Professional Documents
Culture Documents
D. Syam
Department of Physics, Barasat Government College, Kolkata 700 124, India
10 6
129
Xe on PET Track diameters after 2 hr etching
8
5
Xe
Track diameter ( m)
Track diameter ( m)
6
Kr
4
4 Ti
2
0.5 1.0 1.5 2.0 2.5 3.0 3.5
10 20 30 40 50 60
FIG. 3: The variation of track diameter for 129 Xe tracks in FIG. 5: Figure compares the diameters of 129 Xe, 78 Kr and
PET for different durations of etching. The line is only to 49
Ti tracks on PET after 2 hr etching. The line is only to
guide the eye. guide the eye.
30
25
129
Xe on PET
Track lengths after 2 hr etching
25
20
Xe
Track length ( m)
Track length ( m)
20
15
Kr
15
10
10 Ti
5
5
0.5 1.0 1.5 2.0 2.5 3.0 3.5
10 20 30 40 50 60
FIG. 4: The variation of track length for 129 Xe tracks on PET FIG. 6: Figure compares the track lengths of 129 Xe, 78 Kr and
for different durations of etching. The line is only to guide 49
Ti tracks on PET after 2 hr etching. The line is only to
the eye. guide the eye.
of identifying incident particles when they have similar Monte Carlo code SRIM [12].
values for energy per nucleon. The nature of the calibration curve can be explained
Fig. 7 shows the distribution of VT /VB values for thus. High values of dE/dx leads to highly damaged
129
Xe obtained from track parameter measurements on polymer matrix along the latent track. But the etching
a particular PET sample. The closely bunched values process is limited by the transportation of etching
of VT /VB for 129 Xe show the consistency of the charge solution and etching products in the narrow track
response of PET. channel [13][14]. So for higher dE/dx values, large
By combining the VT /VB values for 129 Xe, 78 Kr, 49 Ti quantities of etching products cannot be removed from
as well as those for 16 O, 32 S, 56 Fe, 238 U ions obtained the track channel fast enough. So VT starts to slow
earlier [8, 9], we can get a calibration curve for PET as down, will reach a maximum and may then fall for
shown in Fig. 8. The specific energy losses dE/dx of the any further increase in dE/dx. Consequentely the
incident ions at different energies were obtained using the ratio VT /VB is also expected to show similar behavior.
4
40
charged particle, one can identify any charged particle
with its charge, mass and energy.
30
20
III. CONCLUSION
10
238
Acknowledgments
B
U
/ V
129
7 Xe
T
V
78
Kr
56
Fe
The authors sincerely thank Dr. Y. Blumenfeld and
5
49
Ti
Dr. A. Herlert of ISOLDE, CERN for their help in get-
3
32
S
ting the PET films irradiated. The authors also thank
16
O
Mr. Sujit K. Basu for technical assistance. This work
1
was performed under the aegis of the IRHPA (Inten-
0 20 40 60 80 100 120 140 160 sification of Research in High Priority Areas) Project
dE / dx [MeV / (mg / cm )]
2
(IR/S2/PF-01/2003) of the Science and Engineering Re-
search Council (SERC), DST, Government of India, New
Delhi. One of the authors, JP, has been supported by a
FIG. 8: Calibration curve for PET. Marie Curie Intra-European Fellowship of the European
Communitys 7th Framework Programme under contract
number PIEFGA-2008-219175.
[1] R. L. Fleischer, P. B. Price, R. M. Walker, Nuclear Tracks [7] B. Basu, S. Dey, B. Fischer, A. Maulik, A. Mazumdar,
in Solids, University of California Press (1975) S. Raha, S. Saha, S. K. Saha, D. Syam, Radiat. Meas. 43
[2] S. A. Durrani, R. K. Bull, Solid State Nuclear Track (2008) S95
detection-Principles, Methods and Applications, Perga- [8] A. Maulik, D. Bhowmik, S. Dey, Sibaji Raha, S. Saha,
mon Press (1987) Swapan K. Saha, D. Syam, Proceedings of the 31st ICRC,
[3] R. Klingenberg, J. Phys. G 27 (2001) 475 Lodz, Poland (Paper ID : 1072) (2009).
[4] J. Sandweiss, J. Phys. G 30 (2004) S51 [9] D. Bhowmik, S. Dey, A. Maulik, Sibaji Raha, S. Saha,
[5] S. Banerjee, S.K. Ghosh, S. Raha, D. Syam, Phys. Rev. Swapan K. Saha, D. Syam, Nucl. Instr. and Meth. B 269
Lett. 85 (2000) 1384 (2011) 197
[6] Basudhara Basu, Amal Mazumdar, Sibaji Raha, Satyajit [10] D. Voulot, Nucl. Instr. and Meth. B 266 (2008) 4103
Saha, Swapan K. Saha, Debapriyo Syam, Indian. J. Phys. [11] G. F. Knoll, Radiation Detection and Measurement (3rd.
79 (2005) 279 Ed.), Wiley (2000)
5
[12] J. F. Ziegler, J. P. Biersack, The stopping and range of and Meth. B 86 (1994) 317
ions in matter (SRIM Computer Code), Version: 2003.26 [14] F. Petersen, W. Enge, Radiat. Meas. 25 (1995) 43
(2003)
[13] A.J. Westphal, Y.D. He, P.S. Wojdowski, Nucl. Instr.