You are on page 1of 12

EPICC FOR WASTEWATER RECYCLE

AND REDUCTION PROJECT


(QG2 AND QG3&4)
VENDOR/ SUBCONTRACTOR DOCUMENT NO: VP-THI-QG59-130

REVISION: C2

DOCUMENT TITLE: DATA SHEET FOR MAIN MOTOR (QG3&4)

Page 1/12

DATA SHEET FOR MAIN MOTOR (QG3&4)

C2

24th Dec.
2015

SJK

SAFI

CJL

FOR APPROVAL

C1

26th Nov.
2015

SJK

SAFI

CJL

FOR APPROVAL

Revision

Date

Originated

Checked

Approved

Description

EPICC FOR WASTEWATER RECYCLE


AND REDUCTION PROJECT
(QG2 AND QG3&4)
CONTRACTOR PROJECT NO: MQAE622
CLIENT DOCUMENT NO: 424/59/00/EL/DS/NA/000108

CONTRACT NO: LTC/VEN/2194/13


DOC. CLASS:

CONTRACTOR DOCUMENT NO: MQAE622-KBE-1023

DOCUMENT TITLE: DATA SHEET FOR LOW VOLTAGE MOTOR -QG3&4 WRR

REVISION: 00

PAGE: 2 OF 5

TABLE OF CONTENTS

SL. NO.

DESCRIPTION

PAGE

APPLICABLE STANDARD SPECIFICATION

QUANTITY

ENVIRONMENTAL CONDITIONS

POWER SYSTEM DETAILS

DRIVEN MACHINE DATA

TECHNICAL DATA

ACCESSORIES

FACTORY TESTING REQUIREMENTS

DATA TO BE FURNISHED BY MOTOR MANUFACTURER

3&4

EPICC FOR WASTEWATER RECYCLE AND


REDUCTION PROJECT
(QG2 AND QG3&4)
CONTRACTOR PROJECT NO: MQAE622
CLIENT DOCUMENT NO: 424/59/00/EL/DS/NA/000108

CONTRACT NO: LTC/VEN/2194/13


DOC. CLASS:

CONTRACTOR DOCUMENT NO: MQAE622-KBE-1023

DOCUMENT TITLE: DATA SHEET FOR LOW VOLTAGE MOTOR -QG3&4 WRR

SL. NO.

DESCRIPTION

1.0

APPLICABLE STANDARD SPECIFICATION

1.1

QG Specification to Comply

1.2

International Standards

2.0

QUANTITY

3.0
3.1
3.2
3.3
3.4
3.5

ENVIRONMENTAL CONDITIONS
Location
Ambient air temperature (Min. / Max.)
Deisgn Ambient temperature
Humidity (at all temperatures)
Altitude

3.6

Hazardous area classification

4.0
4.1
4.2
4.3
4.4

POWER SYSTEM DETAILS


System Voltage & Variation
System Frequency & Variation
Type of Starting
System Neutral Earthing

5.0
5.1
5.2
5.3
5.4
5.5

DRIVEN MACHINE DATA


Type
Rated power
Speed
Type of Coupling
Moment of Intertia (GD2) Value
Starting/Operating condition (Closed Discharge/Open
Discharge)

5.6

6.0
6.1
6.2
6.3
6.4

TECHNICAL DATA
Duty
Service Factor
Rated Speed
Type of Protection

6.5

Enclosure ingress protection

6.6
6.7
6.8
6.9
6.10
6.11
6.12
6.13
6.14
6.15

Efficiency class
Mechanical Shock Protection Rating
Stator Winding
No of power terminals
Tropicalisation
Rotor Type
Insulation Class
Temperature rise Class
Direction of Rotation
Mounting Arrangement

6.16

Type of Construction

6.17
6.18
6.19

Vibration
Vibration Monitoring
Noise Level

6.20

Thrust

7.0

ACCESSORIES

7.1

Base Plate

7.2
7.3

Winding and Bearing Temperature detectors


Condensed Water Drain holes on frame

UNITS

REVISION: 00

PROJECT REQUIREMENT

PAGE 3 OF 5

VENDOR DATA

QCS/50/00/EL/TS/NA/012,
QCS/50/00/EL/TS/NA/003,
IEC 60034, IEC 60079, IEC 60072
EN 50014 through 50020
ISO 9000 ISO 9004
nos.

C
C
%
m

kV
Hz

kW
rpm

rpm

As Required

Outdoor Onshore, Severe Corrosive


4 / 50
50
100
<1000
As per Material Requisition
(All motors shall be suitable for minimum Zone
2 classification )
For Zone1, Motor Enclosure: Ex d in IIA/B T3 &
Terminal box Enclosure: Ex e in IIA/B T3.
For Zone2, Motor Enclosure: Ex n in IIA/B T3 &
Terminal box Enclosure: Ex n in IIA/B T3

4 / 50
50
100
<1000
For Zone2, Motor Enclosure: Ex n
in IIA/B T3 &
Terminal box Enclosure: Ex n in
IIA/B T3

415 V 10%, 3 Phase, 3 Wire


50 5%
DOL
High Resistance Earthed

415 V 10%, 3 Phase, 3 Wire


50 5%
DOL
Not motor vendor's scope

VTA
VTA
VTA
VTA
VTA

Not motor vendor's scope


Not motor vendor's scope
Not motor vendor's scope
Not motor vendor's scope
Not motor vendor's scope

VTA

Not motor vendor's scope

As per Material Requisition


1
To Suit driven equipment
As per SL. No. 3.6
Minimum IP55W
(IP68W for Submerged electric motors)
EFF1 (High Efficiency)
Suitable for Driven Equipment
Copper
3
Required
Manufacturer Standard
F
B
To Suit driven equipment
To Suit driven equipment

S1
1
2969
Ex n

Totally Enclosed Fan Cooled(TEFC) / Totally


Enclosed Forced Ventilation (TEFV)

db

Within the Limits Specified in 'IEC 60034'


Not Required
Not more than 85db at 1m
Maximum Thrust, To be advised by driven
equipment Manufacturer

As per company specification


QCS/50/00/EL/TS/NA/012
N/A
N/A

IP55
IE2
N/A
Confirmed
6
Confirmed
Confirmed
F
B
Confirmed
Confirmed
Confirmed
Grade A
N/A
77 + 3 dB(A)
N/A

Provided by driven equipment


N/A
N/A

EPICC FOR WASTEWATER RECYCLE AND


REDUCTION PROJECT
(QG2 AND QG3&4)
CONTRACTOR PROJECT NO: MQAE622
CLIENT DOCUMENT NO: 424/59/00/EL/DS/NA/000108

CONTRACT NO: LTC/VEN/2194/13


DOC. CLASS:

CONTRACTOR DOCUMENT NO: MQAE622-KBE-1023

DOCUMENT TITLE: DATA SHEET FOR LOW VOLTAGE MOTOR -QG3&4 WRR

SL. NO.
7.4

DESCRIPTION

UNITS

Rating Plate

7.5

Earthing Boss

7.6
7.7
7.8
7.9
7.10
7.11
7.12
7.13

Lifing eye Bolts


Anti-condensation heater
Terminal Box
Terminal Box Fault rating
Cable Glands
Type of Cable Glands
Power Cable Size
Anti-Condensation Heater Cable Size

7.14

Painting

8.0

FACTORY TESTING REQUIREMENTS

DATA TO BE FURNISHED BY MOTOR


MANUFACTURER
Manufacturer
9.1
Motor Frame Size
9.2
Full Load speed
9.3
9.4
Efficiency
9.4.1 At full load
9.4.2 At 75% load
9.4.3 At 50% load
9.5
Power Factor
9.5.1 Starting
9.5.2 At full load
9.5.3 At 75% load
9.5.4 At 50% Load
9.6
Current
9.6.1 At Full load and 100% Voltage
9.6.2 At Full load and 110% Voltage
9.6.3 At Full load and 80% Voltage
9.6.4 Locked rotor Current
9.7
Locked rotor withstand time
9.7.1 Cold Condition
9.7.2 Hot condition
9.8
Torque (Full load)
9.8.1 Locked Rotor
9.8.2 Starting
9.8.3 Pull-up
9.8.4 Pull-in
9.8.5 Pull-out
9.8.6 Breakdown
9.9
Symmetrical Contribution to 3 Phase Terminal Fault
9.9.1 1/2 Cycle
9.9.2 5 Cycle
9.10 Reactance
9.10.1 X" d
9.10.2 X' d
9.10.3 Xd
9.11 kVA inrush at full voltage and Locked Rotor
9.12 kVA at full voltage & 95% Speed
9.13 Acceleration time at rated voltage for motor

REVISION: 00

PAGE 4 OF 5

PROJECT REQUIREMENT

VENDOR DATA

Stainless Steel Grade 316

Confirmed

In motor terminal Box and on the motor


frame

Confirmed

Required
Required for 37 kW
Adjustable
VTA
By Purchaser (Size will be informed later)
Ex e Type
Note : Cable Sizes will be informed later
(Size will be informed later if required)
As per Cl. 11 of Company Specification
QCS/50/00/EL/TS/NA/012

Confirmed
Confirmed
Top / 4x90 Rotatable
30kA x 0.1s
2xM63
Confirmed
Not motor vendor's scope
Not motor vendor's scope
Confirmed

As per Company Specification


QCS/50/00/EL/TS/NA/012

Confirmed

rpm

VTA
VTA
VTA

ABB
280
2969

%
%
%

VTA
VTA
VTA

93.8
93.9
93.1

VTA
VTA
VTA
VTA

0.26
0.90
0.90
0.88

A
A
A
A

VTA
VTA
VTA
VTA

124
112
166
719

Sec
Sec

VTA
VTA

Nm
Nm
Nm
Nm
Nm
Nm

VTA
VTA
VTA
VTA
VTA
VTA

26
13
241
407
407
386
386
578
578

A
A

VTA
VTA

N/A
N/A

Ohm
Ohm
Ohm
kVA
kVA
Sec

VTA
VTA
VTA
VTA
VTA
VTA

0.31
0.44
11.52
86.8
88.9
2.2

9.0

EPICC FOR WASTEWATER RECYCLE AND


REDUCTION PROJECT
(QG2 AND QG3&4)
CONTRACTOR PROJECT NO: MQAE622
CLIENT DOCUMENT NO: 424/59/00/EL/DS/NA/000108

CONTRACT NO: LTC/VEN/2194/13


DOC. CLASS:

CONTRACTOR DOCUMENT NO: MQAE622-KBE-1023

DOCUMENT TITLE: DATA SHEET FOR LOW VOLTAGE MOTOR -QG3&4 WRR

SL. NO.

DESCRIPTION

PAGE 5 OF 5

PROJECT REQUIREMENT

VENDOR DATA

VTA

Bi-directional

Minimum 3
Minimum 2

3
2

Bearings Type

As per Cl. 8.4 of QG Specification


QCS/50/00/EL/TS/NA/012

Confirmed

9.17

Lubrication

As per Cl. 8.4 of QG Specification


QCS/50/00/EL/TS/NA/012

Esso Unirex N2

9.18

Characteristics curves required for following:

Speed torque curve of motor with driven equipment curve


9.18.1 superimposed on the same plot at 80% and 100% of
rated voltage

Required

Confirmed

9.18.2
9.18.3
9.18.4
9.18.5
9.18.6
9.18.7
9.19

Efficiency - Load
Power Factor -Load
Speed -Power factor
Speed-Current
Acceleration
Damage (Hot and Cold withstand) Curve
Total Weight of the Motor

Required
Required
Required
Required
Required
Required
VTA

N/A (only provide motor data)


N/A (only provide motor data)
Confirmed
Confirmed
N/A (Cannot provide exact curve)
Confirmed
665

9.20

General Arrangement drawing fo the motor including


detailed drawing for Each terminal box is to be furnished.

Required

Confirmed

9.14
9.15
9.15.1
9.15.2

Direction of Rotation viewed from coupling end


No. of Starts per Hour
In Cold condidtion
In Hot condition

9.16

UNITS

REVISION: 00

nos.
nos.

kg

0
0

NOTES:
VENDOR shall furnish all the data for Motors and indicate as "N/A" explicitly wherever not applicable.

VENDOR shall furnish relevant catalogues for the respective Motor size and type.

Refer to LV Induction Motor Specification QCS/50/00/EL/TS/NA/012_E1 for additional information.


Cable sizes shall be confirmed during post order engineering.

TBA - To be Advised; VTA - Vendor to Advise; N/A - Not Applicable.

Classifying code or document type

ABB Oy

PERFORMANCE DATA OF MOTOR

Motors
Department/Author

Date of issue

Lang.

GTS/Eric
MLA600/AARA

2015-08-27

En

Rev. date

Our ref.

LKH85634

Customer ref.

Saving Ident

Rev./Changed by

Pages

JZH040815A07/1/A

1106624-1

1/4

Driven Motor:
Motor type code
M3GP 280SMB 2G
Motor product code
3GGP 281220-ADG
Motor type
Squirrel cage Motor
Type of Ex-protection
Ex nA IIC T3 Gc
Mounting designation
IM2001
Protected by enclosure
IP 55
Method of cooling
IC411
Insulation
Class F
Standards
IEC
International efficiency classification (IEC
IE2
60034-30)
Ambient temperature, max.
50 C
Altitude, max.
1000 m.a.s.l.
Duty type
S1
Temp. rise
Class B
Connection of stator winding
Delta
Rated output
75 kW
Voltage
415 V
Frequency
50 Hz
Speed
2969 r/min
Current
124 A
Relat. starting current
5.8
Relat. starting torque
1.69
Relat. maximum torque
2.4
No load current
19.5 A
Rated torque
241 Nm
Load characteristics
Load %
Current A
Efficiency % Power Factor
100
124
93.8
0.90
75
92
93.9
0.90
50
64
93.1
0.88
-All Motor data is subject to tolerances in accordance with IEC.
Efficiency based on typical additional load losses acc. measurements based on IEC 60034-2-1:
2007.

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
Copyright 2013 ABB

Classifying code or document type

ABB Oy

PERFORMANCE DATA OF MOTOR

Motors
Department/Author

Date of issue

Lang.

GTS/Eric
MLA600/AARA

2015-08-27

En

Rev. date

Our ref.

LKH85634

Customer ref.

Saving Ident

Rev./Changed by

Pages

JZH040815A07/1/A

1106624-1

2/4

Motor type code: M3GP 280SMB 2G


Rated output
75 kW
Voltage
415 V
Frequency
50 Hz
Speed
2969 r/min
Current
124 A

Power Factor
Rated torque
Relat. starting current
Relat. starting torque
Relat. maximum torque

0.90
241 Nm
5.8
1.69
2.4

Torque and Current as a Function of Speed

I/In

2,5

1,5 T/Tn

0,5

0
0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

n/ns
I, U=100%
T, U=100%

I, U=80%
T, U=80%

Load Torque

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
Copyright 2013 ABB

Classifying code or document type

ABB Oy

PERFORMANCE DATA OF MOTOR

Motors
Department/Author

Date of issue

Lang.

GTS/Eric
MLA600/AARA

2015-08-27

En

Rev. date

Our ref.

LKH85634

Customer ref.

Saving Ident

Rev./Changed by

Pages

JZH040815A07/1/A

1106624-1

3/4

Motor type code: M3GP 280SMB 2G


Rated output
75 kW
Voltage
415 V
Frequency
50 Hz
Speed
2969 r/min
Current
124 A

Power Factor
Rated torque
Relat. starting current
Relat. starting torque
Relat. maximum torque

0.90
241 Nm
5.8
1.69
2.4

Power Factor as a Function of Speed


1

0,9

0,8

0,7

0,6

PF 0,5

0,4

0,3

0,2

0,1

0
0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

n/ns

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
Copyright 2013 ABB

Classifying code or document type

ABB Oy

PERFORMANCE DATA OF MOTOR

Motors
Department/Author

Date of issue

Lang.

GTS/Eric
MLA600/AARA

2015-08-27

En

Rev. date

Our ref.

LKH85634

Customer ref.

Saving Ident

Rev./Changed by

Pages

JZH040815A07/1/A

1106624-1

4/4

Motor type code: M3GP 280SMB 2G


Rated output
75 kW
Voltage
415 V
Frequency
50 Hz
Speed
2969 r/min
Current
124 A

Power Factor
Rated torque
Relat. starting current
Relat. starting torque
Relat. maximum torque

0.90
241 Nm
5.8
1.69
2.4

Time - Current and Thermal Limit Curves


10000

1000

Time [s]

100

10

0,1
1

Stator current / Rated current


Running (cold)
Running (w arm)

Locked (cold)
Locked (w arm)

Time-current, U = 100%
Time-current, U = 80%

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.
Copyright 2013 ABB

Aux-box for space


heater

Additional information:

Dimension Print

Motor Type:

Document No:

M3BP 280SM_2 B35,V15,V36

3GZC500028-219 A

M3GP/HP 280SM_2 B35,V36

14 BP 280 A

Description:

SQUIRREL CAGE MOTOR WITH TERMINAL BOX 210 AND AUXILIARY


TERMINAL BOX (CAST IRON)

Unit:

ABB Ltd., Motors and Generators

Issued by:

Anderson Gu

Replaces:

Date:

2015-12-03

Approved by:

Hanson Feng

Replaced by:

Customer Reference:

ABB Ltd.

Comment:

Dimension Print

Motor Type:

Document No:

M3BP/GP/HP 280

3GZF500728-49 B
13 BP 280 ZW

Description:

Terminal box 210/1

Unit:

Electrical Machines / LV Motors

Issued by:

K.Edsvik

Replaces:

Date:

01.10.2002

Approved by:

M.Sevola

Replaced by:

ABB Oy

Customer Reference:

!
"
# $ $

%& !'! & &' ( !) *+ ,-!% ('* ./

0 $
1

/
- #

' 9

(##

23

7 23

-/4561

'

81

/4$$ 1

'

81

23

You might also like