You are on page 1of 1

ADJUSTABLE RING

PIPE HANGER FOR SIZE 65mm.(2 1/2") LARGER

PIPE HANGER FOR SIZE UP TO 50mm.(2")

PIPE THRU FLOOR AND PIPE THRU WALL

A
STEEL ROD

STEEL ROD
ESCUTCHEON PLATE
( FOR EXPOSED PIPE )

STEEL HANGER

STEEL HANGER

EXPANSION BOLT

CL OF PIPE

WELD

CONCRETE SLAB
CONCRETE SLAB
C-CHANNEL

mm.

INCH

ROD
TAKE - OUT
E

ADJUSTMENT
F

STRAP
SIZE
(mm.xmm.)

1/2"

15

46

59

64

29

25

2 x 25

3/4"

20

52

67

64

33

25

2 x 25

1"

25

56

73

64

37

25

2 x 25

1 1/4"

32

65

87

64

46

32

2 x 25

1 1/2"

40

70

94

64

49

32

3 x 25

2"

50

75

106

64

56

32

3 x 25

NOTE :

MEANS PIPE DIAMETER AND/OR PIPE DIAMETER PLUS INSTALLATION.(IF ANY)

VENT THRU ROOF DETAIL

WALL PLATE
( FOR EXPOSED PIPE )

PIPE

NUT & WASHER


(NON-CORROSIVE)

DIMENSION. (mm.)
A

1/4" THK. ANCHOR STEEL PLATE


OAKUM
SILICONE CAULKING

OAKUM

RISER CLAMP
PIPE

NOMINAL PIPE SIZE

INTERIOR FIN WALL

SILICONE CAULKING

EXPANSION BOLT

C-CHANNEL

NUT-WASHER
(NON-CORROSIVE)

1/4" THK.
ANCHOR STEEL

STEEL ROD

PIPE SLEEVE

PIPE
STEEL ROD.
NUT & WASHER
(NON-CORROSIVE)

CEILING PLATE
( FOR EXPOSED PIPE )

NUT-WASHER
(NON-CORROSIVE)

SETTING TUBE
STEEL HANGER

WATERTIGHT SLEEVE
BUILDING WALL

WELD

RISER PIPE LEADER

STEEL HANGER

THRU WALL

THRU FLOOR
NOTE :
ALL STEEL PARTS SHALL BE PAINTED WITH 2 COATS
OF ANTI-RUST PAINT AND 1 COAT OF FINISHED PAINT
OR AS SPECIFIED.

NOTE :
ALL STEEL PARTS BE PAINTED WITH 2 COATS OF ANTI-RUST PAINT
AND 1 COAT OF FINISHED PAINT OR AS SPECIFIED

PIPE

PIPE

CLAMPS FOR VERTICAL PIPE RISER

CONCRETE JOINTS & CONCRETE INSERT

FLEXIBLE CONNECTOR
TWINFLEX
CONTROL UNIT (IT REQUIRED)

C-CHANNEL TABLE 4
EXPANSION BOLT OR INSERT
1/4 THK. STEEL PLATE FABRICATED
FLANGE W/INSECT-SCREEN SANDWICH
BETWEEN FLANGE

STEEL-STRAP CLAMP TABLE 3

HANGER ROAD
EXPANSION SHELD

@ PUMP

CONCRETE JOINTS

SILCONE SEALANT

Clamp

OAKUM

CONCRETE SLAB

A
B

0.50

ABOVE GROUND
50mm LATERAL MOVEMENT

FLEXIDRAIN
50mm LATERAL MOVEMENT

VENT TERMINAL STEEL PIPE

0.20

WATERTIGHT SLEEVE

FLEXIDRAIN (FLANGE TYPE)


50mm LATERAL MOVEMENT

ANCHOR STEEL PLATE


1/4" THK.x0.10 M. WIDE

VENT STACK PIPE PVC.

INSERT NUT

HEAVY DUTY CONCRETE


STEEL INSERT WITH
ELONGATED SLOT

HANGR ROAD

PIPE CHASE

FLOOR SLAB

WALL

CONCRETE INSERT

TYPICAL TRENCH FOR HDPE/PVC. PIPE

UNDER GROUND
50mm LATERAL MOVEMENT

@ UNDER GROUND
(NO PRESSURE)

DETAIL UNDER GROUND SUPPORT

@ ABOVE & UNDER GROUND


(PRESSURE)

TRAPEZE HANGER

HOLLOW CORE SLAB PIPE HANGER

TOPPING SA REQD
PLATE AS REQD

NATIVE SOIL
COMPACTED BACKFILL

EXPANSION BOLT

CONCRETE SLAB

CLIENT

CAST IRON PIPES SIZE 50 TO 150mm.

STEEL CHANNEL

GL.

VARIES TO SLOPE

0.300

0.70(MIN.)

NUT & WASHER


(NON-CORROSIVE)

COMPACTED SAND
0.10

GROUND FLOOR SLAB.

0.60

CONDUIT LT PIPE
HEAVY DUTY

GASKET REQD IF VOID USED


AS AIR DUCT (TYP.)
HANGER ROD TABLE 1

TOGGLE BOLTS MAY BE USED


WHEN THEY DO NOT INTERFERE
WITH SERVICE GORES

STRAPS LOCATED BEFORE GROUTING


STRAP OR ROD

U-BOLT CLAMP TABLE 2

FLAT BAR STAINLESS


STEEL SIZE 25x2.0mm. THK.
SUSPENDED PIPE HANGER

C-CHANNEL TABLE 2

NOTE :
USING FIRED CONCRETE STUDS FOR HANGERS IS ALSO AN EFFECTIVE AND LOW
COST METHOD OF SUSPENDING MECHANICAL AND ELECTRICAL MATERIALS.

ADJUSTABLE CLEVIS HANGER

TABLE FOR PIPE SUPPORT


TABLE 1 ADJUSTABLE CLEVIS HANGER & ROD SIZE
NOMINAL PIPE SIZE

(In)

mm.

STEEL
OR
CHANNEL
mm.

ANGLE

44

1/2

15

50x50x4

114

50

3/4

20

50x50x4

89

130

44

12

25

257

100

142

47

12

1.1/4

320

108

178

54

15

1.1/2

SIZE OF STEEL
B

MENT

INCH

mm.

UPPER

2.1/2

65

5x32

5x32

12

119

155

76

97

44

80

5x32

5x32

12

120

167

76

98

100

6x32

5x32

15

135

198

89

125

6x32

5x32

15

157

228

150

6x38

5x38

19

176

200

6x44

5x44

22

212

LOWER

NOMINAL
G

PIPE SIZE

BOLT & STRAP SIZE


BOLT
mm.

STRAP
mm.

TABLE 3 STEEL STRAP CLAMPS

STEEL

EXPANSION BOLT

PLATE
mm.

SIZE

U-BOLT

QTY.

SIZE
mm.

TABLE 4 C-CHANNEL

PIPE
SIZE

HOLE
SIZE

STRAP
SIZE

SUPPORTS
LENGTH

SUPPORT SIZE

(In)

mm.

15

75

50

3x40

UP TO 2 FT.

100x50x5

25x2

150x150x4

1/4

20

80

55

3x40

> 2 FT. TO 3 FT.

150x80x10

25x2

150x150x4

1/4

25

80

65

3x40

50x50x4

25x2

150x150x4

1/4

32

95

70

3x40

32

50x50x4

25x2

150x150x4

1/4

40

100

80

3x40

40

50x50x4

25x3

150x150x4

1/4

50

145

105

10

3x40

DATE
26-09-13
15-11-13
22-09-14
27-05-15
30-10-15
14-03-16

REVISION DETAILS
ISSUED FOR COORDINATION
ISSUED FOR TENDER
RE-ISSUED FOR TENDER
ISSUED FOR CONSTRUCTION
RE-ISSUED FOR CONSTRUCTION
ISSUED FOR FINAL

SCALE

SIZE

N.T.S.

A1

APPROVED

GN

DATE

DESIGNED

10

250

9x44

6x44

22

230

387

114

212

57

19

CHANNEL

65

160

115

10

5x40

VC

12

300

9x50

6x50

22

290

457

120

258

76

19

50

75x40x5

25x3

200x200x6

3/8

80

160

130

10

5x40

CHECKED

14

350

12x60

6x50

25

316

494

133

275

75

22

2.1/2

65

75x40x5

32x5

200x200x6

3/8

185

145

10

5x40

16

400

12x63

6x63

25

357

584

152

316

76

25

80

75x40x5

32x5

200x200x6

3/8

100

200

160

10

5x40

TP

18

450

12x63

6x63

28

394

629

165

354

95

29

100

75x40x5

12

32x5

200x200x6

3/8

125

225

185

10

5x40

PROJECT

20

500

15x75

9x75

32

438

695

178

367

101

32

125

100x50x5

12

32x5

250x250x8

3/8

150

250

210

10

5x40

24

600

15x75

9x75

32

498

803

191

444

108

32

150

100x50x5

15

38x5

250x250x8

3/8

26

650

15x75

9x75

32

549

890

196

495

116

32

200

150x75x6.5

15

44x5

250x250x8

3/8

30

750

15x75

9x75

32

613

994

210

556

127

32

BSJ
JAKARTA
(SITE B)

DG

LOWER TABLE 1

APPROVED
DG
DG
DG
DG
DG
DG

FOR CONSTRUCTION

DRAWN

NOTES :
1.PIPE SLEEVE SHALL BE GALVANIZED STEEL PIPE CLASS "B"
2.ANCHOR STEEL PLATE OF SLEEVE SHALL BE 0.10 M.
LARGER THAN O.D. OF SLEEVE
3.SLEEVE SHALL BE TWO SIZE LARGER THAN PIPE PASSING
THROUGH

UPPER TABLE 1

TABLE 2 PIPE SUPPORT TO FLOOR AND TRENCH


ADJUST

HANGER ROD TABLE 1

LENGTH

REV
A
B
C
0
1
4

CL OF PIPE

NOTES :
1.MEANS PIPES DIAMETER AND/OR PIPES DIAMETER PLUS INSULATION (IF ANY)
2.ALL PIPE SUPPORT FOR THE UNDER GROUND PIPE SHALL BE COATED WITH 2 NO. EPOXY PAINT. ( 2 NO. PRIMER )
3.DW. PIPE SHALL BE SUPPORT AT A SPACING NOT EXCEEDING 1.2 m.
4.STEEL PIPE SHALL BE SUPPORT AT A SPACING NOT EXCEEDING 2.4 m.
5.HDPE PIPE SHALL BE SUPPORT AT A SPACING NOT EXCEEDING 1.8 m.

10

250

150x75x6.5

19

44x6

250x250x8

1/2

12

12

12

300

150x75x6.5

22

50x6

300x300x8

1/2

12

12

14

350

150x75x6.5

22

50x6

300x300x8

1/2

12

12

16

400

150x75x6.5

22

63x6

300x300x8

1/2

12

12

18

450

150x75x6.5

25

63x6

300x300x8

1/2

12

12

20

500

150x75x6.5

25

75x9

300x300x8

1/2

12

12

24

600

200x80x7.5

25

75x9

300x300x8

1/2

12

12

30

750

200x80x7.5

25

75x9

300x300x8

1/2

12

12

TITLE

TYPICAL DETAIL NO.1


DRAWING NUMBER
PROJECT No.

WBS

TYPE

DISC

NUMBER

REV

235449

0001