132562|20170713|20170713|DTR0000103066|TILTING: TMS 1 AND 2 IN FAULT CAUSING TILTING TO BE OFF LINE|490T4051|2004|6365007|8717.01| 132563|20170718|20170810|DTR0000088344|ELECTRICAL DISTRIBUTION: LVPS Regulator Fault Active (multi|U1414|3559|6399395|14438.12| 132564|20170807|20170807|DTR0009141211|PROPULSION: 25% Electric Brake Loss| 000000000001059811|2003|6410736|18906.72| 132565|20170713|20170817|DTR0000103066|TILTING: TMS 2 Failure|000000000099074051| 2004|6424522|8717.01| 132566|20170717|20170720|DTR0000120974|PROPULSION: FCU POWER BLOCK BICC CARD IN FAULT|000000000000010061|2003|6390110|893.14| 132567|20170719|20170719|DTR0000088344|ELECTRICAL DISTRIBUTION: LVPS bad out of stock|U1493|3305|6371036|14438.12| 132568|20170801|20170801|DTR0000121083|Propulsion/Electric Braking - REAR pan 957 change out for 3|000000000000000960|2008|6401432|11244.6| 132569|20170801|20170813|DTR0009114307|PROPULSION: MAP 100 reported Rect & Chop 2 isolated|000000000000001815|2002|6420621|3206.55|Note1: Replaced MO-CV-22 after unit was found to be defective after being metered. s/n in: 1794 s/n out: 1815 132570|20170811|20170717|DTR0000103065|TILT; TCC|000000000000022080|3208|6370318| 8581.26|Note1: TS-14, FC 3208, WO#6370318 - TILT: MAP100 Tilt fault CC 3208 - Trainset arrived for S&I with tilting operational. Review of MEs show no faults logging and review of the status screen shows tilting in green. Monitor for two more days (07/09/2017).Note2: If the TCC swap does not correct this issue please check the connections to PS-3 as it is having spikes that will put tilting into fault and if connections are all good have PS-3 changed out with new.Note3: TS 14 FC 3208 WO 6370318 Map 100 reports "NO TILT" Reviewing MEs for this PC finds that this car again logged tilt faults at 15:22:09-10 and at 16:29:59. The TCC has been replaced and a clean & calibrate has been done. Reviewing EDRs shows PS3 giving erratic data. Per previous notes, please replace PS3.Note4: TS-14, FC-3208, CWO# 6370318- TILT: MAP100 Tilt fault CC 3208- Updated WO title and priority. Train arrived on S&I with THC1 and THC2 in fault displaying on status screen. MEAP revealed TCADP, THS Branch 1 and THS Branch 2 failed. Informed operations to have QMP preform tilting troubleshooting steps for FC 5012, 5051 and 5050.Note5: TS-14, FC-3208, CWO# 6370318- TILT: MAP100 Tilt fault CC 3208 - Tilt fault reappeared at 14:33:37. EDR file shows PS3 spiked. QMP inspected position sensors again but found them good. We swapped TCC with car 3525 to see if fault follows (WO# 6372394). We titled both cars for 10 minutes each script for both branches but fault did not come back. Also, massive ground fault is now gone which could have caused the issue. S/N installed:98102011Note6: TS-14, FC-3208, CWO# 6370318- TILT: MAP100 Tilt fault CC 3208 - So far no events. Monitor 3 more days.Note7: TS-14, FC-3208, CWO# 6370318- TILT: MAP100 Tilt fault CC 3208 TS arrived on the turn with both THC1 and THC 2 in fault. ME's show that on 7/4 at 16:43:41 TCADP uneven tilt detected and then 13 sec later at 16:43:54 THS branch failed. At 18:44:26 Cmd vs Resp fault and at 18:44:27 PS1 and PS4 out of range. At 18:44:28 T 132571|20170714|20170816|DTR0009404562|HVAC A-END LOW SUCTION PRESSURE FAULT HOT CAR|000000000000000195|3203|6425342|5869.42| 132572|20170731|20170801|DTR0000124198|Communications: CCU IN FAULT| 000000000000000123|3559|6402718|943.18| 132573|20170713|20170807|DTR0000120565|WASTE&WATER:BAD TOILET|81-991108|3306| 6414659|4276.65|Note1: Replaced toilet 132574|20170808|20170809|DTR0009404241|Doors: Replace missing DCS| 000000000000000112|3314|6415158|2573.73|Note1: No Notes - EL 132575|20170802|20170724|DTR0000230196|CWO Oped to Issue Material Issued on Degrade. See CWO 638729|000000000015200011|3301|6388070|1933.48| 132576|20170813|20170718|DTR0000088344-B|ELECTRICAL DISTRIBUTION: LVPS Not Operating|U1740|3559|6371126|44656.81| 132577|20170714|20170719|DTR0009114307|PROPULSION: Glycol leak on chains 3 and 4| R155|2017|6385738|3206.55| 132578|20170714|20170719|DTR0009114307|PROPULSION: Glycol leak on chains 3 and 4| 000000000000001359|2017|6385738|3206.55| 132579|20170714|20170719|DTR0009114307|PROPULSION: Glycol leak on chains 3 and 4| 000000000000001148|2017|6385738|3206.55| 132580|20170807|20170817|DTR0000120565|eMAP21A-(Toilet Fixture Broken) Toilet water kept running.|81-991010|3523|6426290|4276.65|Note1: Removed S/N 81-991010 Installed S/N 81-99304 132581|20170807|20170817|DTR0000120565|WASTE & WATER : Toilet overflowing|81- 980903|3403|6426470|4276.65|Note1: Removed S/N 81-980903 Installed S/N 81990714 132582|20170717|20170720|DTR0000103065|Tilt: Defective TCC|000000000099102664|3525| 6385533|8581.26| 132583|20170808|20170713|DTR0000117610|ADU WENT DARK|000000000000899005|2011| 6356061|6788.07| 132602|20170801|20170822|DTR0000123751|Electrical Distribution System:Outlet-110v AC Broken BREAKE|000000000099122119|3302|6323861|8492.11| 132603|20170720|20170817|DTR0009404343|microwave #2 (lower) is not efficient. Reported on the map.|000000000001142365|3317|6427799|1621.3| 132604|20170812|20170820|DTR0009114307|PROPULSION: MAP 100 reported 50% Traction loss and 25% Elect|000000000000001794|2002|6429419|3206.55| 132605|20170817|20170824|DTR0009405365|GALLEY:Chiller missing|000000000000000099| 3307|6434404|5094| 132606|20170804|20170817|DTR0000230196|Galley: Chiller Missing|000000000015270026| 3409|6395477|1933.48| 132607|20160829|20170824|DTR0009404343|Galleys: Defective Microwave|12997533JP| 3204|6435464|1621.3|Note1: No Notes - EL 132608|20170720|20170823|DTR0009141214|PROPULSION: MPU1 KEEPS LOGGING MPU FAULT| 000000000001119811|2000|6425174|2913.67|Note1: MAP100 reported that the pantograph in lead power car (PC2000) dropped unexpectedly after KIN. PC2000 came in with active trainset FIP loss. An electrician reset MPUs and got trainset FIP back synchronized. I noticed that there were bunch of MPU1 fault logged in MEs. MMAP from MPU1 and MPU2 were retrieved, but there was no events in MPU1. I checked the history with the MPU1 (S/N: 1119811) and found that it was changed with the same issue from TS16. A request to change the MPU1 was made, and an electrician replaced it with no exception. Please monitor for 5 days. 132609|20170717|20170822|DTR0000119708|ACSES: Excessive Missed Transponders| 000000000000001061|2030|6387793|6875.8| 132610|20170717|20170822|DTR0000090224|ACSES: Excessive Missed Transponders| 0032/184|2030|6387793|1272.94| 132612|20170115|20170822|DTR0000083996|TRUCK/WheelSet/Suspension: Truck Hunting A Alarms|000000000000092211|3214|6370192|501.42| 132613|20170620|20170822|DTR0009404241|DOORS: Door 3 DCS internal fault| 000000000000000067|3538|6432608|2573.73| 132614|20170816|20170824|DTR0009404773|GALLEYS: Toaster B/O|09-1019012-RAB|3211| 6435379|332.6| 132615|20170325|20170824|DTR0009405365|chiller missing|000000000000000009|3419| 6435332|5094|Note1: No Notes - EL 132616|20170605|20170823|DTR0000103061|Inspection Punchlists|000000000000245013| 3310|6379940|11074.89|Note1: No Notes - EL 132617|20170815|20170820|DTR0009404660|Tilt: TMS INOPERATIVE # 1| 000000000000000181|2031|6429999|16932.06| 132622|20170802|20170825|DTR0009404242|HVAC:Blower Problems electrical closet fan b/o|000000000000000124|3318|6436832|996.43| 132623|20170818|20170824|DTR0000119708|ACSES: Antenna error (2000)|0078/750|2010| 6427802|6875.8| 132624|20170818|20170824|DTR0000090224|ACSES: Antenna error (2000)|0054/292|2010| 6427802|1272.94| 132662|20161117|20170828|DTR0026313AAF|ELECTRICAL DISTRIBUTION: LVBC 1 in fault| 02K0176|2027|6401712|3059.67| 132663|20170523|20170825|DTR0000088344|ELECTRICAL DISTRIBUTION: (DELAY) LVPS not actively charging|U1571|3415|6418016|14438.12| 132664|20170313|20170828|DTR0009114307|PROPULSION: Major glycol leak from rear central block|000000000000001810|2011|6439305|3206.55|Note1: (RM) TS 17 PC 2011 WO 6439305 Major glycol leak from rear central block Deadhead run - no delay No MAP report Received multiple MEAP alerts This TS arrived with chains 2 3 and 4 isolated, and multiple propulsion MEs. Reviewing ME and MMAP downloads indicated multiple ground faults, overcurrents, and water pressure faults. Checking the power modules with the PTE indicates no shorted power modules, but, there was glycol leaking from the bottom of the rear central block onto the main transformer below and also into the walkway in the power car. It appears that the power modules at location IRT-34 and IRT-23 are both leaking, and there is debris from the power module internals on bottom plate of the power module. As a first step in repair, the bottom three power modules (IRT-34, IRT-33, and IRT-23) will need to be removed, and likely replaced, and the P2 modules will need to be removed and checked for proper capacitance. Then, the leaked glycol will need to be cleaned up and dried, and the piping will need to be checked for leaks. Then, please install the P2 modules (replace any that are out of spec) and install NEW B2 modules for the bottom three positions, and then refill the glycol and check for leaks. Photos will be attached to this W/ONote2: PC was powered up and Converter #2 isolated with 32-22 Long Precharge Fault Rec 2, this was inspected and reset and then the same fault. MCB was re-closed and #4 isolated with 34-22 Long Precharge Fault Rec 4. The Central Blocks were opened and inspected but nothing out of the ordinary was seen. Perturbographs were installed but would not trigger with the faults. The next step is to follow the RMM 00-32-22 Page 3 of 5 step #2 for both 32-22 and 34-22. This should be the next step in troubleshooting. The plan is to bring it back inside tomorrow morning. More to follow.Note3: Inspected rear Motor Block, IRT-23 IRT-33 and IRT-34 were wet at their bases with Glycol. Both sight glasses were empty,N 132665|20170519|20170829|DTR0009404241|Doors: Malfunctioning|000000000000000391| 3544|6441560|2573.73| 132666|20161107|20170827|DTR0000091086|TRUCKS AND SUSPENSION: SECONDARY VERTICAL DAMPER|000000000000085404|2008|6438163|949.08|Note1: OLD S/N: 85404 NEW S/N: 116957 132682|20170802|20170829|DTR0000124197|eMAP21A-(PA-Public Address System) Throughout train////|000000000000000005|3316|6389867|4104.49| 132683|20170313|20170830|DTR0009141214|Propulsion: MCB WOULD NOT CLOSE| 000000000001329839|2003|6428270|2913.67| 132684|20161207|20170830|DTR0000072461|Truck/WheelSet/Suspension: Replace secondary transversal|000000000000098216|2031|6442482|792.22|Note1: No Notes - EL 132702|20170602|20170830|DTR0000074909|PROPULSION: Major glycol leak from rear central block|R93|2011|6439305|1250.39|