INVESTIGATION REPORT

विषय:लोको सं.31146 दि.24.03.18 को लाइन पर हुइ विफलता की अन्वेष्ण रिपोर्ट.


Sub: Investigation report for failure of Loco No. 31146 on 24.03.18.
Ref: HqrsLr.No. E.221/TRS/UOR/Vol-II/1305, Dt.09.08.16

<<0>>

Loco Particulars:
Loco no. 31146 Type of loco WAG-9
Homing Shed ELS/LGD Loco D.O.C 01/01/08
IOTL/75” (IND),
Date of Failure 24.03.18 Tr.No./Det./Load
1400 T
Failed
Last MajorSch.&Dt. MOH-27/10/17 DW-PSK/BB/CR
Sec./Divn./Rly.
Last Minor Sch.& Dt. IA-16/02/18 LP/Grade/HQRS K.S.Rao/KYN
Last TI done at/ Dt. -- Repercussion --

Occurrence/ Line report:


T.No.IOTL/TR (Load-1400T), After passing neutral section, VCB not closing with message
"Dis. In Con No.2". MCE OFF/ON then VCB closed but message "Low air pressure-Traction
not allowed", operated A-9 to emergency then put normal, MCE OFF/ON then ok but again
message Traction may reduce if temperature increase", tried to clear section but detained
inside tunnel for pressure dropped, same built and cleared section.
Major/Sec-Kalyan-ChatrapatiShivaji Terminal (KYN-CSTM), Minor/Sec-Diwa-Parsik-New
Mulund Yard (DW-PSK-NGSM), Time-13.15-14.23 hrs.

Log book remarks:


On 24.03.18 while working with T.No.IOTL, between DW-TMBY, after passing N/S
experienced fault message F0301P1, trouble shootedasper TSD & further experienced fault
message F1002P1, trouble shootedasper TSD and finally experienced fault message
F1101P2 & worked upto NGSM and loco made dead.
Failed Equipment Details:
Equipment Make S.No. DOC Last tested
SR BHEL T30118 13.12.07 --
Sub.Equip. Make S.No. DOC Last tested
NSC2 CARD Rehab by INDOCEN 013-2006 05.06.16(Re-hab) --

Shed observations/Investigation details :


Loco arrived to ELS/LGD on 03.04.18 in dead condition. From the DDS it is observed that
the following fault messages logged during occurrence time.
1) 24-03-18 13:26:20 007 NSC2:0036-Error operating software
2) 24-03-18 13:26:27 400 FLG1:0091-Power on of MCE
3) 24-03-18 13:26:28 300 HBB1:0011-Scav. oil cooler MCB open
4) 24-03-18 13:30:07 400 FLG1:0091-Power on of MCE
5) 24-03-18 13:30:08 300 HBB1:0011-Scav. oil cooler MCB open
6) 24-03-18 13:31:41 000 FLG1:0040-S/R interlock - main res. low
7) 24-03-18 13:38:09 400 FLG1:0091-Power on of MCE
8) 24-03-18 13:38:10 300 HBB1:0011-Scav. oil cooler MCB open
9) 24-03-18 13:38:21 007 NSC2:0036-Error operating software
10) 24-03-18 13:39:21 400 FLG1:0091-Power on of MCE
11) 24-03-18 13:39:22 300 HBB1:0011-Scav. oil cooler MCB open
12) 24-03-18 13:39:42 015 NSC2:0036-Error operating software
13) 24-03-18 13:39:43 002 NSC2:0033-Error plausibility Iq2
14) 24-03-18 13:39:43 005 NSC2:0033-Error plausibility Iq2
15) 24-03-18 13:39:43 008 NSC2:0032-Error plausibility Iq1
16) 24-03-18 13:39:43 011 NSC2:0032-Error plausibility Iq1
17) 24-03-18 13:39:43 800 SLG2:0069-High frequency catenary voltag
18) 24-03-18 13:39:43 800 SLG2:0066-Low frequency catenary voltage
19) 24-03-18 13:39:46 800 SLG2:0069-High frequency catenary voltag
20) 24-03-18 13:39:46 800 SLG2:0066-Low frequency catenary voltage
21) 24-03-18 13:41:46 400 FLG1:0091-Power on of MCE
22) 24-03-18 13:41:47 300 HBB1:0011-Scav. oil cooler MCB open
From the above messages, it can be seen that LP initially experienced DJ tripping with fault
message “NSC2:0036-Error operating software”, but SR was not isolated.Instead of
reclosing the DJ, LP wrongly switched OFF/ON the MCE. After switching ON the MCE, LP
experienced a Priority-2 fault message “HBB1:0011-Scav.oil cooler MCB open message
logged”. This message neither caused DJ tripping nor caused isolation of subsystem.
Instead of working the train duly checking the HB-1 panel for any MCB tripping, again LP
wrongly switched OFF/ON the MCE which caused MR pressure dropped below 5.6 Kg/Cm 2
and caused “SR Interlock-main reservoir low” fault message. LP, instead of waiting for
building up the MR pressure, LP again wrongly switched OFF/ON the MCE. Further, LP
getting continuous problem of “NSC2:0036-Error operating software” LP instead of
manually isolating the defective SR-2 and work the train further with single bogie, LP again
switched OFF/ON the MCE. In this process, LP totally 5 times wrongly switched OFF/ON the
MCE and caused huge detention in mid-section/punctuality loss.
Loco was examined at ELS/LGD and found both SRs are working normal. During occurrence
time fault messages 1) NSC2:0036-Error operating software 2) NSC2:0032/33-Error
plausibility Iq2 logged. Hence, NSC-2 card was replaced.
From the records it is observed that the above NSC-2 card of M/s.BT make was
rehabilitated by m/s.Indocen on 05.10.16 and further this card was provided in loco
No.31173 on 21.06.16. The same card failed on 13.04.17.hence, card was sent for warranty
repairs to M/s.Indocen. Further on receipt of the card after warranty attention, the same
card was provided in this loco on 20.10.17.
Regarding, HBB1:0011-Scav. oil cooler MCB open checked and found at times only message
is coming but MCB was not tripped due to MCB aux.I/L defect i.e.at times not closing. This
is an identified problem in Schneider make MCBs. Hence, Scavenger blower MCB auxiliary
inter locks were replaced.

Analysis of root cause/Probable cause of failure:


NSC2:0036-Error operating software fault message logged due to mal-operation of NSC-2
card which was rehabilitated by M/s.Indocen. LP instead of isolating the defective SR-2 and
work further with single bogie(trailing load only 1400tonnes), he repeatedly wrongly
switched OFF/ON the MCE for 5 times which caused huge mid-section detention/punctuality
loss.

Responsibility:
Primary: Crew Secondary:M/s.INDOCEN

In case of defective Main.Shed:


Supervisor/Staff responsible: --
No.of years working on the maintenance of Equipment: --
Any failures of equipment due to bad workmanship of above staff earlier: --
Date of counselling of concerned staff (includingobtaining
--
acknowledgement in counselling register):

Failure Trend (No.of Similar failures):


During last year Current year
-- --

Previous Reliability action plan/MS/SMI/TC followed to avoid above type of


failure:
--

Action taken to avoid re-occurrence of failure:


1) Sr.DEE/TRO/BB is advised of the crew mis-manipulation and to counsel the crew
suitably to avoid repetition of such incidences in future.
2) M/s.Indocen has been advised of the NSC card failure and to submit the investigation
report.

Assistance required from Hqrs.


C.Rly may be suitably advised to re-classify the above occurrence from loco to crew account

(ko.qaaOyaa-)
वरि.मं.वि.इं.
विध्युत लोको शेड, लालागुडा
Title : 31146 Page: 1
Doc Id: 31146 Date: 03-04-18 11:24:28
Malfunction overview
Vehicle: WAP Project version: 25 File: 171104XA.146
Vehicle identifier: wag9 146
RefNo Date Time ms Signal description FKl Sub-name Signal name Counter
-----------------------------------------------------------------------------------------------------------------
1242 17-03-18 19:58:18 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1243 17-03-18 19:59:15 100 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1244 17-03-18 20:04:09 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1245 17-03-18 20:05:13 199 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1246 18-03-18 01:43:45 600 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 1
1247 18-03-18 02:07:34 700 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 1
1248 18-03-18 02:07:40 000 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 2
1249 18-03-18 02:10:16 300 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 2
1250 18-03-18 03:31:41 700 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 3
1251 18-03-18 04:25:03 000 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 4
1252 18-03-18 05:48:22 600 HBB2:0004-Fire alarm 2 detected @ SS15 09--_0901-MFireAlarm 1
1253 18-03-18 05:48:22 700 FLG1:0088-Smoke warning fire det. eq. @ SS15 09--_0902-MSmogWarn 1
1254 18-03-18 23:02:44 600 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 1
1255 18-03-18 23:08:23 200 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 1
1256 19-03-18 00:10:34 100 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 5
1257 19-03-18 03:12:35 600 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 6
1258 19-03-18 05:53:04 699 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 7
1259 19-03-18 12:34:17 100 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 3
1260 19-03-18 15:03:59 900 FLG1:0118-Constant speed switch stuck @ NOSUB 53--_5315-MBPCS-Stuck 1
1261 19-03-18 15:38:12 300 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 2
1262 19-03-18 19:39:00 199 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 4
1263 20-03-18 03:10:55 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1264 20-03-18 07:47:47 000 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 1
1265 20-03-18 07:55:04 600 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 2
1266 20-03-18 09:49:06 700 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 3
1267 20-03-18 10:34:19 900 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 1
1268 20-03-18 12:28:53 000 HBB2:0004-Fire alarm 2 detected @ SS15 09--_0901-MFireAlarm 1
1269 20-03-18 12:28:53 100 FLG1:0088-Smoke warning fire det. eq. @ SS15 09--_0902-MSmogWarn 1
1270 20-03-18 14:48:08 600 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 4
1271 20-03-18 14:49:27 200 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 5
1272 20-03-18 17:30:43 000 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 1
1273 20-03-18 19:09:02 000 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 2
1274 20-03-18 19:09:06 000 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 1
1275 20-03-18 19:09:53 600 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 2
1276 20-03-18 19:09:54 000 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 3
1277 20-03-18 19:10:15 000 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 3
1278 20-03-18 19:10:22 800 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 4
1279 20-03-18 19:10:26 800 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 4
1280 20-03-18 21:29:04 800 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 6
1281 20-03-18 21:37:32 700 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 2
1284 21-03-18 03:16:41 300 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 9
1285 21-03-18 06:10:57 600 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1291 21-03-18 08:04:47 100 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 15
1292 21-03-18 19:36:40 100 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 33
1294 21-03-18 22:01:48 000 FLG1:0036-S/R interlock - auto brake A SS10 51--_5101-MS/RAutBk 1
1296 22-03-18 13:55:04 700 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1295 22-03-18 15:11:29 600 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 58
1297 22-03-18 15:21:56 600 SLG2:0049-Speed disturbance @ SS03 90--_9012-MStVIst-DG2 5
1298 22-03-18 15:22:13 000 SLG1:0049-Speed disturbance @ SS02 90--_9012-MStVIst-DG1 5
1299 22-03-18 22:29:56 400 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 77
1300 23-03-18 00:17:29 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1301 23-03-18 00:17:30 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1303 23-03-18 00:44:27 300 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 1
1304 23-03-18 12:00:57 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1305 23-03-18 12:00:58 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1307 23-03-18 12:05:18 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1308 23-03-18 12:05:19 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1324 23-03-18 15:05:49 300 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 15
1326 23-03-18 16:45:49 700 FLG1:0036-S/R interlock - auto brake A SS10 51--_5101-MS/RAutBk 1
1327 23-03-18 18:22:43 400 FLG1:0019-Emergency brake pressure sw. A SS10 43--_4301-MPrSwEmgBk 1
1325 23-03-18 20:38:46 900 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 25
1328 23-03-18 20:44:24 400 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1329 24-03-18 06:15:30 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1330 24-03-18 06:15:31 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1331 24-03-18 07:05:58 400 FLG1:0038-S/R interlock - park brake A SS10 51--_5101-MS/RParkBk 1
1332 24-03-18 11:26:45 700 FLG1:0020-Emergency brake vigilance @ SS10 43--_4301-MEmgBkVig 1
1333 24-03-18 11:26:52 500 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 1
1334 24-03-18 11:26:57 900 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1335 24-03-18 11:30:37 000 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 2
1336 24-03-18 11:46:04 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1337 24-03-18 11:46:05 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1338 24-03-18 13:22:30 000 NSC1:0080-Error PS hardware A SS02 xx--_xxxx-NSC1-StNr80 1
1339 24-03-18 13:22:30 004 NSC1:0081-PS fault storage CGP A SS02 xx--_xxxx-NSC1-StNr81 1
1340 24-03-18 13:26:20 007 NSC2:0036-Error operating software A SS03 xx--_xxxx-NSC2-StNr36 1
1341 24-03-18 13:26:27 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1342 24-03-18 13:26:28 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1343 24-03-18 13:30:07 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1344 24-03-18 13:30:08 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1345 24-03-18 13:31:41 000 FLG1:0040-S/R interlock - main res. low A SS10 51--_5101-MS/RLowMR 1
1346 24-03-18 13:38:09 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1347 24-03-18 13:38:10 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1348 24-03-18 13:38:21 007 NSC2:0036-Error operating software A SS03 xx--_xxxx-NSC2-StNr36 1
1349 24-03-18 13:39:21 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1350 24-03-18 13:39:22 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1351 24-03-18 13:39:42 015 NSC2:0036-Error operating software A SS03 xx--_xxxx-NSC2-StNr36 1
1352 24-03-18 13:39:43 002 NSC2:0033-Error plausibility Iq2 A SS03 xx--_xxxx-NSC2-StNr33 1
1355 24-03-18 13:39:43 005 NSC2:0033-Error plausibility Iq2 A SS03 xx--_xxxx-NSC2-StNr33 2
1358 24-03-18 13:39:43 008 NSC2:0032-Error plausibility Iq1 A SS03 xx--_xxxx-NSC2-StNr32 1
1359 24-03-18 13:39:43 011 NSC2:0032-Error plausibility Iq1 A SS03 xx--_xxxx-NSC2-StNr32 2
1353 24-03-18 13:39:43 800 SLG2:0069-High frequency catenary voltag B SS01 #NSC2_NSC2-MStoefN>max 1
1354 24-03-18 13:39:43 800 SLG2:0066-Low frequency catenary voltage B SS01 #NSC2_NSC2-MStoefN<min 1
1360 24-03-18 13:39:46 800 SLG2:0069-High frequency catenary voltag B SS01 #NSC2_NSC2-MStoefN>max 2
1361 24-03-18 13:39:46 800 SLG2:0066-Low frequency catenary voltage B SS01 #NSC2_NSC2-MStoefN<min 2
1362 24-03-18 13:41:46 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1363 24-03-18 13:41:47 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1365 24-03-18 13:55:48 900 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 1
1366 24-03-18 14:00:15 400 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 2
1367 24-03-18 14:04:52 000 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 3
1368 24-03-18 14:13:13 700 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 4
1369 24-03-18 14:17:09 100 FLG1:0092-ACP/Train Part @ SS10 43--_43-BBuzerTPart 5
1370 24-03-18 16:14:33 000 FLG1:0039-S/R interlock - emgbrk out A SS10 51--_5101-MS/REmgOut 1
1371 25-03-18 14:59:18 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1372 25-03-18 14:59:18 400 FLG1:0039-S/R interlock - emgbrk out A SS10 51--_5101-MS/REmgOut 1
1373 25-03-18 14:59:19 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1374 25-03-18 14:59:19 300 HBB1:0007-TM 1 blower MCB open B SS11 09--_0901-MMCBBloTM1 1
1375 25-03-18 15:03:13 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1376 25-03-18 15:03:14 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1377 25-03-18 15:03:14 300 HBB1:0007-TM 1 blower MCB open B SS11 09--_0901-MMCBBloTM1 1
1378 25-03-18 15:06:46 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1379 25-03-18 15:06:47 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1380 25-03-18 15:06:47 300 HBB1:0007-TM 1 blower MCB open B SS11 09--_0901-MMCBBloTM1 1
1381 25-03-18 15:08:28 400 FLG1:0091-Power on of MCE @ SS01 00--_0000-MPowerOn 1
1382 25-03-18 15:08:29 300 HBB1:0011-Scav. oil cooler MCB open B SS11 09--_0901-MMCBTScBlo1 1
1383 25-03-18 15:08:29 300 HBB1:0007-TM 1 blower MCB open B SS11 09--_0901-MMCBBloTM1 1