11.1
(DRAWING) (TECHNICAL SPECIFICATION)
(BILL OF QUANTITY)
11.1.1
Lightning Arrester
11.1.2
11.1.3
11.2
11.2.1
-The Provincial Electricity Authoritys code (PEA)
- The Metropolitan Electricity Authoritys code (MEA)
- Engineering Institute of Thailand (EIT)
- The National Electric Code (NEC)
- National Fire Protection Association (NFPA)
- International Electrotechnical Commission (IEC)
- British Standard Specification (BS)
- American Society for Testing of Materials (ASTM)
.1
( 2) -1
1 :
11.3
11.3.1
(1)
(2)
11.3.2
(1)
30
(2)
11.3.3
11.3.4
(1)
(Operation Manual)
(2)
(3)
.1
( 2) -2
1 :
11.3.5
11.4
11.4.1
11.4.2
11.4.3
.1
( 2) -3
1 :
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
3
11.5 (Servicing)
.1
( 2) -4
1 :
11.6 (Guarantee)
1
11.7
11.7.1
22 3 3
IEC, ANSI,
NEMA, UL, DIN, TIS
11.7.1.1 Lightning Arresters
(1) Lightning arresters IEC
(2)
- Type :Single-pole, outdoor, station valve type.
- Rated voltage :
- Rated frequency : 50 Hz.
- Impulse withstand voltage (BIL) : 150 kV
- Interrupting current : 5 kA
11.7.1.2
(1)
IEC
(2)
- Type : Single-Core, outdoor, vertical mounted type.
- Rated voltage :
- Rated frequency : 50 Hz.
- Impulse withstand : 125 kV
Voltage (BIL)
- Rated current Fuse Link :
- Interrupting current :10 kA (Asym. rms.)
11.7.1.3
(1) XLPE XLPE
(Space Aerial Cable; SAC) IEC 60502 .2341-2550
(2) XLPE 3.3 kV.
3.6/6(7.2) kV CV, 6/10(12) kV CV,
.1
( 2) -5
1 :
11.7.1.5
Spun
11.7.1.6
2 (Pin Type) (Suspension Type)
EEI-NEMA Class56-2 Voltage
Rating 22 kV EEI-NEMA
Class 52-1
11.7.1.7
11.7.1.8
(Messenger
Wire) 50
.1
( 2) -6
1 :
11.7.2 (Transformer)
11.7.2.1
.384-
2543 IEC60076
11.7.2.2
(1) :Oil Immerse, Outdoor Type
(2) : (ONAN)
(3) :3
(4) Rated Power Output :
(5) Rated Frequency :50 Hz
(6) Rated Voltage & Windings Connection
:22 33 kV. (.) 24 kV. (.) delta
:(a) 400/230V. (.) 416/240V. (.) wye
(b) 3.3 kV. 6.9 kV. (Medium Voltage)
(7) Vector Group:Dyn 11
(8) HV Off Load Tap Changer: 2 x 2.5 % of rated Load Full kVA. Capacity
(9) Voltage Regulation : 1.5 % Full Capacity Power Factor
At Full load 1.0
(10) Impedance Voltage :4% ( 630 kVA.)
(at 75 C) 6% ( 630 kVA.-2500 kVA.)
7% ( 3000 kVA.- 6000 kVA.)
(11)
:
:
(12) Impulse withstand Voltage
:125 kV
11.7.2.3
(1) /
Weather-resistant Coats
.1
( 2) -7
1 :
11.7.3
/
IEC, DIN, NEMA, BS, ASTM, JIS
11.7.3.1
(1) 60227 IEC 01
.11-2553 PVC
.1
( 2) -8
1 :
.1
( 2) -9
1 :
11.7.3.7
(1) 1.2
100
1.5
(2)
2.4
(3)
(4) (Galvanized Steel)
(5) Floor Box Box
11.7.3.8
(1) 220 , 50
(2) Starter Fluorescent VDE
JIS NEMA
(3) Galvanized
(4)
0.8
(5) 70
1.0
(6)
11.7.3.9
(1) Day Light
(2) . 236-
2533
(3) .956-
2533 .1955-2542
(4) T5
: T5 5 (.)
(5) LED .
ISO9001
11.7.3.10 (Ballast)
(1) .23-2521
.1
( 2) -10
1 :
(2) .183-2528
(3) T5
: T5 5
(.) .1506-2541
11.7.3.11
(1) . 824-2531
(2) 15 250
(3) /
(4)
()
11.7.3.12
(1) . 166-2549
(2) 10 250 (Grounding Duplex
Universal Receptacles)
(3)
(4)
10
250 (Grounding Duplex Universal Receptacles)
11.7.3.13
(1)
(2) (Weatherproof)
11.7.3.14 (PANELBOARD) Consumer Unit
(1) (PANELBOARD) Consumer Unit IEC
(2) 3 4
400/230 () 416/240
()
Epoxy Powder Coated 1.2 .. Grounding
(3) Consumer Unit 1 2 220
.1
( 2) -11
1 :
(4)
3 1 2
3
(5) Instantaneous Short Circuit Trip, Inverse Time Over
current Trip 40
(6) (PANELBOARD)
Molded Case Circuit Breaker 3 Pole
(7) Consumer Unit Miniature Circuit Breaker 2 Pole
.1
( 2) -12
1 :
(2) 3.0
Compartment 2.0
(3)
(4)
(5) Zinc Phosphate Etching Primer ICI
125
30 2
(Powder Coating)
(6)
(7) LED
11.7.4.3 (Main Distribution Board; MDB)
(Main Distribution Board; MDB)
(1)
(2)
(3) Mimic Diagram
Single Line Diagram
11.7.4.4 (Main Distribution Board; MDB)
(1)
400/230
(Rated Operation Voltage) 690
Rated Current -
Case - (Frame Size) 1,000
Molded Case Circuit Breaker
- 1,000 Air Circuit Breaker
Incoming Unit
Ground Fault Protection (GFP)
Mounting - 1,000
Draw out type
.1
( 2) -13
1 :
- 1,000
Fixed type
Terminals -
- 100
- 250
-
Interrupting Capacity (IC)
(2) Phase Failure Relay and Under/Over Voltage Relay
Solid State 400 / 230 3 4 50
5% 15% Asymmetry Changeover 2
380 6
Plug in Socket Plug and
Socket
(3)
Cartridge
20 kA 380V
Flush Mounting
(4) Current Transformer (CT)
Secondary rated current: 5A, Primary Rating Accuracy Class:
1.5 Tropical Proof, 500 Rated Burden
(5) Voltmeter
0-500 V Accuracy Class: 1.5
(6) Digital Power Meter (D.P.M)
- Measurement Type: Three-phase four-wire ac system
- Measuring accuracy Current 0.2%
- Measuring accuracy Voltage 0.2%
-Measuring accuracy Power 0.5%
- Working power Supply 80-270 VAC
(7) Ammeter
Ammeter Primary Current Rating
Current Transformer 5 Secondary Rated Current, Accuracy Class
1.5
(8) Amp Selector Switch (AS)
.1
( 2) -14
1 :
4 3 (O-RST)
10 CT
(9) Pilot Lamps
2
- 220 V E14
- 24 V BA9S, 24 3
(10) Surge Arrester
Surge
(Surge
Protection Device Class I+II)
IEC
11.8
Corridor
11.8.1
11.8.1.1
12
2.0
Dead End
.1
( 2) -15
1 :
11.8.1.2
3
100 x 100 x 3,200
100 x 100 x 2,500
11.8.1.4
Lines /
100x100x2,500
/
11.8.1.5
11.8.1.6
(1)
4
.
25
(2) Lightning Arresters
Lightning Arresters
50
.1
( 2) -16
1 :
11.8.2
11.8.3
(...)
11.8.3.1 (60227 IEC 01)
.11-2553 THW .11-2531
Cable Trays, Cable Ladder
11.8.3.2 2 3
(VAF VAF-G) .11-2553
(Wire way)
11.8.3.3 Cable Trays Cable
Ladder (NYY NYY-G)
XLPE (0.6/1kV. CV) .11-2553
11.8.3.4 Box
Compression Bolt Screw Wire Nut Twist Wire Splice
Wire Mark Branch Circuit Pull Box Wire Marker
Panel Board Color Code
Phase 1 (A)
Phase 2 (B)
Phase 3 (C)
Neutral N
Ground GN
.1
( 2) -17
1 :
11.8.3.5
11.8.3.6
11.8.3.7 Pull Box Hand Hole
Compound 3M
11.9
( ...)
11.9.1 ()
Diagram
11.9.2 ( 3 )
(Coupling) (Connector)
(Concrete tight) (Rain tight)
(Screw tight)
11.9.3 (Conduit Support) Conduit Strap
2.00
3 Unistat
11.9.4 Heavy Duty
Flexible Conduit 0.30 1.00
Heavy Duty Flexible Conduit (Rain tight)
11.9.5
Lock Nut Bushing
Lock Nut Reducing Washer
11.9.6
11.9.7
(EMT)
11.9.8.1 Corridor
.1
( 2) -18
1 :
11.10
( ...)
11.12
( ...)
11.13
( ...)
11.14
( ...)
11.15 (BOX)
( ...)
11.15.1 Diagram
11.15.2
11.15.3 Lock Nut Bushing
11.15.4
11.15.5
Box
11.15.6 Knock Out
Block Out Box
11.15.7
Boxes
11.15.8 Junction, Outlet Pull Box
Boxes
11.15.9 Boxes
.1
( 2) -19
1 :
Boxes
11.15.10 Boxes
Boxes
11.15.11 Boxes
11.15.12 Colors Code Colors
Code
11.16 ,
( ...)
11.17
11.17.1 1.35
11.17.2 300
11.17.3 0.35
11.17.4 ()
1.00
11.17.5
: (Waterproof, WP)
1.35
0.35
Panel Board 1.50
.1
( 2) -20
1 :
11.18.1 0.10
11.18.2
(Single line diagram)
11.19 (GROUNDING)
11.19.1 5
11.19.2
11.19.3
11.19.4
Surge Arrester Isolate
11.19.5 (Ground Test Box)
11.19.6
11.19.7 2
11.19.8
11.20
11.20.1
(PB), (LC), , , , , ,
(Grounding System)
.1
( 2) -21
1 :
11.20.2
(1) 50%
(PB), (LC), , , , ,
, (Grounding System)
:
(3) 20% (Commissioning Test)
(As-Built Drawing)
(Operation Manual and Preventive) (Training)
.1
( 2) -22