You are on page 1of 1

BK TAN CONSULTANTS

Project: BOLT FOR SAFETY LIFE LINE


Made by Date
Client: DAL BUILDERS PLE LTD DUY 27-Oct-16
Location: 412 UPPER CHANGI ROAD Checked Revision
Subject: SINGLE HILTI BOLT CONNECTION BKT -
Bolt M16 HILTI HLC - EC
Class = 8.8
Design resistance:
Fv,Rd = 10.36 kN
Ft,Rd = 5.23 kN

Load: Weight of worker (Including life line and equiment) = 0.9kN


Maximun shear on bolt:
Fv,Ed = Ved * 1.5 = 1.35 kN < Fv,Rd Ok
Maximun tension on bolt:
Ft,Ed = Ned * 1.5 = 0.95 kN < Ft,Rd Ok
Check for combined shear and tension:
Fv,Ed Ft,Ed
+ = 0.26 1 Ok
Fv,Rd 1.4Ft,Rd

METHOD STATEMENT
1 - To install Hilti-bolt M16 on existing RC beam.
2 - To carry out the pull out test to 2 x 90kg = 180kg (No failure test is required).
3 - Pull-out test to be conduct by Hilti-Test Specialist.