You are on page 1of 10

PV System Load Estimation Worksheet

Individual Loads
CFL
E/S Fridge
Clothes Washer
Gas Dryer
TV
VCR
Laptop Computer
Microwave
Test

Qty
15
1
1
1
1
1
1
1
1

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

AC
Volts
120
120
120
120
120
120
120
120
120

DC
Volts

X
Amps
=
Watts AC
X
0.125
=
225.00
X
1.058
=
126.96
X
12.09
=
1450.80
X
2.5
=
300.00
X
1.09
=
130.80
X
0.33
=
39.60
X
0.33
=
39.60
X
11.66
=
1399.20
X
0
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
X
=
0.00
AC Total Connected Watts: 3711.96
DC Total Connected Watts:

Watts
DC
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Use
Hrs /Day
4
9
0.5
1
4
2
8
0.082
0

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Use
Days /Wk
7
7
4
4
7
3
5
7
0

7 Days =

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=

7
=
AC Average Daily Load:
AC kWh / Month:
DC Average Da
DC kWh / Month:

PV System Battery Sizing Worksheet


AC Average Daily
Load (wt-hr/day)

Inverter
Efficiencey

DC Average Daily
Load (wt-hr/day)

DC System
Voltage

Average Amp
hours/day

3526.75

0.90

0.00

48

81.64

Days of
Autonomy

% Discharge Limit
on Battery

Battery AH
Capacity

Batteries in
Parallel

81.64

0.50

350

DC Voltage System

Battery
Voltage

Batteries in Series

Batteries in
Parallel

Total
Batteries

48

14.92802

Average Amp-hours
/day

PV Panel Array Sizing Worksheet


Average Amp-Hrs /
day

Battery
Efficiencey

Peak Sun Hrs/day

Array Peak
Amps

81.64

0.80

4.10

24.89

Array Peak Amps

Peak Amps /
Module

24.89

5.02

5.0

DC Voltage System

Nominal
Module
Voltage

Modules in Series

Modules in
Parallel

Total
Modules

48.00

12

4.00

20.00

Panel Specification

Modules in
Parallel

Make:

Module Short
Circuit Current

5.34

Model:

PV Controller Sizing Worksheet


Module Short
Circuit Current

Modules in
Parallel

1.25

Array Short
Circuit Amps

5.34

5.0

1.25

33.38

DC Total Connected
Watts

DC System
Voltage

0.00

48

Controller Specification

Maximum DC
Load Amps

Controller
Array Amps

40.0

Controller
Load Amps

0.0

Make:

Model:

PV Inverter Sizing Worksheet


AC Total Connected
Watts

DC System Voltage

Estimated Surge
Watts (In Rush
=Min of 3-6 times
Total Connected
Watts )

3711.96

48

11135.88

Inverter Specification

Make:

Model:

Listed D
Featu

Tem
Compen
digtal Vo

Watt Hours
Watt
AC
Hours DC
900.00
0.00
1142.64
0.00
414.51
0.00
171.43
0.00
523.20
0.00
33.94
0.00
226.29
0.00
114.73
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
3526.75
105.80
rage Daily Load:
0.00
0