You are on page 1of 4

D&C TPH:hf

SECTION 084223
AUTOMATIC DOOR SYSTEMS
PART 1 GENERAL
1.01

1.02

RELATED WORK SPECIFIED ELSEWHERE


A.

Metal Fabrications: Section 055000.

B.

Joint Sealers: Section 079200.

C.

Glass and Glazing: Section 088100.

D.

Wiring for Automatic Sliding Door Systems: Section 260504.

REFERENCES
A.
ANSI/BHMA A156.10 - American National Standard for Power Operated
Pedestrian Doors.

1.03

SUBMITTALS
A.
Waiver of Submittals: The "Waiver of Certain Submittal Requirements"
in Section 013300 does not apply to this Section.
B.
Submittals Package: Submit the shop drawings, product data, and
samples specified below at the same time as a package.
C.

Shop Drawings:
1.
Show fabrication details and connections to adjacent
construction.
2.
Show operators, controls, and other electrical
components.

D.
Product Data: Manufacturer's catalog sheets, specifications, and
installation instructions for door systems.

Updated 12/03/2010
Printed 12/10/2016

E.

Samples:
1.
Color Samples: Manufacturer's standard color range for
finish specified.

F.

Quality Control Submittals:


1.
Installers Qualifications Data: Documentation showing
installer is approved by the door system manufacturer.

G.

Contract Closeout Submittals:


1.
Operation and Maintenance Data: Deliver 2 copies,
covering the installed products, to the Director's Representative.
2.
Systems Acceptance Test Report: Deliver the report to
the Director's Representative.

084223 - 1

Project No.

D&C TPH:hf

1.04

QUALITY ASSURANCE
A.
Installers Qualifications: The firm installing the door systems shall be
approved as an installer by the door system manufacturer.

PART 2 PRODUCTS
2.01

DOOR SYSTEMS
A.
Automatic Sliding Door Systems: Astro-Slide by Dor-O-Matic Division
of Republic Industries, Inc., 7350 West Wilson Ave., Harwood Heights, IL 606564786, Horton Automatics Division of Dallas Corporation, 4242 Baldwin Blvd.,
Corpus Christi, TX 78405, or Dura-Glide Series 3000 by Stanley Magic-Door
Division of The Stanley Works, Route 6 & Hyde Road, Farmington, CT 06032.
1.
Standards: Comply with applicable requirements of
ANSI/BHMA A156-10.
2.
Structural Sections: Aluminum.
3.
Style and Type: Medium stile construction.
a.
Door No. ________: SO-SX, inside
slide.
b.
Door No. ________: SO-SX-SX-SO,
inside slide.
4.
Traffic Pattern: Two way.
5.
Operator: Electro-mechanical, header mounted and
concealed.
a.
Power open and power close.
b.
Adjustable speeds and time delay.
c.
Safety reverser, field adjustable.
d.
Secure locking for slide doors when
power cut off.
6.
Header: Continuous extruded section.
7.
Jambs: Tubular, unless otherwise indicated.
8.
Emergency Egress: Full emergency break out feature on
door panels and sidelight panels, with mechanical self-closing device on
both.
9.
Controls:
a.
Motion detector (sensor) on each side of
door opening.
b.
Push plate switch on each side of door
opening, wall mounted.
1)
Material: Stainless steel
or aluminum.
2)
Material: Brass.
3)
Engraving: Handicap
symbol.
4)
Engraving: Push To
Operate Door.
c.
Two photo-electric/infra-red horizontal
safety holding beams or an overhead infra-red safety threshold

Updated 12/03/2010
Printed 12/10/2016

084223 - 2

Project No.

D&C TPH:hf
area presence sensor. Safety beams/sensor shall shut off when
doors are in the closed position.
10.
Weatherstripping: Manufacturer's standard, around
entire perimeter of doors.
11.
Floor Guides: As required by door type and conditions;
manufacturer's standard.
12.
Aluminum Finish:
a.
Integral Color Anodized Finish: AAM21C22A42, minimum 0.7 mil coating.
1)
Color: Dark bronze.
2)
Color: Matching
existing doors.
b.
Clear Anodized Finish: AA-C22A41,
minimum 0.7 mil coating.
13.
Hardware:
a.
Panic exit device on swing slide doors.
PART 3 EXECUTION
3.01

EXAMINATION
A.
Verification of Conditions: Examine the openings to receive automatic
sliding doors for defects that will adversely affect the execution and quality of the
Work. Do not proceed until unsatisfactory conditions are corrected.

3.02

INSTALLATION
A.
Install the Work of this Section in accordance with the manufacturer's
printed instructions.
B.

3.03

3.04

Install the door systems plumb and level, and rigidly secured in openings.

FIELD QUALITY CONTROL


A.

Preliminary Systems Test: Conduct a preliminary test for the purpose of:
1.
Checking and adjusting the units.
2.
Determining whether the systems are in proper condition
to conduct an acceptance test.

B.

Systems Acceptance Test:


1.
Preparation: Notify the Director's Representative at least
3 working days prior to the test so arrangements can be made to have a
Facility Representative witness the test.
2.
Individually test each unit several times for all functions
of the door systems.
3.
Deliver a report of test results, signed by the Contractor
and the Director's Representative, to the Director's Representative.

ADJUSTING

Updated 12/03/2010
Printed 12/10/2016

084223 - 3

Project No.

D&C TPH:hf
A.
Adjust doors and operators for proper operation and safety. All doors
shall operate at the same speed.
3.05

CLEANING
A.
Clean exposed surfaces. Do not damage finished surfaces during cleaning
operations.

3.06

DEMONSTRATION
A.
Demonstrate each function and operation of the door systems to facility
personnel.
END OF SECTION

Updated 12/03/2010
Printed 12/10/2016

084223 - 4

Project No.