MV Series
Bulletin SS02016 Issue/Rev. 1.7 (9/14)
We put you first.
And keep you ahead.
FEATURES
Titanium swept-front helical rotor swept front
design allows for increased meter factor stability
while minimizing the effects of containments or
debris.
Stainless steel interchangeable measuring
element provides for ease of serviceability while
providing corrosion-free service.
Reynolds number is calculated using the following
Tungsten carbide bearings provide long ser-
equations:
vice life and dependability on a wide variety of
products. 2214 x Flow Ratemax
Remax =
NACE Compliance to MR0175/ISO 15126-1. Meter Size x Viscmin
The MTR is then determined by using the ratio of the Heating Oil Diesel
K-Factor
LPG
maximum Reynolds (Remax) number over the minimum
Reynolds (Remin) number.
20.0 10"
m3/h 199 1,990 116
15.0 BPH 1,900 19,000 11.1
12"
m3/h 302 3,020 70
10.0
BPH 2,700 27,000 6
16"
5.0 m3/h 429 4,290 38
0.0
1,000 10,000 100,000 1,000,000
MATERIAL SPECIFICATIONS
Reynolds Number
End Connections*
Class 150, 300, 600
Typical Accuracy Curve for 8" MVTM ASME B16.5, 125-250 AARH finish raised face (RF) flanges
Accuracy over the complete Reynolds number range tested *Consult factory for higher working pressure or other types of flanges.
on 13 cSt product:
43.0
(Pulses/Barrel)
42.8
42.9
42.7 ANSI Carbon Steel Flanges
K-FactorK-Factor
42.8
42.6 150 285 (1,965)
42.7
42.5 300 740 (5,102)
42.610000 100000 1000000 600 1,480 (10,205)
Reynolds Number (Re)
42.5
10000 100000 1000000
43.0
with 24" Standoff -46C to 107C -40C to 107C
42.9
(Pulses/barrel)
43.0
42.8
42.9
Pulse Output
42.7
See PA-6 Preamplifier specification bulletin SS02012 or
K-FactorK-Factor
42.8
42.6
42.7
42.5
UPCC specification bulletin SS02017.
0 1000 2000 3000 4000 5000 6000 7000 8000
42.6
TESTING
Dynamic Testing
Dynamic testing enables a meter's performance to be simulated over a wide flow and viscosity operating range.
Each meter will be tested over the entire Reynolds number range of the application by utilizing a multiple product,
high accuracy test.
Reynolds Number
Electrical Characteristics
Effective Series Resistance (Re): 4,700 (10%).
Effective Series Inductance (Le): 6H @ 100 Hz.
Minimum Open Circuit Voltage (Vo): 75 millivolts p/p at
minimum flow rate.
Maximum Transmission Distance: 2,000 ft (610 m) using
#20 AWG two-conductor, shielded cable.
1 2 3 4 5 6 7 8 9 10 11
K 2 v F A L U 1 A 0 0
2 Two (2) pickup bosses are standard for all sizes. Additional pickup coils and preamps, can be added if required.
3 The AccuLERT also provides dual channel preamplification and online diagnostics.
4 PED required for all European countries; equipment must be manufactured by Ellerbek, Germany facility.
1" NPT B
Dimensions inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective
engineering drawings.
Note Meter weights by flange class with one pickup coil and explosion-proof box. Add 5 lb (2.3 kg) for each additional pickup coil and
explosion-proof box.
5 Add 24" for a standoff when using a preamplifier for temperatures 158F to 225F (70C to 107C).
USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
www.fmctechnologies.com/measurementsolutions Suite 100 Regentstrasse 1
Houston, Texas 77067 USA 25474 Ellerbek, Germany
2014 FMC Technologies. All rights reserved. SS02016 Issue/Rev. 1.7 (9/14) P:+1 281.260.2190 P:+49 4101.304.0
6