You are on page 1of 1

GF - Ground Floor

SS - Sorter Structure
100.0
sorter speed

80.0

10-Oct-07

Percent of Alert
60.0 11:38:17
To
10-Oct-07
11:45:56
40.0

20.0

.0
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 Point: 17
0 1 2 3 4 5 6 7 8 9 0 sorter speed
%Alt: 86.53
Ampl: .260

This is the result of selecting Parameter Profile for 20 points on one machine. The cursor
is on Point 17 and shows amplitude of .260 and % of alert of 86.53 which is correct since
alert is set at .3 ips. The results remain the same with the parameter set at cpm intervals of
600-900 or 828-829
GF - Sorter Structure
SS -17 LEG SWHW
0.5 Trend Display
FAULT
PK In/Sec

0.4 Overall Value


0.3
ALERT
0.2
0.1 WARNING
0
-1.0 -0.5 0 0.5 1.0
Days: 10-Oct-07 To 10-Oct-07

0.05 Route Spectrum


PK In/Sec

0.04 10-Oct-07 11:44:49


0.03 OVERALL= .0642 V-DG
PK = .0638
0.02
LOAD = 100.0
0.01 RPM = 1780. (29.67 Hz)
0
0 3000 6000 9000 12000
Frequency in CPM
2.0
PK ALARM Route Waveform
1.0
Acc in G-s

10-Oct-07 11:44:49
0 RMS = .0348
CF
CF A
ALA
LARM
RM PK(+/-) = .0824/.1016
-1.0 CRESTF= 2.92

-2.0 PK ALARM
Freq: 828.26
0 10 20 30 40 50 60 Ordr: .465
Revolution Number Spec: .01108

This is the result of double clicking on point 17. Amplitude at 828.26 is .01108 ips.
Amplitudes are incorrect at every point but closer at points 1-12.