TOLERANCES COMPARISON CHART BETWEEN IS : 7215, AWS D 1.

1 , 2010 , & MBMA

S.NO. DESCRIPTION IS: 7215 AWS D 1.1 MBMA

Upto 1000 mm = 1.0 mm


1 Offsetting Not Specified 3 mm Maximum
Over 1000 mm = 2.0 mm

1 % of flange width or
2 Flange warpage Shall not exceed 1.0 mm Not specified
6 mm Max.

0.015 b or maximum 4 mm
3 Out of squareness Not Specified 3 or 6 mm Maximum
( b = flange width )

Upto 900 mm = 3 mm
4 Depth + 3 mm & -2 mm upto 1800 mm = 5 mm 4.7 mm
Above 1800 mm = 8 mm

Upto 12 M = 3 mm
5 Length Not Specified 6 mm
Above 12 mm = 5 mm

6 Camber 5 mm Max. 1 mm / Meter 2 mm / Meter

0.001L or 10 mm Maximum
7 Sweep 1 mm / Meter 2 mm / Meter
( L= Length )

Upto 500 mm = 0.5 mm Upto 970 mm = 6.4 mm


8 Web Waviness 500 - 1000 mm = 1.0 mm Upto 1190 mm = 8.0 mm D/72 ( D = Depth of web )
Above 1000 mm = 2.0 mm Upto 1420 mm = 9.5 mm

9 Web to Flange Centre Out Not Specified 6 mm 6 mm

10 Hole location from End 1 mm Not Specified 3 mm

11 Hole to Hole Centre distance 1 mm Not Specified 1.5 mm

Note :- Please note that whereever IS tolerances are not specified, we will follow other relevant standard( AWS/ MBMA) tolereances .