You are on page 1of 6

Auto-Ranging Current to Voltage Converter

Figure: Block Diagram

Kaushal Patel (163079023), Rachit Jain (163079028), Auto


B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

November 22, 2016

1/6

Basic Concept of Operation


The circuit has 2 ranges:
1
2

100A to 1mA
1mA to 10mA

Floating I-V converter converts the current value to single ended


voltage.
Full wave precision rectifier is operating as a magnitude detector. The
output is fed to the auto-ranging circuit.
The auto-ranging circuit mainly consists of a Switchable Gain
amplifier (SGA), along with a Schmitt trigger in feedback which
generates the Switch control voltage to the SGA.
SGA can switch between 2 gains: Gain of 10 for lower range and a
Gain of 1 for higher range.
Schmitt trigger generates control voltage to Switch of SGA based on
Output voltage of SGA relative to a reference voltage.
Kaushal Patel (163079023), Rachit Jain (163079028), Auto
B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

November 22, 2016

2/6

Circuit: Floating Load I-V Converter


500

In+

10K

10K

5K

Out

10K
+

5K

In

10K

500
Kaushal Patel (163079023), Rachit Jain (163079028), Auto
B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

November 22, 2016

3/6

Circuit: Full wave Precision Rectifier

1K

2K

2K

In

1K
+

1.032K

Kaushal Patel (163079023), Rachit Jain (163079028), Auto


B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

Out
+

November 22, 2016

4/6

Circuit: Auto Ranging Circuit


10K
1.2K
10K

In

1.2K

1.2K
+

Ou
+

2.7K
+

1K
+

1.2K

15V
100K

1.2K

15
190K

Kaushal Patel (163079023), Rachit Jain (163079028), Auto


B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

November 22, 2016

5/6

Results and Conclusions


Input Current
Treatment
Treatment
Treatment
Treatment
Treatment
Treatment
Treatment
Treatment
Treatment

1
2
3
1
2
3
1
2
3

MM Reading

LED state

0.0003262
0.0015681
0.0009271
0.0003262
0.0015681
0.0009271
0.0003262
0.0015681
0.0009271

0.562
0.910
0.296
0.562
0.910
0.296
0.562
0.910
0.296

Measured Current

Conclusion
A Dual Auto-Ranging Current to Voltage Converter was implemented
successfully and results were presented.
Kaushal Patel (163079023), Rachit Jain (163079028), Auto
B.S.Teza
ranging
(163074006)
I-V Converter
(IIT Bombay)

November 22, 2016

6/6