2106 Tsai and Lin
development of temperature control and maximum cool sides of the conductor is called the Seebeck
power point tracking (MPPT) technologies for TEC effect. The generated Seebeck voltage, called the
and TEG applications. electromotive force (EMF), in a TEM is expressed
as
PRINCIPLE OF THERMOELECTRIC
MODULE US SDT: (4)
The construction of both TECs and TEGs is Applying the concept of energy equilibrium for
basically the same, and consequently the same steady-state analysis at both sides of the TEM, the
equivalent circuit can be used to simulate their absorbed heat generated by the thermal load, QA,
behavior. The basic unit of a TEM is a thermocouple and the liberated heat removed by the heat sink,
that consists of a p-type and n-type pellet couple QE, are, respectively, given by
interconnected by metal. A TEM has the form of
thermopiles that are connected electrically in series QA SITA 0:5I 2 R jth DT (5)
to increase the operating voltage and thermally in and
parallel to decrease the thermal resistance, and is
sandwiched between two ceramic plates for uniform QE SITE 0:5I 2 R jth DT: (6)
thermal expansion. There are four main energy
processes taking place in the TEM pellets: thermal The TEMs output voltage is then
conduction, Joule heating, the Peltier cooling/heat-
V US IR: (7)
ing effect, and the Seebeck effect. The additional
Thompson effect, which is described by the A good TEM must combine a large Seebeck coeffi-
Thompson coefficient s dS=dT; is small enough to cient S with low electrical resistance R and low
be neglected. Both ceramic plates and intercon- thermal conductivity jth . The figure-of-merit (FOM)
nected metals have high thermal conductivity to parameter is then defined as
ensure uniform temperature at either end.
Neglecting the contribution of the metal intercon- Z S2 =Rjth : (8)
nectors and ceramic plates, the analysis of a TEM
can be conducted by analyzing a single pellet or
thermocouple without loss of generality.
The phenomenon of thermal conduction is a DETERMINATION OF TEM PARAMETERS
Fourier process that is described by the thermal In general, TEC manufacturers provide the fol-
conductivity ji of the material. For a TEM with N lowing parameters to specify their products: DTmax,
thermocouples, the heat transfer of thermal con- the maximal temperature difference between the
duction in a TEM is described by cold and hot sides of the TEC; Imax and Vmax, the
Qth DTjth ; (1) current and voltage inputs to produce DTmax for a
given level of TH. The hot-side temperature of a
where jth is the thermal conductivity of the TEM working TEC is always constant and is nearly equal
and DT TE TA : Joule heating is a physical pro- to the temperature of the material used in the
cess of heat dissipation in a resistance element. The cooling system. In addition, it is easier to measure
flow of electric current through the TEM will addi- the hot-side temperature because this surface is
tionally cause resistive heating of the thermocou- always outside of the TEC device. For cooling, one
ples. The total Joule heat dissipated in an N-couple can assume that TE = TH and TA TH DT, and
TEM is QA is set to zero for thermal insolation. The tem-
perature difference can be expressed as
QJ I 2 R; (2)
DT SITH 0:5I 2 R=SI jth : (9)
where R is its electrical resistance. Irrespective of
the temperature gradient, the Joule heat can be The maximal temperature difference can be found
considered as equally divided between the two sides by taking the derivative of DT with respect to I and
of the TEM. The Peltier cooling/heat effect is a setting the result to zero. The maximal current and
phenomenon of heat absorption/dissipation by a temperature can be derived as
junction between two dissimilar materials when
electrical current flows through the junction. The Imax jth 1 2ZTH 0:5 1=S (10)
absorbed/emitted heat of an N-couple TEM is
and
QPE=PA SITE=A ; (3)
DTmax TH 1 1 2ZTH 0:5 =Z: (11)
where S is the TEMs Seebeck coefficient. When a
temperature gradient is imposed on a conductor Then, the maximal voltage can be rewritten as
under an open-circuit condition, the creation of an
electrical potential difference between the hot and Vmax STH : (12)
Model Building and Simulation of Thermoelectric Module Using Matlab/Simulink 2107
(a)
DC Power
supply
Hot_Side_Temperature
Hot-side Temperature
Current Scope
Cold_Side_Temperature
5.1333e-002
(b)
Seeback coefficient
f(u)
2.5268e-003
Seeback Coefficient f(u)
Function
FOM Function FOM
1.1909e+000
f(u)
8.7569e-001
f(u)
f(u) 1
Current Scope
Current Function
1
Hot-side Temperature
2
Cold-side Temperature
f(u) 2
Voltage Scope
Voltage Function
(c)
Fig. 1. TEC module: (a) masked implementation, (b) subsystem implementation, and (c) dialog box.
2108 Tsai and Lin
Rth Vmax Imax TH DTmax =2TH DTmax : (15) Some manufacturers give the efficiency for the
matched load gth,m. Since the matched load resis-
On the other hand, the regular parameters in the tance is matched to the internal resistance, i.e.,
datasheet of commercial TEGs include: TA = TH and RL = R, the current at the matched load is found to
TE = TC, the hot-side and cold-side temperatures; be
Wm, the power at the load matched to the internal
resistance (RL = R); Vm (=VR), the load voltage at Im SDT=2R; (26)
the matched load; and gmax
th ; the maximum thermal and the efficiency at the matched load is expressed
efficiency. Obviously, one can easily calculate the as
electrical parameters of the equivalent circuit di-
rectly from the datasheet. The electrical resistance gth;m ZDT=4 Z1:5TH 0:5TC : (27)
R and the Seebeck coefficient S of a TEG can be
expressed as The FOM of the TEG is then calculated by
2 Z 4gm m
TEG =DT gTEG 1:5TH 0:5TC : (28)
R RL V m =Wm ; (16)
Finally, the thermal resistance can be obtained.
and
S 2Vm =DT: (17) MODEL BUILDING AND SIMULATION
Given the fundamental specifications of a TEC
In fact, the efficiency of a TEG is a function of the
directly from the manufacturers datasheets, the
load. Assume that the load resistance is defined as
parameters of the proposed model can be calculated
RL = mR, where m is the resistance ratio between
by Eqs. 1820. For a cooling application, the cold-
the load and internal resistance. The current can be
side temperature of the TEC, TC, is a desired input
expressed as
and then the temperature difference can be
I SDT=1 mR: (18) obtained for a given hot-side temperature TH, i.e.,
DT TH TC . This temperature difference can be
The thermal efficiency of a TEG is defined as the ratio
of the electric power output to the thermal power
input to the hot side, which can be expressed as
(20) 10 10
Current (A)
Voltage (V)
(a)
Hot_Side_Temperature QH
Hot-side Temperature Current Scope
QC
DC-DC
Cold_Side_Temperature Converter
(b) 2.3800e-002
f(u)
Seebeck Coefficient
Seeback f(u) 1
Coefficient Current Scope
Function Current Function
-C-
f(u) 2
Resistance Function
Voltage Scope
Voltage Function
2.9813e-001
Resistance
f(u)
Hot-side
Temperature Optimal Load
1 Resistance Function
2
Cold-side
Temperature
f(u) f(u) 1.6985e+000
FOM
(c)
Fig. 3. TEG module: (a) masked implementation, (b) subsystem implementation, and (c) dialog box.
2110 Tsai and Lin
Power (W)
2 0:5
V Vmax STH DT 2DT=Z : (30) 2.5 10