You are on page 1of 3

Professional Training and Consultation

API 510- Exam 9-Extra


Closed Book (API RP-577)
Q.1

Recording on a data sheet of an indication that exceeds the reject flaw size
criteria and needs to be corrected isA]
B]
C]
D]

Q.2

A sub surface terrace and step-like crack with basic orientation parallel to
the base metal surface caused by tensile stresses in thickness direction is
called
A]
B]
C]
D]

Q.3

Lamination
Plane-breaking crack
Lamellar tearing
Stress corrosion crack

Slag inclusion is not found in welding performed by


A]
B]
C]
D]

Q.4

Recordable indication
Reportable indication
Notable indication
None of above

SMAW
SAW
FCAW
GMAW

Most applicable method for sub-surface porosity is


A] UT

Q.5

B] PT

C] ET

D] RT

VT is most conveniently performed placing an eye


A]
B]
C]
D]

within 6 24 with angle less than 30 with the surface


within 6-24 with angle not less than 30 with surface
beyond 24 with angle less than 30
beyond 24with angle not less than 30

6th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar,
Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoItc.com www.gotoitc.com

Professional Training and Consultation

Q.6

A clear radiography film has density of


A] 4

Q.7

A- scan shows cross-sectional elevation view


B- scan shows cross-sectional elevation view
C-scan shows cross-sectional elevation view
None of above

Preheating only
Pre-heating & PWHT
No pre- heating or PWHT
PWHT only

A method to assure that PWHT was performed satisfactorily is


A]
B]
C]
D]

Q.10

d] infinity

Steels with CE greater than 0.55% typically require:


A]
B]
C]
D]

Q.9

c] 2

In UT examination,
A]
B]
C]
D]

Q.8

b] 0

Hardness testing of weld & HAZ


Radiography of weld &HAZ
PT or MT of weld &HAZ
UT of weld & haz

Welding process that has very high metal deposition rate is


A]
B]
C]
D]

SMAW
GTAW
GMAW
SAW

6th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar,
Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoItc.com www.gotoitc.com

Professional Training and Consultation

Answer key
EXAM 9 EXTRA
Q. NO.
1
2
3
4
5
6
7
8
9
10

ANSWER
B
C
D
D
B
B
B
B
A
D

6th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar,