Electrical Rating

Input Supply

- 100-265VAC

Power Consumption
Relay Rating

- <4 W
- 30A(Resistive) at 230VAC (Upto 1.5HP
Single Phase)

Maximum Cable Length(Sensor) - 60Meter (4 Core Multi stranded


Cable )

Parameter Setup
1.Press and Hold Enter/Fill Button at Boot Time
2.Press Enter/Fill Button for Parameter Navigation
3.Chaging the Parameter by Pressing Select/Change Button
4.Press Enter/Fill Button for Digit Navigation
5. Press Select/Change Button Increment value
6.For Next Window Navigate Cursor to >> and Press Select/Change Button
7. For Saving Navigate Cursor to >> and Press Select/Change Button
8.Press Select/Change Button again Press Select/Change Button

Time and Date Setup


1.Press and Hold Select/Change Button at Boot Time
2.Select Each Parameter by Pressing Enter/Fill Button
3.Change Value By Pressing Select/Change Button

Symbols
R: - Reserve Level in Percentage
E: - Tank Height from Sensor in CM
ETFP:- Time Out Cutoff Enable or Disable
F:- Time Out Lockout Counter
Time Slots :- Check the water level on that time(For Corporation water consumers)
T: - Total Time to to Fill the Tank
Eg: Tank Height = 130cm,Reserve Level=67%,Corporation water Timing Morning 7 O
clock and evening 6:30
1. Press and Hold Enter/Fill Button at Boot Time
2.Press Enter/Fill Button and Navigate to R: Position on the window
3.Press Select/Change Button
4.Press Select/Change Button to Increment the Digit to 6
5.Press Enter/Fill Button to Select Next Digit
6.Press Select/Change Button to Increment the Digit to 7
7.Press Enter/Fill Button and Navigate to E:
8. Press Select/Change Button
9. Press Select/Change Button to Increment the Digit to 1
10. Press Enter/Fill Button to Select Next Digit
11. Press Select/Change Button to Increment the Digit to 3
12. Press Enter/Fill Button to Select Next Digit
13. Press Select/Change Button to Increment the Digit to 0
14. Press Enter/Fill Button and Navigate to ETFP:
15.Press Select/Change Button to Enable or Disable Select D to Disable
16. Press Enter/Fill Button and Navigate to >> for getting Next window

17. Press Select/Change Button for Time Slot Setup


18. Press Select/Change Button to Increment the Digit to 0
19. Press Enter/Fill Button to Select Next Digit
20. Press Select/Change Button to Increment the Digit to 7
21. Press Enter/Fill Button to Select Next Digit
22. Press Select/Change Button to Increment the Digit to 0
23. Press Enter/Fill Button to Select Next Digit
24. Press Select/Change Button to Increment the Digit to 0
25. Press Enter/Fill Button to Select AMPM
26. Press Select/Change Button to Select AM
27. 25. Press Enter/Fill Button to Time slot 2
28. Press Select/Change Button to Increment the Digit to 0
29. Press Enter/Fill Button to Select Next Digit
30. Press Select/Change Button to Increment the Digit to 6
31. Press Enter/Fill Button to Select Next Digit
32. Press Select/Change Button to Increment the Digit to 3
33. Press Enter/Fill Button to Select Next Digit
34. Press Select/Change Button to Increment the Digit to 0
35. Press Enter/Fill Button to Select AM/PM
36. Press Select/Change Button to Select PM
37. Press Enter/Fill Button and Navigate to >>
38. Press Select/Change Button
39. Press Enter/Fill Button
40.Press Enter/Fill Button to Save

Sensor

Overflow
Pipe

30CM
Water

Water:100%

Tank Height

Water:0%

Electrical Connection
Power Supply

Dolphino Aqua

Sensor Connection
1.Extended the Wire along with the Sensor and Connect to the controller

Red

Yellow

Phase

Black

Neutral