You are on page 1of 16

BILL OF ENEGINEERING MEASUREMENT AND EVALUATION

PROJECT:

SUGGESTED
OR
APPROVED
S/NO DESCRIPTION EQUAL QTY UNIT RATE TOTAL COST
LIGHTING POINTS AND
A FITTINGS

Round 60mm recessed low


voltage downlight complete
with 50W dichroic mirror lamp
with adjustable lamp position.
(including transformer)
1 Brass/White effect Aurora

Round 185mm recessed


downlight complete with
2X20W compact fluorescent
2 fittings Aurora 0
Recessed 600X600mm, 4X18W
3 flourescent fittings Benneth 0
Surface mounted 1X40W
flourescent fitting with opal
4 glass diffuser Benneth 0
Surface mounted 2X40W
flourescent fittings with opal
5 prismatic diffuser Benneth 0

connection point for toilet


extractor fan (to be linked
controlled via toilet light
6 switch) 0
Splashproof surface mounted
fittings with compact
7 flourescent Astra 0
8 600mm, 18W mirror lights Astra 0

Decorative wall mounted


fittings with compact
flourescent lamp for the stair
9 landing Astra 0

Decorative surface mounted


fittings with compact
flourescent lamp for the stair
10 hall and lift lobby area Astra 0
Ceiling mounted
maintained/non maintained 3-
hour duration emergency exit
sign for 8W T5 (T16) linear
flourescent lamps with
manual/self
testing/capabilities and strong
durable construction with
11 pictogram Benneth 0

wall mounted maintained/non


maintained 3-hour duration
emergency exit sign for 8W T5
(T16) linear flourescent lamps
with manual/self
testing/capabilities and strong
durable construction with
12 pictogram Benneth 0

Economical high performance,


self contained surface IP65
emergency lighting of 3-hour
duration with 8W T16 linear
flourescent lamp with
manual/self addressable
13 testing capabilities Benneth 0

Decorative weatherproof
ceiling mounted lighting fitting
14 with compact flourescent lamp Benneth 0
Decorative up/down light with
15 2X35W dichroic lamp Spazio 0

Cabling all lighting point in


loop-in system using
2X1.5mmsq single core PVC
insulated copper cable (red &
black) (cost of wiring to be per
16 point) KabelMetal 0

20mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
17 be per point) KabelMetal 0
Bulkhead fittings with 18W
compact flourescent on the
18 perimeter fence Spazio 0
Cabling all lighting point in
loop-in system using
3X2.5mmsq single core PVC
insulated copper cable (red,
black & green) (cost of wiring
19 to be per point) KabelMetal 0

20mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
20 be per point) KabelMetal 0

4.5mtr aluminium or steel pole


light fittings with 250W
mercury vapour lamp with
21 pole 0
22 Bollard fittings Spazio 0

Cabling all lighting point in


loop-in system using 4mmsq 3-
core PVC/PVC insulated copper
cable (red, black & green )(cost
23 of wiring to be per point) KabelMetal 0

25mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
24 be per point) KabelMetal 0
SUB-TOTAL (A) 0

B POWER POINTS AND SOCKETS


25 13A Switch Socket Outlet ABB 0
26 2X13A switch socket outlet ABB 0
27 13A Switch UPS Socket Outlet ABB 0
2X13A switch UPS socket
28 outlet ABB 0

Cabling all socket in loop-in


system using 3X2.4mmsq 3-
core PVC/PVC insulated copper
cable (red, black & green )(cost
29 of wiring to be per point) KabelMetal 0

20mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
30 be per point) KabelMetal 0
31 15A socket outlet Clipsal 0
20A double pole switch for
32 Airconditioning unit Clipsal 0
Electrichand dryer with
automatic start and stop
including 20A DP switch with
33 neon light indicator Airdri 0

Cabling to be radial circuit


system using 3X4mmsq single
core PVC insulated copper
cable (red, black and green)
34 (cost of wiring to be per point) KabelMetal 0

20mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
35 be per point) KabelMetal 0

Cabling to be radial circuit


system using 3X6mmsq single
core PVC insulated copper
cable (red, black and green)
36 (cost of wiring to be per point) KabelMetal 0

25mm dia. PVC conduit pipe,


75X75mm galvanizes switch
box and other conduit
accessories. (cost of wiring to
37 be per point) UPS KabelMetal 0
SUB-TOTAL (B) 0
C SWITCHES
38 One-gang one way switch ABB 0
39 Two-gang one way switch ABB 0
40 Two-gang two way switch ABB 0
41 Two-gang dimmer switch ABB 0
One-gang two way
42 intermediate switch ABB 0
43 One-gang two way switch ABB 0
SUB-TOTAL (C) 0
SUPPLY CABLES, GEAR
SWITCHES AND DISTRIBUTION
D BOARDS
10mmsq, 4-core PVC/SWA/PVC
cable to the lighting kiosk and
44 gate house KabelMetal 0

16mmsq, 4-core PVC/SWA/PVC


45 cable to the DBs KabelMetal 0

Allow for PVC sleeves (100mm,


75mm and 50mm dia) for the
46 cables Lot Sum 0
47 6mmsq PVC earth cable KabelMetal 0
48 10mmsq PVC earth cable KabelMetal 0
4-way TP&N 63A D/B with
49 ELCB ABB 0
8-way TP&N 63A D/B with
50 ELCB ABB 0
6-way 60A TP&N 63A D/B with
51 ELCB for UPS distribution ABB 0

Misc: Items necessary for a


complete installation, but
omitted to be listed & priced
here Lot 0
SUB-TOTAL (D) 0
E EQUIPMENT

650va online(UPS)power
supply system for CCTV
53 monitor in thegate house: Mercury 0
5kva online(UPS) single phase
54 power supply system Leibert 0
SUB-TOTAL (E) 0

Transformer installation and


F PHCN connection

Metering, Statutory and


connection cherges to local
electricity supply autority
(Actual costto be determined
56 by PHCN) 0

600A Bus-bar for distribution


57 of power 0

200amps TP&N Nepa Back-up


58 (with ABB 4-pole MCCB) 0
SUB-TOTAL (F) 0
Main MV panel, Change-over
and Nepa/Generator Mains
G supply cables

35mmsq single-core
PVC/SWA/PVC cable (from the
generator and transformer to
the MV panel via the change
59 over KabelMetal 0

Light control kiosk comprising


of contactors, 32A cut-out, 20A
MCB outgoing, photoelectric
60 switches for external areas WAECO 0
200A Auto transfer panel with
over-ride switch button and
61 MCCB Merlin 0

MV switchboard comprising
ammeter, voltmeter, frequency
meter, selector switch,
indicator lamp and in
particular the following with
one 3-phase check meter for
all the outgoing services (check
62 the schematic diagram) Merlin 0
a 200A TP&N incomer 0
b 100A TP&N MCCB outgoing 0
63A TP&N MCCB outgoing for
c lighting kiosk 0
d 63A TP&N MCCB spare 0
Cable lugs, cable glands,
63 insulation tapes and others 0

Allow for proper earthing


system with all earthing
acessories and 1no earth pit
linked to the light protection
64 system 0

Misc: Items necessary for a


complete installation, but
omitted to be listed & priced
65 here 0
SUB-TOTAL (G) 0
DSTV/VIDEO DISTRIBUTION
H NETWORK

0.9m Fibre-glass satellite dish


with low Noise Block (LNB),
offset feedhorn plus steel
stand for KU-band DSTV and
66 decoder 0
67 18ob Signal Amplifier 0
68 6-Way passive splitter 0

Recessed flushed mounted


satellite TV signal outlet
69 connected in star circuit 0

Interconnection cables for


satellite/antenna system:
Cabling to be star connection
using RG6 75ohms co-axial
70 cable (cost to be per point) 0
25mm dia. PVC conduit pipe,
75X75mm gavanised switch
box and other conduit
accessories (cost to be per
71 point) 0
SUB-TOTAL (H) 0
LIGHTING PROTECTION
I SYSTEM

TS 3.40 prevention Non-


reactive Air terminal lightning
arrestor complete with air
terminal base and all other
mounting fixtures, accessories
72 & earthing 0
Elevation pole with bracket
73 and clamping devices 0
74 25mm Copper tape 0
75 600X600mm Earth mat 0
76 Earth Copper rod 0
Allow copper clamps, nail,
clips, materials and 1no test
77 point 0
SUB-TOTAL (I) 0
78 As built drawings

79 Preliminaries and Contigencies


SUMMARY
LIGHTING POINTS AND
A FITTINGS

B POWER POINTS AND SOCKETS


C SWITCHES
SUPPLY CABLES, GEAR
SWITCHES AND DISTRIBUTION
D BOARDS
E EQUIPMENT
Transformer installation and
F PHCN connection
Main MV panel, Change-over
and Nepa/Generator Mains
G supply cables
DSTV/VIDEO DISTRIBUTION
H NETWORK
LIGHTING PROTECTION
I SYSTEM
BILL OF ENEGINEERING MEASUREMENT AND EVALUATION
PROJECT:
TOTAL
S/NO DESCRIPTION QTY UNIT RATE COST
A SANITARY FIXTURES

Advent close couple


washdown W.C suite in
vitreous china with seat,
cover, connector, closed
couple cistern and
fittings Twyford or any
1 approved equal -

STD close couple


washdown W.C suite
with horizontal outlet in
vitreous china with seat,
cover, connecter, classic
cistern and fittings.
Twyford or any approved
2 equal -

Rhapsody 850 (oval)


countertop in vitreous
china 2 topholes, grid
waste. Twyford or any
3 approved equal -
Wash basin wall
4 mounted for gate house -
Shower tray in vitreous
5 china for gate house -

Vectra stainless steel


sink double bowl single
drain for kitchen.
Twyford or any approved
6 equal -
SUB-TOTAL (A) -
B ACCESSORIES

Bevel edged mirror with


chrome plated screws.
Size: 610X460mm
Twyford or any approved
1 equal -

Twyford wall mounted


toilet roll holder or any
2 approved equal -

Twyford towel rail


(chrome plated)
complete with exposed
screws or approved
3 equal -
Soap dispenser Twyford
4 or any approved equal -
other items not listed
above to be listed below
5 or priced -
SUB-TOTAL B -
WATER STORAGE
C TANK/PUMPS

Duplicate booster pumps


assembly with
associated delay timer
and switches (1duty 1
standby) Lowara m3/h,
30m head, 1.5hp with all
necessary accessories
mounted on a common
1 base frame -
Cut-in cut-out switch for
2 ground tank -
Float switch for
3 underground tank -
Electrical wiring for
4 switches and starters -
Starter for pumps
5 (Telemechanique) -
other items not listed
above to be listed below
6 or priced -
SUB-TOTAL C -
D FIRE FIGHTING SYSTEM
FIRE HOSE REEL
1 50mm dia GI supply pipe -
2 25mm dia GI supply pipe -
3 19mm dia GI supply pipe -
4 50mm dia Tee -
5 50mm dia Bend -
50mmX25mm dia
6 reducer -
7 25mmX19mm dia Tee -
8 50mmX25mm dia Tee -
9 50mm dia elbow -
10 25mmX19mm dia Elbow -
11 19mm dia elbow -

12 25mm dia air relief valve -


Lowara hydropolus
pressure booster
(comprises duty/standby
pumps) prefabricated
pump station with time
delay relay, pressure
switch and diaphram
13 tank. 1.5L/s at 3bar -
Fire hose reel cabinet
14 (950X950mm) -

Fire hose reel with


control nozzle jet/spray
of 4.80mm, 30m long
and 19mm inter
connecting pipework.
Augus or Macron or any
15 approved equal -
other items not listed
above to be listed below
16 or priced -
SUB-TOTAL (D) -
E FIRE EXTINGUISHER

Dry chemical powder


fire extinguisher 6kg
with visible gauge and all
necessary accessories.
Angus or any approved
1 equal -

Water/CO2 fire
extinguisher 6kg with
visible gauge and all
necessary accessories.
2 Angus or approved equal -

Mobile fire extinguisher


50kg ABC powder. Angus
3 or any approved equal -
SUB-TOTAL (E) -

RAIN WATER DRAINAGE


F PIPES AND FIXTURES
100mm dia PVC fulbora
1 outlet -
2 100mm dia PVC pipe -
100mm dia PVC bend
3 (long radius) -
4 100mm dia PVC bend -
Tangit, gum, bracket
amd screws etc.
600X600mm manhole
5 heavy duty -
Cast iron cover with
standard steel gratings
6 for storm drain -
other items not listed
above to be listed below
7 or priced -
SUB-TOTAL (F) -
SOIL WASTE/VENT PIPES
G AND FITTINGS
150mm PVC pipe
1 (3.2mm thick) -
100mm PVC pipe
2 (3.2mm thick) -
50mm PVC pipe (3.2mm
3 thick) -
4 100mm dia PVC tee -
5 50mm dia PVC tee -
100mm dia PVC bend
6 (90) -
7 50mm dia PVC bend -
50X32mm dia PVC
8 reducer -
9 100X50mm reducer -
10 50X38mm PVC reducer -
38mm bottle trap
11 (Chrome plated) -
32mm bottle trap
12 (Chrome plated) -
32mm waste to trap
13 connector -
38mm waste to trap
14 connector -

600X600mm manhole
with removable concrete
15 cover (by others) -
100mm dia PVC vent
16 cowl -
Tangit, gum, brackets
17 and screws -
100mm dia PVC pan
18 connector -
19 50mm dia PVC plug -
20 100mm plug -
other items not listed
above to be listed below
21 or priced -
SUB-TOTAL (G) -
COLD WATER SUPPLY
H PIPES AND FITTING
1 40mm dia pipe (copper) -
2 32mm dia pipe (copper) -
3 25mm dia pipe (copper) -
4 19mm dia pipe (copper) -
5 13mm dia pipe (copper) -
40X32mm dia Tee
6 (copper) -
7 32mm dia Tee (copper) -
32X25mm dia Tee
8 (copper) -
9 25mm dia Tee (copper) -
10 19mm dia Tee (copper) -
19X25mm dia Tee
11 (copper) -
12 40mm dia Elbow -
13 32mm dia Elbow -
14 25mm dia Elbow -
15 19mm dia Elbow -
16 13mm dia Elbow -
17 40X32mm dia Elbow -
18 32X25mm dia Elbow -
19 19X13mm dia Elbow -
20 19X13mm dia Tee -
21 40mm straight coupling -
22 32mm straight coupling -
23 25mm straight coupling -
24 19mm straight coupling -
25 13mm straight coupling -
40mm male iron to
26 copper -
32mm male iron to
27 copper -
25mm male iron to
28 copper -
19mm male iron to
29 copper -
13mm male iron to
30 copper -
40mm dia gate valve
31 (England) -
32mm dia gate valve
32 (England) -
25mm dia gate valve
33 (England) -
32mm dia ball valve
34 (England) -
40mm dia Non return
35 valve -
13mm dia chrome
36 plated angle valve -
37 32X25mm reducer -
38 25X19mm reducer -
39 13mm dia UPVC sockets -
40 External Bib Taps -
Escutcheeon plate for
41 angle valve -

Provide insulation for


copper pipes laid
underground or under-
42 slab -
other items not listed
above to be listed below
43 or priced -
SUB-TOTAL (H) -
DIESEL TANK
I INSTALLATION

Diesel storage tank


fabricated from 6mm
thick mild steel plates
with circular manhole,
vent, level indicator,
strapping etc. Capacity:
1 22,000 litres -

Day diesel tank


fabricated from 4mm
thick mild steel plate
with circular manhole.
Capacity 1000litres
installed in generator
house with electric float
switch for automatic
2 filling -
Manhole cover and
frame made from 5mm
3 thick plate -
4 Pipe fittings -

Diesel oil pump with


electric switch board
manual/automatic 1.5hp
with appropriate motor
rating. Stork or any
5 approved equal -
Water/Fuel seprator
Dual type or any
6 approved equal -

Fuel filter, velcron model


VF with 1 micron
catridge rated at 5L/sec
7 pressure gauge. -
8 Stainer -
50mm dia GI discharge
9 pipe to diesel -
40mm dia GI to diesel
10 day tank/gen -
Crane to be hired for
underground tank
11 installation -
other items not listed
above to be listed below
12 or priced -
SUB-TOTAL (I) -

SUMMARY
A SANITARY FIXTURES
B ACCESSORIES
WATER STORAGE
C TANK/PUMPS
D FIRE FIGHTING SYSTEM
E FIRE EXTINGUISHER

RAIN WATER DRAINAGE


F PIPES AND FIXTURES
SOIL WASTE/VENT PIPES
G AND FITTINGS
COLD WATER SUPPLY
H PIPES AND FITTING
DIESEL TANK
I INSTALLATION
TOTAL
GRAND TOTAL
BILL OF ENGINEERING MEASUREMENT AND EVALUATION
PROJECT TITLE:
S/NO DESCRIPTION QYT UNIT RATE TOTAL
INTERNAL PLUMBING INSTALLATION

Sanitary fixtures shall include supply and


fix completely the following, including all
joints to cold water supply and discharge
1 pipes with traps

Low level water closet suite with s-trap of


white "Twyford" type or other equal and
approved comprising pan, plastic cover,
flushing cistern, flush bend and concealed
fixing brackets including plugging and
A screwing pan and bracket

400X365mm Twyford type or other equal


and approved lavatory wash hand basin
complete with pair 13mm pillar tap, 32mm
waste fitting with plug chain and stay,
32mm trap and pair cantilever bracket
B including plugging and screwing brackets

Armitage shank ceramic laboratory through


540 X 450 X370mm deep complete with
C top head and water fitting

D Brick model B-6699 Toilet roll holder


E Automatic soap dispenser

Pilkington mirror or approved equal with


F clip and screwed for mounting to wall

TO COLLECTION

WASTE/SANITARY PIPE WORKS UNPLASTICATED


PVC PIPES TO BS4515 WITH SOLVENT WELDED
2 JOINT
A 100mm diameter pipe
B 100mm diameter bend
C 100mm diameter Y junction
D 100mm diameter Tee
E 100mm diameter pan connector
F 32mm diameter pipe
G 32mm diameter bend
H 32mm diameter Y junction
J 32mm diameter Tee
K 32mm diameter floor drain

TO COLLECTION

3 RAIN WATER INSTALLATION

Unplastized pvc rain water pipes and


fittings to BS 4514 with ring seal joints
100mm diameter rain pipes bedded in
A concrete column
B 100mm diameter bend
Fulbora cast iron roof and balcony outlet
complete with grating including building
C into concrete
TO COLLECTION

COLD WATER SUPPLY PIPES, TIGER


PRESSURE PIPES TO BS 4514 WITH
4 SOLVENT WELDED JOINTS
A 19mm diameter pipe
B 19mm diameter bend
C 19mm diameter Tee
D 19X19X13mm reducing Tee
E 13mm diameter pipe
F 13mm diameter bend
G 13mm diameter Tee
H 13mm diameter flexible connector
J 19mm diameter non-return valve
K 19mm diameter gate valve
L 13mm diameter gate valve
TO COLLECTION

INTERNAL FIRE FIGHTING INSTALLATION


4 HOSE REEL SYSTEM
A 50mm Diameter pipe
B 50mm Diameter bend
C 50x50x38mm Reducer Tee
38mm cold water supply hose reel bedded
D in wall
E 25mm Diam. Landing valve

Recessed Fire Hose Reel as manufactured


by 'NORSEN TYPE 'S' or other equal and
approved designed to withstand a pressure
of 1035KN/m2 consisting of steel plate
,nylon reel bearing,actual axle and water
ways,plated nylon roller guides brackets
,screw down brass stop valve to
B.S.1010,nylon off jet spray action nozzle
and 19mm diameter bore 30m long rubber
reel hose ,all housed in cabinet with full
length recessed and hand grip in the
F door,complete with landing valve outlet
6kg all purpose carbondioxide fire
G extinguisher[ANGUS]

9kg ABC Multipurpose dry powder fire


extinguisher complete with charge and wall
mounted brackets fixed 1050mm above
E floor level