Professional Documents
Culture Documents
General Information
Job number----------------
Customer------------------ ASCE 7-02
Job site address------------------- Geometry Building Class
ASCE Bldg Classification II 5.710593 degrees roof angle I
Eave Height ------------- 8 meter Peak Height ------------- 9.3333333 mt II
Width ---------------------- 40 meter Ave Height, h ---------- 8.6666667 mt III
Length -------------------- 500 meter IV
Pitch ----------------------- 1 10 2
Peak at -------------------- 20 meter
Internal Coefficient 0.18
Internal Coefficient l 0
Enclosed 0.18 0
P.Enclosed 0.55 0
Wind Calculation
Velocity Pressure (6.5.10)
ASCE 7-02
Building Class Load cases
ASCE 7
IBC alternate
S1 > .5
0.8
1
1.3
1.5
2.4
JOB NAME: 0
JOB NO: 0
-0.51 -0.20
-0.87 -0.56
0.59 -0.12
0.23 Full Bay ft -0.48
-0.27 -0.27
-0.63 End Bay ft -0.63
-0.51 -0.51
-0.87 -0.87
-0.27 -0.27
-0.63 Full Bay ft -0.63
Surface= 1E 2E 3E 4E
Angle 0-5 0.610 -1.070 -0.530 -0.430
20.000 0.800 -1.070 -0.690 -0.640
30-45 0.690 0.270 -0.530 -0.480
90.000 0.690 0.690 -0.480 -0.480
1 2 3 4 5 6
1E 2E 3E 4E 5E 6E
Page 5
Windloads
Main Frame
Coefficent Bay Spacing PZ LOAD
Trans. Wind load Pressure 0.22615847386 7.150 0.555455 0.90
-0.87 7.150 0.555455 -3.46
-0.5552110163 7.150 0.555455 -2.21
-0.4766322026 7.150 0.555455 -1.89
Trans. Wind load Suction 0.58615847386 7.150 0.555455 2.33
-0.51 7.150 0.555455 -2.03
-0.1952110163 7.150 0.555455 -0.78
-0.1166322026 7.150 0.555455 -0.46
Longi. Wind load Pressure -0.63 7.150 0.555455 -2.50
-0.87 7.150 0.555455 -3.46
-0.87 7.150 0.555455 -3.46
-0.63 7.150 0.555455 -2.50
Longi. Wind load Suction -0.27 7.150 0.555455 -1.07
-0.51 7.150 0.555455 -2.03
-0.51 7.150 0.555455 -2.03
-0.27 7.150 0.555455 -1.07
End Frame
Page 6
Windloads
COL-1 249
RAFTER-5
RAFTER-6 252
COL-2 8
Page 7
Windloads
Page 8
9.5.2.5.1