You are on page 1of 52

HB

Hohmann & Barnard, Inc.


Design & Fabrication of Stone Support and Masonry Anchor Systems
Table of Contents
Lox-All Truss & Ladder Reinforcement Who ever said, its not easy being green?
Just look for the green dots throughout the
#120 - #150 Truss / #220 - #250 Ladder A4 catalog for info on recycled content.

#165 & #170 Adjustable Truss A5


#265 & #270 Adjustable Ladder A5 Aluminum Brick Vents A22
Adjustable Wall Ties SH-Seismic Hook A5 Concrete Inserts A23
Adjustable Anchor Systems Sharktooth Inserts A24-A25
#180 / #280 Dub'I Loop-Lok Reinforcement A6 Repair & Restoration Anchors
Mighty-Lok A7 #520, #521RA-B & #522RA A26
#185 / #285 Grip-Lok Reinforcement A7 Helix Spiro-Ties A27
Tie-2R Tie-HVR-190V A8 Stone Anchors & Accessories A28
Tie-HVR-195V Tie-HVR-195VB A8
Flashing Systems
Veneer Anchor Systems
Flex-Flash B2
HB-200, HB-200-X, HB-200-HS A9
Flex-Flash Drip Edge, Corners & End Dams B3
X-Seal Anchor / X-Seal Tape A10
Textroflash Green Textroflash B4
DW-10HS A10
Flash-N-Drain - Coming Soon B5
2-Seal Tie / Concrete Seal Tie A11
Copper-Tuff & Copper-Flex B6
2-Seal Byna-Lok Wire Tie A11
Epra-Max B7
Seismic Anchor Systems
C-Fab & C-Kraft Duplex Flashings B7
Seismiclip Interlock System (S.I.S.) A12
Asphalt Mastic B7
Byna-Lok Wire Tie / Continuous Wire A13
Metal Flashings & Accessories B8
Screws A12
Drip Plates & DP Corners B9
Seismic Veneer Anchors
Concrete & Masonry Reglet B10
#303 SV, #345 SV, #364 SV & T-Lok Tie A14
Termination Bar Splice Tape B10
Channel-Tee Seismic-Notch System A14
Residential
Wall Ties And Anchors
Window Products C2
Vee-Byna Tie #303, #315, A15
Wrap-N-Seal, Stretch-N-Seal Top-Seal Tape C2
#344 #345 & #345-BT A15
Roofing Products C3
#301W & #302W A16
Roofing Underlayment & Trac-Seal C3
#359, #359-C, #359FP, #359FP-C #359FH A16
Copper Termite Shield Mite-Out Sill Seal C4
Column And Beam Anchors
#351, #352, #353, #353L, #354, #355L & #357 A17 Air Barrier Systems

Gripstay Anchor Systems H&B Commercial Air Barrier D2


#360 - #362, #362-C, #362-CX, #363 #364, #365 A18 H&B Residential Air Barrier D3
Miscellaneous Accessories Textroflash Liquid - Air & Vapor Barrier D4-5
Spyra-Lox RB & RB-Twin Slip-Set A19 Textroflash Liquid VP - Air Barrier D6-7
Corrugated Wall Tie, Mesh Wall Tie & Mortar Grout Screen A19 H&B Self-Adhering Air & Vapor Barrier D8
Control Joints Weep Holes Mortar Net A21 H&B Transition Membrane D8
PTA Series Partition Top Anchors A20

IMPORTANT: Since each construction project is unique, the appropriate selection and use of any product contained here-in must be determined
by competent architects, engineers and other appropriate professionals who are familiar with the specific requirements of the project in question.

WWW.H-B.COM H&B manufactures steel wire products from a minimum of 95 %


post-consumer recycled material.
Section A - Masonry Systems

Lox All Reinforcement


TRUSS Type
#120 Truss-Mesh #130 Truss-Tri-Mesh #140 Truss-Twin-Mesh #150 Truss-Box-Mesh
Single Wythe Wall Composite Wall Composite Wall Composite Wall

LADDER Type
#220 Ladder-Mesh #230 Ladder-Tri-Mesh #240 Ladder-Twin-Mesh #250 Ladder-Box-Mesh
Single Wythe Wall Composite Wall Composite Wall Composite Wall

Hohmann & Barnards Lox-All Truss-Mesh and Ladder-Mesh are continuous lengths
of joint reinforcement that are embedded into the horizontal mortar joint of masonry
walls. Joint reinforcement has long proven to be necessary for superior performance Standard Sizes:
of masonry wall construction. 4 wall - 16 wall. Other widths
available on special request.
Benefits:
. Greatly reduces cracking that can arise from thermal stresses. This enhances (S) Standard:
9 ga. side rods x 9 ga. cross rods
resistance to water penetration, as cracks are controlled.
. Increases lateral flexural strength. (EH) Extra Heavy:

. Bonds exterior and interior masonry wythes together in composite or cavity 3/16 side rods x 9 ga. cross rods
(SHD) Super Heavy Duty:
walls. Also bonds masonry at intersecting walls and corners. 3/16 side rods x 3/16 cross rods
. Increases elasticity and performance of masonry walls under various stresses. Finishes: Mill Galv, Hot Galv or
Features: Stainless Steel
. Butt-welding of cross rods to longitudinal rods (not more than 16o.c.). This con-
struction enhances bonding capabilities, eliminates projection of cross rods H&B products conform to ASTM
beyond the specified width of reinforcement, and prevents excessive build up of A951 standard specification for
wire in limited mortar joints. masonry joint reinforcement.
. Continuous deformation along each longitudinal rod for superior bonding perfor-
mance.

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

A4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Lox All Adjustable Reinforcement
TRUSS Type H&B manufactures steel wire products from a minimum of 95 %

recycled material.
#165 Adjustable Truss #170 Truss LOX ALL Stainless Steel recycled content see page 28.
Cavity / Insulated Wall Adjustable Eye-Wire
#165 & #265 - have winged loops welded to the back-up
reinforcing. The loops accept pintles to allow vertical ad-
justability while restraining transverse movement of the
two wythes. Suitable for collar joint conditions, cavity walls or
insulated walls.

#170 & #270 LOX ALL Adjustable Eye-Wire


.. Same features as above, with eyelets in lieu of loops.
Pintle drops into snug eyelet as exterior wall is erected,

. Allows
tying both wythes together.
construction of interior wythe in advance of

LADDER Type . Special design of pintle serves to mechanically secure


exterior wythe.

insulation to the masonry back-up.


#265 Adjustable Ladder #270 Ladder LOX ALL
Cavity / Insulated Wall Adjustable Eye-Wire
Standard Sizes: 4 wall - 16 wall. Other widths available
on special request. Adjustable reinforcing made to ac-
commodate various insulation / air dimensions. Eyes and
Pintles are 3/16 dia.
(S) Standard: 9 ga. side rods x 9 ga. cross rods
(EH) Extra Heavy: 3/16 side rods x 9 ga. cross rods
(SHD) Super Heavy Duty: 3/16 side rods x 3/16 cross rods

Finishes: Mill Galv


Hot Galv
Stainless Steel

Adjustable Wall Ties


Standard Sizes: Finishes:
Mill Galv
PINTLE SECTION EYE SECTION
Hot Galv
TIE NO. SIZE TIE NO. SIZE
Stainless Steel
300H 3 275E 2-3/4
400H 4 350E 3-1/2
475H 4-3/4 475E 4-3/4
525H 5-1/4 575E 5-3/4

NEW
Now you can adapt any of the adjustable systems shown
NOW AVAILABLE...
above for seismic zones by specifying the H&B SH -
SH - SEISMIC HOOK Seismic Hook. This hook is swaged (indented) in two
places to accommodate either a 9 gauge or 3/16 continuous
wire. As shown, a channel is formed that braces the continu-
ous wire and holds it in place. Suitable for standard 3/8 joints.
Specify SH Seismic Hook with any adjustable wire, such as
#170-SH.

shown with U.S. Pat. No. 6,789,365 & 7,325,366


continuous wire Other Patents Pending

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A5
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Adjustable Reinforcement Systems


#180-BL DUBL LOOP-LOKTM TRUSS U.S. Patents 5,408,798,
with Byna-Lok Wire Tie 5,454,200, 6,279,283,
6,668,505, 6,789,365,
6,851,239, 6,925,768
Dubl Loop-Lok Features: Other Patents Pending

100% protection against separation of wire tie from reinforce-


ment. (See ACI 530 Bldg. Code Sec. 6.2.2.5.5.3)
Allows in-plane vertical and horizontal movement of masonry
wythes while restraining tension and compression.
Loops welded shut to maintain allowable tolerance and sys-
tem integrity.
Unlike horizontal eyelets, vertical loops will not clog with
mortar as construction progresses.
Loop extends one direction only to allow simple placement of
insulation. Slip on Loop-LokTM Washer to mechanically lock
insulation in place

Also available in Ladder Style # 280-BL


Optional Feature! Special Loop with 2-1/2 vertical adjustability.
Ideal for Econo or Utility Bricks. Request when ordering.

Byna-Lok Features: (see additional info on page 13)


Swage and mild pitch on legs of the Byna-Lok Wire Tie provide an integral track for the continuous joint reinforcement wire.
Economical. Add continuous wire to masonry walls at little additional cost.
Suitable for standard 3/8" mortar joint.
The use of continuous wire in the outer brick wythe is beneficial in providing protection against problems arising from ther-
mal expansion and contraction (crack control). It also allows for a more uniform distribution of lateral forces. Suitable for
Seismic Zones.

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

1. 3/16 BYNA-LOK WIRE TIE #180-BL #180 S.I.S.


(STANDARD)

2. 9 GA. OR 3/16
CONTINUOUS WIRE 1 3

3. 3/16 BOX BYNA-TIE


(STANDARD)

4. SEISMICLIP

5. LOOP-LOKTM WASHER
(OPTIONAL )
2 4 5

Dubl Loop-LokTM systems are available without the Seismiclip Interlock System.
Specify product #180 (truss type) or #280 (ladder type).

A6 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Adjustable Reinforcement Systems

MIGHTY-LOKTM

The new Mighty-LokTM adjustable joint reinforcement features super-


heavy-duty eyelets and pintles for superior strength and performance.
This is especially beneficial for todays multi-wythe construction with
extra-wide cavity walls or when mortar joints are not in close align-
ment. With H&Bs new Tru-JointTM feature, the large diameter pintles
are factory-flattened and serrated to allow masons to easily maintain
a standard 3/8 joint thickness.

Features:
Large diameter eyelets and pintles afford usage where high
strength requirements are present and standard eyelets and
pintles would fail (including extra-wide cavity conditions). Also
designed for usage where standard eyelets and pintles would
fail due to greater than normal misalignment of mortar joints
between the 2 wythes.

Rounded eyelets engage pintles snugly in conformance with


existing codes (less than 1/16 mechanical play). No oblong-
shaped eyelets as found on other systems.

Pintles are flattened and serrated for superior bonding with


U.S. Patent No.
mortar. 6,279,283
6,668,505.
Available Truss style (#170-ML) or Ladder style (#270-ML). Other Patents Pending.

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

#185 GRIP-LOKTM TRUSS

Features:
Combines Dubl Loop-LokTM Truss reinforcement with interlocking
Grip-Lok Plate. Plate accepts continuous joint reinforcing wire.

Loops welded shut to maintain allowable tolerance and system


integrity.

Allows in-plane vertical and horizontal movement of masonry


wythes while restraining tension and compression.

Grip-Lok T-Head configured to allow simple engagement into Loop-


Lok, yet disengagement is prevented.
Also available:
#285 Grip-LokTM Ladder Heavy-duty Grip-Lok Plate accepts 9 gauge or 3/16 diameter con-
tinuous horizontal wire.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A7
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Adjustable Anchor Systems for Rubble Stone

Tie-2R Anchor System


This anchor system for rubble stone walls with masonry backup allows the mason to
place anchors where they are needed. The joint reinforcement has 9 ga. deformed
side rods, a 3/16 dia. cross rod and a 1/4 dia. heavy duty side rod projecting into
the cavity. To this rod the stone mason attaches HELICAL HOOK ANCHORS with
an easy twist.
Anchor Type HS is for horizontal joints and Type HP for vertical joints. Thus, the
mason can fit the ties to the wall rather than having to build the wall to fit the ties.
In addition, rigid insulation is easily applied between the wythes.
Finishes: Hot Galv
Stainless Steel

Type HS for use Type HP for use


in horizontal joints in vertical joints

Tie-HVR-190V Anchor System


In this system, the backup is reinforced with truss type reinforcement. The mason
then places the vertical rod into the cavity by hooking onto the extended truss cross
rod. Rubble stone can then be tied easily to the backup using standard Vee Byna-
Ties. Horizontal mortar joints do not have to align.
Tie-HVR-190V is for filled cavity conditions.

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

Tie-HVR-195V Anchor System


Tie-HVR-195V is for use with cavity or insulated walls. The flexible masonry tie has
a pre-drilled hole to accept a vertical J-Hook. This configuration prevents in-and-
out movement of the masonry tie, while allowing maximum vertical adjustability.
This allows the mason to place the tie wherever the horizontal mortar joint lies.
Available for any wall size. State block, insulation, cavity and rubble stone sizes
when ordering. Ladder style also available (Product Tie-HVR-295V).

Tie-HVR-Series truss or ladder reinforcement availability:


(S) Standard: 9 ga. side rods x 9 ga. cross rods
(EH) Extra Heavy: 3/16 side rods x 9 ga. cross rods
(SHD) Super Heavy Duty: 3/16 side rods x 3/16 cross rods
Projecting box portion (195V or 295V) available 9 ga. or 3/16 dia.
Finishes: Hot Galv
Stainless Steel

Tie-HVR-195VB Anchor System


Tie-HVR-195VB is ideal for use on concrete backup, or when masonry backup is
already in place, and new veneer is being installed. The L-shaped plate is sized for
any thickness of insulation, and has a slotted hole to accept the vertical J-Hook.
The flexible masonry tie is the same as used with Tie-HVR-195V, as described
above. State insulation, cavity and rubble stone sizes when ordering.

A8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
HB-200 Systems
6
HB-200 5
Veneer Anchor System
1

4
2
Shown with Pintle,
Seismiclip & Continuous Wire

3
1. HB-200 ANCHOR
2. HB-200 PINTLE
HB-200 - 14 ga. or 12 ga. thick. Backplate portion made to accommodate
0 - 4 insulation thickness. Pintle portion available 3, 4, 4-3/4 or 5-1/4 3. INSULATION
long. Other sizes available upon request. 4. RIGID WALLBOARD
5. H&B SELF-DRILL / SELF-TAP SCREW
Finishes: Hot Galv
Stainless Steel 6. STEEL STUD

HB-200-X
Veneer Anchor System

Similar to the HB-200 anchor shown above, but with


three pronged punchouts that project from the back
of the anchor. The prongs prevent positive wind-
loads from crushing the wallboard by transferring
theses loads back to the stud.
Available to accommodate 0- 4 insulation thickness. Pintle portion available 3, 4, 4-3/4
or 5-1/4 long. Hot Dip Galvanized or Type 304 Stainless Steel. Patents Pending

HB-200-HS
High-Strength Veneer Anchor System
Now available for heavy-duty applications, our new HB-200-HS High-Strength Veneer
Anchor System incorporates a 1/4" diameter pintle. This heavy-duty pintle is flattened
and then serrated for superior bonding with mortar. Suitable for 3/8" mortar joints.

Ideal for usage when the offset of engagement between pintle and anchor is
greater than 1-1/4". Standard leg length will accommodate up to 2" offset while
maintaining sufficient strength. Longer leg lengths are available on special
order, subject to loading requirements. (Note: ACI 530 section 6.2 indicates
maximum offset of 1-1/4" for standard 3/16" diameter pintle.)
Also ideal for wide cavity conditions, where a standard 3/16" pintle would not
satisfy load requirements. (Note: ACI 530 section 6.2 indicates maximum allow-
able span of 4-1/2" for standard 3/16" diameter pintles.)

U.S. Patent No. 6,279,283 Please contact H&Bs technical department for further information.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A9
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

X-Seal Veneer Anchor


X-SEAL ANCHOR
CAPABLE OF WITHSTANDING A
The X-SEAL Anchor is the next generation 100# LOAD IN BOTH TENSION
veneer anchor from H&B. The X-SEAL Anchor NEW FEATURE! AND COMPRESSION WITHOUT
improves upon the original DW-10-X by moving PATENTED LEG DESIGN DEFORMING OR DEVELOPING
ALLOWS BACKPLATE TO PLAY IN EXCESS OF 0.05.
the horizontal pronged legs in from each end, SEAL SHEATHING FROM
enabling the backplate portion of the anchor AIR & MOISTURE INFILTRA-
100% PROTECTION AGAINST
to effectively seal the wall-board / insulation. This TION WHILE MAINTAINING
SEPARATION OF WIRE TIE FROM
INTEGRITY OF THE VAPOR
helps to maintain the integrity of the vapor bar- BARRIER. ANCHOR (See ACI-530-02 Sec.
rier and prevents the ingress of air and moisture 6.2.2.5.5.3)

through the sheathing. The pronged legs bridge ANCHORS AND SCREWS ARE
the sheathing and abut the steel stud, affording INSTALLED BEFORE THE FIRST
BRICK IS LAID, IMPORTANT FOR
independent, positive anchorage. Compression ON-SITE VISUAL INSPECTION.
of the sheathing by positive loads is also
prevented. The pronged legs are now also rib-
stiffened and oriented closer to each other than AVAILABLE IN LEG LENGTHS
TO ACCOMMODATE 1 / 2 -
on the original DW-10-X, thus enhancing the 4-1/2 WALLBOARD / INSU-
compressive strength. Owners, architects and LATION, HOT DIP GALV. OR
TYPE 304 ST/ STEEL.
masons can be confident in the performance
of an X-SEALED metal stud /veneer wall.

The X-SEAL Anchor meets or exceeds U.S. Pats. CAN BE INSTALLED ON LARGE
requirements of the Commonwealth of 6,925,768 & 6,941,717 4 X 8 INSULATION BOARDS, RE-
DUCING HORIZONTAL JOINT SEAMS
Massachusetts State Building Code Canadian Patent BY TWO-THIRDS (FURTHER RE-
for air leakage and water penetration. Con- 2,458,008 DUCING POTENTIAL FOR AIR &
MOISTURE INFILTRATION)
tact H& B's technical dept. for test results. Other Patents Pending

3
X-SEAL TAPE 2

Now manufactured from 45 %


1. X-SEAL ANCHOR
recycled material.
2. X-SEAL TAPE
1
Self-sealing - Seals around shaft of
screw and legs of X-SEAL Anchor at 3. STEEL STUD
the moment of penetration.
4
4. RIGID WALLBOARD
Durable - Resilient, will not crack or rot.
5. INSULATION
Ease of installation - Adhesive-backed 40-mil rolls 3x 50 ft.
6. H&B SELF-DRILL /
Apply to clean, dry surface. SELF-TAP SCREW
6 5
For maximum performance and adhesion X-SEAL TAPE has
been designed to be applied in continuous lengths only.

Can also be used as an insulation joint tape, as shown below.


DW-10HS
Patents Pending
DW-10HS anchors have all the features
of the X-SEAL as shown, but without the
pronged-leg design. They are primarily for
use when there is no insulation and little
potential for wallboard deterioration.

DW-10HS is 6 long with 3-5/8 vertical


adjustability and furnished with 1/4 dia.
holes. Available 14 ga. or 12 ga. thick, Mill
Galv, Hot Dip Galvanized or Type 304
Stainless Steel.
X-Seal Tape has replaced Textroseal.

A 10 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
2-Seal Tie Veneer Anchor
2-SEAL TIE
An innovative single screw veneer tie for metal stud construction.
Fabricated from carbon steel with a premium quality organic polymer
coating, the 2-Seal Tie has a dual-diameter barrel with factory-
INNOVATIVE DUAL-DIAMETER installed EPDM washers to seal both the face of the insulation and
BARREL AFFORDS A TIGHT SEAL the air / vapor barrier. This is an improvement over single barrel
AT BOTH THE FACE OF INSULA-
TION AND AT THE AIR/ VAPOR
types which only seal at the insulation and render the vapor barrier
BARRIER WITH STEEL-BONDED susceptible to air and moisture infiltration if not precisely installed
EPDM WASHERS (perfectly perpendicular to the stud).

The dual-barrel has an integrated #12 self-drilling screw, and is


HIGH-STRENGTH BARREL FABRI-
CATED FROM CARBON STEEL
available for insulation from 5/8" - 4" thick. The projecting eyelet
WITH PREMIUM QUALITY ORGANIC accepts a 3/16" x 3", 4" or 5" 2-Seal Byna-Lok Wire Tie (see
POLYMER COATING below) for the masonry veneer wall mortar joint. This wire tie is also
adaptable for seismic zones with the simple insertion of 9 ga. or
3/16" diameter continuous wire into the integral track formed by the
NARROWED BARREL PORTION HELPS TO swaged, overlapping legs. Available Hot Galvanized or Type 304
MAINTAIN INTEGRITY OF VAPOR BARRIER Stainless Steel.
COMPARED TO SINGLE-BARRELED ANCHORS

#12 SELF-DRILLING SCREW The 2-Seal TieTM Anchor meets or exceeds requirements of
INTEGRATED INTO BARREL FOR the Commonwealth of Massachusetts State
ATTACHMENT TO METAL STUD Building Code for air leakage and water penetration.
Contact H& B's technical department for test results.
Patents Pending

2 1
CONCRETE SEAL TIE
The Concrete Seal Tie accepts the 2-Seal Byna-Lok Wire Tie to
4
tie the masonry veneer to the substrate. The #14 diameter screw 3
portion has special alternating threads making it suitable for use with
concrete, CMU or brick backup, and is provided with a single EPDM
sealing washer. The special point affords easy installation into a pre-
drilled hole.

Barrel portion available in 5/8", 1", 1-1/2", 2", 2-1/2", 3" and 3-1/2"
lengths to accommodate insulation. Available Polymer Coated or
Type 304 Stainless Steel.

2-Seal Byna-Lok Wire Tie

Suitable for seismic zones with the simple addition of 9 ga. or


3/16" continuous wire into the track formed by the swaged, 1. STEEL STUD

overlapping legs. 2. RIGID WALLBOARD

Available 3/16" diameter x 3", 4" or 5" long, Hot Galvanized or 3. VAPOR BARRIER

Type 304 Stainless Steel. 4. RIGID INSULATION

Manufactured from a minimum of 95 %


recycled material.

Sold only in conjunction with 2-Seal TieTM or Concrete Seal TieTM.

Installation chuck adapter for both the 2-Seal TieTM and Concrete Seal TieTM sold separately.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 11
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Seismiclip Interlock System


SEISMICLIP 1
INTERLOCK SYSTEM 6
Reinforced masonry veneer wall applications 2
7
New masonry veneer can be anchored to existing masonry, concrete
or steel with the Seismiclip Interlock System. Engagement into the
Seismiclip is afforded by using one of H&Bs masonry wire ties and con- 3
tinuous wire in conjunction with standard H&B anchors as shown below.

Horizontal Joint Reinforcement Wire and Masonry Tie are snapped into 8
4
the Seismiclip and surrounded by mortar. This allows all components to
function integrally as a single unit. 9
5
The Seismiclip is an extrusion of durable, impact-resistant, rigid
P.V.C.. It features retaining ridges to ensure correct snap-in insertion
1. INSULATION
of Vee Byna-Tie and continuous wire with a multi-grooved base to
bond mortar. 2. CONTINUOUS JOINT REINFORCEMENT WIRE

3. SEISMICLIP
Seismiclip #187 - for use with 3/16 dia. Vee Byna-Tie
Seismiclip #250 - for use with 1/ 4 dia. Vee Byna-Tie 4. VEE BYNA-TIE
(Both versions can be used with either 9ga. or 3/16 dia. continuous wire.) 5. X-SEAL TAPE

Can. Pat. No. 1,313,887 6. RIGID WALLBOARD


U.S. Pat. No. 4,875,319 4 7. SELF-DRILL / SELF-TAP SCREW
3
2
1 8. STEEL STUD
SEISMICLIPS 1 2 3 4 9. X-SEAL ANCHOR (SEE PG. 10 )
#187 9GA 3/16 3/16 3/16
#250 9GA 3/16 1/4 1/4
Seismiclips are sold only in conjunction with
other compatible H&B products.

Various Anchor Applications

DW-10HS #345-BT #359FH #362 Gripstay Channel #305 Dovetail Slot


(w/ Vee-Byna Tie) (w/ Vee-Byna Tie) (w/ #363) (w/ #315)

Self-Drilling Self-Tapping Screw H&B Type 304 Stainless Steel Screw


Self-Drilling Self-Tapping
Standard Sizes: #10 or #12 x 1-1/2 - 5 long.
Optional pre-installed EPDM sealing washer available.
. Type 300 Series Stainless Steel shank for
Finishes: Zinc Plated
Polymer Coated
.. enduring corrosion protection.
Tough carbon steel point for easy drilling.
EPDM sealing washer pre-installed.
Type 410 Stainless Steel
Standard Sizes: #12 x 2 - 4 long.

IMPORTANT: All system testing was done with H&B components. We can not be held responsible for system performance if all
components are not manufactured by Hohmann & Barnard.

A 12 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Byna-Lok Wire Tie
New masonry veneer can be anchored to existing masonry, concrete or steel with the Byna-Lok Wire Tie.
Various H&B anchor systems can be fitted with the Byna-Lok Wire Tie, affording easy and secure insertion
of the continuous joint reinforcing wire. Masonry veneer walls are then reinforced in accordance with the
principles stated below. H&B recommends Stainless Steel for maximum corrosion protection.
U.S. Pats. 5,454,200 & 6,925,768 Other Patents Pending

Standard: 3/16" dia. X 3", 4", 5", 6, 7 or 9 long.


Finishes: Hot Dip Galvanized, Stainless Steel

Shown with X-SEAL Anchor


(see page 10 for further information).
1 Also compatible with DW-10 and DW-10HS .

. Swage and mild pitch on legs of the Byna-Lok Wire Tie provide an integral
track for the continuous joint reinforcement wire.
3 . Suitable for standard 3/8" mortar joint.
. More surface engagement of the continuous wire and the integral track than
2

. Reduces potential for incorrect placement or disengagement of the continuous


any other system on the market.
1. SWAGED TO ACCEPT CONTINUOUS WIRE

. Economical. Add continuous wire to masonry walls at


2. UPWARD PITCH FRONT LEG wire due to workmanship error.

3. UPWARD PITCH REAR LEG


little additional cost.

Why specify continuous joint reinforcement wire?


Enhanced Performance
The use of a continuous wire in masonry veneer walls is beneficial in providing additional
protection against problems arising from thermal expansion and contraction. It also allows
for a more uniform distribution of lateral forces.

Seismic Zone Conformance


This system conforms with requirements of the Uniform Building Code for seismic zones
[Sec.3006 (D)L (I) ]. The code requires anchored veneer walls to have a continuous wire embedded in the
mortar joint. This wire is to be secured to the tie anchor, which is fastened to the supporting structure.

Various Anchor Applications

#315-BL #363-BL #345-BL


Byna-Lok Byna-Lok Byna-Lok
Flexible Dovetail Flexible Gripstay Flexible Tie

#305 #362
Dovetail Slot Gripstay
Channel

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 13
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Seismic Veneer Anchors


#303 SV Seismic-Notch H&B Gripstay, Dovetail and L-Shaped Anchors can be
Dovetail Anchor modified to comply with seismic codes, which call for con-
tinuous wire in the veneer to be an integral component of
the anchor system. The Seismic Notch forms a seat to
accommodate 9 gauge or 3/16" diameter continuous wire.

#303 SV Standard - 1-1/4 wide x 14 ga. or 12 ga. thick with


a standard dovetail head. Made to order in any length.
#345 SV
Seismic-Notch
Veneer Anchor #345 SV Standard - Same availability as above with 9/32
diameter hole. Made to order in any length.

#364 SV Standard - Same availability as above with a


standard gripstay notch. Made to order in any length.

#364 SV Seismic-Notch T-Lok Tie - 14 ga. or 12 ga. thick. Backplate portion made
Gripstay Anchor to accommodate 0- 4 insulation thickness. Pintle portion
available in 3, 4 or 5 long. Other sizes available upon
request.

Configuration of masonry plate T-Head allows easy


insertion into slot, while preventing future disengagement.
T-Head also prevents tie from being installed beyond
allowable eccentricity.
T-Lok Tie U.S. Pat. No. 5,816,008

Finishes: Mill Galv


Hot Galv
Stainless Steel

The Channel-Tee Seismic-Notch Anchor System


Ideal for use where unlimited vertical adjustability is preferred. The Continuous
Channel is surface mounted to the back-up. The Seismic-Notch Anchor is then
easily inserted into the channel anywhere along the vertical length to conve-
niently fit wherever the mortar joint lies. Continuous joint reinforcing wire is
easily inserted into the seismic notches of each anchor.

. Thin 5/8" profile of channel is ideal for tight cavity

.
conditions. Channel provided in 10 lengths.

.
Holes drilled 12" on center in channel.
Seismic-Notch Anchor available 16 ga. thick by 3",

.
4" or 5" long.

.
Other sizes available upon request.
All components available Mill Galv, Hot Galv or Stainless Steel Also suitable for use
on concrete or CMU

A 14 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Wall Ties and Anchors
VB - Vee-Byna Tie VB - Vee Byna-Tie Standard - 3/16 or 1/4 diameter.
Lengths: 3, 3-1/2, 4, 4-1/2, 5, 6, 7 and 9.
Other sizes available upon request.
For use with H&Bs DW-10 Series Anchors, X-Seal Anchors
(tying brick veneer to steel studs), or #359 Series Weld-On
Ties (tying masonry walls to steel columns).
Finishes: Mill Galv, Hot Galv, Stainless Steel

#303 #303 Standard - 1 wide x 16 ga.,14 ga. or 12 ga. thick by


#305 3-1/2 or 5-1/2 long. Other lengths available upon request.
Corrugated Dovetail Dovetail Slot
Brick Tie #305 Standard - 1 wide back x 1 deep x 22 ga., 18 ga.
or 16 ga. thick by 10 long foam filled.

Finishes: Mill Galv


Hot Galv
Stainless Steel

#315 Standard - Dovetail end is 1 wide x 14 ga. thick.


Vee Byna-Tie portion is 3/16 diameter x 3, 3-1/2, 4,
#315
4-1/2, 5, 6, 7 or 9 long. Other sizes available upon
Flexible Dovetail
request.
Brick Tie
Vee Byna-Tie portion manufactured from 95 %

recycled material.

Finishes: Hot Galv or Stainless Steel

IMPORTANT: We are not responsible for incompatibility if ties or


slots are interchanged with those of other manufacturers.

#344 #344 - Made to order from 1-1/4 or 1-1/2 wide x 1/8 or


Rigid Partition 1/4 thick bar stock by any length. Standard bends are 2.
Anchor Other sizes available upon request.
Heavy duty carbon steel plate manufactured from 99 %

recycled material.
Stainless Steel recycled content see page 28.

Finishes: Plain Steel


Hot Galv
#345 Stainless Steel
Corrugated
Buck Anchor #345 Standard - 1-1/4 or 2 wide x 16 ga., 14 ga. or 12
ga. thick; 2-1/2 to 8-1/2 long. Bend is 1-1/2 long with
5/16 hole. Other sizes available upon request.

#345-BT Standard - Sheet steel is 3/4 wide x 12 ga.


thick with 5/16 hole. Vee Byna-Tie portion is 3/16
diameter x 3, 3-1/2, 4, 4-1/2, 5, 6 or 7 long. Other
#345-BT sizes available upon request.
Flexible Tie Vee Byna-Tie portion manufactured from 95 %

recycled material.

Finishes: Mill Galv


Hot Galv
Stainless Steel

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 15
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Wall Ties and Anchors


#301W Column
#301W - 3/16 or 1/4 diameter x 12 long. For use with
Web Tie
#359 Weld-On Tie (anchoring masonry to structural
column).

#302W - Same availability as above with a 1 flat


end for use with #359FH Weld-On Tie.

Standard Widths:
2-3/8 (for 4 block) 8 (for 10 block)
#302W Column
4 (for 6 block) 10 (for 12 block)
Web Tie
6 (for 8 block) 12 (for 14 block)

Finishes: Mill Galv


Hot Galv
Stainless Steel

#359 & #359-C #359 - 1/4 diameter x 8 long.


Weld-On Ties
#359-C - 1/4 diameter x 8 long with offsets 8 on
center.

#359FP - 3/8 diameter x 9 long. Exaggerated offset


dimension (specify when ordering).

#359FP-C - 3/8 diameter x 8 long with offsets 16 on


center. Optional backplate (sold separately) restrains
compressive loads.
#359FP &
#359FP-C Deep offset
For use when there is a requirement for spray-on
for use with
Weld-On Ties fire-proofing fireproofing. The exaggerated offset dimension allows
(Shown with
for projection beyond fireproofing for visibility and
optional backplate) accessibility to the mason.

#359FH - 3/4 wide x 12 ga. thick x 6 long (4 verti-


cal adjustability). 1/4 holes provided for attachment to
masonry.

For use with #302W Column Web Tie or Vee Byna-


#359FH
Tie. The systems anchor masonry to the structural
Weld-On Ties
frame, while allowing vertical differential movements
between steel and masonry.

Finishes: Mill Galv


Hot Galv
Stainless Steel

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

A 16 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Column and Beam Anchors
#351 #351 - 3, 5, 7 or 9 long. Other lengths available upon request.
Wire Column
Tie For anchoring masonry to structural column when masonry is
parallel to column flange.

#352 - 8, 10, 12 or 14 long. Other lengths available upon request.


For anchoring masonry to structural column when masonry is
perpendicular to column flange.
#352
Wire Column Standard: 3/16 or 1/4 diameter with 2 Bend and 2-1/2
Tie Hook with 1/2 opening.
Finishes: Mill Galv, Hot Galv or Stainless Steel

H&B manufactures steel wire products from a minimum of 95 %

recycled material.

#353 #353 Standard - 1-1/4 wide x 12ga. thick. Made to order


Column Anchor based on flange width and overall length. Other thicknesses
(including 1/4 heavy duty) available upon request.
For anchoring masonry to structural column when masonry is
perpendicular to column flange.

#353L Standard - Same as above. Made with a slotted hole


to accept Positive Lok Bolt to mechanically engage both sides
#353L of the flange.
Column
Anchor For anchoring masonry to the building frame while restraining
both positive and negative wind load actions.

#354 Standard - 1-1/2 wide x 12 ga. thick. Notch is 1 long,


beginning 1 from end. Made to order in any length. Other
notch sizes available on special order.
#354 For anchoring masonry to structural column when masonry is
Notched Column parallel to column flange.
Anchor
#355L Standard - 1-1/4 wide x 12 ga. thick. Other thick-
nesses (including 1/4 heavy duty) available upon request.
Made with a slotted hole to accept Positive Lok Rod.
For anchoring masonry to the building frame while restraining
#355L both positive and negative wind load actions.
Column Anchor
#357 Standard - 1-1/4 wide x 12 ga. thick. Other thickness-
es (including 1/4 heavy duty) available upon request. Made
to order in any length.
For anchoring masonry to structural beam when masonry is par-
allel to column flange.

#357 Finishes: Mill Galv, Hot Galv or Stainless Steel


Beam Anchor
Heavy duty plate for column & beam anchors is 99 %

recycled material.
Stainless Steel recycled content see page 28.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 17
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Gripstay Channels & Anchors


#360 & #361 Gripstay Channels #362-CX
Gripstay Channel System

#362 & #362-C Gripstay Channels

#360 - 7-1/2 long (5-1/2 vertical adjustability).

#361 - furnished with welded straps for embedment


into block back-up.

#362 - 6-1/4 long o.a., furnished with built-in end clips


for attachment to masonry.

(shown with optional Lok-Channel Clip) #362-C - 5 long, other lengths available in 7-1/2
increments.

Standard: 14 ga., 12 ga. or 11 ga. thick with 5/16 holes. #362-CX - 5 long, other lengths available in 7-1/2
increments. Made to order with welded legs to accom-
Finishes: Mill Galv modate any thickness insulation / wallboard.
Hot Galv
Stainless Steel U.S. Patent No. 5,063,722

#363 Flexible
Gripstay Anchor
. Gripstay Head fits any style H&B Gripstay Channel
(tying masonry to steel columns, concrete, or exist-
ing walls). Allows generous vertical adjustability
along slot of channel.

#363 Standard - Gripstay head is 14 ga. thick


x 1-1/4 wide. Vee Byna-Tie portion is 3/16 dia. x
3, 3-1/2, 4, 4-1/2, 5, 5-1/2, 6 or 7 long.
Other sizes available upon request.
#364 Corrugated
Gripstay Anchor Vee Byna-Tie portion manufactured from 95 %

recycled material.

#364 Standard - 16 ga., 14 ga. or 12 ga. thick


x 1-1/4 wide by 2-1/2 to 8-1/2 long.
Other sizes available upon request.

#365 #365 Standard - Same as above. Bend is 1 long.


Bent Gripstay Longer bends available upon request.
Anchor
Finishes: Mill Galv
Hot Galv
Stainless Steel

A 18 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Ties & Misc. Accessories
Spyra-Lox Spyra-Lox
Rebar SL 4/5 - # 4 or #5 rebars
Lap-Joint Tie SL 6/7 - #6 or #7 rebars
SL 8/9 - # 8 or #9 rebars (#9 is 1-1/8o.d. nominal, 1.27 actual)
SL 11 - #11 rebars (1-1/4 o.d. nominal, 1.41 actual)
No tools. Eliminates cumbersome procedure of tying lap-joined
rebars together in reinforced walls. Increases worker produc-
tivity. Reduces lifting-height of block over rebars. Flow through
design allows grout to uniformly encase rebars at overlap.
Finish: Mill Galv
RB & RB-Twin
Rebar Positioners
RB - 9 ga. dia. wire for 6, 8 or 12 block.
For positioning rebars in center of block. The z-shaped wire
bridges cell of block while bends rest on shell.
RB-Twin - Same as above with double loops to hold 4 rebars.
Finishes: Mill Galv, Hot Galv or Stainless Steel

H&B manufactures steel wire products from a minimum of 95 %


recycled material.
Stainless Steel recycled content see page 28.

Slip-Set Slip-Set Stabilizer


Stabilizer
Bonds masonry walls and restrains lateral movement while
allowing expansion and control joints to perform as designed.
Field Bend Field bend to connect intersecting walls, or new walls to exist-
ing walls.
Finishes: Mill Galv
Hot Galv
CWT Stainless Steel
Corrugated
Wall Tie CWT Standard - 22 ga., 18 ga., or 16 ga. thick x 7/8 wide x
7 long. Other sizes available upon request.
Finishes: Mill Galv
Hot Galv
Stainless Steel

MWT Mesh Wall Tie


MWT Standard - 1/2 square x 16 ga. thick x 100 rolls. Can
be cut to other lengths upon request.
For bonding intersecting masonry walls. Conforms to ASTM A 185.
Finishes: Hot Galv
Stainless Steel

MGS Mortar / MGS Standard - 1/4 square x 4, 6, 8, 10 or 12 wide x 100


Grout Screen rolls. Monofilament screen is fabricated from high strength,
non-corrosive polypropylene polymers.

Isolates flow of grout in designated areas requiring reinforced


concrete block. Also allows for greater bonding of masonry
anchor in hollow block construction.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 19
Section A - Masonry Systems

PTA Series Partition Top Anchors


PTA Series Partition Top Anchors
PTA Series Partition Top Anchors have been developed to provide lateral shear resistance at the upper limit of masonry walls. They
permit vertical deflection of the slab above, without transferring compressive loads to the masonry wall below. PTA Series Anchors
are suitable for construction using steel or concrete. PTA Tube with expansion filler is placed over rod anchor, which has been
attached to concrete or steel by any of the methods illustrated. The vertical joint is then filled with mortar, fully surrounding tube.

Other sizes available for heavy-duty applications. Contact H&Bs technical department.

PTA-364 PTA-420 PTA-422 PTA-RN


(no PTA Tube required)

Sizes: 12 ga. thick Sizes: 3/8 threaded rod


Finish: Mill Galv Sizes: 12 ga. strap with beveled nut
Hot Galv (5/16 dia. holes), 3/8 rod Finish: Mill Galv
Stainless Steel Finish: Mill Galv Sizes: 12 ga. thick
Hot Galv available for 4-12 block
Stainless Steel Finish: Mill Galv PTA-310
Hot Galv
Stainless Steel

Sizes: 3/8 rod,


12 ga. dovetail head
Finish: Mill Galv
All details shown
Hot Galv
with H&B
Neoprene Sponge Stainless Steel

Any H&B Gripstay Welded Bolted Welded Bolted H&B #305 H&B #305
Channel Connection Connection Connection Connection Dovetail Slot Dovetail Slot

Vertical Section Horizontal Section


Typical Masonry Wall
A B
A

PTA Tubes
Clear butyrate tubes with compressi-
ble polyethylene filler (for use with all
PTA series anchors except PTA-422)

A 20 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM

H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Control Joints . Weep Holes . Mortar Net

ard -8 ) -12 ) RS Series - Rubber Control Joint


nd ) e RS 7/8
ta Te
-S 5/8 RS- /8) (6 RS 1/8
S
R (2 5 (11 Extruded rubber material designed for masonry walls at control joints.
(2 Rubber material conforms to ASTM D 2000 2AA-805.

VS Series - PVC Control Joint


rd 8 The VS Series is a complete line of polyvinyl chloride control joints
n da S -67 8) 18 suitable for various wall conditions.
a
-St /8
) e
-Te ) V 7/ -11 8)
VS (2 5 VS 5/8 (6 VS 1 1/ PVC material conforms to ASTM D 2287 (Type PVC 654-4).
(2 (1

Manufactured from 50 %
recycled material.

#341 Round Plastic Weep Holes #341 Series Standard - 1/4 or 3/8" outside diameter x 4" long.
#342 Rectangular Plastic Weep Holes
#342 Series Standard - 3/8" wide x 1-1/2" high x 3-1/2" long.
#341W & #342W - Provided with cotton wick attached, for place-
ment inside cavity.
#341S & #342S - Provided with screen insert ( Brass or Stainless
Steel), to prevent infiltration of insects or debris.
#341W/S & #342W/S - Provided with both wick and screen.

#343 Louvered Weep Holes #343 Standard - 2-1/4, 2-7/8 or 3-1/2 high, injection-molded flexible PVC.
#343W WilcoTM Weep Holes Available only in Gray. Rectangular closer strip prevents mortar droppings from
clogging openings. Compressible flanges for joint widths of 1/2 - 3/4.

#343W Standard - 2-1/4 or 3-3/4 high, painted aluminum. Available in Gray


or White.
Manufactured from 100 %
post-industrial and /or post-consumer
recycled material.
Louvers direct passage of water from cavity to outside of building, while pre-
venting reverse passage of water. Design permits air passage into cavity, thus
aiding in pressure equalization while reducing suction.

QV Quadro-VentTM QV Standard: 3/8 x 3-3/8 x 2-1/2 high


Jumbo: 3/8 x 3-3/8 x 3-1/2 high
Other sizes available upon request.
Colors: Gray, Clear, Cocoa, Tan or Almond
Honeycomb design restricts ingress of insects and other debris. Allows pas-
sage of moisture up to its 2 1/2 height, important in the event of mortar drop-
pings at bottom of cavity. Also suitable for top of wall venting.

The Mortar Net The Mortar Net - .4, 1 or 2 thick x 10 high by 5 long.
Catches and permanently suspends mortar droppings in masonry
cavity walls so water always has open flow paths to the weeps. The
unique patented dovetail shape breaks up mortar droppings and
prevents mortar damming.

1 is manufactured from 35 %
2 is manufactured from 50 %

recycled material. recycled material.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 21
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems

Aluminum Brick Vents


Extruded Aluminum Manufactured from approximately 60 %
recycled material.

Features
. Minimum .125 6063-T5 alloy.
. Standard 204-RI clear anodized finish.*
. Overlapping blades, all at 45, with storm lip.

STYLE E
. Extruded stop for screen retention.
. Continuous weepage on bottom.
. Special custom sizes available.
.Lengths up to 8 ft. available without front mullions - continuous blade effect.
. Extruded vents can be readily made to any specified height or width
without exposed mullions.

1 1/2 Deep Nominal Sizes (see notes below)


4 Deep with 1 Flange WxH
E 825 F 825 8-1/8 x 2-3/8
E 847 F 847 8-1/8 x 4-3/4
E 808 F 808 8-1/8 x 7-3/4

STYLE F
E 125 F 125 12 x 4-3/4
E 128 F 128 12 x 7-3/4
E 1212 F 1212 12 x 11-3/4
E 157 F 157 15-5/8 x 7-3/4
E 1516 F 1516 15-5/8 x 15-3/4
E 162 F 162 16-1/2 x 2-3/8
E 164 F 164 16-1/2 x 4-3/4
E 168 F 168 16-1/2 x 7-3/4
E 1616 F 1616 16-1/2 x 15-3/4
E 244 F 244 24 x 4-3/4
E 248 F 248 24 x 7-3/4
E 3208 F 3208 32 x 7-3/4
E 4808 F 4808 48 x 7-3/4

Notes:
STYLE CA

E vents add 1/4 to nominal height for ribs.


F vents add 1 face flange on 4 sides to nominal size.
Add 1/4 to nominal width for mechanical fastener heads
*Non-standard finishes include medioum or dark bronze anodized,
kynar or baked enamel

Cast Aluminum
Nominal Sizes (see note below)
4 Deep WxH
Note: All extruded and cast vents can be
equipped with operable dampers & ducts
CA 825 8 x 2-1/4
CA 847 8-1/4 x 4-15/16
CA 808 8 x 7-7/8
Features
CA 123
CA 124
12 x 2-3/4
12 x 3-1/2 ..Minimum .125 thick ..Mill finish*
CA 125
CA 128
12 x 5
12 x 7-3/4 ..Rear water stop
One piece molded unit .Overlapping
Load bearing
blades
CA 162 16-1/2 x 2-3/8 Continuous bottom weepage
CA 1604 16 x 4
CA 164 16 x 4-15/16
Note:
CA 166 16 x 6
Cast aluminum vents are standard in mill finish and do not contain
CA 168 16 x 7-3/4
mortar ribs. *Also available in baked enamel at extra charge.

A 22 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Concrete Inserts

LW-340 HW-340 ASKEW HEAD BOLT


380-D

LW-340 & HW-340 Malleable Iron Wedge Inserts


Wedge inserts are embedded into concrete slabs. Nail holes in the back of the insert allow
easy nailing to forms. When the forms are stripped, the open face of the insert is flush with
the concrete. The beveled head of the askew head bolt engages the internal wedge shape
of the insert and produces an automatic tightening action when a load is placed on it.
Available Hot Dip Galvanized.

Note: LW-340 Long Wedge Insert is suitable for use at the bottom of the slab or when
additional vertical adjustability is needed. HW-340 Standard Wedge Insert must be installed
at least 1-1/2" from bottom of slab.

380-D Malleable Iron Adjustable Insert


The 380-D is a malleable iron insert with an integral track that allows 3" of adjustability. A
square nut is installed prior to nailing the insert to the formwork. When the forms are strip-
ped, the face of the insert is flush with the face of the concrete. The sliding nut can then
accept machine bolts or threaded rods for installation of precast panels, overhead piping or
mechanical conduits. (Overall depth of insert is 2-1/2.)
Available Plain or Hot Dip Galvanized.

Performance Data A B
Shear Tension Concrete Strength Torque

LW-340 17,305 lbs. 17,367 lbs. 4,125 psi 150 ft./lbs.


HW-340 16,650 lbs. 13,093 lbs. 4,125 psi 150 ft./lbs.

380-D 13,400 lbs. 7,112 lbs.

All values listed are ultimate capacities in pounds which should be reduced by a C
minimum safety factor of three to determine the allowable working loads. D

Askew Head Bolt E

F
5/8 or 3/4 dia. x 2, 2-1/2, 3 or 4 long.
Available Plain, Stainless Steel or Zinc Plated. Hot Galv available on special order.

Performance Data Bolt dia. A B C D E F


Carbon Steel 60,000 psi minimum Tensile Strength LW-340 3/4 2-3/8 1-3/16 5-1/2 3 3-1/2 7/8
Stainless Steel 70,000 psi minimum Tensile Strength HW-340 3/4 2-1/2 1-3/16 4 1-3/4 2 7/8

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 23
Section A - Masonry Systems

Sharktooth Inserts
Hohmann & Barnards Sharktooth Insert has various applications and is capable of developing working loads up to
8,000#/ft. in both shear and tension. It is adjustable along virtually its entire length, and also allows in and out adjustment, while still
resisting shear and tension loads. Inserts available in hot-dip galvanized or Type 304 Stainless Steel (Type 316 Stainless Steel also
available on special order). It is fabricated in lengths from 3" to 12'-0" long, and can be custom designed for project-specific appli-
cations, such as radiuses or specific lengths. The Sharktooth Insert is a new, labor-saving, pre-engineered, high-strength insert
from Hohmann & Barnard.

Features:
. Serrated shark-tooth design allows insert to resist high . Allows for substantial vertical adjustment along full length of insert.
vertical shear loads (eliminates potential for vertical slip
due to inadequate bolt torque, as with wedge style inserts). . Welded connections not required! Nut or bolt connection into
. Rebar interference not an issue (unlike post-installed insert allows for easy installation and adjustment.

expansion bolts). . Bolting hardware is U.S. standard thread (metric thread can be
. Additional rebar hairpins not required to develop published difficult to source).

. Custom design available for special load requirements.


working loads.

Various Sawtooth Insert Applications

Brick relief angle at concrete beam. Insert is cast into concrete walls to Cast into radial concrete to accept
Standard, economical application. accept stone anchors. Offers high handrails. Offers a high-strength,
Must maintain 1-1/2" of concrete strength connection on bridges, adjustable and bolted connection.
above and below insert. train tressels, or cubic stone appli- Eliminates field welding or post-
cations where weaker anchors are installed expansion bolts.
not acceptable.

A 24 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Sharktooth Inserts

Working Loads: Single Point Loading

Part # Insert Spacing Allowable Loads Ultimate Loads


Between
Length Studs Tension Shear Tension Shear
Working Loads: Multiple Point Loading
ST-3 3 n/a 5300# 5185# 10,600# 10,370#
Part # Insert Minimum Allowable Loads
ST-4 4 n/a 5300# 5185# 10,600# 10,370#
Spacing
ST-6 6 4 7889# 8059# 13,432# 20,147# Length Between
Tension Shear
Load
ST-8 8 5 7889# 8059# 13,432# 20,147#
ST-12 12 5 7889# 8059# 13,432# 20,147# ST-12 12 5 4525# 8059#
ST-24 24 5 7889# 8059# 13,432# 20,147# ST-24 24 5 4525# 8059#
ST-C 12-0 * 6 7889# 8059# 13,432# 20,147# ST-C 12-0 6 5300# 8059#

*ST-C standard length is 12 ft. Other lengths available on special order.

Performs as a gravity or tieback Insert is cast into underside of con- Cast into the underside of the con-
insert when cast into precast pan- crete slab so as to accept partition crete slab to accept pipes, duct-
els. Allows for a load-bearing, fully wall restraint angles. Offers ad- work, mechanical equipment, etc.
adjustable precast panel anchoring justable top of wall connection, As an adjustable mounting insert, it
system, while eliminating field weld- eliminating post-installed drilling eliminates post-installed anchors
ing. and potential of hitting rebar. that may hit rebar or tendons in
post-tensioned slabs.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 25
Section A - Masonry Systems

Repair & Restoration Anchors


Hohmann & Barnard carries a complete line of Repair & Restoration Anchors for masonry and stone veneers. Anchors are also avail-
able for conditions where installation from the interior is preferred.

Repair & Restoration Anchors may be required because of:


.. Buckling or cracking of facade due to building movements (inter-story drift, thermal movements, etc.)
. Failure of materials

. Corrosion of non-stainless steel ties


Absence of ties

. Refacing of existing structure with new veneer

#520RA
Epoxied rod/screen tube. Chemically
resecures veneer to concrete or
masonry backup.

Installation:
Drill hole and blow clean. Mixing nozzle dispenses epoxy into screen tube.
Insert tube into hole. When rod is inserted into tube, epoxy is displaced
through screen, filling any voids in the masonry structure. When cured,
epoxy forms an anchor connection that is capable of resisting positive and
negative loads.

Available in 1/4 - 3/4 diameters. Lengths as required. Rod and screen


tube furnished in Type 304 Stainless Steel.

#521RA-B
Expansion type. Mechanically resecures
veneer to concrete or masonry backup.
Supplied with pre-installed O-ring to
function as moisture drip.

Installation:
Drill hole through veneer into backup as required. With special 2-part tool,
expand inner shield, then outer shield. Fill hole with mortar.

Available 7, 8 & 9 long. Type 304 Stainless Steel rod with brass expan-
sion shields. Fits 1/2 diameter hole.

#522RA
Expansion/screw type. Mechanically
resecures veneer to wood or metal
stud backup. Supplied with pre-installed
O-ring to function as moisture drip.

Installation:
Drill hole through veneer. With special tool, install threaded portion of
anchor into wood stud, then expand outer shield into veneer. Fill hole with
mortar.

Available 7 long. Type 304 Stainless Steel. Fits 1/2 diameter hole in veneer.

A 26 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Helix Spiro-Ties
Helix Spiro-Ties are easily hammer-driven
into the substrate, where they tap a threaded
channel to produce a hold that is strong and
permanent. Available .276 (7mm) dia. x 6, 7, 8,
9, 10, 11 or 12 long. Other lengths available
upon request. Type 304 Stainless Steel.

. Secures masonry to brick, concrete,


CMU or wood
. Effectively resists tension while accom-
modating shear compression forces
. Has multiple drip points to prevent moisture
transfer across the cavity
. Allows for variations in joint coursing between wythes
. Type 304 Stainless Steel resists corrosion & degradation
Performance Data
Base Materials Embedment Tension (lbs.)

Concrete 2 541 lbs.


1
CMU (C-90 Block) 1-1/2 638 lbs.
Brick Veneer (Epoxied) 2 2730 lbs.

Installation Instructions Rotary/Percussion

1. A 3/16 dia. pilot hole is drilled through the masonry and


into the back-up material, to a predetermined depth, using a 2
rotary percussion drill (SDS type).
Note:
Rotary percussion drilling usually achieves the best results. SDS
hammer drilling may be required where masonry material is
extremely hard or dense. Percussion only

2. The Helix Spiro-Tie is loaded into the special installation tool


which is fitted to an electric hammer drill (SDS type). 3

3. With the drill set on percussion only, the tie is power driven into
position until the outer end of the tie is automatically recessed
into the face of the masonry by the installation tool.

4. The entry hole is finished over with matching materials.

H&B sources Stainless Steel from a wide variety


of vendors. Per the International Stainless Steel
Forum, Stainless Steel objects have an average of 60 %
recycled content.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 27
Section A - Masonry Systems

Stone Anchors and Accessories


H&B sources Stainless Steel from a wide variety of vendors.
Per the International Stainless Steel Forum, Stainless Steel objects have an average of 60 %
recycled content.

04 07 09 H 65 66
9- #3
#3 #3 #3 #3
0 #3

67 7-
H
02
R
#3 6 1 R
#4 05
#3 # 40 #4

#407
#406
08 4 2 4 25
#4 #4
1 2
42
3 2 #4
#4 # #4

28 1 2 3 34
#4 29 3 3 3 #4
#4 #4 #4
#4 ite
t
Ro

39
43
5 #4 41
# #4 2 44
#4
4
44
3 #4
#

0
1 X -1
0 2
45 #45 # 45 SR 1
# -1
X
SR
1 4 15 12
#5 #5 -
S RX
Channel Strut

3
Exp. Anchor

C-
Nail-In Type
Wedge Exp.

Sleeve Exp.

1 6
Embedded

X-
Concrete

SR
Screw
Bolt
Bolt

A 28 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section B - Flashing Systems

Flex-Flash Flashing
Moisture infiltration can occur at sills, projections, recesses, intersections and mortar joints.
The solution begins with proper flashing. H&Bs Flex-Flash is a 40-mil thick product for-
mulated with Elvaloy Kee*. It does not drool and combines the best features of other types
of flashing, making it a truly superior product.

. Extremely tough, with excellent impact and tear resistance


. Flexibility is maintained in all weather environments, even in extreme heat or cold
. Highly resistant to oils and repels most chemicals
. Not susceptible to UV degradation
. Compatible with most silicone and urethane sealants
. Suitable for thru-wall or surface-mount applications
. Pre-formed seamless corners and end dams available upon request.
Typical peel-and-stick flashings have a black, rubberized-asphalt
component that can drool or leach out of the building in warm temperatures if not pre-
cisely installed, leaving unsightly marks that are difficult to remove. Flex-Flash has a
pressure-sensitive, clear adhesive that will not drool when exposed to UV or heat.

Flex-Flash may be used in thru-wall or surface-mount applications. For surface-


mount applications, apply to clean, dry surface. For surfaces where additional adhe-
sion may be required, use H&B Foam-Tak Hi-Performance Spray Adhesive.
Termination Bars must also be used. Flex-Flash should be extended beyond the wall
face and cut flush with the brick. Optional Drip Plates may be used to effectively guide
moisture to the exterior. Surface-Mount

For maximum protection against moisture infiltration, specify the complete Flex-Flash
Flashing System, comprised of Flex-Flash, Mortar Net and H&Bs Foam-Tite
Seal Drip Plates and Termination Bar.

U.S. Pat. No. 6,584,746


Other Patents Pending

* Elvaloy is a registered trademark of the DuPont Company.


Thru-Wall

Sealant Compatibility Charts Company Product Primer Required


Urethanes

At various locations in a wall system the thru-wall flashing SIKA Sikaflex-1A #260-205
and a construction sealant are used together to form a
Sonneborn Sonolastic NP1 #733
weather-tight seal, i.e. relief angles, soft joints, door and win-
dow perimeters. H&Bs Flex-Flash has been tested for Tremco Dymonic #6 or #17
adhesion and compatibility by various sealant manufacturers
(see below). In all cases, the sealant manufacturers applica-
Company Product Primer Required
tion procedure should be followed and they recommend that
field adhesion testing should be continued throughout all Dow Corning 790 & 791 1200 Prime Coat
Silicones

stages of the project.


795 (Dark colors only) 1205 Prime Coat

NOTE: When using with insulation, please verify the com- GE Silicones Silpruf SS4179
patibility with the manufacturer. Pecora 890 & 895 P-120
Tremco Spectrem 2 #10

B2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Flex-Flash Accessories
H&Bs NEW Flex-Flash Drip Edge is a 45-mil thick product formulated with
Elvaloy Kee*. The durable, factory-formed extruded drip edge is fabricated 3 wide plus
3/8 drip. Compatible for use with any H&B flashing products.

. Available in colors to match mortar and/or brick (see list below). Special colors
. available upon request.

. Flexibility is maintained in all weather environments, even in extreme heat or cold


Extremely tough, with excellent impact and tear resistance

. Highly resistant to oils and repels most chemicals


. Compatible with most silicone and urethane sealants
. Not susceptible to UV degradation
Performance Data

Tear Strength - ASTM D-751, A


Machine Direction 100.44 (lbf)
Cross Machine Direction 87.10 (lbf)

Tear Strength at Break - ASTM D-751, A


Machine Direction 337.25 (lbf)
Cross Machine Direction 323.10 (lbf)

Elongation at Break - ASTM D-751, A


Machine Direction 34.49%
Cross Machine Direction 26.51%

Seam Strength - ASTM D-751 370.88 (lbf)


U.S. Pat. No. 6,584,746 Other Patents Pending
Puncture Resistance - ASTM D-751 73.22 (lbf)

Available colors: Heat Aging of Membrane


Break Strength at Break N/A
Red Ivory
Elongation at Break N/A
Tan Grey
Brown Dimensional Stability - ASTM D-1204 (for 6 hrs @ 176) N/A

Water Absorption - ASTM D-570 (for 48 hrs @ 70) N/A


* Elvaloy is a registered trademark of the DuPont Company.

Flex-Flash Pre-Molded Seamless Corners & End Dams


(for use with Flex-Flash & Copper-FlexTM Flashings only)

Simply place underneath our Flex-Flash Flashing for the ultimate protection against moisture penetration at corners and end dams.

4
4 4

4
4 4
4 4
4

Flex-Flash End Dam Flex-Flash Inside Corner Flex-Flash Outside Corner

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B3
Section B - Flashing Systems

Textroflash Flashing
H&B TextroflashTM Green
Thru-Wall Flashing / Surface-Mounted Flashing

Textroflash Green is a 40-mil thick composite membrane consisting


of a proprietary clear adhesive laminated to a polyethylene sheet. It is
adhesive-backed with removable release paper, and will not drool when
exposed to UV or heat.

Manufactured from 45 %
post-industrial and/or post-consumer
recycled material.

. Provides dual-layered waterproofing protection.


. Resists tearing and slicing.
. Laps easily, just press at overlap.
. Corners are easily formed on site.
. UV-resistant for up to 90 days.
Widths available: 12, 16, 18, 20, 24, 36, 48, 54,
60 & 72 wide x 50 long

Surface-Mount Thru-Wall Patents Pending

H&B NEW TextroflashTM


Thru-Wall Flashing / Surface-Mounted Flashing

Textroflash Flashing is a 40-mil thick composite membrane with a new, proprietary


adhesive that offers even more tackiness than the original Textroflash. This adhesive is fac-
tory-laminated to rugged, polyethylene sheeting, yielding a flexible membrane that is suit-
able for application to masonry, concrete, steel, gypsum and wood.
Patents Pending

. Adhesive-backed with removable release Thru-Wall


paper, will not drool when exposed to UV
or heat.
. Provides dual-layered waterproofing pro-
tection.
. Resists tearing and slicing.
. Corners easily formed on site. Laps eas-
ily, just press at overlap.
. UV-resistant for up to 90 days. Surface-Mount

Textroflash Flashing may be used in thru-wall or surface-mount


applications. A stainless steel H&B Drip Plate is required to effectively
guide moisture to the exterior. A stainless steel H&B Termination Bar must
also be used for surface-mount applications. Hohmann & Barnard is not
responsible for incompatibility resulting from the use of non-H&B products.

B4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H&B's NEW Flash-N-Drain multi-purpose membrane is the best combination
of ease-of-use and cost effectiveness for masonry cavity wall construction. This
unique product allows you to flash your walls and effectively drain the cavity with
the easy installation of the one product. Flash-N-Drain is comprised of a
dual-layered Elvaloy membrane, one side of which is ribbed in a continuous,
vertical zigzag pattern and covered with a fine mesh scrim.

Install Flash-N-Drain vertically onto the backup wall (as a thru-wall installa-
tion or fasten with H&B's Termination Bar), drape it across the cavity on a slight
downward incline, and cut flush with the face of the masonry wall. The scrim acts
as a bond-break so mortar will not clog the continuous vertical ribs of the
membrane. This allows any moisture entering the cavity (through wind-driven
rain, suction, condensation, etc.) to find its way into the channels created by the
vertical ribs and then out of the exterior wall.

Multi-purpose - reduces storage of


separate flashing and multiple thickness-
es of mortar suspension products

Labor saving - one process will flash


walls and prevent clogging of drainage
paths out of building

Unique Design - ribbed channels allow


egress of moisture to the exterior of the
building along the entire length of the
product, not only at weep holes

Water Drainage Performance Tests indicate water draining along the


full width of the flashing and through the weep holes.
Section B - Flashing Systems

Flashings
H&B Copper-TuffTM Copper Thru-Wall Flashing
Copper-Tuff s patented super-strong polymer coating is bonded to a 2 oz. copper
sheet for maximum performance at an economical price. A fiberglass scrim is embed-
ded between this coating and copper for excellent puncture and tear resistance.

. 2 oz. has more than twice the tensile strength of typical 5 oz. copper fabric flashing.
. Compatible with ACQ and all other treatments for pressure-treated lumber.
. Lightweight and flexible; easily conforms to any surface.
Also available with 3, 5, or 7 oz. copper sheet
Widths available: 12, 16, 18, 20, 24 & 36 wide x 25 long

C-TUFF TYPICAL NON-ASPHALTIC


FABRIC FLASHINGS
ASTM Brand A Brand B
Reference Test 2 oz. 3 oz. 5 oz. 3 oz. 5 oz.

ASTM D 412C Tensile Strength 137,000 psi 59,000 33,700 44,300 36,300
Elongation 3% 2% 4% 2% 2%
ASTM D 1004 Graves Tear
MD 23.3 lbf. 34.7 38.1 28.4 48.0
ff !
is Ruff-n-Tu
T his stuff
(at max. load) 0.05 0.05 0.04 0.06 0.06
TD 41.1 lbf. 38.0 40.1 26.7 47.2
(at max. load) 0.05 0.05 0.05 0.05 0.06
Asphalt-free composition compatible
ASTM D 1938 Tear Propagation
(Trouser Tear)
with a wide variety of sealants.
MD 4.3 lbf. 2.5 5.4 3.1 4.6 Approved Sealants
TD 5.2 lbf. 5.0 6.2 5.2 8.6
Dow Corning 756 SMS Building Sealant
ASTM E 154 Puncture Resistance
Dow Corning 791 Silicone Weather-
max. load deflection at 255 lbf. 215 387 219 422
max. load 0.56 0.68 0.73 0.49 0.99 proofing Sealant
failure type rupture rupture rupture rupture rupture
U.S. Pat. No. 6,928,780
Other Patents Pending

H&B Copper-FlexTM
Copper-FlexTM is a composite membrane consisting of a polyethylene film lami-
nated to a 2 oz. copper sheet to create a superior flashing that can also serve as
a drip edge. It has a pressure-sensitive, clear adhesive that will not drool when
exposed to UV or heat.
Also available with 3, 5, or 7 oz. copper sheet
Widths available: 12, 16, 18, 20, 24 & 36 wide x 25 long

. Extremely tough, with excellent impact and tear


. resistance
Maintains flexibility in extreme heat or cold

. weather environments

. Suitable for thru-wall or surface-mount usage


Highly resistant to oils and will repel most chemicals

. UV-resistant for up to 180 days.


. Asphalt-free composition compatible with a wide
variety of sealants
U.S. Pat. No. 6,945,000
Thru-Wall Surface-Mount
Other Patents Pending

B6 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Flashings

H&B Epra-MaxTM EPDM Thru-Wall Flashing


EPDM is a synthetic rubber that has been used extensively for decades in
the roofing industry. Its durability under harsh, exposed roofing conditions
renders it an ideal choice for use in more controlled applications, such as
thru-wall flashing. Epra-Max remains flexible down to -49 F, making it an
excellent product for year-round installation. No special contact adhesives
are needed when using Epra-Max Adhesive Tape for seams, corners or end
dams. For adhesion to various substrates, use the Adhesive Tape in con-
junction with Epra-Max Spray Primer, or use H&Bs Termination Bars.
Optional bonding adhesive is also available. Drip Plates are recommended
to guide moisture to the building exterior.

. Excellent elongation performance, tear and puncture resistance.


. Not susceptible to decomposition due to UV or ozone exposure.
. High or low temperatures are not detrimental to EPDM performance.
40 mil thick x standard widths of 12, 16, 18, 20, 24 or 36

H&B C-FabTM Flashing


Copper Thru-Wall Flashing

C-Fab Flashing is a sheet of soft-tempered copper that is permanently coated and


bonded between two layers of asphalt-saturated glass fabric. The asphalt -saturated
glass fabric adds protection to the copper during shipment, and also adds another
layer of waterproofing and chemical resistance. The coarse texture aids in the bond-
ing with mortar.

C-Kraft Duplex uses the same sheet copper, but the end product is lighter weight
and slightly less expensive, due to the use of kraft paper in lieu of glass fabric. The
kraft paper is also asphalt-bonded to the copper on both sides.

Copper sheet used in the fabrication of copper laminates conforms to


ASTM B 370 (110 Alloy).

H&B C-KraftTM Duplex Flashing


Copper Thru-Wall Flashing
Products are available in 3, 5 or 7 oz. weight.
Widths available: 12, 16, 18, 20, 24, 32 and 36

H&Bs Asphalt Mastic


H&Bs Asphalt Mastic is a high-grade, asphalt-based cement used
to bond asphalt-coated flashing to construction surfaces. It provides a
strong, flexible waterproof barrier with excellent adhesion. Asphalt
Mastic allows for expansion or contraction caused by temperature fluc-
tuations or building movement. It is furnished in 5 gallon pails.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B7
Section B - Flashing Systems

Metal Flashings
Section B - Flashing Systems

H&B manufactures a variety of metal flashing products and accessories to suit numerous job conditions. Products include standard
sheet flashings bent to custom sizes and shapes, pre-fabricated inside or outside corners, end dams, splice tape and reglets. Seen
below are various product styles, each of which are manufactured per the dimensional requirements of the customer. Metal flash-
ing products are manufactured from 26 ga. type 304 stainless steel and 16 or 12 oz. copper. (Lead-coated copper, terne-coated
stainless steel or other gauges are available on special order.)

MFL Metal Flashings STF Sawtooth Flashings

Thru-Wall Parapet / Coping

MFL can be formed STF acts to bond in all


according to job require- directions. Can be manu-
ments. State dimensions factured for parapet/coping
when ordering. Comes applications, or bent for
standard with factory- relief angle applications.
formed, hemmed drip State dimensions when
edge. ordering.

Surface-Mount At Relief Angle

H&B sources Stainless Steel from a wide variety of vendors.


Per the International Stainless Steel Forum, Stainless Steel objects have an average of 60 %
recycled content.

MFL Outside & Inside Corners


Metal Flashing Outside and Inside Corners are
custom-fabricated, pre-formed pieces with a smooth,
hemmed drip edge. Outside corners have a continuous,
uninterrupted drip edge for a smooth, non-jagged finish
(important in maintaining the integrity, aesthetics and
safety aspects of the flashing corner).
Compatible with ST Splice Tape. MFL - Outside Corner MFL - Inside Corner

Outside Corner (Thru-Wall) Inside Corner (Thru-Wall) Outside Corner (Surface-Mount) Inside Corner (Surface-Mount)

B8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Drip Plates
DP Our Standard Drip Plate, furnished with a smooth, factory-formed hemmed
edge for installation safety and uniform appearance. Fabricated from Type 304
or Type 316 Stainless Steel. Also available in copper and lead-coated cop-
per. Standard DP Drip Plates are compatible with all H&B flashing products.
DP-LB Same as above, for lip brick conditions.

FTS Optional Foam-Tite Seal TM offers unique added protection against


the ingress of water in cavity wall construction. It is a continuous 1/8
strip of factory-installed compressible foam to act as a bond-break and
help prevent air and moisture infiltration.
FTS-LB Same as above, for lip brick conditions.

FTSA Adds our optional Flash-AdhereTM Adhesive Strip* to the FTS Drip
Plate (as described above). This adhesive strip (with tear-off release
Available 1-1/2 or 3 wide (other widths paper) is factory-installed on the top side of the drip plate to aid in the
available on request). precise and permanent placement of the flashing.

U.S. Pat. No. 6,584,746 FTSA-LB Same as above, for lip brick conditions.
Other Patents Pending For corner pieces, reference inside or outside with above product numbers.

* Flash-AdhereTM Adhesive Strip is ONLY suitable for use with Flex-Flash or Copper-FlexTM Flashings.

Flex-FlashTM Flashing
Standard Brick
Flash-AdhereTM Strip
FTSA
Drip Plate
Foam-Tite SealTM

Sealant Relief Angle

Backer Rod Neoprene Sponge

Lip Brick Style

H&B sources Stainless Steel from a wide variety


of vendors. Per the International Stainless Steel
Forum, Stainless Steel objects have an average of 60 %
recycled content.
Drip Plate Corners
Drip Plate Inside and Outside Corners are pre-formed pieces with a smooth,
uninterrupted, hemmed drip edge to maintain the integrity of the flashing system.
Available with Foam-Tite SealTM and /or Flash-AdhereTM Adhesive strip*.

Outside Lip Brick Style Inside Corner

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B9
Section B - Flashing Systems

Reglets & Termination Bars

Concrete Reglet
Attaches easily to form for poured concrete conditions.

.. 3/4 deep x 8 lengths.

. Made of rigid PVC.


Built-in face piece keeps mortar out, yet easily tears off
prior to installation of flashing.

Masonry Reglet
Embedded in mortar joint of masonry backup to accept flashing.

.. Fits into 3/8 mortar joint.

.. 8 lengths.
5/8 internal depth, 1-1/4 o.a. depth.

. Made of rigid PVC.


Built-in face piece keeps mortar out, yet easily tears off
prior to installation of flashing.

Termination Bars
Termination Bars are fabricated from type 304 stainless steel, with 1/4 holes spaced 8 on center. They are compatible
with all H&B membrane and copper-laminate flashings. Available in two styles, Type T1 and T2. Both styles are avail-
able with optional Foam-Tite SealTM to aid in inhibiting moisture infiltration. This factory-installed foam strip helps
seal small voids occuring between the termination bar and any irregular surfaces of the substrate, while
offering added protection against water penetration due to deterioration of the sealant.

U.S. Pats. No. 6,945,000


Patents Pending

Sealant

Term Bar : Type T1


T1- 1/8 x 1 x 8 long Type T2
T2- 26 ga. x 1-1/2x 8 long
has a 3/8 flange
FTS - Foam-Tite SealTM : on top for easy
specify T1-FTS or T2-FTS caulking
when ordering.
Flashing

H&B sources Stainless Steel from a wide variety of vendors.


Per the International Stainless Steel Forum, Stainless Steel objects have an average of 60 %
recycled content.

Splice Tape
Splice Tape is a 4 wide x 50 ft. roll of H&B Flex-Flash.
It is adhesive-backed, reinforced for strength and easily
cut to required lengths on site. Suitable for thru-wall or
surface-mount applications.

U.S. Pat. No. 6,584,746


Other Patents Pending

B10 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section C - Residential

Window Products
Wrap-N-SealTM Self-Adhering Window Wrap & Expansion Joint

The Newest Way to Insulate . Our patented foam-flex process allows


& Seal-Out Air and Moisture optimal foam compression to maximize
Around Windows... sealing properties. Renders window
flanges impervious to air and moisture.
. Foam forms a continuous seal around
perimeter of flange and internally
between frame and rough opening for
Wrap-N-Seal protection.
. UV-resistant foam will not deteriorate
like typical thin films found on black
rubberized-asphalt tapes.
. Clear adhesive will not drool or stain
like typical black rubberized-asphalt
adhesives.

Patents Pending
. Specially formulated adhesive seals
around screws, nails and staples.

Stretch-N-SealTM Window Pan Flashing


H&Bs Stretch-N-SealTM is a stretchable flashing tape make with an elastic
nonwoven polyolefin membrane and adhesive. It is wrapped into the window
pan opening before the window is installed, flashing the bottom corners at the
window sill.
Available in 7 of 9 wide x 50 ft. long rolls

Manufactured from 45 %
post-industrial and/or post-consumer
recycled material. Patents Pending

Top-Seal TapeTM Over-Flange Tape

Patents
Pending

Manufactured from 45
%
post-industrial and/or post-consumer

. Self-sealing: seals around fasteners recycled material.

. Adhesive-backed with removable release paper . Durable: will not rot, crack or drool like typical rubberized-
. Ease of installation: apply to clean, dry surface
. Resists tearing and slicing . 40 mil thickness, 4 x 50 ft. long rolls
asphalt adhesives

. Laps easily, just press at overlap


. UV resistant up to six months For maximum weatherproofing, use in conjunction with
H&Bs Wrap-N-Seal window wrap.

C2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Roofing Products
Trac-SealTM Manufactured from 45 %
post-industrial and/or post-consumer
Self-Adhering Roofing Underlayment recycled material.

. 40 mil thickness, 36 x 66 ft. long rolls


. Adhesive-backed with removable release paper
. Provides dual-layered waterproofing protection
. Resists tearing and slicing
. Laps easily, just press at overlap
. Specially treated non-slip tracks for worker safety
. Self-sealing: seals around fasteners
. 120-day UV exposure
. Can be installed in temperatures at or above 25 F
. Durable: will not rot, crack or drool like typical rubberized-asphalt adhesives Patents Pending

Roofing Underlayment
H&B Roofing Underlayment is a polypropylene fabric with an anti-skid
coating. Unlike smooth-surfaced underlayments, the anti-slip walking
surface allows for steep-slope walkability. It is both lighter and stronger
than 30# felt.

H&B Roofing Underlayment is engineered to perform over a wider oper-


ating temperature range compared to asphalt felt.
Patents Pending . High Temperatures - Felts are prone to drying and cracking, and can
leach out oils, which may result in an oily, slippery surface. H&B
Roofing Underlayment is 100% asphalt-free and not subject to any
component leaching or loss of volatiles over time.
. Low Temperatures - Felts have a tendency to become very rigid, stiff
and brittle, and very difficult to roll out. Because asphalt felts contain
paper, they are also prone to absorb water, become heavier, and freeze
in cold weather, making the stiffness and unrolling problems even more
pronounced. H&B Roofing Underlayment is 100% synthetic, high-
strength, flexible engineered polymer that does not dry or crack under
either low or elevated temperatures.

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM C3
Section C - Residential

Termite Shields

Mite OutTM Eco-Friendly alternative to using


chemical pesticide treatments.
Copper Termite Shield with Sill-Seal

H&B Mite-OutTM Copper Termite Shield with sill-seal is


a sheet of soft-tempered copper that is permanently
1
coated on one side with a polyethylene membrane and
Copper
Foam Sill Seal. Copper flashing has long been used in Termite Shield
masonry construction due to its pliability and non-reaction Flashing
to any alkalais or acids that may be found in mortar. 2
Foam Sill-Seal
adhered to
Termite Shield
Copper Termite Shield Patents Pending
H&B Copper Termite Shield is a sheet of soft-tempered
copper that is permanently coated on one side with a
polyethylene membrane.

Copper
Termite Shield
Flashing
3
Tear-Away
Strip protects
2 copper during
installation

. Available in 8, 10 & 12 wide x 50 long rolls.


. Compatible with ACQ and all other treatments for
pressure-treated lumber.
. Asphalt-free adhesive will not stain concrete, vinyl
or wood.
. Compatible with all adhesives, caulks and sealants.
. Lightweight, flexible and easy to work with.
Conforms to any surface.

Sill-Seal
H&B Sill-Seal is a flexible, non-cross-linked polyethylene strip primarily used to
reduce air infiltration between the concrete foundation and sill plate. It works by
compressing to seal the gaps between the foundation wall and sill plate. Foam

. Closed-cell polyethylene foam wont fall apart on the jobsite or after


Sill-Seal

. Provides excellent resistance to water and water vapor.


years of use.

. Easy to install and does not irritate like fiberglass.


. Seals out most insects.

C4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section D - Air Barrier Systems

Commercial Air Barrier

H&B Commercial Air Barrier is an air and moisture barrier formulated from non-perforated, high-quality, non-
woven polyolefin. The sheet barrier is vapor permeable, yet helps prevent airflow and the passage of water. It
enhances the building envelope with a number of features in a functional, lightweight, easily installed membrane.

This weather barrier performs better than building paper or felt, protecting sheathing from moisture & wind-driven rain
Since it is non-absorbant it stays flat and tear-resistant. H&B Commercial Air Barrier allows the passage of vapor
(vapor permeable) to the outside of the building it, thus deterring mold & rot.

Ease of Installation -
extremely pliable material, for simple and easy forming
of corners.

Lightweight -
enables worker to handle and install rapidly.

Minimizes seams -
available in large format 5 ft or 10 ft wide rolls, reducing
overlaps and seams, thus reducing labor and material
costs.

Test Method Properties

Composition Non-perforated, high-quality,


nonwoven polyolefin
Thickness 0.009
Trapezoid Tear
ASTM D 117 15 lbs / 17 lbs
Tensile Strength
ASTM D 828 MD/CD 30 lbs / 32 lbs
Water Vapor Transmission
ASTM E 96A 28 perms
Air Porosity
TAPPI T-460 > 1500 seconds
Flame Spread H&B Commercial Air Barrier resists:
ASTM E 84 Class A . Wind
Water Resistance . Water
ASTM D 779 Pass . Tearing & Puncturing
Water Resistance
AATCC127 > 186 cm
. UV exposure for up to 4 months
AATCC127 using Textest Model FX 3000 > 275 cm Available in 5 ft or 10 ft wide x 150 ft
Air Permeance long rolls.
ASTM E 2178-03 < 0.001 L / s / m2
Basis Weight (gsm / oz / yd2) 82 gsm / 2.43 oz / yd2
CFCs used in production none
UV Exposure Rating 120 days

D2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Residential Air Barrier

H&B Residential Air Barrier is an air and moisture barrier formulated from non-perforated, high-quality, nonwoven
polyolefin. The sheet barrier is vapor permeable, yet helps prevent airflow and the passage of water. It enhances the
building envelope with a number of features in a functional, lightweight membrane. It is puncture and tear resistant and
supports UV exposure for up to 4 months.

This weather barrier is acceptable for applications up to four stories. For applications beyond four stories, or where a com-
mercial warranty is required, H&B Commercial Air Barrier is recommended. Residential air barrier is specifically for above
grade, vertical wall surfaces.

H&B Residential Air Barrier is acceptable for use behind:

. Traditional brick veneer


. Vinyl siding
. Wood siding
H&B Residential Air Barrier is suitable for application to:
. Exterior gypsum sheathing
. Exterior plywood sheathing
. Oriented strand board (OSB) sheathing
. Masonry

Test Method Properties

Composition Non-perforated, high-quality,


nonwoven polyolefin
Thickness 0.009
Trapezoid Tear
ASTM D 117 15 lbs / 17 lbs
Tensile Strength
ASTM D 828 MD/CD 30 lbs / 32 lbs
Water Vapor Transmission
Vapor-permeable, yet helps prevent
ASTM E 96A 56 perms
the passage of water and airflow
Air Porosity
TAPPI T-460 > 1000 seconds
Flame Spread
ASTM E 84 Class A
Water Resistance
ASTM D 779 Pass
Water Resistance
AATCC127 > 186 cm
AATCC127 using Textest Model FX 3000 > 220 cm
Air Permeance
ASTM E 2178-03 < 0.001 L / s / m2
Acceptable for use behind traditional
Basis Weight (gsm / oz / yd2) 72 gsm / 2.12 oz / yd2 brick veneer, vinyl and wood siding
CFCs used in production none applications
UV Exposure Rating 120 days

For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM D3
Hohmann & Barnards Textroflash Liquid
is an excellent air & vapor barrier and also performs as a
moisture barrier. It allows proper drainage in various types of
wall systems and provides protection from the detrimental Why use Textroflash Liquid?
effects of air exfiltration :. VOC-Free* (complete regulation compliance) &
and infiltration, such as HAPs-Free* (other brands contain up to 30%
energy loss, condensa- hazardous chemicals, which can leach into soil
tion, efflorescence, bac- and groundwater around buildings; Textroflash
terial growth, mold, etc. Liquid is especially suitable for schools)
More environmentally
friendly than other :. User-friendly - ready to use (no lengthy training,
spray-applied products, as with products requiring on-site mixing)

Textroflash Liquid is suitable for application to concrete, :. Reduces labor -


CMU, cast-in-place concrete or gypsum sheathing. It can be application rate
spray-applied or brush / roller-applied. Now also available in is just 40 dry mils
trowel grade. After curing (4-24 hrs. depending on ambient (other brands can
temperatures), Textroflash Liquid is a resilient, seamless mem- require up to 100
brane with high elongation and water-resistant properties. dry mils and mul-
tiple coats)
A Greener Solution
:. UV exposure up to 145 days (other brands aver-
When properly installed, Textroflash Liquid reduces energy age 75 days, when re-application may be required)
usage, thus reducing fossil fuel consumption (which can
contribute to the green-house effect). Its usage may con-
tribute toward achievement of LEED standards for
Optimizing Energy Performance.

* Volatile Organic Compounds are converted into ground level ozone when combining with the nitrogen
oxides from sunlight. Ground level ozone has been found to be a public health hazard. VOCs can also
pollute soil and groundwater if accidentally released from various industrial products. Hazardous Air Pollutants
are pollutants that may cause cancer or other serious health effects and have adverse environmental and ecological
effects. Both are coming under stricter limits and regulations in various states.
PRODUCT DATA
COMPOSITION:
WATERPROOFING
Asphalt CAS 8052-42-4
TEXTROFLASH LIQUID MODIFIED EMULSION
Water CAS 7732-18-5
COATING SPRAY & BRUSH GRADE FORMULA
Polymers CAS Mixture
PRODUCT DESCRIPTION: H&Bs TEXTROFLASH LIQUID Modified Clay CAS 14808-60-7
Emulsion Coating is a latex-modified asphalt emulsion and is 100% Pigment Disperser CAS Mixture
ASBESTOS-FREE. This material is an asphalt emulsion with poly-
mers and specialty additives to formulate a waterproof coating. LIMITATIONS: DO NOT ALLOW material to freeze. DO NOT THIN mate-
rial. DO NOT heat product over 160F as this can damage material.
BASIC USES: H&Bs TEXTROFLASH LIQUID Modified Emulsion
Coating is used as a protective coating for a variety of applications STORAGE: H&Bs TEXTROFLASH LIQUID Modified Emulsion
on asphalt, metal, masonry, and foam surfaces. Coating must be kept from freezing.

The following equipment is recommended for spraying: APPLICATION: H&Bs TEXTROFLASH LIQUID Modified Emulsion
Coating must be applied to a surface that is free from all foreign
Pump GH 833 PSI 1700-1850 PSI matter. This material should remain dry until it has cured. This
Spray Gun BLUE TEXTURE Spray Tip GHD 661 material can be applied by brush, squeegee, or spray equipment
Filters Remove any and should yield a coverage rate of 1 gallon per 25 square feet
internal filters from pumping system for non-vapor-permeable. (40 mils)

ABOVE GRADE - TESTING REPORT BELOW GRADE - TESTING REPORT


For Accreditation by: ABAA Version 1.1 For Accreditation by: ICC AC-29
Sample ID: TEXTROFLASH LIQUID Modified Asphalt Coating Sample ID: TEXTROFLASH LIQUID
Report # EXIOL6A Report # ESR-1490
Project ID: EXIOL6A Project ID: TX03L5A

1.0 Air Permeance Evaluation (ASTM E 2178) 1.0 Hydrostatic Pressure over Cracks (ASTM C 1306)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating achieves Result: H&B TEXTROFLASH LIQUID achieves a pass value of 3.75 psi
an air leakage rate of 0.00159 L/s/m2 at 75 Pa in the rapid test and a pass value of 2.5 psi in the long term test.
2.0 Water Vapor Permeance (ASTM E 96)
2.0 Low-Temperature Flexibility and Crack Bridging (ASTM C 836,
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
Section 6.7)
a 0.1 Perm rating
Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
3.0 Elongation & Tensile Strength (ASTM D 412-98a (2002) el) AC-29, Table 1 (ASTM C 836, Section 6.7) for Low Temperature
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages Flexibility and Crack Bridging. No Cracking or loss of adhesion.
41.3 psi tensile strength and 969.01% elongation
3.0 Adhesion Strength to Poured Cement (ASTM C836, Section
4.0 Water Absorption (ASTM D 570-98) 6.10)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 4.63% Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
water absorption 13.239 lbf/in. adhesion strength to poured cement
5.0 Adhesion Strength to Poured Cement (ASTM D903-98) 3.1 Adhesion Strength to Masonry (ASTM C836, Section 6.10)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating aver-
13.239 lbf/in. adhesion strength to poured cement ages 12.092 Lbf/in. adhesion strength to masonry
5.1 Adhesion Strength to Masonry (ASTM D903-98)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 4.0 Resistance to Water (ASTM D 2939, Section 15)
12.092 Lbf/in. adhesion strength to masonry Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
AC-29, Table 1 (ASTM D2939, Section 15) for Resistance to Water. No
6.0 Proportion of Solids (ASTM D 2697-86 (1998)) Blistering or Re-emulsification
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
65.62% solids 5.0 Remain in place during application (ASTM C 836, Section 6.9)
Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
7.0 Volatile Content (ASTM D 3960) AC-29, Table 1 (ASTM D2939, Section 15) for the ability to remain in
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages place during application. The final thickness after 24 hours was 0.0162
0.52% volatile content in.
8.0 Nail Sealability (ASTM D 1970)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating shows no 6.0 Water Vapor Permeance (ASTM E 96)
leaks when tested in accordance with ASTM D 1970 Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating aver-
ages a 0.1 Perm rating
9.0 Pull Adhesion to Poured Cement (ASTM D 4541)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 77.2 7.0 Extensibility after Heat Aging (ASTM C 836, Section 6.12)
psi pull adhesion Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
AC-29, Table 1 (ASTM C836, Section 6.12) for Extensibility after Heat
9.1 Pull Adhesion to Masonry (ASTM D 4541) Aging. Pass 1/4 inch stretch with no cracking
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
106.0 psi pull adhesion Conclusion: H&B TEXTROFLASH LIQUID passes the requirements of
ICC AC-29 Table 1 for the acceptance criteria of a cold, liquid-applied,
Conclusion: H&B TEXTROFLASH LIQUID Modified Emulsion Coating has
below grade, exterior damp proofing or Waterproofing material.
completed the testing required in ABAA Material Evaluation Process for Air
Barrier Materials, Components & Assemblies February 2006 Version 1.1.
Hohmann & Barnards TextroflashTM Liquid VP is a vapor
permeable air barrier. The breathable barrier allows proper
A Greener Solution
drainage in various types of wall systems and promotes dry-
ing of the wall cavity in either direction. It provides protection When properly installed, Textroflash Liquid VP
from the effects of energy loss, condensation, efflorescence, reduces energy usage, thus reducing fossil fuel
bacterial growth and mold. More environmentally friendly than consumption
other spray-applied products, Textroflash Liquid VP is suit- (which can con-
able for application to concrete, CMU, cast-in-place concrete tribute to the
or gypsum sheathing. It can be spray-applied or brush/roller- green house
applied. After curing, Textroflash Liquid VP is a resilient, effect). Its usage
seamless membrane with water-resistant properties. may contribute
to achievement
of LEED stan-
dards for Optimizing Energy Performance.

Why use TextroflashTM Liquid VP?


VOC-Free* & HAPs-Free* (other brands contain up to
30% hazardous chemicals, which can leach into soil and
ground-water; TextroflashTM Liquid VP is especially suit-
able for schools)
climate zone 2 User-friendly: ready to use (no lengthy training, as with
climate zone 3 products requiring on-site mixing)
climate zone 4
Reduces labor: application rate is just 20 dry mils (others
may require up to 100 dry mils and multiple coats)
The indicated line of demarcation separating the country is
UV exposure up to 120 days (other brands average 60
based on the International Building Code guidelines. Currently
days, when re-application may be required)
the use of a vapor barrier in climate zones 1-4 is common, yet
not mandated. The closer the proximity to the demarcation
line, the more discretionary the usage.

* Volatile Organic Compounds are converted into ground level ozone when combining with the nitrogen
oxides from sunlight. Ground level ozone has been found to be a public health hazard. VOCs can also
pollute soil and groundwater if accidentally released from various industrial products. Hazardous Air Pollutants
are pollutants that may cause cancer or other serious health effects and have adverse environmental and ecological
effects. Both are coming under stricter limits and regulations in various states.
PRODUCT DATA
Textroflash Liquid VP
Emulsified Non-Fibred Asphalt Coating

PRODUCT DESCRIPTION: Textroflash Liquid VP meets ASTM-D- in the foundation wall must be filled with non-shrinking grout or
1227-87 Type III specifications. This material is an asphalt emul- an asphalt-based mastic. Where non-shrinking grout is used for
sion with selected colloids to formulate a dampproofing coating. filling voids, the grout must be allowed to cure before the mem-
brane is applied. Concrete and parged masonry surfaces must be
BASIC USES: Textroflash Liquid VP is used as protective coating for cured and dry prior to application of the liquid air barrier mem-
a variety of applications on asphalt, metal, and masonry surfaces. brane.

COMPOSITION: APPLICATION TEMPERATURE: The air temperature for applica-


Asphalt CAS 8052-42-4 tion of TEXTROFLASH LIQUID VP can be as low as 26F; how-
Water CAS 7732-18-5 ever, the product must not be allowed to freeze in the contain-
Clay CAS 1332-58-7 er or application equipment. There is no maximum air temper-
ature application limit.
LIMITATIONS: DO NOT ALLOW material to freeze. DO NOT THIN
material. APPLICATION PROCEDURE: TEXTROFLASH LIQUID VP can be
applied by spray or brush in one or two coats to an application of
STORAGE: Textroflash Liquid VP must be kept from freezing. 35 mils wet, which will yield 20 mils dry. These applications rate
equate to an application rate of 40 square feet per gallon. The
APPLICATION: Textroflash Liquid VP must be applied to a sur-
coating will be dry to the touch within 10 minutes, but should be
face that is free from all foreign matter. This material should
allowed to cure for 4-24 hours after application. TEXTROFLASH
remain dry until it has cured. This material can be applied by
LIQUID VP is self-priming and does not require the use of a
brush, squeegee, or spray equipment and should yield a cover-
primer. It has been tested compatible with all ABAA certified tran-
age rate of 40 square feet per gallon.
sition membranes and can be applied below and/or above these
membranes. TEXTROFLASH LIQUID VP is compatible with all
INSTALLATION INSTRUCTIONS
substrates listed in the introduction to the installation instructions.
TEXTROFLASH LIQUID VP is brush or spray applied in one or It is not recommended for application to polyethylene surfaces.
two coats to the exterior vertical or horizontal surfaces of sur-
faces of cast-in-place concrete, concrete masonry units, wood, SURFACE TEMPERATURES AND CHEMICAL RESISTANCE:
metal, ICF and OSB. TEXTROFLASH LIQUID VP is resistant to chemical attack and
is very resistant to acids and salts. It should not be applied on
SUBSTRATE PREPARATION: The surface to which TEXTROFLASH surfaces that exceed 210F.
LIQUID VP is applied must be structurally sound, clean and dry and
free of dust, mud, loose mortar, sand, soil, frost or other loose CLEAN UP: TEXTROFLASH LIQUID VP can be cleaned while
materials. Additionally, there must be no fins, metal projections or wet with soap and water. If the TEXTROFLASH LIQUID VP has
any substance that will prevent bonding of the coating membrane cured; it can be removed with mineral spirits or H&B TAR &
to the surface. Voids in concrete, tie holes and honeycombed areas ASPHALT REMOVER.

ABOVE GRADE - TESTING REPORT


For Accreditation by: MSMT Designation 423 6.0 Heat Test (ASTM D 2939-98)
Sample ID: TEXTROFLASH LIQUID VP Temperature of Test: The test was conducted at 100C.
Report # EX27B7A Data: H&B TEXTROFLASH LIQUID VP shows no signs blistering, sag-
Project ID: EX27B7A ging, or slipping.
1.0 Weight per Gallon (ASTM D 2939-98) 7.0 Flexibility at 60F (ASTM D 2939-98)
Data: H&B TEXTROFLASH LIQUID VP yields 9.23 lb/gallon. Data: H&B TEXTROFLASH LIQUID VP yields a rating of 1 (no cracking or loss
of adhesion).
2.0 Residue by Evaporation (ASTM D 2939-98)
Temperature of Test: The testing was conducted at 105C. 8.0 Resistance to Water (ASTM D 2939-98)
Data: H&B TEXTROFLASH LIQUID VP averages 49.70% solids. Data: H&B TEXTROFLASH LIQUID VP shows no blistering or reemulsification.

3.0 Flammability (ASTM D 2939-98) 9.0 Direct Flame Test (ASTM D 2939-98)
Data: H&B TEXTROFLASH LIQUID VP show no tendency to flash or ignite. Data: H&B TEXTROFLASH LIQUID VP chars in place.

4.0 Ash Content (ASTM D 2939-98) Air Permeance Evaluation (ASTM E 2178)
Conditions: 600C Data: H&B TEXTROFLASH LIQUID VP Modified Emulsion Coating
Data: H&B TEXTROFLASH LIQUID VP averages 33.8%. achieves an air leakage rate of 0.00159 perms

5.0 Water Content (ASTM D 2939-98) Water Vapor Permeance (ASTM E 96)
Data: H&B TEXTROFLASH LIQUID VP yields 50.0% content of water. Data: H&B TEXTROFLASH LIQUID VP averages a >5.5 perm rating

5.1 Firm Set (ASTM D 2939-98) Conclusion: H&B TEXTROFLASH LIQUID VP complies to the testing
Substrate: Aluminum Panel / Thickness: 60 5 mils wet requirements in MSMT Designation 423 for cold applied Dampproofing
Data: H&B TEXTROFLASH LIQUID VP attains firm set after 24 hours. and Waterproofing materials.
Section D - Air Barrier Systems

Air & Vapor Barrier


H&B Self-Adhering Air and Vapor Barrier H&B Transition Membrane
for Textroflash Liquid
Hohmann & Barnard Self-Adhering Air and Vapor Barrier
is a complete self-adhering air and vapor barrier system that is Hohmann & Barnard Transition Membrane is used
applied to above-grade substrates. Apply horizontally or vertically to form a smooth transition from one plane to another when
over the entire surface area. The non-asphaltic, clear-adhesive using Textroflash Liquid Air and Vapor Barrier. Use as a
backing bonds to masonry, gypsum sheathing, concrete, steel and transition material over TextroflashTM Liquid where different
wood substrates. substrates meet, or at beams, columns, and similar joints
Patents Pending
or connections to provide continuity.

Available in widths from 4-72 x 50 long rolls. Other widths


H&B Self-Adhering Air and Vapor Barrier conforms available upon request.
to the following specifications: Patents Pending
. GSA; PBS PCD 07121
. USN; NAVFAC TS-07111
. Federal Construction Guide Spec; FCGS-07111
Possible LEED credits toward certification in the following categories:
. Energy & Atmosphere (EA)
. Materials & Resources (MR)
. Indoor Environmental Quality (EQ)
Manufactured from 45 % post-industrial and/or post-consumer recycled material.

H&B Self-Adhering
Air and Vapor Barrier
1 2 1

3 3

4 4

6 6
H&B Transition H&B Transition
5 Membrane
5
Membrane

1. #170 TRUSS EYE-WIRE (SEE PAGE A5) 3. H&B ST/ST TERMINATION BAR (SEE PAGE B8) 5. H&B ST/ST DRIP PLATE (SEE PAGE B7)

2. TEXTROFLASH TM
LIQUID (SEE PAGE D4) 4. TEXTROFLASH TM
FLASHING (SEE PAGE B4) 6. MORTAR NET (SEE PAGE A21)

D8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Material Conformance
SHEET STEEL ITEMS WIRE ASTM A 82 (Tensile Strength)

MATERIALS: FINISHES:
Plates and bars: ASTM A 36 Brite Basic:
Sheets-cold rolled: ASTM A 1008, ASTM A 1008M no coating
Mill Galvanized:
FINISHES: ASTM A 641 (0.1 oz. zinc coating / ft2) ASCE 6 /
ACI 530.1 / TMS 602
Mill Galv:
Also available: ASTM A 641 Class 1 (0.4 oz. / ft2)
ASTM A 653 Class G60 (0.6 oz. zinc coating / ft2)
ASTM A 641 Class 3 (0.8 oz. / ft2)
ASCE 6 / ACI 530.1 / TMS 602
Hot Dip Galvanized:
Hot Dip Galv: ASTM A 153 Class B (1.5 oz. ft2) ASCE 6 / ACI 530.1 /
ASTM A 153 Class B (1.5 oz.zinc coating / ft2), TMS 602
ASTM A 123 (as applicable to size and form),
ASCE 6 / ACI 530.1 / TMS 602 Stainless Steel Type 304:
ASTM A 580. H&B recommends Type 304 St / St for
Stainless Steel: maximum corrosion protection.
ASTM A 666, ASTM A 480, ASTM A 240, Type 304,
2B Finish. H& B recommends Type 304 St/St for DIAMETER:
maximum corrosion protection. 9 Gauge (.148; 3.8mm; W1.7)
3/16 (.187; 4.8mm; W2.8)

EFFECTIVE STEEL AREA (IN2) 4" wall 6" wall 8" wall 10" wall 12" wall 14" wall 16" wall

#120 Truss
Standard - 9ga. S/R x 9ga. C/R .051 .050 .048 .047 .045 .044 .043
Extra Heavy - 3/16" S/R x 9ga. C/R .072 .071 .069 .068 .066 .065 .064
Super Heavy Duty - 3/16" S/R x 3/16" C/R .073 .072 .070 .069 .067 .066 .065

#220 Ladder
Standard - 9ga. S/R x 9ga. C/R .0345 .0345 .0345 .0345 .0345 .0345 .0345
Extra Heavy - 3/16" S/R x 9ga. C/R .0554 .0554 .0554 .0554 .0554 .0554 .0554
Super Heavy Duty - 3/16" S/R x 3/16" C/R .0554 .0554 .0554 .0554 .0554 .0554 .0554

IMPORTANT: Since each construction project is unique, the appropriate selection and use of any product contained herein must be
determined by competent architects, engineers and other appropriate professionals who are familiar with the specific requirements of
the project in question.

This catalog is intended as a design aid for use in North America, and on projects world-wide where North American design parameters
have been used.

The information in this catalog is provided in good faith. However, anchor and tie adequacy can be adversely affected by on-site work-
manship for which Hohmann & Barnard can accept no responsibility. Similarly, should Hohmann & Barnard products be used in con-
junction with channels or components from other manufacturers, there can be no guarantee of performance.

All application illustrations shown in the catalog are for guidance only and should not be taken as working drawings. Hohmann & Barnard
reserves the right to amend, withdraw or to make changes to products and specifications at anytime without written notice to customers,
designers and users.

It is the policy of Hohmann & Barnard to work with designers, engineers and contractors in providing suggestions and advice for the sat-
isfactory solution of anchoring problems. However, all advice and drawings provided are subject to the approval of the design team, con-
tractor and structural engineer, who take ultimate responsibility for proper product usage.

WWW.H-B.COM
HB

Hohmann & Barnard, Inc.

www.h-b.com

weanchor@h-b.com

Branch Offices and Plants:


Hauppauge, NY 631-234-0600
Jessup, MD 301-317-0090
Fort Worth, TX 817-625-9781
Chicago, IL 773-586-6700
Birmingham, AL 205-956-0046
Foamtastic
Downingtown, PA 610-873-0070

Hohmann & Barnard, Inc. is concerned about the


preservation of the environment. For further information
regarding LEED certification or the recycled content of
our products please contact us.

Printed in the USA.


Please pass this catalog on or recycle it.

2008 Hohmann & Barnard, Inc. All Rights Reserved.

You might also like