_INVDRT081_Reset_Free (1/3)

INVDRT
081 [User-set allocation] Error Reset: _INVDRT081_Reset_Free
Basic Resets an error for the Inverter whose Local Memory is allocated to a User-set memory area of the CPU Unit
function via DeviceNet.
Symbol Always ON _INVDRT081_Reset_Free
(BOOL) (BOOL)
EN ENO
(WORD) (BOOL) (May be omitted)
OUT Area ID OutAreaID Done Error reset completed
(INT) (BOOL)
OUT Area No OutAreaNo Error Error end
(WORD) (WORD) Error number
IN Area ID InAreaID ErrorID (May be omitted)
(INT)
IN Area No InAreaNo
(BOOL)
Start Execute

File name Lib\FBL\omronlib\Inverter\INVRT\Dnet\_INVDRT081_Reset10.cxf


Applicable Applicable Master Unit CS1W-DRM21(-V1), CJ1W-DRM21
models Applicable Slave Unit 3G3MV Series, 3G3RV Series
(Inverters) CIMR-V7AZ, CIMR-F7Z, CIMR-E7Z (Sold by OYMC)
CPU Unit CS1*-CPU**H Unit version 3.0 or higher
CJ1*-CPU**H Unit version 3.0 or higher
CJ1M-CPU** Unit version 3.0 or higher
CP1H
CX-Programmer Version 5.0 or higher
Conditions  Inverter and DeviceNet Master unit Settings should be required a condition below.
for usage The followings are necessary for the Inverter connected to DeviceNet.
It must use standard remote I/O. (This is the default setting for the 3G3xV-PDRT2 DeviceNet
Communications Unit.) (The FB can not be used if the other remote I/O function is set by the configurator)

The allocated size should be used 4 types by using 2 channels for both OUT and IN area.
(For using the standard remote I/O settings)

For using the FB, the remote I/O area first address of Slave unit allocated to DeviceNet Master Unit should be
required. For details, refer to the manual listed in the Related manuals below.

Caution: If Fixed Allocation is used, [Fixed Allocation] Reset Inverter Error: (_INVDRT080_Reset) will be
ready.
If User-set allocations uses DM area or configurator, make sure to use the address for setting to
input variable. If the address is different from the specified address, commands will be sent to the
slave with an unintended slave No., which may cause the system or machine to operate in an
unexpected way.
Function The error reset command is operated for the Inverter specified by Master Unit No. (MasterUnitNo) and Inverter
description Slave Address (NodeNo).
The error reset command is always ON while Start (Execute) remains ON.
If Master Unit No. (MasterUnitNo) and Inverter Slave Address (NodeNo) is changed, the appricable unit will be
replaced while Start (Execute) remains ON.
If Start (Execute) is ON and the error is OFF, Error reset completed (Done) will be ON.
If Start (Execute) is OFF, Error reset completed (Done) will be OFF.
FB Inverter uses 2 channels for both OUT and IN area, so 4 types should be used for the allocated size.
precautions This Function Block is processed over several cycles.
Timechart
Start(Execute) ON
OFF

Normal end (Done) ON


or OFF
Error end (Error)
Error Reset completed.

EN input Connect the EN input to the Always ON Flag (P_On).


condition
Restrictions Always use the Always ON Flag for EN.
Input If the input variables are out of range, the ENO Flag will turn OFF and the FB will not be processed.
variables
_INVDRT081_Reset_Free (2/3)

Application When bit A is turned ON, operation is started for Inverter 20 allocated to OUT area first address CIO100 and IN
example area first address CIO200, which connected to the DeviceNet Unit with a unit number of 10.
&10

CPU DRM
Unit No.:10

Inverter DRT2:20
OUT Area CIO100 to 101
IN Area CIO200 to 201
DRT2 20

Inverter
_INVDRT081_Reset_Free
ON(P_On) (BOOL) (BOOL)
EN ENO
OUT Area ID (WORD) (BOOL) Error reset completed
P_CIO OutAreaID Done Bit B
OUT Area No (INT) (BOOL) Error end
&100 OutAreaNo Error
IN Area ID (WORD) (WORD) Error number
P_CIO InAreaID ErrorID
IN Area No (INT)
&200 InAreaNo
Start (BOOL)
Bit A Execute

Related SYSDRIVE 3G3MV Multi-function Compact Inverters Users Manual (I527)


manuals SYSDRIVE 3G3RV High-function General-purpose Inverters Users Manual (I532)
SYSDRIVE DeviceNet Communications Unit/Card User's Manual (I539)
CS/CJ Series DeviceNet Units Operation Manual (W380)
Section 3 Allocated CIO and DM Words
Section 4 Remote I/O Master Communications
CIMR-F7Z Users Manual (YEG-TOE-S616-55.1-OY)
CIMR-E7Z Users Manual (YEG-TOE-S616-56.1-OY)
_INVDRT081_Reset_Free (3/3)

 Variable Tables
Input Variables
Name Variable name Data type Default Range Description
EN EN BOOL 1 (ON): FB started
0 (OFF): FB not started.
OUT Area ID OutAreaID WORD #0082 See P_CIO (#00B0): CIO Area
description P_WR (#00B1): Work Area
P_HR (#00B2): Holding Area
P_DM (#0082): DM Area
P_EM0 (#0050) to P_EMC (#005C):
EM Area bank 0 to 1C
OUT Area No. OutAreaNo INT #0000 See The range depends on the value of the OUT
description Area ID (OutAreaID)
Specified CIO area: &0 to &6142
Specified WR area: &0 to &510
Specified HR area: &0 to &510
Specified DM area: &0 to &32766
Specified EM area: &0 to &32766
IN Area ID InAreaID WORD #0082 See Same as OUT Area ID (AreaID)
description
IN Area No. InAreaNo INT #0000 See Same as OUT Area No. (AreaNo)
description
Start Execute BOOL 0(OFF) 1 (ON): Aborts Inverter operation.

Output Variables
Name Variable name Data type Range Description
ENO ENO BOOL 1 (ON): FB processed normally.
(May be omitted.) 0 (OFF): FB not processed or ended with an error.
Error reset Done BOOL 0 (OFF): Other status
completed 1 (ON): Deceleration stop completed flag
Error flag Error BOOL 0 (OFF): Other status
1 (ON): Error in FB
Error number ErrorID WORD #0000: No error
(May be omitted.)

Version History
Version Date Contents
1.00 2005.7. Original production

Note
This manual is a reference that explains the function block functions.
It does not explain the operational limitations of Units, components, or combinations of Units and components. Always read
and understand the Operation Manuals for the systems Units and other components before using them.