LADDER Type
#220 Ladder-Mesh #230 Ladder-Tri-Mesh #240 Ladder-Twin-Mesh #250 Ladder-Box-Mesh
Single Wythe Wall Composite Wall Composite Wall Composite Wall
Hohmann & Barnards Lox-All Truss-Mesh and Ladder-Mesh are continuous lengths
of joint reinforcement that are embedded into the horizontal mortar joint of masonry
walls. Joint reinforcement has long proven to be necessary for superior performance Standard Sizes:
of masonry wall construction. 4 wall - 16 wall. Other widths
available on special request.
Benefits:
. Greatly reduces cracking that can arise from thermal stresses. This enhances (S) Standard:
9 ga. side rods x 9 ga. cross rods
resistance to water penetration, as cracks are controlled.
. Increases lateral flexural strength. (EH) Extra Heavy:
. Bonds exterior and interior masonry wythes together in composite or cavity 3/16 side rods x 9 ga. cross rods
(SHD) Super Heavy Duty:
walls. Also bonds masonry at intersecting walls and corners. 3/16 side rods x 3/16 cross rods
. Increases elasticity and performance of masonry walls under various stresses. Finishes: Mill Galv, Hot Galv or
Features: Stainless Steel
. Butt-welding of cross rods to longitudinal rods (not more than 16o.c.). This con-
struction enhances bonding capabilities, eliminates projection of cross rods H&B products conform to ASTM
beyond the specified width of reinforcement, and prevents excessive build up of A951 standard specification for
wire in limited mortar joints. masonry joint reinforcement.
. Continuous deformation along each longitudinal rod for superior bonding perfor-
mance.
A4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Lox All Adjustable Reinforcement
TRUSS Type H&B manufactures steel wire products from a minimum of 95 %
recycled material.
#165 Adjustable Truss #170 Truss LOX ALL Stainless Steel recycled content see page 28.
Cavity / Insulated Wall Adjustable Eye-Wire
#165 & #265 - have winged loops welded to the back-up
reinforcing. The loops accept pintles to allow vertical ad-
justability while restraining transverse movement of the
two wythes. Suitable for collar joint conditions, cavity walls or
insulated walls.
. Allows
tying both wythes together.
construction of interior wythe in advance of
NEW
Now you can adapt any of the adjustable systems shown
NOW AVAILABLE...
above for seismic zones by specifying the H&B SH -
SH - SEISMIC HOOK Seismic Hook. This hook is swaged (indented) in two
places to accommodate either a 9 gauge or 3/16 continuous
wire. As shown, a channel is formed that braces the continu-
ous wire and holds it in place. Suitable for standard 3/8 joints.
Specify SH Seismic Hook with any adjustable wire, such as
#170-SH.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A5
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
2. 9 GA. OR 3/16
CONTINUOUS WIRE 1 3
4. SEISMICLIP
5. LOOP-LOKTM WASHER
(OPTIONAL )
2 4 5
Dubl Loop-LokTM systems are available without the Seismiclip Interlock System.
Specify product #180 (truss type) or #280 (ladder type).
A6 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Adjustable Reinforcement Systems
MIGHTY-LOKTM
Features:
Large diameter eyelets and pintles afford usage where high
strength requirements are present and standard eyelets and
pintles would fail (including extra-wide cavity conditions). Also
designed for usage where standard eyelets and pintles would
fail due to greater than normal misalignment of mortar joints
between the 2 wythes.
Features:
Combines Dubl Loop-LokTM Truss reinforcement with interlocking
Grip-Lok Plate. Plate accepts continuous joint reinforcing wire.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A7
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
A8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
HB-200 Systems
6
HB-200 5
Veneer Anchor System
1
4
2
Shown with Pintle,
Seismiclip & Continuous Wire
3
1. HB-200 ANCHOR
2. HB-200 PINTLE
HB-200 - 14 ga. or 12 ga. thick. Backplate portion made to accommodate
0 - 4 insulation thickness. Pintle portion available 3, 4, 4-3/4 or 5-1/4 3. INSULATION
long. Other sizes available upon request. 4. RIGID WALLBOARD
5. H&B SELF-DRILL / SELF-TAP SCREW
Finishes: Hot Galv
Stainless Steel 6. STEEL STUD
HB-200-X
Veneer Anchor System
HB-200-HS
High-Strength Veneer Anchor System
Now available for heavy-duty applications, our new HB-200-HS High-Strength Veneer
Anchor System incorporates a 1/4" diameter pintle. This heavy-duty pintle is flattened
and then serrated for superior bonding with mortar. Suitable for 3/8" mortar joints.
Ideal for usage when the offset of engagement between pintle and anchor is
greater than 1-1/4". Standard leg length will accommodate up to 2" offset while
maintaining sufficient strength. Longer leg lengths are available on special
order, subject to loading requirements. (Note: ACI 530 section 6.2 indicates
maximum offset of 1-1/4" for standard 3/16" diameter pintle.)
Also ideal for wide cavity conditions, where a standard 3/16" pintle would not
satisfy load requirements. (Note: ACI 530 section 6.2 indicates maximum allow-
able span of 4-1/2" for standard 3/16" diameter pintles.)
U.S. Patent No. 6,279,283 Please contact H&Bs technical department for further information.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A9
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
through the sheathing. The pronged legs bridge ANCHORS AND SCREWS ARE
the sheathing and abut the steel stud, affording INSTALLED BEFORE THE FIRST
BRICK IS LAID, IMPORTANT FOR
independent, positive anchorage. Compression ON-SITE VISUAL INSPECTION.
of the sheathing by positive loads is also
prevented. The pronged legs are now also rib-
stiffened and oriented closer to each other than AVAILABLE IN LEG LENGTHS
TO ACCOMMODATE 1 / 2 -
on the original DW-10-X, thus enhancing the 4-1/2 WALLBOARD / INSU-
compressive strength. Owners, architects and LATION, HOT DIP GALV. OR
TYPE 304 ST/ STEEL.
masons can be confident in the performance
of an X-SEALED metal stud /veneer wall.
The X-SEAL Anchor meets or exceeds U.S. Pats. CAN BE INSTALLED ON LARGE
requirements of the Commonwealth of 6,925,768 & 6,941,717 4 X 8 INSULATION BOARDS, RE-
DUCING HORIZONTAL JOINT SEAMS
Massachusetts State Building Code Canadian Patent BY TWO-THIRDS (FURTHER RE-
for air leakage and water penetration. Con- 2,458,008 DUCING POTENTIAL FOR AIR &
MOISTURE INFILTRATION)
tact H& B's technical dept. for test results. Other Patents Pending
3
X-SEAL TAPE 2
A 10 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
2-Seal Tie Veneer Anchor
2-SEAL TIE
An innovative single screw veneer tie for metal stud construction.
Fabricated from carbon steel with a premium quality organic polymer
coating, the 2-Seal Tie has a dual-diameter barrel with factory-
INNOVATIVE DUAL-DIAMETER installed EPDM washers to seal both the face of the insulation and
BARREL AFFORDS A TIGHT SEAL the air / vapor barrier. This is an improvement over single barrel
AT BOTH THE FACE OF INSULA-
TION AND AT THE AIR/ VAPOR
types which only seal at the insulation and render the vapor barrier
BARRIER WITH STEEL-BONDED susceptible to air and moisture infiltration if not precisely installed
EPDM WASHERS (perfectly perpendicular to the stud).
#12 SELF-DRILLING SCREW The 2-Seal TieTM Anchor meets or exceeds requirements of
INTEGRATED INTO BARREL FOR the Commonwealth of Massachusetts State
ATTACHMENT TO METAL STUD Building Code for air leakage and water penetration.
Contact H& B's technical department for test results.
Patents Pending
2 1
CONCRETE SEAL TIE
The Concrete Seal Tie accepts the 2-Seal Byna-Lok Wire Tie to
4
tie the masonry veneer to the substrate. The #14 diameter screw 3
portion has special alternating threads making it suitable for use with
concrete, CMU or brick backup, and is provided with a single EPDM
sealing washer. The special point affords easy installation into a pre-
drilled hole.
Barrel portion available in 5/8", 1", 1-1/2", 2", 2-1/2", 3" and 3-1/2"
lengths to accommodate insulation. Available Polymer Coated or
Type 304 Stainless Steel.
Available 3/16" diameter x 3", 4" or 5" long, Hot Galvanized or 3. VAPOR BARRIER
Installation chuck adapter for both the 2-Seal TieTM and Concrete Seal TieTM sold separately.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 11
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
Horizontal Joint Reinforcement Wire and Masonry Tie are snapped into 8
4
the Seismiclip and surrounded by mortar. This allows all components to
function integrally as a single unit. 9
5
The Seismiclip is an extrusion of durable, impact-resistant, rigid
P.V.C.. It features retaining ridges to ensure correct snap-in insertion
1. INSULATION
of Vee Byna-Tie and continuous wire with a multi-grooved base to
bond mortar. 2. CONTINUOUS JOINT REINFORCEMENT WIRE
3. SEISMICLIP
Seismiclip #187 - for use with 3/16 dia. Vee Byna-Tie
Seismiclip #250 - for use with 1/ 4 dia. Vee Byna-Tie 4. VEE BYNA-TIE
(Both versions can be used with either 9ga. or 3/16 dia. continuous wire.) 5. X-SEAL TAPE
IMPORTANT: All system testing was done with H&B components. We can not be held responsible for system performance if all
components are not manufactured by Hohmann & Barnard.
A 12 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Byna-Lok Wire Tie
New masonry veneer can be anchored to existing masonry, concrete or steel with the Byna-Lok Wire Tie.
Various H&B anchor systems can be fitted with the Byna-Lok Wire Tie, affording easy and secure insertion
of the continuous joint reinforcing wire. Masonry veneer walls are then reinforced in accordance with the
principles stated below. H&B recommends Stainless Steel for maximum corrosion protection.
U.S. Pats. 5,454,200 & 6,925,768 Other Patents Pending
. Swage and mild pitch on legs of the Byna-Lok Wire Tie provide an integral
track for the continuous joint reinforcement wire.
3 . Suitable for standard 3/8" mortar joint.
. More surface engagement of the continuous wire and the integral track than
2
#305 #362
Dovetail Slot Gripstay
Channel
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 13
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
#364 SV Seismic-Notch T-Lok Tie - 14 ga. or 12 ga. thick. Backplate portion made
Gripstay Anchor to accommodate 0- 4 insulation thickness. Pintle portion
available in 3, 4 or 5 long. Other sizes available upon
request.
.
conditions. Channel provided in 10 lengths.
.
Holes drilled 12" on center in channel.
Seismic-Notch Anchor available 16 ga. thick by 3",
.
4" or 5" long.
.
Other sizes available upon request.
All components available Mill Galv, Hot Galv or Stainless Steel Also suitable for use
on concrete or CMU
A 14 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Wall Ties and Anchors
VB - Vee-Byna Tie VB - Vee Byna-Tie Standard - 3/16 or 1/4 diameter.
Lengths: 3, 3-1/2, 4, 4-1/2, 5, 6, 7 and 9.
Other sizes available upon request.
For use with H&Bs DW-10 Series Anchors, X-Seal Anchors
(tying brick veneer to steel studs), or #359 Series Weld-On
Ties (tying masonry walls to steel columns).
Finishes: Mill Galv, Hot Galv, Stainless Steel
recycled material.
recycled material.
Stainless Steel recycled content see page 28.
recycled material.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 15
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
Standard Widths:
2-3/8 (for 4 block) 8 (for 10 block)
#302W Column
4 (for 6 block) 10 (for 12 block)
Web Tie
6 (for 8 block) 12 (for 14 block)
A 16 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Column and Beam Anchors
#351 #351 - 3, 5, 7 or 9 long. Other lengths available upon request.
Wire Column
Tie For anchoring masonry to structural column when masonry is
parallel to column flange.
recycled material.
recycled material.
Stainless Steel recycled content see page 28.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 17
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
(shown with optional Lok-Channel Clip) #362-C - 5 long, other lengths available in 7-1/2
increments.
Standard: 14 ga., 12 ga. or 11 ga. thick with 5/16 holes. #362-CX - 5 long, other lengths available in 7-1/2
increments. Made to order with welded legs to accom-
Finishes: Mill Galv modate any thickness insulation / wallboard.
Hot Galv
Stainless Steel U.S. Patent No. 5,063,722
#363 Flexible
Gripstay Anchor
. Gripstay Head fits any style H&B Gripstay Channel
(tying masonry to steel columns, concrete, or exist-
ing walls). Allows generous vertical adjustability
along slot of channel.
recycled material.
A 18 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Ties & Misc. Accessories
Spyra-Lox Spyra-Lox
Rebar SL 4/5 - # 4 or #5 rebars
Lap-Joint Tie SL 6/7 - #6 or #7 rebars
SL 8/9 - # 8 or #9 rebars (#9 is 1-1/8o.d. nominal, 1.27 actual)
SL 11 - #11 rebars (1-1/4 o.d. nominal, 1.41 actual)
No tools. Eliminates cumbersome procedure of tying lap-joined
rebars together in reinforced walls. Increases worker produc-
tivity. Reduces lifting-height of block over rebars. Flow through
design allows grout to uniformly encase rebars at overlap.
Finish: Mill Galv
RB & RB-Twin
Rebar Positioners
RB - 9 ga. dia. wire for 6, 8 or 12 block.
For positioning rebars in center of block. The z-shaped wire
bridges cell of block while bends rest on shell.
RB-Twin - Same as above with double loops to hold 4 rebars.
Finishes: Mill Galv, Hot Galv or Stainless Steel
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 19
Section A - Masonry Systems
Other sizes available for heavy-duty applications. Contact H&Bs technical department.
Any H&B Gripstay Welded Bolted Welded Bolted H&B #305 H&B #305
Channel Connection Connection Connection Connection Dovetail Slot Dovetail Slot
PTA Tubes
Clear butyrate tubes with compressi-
ble polyethylene filler (for use with all
PTA series anchors except PTA-422)
A 20 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Control Joints . Weep Holes . Mortar Net
Manufactured from 50 %
recycled material.
#341 Round Plastic Weep Holes #341 Series Standard - 1/4 or 3/8" outside diameter x 4" long.
#342 Rectangular Plastic Weep Holes
#342 Series Standard - 3/8" wide x 1-1/2" high x 3-1/2" long.
#341W & #342W - Provided with cotton wick attached, for place-
ment inside cavity.
#341S & #342S - Provided with screen insert ( Brass or Stainless
Steel), to prevent infiltration of insects or debris.
#341W/S & #342W/S - Provided with both wick and screen.
#343 Louvered Weep Holes #343 Standard - 2-1/4, 2-7/8 or 3-1/2 high, injection-molded flexible PVC.
#343W WilcoTM Weep Holes Available only in Gray. Rectangular closer strip prevents mortar droppings from
clogging openings. Compressible flanges for joint widths of 1/2 - 3/4.
The Mortar Net The Mortar Net - .4, 1 or 2 thick x 10 high by 5 long.
Catches and permanently suspends mortar droppings in masonry
cavity walls so water always has open flow paths to the weeps. The
unique patented dovetail shape breaks up mortar droppings and
prevents mortar damming.
1 is manufactured from 35 %
2 is manufactured from 50 %
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 21
H& B recommends Type 304 Stainless Steel for maximum protection against corrosion.
Section A - Masonry Systems
Features
. Minimum .125 6063-T5 alloy.
. Standard 204-RI clear anodized finish.*
. Overlapping blades, all at 45, with storm lip.
STYLE E
. Extruded stop for screen retention.
. Continuous weepage on bottom.
. Special custom sizes available.
.Lengths up to 8 ft. available without front mullions - continuous blade effect.
. Extruded vents can be readily made to any specified height or width
without exposed mullions.
STYLE F
E 125 F 125 12 x 4-3/4
E 128 F 128 12 x 7-3/4
E 1212 F 1212 12 x 11-3/4
E 157 F 157 15-5/8 x 7-3/4
E 1516 F 1516 15-5/8 x 15-3/4
E 162 F 162 16-1/2 x 2-3/8
E 164 F 164 16-1/2 x 4-3/4
E 168 F 168 16-1/2 x 7-3/4
E 1616 F 1616 16-1/2 x 15-3/4
E 244 F 244 24 x 4-3/4
E 248 F 248 24 x 7-3/4
E 3208 F 3208 32 x 7-3/4
E 4808 F 4808 48 x 7-3/4
Notes:
STYLE CA
Cast Aluminum
Nominal Sizes (see note below)
4 Deep WxH
Note: All extruded and cast vents can be
equipped with operable dampers & ducts
CA 825 8 x 2-1/4
CA 847 8-1/4 x 4-15/16
CA 808 8 x 7-7/8
Features
CA 123
CA 124
12 x 2-3/4
12 x 3-1/2 ..Minimum .125 thick ..Mill finish*
CA 125
CA 128
12 x 5
12 x 7-3/4 ..Rear water stop
One piece molded unit .Overlapping
Load bearing
blades
CA 162 16-1/2 x 2-3/8 Continuous bottom weepage
CA 1604 16 x 4
CA 164 16 x 4-15/16
Note:
CA 166 16 x 6
Cast aluminum vents are standard in mill finish and do not contain
CA 168 16 x 7-3/4
mortar ribs. *Also available in baked enamel at extra charge.
A 22 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Concrete Inserts
Note: LW-340 Long Wedge Insert is suitable for use at the bottom of the slab or when
additional vertical adjustability is needed. HW-340 Standard Wedge Insert must be installed
at least 1-1/2" from bottom of slab.
Performance Data A B
Shear Tension Concrete Strength Torque
All values listed are ultimate capacities in pounds which should be reduced by a C
minimum safety factor of three to determine the allowable working loads. D
F
5/8 or 3/4 dia. x 2, 2-1/2, 3 or 4 long.
Available Plain, Stainless Steel or Zinc Plated. Hot Galv available on special order.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 23
Section A - Masonry Systems
Sharktooth Inserts
Hohmann & Barnards Sharktooth Insert has various applications and is capable of developing working loads up to
8,000#/ft. in both shear and tension. It is adjustable along virtually its entire length, and also allows in and out adjustment, while still
resisting shear and tension loads. Inserts available in hot-dip galvanized or Type 304 Stainless Steel (Type 316 Stainless Steel also
available on special order). It is fabricated in lengths from 3" to 12'-0" long, and can be custom designed for project-specific appli-
cations, such as radiuses or specific lengths. The Sharktooth Insert is a new, labor-saving, pre-engineered, high-strength insert
from Hohmann & Barnard.
Features:
. Serrated shark-tooth design allows insert to resist high . Allows for substantial vertical adjustment along full length of insert.
vertical shear loads (eliminates potential for vertical slip
due to inadequate bolt torque, as with wedge style inserts). . Welded connections not required! Nut or bolt connection into
. Rebar interference not an issue (unlike post-installed insert allows for easy installation and adjustment.
expansion bolts). . Bolting hardware is U.S. standard thread (metric thread can be
. Additional rebar hairpins not required to develop published difficult to source).
Brick relief angle at concrete beam. Insert is cast into concrete walls to Cast into radial concrete to accept
Standard, economical application. accept stone anchors. Offers high handrails. Offers a high-strength,
Must maintain 1-1/2" of concrete strength connection on bridges, adjustable and bolted connection.
above and below insert. train tressels, or cubic stone appli- Eliminates field welding or post-
cations where weaker anchors are installed expansion bolts.
not acceptable.
A 24 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Sharktooth Inserts
Performs as a gravity or tieback Insert is cast into underside of con- Cast into the underside of the con-
insert when cast into precast pan- crete slab so as to accept partition crete slab to accept pipes, duct-
els. Allows for a load-bearing, fully wall restraint angles. Offers ad- work, mechanical equipment, etc.
adjustable precast panel anchoring justable top of wall connection, As an adjustable mounting insert, it
system, while eliminating field weld- eliminating post-installed drilling eliminates post-installed anchors
ing. and potential of hitting rebar. that may hit rebar or tendons in
post-tensioned slabs.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 25
Section A - Masonry Systems
#520RA
Epoxied rod/screen tube. Chemically
resecures veneer to concrete or
masonry backup.
Installation:
Drill hole and blow clean. Mixing nozzle dispenses epoxy into screen tube.
Insert tube into hole. When rod is inserted into tube, epoxy is displaced
through screen, filling any voids in the masonry structure. When cured,
epoxy forms an anchor connection that is capable of resisting positive and
negative loads.
#521RA-B
Expansion type. Mechanically resecures
veneer to concrete or masonry backup.
Supplied with pre-installed O-ring to
function as moisture drip.
Installation:
Drill hole through veneer into backup as required. With special 2-part tool,
expand inner shield, then outer shield. Fill hole with mortar.
Available 7, 8 & 9 long. Type 304 Stainless Steel rod with brass expan-
sion shields. Fits 1/2 diameter hole.
#522RA
Expansion/screw type. Mechanically
resecures veneer to wood or metal
stud backup. Supplied with pre-installed
O-ring to function as moisture drip.
Installation:
Drill hole through veneer. With special tool, install threaded portion of
anchor into wood stud, then expand outer shield into veneer. Fill hole with
mortar.
Available 7 long. Type 304 Stainless Steel. Fits 1/2 diameter hole in veneer.
A 26 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Helix Spiro-Ties
Helix Spiro-Ties are easily hammer-driven
into the substrate, where they tap a threaded
channel to produce a hold that is strong and
permanent. Available .276 (7mm) dia. x 6, 7, 8,
9, 10, 11 or 12 long. Other lengths available
upon request. Type 304 Stainless Steel.
3. With the drill set on percussion only, the tie is power driven into
position until the outer end of the tie is automatically recessed
into the face of the masonry by the installation tool.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM A 27
Section A - Masonry Systems
04 07 09 H 65 66
9- #3
#3 #3 #3 #3
0 #3
67 7-
H
02
R
#3 6 1 R
#4 05
#3 # 40 #4
#407
#406
08 4 2 4 25
#4 #4
1 2
42
3 2 #4
#4 # #4
28 1 2 3 34
#4 29 3 3 3 #4
#4 #4 #4
#4 ite
t
Ro
39
43
5 #4 41
# #4 2 44
#4
4
44
3 #4
#
0
1 X -1
0 2
45 #45 # 45 SR 1
# -1
X
SR
1 4 15 12
#5 #5 -
S RX
Channel Strut
3
Exp. Anchor
C-
Nail-In Type
Wedge Exp.
Sleeve Exp.
1 6
Embedded
X-
Concrete
SR
Screw
Bolt
Bolt
A 28 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section B - Flashing Systems
Flex-Flash Flashing
Moisture infiltration can occur at sills, projections, recesses, intersections and mortar joints.
The solution begins with proper flashing. H&Bs Flex-Flash is a 40-mil thick product for-
mulated with Elvaloy Kee*. It does not drool and combines the best features of other types
of flashing, making it a truly superior product.
For maximum protection against moisture infiltration, specify the complete Flex-Flash
Flashing System, comprised of Flex-Flash, Mortar Net and H&Bs Foam-Tite
Seal Drip Plates and Termination Bar.
At various locations in a wall system the thru-wall flashing SIKA Sikaflex-1A #260-205
and a construction sealant are used together to form a
Sonneborn Sonolastic NP1 #733
weather-tight seal, i.e. relief angles, soft joints, door and win-
dow perimeters. H&Bs Flex-Flash has been tested for Tremco Dymonic #6 or #17
adhesion and compatibility by various sealant manufacturers
(see below). In all cases, the sealant manufacturers applica-
Company Product Primer Required
tion procedure should be followed and they recommend that
field adhesion testing should be continued throughout all Dow Corning 790 & 791 1200 Prime Coat
Silicones
NOTE: When using with insulation, please verify the com- GE Silicones Silpruf SS4179
patibility with the manufacturer. Pecora 890 & 895 P-120
Tremco Spectrem 2 #10
B2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Flex-Flash Accessories
H&Bs NEW Flex-Flash Drip Edge is a 45-mil thick product formulated with
Elvaloy Kee*. The durable, factory-formed extruded drip edge is fabricated 3 wide plus
3/8 drip. Compatible for use with any H&B flashing products.
. Available in colors to match mortar and/or brick (see list below). Special colors
. available upon request.
Simply place underneath our Flex-Flash Flashing for the ultimate protection against moisture penetration at corners and end dams.
4
4 4
4
4 4
4 4
4
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B3
Section B - Flashing Systems
Textroflash Flashing
H&B TextroflashTM Green
Thru-Wall Flashing / Surface-Mounted Flashing
Manufactured from 45 %
post-industrial and/or post-consumer
recycled material.
B4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
H&B's NEW Flash-N-Drain multi-purpose membrane is the best combination
of ease-of-use and cost effectiveness for masonry cavity wall construction. This
unique product allows you to flash your walls and effectively drain the cavity with
the easy installation of the one product. Flash-N-Drain is comprised of a
dual-layered Elvaloy membrane, one side of which is ribbed in a continuous,
vertical zigzag pattern and covered with a fine mesh scrim.
Install Flash-N-Drain vertically onto the backup wall (as a thru-wall installa-
tion or fasten with H&B's Termination Bar), drape it across the cavity on a slight
downward incline, and cut flush with the face of the masonry wall. The scrim acts
as a bond-break so mortar will not clog the continuous vertical ribs of the
membrane. This allows any moisture entering the cavity (through wind-driven
rain, suction, condensation, etc.) to find its way into the channels created by the
vertical ribs and then out of the exterior wall.
Flashings
H&B Copper-TuffTM Copper Thru-Wall Flashing
Copper-Tuff s patented super-strong polymer coating is bonded to a 2 oz. copper
sheet for maximum performance at an economical price. A fiberglass scrim is embed-
ded between this coating and copper for excellent puncture and tear resistance.
. 2 oz. has more than twice the tensile strength of typical 5 oz. copper fabric flashing.
. Compatible with ACQ and all other treatments for pressure-treated lumber.
. Lightweight and flexible; easily conforms to any surface.
Also available with 3, 5, or 7 oz. copper sheet
Widths available: 12, 16, 18, 20, 24 & 36 wide x 25 long
ASTM D 412C Tensile Strength 137,000 psi 59,000 33,700 44,300 36,300
Elongation 3% 2% 4% 2% 2%
ASTM D 1004 Graves Tear
MD 23.3 lbf. 34.7 38.1 28.4 48.0
ff !
is Ruff-n-Tu
T his stuff
(at max. load) 0.05 0.05 0.04 0.06 0.06
TD 41.1 lbf. 38.0 40.1 26.7 47.2
(at max. load) 0.05 0.05 0.05 0.05 0.06
Asphalt-free composition compatible
ASTM D 1938 Tear Propagation
(Trouser Tear)
with a wide variety of sealants.
MD 4.3 lbf. 2.5 5.4 3.1 4.6 Approved Sealants
TD 5.2 lbf. 5.0 6.2 5.2 8.6
Dow Corning 756 SMS Building Sealant
ASTM E 154 Puncture Resistance
Dow Corning 791 Silicone Weather-
max. load deflection at 255 lbf. 215 387 219 422
max. load 0.56 0.68 0.73 0.49 0.99 proofing Sealant
failure type rupture rupture rupture rupture rupture
U.S. Pat. No. 6,928,780
Other Patents Pending
H&B Copper-FlexTM
Copper-FlexTM is a composite membrane consisting of a polyethylene film lami-
nated to a 2 oz. copper sheet to create a superior flashing that can also serve as
a drip edge. It has a pressure-sensitive, clear adhesive that will not drool when
exposed to UV or heat.
Also available with 3, 5, or 7 oz. copper sheet
Widths available: 12, 16, 18, 20, 24 & 36 wide x 25 long
. weather environments
B6 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Flashings
C-Kraft Duplex uses the same sheet copper, but the end product is lighter weight
and slightly less expensive, due to the use of kraft paper in lieu of glass fabric. The
kraft paper is also asphalt-bonded to the copper on both sides.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B7
Section B - Flashing Systems
Metal Flashings
Section B - Flashing Systems
H&B manufactures a variety of metal flashing products and accessories to suit numerous job conditions. Products include standard
sheet flashings bent to custom sizes and shapes, pre-fabricated inside or outside corners, end dams, splice tape and reglets. Seen
below are various product styles, each of which are manufactured per the dimensional requirements of the customer. Metal flash-
ing products are manufactured from 26 ga. type 304 stainless steel and 16 or 12 oz. copper. (Lead-coated copper, terne-coated
stainless steel or other gauges are available on special order.)
Outside Corner (Thru-Wall) Inside Corner (Thru-Wall) Outside Corner (Surface-Mount) Inside Corner (Surface-Mount)
B8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Drip Plates
DP Our Standard Drip Plate, furnished with a smooth, factory-formed hemmed
edge for installation safety and uniform appearance. Fabricated from Type 304
or Type 316 Stainless Steel. Also available in copper and lead-coated cop-
per. Standard DP Drip Plates are compatible with all H&B flashing products.
DP-LB Same as above, for lip brick conditions.
FTSA Adds our optional Flash-AdhereTM Adhesive Strip* to the FTS Drip
Plate (as described above). This adhesive strip (with tear-off release
Available 1-1/2 or 3 wide (other widths paper) is factory-installed on the top side of the drip plate to aid in the
available on request). precise and permanent placement of the flashing.
U.S. Pat. No. 6,584,746 FTSA-LB Same as above, for lip brick conditions.
Other Patents Pending For corner pieces, reference inside or outside with above product numbers.
* Flash-AdhereTM Adhesive Strip is ONLY suitable for use with Flex-Flash or Copper-FlexTM Flashings.
Flex-FlashTM Flashing
Standard Brick
Flash-AdhereTM Strip
FTSA
Drip Plate
Foam-Tite SealTM
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM B9
Section B - Flashing Systems
Concrete Reglet
Attaches easily to form for poured concrete conditions.
Masonry Reglet
Embedded in mortar joint of masonry backup to accept flashing.
.. 8 lengths.
5/8 internal depth, 1-1/4 o.a. depth.
Termination Bars
Termination Bars are fabricated from type 304 stainless steel, with 1/4 holes spaced 8 on center. They are compatible
with all H&B membrane and copper-laminate flashings. Available in two styles, Type T1 and T2. Both styles are avail-
able with optional Foam-Tite SealTM to aid in inhibiting moisture infiltration. This factory-installed foam strip helps
seal small voids occuring between the termination bar and any irregular surfaces of the substrate, while
offering added protection against water penetration due to deterioration of the sealant.
Sealant
Splice Tape
Splice Tape is a 4 wide x 50 ft. roll of H&B Flex-Flash.
It is adhesive-backed, reinforced for strength and easily
cut to required lengths on site. Suitable for thru-wall or
surface-mount applications.
B10 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section C - Residential
Window Products
Wrap-N-SealTM Self-Adhering Window Wrap & Expansion Joint
Patents Pending
. Specially formulated adhesive seals
around screws, nails and staples.
Manufactured from 45 %
post-industrial and/or post-consumer
recycled material. Patents Pending
Patents
Pending
Manufactured from 45
%
post-industrial and/or post-consumer
. Adhesive-backed with removable release paper . Durable: will not rot, crack or drool like typical rubberized-
. Ease of installation: apply to clean, dry surface
. Resists tearing and slicing . 40 mil thickness, 4 x 50 ft. long rolls
asphalt adhesives
C2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Roofing Products
Trac-SealTM Manufactured from 45 %
post-industrial and/or post-consumer
Self-Adhering Roofing Underlayment recycled material.
Roofing Underlayment
H&B Roofing Underlayment is a polypropylene fabric with an anti-skid
coating. Unlike smooth-surfaced underlayments, the anti-slip walking
surface allows for steep-slope walkability. It is both lighter and stronger
than 30# felt.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM C3
Section C - Residential
Termite Shields
Copper
Termite Shield
Flashing
3
Tear-Away
Strip protects
2 copper during
installation
Sill-Seal
H&B Sill-Seal is a flexible, non-cross-linked polyethylene strip primarily used to
reduce air infiltration between the concrete foundation and sill plate. It works by
compressing to seal the gaps between the foundation wall and sill plate. Foam
C4 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Section D - Air Barrier Systems
H&B Commercial Air Barrier is an air and moisture barrier formulated from non-perforated, high-quality, non-
woven polyolefin. The sheet barrier is vapor permeable, yet helps prevent airflow and the passage of water. It
enhances the building envelope with a number of features in a functional, lightweight, easily installed membrane.
This weather barrier performs better than building paper or felt, protecting sheathing from moisture & wind-driven rain
Since it is non-absorbant it stays flat and tear-resistant. H&B Commercial Air Barrier allows the passage of vapor
(vapor permeable) to the outside of the building it, thus deterring mold & rot.
Ease of Installation -
extremely pliable material, for simple and easy forming
of corners.
Lightweight -
enables worker to handle and install rapidly.
Minimizes seams -
available in large format 5 ft or 10 ft wide rolls, reducing
overlaps and seams, thus reducing labor and material
costs.
D2 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Residential Air Barrier
H&B Residential Air Barrier is an air and moisture barrier formulated from non-perforated, high-quality, nonwoven
polyolefin. The sheet barrier is vapor permeable, yet helps prevent airflow and the passage of water. It enhances the
building envelope with a number of features in a functional, lightweight membrane. It is puncture and tear resistant and
supports UV exposure for up to 4 months.
This weather barrier is acceptable for applications up to four stories. For applications beyond four stories, or where a com-
mercial warranty is required, H&B Commercial Air Barrier is recommended. Residential air barrier is specifically for above
grade, vertical wall surfaces.
For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM D3
Hohmann & Barnards Textroflash Liquid
is an excellent air & vapor barrier and also performs as a
moisture barrier. It allows proper drainage in various types of
wall systems and provides protection from the detrimental Why use Textroflash Liquid?
effects of air exfiltration :. VOC-Free* (complete regulation compliance) &
and infiltration, such as HAPs-Free* (other brands contain up to 30%
energy loss, condensa- hazardous chemicals, which can leach into soil
tion, efflorescence, bac- and groundwater around buildings; Textroflash
terial growth, mold, etc. Liquid is especially suitable for schools)
More environmentally
friendly than other :. User-friendly - ready to use (no lengthy training,
spray-applied products, as with products requiring on-site mixing)
* Volatile Organic Compounds are converted into ground level ozone when combining with the nitrogen
oxides from sunlight. Ground level ozone has been found to be a public health hazard. VOCs can also
pollute soil and groundwater if accidentally released from various industrial products. Hazardous Air Pollutants
are pollutants that may cause cancer or other serious health effects and have adverse environmental and ecological
effects. Both are coming under stricter limits and regulations in various states.
PRODUCT DATA
COMPOSITION:
WATERPROOFING
Asphalt CAS 8052-42-4
TEXTROFLASH LIQUID MODIFIED EMULSION
Water CAS 7732-18-5
COATING SPRAY & BRUSH GRADE FORMULA
Polymers CAS Mixture
PRODUCT DESCRIPTION: H&Bs TEXTROFLASH LIQUID Modified Clay CAS 14808-60-7
Emulsion Coating is a latex-modified asphalt emulsion and is 100% Pigment Disperser CAS Mixture
ASBESTOS-FREE. This material is an asphalt emulsion with poly-
mers and specialty additives to formulate a waterproof coating. LIMITATIONS: DO NOT ALLOW material to freeze. DO NOT THIN mate-
rial. DO NOT heat product over 160F as this can damage material.
BASIC USES: H&Bs TEXTROFLASH LIQUID Modified Emulsion
Coating is used as a protective coating for a variety of applications STORAGE: H&Bs TEXTROFLASH LIQUID Modified Emulsion
on asphalt, metal, masonry, and foam surfaces. Coating must be kept from freezing.
The following equipment is recommended for spraying: APPLICATION: H&Bs TEXTROFLASH LIQUID Modified Emulsion
Coating must be applied to a surface that is free from all foreign
Pump GH 833 PSI 1700-1850 PSI matter. This material should remain dry until it has cured. This
Spray Gun BLUE TEXTURE Spray Tip GHD 661 material can be applied by brush, squeegee, or spray equipment
Filters Remove any and should yield a coverage rate of 1 gallon per 25 square feet
internal filters from pumping system for non-vapor-permeable. (40 mils)
1.0 Air Permeance Evaluation (ASTM E 2178) 1.0 Hydrostatic Pressure over Cracks (ASTM C 1306)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating achieves Result: H&B TEXTROFLASH LIQUID achieves a pass value of 3.75 psi
an air leakage rate of 0.00159 L/s/m2 at 75 Pa in the rapid test and a pass value of 2.5 psi in the long term test.
2.0 Water Vapor Permeance (ASTM E 96)
2.0 Low-Temperature Flexibility and Crack Bridging (ASTM C 836,
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
Section 6.7)
a 0.1 Perm rating
Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
3.0 Elongation & Tensile Strength (ASTM D 412-98a (2002) el) AC-29, Table 1 (ASTM C 836, Section 6.7) for Low Temperature
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages Flexibility and Crack Bridging. No Cracking or loss of adhesion.
41.3 psi tensile strength and 969.01% elongation
3.0 Adhesion Strength to Poured Cement (ASTM C836, Section
4.0 Water Absorption (ASTM D 570-98) 6.10)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 4.63% Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
water absorption 13.239 lbf/in. adhesion strength to poured cement
5.0 Adhesion Strength to Poured Cement (ASTM D903-98) 3.1 Adhesion Strength to Masonry (ASTM C836, Section 6.10)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating aver-
13.239 lbf/in. adhesion strength to poured cement ages 12.092 Lbf/in. adhesion strength to masonry
5.1 Adhesion Strength to Masonry (ASTM D903-98)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 4.0 Resistance to Water (ASTM D 2939, Section 15)
12.092 Lbf/in. adhesion strength to masonry Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
AC-29, Table 1 (ASTM D2939, Section 15) for Resistance to Water. No
6.0 Proportion of Solids (ASTM D 2697-86 (1998)) Blistering or Re-emulsification
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
65.62% solids 5.0 Remain in place during application (ASTM C 836, Section 6.9)
Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
7.0 Volatile Content (ASTM D 3960) AC-29, Table 1 (ASTM D2939, Section 15) for the ability to remain in
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages place during application. The final thickness after 24 hours was 0.0162
0.52% volatile content in.
8.0 Nail Sealability (ASTM D 1970)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating shows no 6.0 Water Vapor Permeance (ASTM E 96)
leaks when tested in accordance with ASTM D 1970 Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating aver-
ages a 0.1 Perm rating
9.0 Pull Adhesion to Poured Cement (ASTM D 4541)
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages 77.2 7.0 Extensibility after Heat Aging (ASTM C 836, Section 6.12)
psi pull adhesion Result: H&B TEXTROFLASH LIQUID meets the requirements of ICC
AC-29, Table 1 (ASTM C836, Section 6.12) for Extensibility after Heat
9.1 Pull Adhesion to Masonry (ASTM D 4541) Aging. Pass 1/4 inch stretch with no cracking
Result: H&B TEXTROFLASH LIQUID Modified Emulsion Coating averages
106.0 psi pull adhesion Conclusion: H&B TEXTROFLASH LIQUID passes the requirements of
ICC AC-29 Table 1 for the acceptance criteria of a cold, liquid-applied,
Conclusion: H&B TEXTROFLASH LIQUID Modified Emulsion Coating has
below grade, exterior damp proofing or Waterproofing material.
completed the testing required in ABAA Material Evaluation Process for Air
Barrier Materials, Components & Assemblies February 2006 Version 1.1.
Hohmann & Barnards TextroflashTM Liquid VP is a vapor
permeable air barrier. The breathable barrier allows proper
A Greener Solution
drainage in various types of wall systems and promotes dry-
ing of the wall cavity in either direction. It provides protection When properly installed, Textroflash Liquid VP
from the effects of energy loss, condensation, efflorescence, reduces energy usage, thus reducing fossil fuel
bacterial growth and mold. More environmentally friendly than consumption
other spray-applied products, Textroflash Liquid VP is suit- (which can con-
able for application to concrete, CMU, cast-in-place concrete tribute to the
or gypsum sheathing. It can be spray-applied or brush/roller- green house
applied. After curing, Textroflash Liquid VP is a resilient, effect). Its usage
seamless membrane with water-resistant properties. may contribute
to achievement
of LEED stan-
dards for Optimizing Energy Performance.
* Volatile Organic Compounds are converted into ground level ozone when combining with the nitrogen
oxides from sunlight. Ground level ozone has been found to be a public health hazard. VOCs can also
pollute soil and groundwater if accidentally released from various industrial products. Hazardous Air Pollutants
are pollutants that may cause cancer or other serious health effects and have adverse environmental and ecological
effects. Both are coming under stricter limits and regulations in various states.
PRODUCT DATA
Textroflash Liquid VP
Emulsified Non-Fibred Asphalt Coating
PRODUCT DESCRIPTION: Textroflash Liquid VP meets ASTM-D- in the foundation wall must be filled with non-shrinking grout or
1227-87 Type III specifications. This material is an asphalt emul- an asphalt-based mastic. Where non-shrinking grout is used for
sion with selected colloids to formulate a dampproofing coating. filling voids, the grout must be allowed to cure before the mem-
brane is applied. Concrete and parged masonry surfaces must be
BASIC USES: Textroflash Liquid VP is used as protective coating for cured and dry prior to application of the liquid air barrier mem-
a variety of applications on asphalt, metal, and masonry surfaces. brane.
3.0 Flammability (ASTM D 2939-98) 9.0 Direct Flame Test (ASTM D 2939-98)
Data: H&B TEXTROFLASH LIQUID VP show no tendency to flash or ignite. Data: H&B TEXTROFLASH LIQUID VP chars in place.
4.0 Ash Content (ASTM D 2939-98) Air Permeance Evaluation (ASTM E 2178)
Conditions: 600C Data: H&B TEXTROFLASH LIQUID VP Modified Emulsion Coating
Data: H&B TEXTROFLASH LIQUID VP averages 33.8%. achieves an air leakage rate of 0.00159 perms
5.0 Water Content (ASTM D 2939-98) Water Vapor Permeance (ASTM E 96)
Data: H&B TEXTROFLASH LIQUID VP yields 50.0% content of water. Data: H&B TEXTROFLASH LIQUID VP averages a >5.5 perm rating
5.1 Firm Set (ASTM D 2939-98) Conclusion: H&B TEXTROFLASH LIQUID VP complies to the testing
Substrate: Aluminum Panel / Thickness: 60 5 mils wet requirements in MSMT Designation 423 for cold applied Dampproofing
Data: H&B TEXTROFLASH LIQUID VP attains firm set after 24 hours. and Waterproofing materials.
Section D - Air Barrier Systems
H&B Self-Adhering
Air and Vapor Barrier
1 2 1
3 3
4 4
6 6
H&B Transition H&B Transition
5 Membrane
5
Membrane
1. #170 TRUSS EYE-WIRE (SEE PAGE A5) 3. H&B ST/ST TERMINATION BAR (SEE PAGE B8) 5. H&B ST/ST DRIP PLATE (SEE PAGE B7)
2. TEXTROFLASH TM
LIQUID (SEE PAGE D4) 4. TEXTROFLASH TM
FLASHING (SEE PAGE B4) 6. MORTAR NET (SEE PAGE A21)
D8 For material conformances, submittal sheets, CAD drawings and MSDS sheets see WWW.H-B.COM
Material Conformance
SHEET STEEL ITEMS WIRE ASTM A 82 (Tensile Strength)
MATERIALS: FINISHES:
Plates and bars: ASTM A 36 Brite Basic:
Sheets-cold rolled: ASTM A 1008, ASTM A 1008M no coating
Mill Galvanized:
FINISHES: ASTM A 641 (0.1 oz. zinc coating / ft2) ASCE 6 /
ACI 530.1 / TMS 602
Mill Galv:
Also available: ASTM A 641 Class 1 (0.4 oz. / ft2)
ASTM A 653 Class G60 (0.6 oz. zinc coating / ft2)
ASTM A 641 Class 3 (0.8 oz. / ft2)
ASCE 6 / ACI 530.1 / TMS 602
Hot Dip Galvanized:
Hot Dip Galv: ASTM A 153 Class B (1.5 oz. ft2) ASCE 6 / ACI 530.1 /
ASTM A 153 Class B (1.5 oz.zinc coating / ft2), TMS 602
ASTM A 123 (as applicable to size and form),
ASCE 6 / ACI 530.1 / TMS 602 Stainless Steel Type 304:
ASTM A 580. H&B recommends Type 304 St / St for
Stainless Steel: maximum corrosion protection.
ASTM A 666, ASTM A 480, ASTM A 240, Type 304,
2B Finish. H& B recommends Type 304 St/St for DIAMETER:
maximum corrosion protection. 9 Gauge (.148; 3.8mm; W1.7)
3/16 (.187; 4.8mm; W2.8)
EFFECTIVE STEEL AREA (IN2) 4" wall 6" wall 8" wall 10" wall 12" wall 14" wall 16" wall
#120 Truss
Standard - 9ga. S/R x 9ga. C/R .051 .050 .048 .047 .045 .044 .043
Extra Heavy - 3/16" S/R x 9ga. C/R .072 .071 .069 .068 .066 .065 .064
Super Heavy Duty - 3/16" S/R x 3/16" C/R .073 .072 .070 .069 .067 .066 .065
#220 Ladder
Standard - 9ga. S/R x 9ga. C/R .0345 .0345 .0345 .0345 .0345 .0345 .0345
Extra Heavy - 3/16" S/R x 9ga. C/R .0554 .0554 .0554 .0554 .0554 .0554 .0554
Super Heavy Duty - 3/16" S/R x 3/16" C/R .0554 .0554 .0554 .0554 .0554 .0554 .0554
IMPORTANT: Since each construction project is unique, the appropriate selection and use of any product contained herein must be
determined by competent architects, engineers and other appropriate professionals who are familiar with the specific requirements of
the project in question.
This catalog is intended as a design aid for use in North America, and on projects world-wide where North American design parameters
have been used.
The information in this catalog is provided in good faith. However, anchor and tie adequacy can be adversely affected by on-site work-
manship for which Hohmann & Barnard can accept no responsibility. Similarly, should Hohmann & Barnard products be used in con-
junction with channels or components from other manufacturers, there can be no guarantee of performance.
All application illustrations shown in the catalog are for guidance only and should not be taken as working drawings. Hohmann & Barnard
reserves the right to amend, withdraw or to make changes to products and specifications at anytime without written notice to customers,
designers and users.
It is the policy of Hohmann & Barnard to work with designers, engineers and contractors in providing suggestions and advice for the sat-
isfactory solution of anchoring problems. However, all advice and drawings provided are subject to the approval of the design team, con-
tractor and structural engineer, who take ultimate responsibility for proper product usage.
WWW.H-B.COM
HB
www.h-b.com
weanchor@h-b.com