NOTE: Users are not advised to enable this function when locally modifying the data
related to the OMCH. Otherwise, the automatic configuration data rollback function
may be triggered as a result of an OMCH interruption.
Note : When the period of time specified by RBKTIME has not expired. If the OMCH
is normal after its configuration data is modified or recovers to the normal state after
an interruption, and users do not require rollback in spite of an OMCH interruption, run
the MML command MOD CB to disable the automatic configuration data rollback
function. This prevents the rollback of the configuration data in the case of an OMCH
interruption
Before the period of time specified by RBKTIME expires, if the base station resets
and related conditions are met, the automatic configuration data rollback function still
takes effect after the reset.
NOTE: Run the LST TLFRSWITCH command to query the value of TLFRSWITCH
A GBTS can only serve as the proxy base station instead of the target base station.
The Proxy BTS refers to the normal base station and the Target BTS refers to the
faulty base station
Procedure:
Step 1: On the U2000, choose Device Maintenance > BTS Maintenance.
In the BTS Maintenance navigation tree, choose Config Emergent
OM Channel.
In the Config Emergent OM Channel dialog box, you can input
information about the target base station.
The right area shows the information about the GBTS that has been
configured with emergency O&M channel and the connection state.
Step 2: Set parameters for the target base station and click Connect.
Step 3: After an emergency O&M channel is successfully configured on the
target base station, a dialog box is displayed for confirmation. Click OK.
Then, on the GBSC LMT, you can see the list of base stations on which
emergency O&M channels are enabled. A GBSC supports a maximum
of 30 emergency O&M channels.
Step 4: Close the Config Emergent OM Channel dialog box.
To disable an enabled emergency O&M channel, double-click the emergency
O&M channel and click DisConnect.
Procedure
1. Click Config Emergent OM Channel on the menu bar of the LMT ,The
Config Emergent OM Channel dialog box is displayed.
2. Set related parameters in the Config Emergent OM Channel dialog box. For
details about parameter descriptions, see Table 1.
Table 1 Parameters related to the emergency OM channel configuration
Parameter Description
Quantity of BBU Subrack This parameter can be set to Single Subrack, or Multi-Subrack.
Main Control Board Indicates the subrack number of the main control board of the target base station.
Subrack No. This parameter is valid only when Quantity of BBU Subrack is set to Multi-
Subrack.
Main Control Board Slot Indicates the slot number of the main control board of the target base station.
No.
User Name Indicates the user name used for logging in to the LMT of the target base station.
Password Indicates the password used for logging in to the LMT of the target base station.
CTRLLNK Parent Node Indicates the slot number of the parent node if the proxy base station and target
Slot No. base station are interconnected. This parameter is valid only when Quantity of
BBU Subrack is set to Multi-Subrack.
CTRLLNK Parent Node Indicates the slot number of the parent port if the proxy base station and target
Port No. base station are interconnected. This parameter is valid only when Quantity of
BBU Subrack is set to Multi-Subrack.