Professional Documents
Culture Documents
Centrifugal Pump Maintenance
Centrifugal Pump Maintenance
IRI-SM-06-EMD
EQUIPMENT MAINTENANCE DESCRIPTION
This document is the property of Industrial Resources, Inc. Copies and distribution of this document is prohibited
unless written authorization is granted by Industrial Resources, Inc.
PREFACE
This Training Equipment Maintenance Description (EMD) has been designed to assist you in
meeting the requirements of the Maintenance Training Program. It contains information about the
Single Stage Centrifugal Pumps. This includes function, quantity of parts, location of parts,
description of the physical construction of the part, and description of the operation of the part,
equipment preventive and corrective maintenance, and references.
You should review each chapter objective. In doing so you will be better prepared to learn the
required information. You should also inspect the equipment, identifying its components and
controls. Should you have additional question about the equipment, ask your supervisor.
A separate document, Single Stage Centrifugal Pumps Equipment Maintenance Procedure IRI-SM-
06-EMP, covers detailed maintenance of the Single Stage Centrifugal Pumps Equipment.
SINGLE STAGE CENTRIFUGAL PUMPS
IRI-SM-06-EMD
TRAINING EQUIPMENT MAINTENANCE DESCRIPTION
TABLE OF CONTENTS
1.0 Introduction......................................................................................................................... 4
1.1 Equipment Function............................................................................................................ 4
1.2 Equipment Description ....................................................................................................... 4
1.2.1 Equipment Data .................................................................................................................. 9
1.3 Equipment Connections and Interface ................................................................................ 9
2.0 Equipment Major Parts ..................................................................................................... 10
2.1 Pump Casings.................................................................................................................... 10
2.2 Seal Chamber/Stuffing Box .............................................................................................. 11
2.3 Volutes and Diffusers ....................................................................................................... 14
2.3 Impellers ........................................................................................................................... 16
2.4 Wear Rings........................................................................................................................ 18
2.5 Shaft Sleeves..................................................................................................................... 24
2.6 Couplings .......................................................................................................................... 24
3.0 Equipment Preventive and Corrective Maintenance......................................................... 27
3.1 Preventive Maintenance.................................................................................................... 27
3.2 Corrective Maintenance .................................................................................................... 27
List of Figures:
Figure 1 Single Stage Centrifugal Pump
Figure 2 Single Stage, End Suction Centrifugal Pump
Figure 3 Side Suction Pump
Figure 4 Down Suction Pump
Figure 5 End Suction Pump
Figure 6 Solid Pump Casing
Figure 7 Split Pump Casing
Figure 8 Stuffing Box Assembly
Figure 9 Seal Chamber Assembly
Figure 10 Double Volute Pump
Figure 11 Diffuser Pump
Figure 12 Closed, Double Suction Impeller
Figure 13 Closed, Single Suction Impeller
Figure 14 Open Impeller
Figure 15 Impeller Flow Types
Figure 16 Flat Style Wear Rings
Figure 17 L style Wear Rings
Figure 18 Labyrinth Style Wear Rings
Figure 19 Axial Forces on a Single Suction Impeller
Figure 20 Axial Forces on a Double Suction Impeller
Figure 21 Shaft Sleeve
References:
Goulds Centrifugal Pump Manual
1.0 Introduction
Chapter Objectives:
1. Describe the functions of Single Stage Centrifugal Pumps.
2. State, from memory, the functions of Single Stage Centrifugal Pump equipment.
3. Describe how Single Stage Centrifugal Pumps are operated and maintained.
4. List the normal Single Stage Centrifugal Pump operating parameters.
Centrifugal pumps move fluids by stirring them faster and faster in a circular motion and then
changing the increased speed of the fluid into pressure. Depending on the design of the
particular pump, centrifugal pumps are capable of either very high or very low discharge
pressures and very high or very low volume discharges.
The pump shaft, driven by a motor or other prime mover, rotates, causing the impeller, which is
attached to it, to rotate also. The fluid being pumped enters through the suction eye at the center
of the impeller and fills the inside of the casing. The vanes of the impeller catch this fluid,
stirring it in the same direction as the rotation of the impeller and the shaft.
As the water gains speed (kinetic energy), it pushes outward against the walls of the pump
casing. This is due to centrifugal force - the same force that causes a stone on the end of a string
to pull outward on its string when swung in a fast, circular orbit. As the water moves outward, it
makes room for more water and at the same time creates a suction, which draws more water in at
the suction eye of the impeller. When the water is discharged at the tip of the impeller into the
volute, it is moving very fast, that is, it contains a large amount of kinetic energy.
In the volute, which widens at the discharge end, the water must spread out to fill the chamber.
In the course of spreading out, the water slows down. When the water is forced to slow down,
the kinetic energy (speed or motion) does not just disappear; it is transformed into pressure. This
pressure carries the water out of the pump through the discharge piping.
Centrifugal Pump Classifications
Centrifugal pumps are classified according to certain design features. For example, pumps can
be referred to as vertical or horizontal, single-suction or double-suction, single stage, double-
stage, or multi-stage, volute or diffuser, and radial-flow, axial-flow, or mixed flow. The name of
the pump might also include formation about the impeller: whether it is closed, open, or semi-
open. The mechanical design of the casing provides the added classifications of axially split,
radially split, or occasionally solid. It is not unusual, then, to hear a pump referred to as a
vertical, double suction, single stage diffuser pump with closed impellers.
Vertical and horizontal refer to the position of the shaft during normal operation. The shaft is
vertical and the motor is positioned above the pump itself. This arrangement allows the pump to
be submerged in the fluid without causing water damage to the motor. Vertical pumps may be
used where floor space is limited.
Horizontal pumps have their motors beside them on the same horizontal level and their shafts
run parallel to the ground. Horizontal centrifugal pumps are further classified as 1) end
suction, 2) side suction, 3) bottom suction, and 4) top suction. Vertically mounted centrifugal
pumps are almost always bottom suction pumps.
When the suction nozzle is placed on the side of the pump with its centerline horizontal, the
pump is called a side suction pump (Figure 3). When the suction points vertically downward,
the pump is classified a bottom suction pump (Figure 4). The most common type of pump,
with its suction horizontal and its centerline coincidental with the shaft is an end suction pump
(Figure 5).
Figure 4 Down Suction Pump
Ensure the pump is filled and vented, to prevent gas binding and cavitation due to air and
gas in the pump casing.
Cooling water and lubricating systems should be verified operable before starting the
pump. This check should include checking lubricating oil levels and flow, and cooling
water temperatures to the bearings. Introduce cooling water to pump bearings and
lubricating oil systems slowly.
Bearings should be near normal operating temperature when the pump is started.
The suction valve of a centrifugal pump must be verified open prior to pump start, to ensure an
adequate flowpath to the pump impeller. The suction valve must remain open while the pump is
running. The discharge valve should be closed when a centrifugal pump is started, to prevent
excessive starting torque and load on the motor. During pump start, observe pump motor current
to ensure it drops to the normal operating range after the starting surge.
The discharge valve should not be closed for an extended period unless minimum (recirculating)
flow is verified adequate. Some recirculating flow is necessary to prevent overheating the pump.
A centrifugal pump should not be operated until it is filled with fluid. If the pump is run without
fluid, there is danger of damage to liquid lubricated internal parts. Several methods can be used
to ensure that all the air is vented from the pump. The process of filling the pump with liquid
and evacuating all gases is called priming. Adequate priming can normally be assured once a
solid stream of fluid issues from the vent valve. In some systems, automatic priming is
accomplished utilizing a priming pump controlled by a float switch. Priming the pump and
venting the casing during system startup will prevent gas binding. Once the pump is started, the
occurrence of gas binding would be indicated by low flow and low discharge pressure readings.
Additionally, the motor would be drawing minimum current.
The ball bearings should be supplied with the proper grade of lubricant and oil lubricated
bearings should be filled to the overflow level.
Cooling water should be introduced carefully to pump bearings and lubricating oil. Use only
sufficient water to keep the lubricant at a safe working temperature. Before starting the pump,
bearing temperatures should be near ambient temperature. Prior to pump start, the main concern
is that the bearings are too cold, due to cooling water being supplied with the pump off. If
bearing temperatures are low, cooling water should be isolated until pump bearings are at normal
operating temperatures. Final inspection of all parts should be made carefully before starting the
pump. It should be possible to rotate the shaft by hand. This starts the flow of oil to the bearing
surfaces.
The pump is started with the discharge valve closed, because the pump operates at only 35-50
percent of full load when the discharge valve is closed. Pumps started with the discharge valve
open require more starting torque. But, if the liquid on the upper side of the discharge check
valve is under sufficient head, the pump can be started with the discharge valve open.
When the pump is started, the normal electrical response is high starting amps [five (5) to six (6)
times normal operating current]. This rapidly drops off to a lower equilibrium value.
Additionally, motor current is affected by system (fluid) temperature. At system startup, more
current is required to circulate the cooler (denser) fluid. After system warm-up, lower motor
current is necessary to maintain the equivalent flow rate. Overheating will result if a pump is
operated against a closed valve (dead headed) for more than a few minutes.
The smallest amount of flow that will prevent a pump from overheating is the pumps minimum
flow rating/requirement.
A split casing pump is made of two (2) or more parts fastened together and commonly referred to
as a horizontally split case pumps (Figure 7).
Figure 6 Solid Pump Casing
Gland
Seal Chamber /
Stuffing Box
Mechanical Seal
Pump Shaft
Stuffing Box
Lantern Ring
Shaft Sleeve
Numerous types of mechanical seals are available for each type and/or pump use. Refer to the
seal manufacturers detailed installation instructions for each one (1).
Packed pumps require a certain amount of leakoff to ensure the packing is lubricated and does
NOT burn up. Some, but not all packed pumps are equipped with lantern rings as illustrated in
Figure 9, as well as junk rings. Lantern rings are spaced between packing rings so that they
line up with a water supply or leakoff point in the stuffing box as indicated in Figure 9. Junk
rings are in place to prevent the packing from being extruded (pushed) into the pump case
interior.
All packed pumps will have a packing gland or gland follower (Figure 9 again) and the yellow
rings of packing in Figure 9 indicate where most of the packing compression/sealing is taking
place. It is important to count the number of packing rings before and after the lantern ring when
repacking a pump so as to get the lantern ring back where it belongs in relation to the feed hole.
2.3 Volutes and Diffusers
Volute and diffuser describes the area in which a centrifugal pump converts the kinetic energy of
the fluid into pressure.
The volute pump derives its name from the spiral-shaped casing surrounding the impeller. This
casing section collects the liquid discharged by the impeller and converts velocity energy into
pressure energy. A centrifugal pump volute increases in size from its initial point until it
encompasses the full 360 degrees around the impeller and then flares out to the final discharge
opening. The wall dividing the initial section and the discharge nozzle portion of the casing is
called the tongue of the volute or the cut-water.
In a single stage volute pump that is operating at normal capacities the forces on the impeller are
balanced, at reduced flows they are not. The amount of this force depends on pressures and
impeller size. This force can distort (bend) the shaft and cause rubbing of the impellers on the
casing. If the condition persists, the result is often a broken shaft. There are several ways
to solve this problem. One (1) is to use heavier shafts and bearings. Another way is to use a
double-volute (Figure 10), or a diffuser (Figure 11).
The double-volute design (Figure 10) consists of two (2) volutes 180 degrees apart that join at a
common discharge. This design does not eliminate the imbalance, but being 180 degrees apart,
they tend to neutralize each other.
Double Volute Wall
Impeller
Volute
Diffuser Vanes
Diffusers (Figure 11) perform the same function as volutes, converting kinetic energy into
pressure energy. It consists of a number of vanes set around the impeller. These act to further
divide the forces to lessen shaft bending. Diffusers are used mainly in high-pressure multistage
pump designs and in vertical pumps.
2.3 Impellers
The efficiency of a centrifugal pump depends upon the form of impeller used. Impeller design
depends on the application of the pump and service conditions. If the impeller of a centrifugal
pump is installed backwards or if the prime mover is rotating in reverse, pump capacity will be
reduced, and turbulence and vibration will result. Remember that impeller vanes always slap the
water. They do not dig in. A centrifugal pump will work regardless of impeller rotation, but at a
reduced capacity if the impeller is installed correctly.
Impellers are classified as 1) open, 2) semi-open, or 3) closed. Enclosed (closed) impellers are
considered to be the most efficient. Figure 12 shows the parts of a closed double suction
impeller while Figure 13 shows a single suction impeller. Open impellers (Figure 14) are
used to handle large quantities of water at low heads, such as needed for circulating water for a
condenser.
IN IN
PUMP
INLET
IN IN
CASE
OUT
CASE
WEAR IMPELLER
OUT RING
Impellers are further classified by the flow path of the fluid through the impeller. This path may
be 1) axially, 2) radially, or 3) mixed (Figure 15). Axial impellers, sometimes called propellers,
are designed to pump large quantities of water at no lifts and low heads. Their use is mainly for
drainage and irrigation.
IMPELLER SHROUDS
HUB HUB
IMPELLER SHROUDS
HUB HUB
AXIS OF ROTATION
Mixed flows impellers impart both an axial and a radial flow to the fluid. Their purpose is to
provide high flow rates at low heads, as with axial flow impellers. The radial (centrifugal) action
allows for higher suction lift.
There are various types of wear ring designs. The type used for a particular unit will depend on:
a. Impeller speed
b. Pressure differences across the joint
c. The liquid being handled
Flat rings (Figure 16) are the simplest. They provide a straight axial clearance between the
impeller and the casing. The L-type rings (Figure 17) provide tight radial clearances. The axial
clearance is larger to slow down leaking fluid as it enters the suction stream. Some L-type wear
rings (as shown here) are designed to direct the fluid into the impeller eye. These are referred to
as nozzle rings. The labyrinth type (Figure 18) wear rings function the same as labyrinth
seals do. They provide a long, unbroken path with high flow resistance to reduce the
flow.
IMPELLER
IMPELLER
WEAR RING
CASE
WEAR RING
PUMP CASE
CASE
WEAR RING
PUMP CASE
IMPELLER
IMPELLER
WEAR RING
CASE WEAR
RING
IMPELLER
In small single-suction pumps the wear rings are usually pressed into the casing. Some may be
further locked on by setscrews. Casing rings on larger units are sometimes held in place with a
flange screwed to the casing. In axially split pumps, the casing rings are just set on a pin or
tongue that projects into the casing and is used to prevent these rings from rotating.
Impeller rings are often press fit or shrink fit onto the impellers. Setscrews are used with these
fits at times to provide added strength to the fit. Other designers prefer to screw the rings on to
the impellers. Again, sometimes setscrews are added.
Centrifugal pumps are unbalanced machines. The pressures inside the pump produce forces on
both the rotating and non-rotating parts. By their design, impellers impart an axial thrust toward
the suction side. This is due to the imbalance of forces between the suction and discharge sides
of the impeller. On lower pressure units the pumps thrust bearings are able to take this load. As
pressure differences across the impeller increase the loads on the bearings increase, and a means to
balance the forces (Figure 19) must be used.
SUCTION
S PRESSURE
I
N
G
L
E
S
U
C
T
I
O
N
I
M
P
E
L
L
E
R
DISCHARGE
PRESSURE
Shaft sleeves used at specific locations are given names that reflect their purpose. For
example, a shaft sleeve is a multistage pump between two (2) impellers running through the
interstage bushing is called a distance sleeve or an interstage sleeve. Sleeves may be mounted
by:
a. A keyway and shaft nut
b. A threaded or screwed fitting
On some pumps a shaft sleeve with a threaded fitting may have a left hand thread. The thread
direction will depend on the rotation of the pump and which end of the shaft the sleeve is on. The
purpose for this is so that the frictional grip of the packing or bearing will tighten the shaft sleeve
not loosen it.
2.6 Couplings
Couplings can compensate for axial growth of the shaft and transmit torque to the impeller.
Shaft couplings can be broadly classified into two (2) groups: rigid and flexible. Rigid couplings
are used in applications where there is absolutely no possibility or room for any misalignment.
Flexible shaft couplings are more prone to selection, installation and maintenance errors.
Flexible shaft couplings can be divided into two (2) basic groups: elastomeric and non-
elastomeric.
Elastomeric couplings use either rubber or polymer elements to achieve flexibility. These
elements can either be in shear or in compression. Tire and rubber sleeve designs are elastomer
in shear couplings; jaw and pin and bushing designs are elastomer in compression couplings.
Non-elastomeric couplings use metallic elements to obtain flexibility. These can be one (1) of
two (2) types: lubricated or non-lubricated. Lubricated designs accommodate misalignment by
the sliding action of their components, hence the need for lubrication. The non-lubricated
designs accommodate misalignment through flexing. Gear, grid and chain couplings are
examples of non-elastomeric, lubricated couplings. Disc and diaphragm couplings are non-
elastomeric and non-lubricated.
Pump to driver alignment is critical to the operation of the equipment and misalignment is the
number one (1) cause of premature rotating equipment failure. The instructions/tolerances
allowed by the coupling manufactures more often times then not, way beyond the equipment
(pump and motor) manufactures recommendations for amount of misalignment.
The flexible coupling is designed to compensate for any equipment/system abnormalities such
as those found during startup or shutdown of rotating equipment. It is often the case where a
pump will be purposely aligned low to the driver (motor) in a cold state because we know the
pump is going to grow (expand) when it heats up, especially when pumping a heated liquid.
This is done so that the pump grows into alignment as it heats up rather than the alternative of
a perfect cold alignment that grows out of alignment as it heats up.
On any pumping equipment where the pump is driven by an electric motor, the motor is moved
to align to the pump for some obvious reasons. The most obvious is the rigid suction and
discharge piping. There are no such restrictions on the movement of the motor and it is therefore
the logical choice for movement.
Axial alignment is also critical especially on the larger installations where the motor is equipped
with plain Babbitt bearing with no provision for thrust containment or control. In these
situations the thrust of the coupled equipment (pump to motor) is controlled by the pumps thrust
bearing. It is imperative that on these installations, the motor is run for Mag-Center when the
coupling is NOT made up. This ensures that the motors Mag-Center and the pumps thrust are
not in a constant battle for the axial position of the rotating elements.
3.0 Equipment Preventive and Corrective Maintenance
Page 1
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
PREFACE
This Training Equipment Maintenance Training Procedure (EMP) has been designed to assist you
in meeting the requirements of Module IRI-SM-04 of the Maintenance Section Training Program.
It contains information pertaining to maintenance of the Single Stage Centrifugal Pump. This
includes purpose, precautions, limits and setpoints, procedures and references for maintaining
equipment.
You should also inspect the equipment, identifying its components and controls. Should you have
additional question about the equipment maintenance, ask your supervisor.
Page 2
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
I. Purpose............................................................................................................................... 0
II. Precautions, Limitations, and Setpoints ......................................................................... 0
III. Procedure........................................................................................................................... 0
A. Operating Procedure ........................................................................................................... 0
B. Preventive Maintenance...................................................................................................... 1
C. Corrective Maintenance ...................................................................................................... 1
Page 3
I. Purpose
This procedure provides information and guidance for the correct and safe use and
maintenance of the Single Stage Centrifugal Pump.
A. Prior to performing any work on system pumps, Lock-Out and Tag-Out the
pump/motor to be worked on.
C. Proper personal protective gear should be worn at all times when working on a pump
in place.
D. Prior to starting a centrifugal pump, ensure that the pump case is filled and vented.
E. Ensure that the pumps cooling water (if so equipped) and lubrication system are in
place and operable.
F. Ensure that the pumps suction valve (if so equipped) is open prior to starting the
pump.
III. Procedure
The following procedures provide detailed instructions for conducting routine
operations, as well as preventive and corrective maintenance on Single Stage
Centrifugal Pumps.
A. Operating Procedure
The following procedures provide detailed instructions for conducting routine
operations, as well as preventive and corrective maintenance on system centrifugal
pumps.
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__1. Check pump and motor lubrication levels (lube oil reservoir) if so equipped.
__4. Listen for any abnormal or excessive noise from the pump/motor and shut
the unit down if necessary.
__5. Check that the pumps discharge pressure is normal and all other operating
parameters are good.
__6. Before leaving the immediate area of the pump/motor check that there are
no obvious leaks coming from the pump or its associated piping.
B. Preventive Maintenance
The following steps are to be used by the equipment operator when performing
preventive maintenance on Centrifugal Pumps.
__2. On those pumps/motors so equipped, check oil levels and add oil as
needed being sure to use the recommended grade.
C. Corrective Maintenance
Follow the equipment manufacturers instructions for the repair and/or
replacement of parts. The following generalized guidelines would apply to any
equipment (pump) installation.
Page 1
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__1. Using the prescribe clearance procedure, ensure the pump is isolated from
the system by closing all suction, discharge, bypass and vent valves if so
equipped.
__2. Using the prescribed clearance procedure, ensure the motor is isolated
from the Electrical System.
__2. Remove the horizontal bolting holding the top half of the cast to the
bottom half.
__3. Using a come-along or other lifting device, carefully lift the top half of the
case off and set aside.
__4. Save the horizontal joint gasket or make note of its size (thickness).
__6. Using a come-along or other lifting device, carefully lift the rotating
element from the case and place on v-blocks or have some other way of
preventing the element from rolling around during transport to the shop.
Page 2
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__7. Remove the case wear rings from the impeller and slide them off the end
of the shaft.
Impeller
Bearing Bearing
Sleeve Nut
__9. Remove ball or roller bearings from shaft if so equipped. Do NOT discard
the old bearings until such time as new ones have been matched up.
__10. Remove the shaft sleeve nuts from each end of the shaft remembering that
one (1) will be a left hand thread and one (1) will be a right hand thread.
__11. Remove the shaft sleeves from each end of the shaft.
Page 3
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__14. Take and record sizes of bearing fits, shaft sleeve fits as well as sleeve
OD, impeller fit on shaft and bore of impeller as well as impeller wear
ring OD (90 degrees apart for roundness as well).
__15. Take and record case wear ring ID (90 degrees apart for roundness as
well) and compare to impeller wear ring OD for running clearance check.
__16. It is NOT normally necessary to replace both the impeller wear rings and
case wear rings at the same time. A judgment will need to be made based
on the condition of both, as to which one (1) will be replaced (if need be).
NOTE: Of the two (2), the impeller wear rings are the easiest to replace as
they typically require less machining than most types of case wear rings.
The following procedure covers the replacement of impeller wear rings
__1. Remove the grub screws from the impeller to impeller wear ring fit, if so
equipped. Some wear rings are staked in place in which case the stakes
will need to be ground or machined out.
Page 4
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__2. Once the grub screws are removed, the impeller wear rings can be
removed by either machining them off or heating them until they expand
enough to be taken off by hand.
__3. At this point the impeller wear ring fit to impeller bore should be checked
for concentricity and roundness.
__4. New impeller wear rings are then machined (bored) for a shrink fit to the
impeller wear ring fit allowing .0002 to .0005 per inch of diameter for the
interference (shrink) fit. The OD of the impeller wear rings are left big for
final machining when installed on the impeller.
__5. Heat to expand the impeller wear rings and place them on the impeller.
__6. Install grub screws axially between the impeller and impeller wear ring fit
(Figure 2).
Page 5
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Impeller
Grub Screws
__7. Machine impeller wear ring OD for required running clearance to the case
wear rings.
__4. At this point check the run out of the shaft to ensure that the impeller,
sleeve and sleeve nut axial faces are perpendicular to their bores.
Page 6
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Pump Reassembly
We are assuming that the pump case has been prepared for reassembly with clean
flanges and a new gasket has been made to fit the case.
__1. Transport the rotating element with case wear rings installed to the pump
installation site and install the rotating element in the lower pump case
making sure to fit the case wear rings in their proper location.
__3. Rotate the pump element by hand to ensure its freedom of movement.
__4. Install the pumps upper case half with a new gasket of the same thickness
as the old one (1).
__5. Rotate the pump element by hand to ensure its freedom of movement.
__6. Install the horizontal bolting and using the correct tightening sequence,
tighten the bolts.
__7. Rotate the pump element by hand to ensure its freedom of movement.
Page 7
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
__8. Check the alignment of the pump to the motor based on the manufactures
recommendations and move the motor if necessary to align.
__9. Make up the pump to motor coupling and rotate the pump and motor by
hand to ensure their freedom of movement.
__10. Witness the running of the pump and motor by operations to ensure there
are no problems with the pump.
Replacement of Bearings
Replacement of just the pump bearings involves an abbreviated version of the
complete work scope above.
Page 8
SINGLE STAGE CENTRIFUGAL PUMP
IRI-SM-04JPM
TRAINING EQUIPMENT JOB PERFORMANCE MEASURE
Name: __________________________________
________________________________________ ____________________
(Supervisors Signature) (Date)
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
References:
Training Module IRI-SM-04
Materials Needed:
Pencil and Clipboard
Equipment Maintenance Description Single Stage Centrifugal Pump IRI-SM-06-EMD
Equipment Maintenance Procedure Single Stage Centrifugal Pump IRI-SM-06-EMP
Associated Maintenance Checklist, Charts, Parts List, Technical Manuals
Safety/Environmental:
Wear hard hats, safety glasses, safety toe shoe, and ear plugs as required.
Discuss environmental hazards associated with performing maintenance of the equipment.
Discuss any safety precaution that must be observed while performing the procedure.
Note: Always
observe all plant safety rules in accordance with Safety and Health Procedures and all
Federal, State and/or Local OSHA Standards.
Page 1
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Part B: Controls/Breakers
1. Control Breaker
Page 2
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
1. Prior to performing any work on system pumps, Lock-Out and Tag-Out the pump/motor to
be worked on.
2. Ensure that the system involved is depressurized and/or drained/isolated prior to removing a
pump from a system line.
3. Proper personal protective gear should be worn at all times when working on a pump in place.
4. Prior to starting a centrifugal pump, ensure that the pump case is filled and vented.
5. Ensure that the pumps cooling water (if so equipped) and lubrication system are in place and
operable.
6. Ensure that the pumps suction valve (if so equipped) is open prior to starting the pump.
Operating Procedure
1. Check pump and motor lubrication levels (lube oil reservoir) if so equipped.
2. Open the pumps suction valve if so equipped.
3. Start the pump/motor by depressing its START/RUN pushbutton.
4. Listen for any abnormal or excessive noise from the pump/motor and shut the unit down if
necessary.
5. Check that the pumps discharge pressure is normal and all other operating parameters are
good.
6. Before leaving the immediate area of the pump/motor check that there are no obvious leaks
coming from the pump or its associated piping.
Page 3
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Lubrication
1. On those pumps/motors so equipped, grease the pump/motor bearings with Grade 2 general-
purpose grease.
2. On those pumps/motors so equipped, check oil levels and add oil as needed being sure to use
the recommended grade.
1. Using the prescribe clearance procedure, ensure the pump is isolated from the system by
closing all suction, discharge, bypass and vent valves if so equipped.
2. Using the prescribe clearance procedure, ensure the motor is isolated from the electrical
system.
Page 4
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
6. Using a come-along or other lifting device, carefully lift the rotating element from the case
and place on v-blocks or have some other way of preventing the element from rolling
around during transport to the shop.
7. Remove the case wear rings from the impeller and slide them off the end of the shaft.
8. Depending on the reason for disassemble (operational problem); take as found run out
(dial indicator) readings of the element prior to further disassembly.
9. Remove ball or roller bearings from shaft if so equipped. Do NOT discard the old bearings
until such time as new ones have been matched up.
10. Remove the shaft sleeve nuts from each end of the shaft remembering that one will be a left
hand thread and one will be a right hand thread.
11. Remove the shaft sleeves from each end of the shaft.
12. Remove the impeller from the shaft.
13. Take as found run out readings of the bare shaft.
14. Take and record sizes of bearing fits, shaft sleeve fits as well as sleeve OD, impeller fit on
shaft and bore of impeller as well as impeller wear ring OD (90 degrees apart for roundness
as well).
15. Take and record case wear ring ID (90 degrees apart for roundness as well) and compare to
impeller wear ring OD for running clearance check.
16. It is NOT normally necessary to replace both the impeller wear rings and case wear rings at
the same time. A judgment will need to be made based on the condition of both, as to which
one will be replaced (if need be).
Page 5
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Pump Reassembly
1. Transport the rotating element, with case wear rings installed, to the pump installation site
and install the rotating element in the lower pump case making sure to fit the case wear
rings in their proper location.
2. Install the upper half bearing housing if so equipped.
3. Rotate the pump element by hand to ensure its freedom of movement.
4. Install the pumps upper case half with a new gasket of the same thickness as the old one.
5. Rotate the pump element by hand to ensure its freedom of movement.
6. Install the horizontal bolting and using the correct tightening sequence, tighten the bolts.
7. Rotate the pump element by hand to ensure its freedom of movement.
8. Check the alignment of the pump to the motor based on the manufactures recommendations
and move the motor if necessary to align.
9. Make up the pump to motor coupling and rotate the pump and motor by hand to ensure their
freedom of movement.
10. Witness the running of the pump and motor by operations to ensure there are no problems
with the pump.
Page 6
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
Performed all aspects of the JPM using safe operating practices and following plant safety and
environmental procedures.
Page 7
SINGLE STAGE CENTRIFUGAL PUMP
IRI-SM-04Q
TRAINING EQUIPMENT JOB PERFORMANCE MEASURE
TEST QUESTIONS
2. (IRI-SM-06-QB) Prior to starting a centrifugal pump it should be checked to ensure that the
____________.
A. packing is tight enough
B. case is filled with fluid
C. packing is not too tight
D. pump base is bolted down
3. (IRI-SM-06-QB) The rings of packing closest to _____________ see the most compression or
do most of the sealing.
A. the gland follower
B. lantern ring
C. junk ring
D. impeller
4. (IRI-SM-06-QB) Axial thrust forces on a single suction impeller are __________ those on a
double suction impeller.
A. less than
B. greater than
C. equal to
D. not of any consequence
5. (IRI-SM-06-QB) The type of wear ring used on a pump so equipped will depend on the
speed, pressure differences (suction and discharge) and _______________.
A. mounting of the pump
B. process temperature
C. location of the pump
D. the type of liquid being pumped
6. (IRI-SM-06-QB) Impellers are further classified by the direction of flow through them being
either radial, _________ or axial.
A. propeller
B. mixed
C. static
D. conventional
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
7. (IRI-SM-06-QB) Wear rings are used on pump impellers and cases to allow for __________.
A. easy reestablishment of running clearances
B. misalignment of rotating elements
C. the use of dissimilar metals
D. pump joint leakage
9. (IRI-SM-06-QB) The wear rings on a centrifugal pump impeller are attached/installed with a
shrink fir and ______________.
A. radial grub screws
B. axial grub screws
C. permatex bond
D. silver solder
10. (IRI-SM-06-QB) The OD of the impeller wear ring needs to be machined ___________.
A. concentric to the wear ring ID
B. concentric to the impeller bore
C. perpendicular to the impeller bore
D. parallel to the impeller bore
11. (IRI-SM-06-QB) The different types of wear rings are flat, L shaped and
_________________.
A. staggered
B. labyrinth
C. convoluted
D. split
Page 1
Industrial Resources, Inc. Single Stage Centrifugal Pump
Mechanical Maintenance IRI-SM-06-EMP
13. (IRI-SM-06-QB) The area where the packing is located on a packed pump is referred to as
___________.
A. the stuffing box
B. the seal chamber
C. the packing chamber
D. the seal box
14. (IRI-SM-06-QB) There are several ways to solve a bending shaft problem, one (1) would be to
___________.
A. realign the pump
B. replace the pump
C. use a double volute pump case
D. redo the pump base plate
15. (IRI-SM-06-QB) The most common type of single stage centrifugal pump is
________________.
A. bottom suction pump
B. an end suction pump
C. side suction pump
D. top suction pump
Page 2