Professional Documents
Culture Documents
"ﺍﻟﻬﻧﺩﺳﻪ ﺍﻟﻛﻬﺭﺑﻳﻪ" ﻋﻠﻡ ﻭﻓﻥ
ﺍﻟﻣﺷﺎﺭﻛﺎﺕ ﺍﻟﺷﺎﺋﻌﺔ
. Show all postsﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔShowing posts with label
Star/Delta Starter
ﻟﻣﺣﻭﻻﺕ ﺍﻟﺗﻭﺯﻳﻊ Nameplate ﺷﺭﺡ ﺍﻟﺑﻳﺎﻧﺎﺕ ﺍﻟﻭﺭﺍﺩﻩ ﻓﻰ ﺍﻟـ
Currentﻣﺣﻭﻻﺕ ﺍﻟﺗﻳﺎﺭ
transformers
ﻁﺭﻕ ﺑﺩء ﺗﺷﻐﻳﻝ ﺍﻟﻣﺣﺭﻛﺎﺕ ﺍﻟﺣﺛﻳﻪ
Starting methods of Induction
motors
ﺃﻧﻭﺍﻉ ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ ﻭﺍﻷﺑﺭﺍﺝ
ﺍﻳﻬﻣﺎ ﺍﻓﺿﻝ ﻧﻅﺎﻡ 220 ﻓﻭﻟﺕ ﻭﺗﺭﺩﺩ50
ﻫﺭﺗﺯ ﺃﻡ ﻧﻅﺎﻡ 110 ﻓﻭﻟﺕ ﻭ ﺗﺭﺩﺩ60
ﻫﺭﺗﺯ ؟
ABOUT
TOTAL REVIEWS
7 5 8 6 9
ﺃﻗﺳﺎﻡ ﺍﻟﻣﺩﻭﻧﺔ
ﺁﻻﺕ ﻛﻬﺭﺑﻳﺔ
ﺷﺭﺡ ﺍﻟﺑﻳﺎﻧﺎﺕ ﺍﻟﻭﺭﺍﺩﻩ ﻓﻰ ﺍﻟـ Nameplate ﻟﻣﺣﻭﻻﺕ ﺍﻟﺗﻭﺯﻳﻊ ﺍﻟﺭﺋﻳﺳﻳﺔ
ﻳﺟﺏ ﺃﻥ ﻳﺣﺗﻭﻯ ﻛﻝ ﻣﺣﻭﻝ ﻋﻠﻰ ﻟﻭﺣﺔ ﺑﻳﺎﻧﺎﺕ ﺑﺣﻳﺙ ﻳﺳﻬﻝ ﺍﻟﺗﻌﺎﻣﻝ ﻣﻊ ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ ﺍﻟﻛﻬﺭﺑﻰ
ﺷﺑﻛﺎﺕ ﻛﻬﺭﺑﻳﻪ
ﺍﻟﻣﺣﻭﻝ. ﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔ
ﻭﺍﻟﺑﻳﺎﻧﺎﺕ ﺍﻟﻣﻭﺟﻭﺩﺓ ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﺑﻳﺎﻧﺎﺕ ﻛﺎﻟﺗﺎﻟﻰ:
ﻣﺩﻭﻧﺎﺕ ﺻﺩﻳﻘﺔ
ﺍﺳﻡ ﺍﻟﺷﺭﻛﺔ ﺍﻟﻣﻧﺗﺟﺔ.
ﺳﻧﺔ ﺍﻟﺻﻧﻊ Manfact. Date............................ ADS 468X60PX
ﺍﻟﺗﺭﺩﺩFrequency.....................................
ABOUT ME
ﺍﻟﻘﺩﺭﺓPower Rated .................................... eng alaa
View my complete profile
ﺟﻬﺩ ﺍﻟﻣﻌﺎﻭﻗﺔImpedance voltage .........................
ﺯﻣﻥ ﺍﻟﻘﺻﺭ. Short circuit time ..............................
FOLLOWERS
…http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8 1/6
6/24/2015 ﺍﻟﻬﻧﺩﺳﻪ ﺍﻟﻛﻬﺭﺑﻳﻪ" ﻋﻠﻡ ﻭﻓﻥ" :ﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔ
Join this site
ﺍﻟﻭﺯﻥ ﺍﻟﻛﻠﻰTotal weight ............................ with Google Friend Connect
»Members (35) More
ﻭﺯﻥ ﺍﻟﺯﻳﺕOil weight ...............................
ﻁﺭﻳﻘﺔ ﺍﻟﺗﺑﺭﻳﺩType of cooling .........................
ﺍﻟﺗﻳﺎﺭ ﺍﻟﻣﻘﻧﻥRated current ..........................
ﺍﻟﺟﻬﺩ ﺍﻟﻣﻘﻧﻥ) ﻋﻧﺩ ﻛﻝ ﻧﻘﻁﺔ ﻣﻥ ﻧﻘﺎﻁ ﻣﻐﻳﺭ ﺍﻟﺟﻬﺩRated voltag (
ﻫﺫﻩ ﺻﻭﺭﻩ ﻟﻠﻭﺣﺔ ﺑﻳﺎﻧﺎﺕ ﻣﺣﻭﻝ ﺗﻭﺯﻳﻊ
Already a member? Sign in
ﺃﺭﺷﻳﻑ ﺍﻟﻣﺩﻭﻧﺔ
)▼ 2013 (12
)▼ October (11
Startingﻁﺭﻕ ﺑﺩء ﺗﺷﻐﻳﻝ ﺍﻟﻣﺣﺭﻛﺎﺕ ﺍﻟﺣﺛﻳﻪ
methods of...
Star/Delta Starter
Soft Startersﺃﺟﻬﺯﺓ ﺍﻟﺑﺩء ﺍﻟﻧﺎﻋﻡ
Current transformersﻣﺣﻭﻻﺕ ﺍﻟﺗﻳﺎﺭ
ﺍﻳﻬﻣﺎ ﺍﻓﺿﻝ ﻧﻅﺎﻡ 220 ﻓﻭﻟﺕ ﻭﺗﺭﺩﺩ 50 ﻫﺭﺗﺯ ﺃﻡ ﻧﻅﺎﻡ
110...
ﻟﻣﺣﻭﻻﺕ Nameplate ﺷﺭﺡ ﺍﻟﺑﻳﺎﻧﺎﺕ ﺍﻟﻭﺭﺍﺩﻩ ﻓﻰ ﺍﻟـ
...ﺍﻟﺗﻭ
) (Induction motor ﻣﺎﺫﺍ ﻳﺣﺩﺙ ﻟﻠﻣﺣﺭﻙ ﺍﻟﺣﺛﻰ
...ﺇﺫﺍ ﺍﻧﺧﻑ
ﺍﻟﻣﻣﻳﺯﺍﺕ ﻭﺍﻟﻌﻳﻭﺏ ﻟﻼﻧﻭﺍﻉ ﺍﻟﻣﺧﺗﻠﻔﺔ ﻣﻥ ﺍﻟﻣﺣﺭﻛﺎﺕ
...ﺍﻟﻛﻪ
ﻭﺍﻟﺷﻛﻝ ﺍﻟﺗﺎﻟﻰ ﻫﻭﺷﻛﻝ ﺗﺧﻁﻳﻁﻰ ﻳﻭﺿﺢ ﻟﻭﺣﺔ ﺑﻳﺎﻧﺎﺕ ﻣﺣﻭﻝ ﺗﻭﺯﻳﻊ
Lightning Arresrtorﻣﺎﻧﻌﺔ ﺍﻟﺻﻭﺍﻋﻕ
ﺃﻧﻭﺍﻉ ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ ﻭﺍﻷﺑﺭﺍﺝ
ﺃﻧﻭﺍﻉ ﺍﻟﻌﻭﺍﺯﻝ ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻓﻰ ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ ﺍﻟﻛﻬﺭﺑﻰ
)► September (1
FEATURED POSTS
BANNER AD
468X60 BANNER AD
SOCIAL ICONS
PAGES
ﺍﻟﺻﻔﺣﺔ ﺍﻟﺭﺋﻳﺳﻳﺔ
============================== ﻓﻬﺭﺱ ﺍﻟﻣﺩﻭﻧﺔ
1ﺍﻟﻘﺩﺭﺓ: Power Rated ﻋﻥ ﺍﻟﻣﺩﻭﻧﺔ
S = 1.732 *VL *IL KV.A
ﺍﺿﺎﻓﺎﺕ ﺑﻠﻭﺟﺭ
ﺑﺎﻟﻧﺳﺑﺔ ﻟﻣﺣﻭﻻﺕ ﺍﻟﺗﻭﺯﻳﻊ ﺗﺗﺭﺍﻭﺡ ﺍﻟﻘﺩﺭﺓ ﺑﻳﻥ( 2500kva to 25)
ﻭﻳﺗﻡ ﺗﺻﻣﻳﻡ ﺍﻟﻣﺣﻭﻝ ﻋﻠﻰ ﺃﺳﺎﺱ ﺍﻟﻘﺩﺭﺓ ﺍﻟﻅﺎﻫﺭﻳﺔ( S ) ﻗﻭﺍﻟﺏ ﺑﻠﻭﺟﺭ
=============================== ﺃﺩﺳﻧﺱ
2ﺯﻣﻥ ﺍﻟﻘﺻﺭ( Short circuit time )
ﻣﺠﺎﻻﺕ ﺍﻟﻬﻨﺪﺳﻪ ﺍﻟﻜﻬﺮﺑﻴﻪ ﻫﻨﺎ ﻧﻨﺎﻗﺶ ﻣﻮﺿﻮﻋﺎﺕ ﻣﺘﻨﻮﻋﻪ ﺗﺘﻌﻠﻖ ﺑﻤﺨﺘﻠﻒ
ﻭﻫﻭ ﺃﻗﺻﻰ ﻓﺗﺭﺓ ﺯﻣﻧﻳﺔ ﻳﻣﻛﻥ ﺃﻥ ﻳﺗﺣﻣﻠﻬﺎ ﺍﻟﻣﺣﻭﻝ ﻓﻰ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﻗﺻﺭ
…http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8 2/6
6/24/2015 ﺍﻟﻬﻧﺩﺳﻪ ﺍﻟﻛﻬﺭﺑﻳﻪ" ﻋﻠﻡ ﻭﻓﻥ" :ﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔ
SUBSCRIBE TO
)ﺛﻼﺛﺔ ﺃﻭﺟﻪ ﻣﻊ ﺍﻷﺭﺿﻰ( ﻋﻠﻰ ﺍﻟﻣﺣﻭﻝ. Posts
ﻭﻫﺫﺍ ﺍﻟﺟﺩﻭﻝ ﻳﺑﻳﻥ ﺯﻣﻥ ﺍﻟﻘﺻﺭ ﻟﻣﺣﻭﻻﺕ ﺫﺍﺕ ﻗﺩﺭﺕ ﻣﺧﺗﻠﻔﻪ All Comments
Transformer KV.A …. Short Circuit withstand
SOCIAL ICONS
Duration
Up to 630 KV.A …………………. 2 sec SEARCH BLOG
Search
Above 630 up to 2000 KV.A .............…….. 3 sec
Above 2000 KV.A ………….…….. 4 sec BLOG ARCHIVE
=============================== )▼ 2013 (12
)▼ October (11
3ﺟﻬﺩ ﺍﻟﻣﻌﺎﻭﻗﺔ:( Impedance Voltage) V%
ﻁﺭﻕ ﺑﺩء ﺗﺷﻐﻳﻝ
ﻭﻳﺳﻣﻰ ﺃﻳﺿﺎ ﺍﻟـPercentage Impedance ﺍﻟﻣﺣﺭﻛﺎﺕ
ﺍﻟﺣﺛﻳﻪ
ﺗﻌﺭﻳﻑ ﺟﻬﺩ ﺍﻟﻣﻌﺎﻭﻗﺔ Impedance voltage ﺃﻭ ﺍﻟـPercentage Starting
methods
Impedance of...
Star/Delta
ﻫﻭ ﻗﻳﻣﺔ ﺍﻟﺟﻬﺩ ﺍﻟﺫﻯ ﻳﺳﻠﻁ ﻋﻠﻰ ﺍﻟﻣﻠﻑ ﺍﻷﺑﺗﺩﺍﺋﻰ ﻭ ﻳﻣﺭﺭ ﻗﻳﻣﺔ ﺍﻟﺗﻳﺎﺭ ﺍﻟﻣﻘﻧﻥ Starter
(ﺗﻳﺎﺭ ﺍﻟﺣﻣﻝ ﺍﻟﻛﺎﻣﻝ( ﻟﻠﻣﺣﻭﻝ ﻓﻰ ﺣﺎﻟﺔ ﻭﺟﻭﺩ ﻗﺻﺭ ﻋﻠﻰ ﺍﻟﻣﻠﻑ ﺍﻟﺛﺎﻧﻭﻯ ﺃﺟﻬﺯﺓ ﺍﻟﺑﺩء ﺍﻟﻧﺎﻋﻡ
Soft
ﻣﻘﺳﻭﻣﺎ ﻋﻠﻰ ﻗﻳﻣﺔ ﺍﻟﺟﻬﺩ ﺍﻟﻣﻘﻧﻥ ﻟﻠﻣﻠﻑ ﺍﻷﺑﺗﺩﺍﺋﻰ ﻣﺿﺭﻭﺑﺎ ﻓﻰ100 Starters
ﻣﺣﻭﻻﺕ ﺍﻟﺗﻳﺎﺭ
Current
transforme
Z % = (Vpsc / Vr) X 100 rs
Z % = Impedance voltage ﺍﻳﻬﻣﺎ ﺍﻓﺿﻝ ﻧﻅﺎﻡ
220ﻓﻭﻟﺕ
ﻭﺗﺭﺩﺩ50
ﻫﺭﺗﺯ ﺃﻡ ﻧﻅﺎﻡ
= Vpscﺟﻬﺩ ﺍﻟﻣﻠﻑ ﺍﻷﺑﺗﺩﺍﺋﻰ ﻓﻰ ﺣﺎﻟﺔ ﺍﻟﻘﺻﺭ ﻋﻠﻰ ﺍﻟﺛﺎﻧﻭﻯ 110...
ﺷﺭﺡ ﺍﻟﺑﻳﺎﻧﺎﺕ
= Vrﺍﻟﺟﻬﺩ ﺍﻟﻣﻘﻧﻥ ﻟﻠﻣﻠﻑ ﺍﻷﺑﺗﺩﺍﺋﻰ ﺍﻟﻭﺭﺍﺩﻩ ﻓﻰ ﺍﻟـ
Nameplate
...ﻟﻣﺣﻭﻻﺕ ﺍﻟﺗﻭ
ﻭﻳﺗﻡ ﺗﺣﺩﻳﺩ ﻗﻳﻣﺔ ﺍﻟـ Impedance voltage ﺑﺈﺟﺭﺍء ﺇﺧﺗﺑﺎﺭ ﻣﺎﺫﺍ ﻳﺣﺩﺙ ﻟﻠﻣﺣﺭﻙ
ﺍﻟﺣﺛﻰ
Short circuit Testﻟﻠﻣﺣﻭﻝ ﺣﻳﺙ ﻳﺗﻡ ﻋﻣﻝ ﻗﺻﺭshort circuit (Induction
ﺇﺫﺍmotor )
ﻋﻠﻰ ﺍﻟﻣﻠﻑ ﺍﻟﺛﺎﻧﻭﻯ ﻟﻠﻣﺣﻭﻝ 3) ﻓﺎﺯﺍﺕ ( ﺛﻡ ﻳﺗﻡ ﺗﺳﻠﻳﻁ ﺟﻬﺩ ﻋﻠﻰ ﺍﻟﻣﻠﻑ ...ﺍﻧﺧﻑ
ﺍﻟﻣﻣﻳﺯﺍﺕ ﻭﺍﻟﻌﻳﻭﺏ
ﺍﻹﺑﺗﺩﺍﺋﻰ ﻛﻧﺳﺑﻪ ﻣﻥ ﺍﻟـ Rated Voltage ﺣﻳﺙ ﻳﺗﻡ ﺯﻳﺎﺩﺓ ﻫﺫﺍ ﺍﻟﺟﻬﺩ ﻟﻼﻧﻭﺍﻉ ﺍﻟﻣﺧﺗﻠﻔﺔ
ﻣﻥ ﺍﻟﻣﺣﺭﻛﺎﺕ
ﺗﺩﺭﻳﺟﻳﺎ ﻣﻥ ﺍﻟﺻﻔﺭ ﺇﻟﻰ ﺃﻥ ﻳﻣﺭ ﺍﻟﺗﻳﺎﺭ ﺍﻟﻣﻘﻧﻥ) Rated current ﺗﻳﺎﺭ ...ﺍﻟﻛﻪ
ﺍﻟﺣﻣﻝ ﺍﻟﻛﺎﻣﻝ( ﻓﻰ ﺍﻟﻣﻠﻑ ﺍﻟﺛﺎﻧﻭﻯ ﻋﻧﺩﻫﺎ ﻧﻘﻳﺱ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺳﻠﻁ ﻋﻠﻰ ﺍﻟﻣﻠﻑ ﻣﺎﻧﻌﺔ ﺍﻟﺻﻭﺍﻋﻕ
Lightning
ﺍﻹﺑﺗﺩﺍﺋﻰ ﻓﻰ ﻫﺫﻩ ﺍﻟﻠﺣﻅﻪ ﻓﻳﻛﻭﻥ ﺍﻟـ Impedance voltage ﻫﻭ ﺍﻟﺟﻬﺩ Arresrtor
ﺃﻧﻭﺍﻉ ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ
ﺍﻟﻣﻘﺎﺱ ﻣﻘﺳﻭﻣﺎ ﻋﻠﻰ ﺍﻟﺟﻬﺩ ﺍﻹﺑﺗﺩﺍﺋﻰ ﺍﻟﻣﻘﻧﻥ ﻭﺍﻷﺑﺭﺍﺝ
ﺃﻧﻭﺍﻉ ﺍﻟﻌﻭﺍﺯﻝ
ﺍﻟﻣﺳﺗﺧﺩﻣﺔ ﻓﻰ
ﻓﻳﻣﺎ ﻳﺳﺗﺧﺩﻡ ﺍﻟـ Impedance voltage ﺃﻭPercentage ﺧﻁﻭﻁ ﺍﻟﻧﻘﻝ
ﺍﻟﻛﻬﺭﺑﻰ
: Impedance ► September
• ﻳﺳﺗﺧﺩﻡ ﻓﻰ ﺗﺣﺩﻳﺩ ﺍﻟـ (Short Circuit Capacity) S.C.C ﻟﻠﻘﺎﻁﻊ )(1
) ( Circuit Breakerﺍﻟﻣﺳﺗﺧﺩﻡ ﻟﺣﻣﺎﻳﺔ ﺍﻟﻣﺣﻭﻝ ﻣﻥ ﺗﻳﺎﺭ ﺍﻟﻘﺻﺭ ﻭﻳﺗﻡ
ﺁﺧﺭ ﺍﻟﺗﻌﻠﻳﻘﺎﺕ
ﺗﺣﺩﻳﺩ (S.C.C) ﻟﻠﻘﺎﻁﻊ ﻛﺎﻷﺗﻰ:
Short Circuit current in secondary = Rated ﺁﺧﺭ ﺍﻟﺗﻌﻠﻳﻘﺎﺕ
…http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8 3/6
6/24/2015 ﺍﻟﻬﻧﺩﺳﻪ ﺍﻟﻛﻬﺭﺑﻳﻪ" ﻋﻠﻡ ﻭﻓﻥ" :ﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔ
secondary current/ %Z ﺗﺣﻣﻳﻝ
ﻣﻐﻳﺭ ﺍﻟﺟﻬﺩ: Tap Changer
ﻫﻭ ﻣﻥ ﺍﻟﻧﻭﻉ off Load Tap Changer ﻭﻳﺳﺗﺧﺩﻡ ﻓﻰ ﻣﺣﻭﻻﺕ
ﺍﻟﺗﻭﺯﻳﻊ ﺍﻟﺗﻰ ﻳﻣﻛﻥ ﻓﺻﻠﻬﺎ ﻋﻥ ﺍﻟﺣﻣﻝ ﻟﺣﻳﻥ ﺗﻌﺩﻳﻝ ﻣﻭﺿﻊ ﻧﻘﻁ ﺍﻟﺗﻭﺻﻳﻝ ﻭﻳﺗﻡ
ﻓﺻﻝ ﺍﻟﺗﻐﺫﻳﻪ ﻋﻠﻰ ﺟﺎﻧﺏ ﺍﻟﺟﻬﺩ ﺍﻟﻣﻧﺧﻔﺽ ﻣﻥ ﺧﻠﻳﺔ ﺍﻟﺧﺭﻭﺝ ﺛﻡ ﻓﺻﻝ ﺳﻛﻳﻧﺔ
ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﻭﺳﻁ ﺍﻟﺩﺍﺧﻝ ﻟﻠﻣﺣﻭﻝ ﻟﻌﺯﻝ ﺍﻟﻣﺣﻭﻝ ﺗﻣﺎﻣﺎ ﻋﻥ ﺃﻯ ﻣﺻﺩﺭ ﻟﻠﺟﻬﺩ
ﻟﺣﻳﻥ ﺍﻹﻧﺗﻬﺎء ﻣﻥ ﺗﻐﻳﻳﺭ ﻣﻭﺿﻊ ﻧﻘﺎﻁ ﺍﻟﺗﻭﺻﻳﻝ ﺣﺗﻰ ﻻ ﺗﺣﺩﺙ ﺷﺭﺍﺭﻩ ﺩﺍﺧﻝ
ﺍﻟﻣﺣﻭﻝ ﻷﻧﻪ ﻏﻳﺭ ﻣﺯﻭﺩ ﺑﻭﺳﻳﻠﻪ ﻹﻁﻔﺎء ﺍﻟﺷﺭﺍﺭﻩ ﺍﻟﺗﻰ ﺗﺅﺩﻯ ﺇﻟﻰ ﺇﻧﻔﺟﺎﺭ
ﺍﻟﻣﺣﻭﻝ ﻭﺇﺷﺗﻌﺎﻝ ﺍﻟﺯﻳﺕ
ﻭﻳﻭﺟﺩ ﻣﻐﻳﺭ ﺍﻟﺟﻬﺩ ﻋﻠﻰ ﻣﻠﻔﺎﺕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﻭﺳﻁ ﻓﻰ ﻣﺣﻭﻻﺕ ﺍﻟﺗﻭﺯﻳﻊ ﻭﻳﻘﻭﻡ
ﺑﺗﻐﻳﻳﺭ ﻋﺩﺩ ﻣﻠﻔﺎﺕ ﺍﻟﺟﻬﺩ ﺍﺍﻟﻣﺗﻭﺳﻁ ﻭﺑﺎﻟﺗﺎﻟﻰ ﺗﻐﻳﻳﺭ ﻧﺳﺑﺔ ﺍﻟﺗﺣﻭﻳﻝ ﻟﻠﻣﺣﻭﻝ
turns ratioﻭﺫﻟﻙ ﻟﻠﺣﻔﺎﻅ ﻋﻠﻰ ﺛﺑﺎﺕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﻧﺧﻔﺽ ﻋﻧﺩ ﺍﻟﻘﻳﻣﻪ ﺍﻟﻣﻘﻧﻧﻪ
) (380Vﻋﻧﺩ ﺗﻐﻳﺭ ﺟﻬﺩ ﺍﻟﺗﻐﺫﻳﻪ) ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﻭﺳﻁ( ﻓﻰ ﺣﺩﻭﺩ%5±
ﺍﻟﻣﺳﻣﻭﺡ ﺑﻬﺎ ﻭﻳﻣﻛﻥ ﺃﻥ ﻳﻛﻭﻥ ﻋﺩﺩ ﺍﻟﺧﻁﻭﺍﺕ ﺧﻣﺱ ﺃﻭ ﺳﺑﻊ ﺧﻁﻭﺍﺕ ﺣﺳﺏ
ﺍﻟﻁﻠﺏ ﻭﻧﺳﺑﺔ ﺍﻟﺗﻐﻳﻳﺭ ﻟﻛﻝ ﺧﻁﻭﻩ ﺗﻛﻭﻥ %2.5± ﻣﻥ ﻣﻘﻧﻥ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﻭﺳﻁ
)(11KV
ﺃﻗﺻﻰ ﻗﻳﻣﻪ ﻳﻣﻛﻥ ﺭﻓﻊ ﺍﻟﺟﻬﺩ ﺇﻟﻳﻬﺎ ﺑﻭﺍﺳﻁﺔ ﻣﻐﻳﺭ ﺍﻟﺟﻬﺩ ﻫﻰ
) (11KV+5%*11Kvﺃﻯ11550V
ﺃﺩﻧﻰ ﻗﻳﻣﻪ ﻳﻣﻛﻥ ﺧﻔﺽ ﺍﻟﺟﻬﺩ ﺇﻟﻳﻬﺎ ﺑﻭﺍﺳﻁﺔ ﻣﻐﻳﺭ ﺍﻟﺟﻬﺩ ﻫﻰ11KV)
(5%*11Kvﺃﻯ10450V
ﻓﻠﻭ ﺇﻧﺧﻔﺽ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﻭﺳﻁ ﻣﻥ 11KV ﺇﻟﻰ 10.5KV ﺍﻯ ﺇﻧﺧﻔﺽ ﺑﻧﺳﺑﺔ
%4.5ﻓﺈﻥ ﺍﻟﺟﻬﺩ ﺍﻟﻣﻧﺧﻔﺽ ﺳﻳﻧﺧﻔﺽ ﺑﻧﻔﺱ ﺍﻟﻧﺳﺑﻪ ﻣﻥ 380V ﺇﻟﻰ
363Vﻭﺫﻟﻙ ﻛﺎﻟﺗﺎﻟﻰ
Vs/10500 = 11000/380
Vs = 380 *(10500/11000) = 363V
ﻭﻟﻛﻰ ﻧﺭﻓﻊ ﻫﺫﻩ ﺍﻟﻘﻳﻣﻪ ( 363V) ﺇﻟﻰ ﺍﻟﻘﻳﻣﻪ ﺍﻟﻣﻘﻧﻧﻪ ( 380V) ﻓﺈﻧﻧﺎ ﻧﺣﺗﺎﺝ
ﻟﻧﺭﻓﻊ ﻧﺳﺑﺔ ﺍﻟﺗﺣﻭﻳﻝ ﻟﺗﺻﺑﺢ%104.5 ﺑﺩﻻ ﻣﻥ %100 ﻭﻫﺫﺍ ﻳﻌﻧﻰ ﺃﻥ ﺟﻬﺩ
ﺍﻟﺧﺭﺝ ﺳﻳﺭﺗﻔﻊ ﺑﻧﻔﺱ ﺍﻟﻧﺳﺑﻪ ﻟﻳﺻﺑﺢ ﻣﺳﺎﻭﻳﺎ
380Vﻛﻣﺎ ﻓﻰ ﺍﻟﻣﻌﺎﺩﻟﻪ:
Vs = 363 * (104.5/100) = 380 V
***********************************************
ﺍﻟﻣﻘﺎﻝ ﻛﺗﺏ ﺑﻭﺍﺳﻁﺔ:
ﻡ/ﻋﻼء ﻣﺣﻣﺩ
ﺃﺩﻣﻥ: ﺍﻟﻬﻧﺩﺳﻪ ﺍﻟﻛﻬﺭﺑﻳﻪ" ﻋﻠﻡ ﻭﻓﻥ"
Posted by eng alaa 2 comments:
ﺍﻟﺭﺋﻳﺳﻳﺔ ,ﻣﺣﻭﻻﺕ ﻛﻬﺭﺑﻳﺔLabels:
…http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8 5/6
6/24/2015 ﻛﻬﺭﺑﻳﺔ ﻣﺣﻭﻻﺕ :"ﻭﻓﻥ "ﻋﻠﻡ ﺍﻟﻛﻬﺭﺑﻳﻪ ﺍﻟﻬﻧﺩﺳﻪ
Home Older Posts
Subscribe to: Posts (Atom)
Picture Window template. Powered by Blogger.
http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8… 6/6