Ngi lin h: .
Chc danh: ..
S in thoi:
Vui lng ch thch vo ct Ghi ch, nu cc kin xut ca Qu v nm ngoi 4 ty chn c sn
Ghi ch
C ci t (Used)
C quan tm
(Interested)
Cn hun luyn
(Training needed)
(Remarks)
Cc tnh nng, ci t bo v
No
Functions of recloser controller
27kV 38kV
Bn cn t ng li cho ng dy trn khng nhng nu mch in ang b cp ngun ngc li bn s khng mun t
8 ng li trn ng dy b li?
(You need reclosing for the overhead circuit but if the circuit is being backfed you do not want to autoreclose on a cable fault)
Tnh nng c nhiu ch ci t vn hnh cho cc nhm bo v khc nhau hoc vi hng cng sut khc nhau khng?
10
(Are you interested in having different operator settings for different protection groups or different power flow direction?)
Qu dng, Chm t c hng
11
(Phase, Earth Directional)
Bo v dng th t nghch c thi gian, ct nhanh tc thi
12
(Negative Sequence Instantaneous, Time Overcurrent)
Bo v dng th t nghch c hng
13
(Negative Sequence Directional)
Bo v in p pha Thp/Cao
14
(Phase Under/Over Voltage)
T ng ng li khi in p tr v bnh thng
15
(Auto Reclose When Voltage Normal)
Bn c cn vn hnh sa thi ti trong thi im h thng c yu cu cao v cng sut khng?
16
(Do you have any responsibility for load shedding at times of high system demand?)
Bn c quan tm n tnh nng bo v tn s khng?
17
(Is Under Frequency protection of interest to you?)
Bo v tn s Thp/Cao
18
(Under/Over Frequency)
T ng ng li khi tn s t v bnh thng
19
(Auto Reclose When Frequency Normal)
Bo v chng mt pha
20
(Loss of Phase)
Kha chc nng ng khi ti mang in
21
(Live Load Blocking)
Tnh nng b qua dng xung kch (inrush current)
22
(Are you interested in Magnetizing Inrush Restraint protection?)
Bn c quan tm n tnh nng b qua dng xung kch sng hi bc 2 khng?
23
(Are you interested in Second Order Harmonic Inrush restrain protection?)
Bn c bao gi gp trng hp recloser b ct bi qu dng ti (khng c s c) sau khi ngun cung cp c phc hi
24 sau s c mt in khng?
(Have you ever had a recloser trip on overload current (no fault) after supply has been restored following an outage?)
Khi ng ti ngui
25
(Are you interested in Cold Load Pickup Control?)
Ci t nhiu nhm bo v
26
(Multiple Protection Setting Groups)
ng cong bo v cho php lp trnh ty bin
27
(Custom Programmable Protection Curves)
Bn c gp rt nhiu s c gy ra do st khng?
28
(Do you have a lot of non damage faults due to lightning?)
Bn c h thng c im trung tnh ni t qua khng tr bin p khng?
29
(Do you have impedance earthed transformer neutral points?)
Bn c quan tm n tnh nng ci t thi gian cht khc nhau (cho mi ln t ng li) cho s c pha v chm t khng?
30
(Are you interested in having different dead times (reclose times) for phase faults and earth faults?)