Professional Documents
Culture Documents
Product Description
1. INTRODUCTION ................................................................................................................... 3
3. APPLICATIONS .................................................................................................................... 5
3.1. Advantages .................................................................................................................................... 5
3.2. Fiber optic access network ............................................................................................................ 6
3.3. DLC Backhauling ........................................................................................................................... 6
3.4. Microwave Networks ...................................................................................................................... 6
3.5. Private networkS ............................................................................................................................ 6
3.6. Public utility company networks ..................................................................................................... 6
3.7. Ethernet over SDH (EoS)............................................................................................................... 7
5. OPTICAL ENGINEERING................................................................................................... 14
5.1. Optical link budget........................................................................................................................ 14
6. INSTALLATION .................................................................................................................. 15
6.1. Mechanical installation................................................................................................................. 15
6.2. Wiring ........................................................................................................................................... 15
7. SUPERVISION/MAINTENANCE......................................................................................... 16
7.1. Supervision .................................................................................................................................. 16
7.2. Maintenance................................................................................................................................. 18
8. SPECIFICATIONS............................................................................................................... 19
8.1. Electrical and optical specifications ............................................................................................. 19
8.2. Supervisory interfaces ................................................................................................................. 20
8.3. Mechanical specifications ............................................................................................................ 20
8.4. Power supply................................................................................................................................ 20
8.5. consumption................................................................................................................................. 20
8.6. Environmental conditions............................................................................................................. 20
8.7. Guaranteed attenuation ............................................................................................................... 21
1. INTRODUCTION
SAGEM ADR622 is a STM-1 and STM-4 Add- Very flexible and compact, the SAGEM ADR622
drop Multiplexer" with a 16 VC4 switch non supports traditional TDM traffic through SDH
blocking at VC12, VC3, VC4 levels and PDH and PDH interfaces but is also optimised for
and SDH protected accesses. data transport with for instance the GFP2500
unit which has a real Ethernet Switch and offers
SAGEM ADR622 is part of SAGEM all the Ethernet over SDH enhanced features
Communications SDH solution which also is for Giga Ethernet interfaces. It gives to all
made of SAGEM ADR155C, SAGEM ADR2500 Ethernet interfaces the benefits of SDH,
eXtra, SAGEM ADR10000 and the network maturity, protections, integration into an existing
management system SAGEM IONOS NMS. network
This solution offers all the services from 2Mbit/s
up to STM-4 including the transport of Ethernet
The equipment is SNMP native and has an
over SDH.
embedded HTTP server, SAGEM ADR622 is
This solution is particularly compact, scalable
managed by SAGEM SDH Network
and easy to install and support.
Management System, IONOS NMS (which also
manages SAGEM ADR155c, SAGEM
Because of its compactness, its high degree of
ADR2500eXtra, SAGEM ADR10000 and other
protection, and its enhanced Ethernet over SDH
products from SAGEM Network division).
features, SAGEM ADR622 fits with Utility
networks, to DLC/DSL backhauling in low
density area and to SDH microwave networks.
3. APPLICATIONS
3.1.5. SNMP MANAGEMENT SYSTEM
3.1. ADVANTAGES The SAGEM ADR622 implements an HTTP
server. This enables monitoring of alarms or
3.1.1. TRUE VOICE/DATA INTEGRATION events and configuration of any equipment in the
AND PROTECTION network. This application is a friendly graphical
windows-type man-machine interface.
The SAGEM 622 is compliant to SDH standards The SAGEM IONOS-NMS is an SNMP
and it is a versatile add-drop multiplexer with a management platform that includes a
diversity of access (including 2 Mbps, 34 Mbps, provisioning feature. This software, adaptable to
45 Mbps, Ethernet, Fast Ethernet, 155 and 622 the size of the managed network, runs on a
Mbps, evaluative to 2,48 Gbps) with high quality Windows XP or a UNIX workstation; it features
of service (traffic protection). multi -users and differentiated services with
access security.
3.1.2. HIGHLY PROTECTED EQUIPMENT
SDH design of ADR622 gives the benefit of 3.1.6. A SDH COST-EFFECTIVE
standard traffic protections (SNCP and MSP). SOLUTION
Cards whose failure could affect the traffic can Money saving is a leading goal of the SAGEM
be protected in 1+1 mode and tributaries can be SDH family. Generally speaking, SDH/SONET
protected in 1:4. has proven to be one of the most cost-effective
technologies at the present time and the most
widespread world-wide.
This very important advantage is the result of a
3.1.3. COMPACT, SIMPLE AND RELIABLE three dimensional concept.
EQUIPMENT First, ADR622 takes advantage of SAGEM
The SAGEM ADR622 is very compact: experience in designing next generation cost-
dimensions are 450 x 280 x 275 mm. effective and highly integrated equipment.
Its high level of integration means it is also The second point is, it is easy to install and
reliable and low consumption equipment. commission; Commissioning is time saving.
And last, but not least, it is very simple to install The third point is the management and
and to commission (default configuration maintenance: the management is very simple
flexibility and self-adaptive behaviour). with the centralised IONOS-NMS system and
Maintenance is reduced due to the high
reliability of the equipment. Moreover, new
firmware can be downloaded to equipment from
3.1.4. SCALABILITY IONOS-NMS without going to every site.
The SAGEM ADR622 is a versatile platform. It
can be configured as an add-drop, a terminal
multiplexer, a regenerator or a cross-connect.
The SAGEM ADR622 features 8 not dedicated
slots for tributaries. It can give access at the
same time to 168 E1 (protected in 1+4) or 14
STM-1.
The heart of the system is made on a 16x16
VC4/VC4-4c/VC3/VC12 non-blocking Switch.
One service per customer port, one service per Each port has its Policing is provided per port,
VCG CAC defines the admitted capacity, RSTP and
MSTP provide protection in meshed networks.
STM-1/ 4 STM-1 / 4
4. FUNCTIONAL
DESCRIPTION
16x16 VC4/VC4-4c/VC3/VC12
4.1. ARCHITECTURE
SAGEM - ADR622 is based on a chassis with
common units (controller card, connection card,
Fan module, Switch/TSI and optional auxiliary
module), up to 6 STM-1/4 lines (2 STM-4
maximum) and 8 unallocated slots for tributaries.
Up to 12 STM-1, 168 E1, 24 E3/DS3, 16 E/FE
4 GbE
4.3. AGGREGATES
4.2. COMMON UNITS
4.3.1. STM-1/4 UNIT
4.2.1. FAN MODULE This card is a small carrier card on which you
plug STM-1 or STM-4 SFP modules (6 modules
The sub-rack includes a ventilation module. maximum, 2 STM-4 maximum).
The FAN Unit is removable, and can be
changed without interrupting the traffic. It is 4.3.2. SFP S-1.1
made of 5 modules. When one fails, an alarm
This SFP offer 0 to 12 dB at 1300 nm.
message appears informing the operator.
However, the FAN is still providing enough
cooling to the subrack. 4.3.3. SFP L1.1
The Switch is the heart of the equipment; all This SFP offer 10 to 28 dB at 1550 nm.
cards are connected to this unit. It performs all
the switching on 16x16 VC4 @VC12/VC3/VC4 4.3.5. SFP S-4.1
and synchronisation. It also performs the
protections (SNCP, MSP). This SFP offer 0 to 12 dB at 1300 nm.
It uses GFP (Generic Format Protocol), LCAS 4.4.9. 3 E3/DS3 UNIT FRONT ACCESS
(Link Adjustment Adaptation System) and virtual
concatenation in order to split the signal into This tributary card connects 3 E3 or DS3 front
from 1 up to 7 VC4. The operator can therefore access. It cannot be protected.
configure the capacity used in the SDH frame to
transport the Gigabit interface. This traffic as it is
4.5. PROTECTION
4.5.2. (SNC-P) 1+1 PATH PROTECTION
All the main protection modes are possible with
the SAGEM ADR622: SNC-P path protection is used in ring topologies
and consists in using the two sides of the ring:
STM-n MSP 1+1 (for STM-1 and STM-4 in one for the normal path, the other for the backup
case of point to point) path.
VC12, VC3 or VC-4 path protection (SNC-P)
When detected on the main channel, the
4.5.1. MSP PROTECTION 1+1 following fault conditions initiate a switch:
SF (Signal Fail): logic OR of:
STM-n line protection is obtained by doubling
the fibber optic cable and the STM-n interface AIS detection at path termination (LP-
module (1+1): AIS)
transmission over two channels, main and Byte B3 excessive bit error rate (EBER-
backup B3)
Receiving-end selection from either channel. SD (Signal Degrade):
B3 bit error rate greater than
There is automatic switchover to the protection configurable threshold.
link in accordance with the criteria described in
ITU-T recommendation G.823. There is no The SF and SD indications are processed and
interruption to the orderwire and data flows with filtered (fault persistency filter with configurable
MSP 1+1 protection. time persistency).
5. OPTICAL ENGINEERING
5.1. OPTICAL LINK BUDGET In SDH networks, the system penalty does not
affect optical output power parameters because
The equipment (or system) power budget is the latter include temperature variations
expressed as dB available between the S and R (5C/45C) and above all ageing.
interfaces of the system, i.e. the difference
between average transmitter output power and
the optical input power necessary to obtain a
BER value equal to or less than 10-10.
6. INSTALLATION
6.2. WIRING
All wiring accesses are on the front panel of the sub-rack.
7. SUPERVISION/MAINTENANCE
7.2.2. SELF-TESTS
7.2. MAINTENANCE
The SAGEM ADR622 software carries out
7.2.1. ALARMS software self-tests:
at start-up,
The SAGEM ADR622 System provides
operators with various fault detection and faulty periodically,
card isolation facilities for maintenance upon insertion of a new module.
purposes. These routines are transparent to operations
On the SAGEM ADR622 equipment: and do not affect service.
Color-coded LEDs on each card,
Two network management relay contact 7.2.3. LOOPBACKS
alarms. The SAGEM ADR622 has integrated loopback
Via the NMS: functions to aid the operator in diagnosing local
current alarms status, multiplexer or network faults.
alarm and performance event logs,
network, link or equipment level view. STM-n Line Loopback
The SAGEM ADR622 has four remote
signalling inputs ("TSIG") for external equipment Equipment loopback applied to the main or
alarm notification. standby STM-n line is used for testing the
equipment. Line loopback applied to far-end
equipment via the main or standby STM-n line is
used for testing the transmission path.
ADR622
VC4
Transmission
Equipment
optical
Reception
Line loopback
ADR622
VC4
Transmission
Equipment
optical
Reception
Equipment loopback
8. SPECIFICATIONS
G.703 2 Mbit/s 120ohms G.703 2 Mbit/s 75 ohms G.703 34/45 Mbit/s 75 ohms
Bit rate 2,048 Mbit/s 2,048 Mbit/s 34 ou 45 Mbit/S
Standard G.703 G.703 G.703
Code HDB3 HDB3 HDB3
Connector Sub D Sub D 1.0/2.3
G.703 155 Mbit/s 155 Mbit/s optique 622 Mbit/s optique 2488 Mbit/s
optique
Bit rate 155.520 Mbit/s 155.520 Mbit/s 622.080 Mbit/s 2488.320 Mbit/s
Standard G.703 1310 or 1550 nm : 1310 or 1550 nm : 1310 or 1550 nm :
ITU-T G.957 ITU-T G.957 ITU-T G.957
Code CMI NRZ NRZ NRZ
Connector 1.0/2.3 SC ou LC SC ou LC SC ou LC
Laser supervision Oui Oui Oui
Optical safety Oui Oui oui
Subrack weight 10 kg
8.5. CONSUMPTION
Operating temperature
normal (class 3.2) +5C to +45C
extended (class 3.3) -5C to +55C
ESD ETSI
(*) Available between S (Tx) and R (Rx) interfaces as defined in ITU-T Rec. G.957 (10-10 BER)