You are on page 1of 47

AC

AC SERVO MOTOR

OPERATION MANUAL

MODEL : i 90M SERIES

ENGLISH

/ H. S. Global Service Network CHINA


/ SERVICE HOTLINE : +886-2-2676-5203 : +86-21-64901024
/ FAX : +886-2-2689-6600, 2689-3657 : +86-21-54570064
/ E-MAIL: service@hohsing.com.tw : http: // www.hohsing.com
/ WEBSITE: http: // www.hohsing.com

HSVP9MU01 - 2 2013.01
: i 90M


1. 1
2.
2.1 2
2.2 2
2.3 3
2.4 ( ) 3
2.5 3

3.
3.1 4
3.2 380 V 220 V 4
3.3 220 V 220 V 5
3.4. (Solenoid) ( DC : 24 V 30 V ) 5

4. LED
4.1 6
4.2 6

5.
5.1
7
5.2 7
5.3 7
5.4 8

6.
6.1 C-60M / C-300M
9
6.2 C-60M
12

7. /
ER0. 13

8.
8.1 A 14
8.2 B 16

A :
1. i 90M- 4 -7W A
2. i 90M- 4 -BR (T8) A
3. i 90M- 4-11 (Y6)
B
4. i 90M- 4 -66 (07)(V7)(V8)
B
C
5. i 90M- 4 -98
6. i 90M- 4 -DW (46) (LT) C
7. i 90M- 4 ED D

EC - Manufacturer Declaration

EC Declaration of Conformity EG Konformittserklrung


We declare herewith that the following equipment Hiermit erklren wir, dass die Bauart des Nhmaschinenantriebes
NEEDLE POSITIONER MOTOR TYP

AC SERVO MOTOR---i 90M SERIES AC SERVO MOTOR---i 90M SERIEN

. zum Einbau in eine Nheinheit oder Nhanlage sind und dass Inbetriebsnahme so lange
. is designed to be a driver of a sewing unit or system and must not be put into commission untersagt ist, bis festgestellt wurde, dass die Nheinheit oder Nhanlag, in die dieser
until the sewing unit or system has been declared in conformity with the provision of the EC Nhmaschinenantrieb eingebaut werden soll, den Bestimmungen der EG-Maschinenrichtlinie
Machinery Directives. entspricht.

. complies with the following relevant provisions: . folgenden einschlgigen Bestimmungen entspricht
-EC Low Voltage Directive (2006/95/EC) - EG Niederspannungsrichtlinie (2006/95/EWG)
-EC Electromagnetic Compatibility Directive (2004/108/EC) - EG EMV Richtlinie (2004/108/EWG)
-EC Machinery Directive (2006/42/EC) - EG Maschinenrichtlinie (2006/42/EWG)

Applied harmonized standards, especially : Angewendete harmonisierte Normen, insbesondere


EN 60204-31 Electrical equipment of industrial machines. Particular requirements for EN 60204-31 Elektrische Ausrstung von Industriemaschinen. Besondere
sewing machines, sewing units and sewing system. Anforderungen fr Nhmaschinen, Nhanheiten und Nhanlagen.
EN 292-1 Safety of machines. EN 292-1 Sicherheit von Maschinen, Grundstzliche Terminologie und Methodik.
EN 292-2 Safety of machines, technical guidelines and specifications. EN 292-2 Sicherheit von Maschinen, Technische Leitstze und Spezifikationen.
EN 61000-6-2 EMS for industrial environment. EN 61000-6-2 EMS fr Industrie Gebrauch.
EN 61000-6-3 EMI for residential environment. EN 61000-6-3 EMI fr huslich Gebrauch.

Dichiarazione CE di conformit Dclaration CE de conformit


Con la presente dichiaramo che la costruzione del motore per macchine per cucire Par la prsente, nous dclarons que le type de fabrication du moteur pour machines coudre
TIPO DI MOTORE TYPE DE MOTEUR

AC SERVO MOTOR---i 90M SERIE AC SERVO MOTOR---i 90M

. destinata per essere incorporata in una unit di cucitura oppure in un impianto di . est destin tre intgr une unit ou un systme de couture et que sa mise en service est
cucitura. E vietata la sua messa in servizio prima che lunit o limpianto di cucitura interdite tant que lunit ou le systme de couture auquel il sera intgr nait t dclar
in cui sar incorporata sia stato dichiarato conforme alle disposizioni della direttiva conforme aux dispositions de la directive CE sur les machines.
CE per macchinari.
. rpond aux suivantes dispositions pertinentes
. conforme alle seguenti disposizioni pertinenti - Directive CE sur la basse tension (2006/95/CEE)
-Direttiva CE per bassa tensione (2006/95/CEE) - Directive CE sur la compatibilit lectromagntique (2004/108/CEE)
-Direttiva CE per compatibilit elettromagnetica (2004/108/CEE) - Directive CE sur les machines (2006/42/CE)
-Direttiva CE per macchinari (2006/42/CE)
Normes appliques aprs harmonisation, en particulier
Norme armonizzate utilizzate, in particolare EN 60204-31 quipement lectrique des machines industrielles. Rgles particulires
EN 60204-31 Equipaggiamento elettrico di macchine industriali. Esigenze speciali per pour machines coudre, units et systmes couture.
macchine per cucire, unit ed impianti di cucitura. EN 292-1 Scurit des machines, terminologie de base, mthodologie.
EN 292-1 Sicurezza di macchinari, terminologia di base e metodica. EN 292-2 Scurit des machines, principes et spcifications techniques.
EN 292-2 Sicurezza di macchinari, direttive tecniche e specifiche. EN 61000-6-2 EMS pour utilisation industrielle.
EN 61000-6-2 EMS per l'ambiente industriale. EN 61000-6-3 EMI pour utilisation rsidentiel.
EN 61000-6-3 EMI per l'ambiente residenziale.

Declarao CE de Conformidade EC Declaracin de Conformidad


Declaramos, pelo presente instrumento, que a construo do motor da mquina de costura Declaramos junto con esto que el siguiente equipo
TIPO DO MOTOR MOTOR SINCRONIZADOR

AC SERVO MOTOR---i 90M SRIE AC SERVO MOTOR---i 90M SERIE

. est destinada a ser incorporada numa unidade ou instalao de costura. Nunca . est diseado para ser un controlador de una unidad de costura o sistema y no hay que
colocar em servio antes de a unidade de costura ou a instalao de costura em que ser puesto en servicio activo hasta que la unidad de costura o sistema se ha declarado
este motor vai ser incorporado ser declarda em conformidade com o disposto na conforme a la provisin de EC Directivas Maquinarias.
directiva da CE sobre mquinas.
. Se conforma con las siguientes provisiones pertinentes
. corresponde s seguintes normas pertinentes -EC Directiva Voltaje Bajo ( 2006/95/EEC )
-Directiva CE sobre baixa tenso (2006/95/CEE) -EC Directiva Compatibilidad Electromagntica ( 2004/108/EEC )
-Directiva CE sobre compatibilidade electromagntica (2004/108/CEE) -EC Directiva Maquinaria ( 2006/42/EC )
-Directiva da CE sobre mquinas (2006/42/CE)
Aplicado normas armonizadas, especialmente
Normas harmonisadas aplicadas, em particular EN 60204-31 Equipo electrico de mquinas industrials. Requisito particular para
EN 60204-31 Equipamento elctrico de mquinas industriais. Requisitos especiais para mquinas de coser, Unidades de costura y sistema de costura.
mquinas de costura, Unidades de costura e instalaes de costura. EN 292-1 Seguridad de mquinas.
EN 292-1 Segurana das mquinas, terminologia bsica, metodologia. EN 292-2 Seguridad de mquinas, directrices tcnicos y especificaciones.
EN 292-2 Segurana das mquinas, normas bsicas tcnicas e especificaes. EN 61000-6-2 EMS para ambiente industrial.
EN 61000-6-2 EMS para ambiente industriais. EN 61000-6-3 EMI para ambiente residencial.
EN 61000-6-3 EMI para ambiente residencial.

H. S. Machinery. Co., Ltd

----------------------------------------------------------------------------------------------------
Mr. C. C. Lee Plant Manager

Declaration of Conformity for Concentration Limits
for Certain Hazardous Substances
:
We declare herewith that the following AC servo motor series products list below :

AC --- HVP-70 / HVP-90 / HVP-20 / M / i

AC Servo Motor --- HVP-70 Series / HVP-90 Series / HVP-20 Series / M Series / i Series

:
Are complies with the following directives and requirements :

1. RoHS (2002/95/EC) (2005/618/EC)


2. : (SJ/T 11363-2006)

1. European Union RoHS Directive (2002/95/EC) and the concentration limits for certain hazardous
substances (2005/618/EC)
2. Peoples Republic of China Electronic Business Standard : Requirements for concentration limits
for certain hazardous substances in electronic information products (SJ/T 11363-2006)

(,)(,,,,,...)
RoHS
:
Our product itself (motor, control box) or its packing materials and accessories (box, screws package, user
manual, sticker, label, printetc.) or the suppliers of parts and raw materials are all in conformity with the
provision of the European Union RoHS Directive and Peoples Republic of China Electronic Business
Standard to conform the following concentration limits for the six hazardous substances :

/ Hazardous Substance / Permissible Values


Lead (Pb) 240 ppm / Less than 240 ppm
Mercury (Hg) 800 ppm / Less than 800 ppm
Cadmium (Cd) 80 ppm / Less than 80 ppm
Hexavalent chromium (Cr VI) 800 ppm / Less than 800 ppm
Polybrominated Biphenyl (PBB) 800 ppm / Less than 800 ppm
Polybrominated Diphenyl ether (PBDE) 800 ppm / Less than 800 ppm

: 800 ppm
The concentration of lead in the lead-free process for PCB shall be less than 800 ppm.
: Pb+Hg+Cd+Cr VI 80 ppm
For packing materials shipped with our products or parts, the hazardous substances shall be 80 ppm or
less in sum of Pb+Hg+Cd+Cr VI.

H. S. Machinery. Co., Ltd

----------------------------------------------------------------------------------------------------
Mr. C. C. Lee Plant Manager
1. :

10 %

: AC 220V AC 380V
.
380V

45C 5C
() 30 % 95 %

3
()

()

18

-1-
2.
2.1 : ( )

(USA ) DIN

9 mm 9 mm
216 40 mm 190

70
57 57
105 105
66 70

70

2.2 :
a). i 90 b). c).

MODE L M6-55-B MODE L M6-55-B

Hazar dous voltage Hochspannung Un vol tage non ad ap te Un vol taje inadecuado Hazar dous voltage Hochspannung Un vol tage non ad ap te Un vol taje inadecuado
wi ll cause inju ry. verl et zungsgefahrl prov oque des puede pr ovocar l as wi ll cause inju ry. verl et zungsgefahrl prov oque des puede pr ovocar l as
Turn off main swi tch Bitte schalten sie den blessur es. herid as. Turn off main swi tch Bitte schalten sie den blessur es. herid as.
and wait 5 m inutes hauptschalter aus und Etein drel i nterr upteur Apagar el inter rupt or and wait 5 m inutes hauptschalter aus und Etein drel i nterr upteur Apagar el inter rupt or
bef ore opening t his warten si e 5 mi nuten, et attendr e 5 mi nutes prin ci pal y esperar 5 bef ore opening t his warten si e 5 mi nuten, et attendr e 5 mi nutes prin ci pal y esperar 5
cover . bevor si e diese avant d ouvr ir le capot. minut os antes de cover . bevor si e diese avant d ouvr ir le capot. minut os antes de
abdeckung off nen. abrir esta cubier ta. abdeckung off nen. abrir esta cubier ta.

STO P STO P

MODEL M6-55-B


Hazardo us voltage Hochspannu ng Un voltag e non ad ap te Un vo ltaje i nadecuado


will cause injur y. verl etzungsgefahr l pr ovoq ue des puede pr ovocar las
Tu rn o ff main swi tch Bitte schalt en sie den bl essur es. heri das.
and wai t 5 m inutes hauptschalt er aus und Eteindr el int err upteur Apagar el int erru ptor
befo re op ening t his wart en sie 5 m inuten, et att endre 5 min utes pri ncipal y esp er ar 5
cover. bevor sie diese avantd ouvr ir l e capot. min utos antes de
abdeckun g of fnen. abrir esta cubi erta.

STO P

8 pins



Hazardous voltage Hochspannung Un voltage non adapte Un voltaje inadecuado
will cause injury. verletzungsgefahrl provoque des puede provocar las
Turn off main switch Bitte schalten sie den blessures. heridas.
and wait 5 minutes hauptschalter aus und Eteindrel interrupteur Apagar el interruptor
before opening this warten sie 5 minuten, et attendre 5 minutes principal y esperar 5
cover. bevor sie diese avantd ouvrir le capot. minutos antes de
abdeckung offnen. abrir esta cubierta.

STOP

1).
2).
3).

-2-
2.3 :

a). (A)
: 10 mm
5 ~ 10 mm
B C
b). (B) (

(CE)
)
(B)(C)

A

2.4 () : ( / )
: ()
a). () : ()()
b). () :
()

: .


. .
/
(A)

(B)

: ()
(A)
: ()
(B)
: , ,

2.5 : :
A:
B:
C:
B D:

C A
1
A

B
2
B
D

D
3
A D

-3-
3. :
3.1 :
/
( AC220V )

OFF ON

/ ( )

( AC220V )
220 V

()
OFF ON

/ ( )

( AC380V )

OFF ON

/ ( )

1. 220 V 200 ~ 240 V


2. /

3.2 380V 220 V :

: () 220V
380V

: ()

R
L2
220 V
380 V 380 V

S
L2
220 V
220 V

T
L2
380 V
N
() L1 L1 L1
PE
G G G

1220V 1220V 1220V


Motor Motor Motor

-4-
3.3 220 V 220V :
RST :

R
S
T

MODE L M6-55- B MODE L M6-55- B

MODE L M6-55- B

Haz ardous vol t age Hochspa nnun g Un v ol at g e non adap et Un vol t aj e ni a decuad o Haz ardous vol t age Hochspa nnun g Un v ol at g e non adap et Un vol t aj e ni a decuad o
wi l l cau sei nj ury. verl et zungsg efahrl provo que des pu ede provo car l as wi l l cau sei nj ury. verl et zungsg efahrl provo que des pu ede provo car l as
Turn off main swi t ch Bi t t esch alt en si e den bl essures. he ir da .s Turn off main swi t ch Bi t t esch alt en si e den bl essures. he ir da .s
and wait 5 min ut es haup st ch alt er aus und Et ei ndrel i nt errupt eur Apag ar el i nte r up ot r and wait 5 min ut es haup st ch alt er aus und Et ei ndrel i nt errupt eur Apag ar el i nte r up ot r
Haz ardous vol t age Hochspa nnun g Un v ol at g e non adap et Un vol t aj e ni a decuad o before open ni gt hi s warten si e 5 min ut en, et at t endre 5 min ut es pri nci pal y esperar 5 before open ni gt hi s warten si e 5 min ut en, et at t endre 5 min ut es pri nci pal y esperar 5
wi l l cau sei nj ury. verl et zungsg efahrl provo que des pu ede provo car l as cover. bevo r si e di ese avant d ouv ir r el cap ot . mi nut os ant es de cover. bevo r si e di ese avant d ouv ir r le cap ot . mi nut os ant es de
Turn off main swi t ch Bi t t esch alt en si e den bl essures. he ir da .s abde ckung o f n en. ab ir r esta cu bi ert a. abde ckung o f n en. ab ir r esta cu bi ert a.
and wait 5 min ut es haup st ch alt er aus und Et ei ndrel i nt errupt eur Apag ar el i nte r up to r
before open ni gt hi s warten si e 5 min ut en, et at t endre 5 min ut es pri nci pal y esperar 5
cover. bevo r si e di ese avant d ouv ir r el cap ot . mi nut os ant es de
abde ckung o f n en. ab ir r esta cu bi ert a.

ST
OP ST
OP

ST
OP

3.4 (Solenoid) : ( DC 24 V 30 V )
(Solenoid) 24 V 30 V 30 V 24 V
J P1 JP2

: (Solenoid)

10


C8
CT2
CT1

C9

JP2
JP1
F1
15 A
F2
15 A

JP 2 JP 2
24 V 24 V
JP 1 JP 1
30 V 30 V

24 V 30 V

-5-
4. LED :
4.1 :
( )



/ /
/ .
/


STOP





//



/
.



STOP



4.2 :

, . . A B C D
, . . A B C D
. A B C D
,

: A =B =C =D =
ABC ,
D

-6-
5. :
5.1 :


1 A . 001 ~ 046
P

2 B P . 001 ~ 122

5.2 :
:

: , S A B C D

ABCD :



A B C D

1000 spm 100 spm 10 spm 1 spm

-------- 100 10 1

1000 ms 100 ms 10 ms 10 ms

0 9

: S

5.3 :
047. MAC:
S , ABCD
S

:
1. 047.MAC
2.
3. ,.

-7-
5.4
5.15.2


001. H ( spm ) 014. S B T

004. N ( spm ) 015. S B A A

005. V ( spm ) 016. S B B B

006. B ( spm ) 017. S B N

007. S ( spm ) 021. E B T

009. A ( spm ) 022. E B C C

122. H L ( spm ) 023. E B D D

024. E B N


032. B A R
040. W O N
033. B R C

092. W 1 /
034. B R N

093. W 2 / ()
010. A C D

041. T M
038. P M

082. T1
039. P S

083. T2


064. FO

065. FC

066. FD

070.HHC

:
1. ,
2.

3.

-8-
6. :
6.1 C 60M / C-300M : (C-300M )

P S

(A,B ) 2

(A,B ) 1

B (C-60M)
/

(C,D ) 2

(C,D ) 1

C (C-60M)

1). EF GH
2).
EF GH

( ) 3).010. ACD ON EF
GH

4). P1~PF ,P1~P4 15,
, 0

-9-
1).

2).

ABCD 0 F ()
EFGH 0 99

---- A=B=C=D=4

---- E = F = 15

---- G = H = 15

ABCD
EF
GH

1). :

( )
/ 2). : ( )
a.
b.
( )

1). :
LED
2). :

( AUTO ) a. EF GH

b.

- 10 -
1).,
.,

,
(C-60M)
2).[007. S]
3).[008.SLS]

,
/ ,
(C-60M) ,

,
/ ,
(C-60M) ,

,
/ ,
(C-60M) ,

ABCD , 0 F ()
/ EFGH , 0 99

ABCD , 0 F ()
/ EFGH , 0 99


(C-60M) P

/

(C-60M)
S

: ABCD
A=10B=11C=12D=13E=14F=15

- 11 -
6.2 C 60M :
6.2.1 A 001~046
a. , P b. d. A B C D
A : 002. PSL
001. H c. S e. S

. . .

P S P S P S

a. c. e.

b.
d.

6.2.2 B 047~122

a. b. P B
047.MAC


OFF ON
OFF ON .

P S P S

c. e. A B C D 1. S
: 048. N12
d. S f . S 2. :

. . .

P S P S P S

d. f.
c.
e.

6.2.3 C-60M :
ABCD :



A B C D

1000 spm 100 spm 10 spm 1 spm

-------- 100 10 1

1000 ms 100 ms 10 ms 10 ms

0 9 ,
. ABCD

. 1. S
2.

- 12 -
7. / :
ER0. :


1. (Power Module)
ER0. 1
2.


AC ( )
1. ON AC 220V , AC 380V LED
ER0. 4 2. 2 ER0. 4 380V
3. F2 (C8,C9) (F1F2)

F2

1. ON
ER0. 5 AC ( )
2.

1.
-13-

2.
ER0. 7
3.
4.

ER0. 8 CPU


1. ()
ER0. 9 () 2
2.



ER0. 11 1. 121.ANU ON


ER0. 12 ( )

:
1. ()
. 2. 075. SFM

075. SFM
8. :
8.1 A

001. H ( spm ) 50 9999

A :
002. S L M A/T
T :

003. CNR 1 ~ 100 042.CUD


9999,

004. N ( spm ) 50 8000 ()

005. V ( spm ) 50 8000 ()

006. B ( spm ) 50 8000

007. S ( spm ) 50 2000

008. S L S ( ) 0 99

037.SMP A
009. A ( spm ) 50 8000
( AUTO )


O N : ()
010. A C D ON / OFF
( ) OFF : ( )
:OFF 037.SMP B

:
011. R V M J / B J : JUKI ()
B : BROTHER ()

:
A :
012. S M S A / M / SU / SD M :
SU : CT
SD : CT
CON :
013. T Y S CON / STP / TRM STP :
TRM :


014. S B T ON / OFF O N :
OFF :

015. S B A A 0 15
014.SBT ON
016. S B B B 0 15 AB

014.SBT ON
017. S B N 0 4

018. B T 1 1 : 1 , 2 , 3 ,
BT1BT2 = 0
4,5,6,7,8
BT1BT2 = 1 8
: 9 , A , B
019. B T 2 2 C,D,E,F BT1BT2 = 9 F

:
A :
020. S ME A / SU / SD
SU : CT
SD : CT


021. E B T ON / OFF O N :
OFF :

022. E B C C 0 15 021.EBT
ON
023. E B D D 0 15 CD

- 14 -

021.EBT
024. E B N 0 4 ON

: 1 , 2 , 3 , BT3BT4 = 0
025. B T 3 3
4,5,6,7,8
BT3BT4 = 1 8
: 9 , A , B
026. B T 4 4 BT3BT4 = 9 F
C,D,E,F

027. CT () 0 990 ms / / 012.SMS


020.SME
031.SMB SUSD

/
028. S B 5 ON / OFF O N : 15
15
OFF :
/
029. S B 9 0 99
0 99 / 0 99
C 1
030. B C C C + 1 ON / OFF ON : OFF :

:
A :
031. S M B A / M / SU / SD M :
SU : CT
SD : CT

032. B A R ON / OFF O N :
OFF :
032.BAR
033. B R C 0 99 ON

032.BAR
034. B R N 0 15 ON
( 0 = )

: 1 , 2 , 3 ,
035. B T 5 5 BT5BT6 = 0
4,5,6,7,8
BT5BT6 = 1 8
: 9 , A , B
036. B T 6 6 BT5BT6 = 9 F
C,D,E,F
A :
037. S M P A / M
M :


038. P M ON / OFF O N :
OFF :
( 14 ) P1P4 0 250
039. P S 038. PM ON
( 515 ) P5PF 0 250
O N :
040. W O N ON / OFF OFF :
O N :
041. TM ON / OFF
OFF :
NOP=
U=,
D=,
US=,,,
A
DS=,,,
NOP/U/D/US/DS/
042. C U D A
UT/DT/UTS/DTS
() UT=,
DT=,
UTS=,,,
A
DTS=,,,
A
042. CUD=UDUSDS
043. UD 19999
=003. CNRx043. UD
044. P N 0 9999

045. S P -----------
C W : ( )
046. D I R ( ) CW / CCW
CC W : ( )

- 15 -
8.2 B

047. MAC ( ) 0 101

049. SPD (mm) 1 250

050. MPD (mm) 1 250

O N :
054. BK ON / OFF
OFF :

O N :( 058.TR8 )
057. TRU ON / OFF
OFF :

058. TR8 1 360

064. FO (ms) 0 990

065. FC (%) 10 90

066. FD 0 990

O N :
070.HHC ON / OFF
OFF :

NO :
075. SFM NC / NO
NC :

082. T1 (ms) 0 990

083. T2 (ms) 0 990

086. L 1 (ms) 0 990

087. L 2 (ms) 0 1500

092. W 1 / (ms) 0 980 /

093. W 2 / () (ms) 0 9990 /

094. W F (ms) 0 990 /


114. UEG 5 180

116. DRU 1 360 078.TRM RK

O N :
121. ANU ON / OFF
OFF:


122. HL ( spm ) 50 9999
001. H

- 16 -
A : / APPEDIX A :
/ CONNECTOR DIAGRAM
1. i 90M 4 7W : C
A B D

10
7 14
1 5 15
6 13
4 1 2 5 12 4 14
5 4
5 2 3 1 4 11 3 13
7 6 3 10 2 12
6 3 2 2 9 1 11
1 8
6

FOOT SWITCH ENCODER SYCHRONZER FOOT LIFTER SEWING MACHINE OPTION


C D
SEWING MACHINE OPTION
1 TRIMMER SOL. MT 5 NCL SOL. NCL

2 WIPER SOL. MW 10 +24V


FOOT SWITCH 15 OP SOL.
3 --- OP
1 +12V 4 SAFETY SW.
2 START 4 ---
5 REV. SW. 9 BTL SW.
A 3 VC
14 +5V
4 KNEE SW. +5V
6 REV. SOL. MR
5 0V 3 NEEDLE UP SW.
6 TRIMMER 7 TENSION SOL. ML 8 CKU UP SIGNAL
8 +24V 13 SH SW.
9 +24V 2 OP SW.
10 EARTH 7 PSU
FOOT LIFTER 11 --- 12 0V
B 1 A.F.L. SOL. MP
12 0V 1 +12V +12V
2 +24V
13 +24V 6 PSD
14 +24V 11 0V

2. i 90M 4 BR ( T8 ) :
B C D
A
10
1 3 5 15
4 1 4 1 4 14
4 6 13
5 2 5 2 3
7 9 2 12
6 3 6 3 1 11
10 12
6
FOOT SWITCH ENCODER FOOT LIFTER SEWING MACHINE OPTION

D
OPTION
C
FOOT SWITCH 5 NCL SOL. NCL

1 +12V
SEWING MACHINE 10 +30V
2 START 1 +30V 15 OP SOL. OP
3 VC 2 TENSION SOL. ML 4 SAFETY SW.
A 3 EARTH
4 KNEE SW.
9 BTL SW.
5 0V 4 +30V 14 +5V +5V
6 TRIMMER 5 TRIMMER SOL. MT
3 NEEDLE UP SW.
6 ---
8 CKU UP SIGNAL
FOOT LIFTER 7 +30V
+30V 13 SH SW.
1 8 WIPER SOL. MV
2 0V 2 OP SW.
9 REV. SW.
3 --------- 7 PSU
B 10 +30V
4 A.F.L. SOL. MP 11 REV. SOL. MR
12 0V
5 KNEE SW. 12 0V 1 +12V +12V
6 --------- 6 PSD
11 0V

A
3. i 90M 4 11 ( Y6 ) :
A B C D

10
1 3 5 15
4 1 6 3 4 1 14
4 6 4
5 2 5 2 5 2 3 13
7 9 2 12
6 3 4 1 6 3 1 11
10 12
6
FOOT SWITCH ENCODER SYCHRONZER FOOT LIFTER SEWING MACHINE OPTION

D
OPTION
C 5 NCL SOL. NCL
FOOT SWITCH
SEWING MACHINE 10 +30V
1 +12V
2 START
1 EARTH 15 OP SOL. OP
2 WIPER SOL. MV 4 SAFETY SW.
A 3 VC
4 KNEE SW. 3 +30V 9 BTL SW.
5 0V 4 TRIMMER SOL. MT 14 +5V +5V
6 TRIMMER 5 --- 3 NEEDLE UP SW.
6 --- 8 CKU UP SIGNAL
FOOT LIFTER 7 TENSION SOL. ML
+30V 13 SH SW.
1 8 +30V
2 0V 2 OP SW.
9 REV. SW.
B 3 --------- 7 PSU
10 0V
4 A.F.L. SOL. MP 12 0V
11 +30V
5 KNEE SW. 1 +12V +12V
12 REV. SOL. MR
6 --------- 6 PSD
11 0V

4. i 90M 4 66 ( 07 )( V8 )( V7 ) :

A B C E D F

10
1 3 5 15
4 1 4 14
4 6
5 2 1 3 13
1 1 9 12
2 7 2
6 3 2 2 1 11
3 10 12
6
RED
FOOT SWITCH ENCODER KNEE SW. FOOT LIFTER SAFETY SW. SEWING MACHINE OPTION

F
KNEE SW.
OPTION
FOOT SWITCH B 1 KNEE SW.
1 +12V 2 0V 5 NCL SOL. NCL

2 START 10 +24V
A 3 VC 15 OP SOL. OP
4 KNEE SW. SEWING MACHINE
4 +24V
5 0V 1 TRIMMER SOL.
6 TRIMMER 2 +24V
9 TL SW.
14 +5V +5V
3 +24V MT
4 WIPER SOL. MW
3 NEEDLE UP SW.
FOOT LIFTER 8 CKU UP SIGNAL
5 CONDENSED STITCH MR
C 1 +24V 13 SH SW.
D 6 +24V
2 A.F.L. SOL. MP 2 OP SW.
7 TENSION SOL. ML
8 ------ 7 PSU
SAFETY SW. 9 +24V 12 0V
1 +5V +5V 10 ------ 1 +12V +12V
E
2 SAFETY SW. 11 EARTH 6 PSD
3 0V 12 ------ 11 0V

B
5. i 90M 4 98 :
A D B C E F

10
1 5 15
4 1 4 1 4 14
2 1 3 13
5 2 5 2 1
3 2 2 12
6 3 6 3 4 2 3 1 11
6
FOOT SWITCH ENCODER SEWING MACHINE FOOT LIFTER CONDENSED SAFETY SW. OPTION
STITCH

F
CONDENSED STITCH OPTION
C 1 +24V 5 NCL SOL. NCL
FOOT SWITCH 2 CONDENSED STITCH MR 10 +24V
1 +12V
15 OP SOL. OP
2 START
3 VC SEWING MACHINE 4 +24V
A 1 +24V 9 ------
4 KNEE SW.
5 0V 2 TRIMMER SOL. MT 14 +5V +5V
6 TRIMMER 3 +24V 3 NEEDLE UP SW.
D
4 WIPER SOL. MW 8 CKU UP SIGNAL
5 +24V 13 SH SW.
FOOT LIFTER
6 NCL SOL. NCL 2 OP SW.
1 0V
7 PSU
B 2 KNEE SW.
SAFETY SW. 12 0V
3 +24V +24V
1 +24V 1 +12V +12V
4 A.F.L. SOL. MP E 2 SAFETY SW. 6 PSD
3 0V 11 0V

6. i 90M 4 DW ( 46 ) ( LT ) :

A B C E D F

10
1 3 5 15
4 1 4 14
4 6
5 2 1 3 13
1 1 9
2 7 2 12
6 3 2 2 1 11
3 10 12
6
RED
FOOT SWITCH ENCODER KNEE SW. FOOT LIFTER SAFETY SW. SEWING MACHINE OPTION

F
SEWING MACHINE
1 TRIMMER SOL. OPTION
2 +24V 5 NCL SOL. NCL
FOOT SWITCH
1 +12V 3 +24V MT 10 +24V
2 START 4 WIPER SOL. MW 15 OP SOL. OP

A 3 VC 5 TENSION SOL. ML 4 +24V


4 KNEE SW. D 6 +24V 9 CONDENSED STITCH MR
5 0V 14 +5V +5V
7 A.F.L SOL. MP
6 TRIMMER
8 +5V +5V 3 NEEDLE UP SW.
9 +24V 8 CKU UP SIGNAL
KNEE SW.
10 0V 13 SH SW.
B 1 KNEE SW. 11 EARTH 2 OP SW.
2 0V 12 SAFETY SW. 7 PSU
12 0V
FOOT LIFTER 1 +12V +12V
1 +24V SAFETY SW. 6 PSD
C +5V
2 A.F.L. SOL. MP E 1 +5V 11 0V
2 SAFETY SW.
3 0V

C
7. i 90M 4 ED :
A B

19 1
4 1
5 2
6 3
37 20
FOOT SWITCH ENCODER SEWING MACHINE

SEWING MACHINE
1 ---
FOOT SWITCH 2 +5V External
1 +12V 3 VHP variable
2 START 4 0V resister
A 3 VC 5 REV. SW.
4 KNEE SW. 6 NEEDLE UP SW.
5 0V 7 HP SW.
6 TRIMMER
8 STK SW.
9 DB2000
10 DB3000
11 SAFETY SW.
12 FAWU
13 PSD
14 BTL SW.
15 ---
16 +24V
B 17 +24V
18 ---
19 0V 0V
20 ---
21 ---
22 +12V 12V
23 ---
24 BTL LED O7
25 ---
26 +24V
27 WIPER SOL. MW
28 NCL SOL. O2
29 STK LED O6
30 STK SOL. O1
31 HP LED O5
32 HP SOL. O3
33 +24V
34 REV. SOL. MR
35 A.F.L. SOL. MP
36 TENSION SOL. ML
37 TRIMMER SOL. MT

D
MODEL : i 90M SERIES
CONTENTS

Page
1. Safety Precautions 1

2. Installation and Adjustment


2.1 Motor installation 2
2.2 Installation diagram 2
2.3 Adjustment on the belt cover 3
2.4 Install and adjust the synchronizer 3
2.5 Speed control unit adjustment 3

3. Power Connection and Grounding


3.1 Single phase and three phase connection 4
3.2 Connect a 1 / 220 V power from a 3 / 380 V power source 4
3.3 The load balance for 1 / 220 V motors used on a 3 / 220 V power source 5
3.4 How to change solenoid supply voltage (DC: 24 V OR 30 V) 5

4. 7-Segment LED Display Mode and Function Keys :


4.1 Normal mode display 6
4.2 Panel function keys adjustment 6

5. General Parameter Adjustment


5.1 How to enter each parameter mode 7
5.2 How to enter parameter value area and make adjustment 7
5.3 Machine code adjustment 7
5.4 General function parameter 8

6. Operation Box
6.1 C-60M / C-300M Operation box keys definition 9
6.2 C-60M parameter adjustment 12

7. Error Code / Basic Trouble Shooting


Error code and measurement 13

8. General Parameter List


10.1Parameter Mode Alist 14
10.2Parameter Mode Blist 16

Appendix A : Connector Panel


1. i 90M- 4 -7W A
2. i 90M- 4 -BR (T8) A
3. i 90M- 4 -11 (Y6) B
4. i 90M- 4 -66 (07)(V7)(V8) B
5. i 90M- 4 -98 C
6. i 90M- 4 -DW (46) (LT) C
7. i 90M- 4 -ED D
Bottom page 7-segment display characters compare chart
1. Safety Precaution :
Please read this manual carefully, also with related manual for the machine head before
use. For perfect operation and safety, installing and operating this product by trained
personnel is required. Also the following precaution must be taken.
.
Turn off the power, unplug the cord and wait 10 minutes before any installing, mounting, or opening the
control box cover.
This product is designed for use with specified sewing machines and must not be used for other purposes.
Only use Power Voltage indicated on the name plate of the i 90M in 10 % ranges.

Attention : If the control box is AC 220V system, please dont


connect to the AC 380V power outlet, otherwise the error
code . will occur. If that happened, please turn
off the power switch immediately and check the power
voltage. Continue supply the 380V power over 5 minutes
might damage the power board and even might endanger
the person safety.
To avoid the false operation, please keep the product away from the high electromagnetic machinery or
electro pulse generator.
Dont operate in direct sun light / outdoors area and the room temperature is 45C above or 5C under.
Dont operate near the heater / dew area and the humidity is 30 % less or 95% more.
Dont operate in dusty / evaporate / combustible gas area, and stay away from corrosive material.
Avoid power cord being applied by heavy objects or excessive force, or over bend.
Power cord must keep 3 cm or above distance to the V-belt and the pulley.
To avoid the static interference and current leakage, all grounding must be done correctly.
Use the correct connector and extension wire when connecting ground wire to Earth and secure it tightly.
Turning on the machine in the first time, use low speed to operate and check the correct rotation direction.
During machine operation, dont touch any moving parts.
All moving parts must use the protective device to avoid the body contact and objects insertion.
Maintenance and repairs must be done by the specially trained personnel.
Dont cover up motors ventilation, it can cause motor overheated.
Dont use any objects or force to hit or ram the product.
All spare parts for repair must be approved or supplied by the manufacturer.

Danger and caution signs :


Risks that may cause personal injury or risk to the machine are marked with
this symbol in the instruction manual.

This symbol indicates electrical risks and warnings.

Warranty information :
Manufacturer provide a warranty in respect of the products covered for a period of 18
months after the shipping date of the products for any defects arising in the normal course
of use of the products by customers.

-1-
2. Installation and Adjustment:
2.1 Motor installation : (Recommend table drill holes)

For USA Base For Cable For Din Base

Drill 9 mm hole Drill 9 mm hole


216 Drill 40 mm hole 190

70
table 57 table 57
105 105
66 70
70

Oil tank Oil tank Oil tank

2.2 Installation diagram:


a). Install the motor and control box b).Install the pedal with c). Install the V-Belt
under the table speed control unit

V-Belt

MODE L M6-55-B MODE L M6-55-B

Motor Motor
Hazar dous voltage Hochspannung Un vol tage non ad ap te Un vol taje inadecuado Hazar dous voltage Hochspannung Un vol tage non ad ap te Un vol taje inadecuado
wi ll cause inju ry. verl et zungsgefahrl prov oque des puede pr ovocar l as wi ll cause inju ry. verl et zungsgefahrl prov oque des puede pr ovocar l as
Turn off main swi tch Bitte schalten sie den blessur es. herid as. Turn off main swi tch Bitte schalten sie den blessur es. herid as.
and wait 5 m inutes hauptschalter aus und Etein drel i nterr upteur Apagar el inter rupt or and wait 5 m inutes hauptschalter aus und Etein drel i nterr upteur Apagar el inter rupt or
bef ore opening t his warten si e 5 mi nuten, et attendr e 5 mi nutes prin ci pal y esperar 5 bef ore opening t his warten si e 5 mi nuten, et attendr e 5 mi nutes prin ci pal y esperar 5

Control
cover . bevor si e diese avant d ouvr ir le capot. minut os antes de cover . bevor si e diese avant d ouvr ir le capot. minut os antes de
abdeckung off nen. abrir esta cubier ta. abdeckung off nen. abrir esta cubier ta.

Speed control unit


STO P

Control STO P

Box Box

pedal pedal
MODE L M6-55-B pedal
Motor
Hazar dous voltage Hochspannung Un vol tage non ad ap te Un vol taje inadecuado
wi ll cause inju ry. verl et zungsgefahrl prov oque des puede pr ovocar l as
Turn off main swi tch Bitte schalten sie den blessur es. herid as.
and wait 5 m inutes hauptschalter aus und Etein drel i nterr upteur Apagar el inter rupt or
bef ore opening t his warten si e 5 mi nuten, et attendr e 5 mi nutes prin ci pal y esperar 5
cover . bevor si e diese avant d ouvr ir le capot. minut os antes de
abdeckung off nen. abrir esta cubier ta.

STO P

Control
Box

8 pins synchronizer Connector panel

Control panel
Operation box
Hazardous voltage Hochspannung Un voltage non adapte Un voltaje inadecuado
& synchronizer
will cause injury. verletzungsgefahrl provoque des puede provocar las
Turn off main switch Bitte schalten sie den blessures. heridas.
and wait 5 minutes hauptschalter aus und Eteindrel interrupteur Apagar el interruptor
before opening this warten sie 5 minuten, et attendre 5 minutes principal y esperar 5
cover. bevor sie diese avantd ouvrir le capot. minutos antes de
abdeckung offnen. abrir esta cubierta.

Motor connector
STOP

Power input

Operation box
* All connectors must plug well

1). Motor pulley and machine pulley must properly align.


2). Cable pass through or under the working table must be secured to avoid rubbing with the V-belt
3). Use the motor base to adjust belts tension.

-2-
2.3 Adjustment on the belt cover:

10 mm a). Adjust the belt stopper (A) properly and leave about 5~10 mm space
from V-belt.
B C

Finger guard
b). Factory default, finger guard is set at position (B). (for rotation of
(CE type only) counterclockwise) For rotation of clockwise, the finger guard must
be moved to position (C) and avoiding

Belt stopper

2.4 Install and adjust the synchronizer (sensor):


a). Synchronizer installationMounting the Synchronizer onto the flange of machine pulley and fasten the
rotor by setting screws.
b). Synchronizer adjustment
Setting screw

Caution :
.
Turn OFF the power, before
Bearing cover plate
. .
making the adjustment.
Photo Plate (A)

Photo Plate (B)

Needle up position : Rotate the machine pulley to reach mechanical needle up position and turn the
photo plate (A) until its red mark is aligned with the red mark on the bearing cover
plate.
Needle down position : Rotate the machine pulley to reach mechanical needle down position and turn
the photo plate (B) until its blue mark is aligned with the red mark on the bearing
cover plate.
Note: instruction above is the standard adjustment. If you feel the position wasnt accurate, please do
the fine tuning by yourself.

2.5 Speed control unit adjustment : Components of speed control unit : see figure
A Spring for toeing forward force adjustment
decrease increase B Bolt for heeling backward force adjustment
C Treadle / Pedal arm
B D Pitman rod for Treadle / Pedal

Term of adjustment Adjustment result


C
Toeing forward Spring A move to right = force increased
1
force adjustment Spring A move to left = force decreased

Heeling backward Bolt B turn = force decreased


2
force adjustment Bolt B turn = force increased
D
decrease increase Treadle stroke Rod D secure at right = stroke is longer
A 3
adjustment Rod D secure at left = stroke is shorter

-3-
3. Power Connection and Grounding:
3.1 Single phase and three phase connection:
Green/yellow wire is the ground wire.
Single phase ( AC220V ) Brown wire

OFF ON Blue wire

To control box Green / Yellow wire ( ground wire )

Three phase ( AC220V ) Brown wire


If use a single phase power
Black wire (220 V), dont connect the
black wire.
OFF ON Blue wire

To control box Green / Yellow wire ( ground wire )

Three phase ( AC380V ) Brown wire

Black wire

OFF ON Blue wire

To control box Green / Yellow wire ( ground wire )

1. When a three phase 220 V servo motor use a single phase 200 ~ 240 V power source, only connect
brown and blue wires. Use insulating tape to wrap up the unused black wire, in order to prevent the
current leakage.
2. Green / Yellow wire must do the grounding.

3.2 How to connect a 1 / 220 V power from a 3 / 380 V power source

CautionIf the power source does not have the neutral point, then this 1 / 220 V
servo motor is not suitable for this connection. Please ask supplier to offer
our 3 / 380 V servo motor.

Caution: Must have a neutral point

R
L2
220 V
380 V 380 V

L2 S
220 V
220 V

L2 T
380 V
Neutral L1 L1 L1
N
Grounding system G G
1220V 1220V 1220V
Motor Motor Motor

-4-
3.3 The load balance for 1 / 220 V motors used on a 3 / 220 V power source.
See the following figure for the load balance.
R
S
T

MOD EL M 6-55-B

MODE L M6-55- B

MOD EL M 6-55-B

Ha zardous vol t age Hochspa nnung Un v olt ag en on adapt e Un vol t aje i nad ecuado
wi l l cau sei nj ury. verl et zungsg efahrl provoq ue des pu ede provoc ar l as
Turn off main swi t ch Bi t t esch alt en si e den ble ssures. heri das.
Haz ardous vol t age Hochspa nnun g Un v ol at g e non adap et Un vol t aj e ni a decuad o
provo que des pu ede provo car l as and wait 5 min ut es haup st ch alt er aus und E t ein drel i nt errupt eur Apaga r el ni et rrupt or
wi l l cau sei nj ury. verl et zungsg efahrl before open ni gt hi s warten si e 5 min ut en, e t at et ndre 5 mi nu et s pri nci pal y esperar 5
Turn off main swi t ch Bi t t esch alt en si e den bl essures. he ir da .s
cover. bevo r si e di ese a vant d ouvri r el cap ot. mi nut os ant es de
and wait 5 min ut es haup st ch alt er aus und Et ei ndrel i nt errupt eur Apag ar el i nte r up to r Ha zardous vol t age Hochspa nnung Un v olt ag en on adapt e Un vol t aje i nad ecuado abri r e sta cub ei rt a.
before open ni gt hi s warten si e 5 min ut en, et at t endre 5 min ut es pri nci pal y esperar 5 provoq ue des pu ede provoc ar l as abde ckung o f ne n.
wi l l cau sei nj ury. verl et zungsg efahrl
cover. bevo r si e di ese avant d ouv ir r le cap ot . mi nut os ant es de Turn off main swi t ch Bi t t esch alt en si e den ble ssures. heri das.
abde ckung o f n en. ab ir r esta cu bi ert a. and wait 5 min ut es haup st ch alt er aus und E t ein drel i nt errupt eur Apaga r el ni et rrupt or
before open ni gt hi s warten si e 5 min ut en, e t at et ndre 5 mi nu et s pri nci pal y esperar 5
cover. bevo r si e di ese a vant d ouvri r el cap ot. mi nut os ant es de
abde ckung o f ne n. abri r e sta cub ei rt a.

S T OP

ST
OP

S T OP

3.4 How to change solenoid supply voltage (DC: 24 V OR 30 V)


The JP1 is for 30 V and JP2 is for 24 V.

Caution : Before making the switch, check the machine heads Solenoid specification.

Caution :
Turn off the power and wait for 10 min.
before opening the cover.

High Voltage inside

Step 1
Remove 2 screws
of front sides right

JP 2
24 V JP 2
24 V
JP 1 JP 1
30 V 30 V

Remove 2 screws 24 V jumper setting 30 V jumper setting


of front sides left

Step 2 The power board layout :

C8
CT2
CT1

C9

JP2
JP1
F1
15 A
F2
15 A

-5-
4. 7-Segment LED Display Mode and Function Keys :
4.1 Normal mode display :
Power ON = Normal mode : See the diagram for lockstitch machine and interlock stitch machine display.

Lockstitch machine

Enter parameter
Free sewingBar tackingConstant stitch sewing /
Enter parameter value / Saving .
Start back tacking / Parameter increment
End back tacking / Parameter decrement
Needle up at machine stop. STOP
Slow start
Presser foot up at machine stop
Presser foot up after trimming.
7-segament LED.
Setting key for Number of stitches /
Number of sections / Number of times

Interlock stitch machine

Enter parameter
Enter parameter value / Saving
Parameter increment .
Parameter decrement
Needle up at machine stop.
Slow start

STOP

Presser foot up at machine stop


Presser foot up after trimming.
7-segament LED.
Special function keys

4.2 Panel function keys adjustment :


Lockstitch machine functions
Select bar tacking function, LED show .. . Press A B C D key to adjust the stitches and times

Select constant stitch sewing, LED show . . . Press A B C D key to adjust the stitches and sections.

Select start / back tacking, LED show . . Press A B C D key to adjust the stitches.

Function selection, LED above the key lighten means function enabled.

Interlock stitch machine functions


Special functions selection: A = half heelingB = trimmingC = wipingD = start constant stitch sewing.

Press any of ABC key, the icon show up which mean the corresponding function been disable. Except the D key, the icon

show up which mean the start constant stitch sewing been enable.

-6-
5. General Parameter Adjustment :
5.1 How to enter each parameter mode :

Range of
Parameter mode Operating method First display Keys
parameter
AtNormal mode
Level 1 Mode A . 001 ~ 046
Press P key

Level 2 Mode B P Turn-on power . 001 ~ 122

5.2 How to enter parameter value area and make adjustment :


Step 1 : Enter the parameter level and find the parameter.

Step 2 : After find the parameter, press the S key to enter the parameter value area. Press any of
A B C D key to adjust the parameter value.

Terms for ABCD keys in the parameter value:


KEY
VALUE
A B C D
TERMS
IN TERMS OF SPEED 1000 spm 100 spm 10 spm 1 spm

IN TERMS OF ANGLE -------- 100 10 1

IN TERMS OF TIMING 1000 ms 100 ms 10 ms 10 ms

IN TERMS OF FUNCTION FUNCTION SWAP FUNCTION SWAP

Other than the function selection, each press of the key will start change the value from 0 to 9

Note After value changed, press the S key to save the value, otherwise they will lost after turning power off.

5.3 Machine code adjustment :


Machine code 047. MAC: Enter the parameter level 2, the first parameter is the machine code.
Then press the S key to enter the parameter value area. Press ABCD key to adjust the
machine code.
After adjustment press the S key to save the setting.

Note :
1. The047.MACmachine code setting might be varies which depends on the machine head brand and model

2. Wrong machine code setting might cause machine head operation abnormal or damaged.

3. After save the machine code, the corresponding parameters will load the default value automatically.

-7-
5.4 General function parameter :
Follow the steps on section 5.15.2 to adjust the these parameters

Speed function Back tacking


001. H Maximum sewing speed ( spm ) 014. S B T Start back-tacking function selection

004. N Start back-tacking speed ( spm ) 015. S B A Setting stitches A of Start back-tacking

005. V End back-tacking speed ( spm ) 016. S B B Setting stitches B of Start back-tacking

006. B Bar-Tacking Speed ( spm ) 017. S B N Setting turns of Start Back-tacking

007. S Soft start speed ( spm ) 021. E B T End back-tacking selection

Automatic constant-stitch sewing


009. A 022. E B C Setting stitches C of End back-tacking
speed ( spm )

Upper limit of maximum speed


122. HL 023. E B D Setting stitches D of End back-tacking
( spm )

024. E B N Setting turns of End back-tacking

Bar tacking / Constant stitch


032. B A R Bar-tacking selection
Wiper / Trimmer
033. B R C Setting stitches of Bar-tacking 040. W O N Wiper function selection

034. B R N Setting turns of Bar-tacking 092. W1


Delayed timing prior to wiper
engaged

010. A C D Automatic sewing End back-tacking 093. W 2 Setting timing of wiping

038. P M Constant-stitch sewing selection


041. T M Trimmer function selection
Setting stitches for section of
039. PS 082. T1
Delayed timing prior to trimmer
Constant-stitch sewing
engaged

083. T 2 Trimming time


Automatic presser foot
Full-On time setting for foot lifting
064. FO
solenoid

Duty cycle time setting for foot lifting


065. FC
solenoid

066. FD Running-Delay time setting

070.HHC Cancel foot lifting at half-heeling pedal

NOTE:
1. When motor running, the parameter area is locked and prohibited for access. The
parameter only can be adjusted when motor stop.
2. When adjust the parameter, you must fully understand the function usage and the
setting effects. If you have doubt or question, pleas ask the customer service or
technical support to help you. Dont try to adjust blindly.
3. Caution! Wrong setting of the parameter might cause the abnormal operating and
damage the sewing machine.

-8-
6. Operation Box :
6.1 C-60M / C-300M Operation box keys definition : (C-300M dont have parameter setting function)

P S

Function KEY Operation of Sewing Machine

Double start back tacking (A,B sections)

Single start back tacking (A,B sections)

Half start back tacking (B section ) (C-60M)


Start / End
back tacking
selection
Double end back tacking (C,D sections)

Single end back tacking (C,D sections)

Half end back tacking (C section) (C-60M)

1). When the treadle is toeing down, constant-stitch sewing EFG


or H performed section by section.
2). If the treadle returns to neutral intermediately in any one section,
the machine will stop immediately. After the treadle toed down
again, the balanced stitches of EFG or H goes on.
Constant stitch 3).If the parameter010. ACDis set ON, the machine will not stop
sewing
and automatically start trimming cycle and end back tacking at
the end of the last section E or H.
4).When use P1~PF function, P1~P4 default setting is 15 stitches,
other unused sections must set 0 stitch.

-9-
1). When the treadle is toeing down, machine will start sewing. If
the treadle returns to neutral, machine will stop immediately.
Free sewing 2). When the treadle is heeling back, the trimming cycle will be
finished automatically.

When the treadle is toeing down, all the seams of Bar tacking in
ABCD sections will be completed with E times, and the trimming
cycle will be finished automatically
Bar tacking
NoteWhen the bar tack sewing start, it will not stop until the
trimming cycle finished, except for the treadle heeled back to
cancel the action.

ABCD -- stitch setting range in 0 ~ F (Note)


EFGH -- stitch setting range in 0 ~ 99

----A=B=C=D=4 stitches

---- E = F = 15 stitches
Stitch setting
selection

---- G = H = 15 stitches

Press key to select : Top ABCD


Middle EF
Bottom GH

1).In free sewing:


One touch of this key act as stitch correction. (half stitch forward)

2).In constant-stitch sewing( In Bar-tack sewing, it act as needle up )


Needle up / Forward
a. If sewing stops intermediately in one section, one press of this
stitch correction
key will raise the needle to up position.
b. If sewing stops at the end of section, one press of this key will
correct one stitch forward.

1). In Free sewing and Bar-tack sewing


One press of this key makes beep sound but no function; also LED
does not lighten up.
One-shot sewing 2). In Constant-stitch sewing
( AUTO ) a. One-shot to the pedal, automatic performed number of stitches
of EFGH sections.
b. Toeing down the pedal again to finish the rest sections until it
finish the pattern.

Trimming cycle
Enable or disable the trimming cycle.
selection

- 10 -
1).When function turn on, soft start only activated at first
Soft start run of motor start. After trimming cycle finish, it will be
(C-60M) activated again on next motor start.
2). Speed of the soft start can be set by parameter [007. S].
3). Number of stitches can be set by parameter [008.SLS].

Needle up / down Needle stop setting


when motor stop LED ON= Stop at up position
(C-60M) LED OFF=Stop at down position

Presser foot up / down Presser foot action after trimming


after trimming cycle LED ON= Automatic lift the presser foot after trimming
(C-60M) LED OFF=Presser foot not active after trimming..

Presser foot up / down Presser foot action when motor stop


when motor stop LED ON=Motor stop, presser foot goes up automatically.
(C-60M) LED OFF=Presser Foot not active when motor stop.

ABCD section value increment key, range in 0~ F.(Note)


Value increment key
EFGH section value increment key, range in 0~99.

ABCD section value decrement key, range in 0~ F.(Note)


Value decrement key
EFGH section value decrement key, range in 0~99.

Enter parameter area /


Parameter increment
(C-60M)
P Press and hold this key for 2 second to enter parameter area.
Also act as parameter increment key

Enter parameter value /


Saving
(C-60M)
S Press this key in parameter area to enter parameter value area.
Also act as the parameter value saving key.

Note : Stitches setting of ABCD sections correspond to the alphabet.


A=10B=11C=12D=13E=14F=15 stitches

- 11 -
6.2 C 60M parameter adjustment :
6.2.1 How to accessParameter Mode A parameters total from 001~046
a. InNormal modearea, press b. Use or key to find the d. Use the key under the
P key to access the mode A parameter 002. PSL A B C D area to set the value.
c. Use S key to accessvalue area e. press S key to save the value.

. . .

P S P S P S

c. Access e. Save
a. Hold for 2 sec.
b. Select
d. Adjust

6.2.2 How to accessParameter Mode B parameters total from 047~122

b. Press and hold P key and turn on the power to access the first parameter
a. If machine ON, Power OFF first.
code 047.MAC ofparameter mode B

OFF ON

OFF ON .


P S
P S

b. Use or key to find the d. Use the key under the Note: After press S key to save the
parameter 048. N12 A B C D area to set the value. value, it also automatic go back to
c. Use S key to accessvalue area e. press S key to save the value. normal mode

. . .

P S P S P S

d. Access f. Save Go back to normal mode


c. Select
e. Adjust
6.2.3 Terms for C-60M in parameter value:
Terms for ABCD area which adjust by the key in the parameter value.
Key
A B C D
Terms Value

IN TERM OF SPEED 1000 spm 100 spm 10 spm 1 spm

IN TERM OF ANGLE -------- 100 10 1

IN TERM OF TIMING 1000 ms 100 ms 10 ms 10 ms

IN TERM OF FUNCTION Mode selection


Other than the mode selection, each press the or key will circling the value from 0 to 9, the total value cant be
set lower or greater than the ranged value. When the value is the maximum ranged value, press any key of the A
BCD area will change the value back to the minimum ranged value.

Note : 1. After value changed, press the S key to save the value, otherwise they will lost after turning power off.
2. Under the parameter mode, the function keys are invalid.

- 12 -
7. Error Code / Basic Troubleshooting :
7.1 Error code and measurement :

Error Code Cause of the Problem Status and Measurement


Motor and machine will be shutting down.
1. Power module detected error.
ER0.1 Please check the power module.
2. Abnormal over current or voltage occurred..
Please check the power board over current circuitry.
Motor and machine will be shutting down.
Please check the AC power. (Too high)
If control box is AC 220V system, dont use the AC 380V power voltage,
1. When power on, detected high voltage otherwise the LED will display ER0. 4 after 2 second of power ON. If continue
2. Connect the wrong voltage or supply power is too high.
ER0. 4 3. Aluminum casing resistor for the brake circuit is defective or power supply the 380V power, the electrolytic capacitors (C8,C9) of power board will
board F2 fuse burst. burst open over a period of time and cause the fuses (F1,F2) of power input
open circuit.
Please check the power board.
Please check the aluminum casing resistor and power board F2 fuse.
Motor and machine will be shutting down..
1. When power on, detected low voltage
ER0. 5 2. Connect the wrong voltage or supply power is too low..
Please check the AC power. (Too low)
-13-

Please check the power board.

1. Bad connection at the motor connector. Motor and machine will be shutting down.
2. Synchronizer (sensor) signal error. Please check the motor or motor connectors connection.
ER0. 7 3. Machine locked or object stuck in the motor pulley. Please check the synchronizer (sensor) and its signal.
4. Sewing material is too thick. Please check machine head to see if objects stuck in the motor pulley, or rotate not smoothly.

Motor and machine will be shutting down.


ER0. 8 Operation box linked to CPU interface had communication error
Please check the operation box.

Motor still can run, but all output signals and operation boxs pattern sewing function will be invalid..
1. Machine solenoid shorted.
ER0. 9 2. Main boards power transistor is faulty.
Please check machines solenoids or the resistance value is 2 less.
Please check all the power transistors, which related to solenoid.

Motor and machine will be shutting down.


1. If parameter 121.ANU is set ON, but auto needle up is Please check synchronizers up positions signal.
ER0. 11 malfunction when the power turned on. Please check control box.
Please check machine head to see if objects stuck in motor pulley, or pulley rotate not smoothly.

Power on, no synchronizer signal or not connected (valid for under Automatic starts the clutch mode.
ER0. 12 table motor) Please check the synchronizer. (also check the connection and model)

Motor rotation icon in LED is halting and not moving. Motor stops.
1. Safety switch is either faulty or bad connection. (For interlock stitch Please check the safety switch.
. or blind stitch machine).
2. Parameter075. SFMsetting not match the machine head model.
Please check parameter table on075. SFM setting, make sure it match machine heads
safety switch
8. General Parameter List :
8.1Parameter Mode Alist
Parameter Code Parameter Function Range / Selection Description

001. H Maximum sewing speed ( spm ) 50 9999 Maximum speed adjustments

A : Toe down the pedal, soft start automatic running.


002. S L M Soft start mode selection A/T
T : After trimming, soft start automatic running on next sewing.

003. CNR Counter ratio selection 1 ~ 100 Setting the multiple to the value of 042. CUD

004. N Start back-tacking speed ( spm ) 50 8000 Start back-tacking speed adjustments

005. V End back-tacking speed ( spm ) 50 8000 End back-tacking speed adjustments

006. B Bar-Tacking Speed ( spm ) 50 8000 Repeat bar-tacking speed adjustments

007. S Soft start speed ( spm ) 50 2000 Soft start speed adjustments

008. S L S Stitch numbers for soft start ( stitches ) 0 99 Soft start stitches setting

Automatic constant-stitch sewing speed Valid only at the auto pattern sewing or one shot signalSH
009. A 50 8000 active
( spm )
Only at the last seam of pattern sewing
010. A C D Automatic sewing End back-tacking ON / OFF ONValid.
OFFInvalid.
J = JUKI mode , B = BROTHER mode.
011. R V M Back-tacking mode selection J / B JActive when motor stop or running
BActive only when motor running
Start back-tacking mode selection :
AOne shot sewing
MPedal control and motor can stop at middle way.
012. S M S Back-tacking mode selection A / M / SU / SD SUOne shot sewing but motor stops at needle up by [027.CT]
timer at end of each seam.
SDOne shot sewing but motor stops at needle down by
[027.CT] timer at end of each seam.
CONAt the end of Start back-tacking ,it continues sewing if
pedal pressed or START signal on (standing operation)
Mode selection at the end of Start STPAt the end of Start Back-Tacking, machine stops and must
013. T Y S CON / STP / TRM
back-tacking re-start by pedal command.
TRMMaking the trimming cycle once the Start Back-Tacking
finished. ( Mini Bar tacking )
Valid only when the operation panel disconnected.
014. S B T Start back-tacking function selection ON / OFF ONPerform
OFFNot perform
015. S B A Setting stitches A of Start back-tacking 0 15 stitches
Start back-tacking stitches setting ,014. SBT= ON valid
016. S B B Setting stitches B of Start back-tacking 0 15 stitches
Setting the seam times of Start back-tacking ,014. SBT= ON
017. S B N Setting turns of Start Back-tacking 0 4 turns
valid

018. B T 1 Stitch balance for Start Back-tacking 1 BT1=0:Invalid,1-8:Increase stitches of reverse seam,
9-F:Increase stitches of forward seam
0~F
BT2=0:Invalid,1-8:Increase stitches of forward seam,
019. B T 2 Stitch balance for Start Back-tacking 2 9-F:Increase stitches of reverse seam

End back-tacking mode selection. :


AOne shot sewing.
SUOne shot sewing but machine stops up position by
020. S ME Mode selection for End back-tacking A / SU / SD 027. CT timer at the end of each seam.
SDOne shot sewing but machine stops down position by
027. CT timer at the end of each seam.
Valid only when the operation panel disconnected.
021. E B T End back-tacking selection ON / OFF ONPerform
OFFNot perform

022. E B C Setting stitches C of End back-tacking 0 15 stitches


End back-tacking stitches setting ,021. EBT = ON valid
023. E B D Setting stitches D of End back-tacking 0 15 stitches

Setting the seam times of End back-tacking ,021EBT= ON


024. E B N Setting turns of End back-tacking 0 4 turns
valid
BT3=0:Invalid,1-8:Increase stitches of reverse seam,
025. B T 3 Stitch balance for End Back-tacking 3
9-F:Increase stitches of forward seam
0~F
BT4=0:Invalid,1-8:Increase stitches of forward seam,
026. B T 4 Stitch balance for End Back-tacking 4 9-F:Increase stitches of reverse seam

- 14 -
012. SMS,020. SME,031. SMB= SU,SD setting valid.
Setting time interruption at each section
027. CT 0 990 ms Conner stop timer, valid only at 012. SMS,020. SME,
end of Back-Tacking. (ms)
031. SMBsetting SU/SD.
Additional 15 stitches are added to the Start and End
15 stitches plus on Start/End back-tacking stitches function selection.
028. S B 5 ON / OFF
back-tacking ONValid.
OFF : Invalid
0-99 stitches plus on Start/End Additional setting stitches are added to the Start and End
029. S B 9 0 99 stitches
back-tacking back-tacking stitches.
Added 1 stitch to the C segment of End back-tacking function
Added 1 stitch to the C segment of End
030. B C C ON / OFF selection.
back-tacking
ONValid / OFF : Invalid
Bar-tacking mode selection. :
AOne shot sewing.
MPedal control and motor can stop at middle way.
031. S M B Mode selection for Bar-tacking A / M / SU / SD SUOne shot sewing but motor stops at needle up by 027.
CT timer at end of each seam.
SDOne shot sewing but motor stops at needle down by027.
CT timer at end of each seam.
Valid only when the operation panel disconnected.
032. B A R Bar-tacking selection ON / OFF
ONPerform / OFFNot perform.
033. B R C Setting stitches of Bar-tacking 0 99 stitches One setting for all seams ,032. BAR = ON valid.
034. B R N Setting turns of Bar-tacking 0 15 turns The seam times of Bar-tacking ,032. BAR= ON valid.
BT5=0:Invalid,1-8:Increase stitches of reverse seam,
035. B T 5 Stitch balance for Bar-tacking 5
9-F:Increase stitches of forward seam
0~F BT6=0:Invalid,1-8:Increase stitches of forward seam,
036. B T 6 Stitch balance for Bar-tacking 6 9-F:Increase stitches of reverse seam
Mode selection for Constant-stitch AOne shot sewing.
037. S M P A / M
sewing MPedal control and motor can stop at middle way.
Valid only when the operation panel disconnected.
038. P M Constant-stitch sewing selection ON / OFF ONPerform. / OFFNot perform.
Setting stitches for section 14 of
0 250 stitches
Constant-stitch sewing Stitches setting of seam P1-P4. 038. PM =ON valid.
039. P S
Setting stitches for section 5F of Stitches setting of seam P5-PF. 038. PM = ON valid.
0 250 stitches
Constant-stitch sewing
ONEnable.
040. W O N Wiper function selection ON / OFF
OFFDisable.
ONEnable.
041. TM Trimmer function selection ON / OFF
OFFDisable.
NOP : The counter is invalid.
U : Count up by stitches. When count over, counter will be
auto-reset.
D : Count down by stitches. When count over, counter will be
auto-reset.
US : Count up by stitches. When count over, motor stops and
the counter must be reset by the external switch or the A
key on the front panel..
DS : Count down by stitches. When count over, motor stops
and the counter must be reset by the external switch or
Count mode selection NOP/U/D/US/DS/
042. C U D the A key on the front panel..
UT/DT/UTS/DTS
(For Bobbin Thread or Sewing Piece) UT : Count up by trimming. When count over , counter will be
auto-reset.
DT : Count down by trimming. When count over , counter will be
auto-reset
UTS : Count up by trimming. When count over, motor stops and
the counter must be reset by the external switch or the A
key on the front panel..
DTS : Count down by trimming. When count over, motor stops
and the counter must be reset by the external switch or
the A key on the panel..
Count setting . (Note: The real number = the value of
043. UD Setting the count 19999 003.CNRX043.UD,when 042.CUD= U,D,US,DS valid
only.)
044. P N Display the current count 0 9999 Display the current count of043.UD

045. S P Sewing speed ----------- Showing the current sewing speed.


CCWCounterclockwise.
046. D I R Direction of motor rotation CW / CCW
CWClockwise.

- 15 -
8.2Parameter Mode Blist
Parameter Code Parameter Function Range / Selection Description

047. MAC Machine Code 0 101 Machine code switchover

049. SPD Machine's pulley dimension 1 250 Setting machine pulley size when051. PL = ON valid.

050. MPD Motor's pulley dimension. 1 250 Setting motor pulley size when 051. PL = ON valid.

ONEnable.
054. BK Motor braked at normal stop ON / OFF
OFFDisable.

Motor stops with a reverse angle after ONEnable.


057. TRU ON / OFF
trimming OFFDisable

058. TR8 Setting the angles of 057. TRU 1 360 Valid only when057.TRU = ON .

Full-On time setting for foot lifting


064. FO 0 990 For solenoid pulling torque adjustment.
solenoid (ms)
For solenoid's switching power adjustment.
Duty cycle time setting for foot lifting
065. FC 10 90 % Note : Wrongly adjustment will cause the solenoid
solenoid (%)
unable to lift or over-heating
If foot lifter is installed, set 100 ms min. to ensure the presser
066. FD Running-Delay time setting 0 990
foot will come down first.
ON : No foot lifting at half-heeling. (but full-heeling can
070.HHC Cancel foot lifting at half-heeling pedal ON / OFF operate foot lifter )
OFF : Operate foot lifting at half-heeling.
NONormal open. When signal at close, motor immediately
stops and rotation symbol will stop.
075. SFM Safety switch protection mode NC / NO
NCNormal close. When signal at open, motor immediately
stops and rotation symbol will stop
Delayed timing prior to trimmer
082. T1 0 990 ms Valid for079. LTM= T4/TK/TS/T7.
engaged (ms)

083. T2 Trimming time (ms) 0 990 ms Valid for079. LTM= T1/T3/T4/TK/TS/T7.

Delayed timing prior to tension release


086. L 1 0 990 ms Valid for080. LLM= L4/LK/LS/L7.
engaged (ms)
087. L 2 Timing of tension release (ms) 0 1500 ms Valid for080. LLM = L1/L3/L4/LK/LS/L7.

Delayed timing prior to wiper engaged


092. W 1 0 980 ms Time setting between needle up to wiper active.
(ms)

093. W 2 Setting timing of wiping (ms) 0 9990 ms Wiper ON timer setting.

Delayed timing prior to foot lifter


094. W F 0 990 ms Timer setting between wiper OFF to presser foot ON.
engaged (ms)

114. UEG Needle UP position stop angle 5 180 Adjust the needle up stop position.

Valid only when078. TRM=RKmode


Reverse angles through Needle down
116. DRU 1 360 Motor reverses from needle down, and stops at the needle
and up
upper dead point.
O N : Automatic needle UP at power on.
121. ANU Needle goes up as power turned ON ON / OFF
OFF : Function invalid

122. HL Upper limit of maximum speed ( spm ) 50 9999 spm The motor's maximum speed setting

- 16 -
APPEDIX A :
CONNECTOR DIAGRAM
1. i 90M 4 7W : A B C D

10
7 14
1 5 15
6 13
4 1 2 5 12 4 14
5 4
5 2 3 1 4 11 3 13
7 6 3 10 2 12
6 3 2 2 9 1 11
1 8
6

FOOT SWITCH ENCODER SYCHRONZER FOOT LIFTER SEWING MACHINE OPTION

D
C OPTION
SEWING MACHINE 5 NCL SOL. NCL

1 TRIMMER SOL. MT 10 +24V


FOOT SWITCH 15 OP SOL. OP
2 WIPER SOL. MW
1 +12V
3 --- 4 SAFETY SW.
2 START
A 3 VC 4 --- 9 BTL SW.
4 KNEE SW. 5 REV. SW. 14 +5V +5V
5 0V 6 REV. SOL. MR 3 NEEDLE UP SW.
6 TRIMMER 7 TENSION SOL. 8 CKU UP SIGNAL
ML
8 +24V 13 SH SW.
9 +24V 2 OP SW.
FOOT LIFTER 10 EARTH 7 PSU
1 A.F.L. SOL. MP 11 --- 12 0V
B +24V 12 0V 1 +12V +12V
2
13 +24V 6 PSD
14 +24V 11 0V

2. i 90M 4 BR ( T8 ) : B C D
A

10
1 3 5 15
4 1 4 1 4 14
4 6 13
5 2 5 2 3
7 9 2 12
6 3 6 3 1 11
10 12
6
FOOT SWITCH ENCODER FOOT LIFTER SEWING MACHINE OPTION

D
OPTION
C
FOOT SWITCH 5 NCL SOL. NCL

1 +12V
SEWING MACHINE 10 +30V
2 START 1 +30V 15 OP SOL. OP
A 3 VC 2 TENSION SOL. ML 4 SAFETY SW.
4 KNEE SW. 3 EARTH 9 BTL SW.
5 0V 4 +30V 14 +5V +5V
6 TRIMMER 5 TRIMMER SOL. MT
3 NEEDLE UP SW.
6 ---
8 CKU UP SIGNAL
FOOT LIFTER 7 +30V
+30V 13 SH SW.
1 8 WIPER SOL. MV
2 0V 2 OP SW.
9 REV. SW.
B 3 --------- 10 +30V
7 PSU
4 A.F.L. SOL. MP 11 REV. SOL. MR
12 0V
5 KNEE SW. 12 0V 1 +12V +12V
6 --------- 6 PSD
11 0V

A
3. i 90M 4 11 : ( Y6 )
A B C D

10
1 3 5 15
4 1 6 3 4 1 14
4 6 4
5 2 5 2 5 2 3 13
7 9 2 12
6 3 4 1 6 3 1 11
10 12
6
FOOT SWITCH ENCODER SYCHRONZER FOOT LIFTER SEWING MACHINE OPTION

D
OPTION
C 5 NCL SOL. NCL
FOOT SWITCH
SEWING MACHINE 10 +30V
1 +12V
2 START
1 EARTH 15 OP SOL. OP

3 VC 2 WIPER SOL. MV 4 SAFETY SW.


A 4 KNEE SW. 3 +30V 9 BTL SW.
5 0V 4 TRIMMER SOL. MT 14 +5V +5V
6 TRIMMER 5 --- 3 NEEDLE UP SW.
6 --- 8 CKU UP SIGNAL
FOOT LIFTER 7 TENSION SOL. ML 13 SH SW.
1 +30V 8 +30V
2 0V 2 OP SW.
9 REV. SW.
3 --------- 7 PSU
B 10 0V
4 A.F.L. SOL. MP 12 0V
11 +30V
5 KNEE SW. 1 +12V +12V
12 REV. SOL. MR
6 --------- 6 PSD
11 0V

4. i 90M 4 66 ( 07 )( V8 )( V7 ) :
A B C E D F

10
1 3 5 15
4 1 4 14
4 6
5 2 1 3 13
1 1 9
2 7 2 12
6 3 2 2 1 11
3 10 12
6
RED
FOOT SWITCH ENCODER KNEE SW. FOOT LIFTER SAFETY SW. SEWING MACHINE OPTION

F
KNEE SW.
OPTION
FOOT SWITCH B 1 KNEE SW.
1 +12V 2 0V 5 NCL SOL. NCL

2 START 10 +24V
A 3 VC 15 OP SOL. OP
4 KNEE SW. SEWING MACHINE
4 +24V
5 0V 1 TRIMMER SOL.
6 TRIMMER 2 +24V 9 TL SW.
14 +5V +5V
3 +24V MT
4 WIPER SOL. MW
3 NEEDLE UP SW.
FOOT LIFTER 8 CKU UP SIGNAL
5 CONDENSED STITCH MR
C 1 +24V D 13 SH SW.
6 +24V
2 A.F.L. SOL. MP
2 OP SW.
7 TENSION SOL. ML
8 ------ 7 PSU
SAFETY SW. 9 +24V 12 0V
1 +5V +5V 10 ------ 1 +12V +12V
E 2 SAFETY SW. 11 EARTH 6 PSD
3 0V 12 ------ 11 0V

B
5. i 90M 4 98 :
A D B C E F

10
1 5 15
4 1 4 1 4 14
2 1 3 13
5 2 5 2 1
3 2 2 12
6 3 6 3 4 2 3 1 11
6
FOOT SWITCH ENCODER SEWING MACHINE FOOT LIFTER CONDENSED SAFETY SW. OPTION
STITCH

F
CONDENSED STITCH OPTION
1 +24V 5 NCL SOL. NCL
FOOT SWITCH C 2 CONDENSED STITCH MR 10 +24V
1 +12V
15 OP SOL. OP
2 START
3 VC SEWING MACHINE 4 +24V
A 4 KNEE SW. 1 +24V 9 ------
5 0V 2 TRIMMER SOL. MT 14 +5V +5V
6 TRIMMER 3 +24V 3 NEEDLE UP SW.
D 4 WIPER SOL. MW 8 CKU UP SIGNAL
5 +24V 13 SH SW.
FOOT LIFTER
6 NCL SOL. NCL 2 OP SW.
1 0V
7 PSU
2 KNEE SW. SAFETY SW.
B 3 +24V 12 0V
1 +24V +24V 1 +12V +12V
4 A.F.L. SOL. MP
E 2 SAFETY SW. 6 PSD
3 0V 11 0V

6. i 90M 4 DW ( 46 ) ( LT ) :
A B C E D F

10
1 3 5 15
4 1 4 14
4 6
5 2 1 3 13
1 1 9
2 7 2 12
6 3 2 2 1 11
3 10 12
6
RED
FOOT SWITCH ENCODER KNEE SW. FOOT LIFTER SAFETY SW. SEWING MACHINE OPTION

SEWING MACHINE F
1 TRIMMER SOL. OPTION
2 +24V 5 NCL SOL. NCL
FOOT SWITCH
1 +12V 3 +24V MT 10 +24V
2 START 4 WIPER SOL. MW 15 OP SOL. OP
3 VC 5 TENSION SOL. ML 4 +24V
A 4 KNEE SW. 9 CONDENSED STITCH
5 0V
D 6 +24V MR
7 A.F.L SOL. MP 14 +5V +5V
6 TRIMMER
8 +5V +5V 3 NEEDLE UP SW.
9 +24V 8 CKU UP SIGNAL
KNEE SW.
10 0V 13 SH SW.
1 KNEE SW. 11 EARTH
B 2 OP SW.
2 0V 12 SAFETY SW. 7 PSU
12 0V
FOOT LIFTER 1 +12V +12V
1 +24V SAFETY SW. 6 PSD
C 2 A.F.L. SOL. MP 1 +5V +5V 11 0V
E 2 SAFETY SW.
3 0V

C
7. i 90M 4 ED :
A B

19 1
4 1
5 2
6 3
37 20
FOOT SWITCH ENCODER SEWING MACHINE

SEWING MACHINE
1 ---
FOOT SWITCH 2 +5V External
1 +12V 3 VHP variable
2 START 4 0V resister
3 VC 5 REV. SW.
A 4 KNEE SW. 6 NEEDLE UP SW.
5 0V 7 HP SW.
6 TRIMMER
8 STK SW.
9 DB2000
10 DB3000
11 SAFETY SW.
12 FAWU
13 PSD
14 BTL SW.
15 ---
16 +24V
17 +24V
B 18 ---
19 0V 0V
20 ---
21 ---
22 +12V 12V
23 ---
24 BTL LED O7
25 ---
26 +24V
27 WIPER SOL. MW
28 NCL SOL. O2
29 STK LED O6
30 STK SOL. O1
31 HP LED O5
32 HP SOL. O3
33 +24V
34 REV. SOL. MR
35 A.F.L. SOL. MP
36 TENSION SOL. ML
37 TRIMMER SOL. MT

D
:
7-Segment Display Characters Compare Table

: Arabic Numerals


Actual
0 1 2 3 4 5 6 7 8 9

Display

: English Alphabet


Actual
A B C D E F G H I J

Display


Actual
K L M N O P Q R S T

Display


Actual
U V W X Y Z

Display


Violators will be prosecuted

You might also like