SECTION 68 POOLS, TUBS AND SPAS

68-404 Controls and other electrical equipment (see Appendix B)


(4) Except for a spa or hot tub installed at a dwelling unit, an
emergency shut-off switch shall be installed for each spa or hot
tub that:
(a) disconnects the motors supplying power to the closed water
circulating systems;
(b) is independent of the controls for a spa or hot tub;
(c) is located at a point readily accessible to the users and
within sight of and within 15 m of the spa or hot tub;
(d) is labelled in a conspicuous, legible, and permanent
manner, identifying it as the emergency shut-off switch; and
(e) activates audible and visual trouble-signal devices that
give immediate warning upon actuation of the
emergency shut-off switch.

Electrical Inspections
116
SECTION 68 POOLS, TUBS AND SPAS

68-308 - Other Electrical Equipment

No other (unrelated) equipment is to be fed from a circuit


feeding a hydro massage bathtub.

Access must be provided to all electrical equipment including


the pump motor.

See Rule 2-122 - Minimum 400 mm x 400 mm access panel.