMENT)

ADDITIONAL UNIT
ADDITIONAL UNIT
ADDITIONAL UNIT
REPLACE UNIT (12 YRS)

REPLACE UNIT (12 YRS)


REPLACEMENT

REPLACEMENT

REPLACEMENT (12 YRS)

DEPENDS ON CONDITION (Outdoor Unit)

REPLACEMENT

REPLACEMENT (12 YRS)

DEPENDS ON CONDITION (Outdoor Unit)

REPLACEMENT (12 YRS)

DEPENDS ON CONDITION (Outdoor Unit)

REPLACED (NOV)
REPLACED (OCT~NOV)

YEAR 2015 (REPLACEMENT)


REPLACEMENT

YEAR 2015 (REPLACEMENT)

ADDITIONAL UNIT
ADDITIONAL UNIT
ADDITIONAL UNIT

OVERHAULED (OCT)

REPLACEMENT

OVERHAULED (OCT)

10 YEARS PLAN
DEPENDS ON CONDITION (Outdoor Unit)

REPLACEMENT

10 YEARS PLAN
DEPENDS ON CONDITION (Outdoor Unit)

OVERHAULED (OCT)

REPLACEMENT

OVERHAULED (OCT)

DEPENDS ON CONDITION (Outdoor Unit)

OVERHAULED (OCT)

REPLACEMENT

OVERHAULED (OCT)
OVERHAULING

10 YEARS PLAN
DEPENDS ON CONDITION (Outdoor Unit)

OVERHAULED (JAN 2012)


REPLACEMENT

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

10 YEARS PLAN

YEAR 2016
6 / 12

REPLACEMENT

OVERHAULING

OVERHAULED (JAN 2012)

OVERHAULING

OVERHAULED (JAN 2012)

OVERHAULING

OVERHAULED (MAY 2012)

REPLACEMENT

OVERHAULING

OVERHAULED (MAY 2012)

REPLACEMENT

OVERHAULING

OVERHAULED (APR 2012)

REPLACEMENT

OVERHAULING

OVERHAULED (MAY 2012)

REPLACEMENT

YEAR 2016

15 YEARS PLAN

OVERHAULING
OVERHAULING

/C UNITS

TENANCE PLAN)

2008

2009

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

2010

2011

2012

2013

2014

REMARKS
7 / 12

2008

2009

2010

2011

4 UNITS (REPLACED)
11 UNITS (REPLACED)

21 UNITS (REPLACED)
2 UNITS (REPLACED)

2012

2013

2014

REMARKS

REPLACED 21 UNITS (JAN)

10 UNITS (OLD)

REPLACED 7 UNITS (MAR)

9 UNITS (STORE/LAUNDRY)

REPLACEMENT (50 UNITS)

REPLACEMENT (55 UNITS)

5 UNITS (RECREATION/SATELLITE)

Modification (Contractor) January


REPLACED (6 UNITS)
OVERHAULING
REPLACED (9 UNITS)

46 UNITS (REPLACED)

34 UNITS (REPLACED)

8 UNITS (ADDITIONAL)

REPLACED (4 UNITS)

9 UNITS (REPLACED)

REPLACEMENT (40 UNITS)


(AMINE REPLACED-JAN/FEB)

REPLACEMENT

COND COIL (REPLACED)

OVERHAULING OF MOTORS

COND COIL (REPLACED)

OVERHAULING OF MOTORS
OVERHAULING OF MOTORS
OVERHAULING OF MOTORS

OVERHAULED

OVERHAULED

OVERHAULED/MODIF (FEB-MAR)
OVERHAULED/MODIF (AUG)

OVERHAULING
OVERHAULING

COMMISSIONED (JUNE)
COMMISSIONED (JUNE)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

MAINTENANCE

UNIT REPLACED

REPLACEMENT (BLDG REMODELING)

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

8 / 12

HVAC CAMP MAINTENANCE


(LONG YEAR MAINTENANCE PLAN)
MUBARRAZ - CNIA
As of Tuesday, September 25, 2012
ITEM

LOCATION

QUANTITY
(PRESENT)

DATE

2002

2003

2004

2005

2006

2007

2008

2009

2010

2011

2012

2013

2014

REMARKS

LIQUID CHILLER UNIT

CNIA ACCOM (MAIN) - CHILLER NO. 1

Jan-02

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

CNIA ACCOM (MAIN) - CHILLER NO. 2

Jan-02

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

CNIA ACCOM (MAIN) - CHILLER NO. 3

Dec-02

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

CNIA ACCOM (MAIN) - CHILLER NO. 4

Jan-03

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT

YEAR 2015

CNIA ACCOM (GH) - CHILLER NO. 1

Oct-03

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT

YEAR 2015

CNIA ACCOM (GH) - CHILLER NO. 2

Sep-03

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT

YEAR 2015

CNIA ACCOM (SPC) - CHILLER NO. 1

Sep-03

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT

YEAR 2015

CNIA ACCOM (SPC) - CHILLER NO. 2

Jan-02

8 UNITS

REPLACED (w/ new refrigerant)

COMP O/H (5 YRS)

REPLACEMENT (12 YRS)

CONDENSER

CNIA (MAIN) - CHILLER COND NO. 1

Sep-03

REPLACED

REPLACED (OCT)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

CNIA (MAIN) - CHILLER COND NO. 2

Sep-03

REPLACED

REPLACED (SEPT)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

CNIA (MAIN) - CHILLER COND NO. 3

Jan-02

REPLACED

REPLACED (SEPT)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

CNIA (MAIN) - CHILLER COND NO. 4

Jan-02

REPLACED

REPLACED (AUG)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

REPLACED (NOV)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

REPLACED (NOV)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

8 UNITS

CNIA (GH) - CHILLER COND NO. 1

Jan-03

CNIA (GH) - CHILLER COND NO. 2

Nov-02

CNIA (SPC) - CHILLER COND NO. 1

Sep-03

REPLACED

REPLACED (NOV)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

CNIA (SPC) - CHILLER COND NO. 2

Oct-03

REPLACED

REPLACED (NOV)

REPLACEMENT

DEPENDS ON CONDITION (Outdoor Unit)

REPLACED
REPLACED

FAN COIL UNIT (PREVIOUS - 87 UNITS)


1998

CNIA - MAIN (48 UNITS)

REPLACED (28 UNITS)

13 UNITS (REPLACED)

2 UNITS (REPLACED)

1 UNIT (Additional)

1 UNIT (Additional) - O/H

OVERHAULING

1998

REPLACED (JUNE)

YEAR 2016 (OVERHAULING)

CNIA - SPC (15 UNITS)

1998

REPLACED (MAY)

YEAR 2016 (OVERHAULING)

CHILLER ROOM (4 UNITS)

1998

CNIA - GUEST HOUSE (15 UNITS)

82 UNITS

SPLIT TYPE A/C (PREVIOUS - 5 UNITS)


CNIA MAIN BLDG

(ROOM/STORE/ARMORY/OUTPOST)
CNIA (NEW BUILDINGS / JAIL / NEW ROOM/LAUNDRY)
REFRIGERANT-22

10 UNITS

1 UNIT (REPLACED)

1 UNIT (REPLACED)

REPLACED/ADDITIONAL (OCT)

(Police Major Room)

(Police Capt Room)

(Room/Armory/Store/Outpost)

REPLACEMENT (2 UNITS)

RENEWAL

RENEWAL

65 UNITS 2009
65 UNITS (New Installation)

ALL UNITS (R-22) INSTALLED IN 2006


BREAKS DOWN IN LESS THAN 2 YEARS.

REPLACEMENT (New Refrigerant)

WINDOW A/C (PREVIOUS - 7 UNITS)


ACCOM/STORE/LAUNDRY ROOM

6 UNITS

WATER HEATER

CNIA (MAIN) HEATER NO.1

1998

OVERHAULED

REPLACED

O/H-MODIF (MAR)

REPLACEMENT

CNIA (MAIN) HEATER NO.2

1998

OVERHAULED

REPLACED

RECONDITIONED (FEB)

REPLACEMENT

CNIA (MAIN) HEATER NO.3

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACED (APR)

REPLACEMENT

CNIA (MAIN) HEATER NO.4

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

REPLACEMENT

CNIA (MAIN) HEATER NO.5

1998

OVERHAULED

REPLACED

REPLACED (FEB)

REPLACEMENT

CNIA (MAIN) HEATER NO.6 (COMMON BATHROOM)

2012

ADDITIONAL (FEB)

REPLACEMENT

CNIA (MAIN) HEATER NO.7 (TEA ROOM/TOILET)

2012

REPLACEMENT (FEB)

REPLACEMENT

CNIA (GH) HEATER NO.1


CNIA (GH) HEATER NO.2

14 UNITS

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (GH) HEATER NO.3


CNIA (SPC) HEATER NO.1

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (SPC) HEATER NO.2

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (SPC) HEATER NO.3

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (SPC) HEATER NO.4

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (SPC) HEATER NO.5

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

CNIA (SPC) HEATER NO.6

1998

OVERHAULED

ELEMENT REPLACED

REPLACED

REPLACEMENT

331059970.xlsx / Mub_CNIA

HVAC CAMP MAINTENANCE


(LONG YEAR MAINTENANCE PLAN)
WEST MUBARRAZ - ADOC
As of Tuesday, September 25, 2012
ITEM

LOCATION

QUANTITY
(PRESENT)

DATE

2002

2003

2004

2005

2006

2007

2008

2009

2010

2011

2012

REPLACEMENT (4 UNITS)

2013 2014

REMARKS

PACKAGE A/C UNIT


Dec-03

SCR / MCC ROOM AIR-COOLED NO.1

SCR / MCC ROOM AIR-COOLED NO.2

SCR / MCC ROOM AIR-COOLED NO.3

COMMISSIONED

Nov-03

COMMISSIONED

Jul-04

COMMISSIONED

Nov-03

SCR / DCS ROOM AIR-COOLED NO.4

COMP (Replaced)

COMP/COND (Leaked)

REPLACED (JAN-FEB)

8 YEARS PLAN

(Early Replacement is due

REPLACED (JAN-FEB)

(Due to Environtal

to a bad condition and

REPLACED (JAN-FEB)

Condition)

frequent breakdown)

COMMISSIONED

REPLACED (AUG)

SPLIT TYPE A/C UNIT (PREVIOUS - 44 UNITS)


MESS HALL (4 UNITS)

4 UNITS (REPLACED)

SCR/HALON ROOM (9 UNITS)

4 UNITS (REPLACED)

4 UNITS (REPLACED)

4 UNITS (REPLACED)

CARAVAN/WORKSHOP/NDT/N2 (6 UNITS)
SGIP MCC ROOM (6 UNITS)

46

4 UNITS (REPLACED)

REPLACED (1 UNIT)

4 UNITS (REPLACED)

REPLACED (2 UNITS)

6 UNITS (REPLACED)

HV ENCLOSURE (5 UNITS)

for Locally Made


5 UNITS (ADDITIONAL)

Equipment)
REPLACEMENT (7 UNITS)

NEW PAINT STORE


G. A. TERMINAL (6 UNITS)

5 YEARS PLAN

6 UNITS (REPLACED)

NEW INSTALLATION

6 UNITS (REPLACED)

WINDOW A/C ( 15 UNITS )


CARAVAN/HALON/N2/STORE/TOILET

12

REPLACEMENT (10 UNITS)

Locally Made

SGIP PANEL A/C


1998

C-100

C-200
C-700

C-800

WATER HEATER - (PREVIOUS - 2 UNITS)

Manny
file:///var/www/apps/conversion/tmp/scratch_1/331059970.xlsx

REPLACED (MAY)

1998

REPLACED (SEPT)

1998

WAITING FOR S/D

1998

REPLACED (JULY)

Dec-05

C-900

OVERHAULED

2002 / 2011

REPLACED (MAR)

10 / 12

HVAC CAMP MAINTENANCE

(LONG YEAR MAINTENANCE PLAN)


WESR MUBARRAZ - CNIA
As of Tuesday, September 25, 2012
ITEM

LOCATION

QUANTITY
(PRESENT)

DATE

2002

2003

2004

2005

2006

2007

SPLIT TYPE A/C UNIT 1 PHASE (PREVIOUS - 6 UNITS)


A

CNIA ACCOMMODATION

7 UNITS

6 UNIT (REPLACED)

6 UNIT (REPLACED)

(Local Made/R407C)

(HITACHI-R410A)

CNIA OUTPOST

1 UNIT (New Installation)

WINDOW A/C (PREVIOUS - 1 UNIT)


B

(OUTPOST) - 1 UNIT

3 UNITS

2002

REPLACED

REPLACED

(MOSQUE) - 2 UNITS

WATER HEATER
(CNIA ACCOM) HEATER

331059970.xlsx / W-Mub_CNIA

1 UNIT

2002

ELEMENT REPLACED

REPLACED

NTENANCE

ENANCE PLAN)

AZ - CNIA

2008

2009

2010

2011

2012

2013

2014

REMARKS

YEAR 2016 (REPLACEMENT)

REPLACED (JULY)

YEAR 2016 (REPLACEMENT)


YEAR 2016 (REPLACEMENT)

NEW INSTALLATION

REPLACEMENT

REPLACEMENT

REPLACEMENT

REPLACEMENT

REPLACED (MAR)

331059970.xlsx / W-Mub_CNIA

You might also like