You are on page 1of 31

Internal Only

UMTS SDR
Commissioning Guide
GU Product Support Dept.
Internal Only

Purpose

You are expected to master the following


knowledge after this course:
Know how to make preparations for UMTS SDR
commissioning
Get familiar with data configuration of UMTS

SDR
Get familiar with UMTS SDR version

management
Know the standard workflow of commissioning

Note: the interfaces may be different for different


software versions.

2012/6/14 2
Internal Only

Contents

Introduction

Preparations

Power-on Check

Data Configuration and Version Management

Test after Commissioning


Internal Only

UMTS SDR commissioning procedure

Start Configure data


offline

Preparations
No need to Need to
upgrade upgrade
NodeB version NodeB version

Power on/off
equipment Upgrade LMT
Online logon
version

Install LMT
Configure all
tables

Service Iub interface


End
verification integration
Internal Only

General cares in commissioning


1. Anti-static protection: please wear anti-static wrist strap
when checking equipment.
2. Please follow the instructions described in engineering
specifications to perform operations on modules. For
redundant modules, please pack them with anti-static bags.
3. The engineers participating UMTS SDR commissioning
must get the following documents at least
ZXSDR ****** Installation Manual.pdf
ZXSDR ****** O&M Manual.pdf
ZXSDR ****** Commissioning and Configuration Manual.pdf
ZXSDR ****** Hardware Manual.pdf
ZXSDR ****** Technical Manual.pdf
****** represents SDR type, such as B8200+R8840, BS8800
and BS8900.
Internal Only

Contents

Introduction

Preparations

Power-on Check

Data Configuration and Version Management

Test after Commissioning


Internal Only

UMTS SDR commissioning preparation flow

Get information (sites for commissioning


and contacts)

Get information about equipment


configuration and networking

Prepare spare parts, tools and technical


documents required for commissioning

Estimated time

Contact the person in charge to decide


when to start
Internal Only

Preparations for UMTS SDR Commissioning

Preparing tools

Prepare software

Prepare documents

Data configuration
Internal Only

UMTS SDR commissioning preparations - tools

PC configuration requirements:
CPU main frequency: PIII 800 or higher
Memory > 256MB;
Hard disk > 10GB;
OS: Windows XP professional

Others
Screwdriver, power socket and
multi-meter
Internal Only

UMTS SDR commissioning preparations - software

LMT software match to the SDR version

SDR software package


Internal Only

UMTS SDR commissioning preparations - documents

Installation acceptance report (ensure the


installation has been completed and passed
the acceptance)

Unpacking acceptance report (ensure


boards and all hardware equipment are
available
Internal Only

UMTS SDR commissioning preparations - data

Node B configuration file, for example:


SDR No-IP S101 B1001.xml
Internal Only

Contents

Introduction

Preparations

Power-on Check

Data Configuration and Version Management

Test after Commissioning


Internal Only

Checking connection
of LMT
Checking cable

Power on/off
connection

equipment
Checking connection

End
of Iub interface
Checking connection
of racks
Power-on procedure

Check the internal


Checking boards

Checking input
power supply
jumper switch of other
boards
Start

Check the internal


jumper switch of the
SA
Internal Only

UMTS SDR power-on check


Checking boards
Checking input power supply

Checking cable connections

Power-on the equipment


Internal Only

Power-on procedure checking boards


Check whether the SDR has been configured with the
right quantity of boards as planned.
Check whether boards have been inserted into the
correct slots.
Check the internal jumper DIP switch of the SA board

X5 jumper status [3, 2] Mode

[open circuit, open circuit] Uplink short cable, downlink short cable

[short circuit, short circuit] Uplink long cable, downlink long cable

[open circuit, short circuit] Uplink short cable, downlink long cable

[short circuit, open circuit] Uplink long cable, downlink short cable
Internal Only

Power-on procedure checking boards


X5 jumper status [1, 0] E1/T1 mode

[short circuit, short circuit] Reserved

[short circuit, open circuit] T1, 100

[open circuit, short circuit] E1, 120

[open circuit, open circuit] E1, 75 (by default)

X6 jumper status [2, 1, 0] BBU Cabinet No.


[open circuit, open circuit, open circuit] 0
[open circuit, open circuit, short circuit] 1
[open circuit, short circuit, open circuit] 2
[open circuit, short circuit, short circuit] 3
[short circuit, open circuit, open circuit] 4
[short circuit, open circuit, short circuit] 5
[short circuit, short circuit, open circuit] 6
[short circuit, short circuit, short circuit] 7
Internal Only

Power-on procedure check input power supply

Check whether the polarities of the power supply are


correctly connected.

Check whether the input power range of the DC power


cabinet is within the range of - 40VDC - -57VDC.

If 220V-AC power supply is adopted, B8200 must be


used together with the PSU. Check whether the single-
phase voltage is within the range of 200V AC 240V AC,
and whether the frequency is span is within the range of
47 Hz 53 Hz.
Internal Only

Power-on procedure check cable connection


If fibers are used for the Iub interface connection, check whether
fibers are correctly connected from RNC and B8200 to the CC board.

If E1 cables are used for the Iub interface connection, check whether
the E1 cables between the DDF and B8200 are correctly connected.

If FE cables are used for the Iub interface connection, check whether
the FE cables between the Switch and B8200 are correctly connected.

Check whether the fibers between the B8200 FS board and RRU are
correctly connected

Check whether the LMT port on the CC board is normal. Connect to


the LMT port on the CC board and the PC debugging port with cables

Check whether cables to dry contacts, the 232 serial port and the 485
serial port are correctly connected.
Internal Only

Power-on procedure power on/off BBU

Power-on steps
Check whether the equipment is grounded
Plug out all of the boards of B8200 except the PM.

Set the switch connecting B8200 in the DC power cabinet to ON position.


Check whether the RUN LED on the PM board flashes at the frequency of
1Hz, and whether the ALM LED is OFF.

Check whether the RUN LED on the FA board flashes at the frequency of
1Hz, and whether the ALM LED is OFF. After the PM is powered on
normally and the fan runs normally, insert the CC, BPC, SA and FS boards
to see whether they are powered on normally, and whether every LED is in
normal status.

Power-off steps
Set the switch connecting B8200 in the DC power cabinet to OFF position.
Internal Only

Power-on procedure power-on/off RSU


Power-on steps
Check whether the equipment is grounded
After confirming the power cables are correctly connected, set the
switch connecting R8840 in the DC power cabinet to ON position.
Observe whether the LED status is normal.
If there is an indoor lightning protection box, set the switch connecting
R8840 in the indoor lightning protection box to ON position. Observe
whether the LED status is normal.
If there is a power distribution box providing multiple DC-outputs, set
the switch connecting R8840 in that lightning protection box to ON
position. Observe whether the LED status is normal.
Power-off steps
If there is an indoor lightning protection box, then set the
corresponding switch in the indoor lightning protection box to OFF
position.
If there is no indoor lightning protection box, then set the
corresponding switch in the DC power cabinet to OFF position.
Internal Only

Power-on procedure power-on/off RSU

Power-on step
Switch on the power supply of the RSU

Power off step


Switch off the power supply of the RSU
Internal Only

Contents

Introduction

Preparations

Power-on Check

Data Configuration and Version Management

Test after Commissioning


Internal Only

Import UMTS SDR data configuration

Start the PC LMT software (installed already)

When EOMS is starting, select data


configuration of the SDR and import them
(the file is ready, *.xml)
Internal Only

UMTS SDR Version Management


Import the version and download it

Activate the version


Internal Only

UMTS SDR version management-import and download


Internal Only

UMTS SDR version management - activate


Internal Only

Contents

Introduction

Preparations

Power-on Check

Data Configuration and Version Management

Test after Commissioning


Internal Only

UMTS SDR service test


Speech service

Data service

Other services

For test items, please refer to ZXSDR ****** Test


Guide
Internal Only

Review

1. Commissioning procedure
2. Commissioning preparations
3. How to configure and manage
version information

4. Service test
5. Q&A
Internal Only

You might also like