You are on page 1of 4

BUILDING PARAMETRS

ARCHITECTURAL AND FUNCTIONAL REQUIREMENTS


Types of building :
Types of structural system:
Number of stories
Design provision for future extension
Story Height
Height of parapet wall
Total height of the Building
Least lateral base dimension of the building
External wall/ some internal wall
Few internal wall
Plaster thickness

Residential Building
Reinforced Concrete Frame
3+staircover
0 storey
2.5m
1m
9m
5m
230 mm
115 mm
15 mm

DIMENSIONS AND MATERIALS


Slab thickness
Footing
Tie Beam size (mm)
Beam size (mm)
Column size (mm)

125mm
230 x 300
230 x350
350 x 350

CONSTRUCTION MATERIALS
Cement
Grade of concrete
Grade of steel

Ordinary Portland cement


M20
Fe415, Fe500

ASSESSMENT OF UNIT LOADS OF MATERIALS


DENSITY OF MATERIALS
Reinforced concrete
Brick masonry
Rebar

25.0KN/m3
19.2KN/m3
78.5KN/m3

ASSESSMENT OF LIVE LOAD


Unit loads on floor
All Rooms and kitchen
Toilet and Bathrooms
Corridors , passage, staircases, Verandas
Roof (accessible)
Roof (Non accessible)

2.0 KN/m2
2.0 KN/m2
3.0 KN/m2
1.5 KN/m2
0.75 KN/m2

SEISMIC LOAD CALCULATION:

NBC 105, Seismic load Evaluations


Design Horizontal Seismic Coefficient,Cd
Seismic Zone factor, Z

CZIK

Importance factor, I
Structural performance factor, K
height of the building
Dimension of the building Along X, Dx
Dimension of the building Along Y,DY
Time period of the building along X, Tx=0.09h/Dx
Time period of the building along Y,Ty=0.09h/Dy
Soil type
Basic Seismic Coefficient Along X, C (for 500YRP
Earthquake)
Basic Seismic Coefficient Along Y, C (for 500YRP
Earthquake)
Design Horizontal Seismic Coefficient, Cd
Seismic Weight of the Building For DL+0.5LL
Combination
Base Shear

Beam Reinforcement bars


For Floor beams:

Top Bar @ 3-12 +2-16mm dia Fe 415


Bottom Bar @ 2-16 + 1-12 mm dia Fe 415
For Plinth Tie-beams:

Top Bar @ 3-16 +2-16mm dia Fe 415


Bottom Bar @ 3-16 mm dia Fe 415
Strriups at beam 8mm

1 Cl:8.1.6, fig 8.2


Cl:8.1.7, Table
1.5 8.1
1
3.2 m
20.401 m
7.267 m
0.06 Sec
0.11 Sec
ii
For Medium soil
0.09
0.09
0.135
1914.0
2 KN
258.39 KN

PUSHOVER ANALYSIS OUTPUT OF EXISTING BUILDING

For 500 YRP Earthquake


Performance Point
(V,D) = 768.179kN, 30.231mm

For 1000 YRP Earthquake


Performance Point
(V,D) = 825.678kN, 43.765mm
(Sa, Sd) = 0.258g, 26.458mm

Conclusion:
A Pushover analysis was performed to assess the performance level of the building at different level of
earthquake demands. As per the results, it can be asserted that the buildings performance is good in both
direction as it reached Immediate Occupancy level when subjected to the respective earthquake demand.
Other than that the level of performance is safe to withstand earthquakes.