SCHEDULE OF FINISHES

Walls
Footings 230x600mm in medium strength concrete to NBR standard and SANS
10400. Walls are built with 90mm bricks - heights as per plan. External walls to
26.5 plastered and painted with 50mm cavity between internal and external skins with 2.5
ROOF PITCH butterfly wire ties per square meter. All internal walls plastered with lime cement.
Brickforce in 4 layers over all openings, with precast concrete lintels to openings

1,594
greater than one metre.
300 300
Window-sills
External & Internal, smooth finished cement plaster.

4,144
DPC Roof Construction
Cement roof tiles @ 26.5 pitch on 38x38 SAP battens at maximum 320 centres on
PLASTER & prefabricated gangnail trusses at maximum 760 c/c, fixed to 114x38 wallplates and

2,550
PAINT anchored to brickwork with 30x2mmx1m hoop iron ties, built into walls for minimum of
NGL 600mm. SABS approved underlay to tiled roof. All roof timber to be minimum Grade
5 SA Pine TAN treated. All gable ends to be tied with hoop iron built into wall for
ELEVATION 1 minimum 600mm and up to two trusses away from gable to SANS 10400-L where
SCALE 1:100 applicable. Bracing as per A19 Engineer.
BATHRM LOUNGE
DPC DPC Eaves
400x200 250mic DPM
375mic DPM UNDER ALL WALLS 300mm Open eaves overhang with 225mmx10mm painted fibre cement fascias.
THICKENED
MINIMUM 150mm ABOVE FGL
FOUNDATION
600x230 600x230 Rainwater Disposal
SECTION A-A Alu. gutters with 75mm PVC downpipes as per plan.
SCALE 1:100
Ceilings
25mm Isoboard EPS ceiling on 38 x 38 SA Pine battens at 300mm spacing and 76mm
Rhino cornice with 155mm thick flexible polyester blanket(Isotherm).

Floors
Finished as per plan and/or client choice/building tender, on 25mm screed, on 80mm
concrete for ground storey, (as above) on 250 micron waterproof sheeting, on
compacted filling and sand blinding. All floor levels to be a minimum of 150mm
above FGL.

Doors & Windows


3 Windows top-hung aluminium, as per plan codes & elevations.
Note : Safety glass to window panes larger than 1sq.m or closer than 500mm from
5,700
230 90 230 ELEVATION 2 FFL to SANS 10137 and to comply to SANS 10400-N.
2,710 2,440 SCALE 1:100
Drainage
230 90 90 230 110mm Smooth uPVC Sewer pipe with minimum 1:60 fall with IL at minimum
1,710 910 2,440 450mm. 50mm 2way vent valve on start of one pipe sewer system. All sewer lines
passing under structure to comply to SANS 10400-PP24 (encase in sand or
2 1,130 900 3,670 concrete). All drainage to comply to SANS 10400-P.
W6
(900x1100) Electricals - as per building tender.
230
230

230

Position of Oostersee Electrical connection box on exterior wall to be determined on


1,200

site.

BEDRM 2
(900x1100)

BEDRM 1 NOTES:
2,020

(Carpet) Figured dimensions takes preference to scaled dimensions.


2,940

(Carpet)
2,620

W6

All relevant levels and dimensions to be verified on site prior to construction.


900
3,050

All work to comply to NBR, Local Bylaws and Municipal Regulations.


90

All levels to be determined on site and can/may be to adjusted to the descrepancy


B.I.C PLASTER & PAINT of the developer and his appointed builder. Developer to approve plan prior to
(600x900)

submission to council.
90

B.I.C All glazing to SANS 10137 & SANS 10400-N. Printed dimensions take prference over
ELEVATION 3
600
W3

BATH RM 4
2,700
90

scaled dimensions. All work to be carried out in strict accordence to NBR and local
(Tiles) SCALE 1:100
TV bylaws.
7,600

7,600

A A
2,020

HWC IN

Finishes in builders contract takes preference over finishes specified on plan.


ROOF
4,430

In case of discrepances the author of the plan should be contacted before


2,160

proceeding with any construction.


(1200x1200)
90

4,000
1,200
W2

LOUNGE
2,320

900

(Tiles)
KITCHEN
PD26
1,600

(Tiles)
230

1,000

WM
600
230

230

W5 W6
1,
15

(900x900) 480 (900x1100) PLASTER & PAINT


5

790 900 900 865 900 865


37 VAN DER STEL STREET P.O. BOX 1399 TEL: 021 906 6770
230
1,710
90
3,440
230 ELEVATION 4 KUILSRIVER
7579
KUILSRIVER
7580
FAX: 021 906 6775
EMAIL : nationhousing@mweb.co.za
SCALE 1:100
230 230 230 230
1,710 900 2,170
ELECTRICAL HOUSE PLAN- Type1-43sq.m DATE : AUG 2016
5,700
TELEPHONE POINT
PROPOSED NEW DWELLING DRAWING : 0816/MC

1 CEILING LIGHT POINT


FOR ............ ON ERF ..........., MONTCLAIR
PROJECT : NATION
SANS 10400-XA WATERPROOF LIGHT POINT HOUSING
MONTCLAIR SCALE : 1:100
FLOOR PLAN
SCALE 1:100
HWC DETAILS:
PIPING 15mm AND 22mm CLASS 1
COPPER TUBE
15 AMP PLUG POINT
15 AMP UNDERCOUNTER
AREA HOUSE : 43 sq.m HWC KWIKOT ECONO STD GALV. 150L MOUNT PLUG POINT
GEYSER.
LAGGING (R=1) ON ALL EXPOSED PIPES 15 AMP PLUG POINT 2000mm HIGH
WALLS EXT. 230 CAVITY
1200mm HIGH PC WALL INT. 90 x 190 mm DISTRIBUTION BOARD
W2= 1.2x1.2 = 1.44 sq.m
BUILDING LINES W3= 0.6x0.9 = 0.54 sq.m TV TV POINT
NOTE: W5 = 0.9 x 0.9 = 0.81 sq.m
RAINWATER CHANNEL W6= (0.9x1.1) x 3 = 2.97 sq.m
DP FFL ABOVE NGL TO BE STOVE CONNECTION
RAINWATER D.P. TOTAL = 5.76 sq.m
DETERMINED ON SITE. FLOOR AREA : 43 sq.m
110mm PVC SEWER
AT 1:40 GRADIENT
MINIMUM 150mm. FENESTRATION PERCENTAGE : 13.40 % BALL FITTINGS TO ALL LIGHT POINTS