You are on page 1of 17

Measurement

Piling Works

(A)

PRE-FORMED CONCRETE PILES

Specification Notes on precast reinforced concrete piles to be


read together with Drawing No. AA/PCP/1.
1. All piles shall be of cross-sectional size 200mm x 200mm.
2. Supply length of piles shall be:
i. Starter pile 6.oom long
ii. Extension pile 3.00m & 6.00m long
3. Estimated penetration depth : 14.00m
4. No trial pile is required to be installed
5. All pile heads to be cut off by means of hydraulic breaker.
6. Working load : 45 tonnes / pile
7. Allow 4 no. random load tests:
i.

1 no. on 3 pile group

ii. 1 no. on 2 pile group


iii. 2 no. on a single pile
8. Tests shall be carried out in sequence with group testing to be
carried out first. The test load to twice working load shall be
maintained for 24 hours.
9. Legend

DRAWING NO. AA/PCP/2

Taking-off list
1.

Bringing in & removing plant

Item

2.

Maintaining plant on site

Item

3.

Initial piles

No.

4.

Driven depth

5.

Pile extension

No.

6.

Extension piles n.e. 3.00 long

7.

Extension piles exceedg. 3.00


long

8.
9.
10.
11.
12.

Cut off pile heads


Prepare pile heads
Preliminary load tests
Second load tests
Third load tests

No.
No.
Item
Item
Item

10

11

(B)

Interlocking Sheet Piles

12

13

14

15

16

17