ull connected world cannot build without network, power supply


become a key factor in network reliability. Along rapid development of
telecommunication industry, site number tends to be explosive and the

growth rate of energy cost exceeds increase of income. Low energy efficiency
and weak expansion ability of traditional site hardly meets requirements of
building a green broadband network and reducing operational cost. How to
effectively deploy sites, elevate energy efficiency and reduce carbon emissions
while improving the power supply and environment assurance reliability, has
become common challenges faced by enterprises and operators globally.

uawei, with extensive experiences in digital technology, network


technology, M2M, software, big data, and power electronics, is
promoting legacy telecom power onto a new level, where energy

can be accessed anytime, anywhere, energy utilization becomes simpler, energy


management becomes smarter and energy facility is always ready to facilitate
network evolution. MTS (Migrate Towards Simplicity) makes everything simple,
ensures more efficient network and operation. Let's build a better connected
world, together.

Contents
Large Capacity Power System
100A-24,000A/6kW-1,440kW

Indoor Power System


100A-600A/6kW-36kW

Outdoor Power System


100A-400A/6kW-24kW

Wall-mounted Power System


30A-60A/1.74kW-3.2kW

Embedded Power System


30A-400A/1.74kW-24kW

Monitoring Modules
SUM02B/ECC500

Rectifier Modules
15A-100A/870W-6,000W

Advanced Energy Storage Modules


ESM-A2400Wh(D)/ESM-A9600Wh(N)

Large capacity power


(100A-24,000A)

Wall-mounted power
(30A-60A)

Indoor power
(100A-600A)

Outdoor power
(100A-400A)

Embedded power
(30A-400A)

New Generation Outdoor Solution


MTS9000A

PowerCube 1000 - Solar Hybrid


PowerCube S1/S2/S3

PowerCube 1000 - Diesel Hybrid


PowerCube D1-Standard/D1-Advanced

PowerCube 1000 - Grid Hybrid


PowerCube G2/G3/G4/G4-Mini

PowerCube 500
IVS Solution

Energy OSS
NetEco

MTS9000A

Grid Hybrid

Solar Hybrid

IVS Solution

Diesel Hybrid

NetEco

Large Capacity Power System


100A-24,000A/6kW-1,440kW
Introduction
Huawei new generation all-digital large capacity power systems
include TP483000D, TP482000B and TP481200B. Adopting high
power desity design and 1U 100A or 50A high efficiency rectifiers,
single rectiifer cabinet can output maximum 3000A/180kw. The
systems have tremendous features such as high reliability, high
efficiency, high power density, high capacity, low noise and easy
maintenance.

Application Scenarios

TP481200B TP482000B
Integrated Type

TP483000D
Distributed Type

Wireless network central office


Fixed network central office
Large capacity convergence site
Enterprise network central office
Data center
Legacy
power

Reuse AC & DC
distribution

Newly-built scenario

Reuse AC
distribution

All swap

Legacy power system


modernization

Features
Carrier class high reliability, system MTBF over 500,000 hours,
passed over 1000 test items
Green and energy saving, rectifier efficiency over 96%
Compact design, single rectifier cabinet can output maximum
3000A/180kw,which is the highest in industry
Huge system capacity, TP483000D can be expanded to 24,000A
by parallel combination matching network evolution, while
TP482000B expanded to 10000A and TP481200B expanded to
6000A
Flexible remote monitoring mode, saving OPEX
1

Specifications
Integrated large power system
Product style
Dimension
(WDH)
System

Cabling mode
Rated capacity

DC Distribution

Rectifier Module

TP482000B-N20C5

TP482000B-L20B5

600mm600mm2000mm
Top inlet & outlet
1200A(12100A)

2000A(20100A)

2000A(4050A)

220/380VAC, three phase four/five line (L1, L2, L3, PE or L1, L2,
L3, N, PE)

120/208VAC, three phase


four/five line

Input voltage

260VAC-530VAC, rated: 380VAC

90VAC-290VAC,
rated: 208VAC

Input capacity

2150A/3P (MCCB)

2150A/3P (terminal)

2230A/3P (terminal)

Battery branch

2(1000A2) (NT4)

2(1000A2) (NT4)

2(1000A2) (NT4)

Load branch

6500A(NT3), 6160A(NT00),
6100A(NT00)

6500A(NT3), 6160A(NT00),
6100A(NT00)

6500A(NT3), 6160A(NT00),
6100A(NT00)

Input mode

Three phase, 260VAC-530VAC

120V or 240V dual live wire

100A/6000W

50A/3000W

Input mode
AC Distribution

TP4812000B-N20C3

Rated capacity

Distributed large power system


Product style
Cabinet style

AC Distribution
Cabinet

600mm600mm2000mm

Input mode

220/380VAC, three phase four/five line (L1, L2, L3, PE or L1, L2, L3, N, PE)

Input voltage

260VAC-530VAC, rated: 380VAC

Input capacity

1630A/4P (two inputs/manual switchover)

1400A/4P (two inputs/manual switchover)

AC output

6160A/3P (MCCB)
163A/3P (MCB)
132A/3P (MCB)
332A/1P (MCB)

4160A/3P (MCCB)
163A/3P (MCB)
132A/3P (MCB)
332A/1P (MCB)

Cabinet style

TPD48302B-N20B1

Output voltage
Maximum capacity
Battery branch

Rectifier Cabinet

800mm(W)600mm(D)2000mm(H)
42-58VDC, default value: 53.5VDC
3000A/180kW
2(1250A2) (NT4)

Load branch

8500A(NT3), 4400A(NT2), 4200A(NT1), 8160A(NT00), 6100A(NT00)

Cabinet style

TPR48302B-N20C3

Dimensions(WDH)
Rated capacity

TPA38401B-N20B1

Dimension
(WDH)

Dimensions
DC Distribution
Cabinet

TP483000D
TPA38631B-N20B1

TPR48202B-N20C3

600mm600mm2000mm
3000A/180kW(30100A/6kW)

2000A/120kW(20100A/6kW)

Indoor Power System


100A-600A/6kW-36kW
Introduction
The indoor power systems include integrated power(built-in
batteries) and detached power(separated batteries), whose output
range varies from 100A to 600A. The series can accommodate
high efficiency rectifier modules and have outstanding monitoring
functions, and have been applied in multiple indoor scenarios.

Application Scenarios
Indoor site of access network
Indoor site of convergence network
Medium and small capacity central office
Enterprise communication network

TP48300B/TP48600B Mini TP48300B


Combined Type

supporting solar evolution


Unified NetEco

Integrated Power
Mini Power

Detached Power

supporting solar evolution

High temp. battery

Features
High rectifier efficiency (>98%) and non-derating below 55C
help save energy
Footprint saving, 50% footprint saved by integrated power, 0
footprint for rack stack / wall-mounted of mini power
Large housing ability, up to 8 BBUs accommodation
Intelligent battery management prolongs battery lifespan
Support in-band transmission networking, 0 extra data
collector and transmission link cost
All-in-one controller, MIMO* energy scheduling mgmt., 5 AI, 9
DI, 8 DO
Support solar access, saving grid expenditure
High-temp. battery saves 70%-80% site A/C consumption

TP48200B/400B/600B
Integrated Type

*MIMO: Multiple energy input, multiple mode output

Specifications
Integrated power system
Product type
Dimension
(WDH)

TP48200B

TP48400B

TP48600B

600mm600mm2000mm

600mm600mm2000mm

600mm600mm2000mm

Rated capacity

200A

400A

600A

Battery space

16-32U(2-4190Ah)

32U(4190Ah)

24U(3190Ah)

User space

0-16U

N/A

N/A

Input mode

220V single phase


380V three phase
110V dual-wire

220V three phase


380V three phase

220V three phase


380V three phase

LLVD: (MCB)5 branches


BLVD: (MCB)6 branches

LLVD: (MCB)10 branches


BLVD: (MCB)8 branches

LLVD: (fuse)4 branches+(MCB)10


branches
BLVD: (MCB)6 branches

Load branches

Combined power system


Product type
Dimension
(WDH)
Rated capacity

Installation mode

Input mode

Load branches

TP48300B

TP48600B

Mini TP48300B

600mm400mm1600mm

600mm400mm1600mm

442mm360mm480mm

300A

600A

300A

Antistatic floor/ ground installation

Antistatic floor/ ground installation

On the battery rack, 19/21/23 inches


open rack, ground, DFMU cabinet,
wall-mounted

220V single phase


380V three phase

220V three phase


380V three phase

220V single phase


380V three phase
110V dual-wire

LLVD: (fuse)7 branches+ (MCB)3


branches
BLVD: (MCB)4 branches

LLVD: (fuse)5 branches+ (MCB)7


branches
BLVD: (MCB)9 branches

LLVD: (MCB)8 branches


BLVD: (MCB)6 branches

Outdoor Power System


100A-400A/6kW-24kW
Introduction
TP48200A(TP48400A) is an AC/DC outdoor power system
that configures 48V/50A rectifier modules to supply rated of
200A(400A) output current, with various cooling system: heat
exchanger(HEX), direct ventilation(DV) and TEC cooling. The power
system has excellent performance such as wide range of AC input
voltage, high power efficiency, intelligent battery management and
remote monitoring.

Application Scenarios
TP48200A/TP48400A
Integrated Type

Outdoor carriers wireless site power scenarios


Outdoor enterprise communication network power scenarios
WIRE(2U)
POWER
(6U)

R
R
U

R
R
U

WIRE(2U)

TMC

WIRE(2U)

TMC

POWER
(6U)

BBU(2U)

POWER
(6U)

BBU(2U)

BBU(2U)

BBU(2U)

R
R
U

BBU(2U)
BBU(2U)
SPARE

SPARE

SPARE

RFC
BATTERY

Typical outdoor
DBS

BATTERY

Typical outdoor
BTS

RFC
BATTERY

Typical outdoor
DBS+BTS

Features

TP48200A
Separated Type

Cooling capacity up to 1500W, operation temperature can be


-40C-45C, IP55 protect level, protect main equipment to be
safe and reliable
High power efficiency of rectifier >98%, intelligent rectifier
dormancy, saving energy
Support electronic labels, can be co-managed by HUAWEI main
equipment OSS, saving management and maintenance cost
Intelligent battery management and online test, prolonging
battery lifespan
Cooling system equipped in door, easy maintance

TBC300A
Separated Type

Specifications
Integrated cabinet steel series(1.5m Height)
Product Type
System capacity
Dimension
(WDH)
Cooling

TP48200AHD15A6

TP48200AHD15A9

TP48200AHT15A5

TP48200AHT15A6

TP48200AHX15A1

650mm650mm1500mm
HEX(850W)+DV
220V/380V

User space

9U

Heater

TP48200AHD15A8

200A

Input mode
Battery space

TP48200AHD15A7

HEX(850W)+TEC
110V

220V/380V

110V

220V/380V

HEX(850W)
110V

220V/380V
25U

16U(2190Ah)
N/A

N/A
500W

N/A

Heat by TEC

500W

N/A

Integrated cabinet steel series(0.9m Height)


Product Type
System capacity
Dimension
(WDH)
Cooling

TP48120A-HD09A1

HEX(1500W) +DV
220V/380V

User space

8U

Heater

TP48120A-HD09A3

TP48120A-HD09A4

650mm650mm1500mm

Input mode
Battery space

TP48120A-HD09A2

120A

HEX(850W) +DV
110V

220V/380V

110V

8U(1100Ah)
500W(Optional)

Separated power cabinet series


Product Type
System capacity
Dimension
(WDH)
Cooling

TP48200A-HX09A5

TP48200A-HX09A6

TP48200A-HX09A7

200A
650mm650mm900mm
HEX(850W)

Input mode

220V single phase/380V three phase

User space

11U

110V dual-live wire

N/A
15U

Separated battery cabinet series


Product Type
Dimension
(WDH)
Cooling
Battery space
Heater

TBC300A-DCA7

TBC300A-DCA6

TBC300A-TCA3

650mm650mm900mm
DV

DV

TEC

Without heater

Heat by TEC

16U(2190Ah)
With heater (500W)

Wall-mounted Power System


30A-60A/1.74kW-3.2kW
Introduction
TP4860C and TP4860H are 2 types of wall-mounted power system,
which can convert from 220VAC single-phase or 110VAC dual-live
wire input to stabilized -48V DC output. Its largest capacity is 60A.
When configured with inverter, it can output -48VDC and 220VAC
simultaneously . It can be built in 20Ah/40Ah VRLA battery. It
provides great performance such as compact design, high efficiency
and flexible power backup.

Application Scenarios
Wireless coverage sites power supply
WLAN power supply

Remote power supply

TP4860H

Small site power supply

Features
High rectifier efficiency over 96% helps to save energy, output
without derated below 55C
Support built-in inverter to output AC&DC simultaneously
Support flexible installation mode, such as wall mounted, pole
mounted and grounding installation
High protection level of IP55
Low noise and high environment adaptability

TP4860C

Specifications
Wall-mounted power system
Type

TP4860H
Dimension
(WDH)

System

450mm300mm580mm

TP4860C
450mm (excluding 50mm protuberant part
on the vent port)300mm630mm

Rated capacity

DC: 1740W / 2000W / 3200W, AC: 700W (1000VAC)

Cooling mode

Natural cooling

DV

Wall-mounted / floor-mounted

Wall-mounted / pole-mounted / floor-mounted

IP21

IP55

Installation mode
Protection level
AC input
Inverter output (optional)

220VAC single phase or 110VAC dual-live wire


3 branches

AC Distribution
AC SPD
Signal port SPD

20kA/40kA, 8/20s
3kA/5kA, 8/20s

Maximum output

3200W

Battery branch

1 branch

DC Distribution
BLVD
DC SPD
Rectifier

Rated power
Sensors interface
Signal input

3 branches
N/A

10kA / 20kA, 8/20s

870W, 1000W or 1600W (optional)


Battery temperature, door, battery mid-point voltage check
7 Digital input

Controller
Alarm output

4 Dry contact output

Communication port

RS485 / RS232

Rated output

1000VA/700W

Inverter (optional)
Working mode

Default by DC input priority

Rated capacity

20Ah/40Ah VRLA battery or 40Ah lithium battery

Normal voltage

12V

Battery (optional)

Embedded Power System


30A-400A/1.74kW-24kW
Introduction
This series of embedded power products includes 5 types of
products: ETP4830, ETP4890, ETP48150, ETP48200 and ETP48400.
They can provide wide range of DC output from 30A to 400A,
and are very broad application in DC power system scenarios. The
functional unit using a standardized installation structure design,
power height ranging from 1U to 11U, compact design, support
19-inch rack or cabinet installation. The system can be adapted
to a wide range of AC input voltage, with intelligent battery
management, remote monitoring, etc.

ETP4830

ETP4890

Application Scenarios
ETP48150
Access network
Transmission network
Wireless base station
Communication network of enterprise

ETP48200

Newly-built site

Legacy site modernization

Features
High rectifier efficiency over 98% helps to save energy, derated
output above 55C
Rectifier with MTBF > 500,000h helps to save OPEX
E-label function, can achieve assets management of the whole
site, easy for assets management and location of problem quality
Capacity covers 30A - 400A
Smooth expansion of capacity from 200A to 400A and ACDB &
DCDB
Only 5U for 200A system, 12kW/U high power density
Support 19/21 inch standard rack
Standard FE, RS485/232 port , supporting 5 AI, 9 DI, 8 DO
Support MIMO (solar access, 24V output, etc.) evolution

ETP48400

*MIMO: Multiple energy input, multiple mode output

Specifications
Small and medium capacity embedded power system
Type

ETP4830
Dimension
(WDH)

System

Installation mode
Protection level
Input mode

AC Distribution

SPD
Maximum capacity
DC Distribution

Battery breakers
Load breakers
Type
Signal input

Controller

Alarm output
Communication port

442mm255mm43.6mm
(1U)

ETP4890
442mm255mm86.1mm
(2U)

ETP48150
442mm255mm130.5mm
(3U)

Installed on 19-inch rack or cabinet


IP20
220VAC single phase or
110VAC dual-live wire

220/380VAC 3-phase or 220VAC single phase or 110VAC duallive wire

5kA/10kA, 8/20us
2kW

4.8kW

8kW

1 branch

1 branch

1 branch

2 branches

4 branches

8 branches

SMU01A

SMU01B

SMU01C

7 digital input, 2 analog input

2 digital input

8 dry contact output


RS232/485, FE

4 dry contact output


RS232/485

Large capacity embedded power system


Type

System

ETP48200
Dimension
(WDH)

482.6mm330mm222.5mm(5U)

Installation mode

Installed on 19-inch rack or cabinet

Protection level
Input mode
AC Distribution

220/380VAC 3-phase, 220VACsingle phase, or 110VAC dual-live wire

Output breakers

1 branch

2 branches

30kA/60kA, 8/20us

5kA/10kA, 8/20us

12kW

24kW

Battery breakers
Load breakers
SPD
Signal input
Alarm output
Communication port

10

IP20

1 branch

Maximum capacity

Controller

442mm330mm489.5mm(11U)

Input breakers

SPD

DC Distribution

ETP48400

2 branches
Maximum 10 branches

16 branches

10kA/20kA, 8/20us
6 digital input, 1 door magnetism, 1 water logging, 1 smoke, 2 temperature, 1 battery
temperature, 1 environment temperature and humidity
8 dry contact output
RS232/485, FE

Full Series of Monitoring Modules


SMU02B
Introduction
SMU02B is a type of high-end monitoring unit for site and power.
It can monitor and manage telecom power system, and provides
site monitoring function. LCD screen and keyboard are equipped
in the unit to realize man-machine interaction. It has a serial
communication port and an Ethernet port to realize local and
remote monitoring. SMU02B supports the monitoring management
of HUAWEIs power system series, including embedded power,
indoor power and outdoor power system.

SMU02B

Features
Performs comprehensive power management and intelligent
battery management
Grid quality detection
Support time, voltage, capacity disconnecting protection and
LLVD1, LLVD2, BLVD
Supports north CAN and FE ports accessing and support SNMP
protocol through FE interface
Support local display and configuration by LCD screen or HTTPS
browsing
Supports electronic label function
Support remote management and remote software upgrade from
NetEco
Supports downloading historical logs and statistics data
Provides 5 analog inputs(AI), 12 dry contact outputs(DO) and 9
Boolean value inputs(DI)
Provides multiple ports accessing, such as smoke sensor, door
status sensor, water sensor, battery temperature sensor, ambient
temperature and humidity sensor
Supports multiple languages, such as English, Chinese, Turkish,
Spanish, Portuguese and German
Supports hot plug

11

Full Series of Monitoring Modules


ECC500
Introduction
ECC500(Energy Control Center) is a central control unit of
PowerCube system, which adopts advanced power conversion
technology and intelligent management to maximize efficiency
of energy utilization. It consists of main control module, basic I/
O module, expansion I/O module, GPRS module(optional), D.G.
control module(optional) and one reserved slot.

ECC500

Features
Unified controller with comprehensive data acquisition function
Supports multiple energy input and adopts advanced energy
scheduling strategic to matching different hybrid power
application scenario.
Supports comprehensive management of power, energy storage
system, environment and intelligent equipments.
Support remote management and remote software upgrade from
NetEco.
Support local display and configuration by LCD screen or HTTPS
browsing
Support time, voltage, capacity disconnecting protection and
LLVD1, LLVD2, BLVD
Supports electronic label function
Supports downloading historical logs and statistics data
Provides multiple ports accessing, such as smoke sensor, door
status sensor, water sensor, battery temperature sensor, ambient
temperature and humidity sensor
Supports multiple languages, such as English, Chinese, Turkish,
Spanish, Portuguese and German
Supports hot plug
Support extended IO port
Support GPRS communications with NetEco server

12

Full Series of Rectifier Modules


15A-100A/870W-6,000W
Introduction
R4815G

HUAWEI 1U height rectifier module with high efficiency and high


power density can cover the output capacity from 15A to 100A
or from 870W to 6000W. Rectifier efficiency is over 96%, and has
tremendous features such as high reliability, high power density, soft
start, excellent input and output protection, low noise and multimodule paralle.etc. HUAWEI rectifier modules are widely applied in
HUAWEI -48VDC power system such as embedded power, outdoor
power, indoor power and large power system.

R4830G1

R4830G2

Features
Full series of high efficiency modules, applied in multiple
scenarios
Efficiency over 96%, energy saving
1U height, high power density
MTBF over 500,000hours, high reliability
Excellent grid and environment adaptability

R4850G

R4850S

R48100G

Specifications
Module style
R4850S

Dimensions (HWD)
40.8mm105mm281mm

Efficiency

Input voltage

Output power

98%

85-300VAC,
220V single phase or 110V dual live lines

3000W

R4815G1

870W
40.8mm95.5mm208mm

R4830G1
R4830G2

>96%

85-300VAC,
220V single phase or 110V dual live lines

1600W
2000W

40.8mm105mm281mm
R4850G2
R48100G1

3000W
43mm238mm378mm

260-530VAC, three phase three line

6000W

13

Full Series of Advanced Energy Storage Modules


ESM-A2400Wh(D), ESM-A9600Wh(N)
Introduction
HUAWEI advanced Energy Storage Modules(ESM) are a type of
lithium iron phosphate battery integrated with management
system. As an important module of PowerCube diesel hybrid
solution and grid hybrid solution, ESM can be used in off grid
and unstable grid areas. With fast charging adaptability and long
lifespan, ESM can sharply reduce the D.G. running time and O&M
cost comparing with traditional solutions.

ESM-A2400Wh(D)

Features
High charge acceptance to ensure rapid and complete recharge
Long shelf life up to 2 years at 35C due to low self-discharge
Good performance at high temperature up to 55C
Support parallel use and maximum capacity of 28.8kWh in
parallel

ESM-A9600Wh(N)

Specifications
ESM-A2400Wh(D)
Nominal Voltage
Operating Voltage
Charging Voltage@ 25C
Recommended Operating Temperature
Self Discharge @ 25C
Nominal Capacity

47V-58V DC
56.4V
25C-35C
Less than 5% after 90 days storage
2400Wh@ 5hr, 25C

9600Wh @ 5hr, 25C

Approx. 42.5kg

Approx. 125kg

50 A

100 A

ESM-A Dimension(WxDxH)

435mmx420mmx125 mm

440mmx500mmx500mm

ESMU Dimension(WxDxH)

444mmx310mmx44.5mm

Total Weight
Maximum Charging Current Limited

14

ESM-A9600Wh(N)

48V

New Generation Telecom Power Solution


MTS9000A
Introduction
Huawei new generation telecom power solution (MTS9000A) ensures carriers realize network easy deployment, site level
saving, efficient O&M and smooth evolution for its easy, intelligent and high efficiency performance. Huawei MTS system
highly integrates power system, cooling system, site monitor system and housing system to provide safe and reliable
environment for main equipment.
MTS9000A solution could be widely used in outdoor sites.
wireless coverage site
Transmission node site

Solution
Huawei new generation telecom power solution MTS9000A
provides plentiful intelligent management functions to make
telecom power system easy and high efficiency.

MTS9000A
SOH management
MTS9000A provides SOH management based on monitoring
battery cell SOH & SOC (Status of health, status of charge) in real
time, to prolong battery serving life and avoid site power failure.

SOH

SOC

Access control management


MTS9000A Intelligent access control management system makes
the O&M easier and safer. The electrical lock on the cabinet is
designed to be opened by:
authorized card within valid period
mobile APP with authorized username and password
NetEco remotely
Smart capture
To reduce carrier investment loss due to illegal invasion, MTS9000A
provide intelligent photograph capture function against illegal
activities. The camera mounted on the top of inner cabinet will take
a series of pictures automatically while invasion, and the pictures
will be sent to OSS center(NetEco) immediately

15

Site energy efficiency management


Huawei MTS9000A solution provide energy information collecting
sensors on site to measure energy input and output, the data will
upload to NetEco server for SEE analysis. NetEco could show SEE
status on multiple customized views.

Mobile APP management


Mobile APP management is a new innovative OSS auxiliary function
supported by MTS9000A, customer can not only maintain telecom
site in mobile APP through OSS server, but also log on though WIFI
module integrated in MTS9000A while arrived site. With the help
of mobile APP, customer could realize network management at
anywhere and anytime.

Benefits
Easy land acquisition for its compact figure, knockdown type cabinet and Multiple energy input & output
Intelligent O&M, Overall energy system and environment monitoring and convenient mobile app supported
Easy Evolution, All modular design, easy expansion and upgrading
High efficiency, High efficiency rectifier and site & network level efficiency management

16

Accessories
Battery SOC & SOH management

Parameters

Item
Dimension
Installation
Working Voltage
Working Current
Communication

iBox
110mm142mm10mm(LWH)
Cabinet interior side wall
12V 2V
Less than 100mA
Northbound interface: Modbus
Southbound interface: Zigbee

Camera

Parameters

Item
Pixels
Lens
Output Format
Night Vision
Communication
Working Voltage
Working Current
Working temperature

Camera
0.3 Million
6mm infrared
JPEG
Monochrome image, 6m distance
RS485, Modbus,
DC 9-15V
Less than 100mA( night vision, less than 300mA)
-20C to 70C

Intelligent Electronic Door Lock

Parameters

Item
Working Voltage
Working Current
Unlock
Record
IP level

eLock
12V 20%
Less than 60mA
Magnetic card, Live APP, OSS, LUI on site
Unlock time and authorization number
Closed status: IP55

AC Meter

Parameters

Item
Working Voltage
Working Current
Detecting Voltage Range
Detecting Current Range
AC PUE Measurement
Precession

AC Meter
36 to 72 VDC
Less than 100mA
90 to 300VAC
0 to 75A
1%

EFUSE

Parameters

Item
Dimension
Distribution
SPD
Working Voltage
Maximum Current

EFUSE
442mm42mm300mm(WHD)
10 Routes, up to 20A/route (5,10,15,20A configurable)
Differ mode: 10kA, ComVmon mode: 20kA; 8/20s
40 to 60VDC
100A

17

Specifications
Product Model
Base Dimension
(W x D)
Height
Application mode
Cabinet
Cooling mode
Maintenance
Panel material
Battery shelf
Protection level
Power Model

Embedded
Power

Capacity
Input voltage
Input frequency
AC input
AC input SPD
Dimension
Rectifier capacity
Rectifier efficiency

DC distribution

Advanced
Features

Environment

Battery
(optional)

18

Optional Features

Operation
temperature
Storage &
transportation
temperature
Humidity
Specification
Capacity

MTS9510A
(Mini-shelter)

MTS9512A

MTS9513A

815mmx735mm
1.4m, 2.0m, 2.3m
2.0m
2.0m
Equipment cabinet
Battery cabinet
Integrated telecom energy solution
Integrated cabinet
HEX (Only for equipment cabinet and integrated cabinet)
DV/TEC (Only for battery cabinet)
DC/AC Aircon
Front operation & maintenance
Sandwich panel
2/3/4 Layers
IP55 for Aircon and HEX, IP45 for DV
ETP48200-C5B4/ ETP48200-C5B5/
N/A
ETP48200-C5C5
ETP48300-C6A1
C4
C3
N/A
200A
200A
200A
300A
N/A
220/380V
110V dual live
220/380V
220/380V
N/A
45Hz to 66Hz
N/A
MCB:163A/3P
MCB:1100A/2P
N/A
N/A
30kA/60kA (8/20s)
N/A
N/A
5U
6U
N/A
3000W
N/A
>96%
LLVD:
LLVD:
LLVD:
LLVD:
280A/1P, 932A/1P
280A/1P, 932A/1P
280A/1P, 332A/1P 280A/1P, 332A/1P
BLVD:
BLVD:
BLVD:
BLVD:
163A/1P, 332A/1P,
163A/1P, 232A/1P,
163A/1P, 332A/1P,
163A/1P, 332A/1P,
N/A
116A/1P
116A/1P
416A/1P
116A/1P
Battery breaker:
Battery breaker:
Battery breaker:
Battery breaker:
2125A/1P
2125A/1P
2125A/1P
4125A/1P
Battery SOH management
Access control management
Smart capture
N/A
Mobile APP management
Site energy efficiency management (unavailable for ETP48300-C6A1)
(Above features are unavailable for ETP48200-C5B4/B5)
-40C to +50C

-40C to +55C

-40C to +45C

-40C to +70C
5% to 95%
12V/2V
Max. 4x190Ah

12V
Max. 3x190Ah

12V
Max. 2x190Ah

12V
Max. 2x190Ah

12V
Max. 2x190Ah

Hybrid Power-Solar Hybrid


PowerCube S1: Pure Solar Solution
Introduction
Pure solar hybrid solution is currently the most favored choice for green power solutions in many regions for low and medium
load sites.

Scenarios
Mountainous areas and isolated islands where the topography is complicated and transportation is inconvenient
Scenic spots which require environment protection.
High Efficiency PV
Module: 15%

United Controller with


Advanced SolarMax
Technology

High-temperature Tolerant
Solar Cycle Battery

High Precision MPPT:


Upto 99.8%

Benefits
Zero OPEX, Zero CO2 emission
More PV panels saving with advanced SolarMax MPPT(Maximum Power Point Tracking) tech.
Multi-anti-theft design to protect assets

19

Configuration

Solution 1 (Outdoor)

Typical Power Load

Solution 2 (Outdoor)

Solution 3 (Outdoor)

Solution 4 (Indoor)

<0.8kW

< 3kW

MPPT(Maximum Power
Point Tracking) box

ECC500(Energy Control Center) with MPPT(Maximum Power Point Tracking) module

Installation Type

Pole-mounted

Ground-mounted

Capacity of SSU

N/A

Max. 8x50A SSU

Capacity of PV Module

Max. 3,000Wp

Max. 24,000Wp

BLVD

1x32A, 2x10A

2x80A, 2x63A

LLVD

N/A

4x32A, 2x16A, 1x10A

Cooling for Equipment

Natural cooling

HEX

Cooling for Battery

Natural cooling

Natural cooling

ICC100

ICC350

ICC310

ICC200

Remaining Space

N/A

7U

26U

31U

Battery Model and


Capacity

TCB-A (Temperature Cycle Battery): 300/400/500/650/800Ah (Max. 4 groups)


SCB-A (Solar Cycle Battery): 200/300/500/600/800Ah (Max. 4 groups)

Controller

EcoCool / Split DC Aircon

Cabinet

Key Technology

20

SolarMax technology includes features such as high precision MPPT(Maximum Power Point Tracking) of upto 99.8%,
high conversion efficiency of 98.50%, high temperature adaptability and high sensation of light.

Hybrid Power-Solar Hybrid


PowerCube S2: Solar & Diesel Solution
Introduction
Solar & D.G. hybrid solution is applicable for modernization of legacy diesel powered sites with medium and high
load in outlying areas.

Scenarios
Areas where sunshine duration fluctuates greatly in each month
Modernization of legacy D.G. powered sites with limited footprint
Systems requiring high reliability requirements
High Pillar Structure &
Anti-theft Bolts

United Controller with


Advanced SolarMax
Technology

IDG: Integrated Diesel Generator

High Efficiency
Rectifier: Upto 96%

Benefits
High reliability
Maximum usage of solar energy with leading algorithm design
Excellent TCO performance with optimized PV & IDG combination

21

Configuration

Solution 1 (Outdoor)

Typical Power Load


Controller
Installation Type
Distribution Capacity
Capacity of PV Module

<3.5kW
ECC500(Energy Control Center)
Ground-mounted
Max. 8x50A (SSU+PSU)
Max. 24,000Wp

BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

Integrated Diesel
Generator Capacity
Cooling for Equipment

Solution 2(Indoor)

10/14kW with 3W+N; 11.5/16kW with dual-live wire or reuse

HEX
EcoCool / Split DC aircon

Cooling for Battery


Cabinet

ICC350

ICC310

ICC200

Remaining Space

7U

26U

31U

Battery Model and


Capacity

TCB-A (Temperature Cycle Battery): 300/400/500/650/800Ah (Max. 4 groups)


DCB-A (Deep Cycle Battery): 300/420/490/600/800Ah (Max. 4 groups)
DCB-B (Deep Cycle Battery): 200/300/500/650/800Ah (Max. 4 groups)

Key Technology

22

Natural cooling

SolarMax technology includes features such as high precision MPPT(Maximum Power Point Tracking) of upto 99.8%,
high conversion efficiency of 98.50%, high temperature adaptability & high sensation of light.

Hybrid Power-Solar Hybrid


PowerCube S3: Solar & Grid (Diesel)
Introduction
Solar & Grid hybrid solution is applicable for medium and high load sites with grid connection.

Scenarios
Areas having unstable grid, Solar energy acts a complement to the unstable grid
Scenarios where Mains supply needs to blend with sustainable energy solution to cut down emission

United Controller with Advanced


SolarMax Technology

Carrier Class Reliability,


Complete SPD Design

Benefits
High reliability
Solar energy is priority
Low TCO, less maintenance costs

23

Configuration

Solution 1 (Outdoor)

Typical Power Load


Controller
Distribution Capacity
Capacity of PV Module

<3.5kW
ECC500(Energy Control Center)
Max. 8x50A (SSU+PSU)
Max. 12,000Wp

BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

AC Input
Integrated Diesel
Generator Capacity
Cooling for Equipment

Solution 2 (Indoor)

220VAC (85-300VAC) , 50/60Hz (45-66Hz) , 3-phase & 4-wire

10/14kW with 3W+N; 11.5/16kW with dual-live wire

HEX
EcoCool / Split DC Aircon

Cooling for Battery


Cabinet

ICC310

ICC200

Remaining Space

26U

31U

Battery Model and


Capacity

TCB-A (Temperature Cycle Battery): 300/400/500/650/800Ah (Max. 4 groups)


DCB-A (Deep Cycle Battery): 300/420/490/600/800Ah (Max. 4 groups)
DCB-B (Deep Cycle Battery): 200/300/500/650/800Ah (Max. 4 groups)

Key Technology

24

Natural cooling

SolarMax technology includes features such as high precision MPPT(Maximum Power Point Tracking) of upto 99.8%,
high conversion efficiency of 98.50%, high temperature adaptability & high sensation of light.

Hybrid Power-Diesel Hybrid


PowerCube D1-Standard & D1-Advanced
Introduction
Diesel hybrid solution is suitable for medium and high load sites with high reliability requirement.

Scenarios
Modernization of legacy D.G. powered sites with low load rate
Areas where Diesel-powered site OPEX is comparatively less than that of the Solar site
Areas lacking professional D.G. maintenance engineers
Integrated Diesel Generator
United Controller with
Advanced DieselMax
Technology

Fuel Level Sensor

5 Levels of Anti-theft
Structure Design

Deep Cycle Battery

Benefits
Up to 75% fuel saving and 90% D.G. running time saving
Up to 97.5% D.G. maintenance cost saving
Smooth evolution to Solar Hybrid Solution

25

Configuration

D1-Standard
(Outdoor)

Typical Power Load


Controller

System Capacity

D1-Standard
(Indoor)

D1-Advanced
(Outdoor)

D1-Advanced
(Indoor)

<5kW
ECC500(Energy Control Center)
Max. 6x50A PSU(Standard)
Max. 8x50A PSU(Co-site)

Max. 8x50A PSU

Max. 6x50A PSU

Max. 8x50A PSU

Integrated Diesel
Generator Capacity

10/14kW with 3W+N; 11.5/16kW with dual-live wire(standard/advanced), 10/14kW with 3W+N;(Co-site)

Integrated Fuel Tank


Capacity

800L

BLVD

2x80A, 2x63A(standard/advanced), 1x63A/tenant, total for 4 tenants(Co-site)

LLVD

4x32A, 2x16A, 1x10A(standard/advanced), 1x63A,2x80A/tenant, total for 4 tenants(Co-site)

AC Input
Cooling for Equipment

220VAC (85-300VAC), 50/60Hz (45-66Hz), 3-phase & 4-wire


HEX

HEX
EcoCool / Split DC Aircon

Cooling for Battery

EcoCool / Split DC Aircon


DC Aircon / Free cooling

Cabinet

ICC500

ICC 900

ICC200

ICC500

Remaining Space

12-14U

19-29U

31U

14U

Battery Model and


Capacity

TCB-A (Temperature Cycle Battery):


300/400/500/650/800Ah (Max. 2 groups)
DCB-A (Deep Cycle Battery):
300/420/490/600Ah (Max. 2 groups)
DCB-B (Deep Cycle Battery):
200/300/500/650Ah (Max. 2 groups)

Key Technology

26

DC Aircon / Free cooling

ICC900

ICC200
31U

For ICC500,
ESU-A (Advanced Energy Storage Unit),
Max. 2x200Ah
For ICC900,
ESU-A (Advanced Energy Storage Unit),
Max. 3x200Ah + 2x150Ah backup batteries(optional)

DieselMax Technology includes features such as dynamic load algorithm, high AC to DC conversion efficiency of 96%
and high charging/discharging efficiency of 96%

Hybrid Power-Grid Hybrid


PowerCube G2: Advanced Fast Charging Solution
Introduction
Advanced fast charging system is feasible when electricity grid is unreliable and outage time is short but frequent.

Scenarios
Modernization of Grid plus backup D.G. powered sites
Areas lacking professional D.G. maintenance engineers

United Controller with


Advanced GridMax Technology

Advanced Energy Storage Unit

Benefits
Fast charging: Full charging < 2hrs
Energy storage: 4-5 years lifespan
Zero D.G. running time or removing D.G.
Smooth evolution to Solar Hybrid Solution

27

Configuration

G2 (Outdoor)
Typical Power Load

G2 (Indoor)

<5kW

Controller

ECC500(Energy Control Center)

AC Input

220VAC (85-300VAC) , 50/60Hz (45-66Hz) , 3-phase & 4-wire

System Capacity
Cooling for Equipment

Max. 6x50A PSU

Max. 8x50A PSU

HEX
EcoCool / Split DC Aircon

Cooling for Battery


BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

Cabinet

ICC500

ICC900

ICC200

Remaining Space

14U

14U

31U

Battery Model and


Capacity

ESU-A (Advanced Storage


Energy Unit):
200Ah (Max. 2 groups)

ESU-A (Advanced Storage


Energy Unit):
200Ah (Max. 3 groups)

ESU-A (Advanced Storage Energy Unit):


200Ah (Max. 4 groups)

Key Technology

28

DC Aircon

GridMax Technology includes features such as fast charging, step charging and high adaptability

Hybrid Power-Grid Hybrid


PowerCube G3: Enhanced Fast Charging Solution
Introduction
Enhanced fast charging system is used for areas where electricity grid not only faces often short outages but also
seldom abnormal long outages.

Scenarios
Modernization of Grid plus backup D.G. powered sites
Areas lacking professional D.G. maintenance engineers

United Controller with Advanced


GridMax technology, Unique Control
Algorithm of Hybrid Energy Storage

Hybrid Energy Storage

Benefits
Fast charging: Full charging < 3hrs
Energy storage: 4-5 years lifespan
Zero D.G. running time or removing D.G.
Smooth evolution to Solar Hybrid Solution

29

Configuration

G3 (Outdoor)
Typical Power Load
Controller
System Capacity
AC Input
Cooling for Equipment

G3 (Indoor)

<5kW
ECC500(Energy Control Center)
Max. 6x50A PSU

Max. 8x50A PSU

220VAC (85-300VAC) , 50/60Hz (45-66Hz) , 3-phase & 4-wire


HEX
EcoCool / Split DC Aircon

Cooling for Battery


BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

Cabinet
Remaining Space

Battery Model and


Capacity

Key Technology

30

DC Aircon

ICC500

ICC900

ICC200

14U

9U

28U

ESU-A (Advanced Storage Energy Unit): 50Ah.


FCB-A (Fast Charging Battery): 200/300/400/500/650Ah
Max. 2x50Ah ESU-A +
1x400Ah FCB-A

Max. 3x50Ah ESU-A +


1x650Ah FCB-A

GridMax Technology includes features such as fast charging,


step charging and high adaptability.

Max. 3x50Ah ESU-A + 1x650Ah FCB-A

Hybrid Power-Grid Hybrid


PowerCube G4: Standard Fast Charging Solution
Introduction
Standard fast charging system is suitable for areas where electricity grid has seldom daily outages.

Scenarios
Modernization of Grid plus backup batteries powered sites
New-building sites in unstable grid areas

Split DC Aircon

United Controller
with Advanced
GridMax Technology

Fast Charging Battery

Benefits
Fast charging: Full charging < 4hrs
Energy storage: 3-4 years lifespan
Zero D.G. running time or removing D.G.
Smooth evolution to Solar Hybrid Solution

31

Configuration

G4 (Outdoor)
Typical Power Load
Controller
System Capacity
AC Input
Cooling for Equipment

G4 (Indoor)

<5kW
ECC500(Energy Control Center)
Max. 6x50A PSU

Max. 8x50A PSU

220VAC (85-300VAC) , 50/60Hz (45-66Hz) , 3-phase & 4-wire


HEX
EcoCool / Split DC Aircon

Cooling for Battery


BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

Cabinet
Remaining Space

Battery Model and


Capacity

Key Technology

32

DC Aircon / Free cooling

ICC500

ICC900

ICC200

12U

27U

31U

FCB-A (Fast Charging Battery): 200/300/400/500/650Ah


Max. 1x650Ah FCB-A

Max. 2x650Ah FCB-A

Max. 1x650Ah FCB-A

GridMax Technology includes features such as fast charging, step charging and high adaptability.

Hybrid Power-Grid Hybrid


PowerCube G4 Mini: Mini Standard Fast Charging Solution
Introduction
Mini-Standard fast charging system is suitable for areas where the electricity grid suffers from weekly multiple
longtime outages.

Scenarios
Modernization of Grid plus backup batteries powered sites
New-building sites in unstable grid areas

United Controller with Advanced


GridMax technology

Fast Charging
Battery (12V per cell)

Benefits
Fast charging: Full charging < 4hrs
Energy storage: 2-3 years lifespan
Zero D.G. running time or removing D.G.
Smooth evolution to Solar Hybrid Solution

33

Configuration

G4 Mini (Outdoor)
Typical Power Load
Controller
System Capacity
AC Input
Cooling for Equipment

G4 Mini (Indoor)

<3kW
ECC500(Energy Control Center)
Max. 6x50A PSU

Max. 8x50A PSU

220VAC (85-300VAC), 50/60Hz (45-66Hz), 3-phase & 4-wire


HEX
EcoCool / Split DC Aircon

Cooling for Battery


BLVD

2x80A, 2x63A

LLVD

4x32A, 2x16A, 1x10A

Cabinet

ICC330

ICC200

Remaining Space

8U

31U

Battery Model and


Capacity

FCB-B (Fast Charging Battery): Max. 2x150Ah

FCB-B (Fast Charging Battery): Max. 4x150Ah

Key Technology

34

Free Cooling

GridMax Technology includes features such as fast charging, step charging and high adaptability

Intelligent Video Surveillance Power Solution


PowerCube500: IVS Solution
Introduction
Intelligent video surveillance demands grow rapidly. HUAWEI IVS solution can be applied in various scenarios from good
grid, poor grid to off grid.
National security infrastructure demands in terms of border monitoring, fortress spot protecting and website facility
management will adopt the IVS system, which sites grid are unavailable.
As energy saving and environment friendly demands, in densely populated areas will adopt the IVS system, especially
in city, road, square, scenic spot etc.

Scenarios
Modernization of Grid plus backup batteries powered sites
New-building sites in unstable grid areas

Solar Panel
Camera

Camera

Integrated cabinet,
including battery,

Integrated cabinet,

power converter, etc.

including battery,
power converter, etc.

Grid hybrid IVS solution

Solar hybrid IVS solution

Benefits
Higher efficiency, energy saving, green & environment friendly
Simplified configuration
Easy deployment and footprint saving, pole-mounted or ground installation supported
Anti-theft design and assets protected

35

Configuration

Typical Power Load

Solution 2

Solution 3

Solution 4

None Backup Time

Short Backup Time

Long Backup Time

Off Grid

<300 W

<150 W

<150 W

<80 W

Grid

Grid + Battery

Grid + Battery

Solar + Battery

Autonomy Time

0 Hours

2 Hours

12 Hours

72 Hours

Installation Mode
(Cabinet)

Pole Mounted

Pole Mounted

Pole Mounted
/Ground Installation

Pole Mounted
/Ground Installation

Power Supply Source

Height of Pole
Maximum PV Capacity
Input AC Voltage

SPD

36

Solution 1

Typical 6m
N/A

800Wp

110/220 V

N/A

AC port: 5kA/10kA,
FE port: nominal 2kA/6kV

Output Voltage

DC12V
Optional (DC48V PoE, AC 24V, AC 220V)

Protection Level

IP55

Site Energy Management Specialist


iManager NetEco (Site)
Introduction
Network Availability = Communication Availability * Transmission Availability * Energy Availability
Site will be out-of-service during energy interruption. Well managed perfect communication equipment and well
managed perfect transmission equipment together with perfect energy system are not necessarily bring high network
availability and satisfied revenue, unless energy system is simultaneously well managed.
Conventional inefficient manpower-based O&M mode can not meet in depth needs of increasing network scale and
diversified types of energy supply and consumption.
Facing cutthroat competition, we never must be considered as they are now of meticulous management for electricity,
fuel, efficiency and asset, to improve profitability by cutting OPEX.

Scenarios
NetEco is innovated to adapt to these strategies, it is a centralized remote OSS solution for site energy equipment. The
following diagram indicates the unique features and customer values of NetEco solution.
Flexible Server Options:
Small-scale
(<=1000 Sites)

Medium-scale
(<=2000 Sites)

Large-scale
(<=5000 Sites)

NetEco

Mobile APP
Northbound

3rd Party System

Networking

Transmission-Saving
In-band networking solution

In-band
Green Channel

Flexible and Stable

OR

Out-of-band
GPRS/IP/E1

Out-of-band networking solution

Adaptable to
diversified
scenarios

Hybrid Power Systems


Grid Hybrid
Diesel Hybrid Solar Hybrid

Site Power Systems


Indoor Power

Outdoor Power

Embedded
Power

Saving Site data


acquisition
devices-free

Benefits
Better back high efficient O&M, makes O&M visible, controllable and manageable; realize automation and information,
reduce manpower site visit; assists preventative maintenance, provides prediction and expert suggestion.
Improves power availability, ensures smooth communication, improves QoS and QoE; drives revenue and subscribers
increasing.
Makes site energy saving manageable, controllable and measureable; supports PUE analysis and optimization.

37

Configuration
Items

Specifications and/or Features


Small scale

Medium scale

Large scale

1,000 sites per server

2,000 sites per server

5,000 sites per server

System Capacity

In-band transmission

Out-of-band transmission

For some Huawei 3900 G/U/L serials macro sites

IP, GPRS, E1, etc.

Networking mode

Integration with
3rd party

Alarm SNMP northbound interface: supports SNMP v1, SNMP v2c, and SNMP v3;
Performance SNMP northbound interface, based on SNMPv3

Platform function

Supports management of multiple time zones, data backup and restore, online help

Real-time monitoring

GIS site Map (based on Google Map), real-time monitoring, GUI, power supply logics, customized real-time counter
subscription and my workspace

Alarm management

Alarm collection and storage, alarm browse, alarm notification, alarm processing, alarm setting, dry contact alarm
management, alarm masking and alarm thresholds setting

Configuration Mgmt.

Site controller discovery, graphical drag and drop site configuration, batch sites copy and batch parameters modification,
site parameter setting by SMS; configuration data export to EXCEL

Performance and
Report
Security management
Asset management
Value-added features

Historical data collection, query, statistical analysis, report management; customized report, automatic periodic report
Network security management, role and operation authority management, user and password management, operation
authentication, log management, ECC500-based video capture
Inventory data management, asset anti-theft
Overall network battery management, overall network diesel generator and fuel management, site DC power sharing,
Diesel Max II efficiency optimization

Preventative
maintenance

Early-warning: reduces the probability of power failure


Maintenance reminder: D.G. refueling, defected battery changing, etc.

Prospective Prediction

Operating time prediction: D.G. fuel capacity, battery backup time, etc.
Lifespan prediction: Battery remain capacity, discharge times, etc.

Remarks: Features are constrained to the configuration of site hardware and controller software, as well as NetEco versions.

38

Migrate Towards Simplicity

Global Recognition, Market Share No.1


24.7% Market Share of Global Telecom Power in 2013, NO.1 in Industry.
1,600,000+ power system, 170+ countries, 310+ operators
130+ service branches, 1,100+ professional partners, 724 hours service
DC Power

98% Efficiency Rectifier

Global Product Leadership

Recommended Excellent

Award for DC Power Market

Solution Award

Frost & Sullivan

CIC

Data Resource: Frost & Sullivan

Copyright Huawei Technologies Co., Ltd. 2015. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademark Notice
, HUAWEI, and

are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, product, service and company names mentioned are the property of their respective owners.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information

HUAWEI TECHNOLOGIES CO., LTD.


Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-022333-20141109-C-1.0

is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.

www.huawei.com

You might also like