(RECLOSER CONTROLLER APPLICATION - SURVEY FORM)


in lc:..

Ngi lin h: .

Chc danh: ..

S in thoi:
Vui lng ch thch vo ct Ghi ch, nu cc kin xut ca Qu v nm ngoi 4 ty chn c sn
Ghi ch

C ci t (Used)

C quan tm
(Interested)

Cn hun luyn
(Training needed)
(Remarks)

Cc tnh nng, ci t bo v
No
Functions of recloser controller

27kV 38kV

I Cc tnh nng, bo v ci t / Protection features


Qu dng pha, chm t c thi gian
1
(Phase, Earth Time Overcurrent)
Qu dng pha, chm t ct nhanh tc thi
2
(Phase, Earth Instantaneous Overcurrent)
Bo v chm t nhy cao ct nhanh tc thi
3
(Sensitive Earth Fault Instantaneous Overcurrent)
Bn gp trng hp ng dy trn khng b t, ri xung t m vn mang in cha?
4
(Have you had instances where a overhead line broke, fell to ground and remained energised?)
Bn c quan tm n tnh nng pht hin t dy trnh trng hp nguy him ny khng?
5
(Are you interested in Broken conductor detection to avoid this dangerous situation?)
Ct v kha khi dng cao (Pha & t)
(High current lock-out)
6
Tnh nng tnh nng kha bo v khi dng cao trnh trng hp ng li trn ng cp b li
(Are you interested in high current lockout protection control to avoid reclosing on cable faults?)

Bn c mch in no l ng dy cp ngm nhng li c mt phn ng dy trn khng c lp recloser khng?


7
(Do you have circuits which commence as an underground circuit but which also have an overhead portion with a recloser?)

Bn cn t ng li cho ng dy trn khng nhng nu mch in ang b cp ngun ngc li bn s khng mun t
8 ng li trn ng dy b li?
(You need reclosing for the overhead circuit but if the circuit is being backfed you do not want to autoreclose on a cable fault)

Tnh nng t ng ng lp li ca Recloser c kt hp vi hng dng in


9
(Would it be useful if you could associate Auto reclose function with the direction of current flow?)

Tnh nng c nhiu ch ci t vn hnh cho cc nhm bo v khc nhau hoc vi hng cng sut khc nhau khng?
10
(Are you interested in having different operator settings for different protection groups or different power flow direction?)
Qu dng, Chm t c hng
11
(Phase, Earth Directional)
Bo v dng th t nghch c thi gian, ct nhanh tc thi
12
(Negative Sequence Instantaneous, Time Overcurrent)
Bo v dng th t nghch c hng
13
(Negative Sequence Directional)
Bo v in p pha Thp/Cao
14
(Phase Under/Over Voltage)
T ng ng li khi in p tr v bnh thng
15
(Auto Reclose When Voltage Normal)
Bn c cn vn hnh sa thi ti trong thi im h thng c yu cu cao v cng sut khng?
16
(Do you have any responsibility for load shedding at times of high system demand?)
Bn c quan tm n tnh nng bo v tn s khng?
17
(Is Under Frequency protection of interest to you?)
Bo v tn s Thp/Cao
18
(Under/Over Frequency)
T ng ng li khi tn s t v bnh thng
19
(Auto Reclose When Frequency Normal)
Bo v chng mt pha
20
(Loss of Phase)
Kha chc nng ng khi ti mang in
21
(Live Load Blocking)
Tnh nng b qua dng xung kch (inrush current)
22
(Are you interested in Magnetizing Inrush Restraint protection?)
Bn c quan tm n tnh nng b qua dng xung kch sng hi bc 2 khng?
23
(Are you interested in Second Order Harmonic Inrush restrain protection?)

Bn c bao gi gp trng hp recloser b ct bi qu dng ti (khng c s c) sau khi ngun cung cp c phc hi
24 sau s c mt in khng?
(Have you ever had a recloser trip on overload current (no fault) after supply has been restored following an outage?)

Khi ng ti ngui
25
(Are you interested in Cold Load Pickup Control?)
Ci t nhiu nhm bo v
26
(Multiple Protection Setting Groups)
ng cong bo v cho php lp trnh ty bin
27
(Custom Programmable Protection Curves)
Bn c gp rt nhiu s c gy ra do st khng?
28
(Do you have a lot of non damage faults due to lightning?)
Bn c h thng c im trung tnh ni t qua khng tr bin p khng?
29
(Do you have impedance earthed transformer neutral points?)

Bn c quan tm n tnh nng ci t thi gian cht khc nhau (cho mi ln t ng li) cho s c pha v chm t khng?
30
(Are you interested in having different dead times (reclose times) for phase faults and earth faults?)

Bn c quan tm n kh nng ci t reclose bo m rng n s ct trc cu ch cho ln ct u tin nhng nu s c


vt qu gii hn ca cu ch th cu ch s t trong trng hp s c vnh cu?
31
(Are you interested in the ability to set your reclsoer to ensure that it trips before the fuse for the first trip but that if the fault is
beyond the fuse that the fuse will blow for a permanent fault?)
Bn c quan tm n tnh nng thit lp dng ci t cho tng ln ct khng
32
(Are you interetsted in Per trip threshold settings?)
Bn c s dng r le bo v dng a cm ng khng?
33
(Do you have induction disk protection relays?)
Bn c quan tm n vic bo m rng recloser c thit lp li (reset) nh a cm ng trong trng hp s c l khng
lin tc (intermittent) v c th lm cho my ct ct v s c khng lin tc khng nh mun?
34
(Are you interested in ensuring that your reclosers reset like an induction disk for cases where a fault is intermittent and would
otherwise potentially cause the station circuit breaker to trip for an intermittent fault beyond a recloser?)

Bn c quan tm n vic thit lp li (reset) ng cong bo v khng?


35
(Are you interested in protection reset curves?)
Trong li in ca bn c gn ngun my pht khng?
36
(Do you have embedded generating power stations in your MV network?)

Bn c quan tm n cc tnh nng bo v my pht chng hn nh kim tra ng b v tc thay i tn s khng


37
(Are you interested in generator protection facilities such as Synchro check and Rate of Change of Frequency?)

II Tnh nng t ng ha / Automation


Kim tra ng b li trc khi ng my ct
38
(Synchrocheck)
Chc nng cho php ngi dng t to cc logic mi cnh bo li, trng thi s c, iu khin my ct ... Cc n trng
thi v phm tt ty bin theo ngi s dng
39
(Custom Logic creation and implementation. Set Users-Logic to bring-out control signals, warning or indicate fault. All status
lamps and quick action keys are customisable)
Do you install reclosers in zone substations
40
Bn c dng reclosers cho trm khng?
Kh nng gim st v iu khin recloser t bng iu khin qua 16 ng vo / ra (ty bin)
41 (Would it be useful to have up to 16 fully configurable inputs and outputs to control other equipment or to know the status of
and control the recloser from a mimic panel in a substation)
S dng cc ng vo ra bo v thanh ci
42
(Would it be useful to use I/O for busbar protection schemes?)
iu khin t xa recloser
43
(Do you wish to remotely control your switchgear)
Giao thc truyn thng: IEC60870-5-101 / IEC60870-5-104
44
(What protocol would you use to control your switchgear? IEC60870-5-101? IEC60870-5-104?)
Bn ng vo / ra ty bin
45
(Would it be useful if the I/O map was completely user configurable?)
Bn c cn ty bin ng vo / ra khng?
46
(Would it be useful to create custom I/O points?)

III Tnh nng chn on / Diagnostic Features


Xc nh v tr s c - khong cch n s c
47
(Fault Location - distance to fault)
Chc nng gi lp dng / p s c - Waveform Generation
Chc nng gi lp dng v p cho php kim tra ci t bo v v thi gian tc ng?
48
(Would it be useful if the switchgear controller could simulate currents an voltages to allow for more simple checking of settings
and confirming correct tripping times?)
Chp dng sng
49
(Waveform Capture )
Kim tra pin
50
(On Load Battery Test)