You are on page 1of 1

Project:

Owner:

TWOSTOREYRESIDENTIAL
BUILDING

Subject:
CalculatedBy:

Mark
CheckedBy: Date:

F1
Page
1of3

StrapFooting

Mr.andMrs.IsabeloDelosSantos

DESIGNOFASTRAPFOOTING
(inaccordancewithNSCP2001Vol.15thedition)
FOOTINGDETAILS:
FOOTINGMARK=
ColumnWidth(alongXAxis)=
ColumnWidth(alongZAxis)=
ConcreteClearCovercc=
FlexuralReinforcement(alongXAxis)=
FlexuralReinforcement(alongZAxis)=
AssumedFootingWidthW=
AssumedfootingLengthL=
AssumedFootingThicknesst=

F1
350
350
75
16
16
1700
1700
250

MATERIALDETAILS/SPECIFICATION
Concretecompressivestrengthfc'=
1 =
SteelStrengthforMainBarsfy =
ConcreteDensityycon=

21
0.85
275
24

Mpa

SOILDETAILS/SPECIFICATION
SoilBearingCapacitySBC=
SoilDensityYsoil=
DepthofFootingBaseD=

140
15.7
1.5

Kpa
KN/cu.m
m

301

KN
KNm
KNm

DESIGNLOADSFROMANALYSIS
ComputedmaxworkingAxialLoadPw=
ComputedmaxworkingMoments,Mwx=
ComputedmaxworkingMoments,Mwz=
ComputedUltimateAxialLoadPu=
ComputedUltimateMoments,Mux=
ComputedUltimateMoments,Muz=

403

mm
mm
mm
mm
mm
mm
mm
mm

SBCeff>qa,dimensionsok!
eact<L/6,ok!
eact<L/6,ok!

footingthicknessissafeagainstbending!
footingthicknessissafeforbeamshear!
footingthicknessissafeforpunchingshear!

Mpa
KN/cu.m

wtoffootingwt=

Pwtotal=

17.01
318.01

KN
KNm
KNm

checkeactatxdir=
checkeactatzdir=
eminatxdir=
eminatzdir=

0.00
0.00
35.00
35.00

mm
mm
mm
mm

TRIALFOOTINGDIMENSION
tryfootingdimension=
tryfootingthickness=

1700
250

x
mm

eact<L/6,ok!
eact<L/6,ok!

L/6=
L/6=

momentcanbeneglected!
momentcanbeneglected!

1700

283.33
283.33

You might also like