You are on page 1of 6

‫‪6/24/2015‬‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‪ :‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬

‫ﺇﻧﺷﺎء‪ ‬ﻣﺩﻭﻧﺔ‪ ‬ﺇﻟﻛﺗﺭﻭﻧﻳﺔ ‪  ‬ﺗﺳﺟﻳﻝ‪ ‬ﺍﻟﺩﺧﻭﻝ‬ ‫‪  ‬ﺍﻟﻣﺯﻳﺩ‪    ‬ﺍﻟﻣﺩﻭﻧﺔ‪ ‬ﺍﻹﻟﻛﺗﺭﻭﻧﻳﺔ‪ ‬ﺍﻟﺗﺎﻟﻳﺔ«‬ ‫‪1‬‬

‫"ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ‬

‫ﺍﻟﻣﺷﺎﺭﻛﺎﺕ‪ ‬ﺍﻟﺷﺎﺋﻌﺔ‬
‫‪.  Show all posts‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‪Showing posts with label ‬‬
‫‪Star/Delta Starter‬‬

‫ﻟﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‪ Nameplate ‬ﺷﺭﺡ‪ ‬ﺍﻟﺑﻳﺎﻧﺎﺕ‪ ‬ﺍﻟﻭﺭﺍﺩﻩ‪ ‬ﻓﻰ‪ ‬ﺍﻟـ‬

‫‪ Current‬ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻳﺎﺭ‬
‫‪transformers‬‬

‫ﻁﺭﻕ‪ ‬ﺑﺩء‪ ‬ﺗﺷﻐﻳﻝ‪ ‬ﺍﻟﻣﺣﺭﻛﺎﺕ‪ ‬ﺍﻟﺣﺛﻳﻪ‬
‫‪Starting methods of Induction‬‬
‫‪motors‬‬

‫ﺃﻧﻭﺍﻉ‪ ‬ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‪ ‬ﻭﺍﻷﺑﺭﺍﺝ‬

‫ﺍﻳﻬﻣﺎ‪ ‬ﺍﻓﺿﻝ‪ ‬ﻧﻅﺎﻡ‪ 220 ‬ﻓﻭﻟﺕ‪ ‬ﻭﺗﺭﺩﺩ‪50 ‬‬
‫ﻫﺭﺗﺯ‪ ‬ﺃﻡ‪ ‬ﻧﻅﺎﻡ‪ 110 ‬ﻓﻭﻟﺕ‪ ‬ﻭ‪ ‬ﺗﺭﺩﺩ‪60 ‬‬
‫ﻫﺭﺗﺯ‪ ‬؟‬

‫‪ABOUT‬‬

‫‪TOTAL REVIEWS‬‬
‫‪ ‬‬
‫‪7 5 8 6 9‬‬

‫ﺃﻗﺳﺎﻡ‪ ‬ﺍﻟﻣﺩﻭﻧﺔ‬
‫ﺁﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬
‫ﺷﺭﺡ‪ ‬ﺍﻟﺑﻳﺎﻧﺎﺕ‪ ‬ﺍﻟﻭﺭﺍﺩﻩ‪ ‬ﻓﻰ‪ ‬ﺍﻟـ‪ Nameplate ‬ﻟﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‬ ‫ﺍﻟﺭﺋﻳﺳﻳﺔ‬

‫ﻳﺟﺏ‪ ‬ﺃﻥ‪ ‬ﻳﺣﺗﻭﻯ‪ ‬ﻛﻝ‪ ‬ﻣﺣﻭﻝ‪ ‬ﻋﻠﻰ‪ ‬ﻟﻭﺣﺔ‪ ‬ﺑﻳﺎﻧﺎﺕ‪ ‬ﺑﺣﻳﺙ‪ ‬ﻳﺳﻬﻝ‪ ‬ﺍﻟﺗﻌﺎﻣﻝ‪ ‬ﻣﻊ‬ ‫ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‪ ‬ﺍﻟﻛﻬﺭﺑﻰ‬
‫ﺷﺑﻛﺎﺕ‪ ‬ﻛﻬﺭﺑﻳﻪ‬
‫ﺍﻟﻣﺣﻭﻝ‪.‬‬ ‫ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬
‫ﻭﺍﻟﺑﻳﺎﻧﺎﺕ‪ ‬ﺍﻟﻣﻭﺟﻭﺩﺓ‪ ‬ﻋﻠﻰ‪ ‬ﻟﻭﺣﺔ‪ ‬ﺍﻟﺑﻳﺎﻧﺎﺕ‪ ‬ﻛﺎﻟﺗﺎﻟﻰ‪: ‬‬
‫ﻣﺩﻭﻧﺎﺕ‪ ‬ﺻﺩﻳﻘﺔ‬
‫ﺍﺳﻡ‪ ‬ﺍﻟﺷﺭﻛﺔ‪ ‬ﺍﻟﻣﻧﺗﺟﺔ‪. ‬‬
‫ﺳﻧﺔ‪ ‬ﺍﻟﺻﻧﻊ‪ Manfact. Date............................ ‬‬ ‫‪ADS 468X60PX‬‬

‫ﺍﻟﺗﺭﺩﺩ‪Frequency.....................................‬‬
‫‪ABOUT ME‬‬
‫ﺍﻟﻘﺩﺭﺓ‪Power Rated ....................................‬‬ ‫‪eng alaa ‬‬

‫ﻣﺟﻣﻭﻋﺔ‪ ‬ﺍﻟﺗﻭﺻﻳﻝ‪ ‬ﺍﻻﺗﺟﺎﻫﻳﺔ‪Group connection Vector.......‬‬ ‫‪Follow‬‬ ‫‪91‬‬

‫‪View my complete profile‬‬
‫ﺟﻬﺩ‪ ‬ﺍﻟﻣﻌﺎﻭﻗﺔ‪Impedance voltage ......................... ‬‬
‫ﺯﻣﻥ‪ ‬ﺍﻟﻘﺻﺭ‪. Short circuit time ..............................‬‬
‫‪FOLLOWERS‬‬

‫…‪http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8‬‬ ‫‪1/6‬‬
‫‪6/24/2015‬‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‪ :‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬

‫‪Join this site‬‬
‫ﺍﻟﻭﺯﻥ‪ ‬ﺍﻟﻛﻠﻰ‪Total weight ............................‬‬ ‫‪with Google Friend Connect‬‬

‫»‪Members (35)  More ‬‬
‫ﻭﺯﻥ‪ ‬ﺍﻟﺯﻳﺕ‪Oil weight ...............................‬‬
‫ﻁﺭﻳﻘﺔ‪ ‬ﺍﻟﺗﺑﺭﻳﺩ‪Type of cooling .........................‬‬
‫ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ‪Rated current ..........................‬‬
‫ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻘﻧﻥ‪) ‬ﻋﻧﺩ‪ ‬ﻛﻝ‪ ‬ﻧﻘﻁﺔ‪ ‬ﻣﻥ‪ ‬ﻧﻘﺎﻁ‪ ‬ﻣﻐﻳﺭ‪ ‬ﺍﻟﺟﻬﺩ‪Rated voltag ( ‬‬
‫ﻫﺫﻩ‪ ‬ﺻﻭﺭﻩ‪ ‬ﻟﻠﻭﺣﺔ‪ ‬ﺑﻳﺎﻧﺎﺕ‪ ‬ﻣﺣﻭﻝ‪ ‬ﺗﻭﺯﻳﻊ‬
‫‪Already a member? Sign in‬‬

‫ﺃﺭﺷﻳﻑ‪ ‬ﺍﻟﻣﺩﻭﻧﺔ‬
‫)‪▼  2013 (12‬‬
‫)‪▼  October (11‬‬
‫‪ Starting‬ﻁﺭﻕ‪ ‬ﺑﺩء‪ ‬ﺗﺷﻐﻳﻝ‪ ‬ﺍﻟﻣﺣﺭﻛﺎﺕ‪ ‬ﺍﻟﺣﺛﻳﻪ‬
‫‪methods of...‬‬
‫‪Star/Delta Starter‬‬
‫‪ Soft Starters‬ﺃﺟﻬﺯﺓ‪ ‬ﺍﻟﺑﺩء‪ ‬ﺍﻟﻧﺎﻋﻡ‬
‫‪ Current transformers‬ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻳﺎﺭ‬
‫ﺍﻳﻬﻣﺎ‪ ‬ﺍﻓﺿﻝ‪ ‬ﻧﻅﺎﻡ‪ 220 ‬ﻓﻭﻟﺕ‪ ‬ﻭﺗﺭﺩﺩ‪ 50 ‬ﻫﺭﺗﺯ‪ ‬ﺃﻡ‪ ‬ﻧﻅﺎﻡ‬
‫‪110...‬‬
‫ﻟﻣﺣﻭﻻﺕ‪ Nameplate ‬ﺷﺭﺡ‪ ‬ﺍﻟﺑﻳﺎﻧﺎﺕ‪ ‬ﺍﻟﻭﺭﺍﺩﻩ‪ ‬ﻓﻰ‪ ‬ﺍﻟـ‬
‫‪...‬ﺍﻟﺗﻭ‬
‫)‪ (Induction motor ‬ﻣﺎﺫﺍ‪ ‬ﻳﺣﺩﺙ‪ ‬ﻟﻠﻣﺣﺭﻙ‪ ‬ﺍﻟﺣﺛﻰ‬
‫‪...‬ﺇﺫﺍ‪ ‬ﺍﻧﺧﻑ‬
‫ﺍﻟﻣﻣﻳﺯﺍﺕ‪ ‬ﻭﺍﻟﻌﻳﻭﺏ‪ ‬ﻟﻼﻧﻭﺍﻉ‪ ‬ﺍﻟﻣﺧﺗﻠﻔﺔ‪ ‬ﻣﻥ‪ ‬ﺍﻟﻣﺣﺭﻛﺎﺕ‬
‫‪...‬ﺍﻟﻛﻪ‬
‫ﻭﺍﻟﺷﻛﻝ‪ ‬ﺍﻟﺗﺎﻟﻰ‪ ‬ﻫﻭﺷﻛﻝ‪ ‬ﺗﺧﻁﻳﻁﻰ‪ ‬ﻳﻭﺿﺢ‪ ‬ﻟﻭﺣﺔ‪ ‬ﺑﻳﺎﻧﺎﺕ‪ ‬ﻣﺣﻭﻝ‪ ‬ﺗﻭﺯﻳﻊ‬
‫‪ Lightning Arresrtor‬ﻣﺎﻧﻌﺔ‪ ‬ﺍﻟﺻﻭﺍﻋﻕ‬
‫ﺃﻧﻭﺍﻉ‪ ‬ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‪ ‬ﻭﺍﻷﺑﺭﺍﺝ‬
‫ﺃﻧﻭﺍﻉ‪ ‬ﺍﻟﻌﻭﺍﺯﻝ‪ ‬ﺍﻟﻣﺳﺗﺧﺩﻣﺔ‪ ‬ﻓﻰ‪ ‬ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‪ ‬ﺍﻟﻛﻬﺭﺑﻰ‬

‫)‪►  September (1‬‬

‫‪FEATURED POSTS‬‬

‫‪BANNER AD‬‬

‫‪468X60 BANNER AD‬‬

‫‪SOCIAL ICONS‬‬

‫‪PAGES‬‬
‫ﺍﻟﺻﻔﺣﺔ‪ ‬ﺍﻟﺭﺋﻳﺳﻳﺔ‬
‫==============================‬ ‫ﻓﻬﺭﺱ‪ ‬ﺍﻟﻣﺩﻭﻧﺔ‬
‫‪ ­1‬ﺍﻟﻘﺩﺭﺓ‪: Power Rated ‬‬ ‫ﻋﻥ‪ ‬ﺍﻟﻣﺩﻭﻧﺔ‬

‫‪S = 1.732 *VL *IL KV.A‬‬
‫ﺍﺿﺎﻓﺎﺕ‪ ‬ﺑﻠﻭﺟﺭ‬
‫ﺑﺎﻟﻧﺳﺑﺔ‪ ‬ﻟﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‪ ‬ﺗﺗﺭﺍﻭﺡ‪ ‬ﺍﻟﻘﺩﺭﺓ‪ ‬ﺑﻳﻥ‪( 2500kva to 25) ‬‬
‫ﻭﻳﺗﻡ‪ ‬ﺗﺻﻣﻳﻡ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﻋﻠﻰ‪ ‬ﺃﺳﺎﺱ‪ ‬ﺍﻟﻘﺩﺭﺓ‪ ‬ﺍﻟﻅﺎﻫﺭﻳﺔ‪( S ) ‬‬ ‫ﻗﻭﺍﻟﺏ‪ ‬ﺑﻠﻭﺟﺭ‬

‫===============================‬ ‫ﺃﺩﺳﻧﺱ‬

‫‪ ­2‬ﺯﻣﻥ‪ ‬ﺍﻟﻘﺻﺭ‪( Short circuit time ) ‬‬
‫ﻣﺠﺎﻻﺕ ﺍﻟﻬﻨﺪﺳﻪ ﺍﻟﻜﻬﺮﺑﻴﻪ‬ ‫ﻫﻨﺎ ﻧﻨﺎﻗﺶ ﻣﻮﺿﻮﻋﺎﺕ ﻣﺘﻨﻮﻋﻪ ﺗﺘﻌﻠﻖ ﺑﻤﺨﺘﻠﻒ‬
‫ﻭﻫﻭ‪ ‬ﺃﻗﺻﻰ‪ ‬ﻓﺗﺭﺓ‪ ‬ﺯﻣﻧﻳﺔ‪ ‬ﻳﻣﻛﻥ‪ ‬ﺃﻥ‪ ‬ﻳﺗﺣﻣﻠﻬﺎ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﻓﻰ‪ ‬ﺣﺎﻟﺔ‪ ‬ﻭﺟﻭﺩ‪ ‬ﻗﺻﺭ‬

‫…‪http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8‬‬ ‫‪2/6‬‬
‫‪6/24/2015‬‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‪ :‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬
‫‪SUBSCRIBE TO‬‬

‫)ﺛﻼﺛﺔ‪ ‬ﺃﻭﺟﻪ‪ ‬ﻣﻊ‪ ‬ﺍﻷﺭﺿﻰ(‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﺣﻭﻝ‪.‬‬ ‫‪ Posts‬‬

‫ﻭﻫﺫﺍ‪ ‬ﺍﻟﺟﺩﻭﻝ‪ ‬ﻳﺑﻳﻥ‪ ‬ﺯﻣﻥ‪ ‬ﺍﻟﻘﺻﺭ‪ ‬ﻟﻣﺣﻭﻻﺕ‪ ‬ﺫﺍﺕ‪ ‬ﻗﺩﺭﺕ‪ ‬ﻣﺧﺗﻠﻔﻪ‬ ‫‪ All Comments‬‬

‫‪Transformer KV.A …. Short Circuit withstand‬‬
‫‪SOCIAL ICONS‬‬
‫‪Duration‬‬
‫‪Up to 630 KV.A …………………. 2 sec‬‬ ‫‪SEARCH BLOG‬‬
‫‪Search‬‬
‫‪Above 630 up to 2000 KV.A .............…….. 3 sec‬‬
‫‪Above 2000 KV.A ………….…….. 4 sec‬‬ ‫‪BLOG ARCHIVE‬‬
‫===============================‬ ‫)‪▼  2013 (12‬‬
‫)‪▼  October (11‬‬
‫‪ ­3‬ﺟﻬﺩ‪ ‬ﺍﻟﻣﻌﺎﻭﻗﺔ‪:( Impedance Voltage) V% ‬‬
‫ﻁﺭﻕ‪ ‬ﺑﺩء‪ ‬ﺗﺷﻐﻳﻝ‬
‫ﻭﻳﺳﻣﻰ‪ ‬ﺃﻳﺿﺎ‪ ‬ﺍﻟـ‪Percentage Impedance ‬‬ ‫ﺍﻟﻣﺣﺭﻛﺎﺕ‬
‫ﺍﻟﺣﺛﻳﻪ‬
‫ﺗﻌﺭﻳﻑ‪ ‬ﺟﻬﺩ‪ ‬ﺍﻟﻣﻌﺎﻭﻗﺔ‪ Impedance voltage ‬ﺃﻭ‪ ‬ﺍﻟـ‪Percentage ‬‬ ‫‪Starting‬‬
‫‪methods‬‬
‫‪Impedance‬‬ ‫‪of...‬‬
‫‪Star/Delta‬‬
‫ﻫﻭ‪ ‬ﻗﻳﻣﺔ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﺫﻯ‪ ‬ﻳﺳﻠﻁ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻷﺑﺗﺩﺍﺋﻰ‪ ‬ﻭ‪ ‬ﻳﻣﺭﺭ‪ ‬ﻗﻳﻣﺔ‪ ‬ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ‬ ‫‪Starter‬‬

‫(ﺗﻳﺎﺭ‪ ‬ﺍﻟﺣﻣﻝ‪ ‬ﺍﻟﻛﺎﻣﻝ(‪ ‬ﻟﻠﻣﺣﻭﻝ‪ ‬ﻓﻰ‪ ‬ﺣﺎﻟﺔ‪ ‬ﻭﺟﻭﺩ‪ ‬ﻗﺻﺭ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‬ ‫ﺃﺟﻬﺯﺓ‪ ‬ﺍﻟﺑﺩء‪ ‬ﺍﻟﻧﺎﻋﻡ‬
‫‪Soft‬‬
‫ﻣﻘﺳﻭﻣﺎ‪ ‬ﻋﻠﻰ‪ ‬ﻗﻳﻣﺔ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻘﻧﻥ‪ ‬ﻟﻠﻣﻠﻑ‪ ‬ﺍﻷﺑﺗﺩﺍﺋﻰ‪ ‬ﻣﺿﺭﻭﺑﺎ‪ ‬ﻓﻰ‪100 ‬‬ ‫‪Starters‬‬
‫ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻳﺎﺭ‬
‫‪Current‬‬
‫‪transforme‬‬
‫‪Z % = (Vpsc / Vr) X 100‬‬ ‫‪rs‬‬

‫‪Z % = Impedance voltage‬‬ ‫ﺍﻳﻬﻣﺎ‪ ‬ﺍﻓﺿﻝ‪ ‬ﻧﻅﺎﻡ‬
‫‪ 220‬ﻓﻭﻟﺕ‬
‫ﻭﺗﺭﺩﺩ‪50 ‬‬
‫ﻫﺭﺗﺯ‪ ‬ﺃﻡ‪ ‬ﻧﻅﺎﻡ‬
‫‪ = Vpsc‬ﺟﻬﺩ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻷﺑﺗﺩﺍﺋﻰ‪ ‬ﻓﻰ‪ ‬ﺣﺎﻟﺔ‪ ‬ﺍﻟﻘﺻﺭ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‬ ‫‪110...‬‬
‫ﺷﺭﺡ‪ ‬ﺍﻟﺑﻳﺎﻧﺎﺕ‬
‫‪ = Vr‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻘﻧﻥ‪ ‬ﻟﻠﻣﻠﻑ‪ ‬ﺍﻷﺑﺗﺩﺍﺋﻰ‬ ‫ﺍﻟﻭﺭﺍﺩﻩ‪ ‬ﻓﻰ‪ ‬ﺍﻟـ‬
‫‪Nameplate‬‬
‫‪...‬ﻟﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭ‬

‫ﻭﻳﺗﻡ‪ ‬ﺗﺣﺩﻳﺩ‪ ‬ﻗﻳﻣﺔ‪ ‬ﺍﻟـ‪ Impedance voltage ‬ﺑﺈﺟﺭﺍء‪ ‬ﺇﺧﺗﺑﺎﺭ‬ ‫ﻣﺎﺫﺍ‪ ‬ﻳﺣﺩﺙ‪ ‬ﻟﻠﻣﺣﺭﻙ‬
‫ﺍﻟﺣﺛﻰ‬
‫‪ Short circuit Test‬ﻟﻠﻣﺣﻭﻝ‪ ‬ﺣﻳﺙ‪ ‬ﻳﺗﻡ‪ ‬ﻋﻣﻝ‪ ‬ﻗﺻﺭ‪short circuit ‬‬ ‫‪(Induction‬‬
‫ﺇﺫﺍ‪motor ) ‬‬
‫ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‪ ‬ﻟﻠﻣﺣﻭﻝ‪ 3) ‬ﻓﺎﺯﺍﺕ‪ ( ‬ﺛﻡ‪ ‬ﻳﺗﻡ‪ ‬ﺗﺳﻠﻳﻁ‪ ‬ﺟﻬﺩ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‬ ‫‪...‬ﺍﻧﺧﻑ‬
‫ﺍﻟﻣﻣﻳﺯﺍﺕ‪ ‬ﻭﺍﻟﻌﻳﻭﺏ‬
‫ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ‬ﻛﻧﺳﺑﻪ‪ ‬ﻣﻥ‪ ‬ﺍﻟـ‪ Rated Voltage ‬ﺣﻳﺙ‪ ‬ﻳﺗﻡ‪ ‬ﺯﻳﺎﺩﺓ‪ ‬ﻫﺫﺍ‪ ‬ﺍﻟﺟﻬﺩ‬ ‫ﻟﻼﻧﻭﺍﻉ‪ ‬ﺍﻟﻣﺧﺗﻠﻔﺔ‬
‫ﻣﻥ‪ ‬ﺍﻟﻣﺣﺭﻛﺎﺕ‬
‫ﺗﺩﺭﻳﺟﻳﺎ‪ ‬ﻣﻥ‪ ‬ﺍﻟﺻﻔﺭ‪ ‬ﺇﻟﻰ‪ ‬ﺃﻥ‪ ‬ﻳﻣﺭ‪ ‬ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ‪) Rated current ‬ﺗﻳﺎﺭ‬ ‫‪...‬ﺍﻟﻛﻪ‬

‫ﺍﻟﺣﻣﻝ‪ ‬ﺍﻟﻛﺎﻣﻝ(‪ ‬ﻓﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‪ ‬ﻋﻧﺩﻫﺎ‪ ‬ﻧﻘﻳﺱ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺳﻠﻁ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‬ ‫ﻣﺎﻧﻌﺔ‪ ‬ﺍﻟﺻﻭﺍﻋﻕ‬
‫‪Lightning‬‬
‫ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ‬ﻓﻰ‪ ‬ﻫﺫﻩ‪ ‬ﺍﻟﻠﺣﻅﻪ‪ ‬ﻓﻳﻛﻭﻥ‪ ‬ﺍﻟـ‪ Impedance voltage ‬ﻫﻭ‪ ‬ﺍﻟﺟﻬﺩ‬ ‫‪Arresrtor‬‬
‫ﺃﻧﻭﺍﻉ‪ ‬ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‬
‫ﺍﻟﻣﻘﺎﺱ‪ ‬ﻣﻘﺳﻭﻣﺎ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ‬ﺍﻟﻣﻘﻧﻥ‬ ‫ﻭﺍﻷﺑﺭﺍﺝ‬
‫ﺃﻧﻭﺍﻉ‪ ‬ﺍﻟﻌﻭﺍﺯﻝ‬
‫ﺍﻟﻣﺳﺗﺧﺩﻣﺔ‪ ‬ﻓﻰ‬
‫ﻓﻳﻣﺎ‪ ‬ﻳﺳﺗﺧﺩﻡ‪ ‬ﺍﻟـ‪ Impedance voltage ‬ﺃﻭ‪Percentage ‬‬ ‫ﺧﻁﻭﻁ‪ ‬ﺍﻟﻧﻘﻝ‬
‫ﺍﻟﻛﻬﺭﺑﻰ‬
‫‪: Impedance‬‬ ‫‪►  September‬‬
‫•‪ ‬ﻳﺳﺗﺧﺩﻡ‪ ‬ﻓﻰ‪ ‬ﺗﺣﺩﻳﺩ‪ ‬ﺍﻟـ‪ (Short Circuit Capacity) S.C.C ‬ﻟﻠﻘﺎﻁﻊ‬ ‫)‪(1‬‬

‫)‪ ( Circuit Breaker‬ﺍﻟﻣﺳﺗﺧﺩﻡ‪ ‬ﻟﺣﻣﺎﻳﺔ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﻣﻥ‪ ‬ﺗﻳﺎﺭ‪ ‬ﺍﻟﻘﺻﺭ‪ ‬ﻭﻳﺗﻡ‬
‫ﺁﺧﺭ‪ ‬ﺍﻟﺗﻌﻠﻳﻘﺎﺕ‬
‫ﺗﺣﺩﻳﺩ‪ (S.C.C) ‬ﻟﻠﻘﺎﻁﻊ‪ ‬ﻛﺎﻷﺗﻰ‪: ‬‬
‫‪Short Circuit current in secondary = Rated‬‬ ‫ﺁﺧﺭ‪ ‬ﺍﻟﺗﻌﻠﻳﻘﺎﺕ‬

‫…‪http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8‬‬ ‫‪3/6‬‬
‫‪6/24/2015‬‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‪ :‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬

‫‪secondary current/ %Z‬‬ ‫ﺗﺣﻣﻳﻝ‬

‫ﻫﻨﺎ ﻧﻨﺎﻗﺶ ﻣﻮﺿﻮﻋﺎﺕ ﻣﺘﻨﻮﻋﻪ ﺗﺘﻌﻠﻖ ﺑﻤﺨﺘﻠﻒ ﻣﺠﺎﻻﺕ ﺍﻟﻬﻨﺪﺳﻪ ﺍﻟﻜﻬﺮﺑﻴﻪ‬


‫ﻟﻧﻔﺭﺽ‪ ‬ﺃﻧﻪ‪ ‬ﻟﺩﻳﻧﺎ‪ ‬ﻣﺣﻭﻝ‪ ‬ﻗﺩﺭﺗﻪ‪ KVA 2500 ‬ﻭﻟﻪ‪ % Z =%5 ‬ﻓﻳﻛﻭﻥ‬
‫‪Rated secondary current Is‬‬
‫‪=2500*1000/1.732*380=3800 A‬‬
‫‪S.C Current in secondary = 3800/0.05= 76000A=76‬‬
‫‪KA‬‬
‫ﻭﻳﺗﻡ‪ ‬ﺗﺣﺩﻳﺩ‪ S.C.C ‬ﻟﻠﻘﺎﻁﻊ‪ C.B ‬ﺑﻧﺎءﺍ‪ ‬ﻋﻠﻰ‪ ‬ﻫﺫﻩ‪ ‬ﺍﻟﻘﻳﻣﻪ‬
‫ﻭﻧﻼ‪ ‬ﺣﻅ‪ ‬ﺃﻧﻪ‪ ‬ﻓﻰ‪ ‬ﺣﺎﻟﺔ‪ ‬ﺣﺩﻭﺙ‪ ‬ﻗﺻﺭ‪ ‬ﻋﻠﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‪ ‬ﻟﻠﻣﺣﻭﻝ‪: ‬‬
‫‪ ­1‬ﻟﻭﺗﻡ‪ ‬ﺗﺳﻠﻳﻁ‪ %5 ‬ﻣﻥ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ‬ﺍﻟﻣﻘﻧﻥ‪ ‬ﺳﻳﻣﺭ‪ ‬ﻓﻰ‪ ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‬
‫ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ)‪ ‬ﺗﻳﺎﺭ‪ ‬ﺍﻟﺣﻣﻝ‪ ‬ﺍﻟﻛﺎﻣﻝ(‪(3800A) ‬‬
‫ﺑﻳﻧﻣﺎ‪ ‬ﻟﻭ‪ ‬ﺗﻡ‪ ‬ﺗﺳﻠﻳﻁ‪ %100 ‬ﻣﻥ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ‬ﺍﻟﻣﻘﻧﻥ‪ ‬ﺳﻳﻣﺭ‪ ‬ﻓﻰ‪ ‬ﺍﻟﻣﻠﻑ‬
‫ﺍﻟﺛﺎﻧﻭﻯ‪ 20 ‬ﺿﻌﻑ‪ ‬ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ‪( 76KA) ‬‬
‫===============================‬
‫­‪ ‬ﻁﺭﻳﻘﺔ‪ ‬ﺍﻟﺗﺑﺭﻳﺩ‪:Type of cooling ‬‬
‫ﺃﻏﻠﺏ‪ ‬ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‪ ‬ﺗﻛﻭﻥ‪ ‬ﻁﺭﻳﻘﺔ‪ ‬ﺗﺑﺭﻳﺩﻫﺎ‪ ‬ﻣﻥ‪ ‬ﻧﻭﻉ‪ONAN ‬‬
‫‪ .....………....... (O) : Oil‬ﻣﺎﺩﺓ‪ ‬ﺍﻟﺗﺑﺭﻳﺩ‪ ‬ﺍﻟﺩﺍﺧﻠﻰ‪ ‬ﻫﻰ‪ ‬ﺍﻟﺯﻳﺕ‪. ‬‬
‫‪ ............ (N ) : Natural‬ﺣﺭﻛﺔ‪ ‬ﺍﻟﺯﻳﺕ‪ ‬ﺩﺍﺧﻝ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﻁﺑﻳﻌﻳﺔ‪. ‬‬
‫‪ ..................... (A): Air‬ﻣﺎﺩﺓ‪ ‬ﺍﻟﺗﺑﺭﻳﺩ‪ ‬ﺍﻟﺧﺎﺭﺟﻰ‪ ‬ﻟﻠﻣﺣﻭﻝ‪ ‬ﺍﻟﻬﻭﺍء‪. ‬‬
‫‪ ..............(N) : Natural‬ﺣﺭﻛﺔ‪ ‬ﻫﻭﺍء‪ ‬ﺗﺑﺭﻳﺩ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﻁﺑﻳﻌﻳﺔ‪. ‬‬
‫===============================‬
‫‪ ­5‬ﺍﻟﺗﻳﺎﺭ‪ ‬ﺍﻟﻣﻘﻧﻥ‪:( Rated Current) Ir ‬‬
‫‪S = 1.732 * VL * IL‬‬
‫‪IL = S / 1.732 * VL‬‬
‫ﻓﻰ‪ ‬ﺟﺎﻧﺏ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪(380V) ‬‬
‫‪IL = S (VA) / 1.732 * 380‬‬
‫‪IL = S (KVA) / 1.732 * 0.38 = 1.52 * S(KVA‬‬
‫ﻓﻰ‪ ‬ﺟﺎﻧﺏ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪(11KV) ‬‬
‫‪IL = S (KVA) / 1.732 * 11 = 0.052 * S(KVA‬‬
‫===============================‬
‫‪ ­6‬ﻣﺟﻣﻭﻋﺔ‪ ‬ﺍﻟﺗﻭﺻﻳﻝ‪ ‬ﺍﻹﺗﺟﺎﻫﻳﺔ‪( Connection Vector Group) :‬‬
‫ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‪ ‬ﻳﻛﻭﻥ‪ ‬ﺗﻭﺻﻳﻠﻬﺎ‪ Dyn11 ‬ﻭﻣﻌﻧﺎﻫﺎ‪: ‬‬
‫‪ ­: D‬ﻣﻠﻔﺎﺕ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪ ) ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻹﺑﺗﺩﺍﺋﻰ‪ ( ‬ﻣﻭﺻﻠﻪ‪ ‬ﻋﻠﻰ‪ ‬ﺷﻛﻝ‪ ‬ﺩﻟﺗﺎ‪. ‬‬
‫‪ ­: y‬ﻣﻠﻔﺎﺕ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪ ) ‬ﺍﻟﻣﻠﻑ‪ ‬ﺍﻟﺛﺎﻧﻭﻯ‪ ( ‬ﻣﻭﺻﻠﻪ‪ ‬ﻋﻠﻰ‪ ‬ﺷﻛﻝ‪ ‬ﺳﺗﺎﺭ‪.‬‬
‫‪ ­: n‬ﻧﻘﻁﺔ‪ ‬ﺍﻟﺗﻌﺎﺩﻝ‪. ‬‬
‫‪ ­: 11‬ﺟﻬﺩ‪ ‬ﺍﻟﺧﻁ‪ ‬ﻓﻲ‪ ‬ﺟﺎﻧﺏ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪ ‬ﻳﺗﺄﺧﺭﻋﻥ‪ ‬ﺟﻬﺩ‪ ‬ﺍﻟﺧﻁ‪ ‬ﻓﻰ‪ ‬ﺟﺎﻧﺏ‬
‫ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪ ‬ﺑﺯﺍﻭﻳﺔ‪ ‬ﻁﻭﺭ‪ (Phases shift) ‬ﻣﻘﺩﺍﺭﻫﺎ‪= 30 × 11 ‬‬
‫‪ °330‬ﻭﻫﻭ‪ ‬ﻣﺎ‪ ‬ﻳﺳﻣﻰ‪ ‬ﺑﺭﻗﻡ‪ ‬ﺍﻟﻣﺟﻣﻭﻋﺔ‪ ‬ﺍﻹﺗﺟﺎﻫﻳﺔ‪. ‬‬
‫==================================‬
‫…‪http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8‬‬ ‫‪4/6‬‬
‫‪6/24/2015‬‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‪ :‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‬

‫ﻣﻐﻳﺭ‪ ‬ﺍﻟﺟﻬﺩ‪: Tap Changer ‬‬
‫ﻫﻭ‪ ‬ﻣﻥ‪ ‬ﺍﻟﻧﻭﻉ‪ off Load Tap Changer ‬ﻭﻳﺳﺗﺧﺩﻡ‪ ‬ﻓﻰ‪ ‬ﻣﺣﻭﻻﺕ‬
‫ﺍﻟﺗﻭﺯﻳﻊ‪ ‬ﺍﻟﺗﻰ‪ ‬ﻳﻣﻛﻥ‪ ‬ﻓﺻﻠﻬﺎ‪ ‬ﻋﻥ‪ ‬ﺍﻟﺣﻣﻝ‪ ‬ﻟﺣﻳﻥ‪ ‬ﺗﻌﺩﻳﻝ‪ ‬ﻣﻭﺿﻊ‪ ‬ﻧﻘﻁ‪ ‬ﺍﻟﺗﻭﺻﻳﻝ‪ ‬ﻭﻳﺗﻡ‬
‫ﻓﺻﻝ‪ ‬ﺍﻟﺗﻐﺫﻳﻪ‪ ‬ﻋﻠﻰ‪ ‬ﺟﺎﻧﺏ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪ ‬ﻣﻥ‪ ‬ﺧﻠﻳﺔ‪ ‬ﺍﻟﺧﺭﻭﺝ‪ ‬ﺛﻡ‪ ‬ﻓﺻﻝ‪ ‬ﺳﻛﻳﻧﺔ‬
‫ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪ ‬ﺍﻟﺩﺍﺧﻝ‪ ‬ﻟﻠﻣﺣﻭﻝ‪ ‬ﻟﻌﺯﻝ‪ ‬ﺍﻟﻣﺣﻭﻝ‪ ‬ﺗﻣﺎﻣﺎ‪ ‬ﻋﻥ‪ ‬ﺃﻯ‪ ‬ﻣﺻﺩﺭ‪ ‬ﻟﻠﺟﻬﺩ‬
‫ﻟﺣﻳﻥ‪ ‬ﺍﻹﻧﺗﻬﺎء‪ ‬ﻣﻥ‪ ‬ﺗﻐﻳﻳﺭ‪ ‬ﻣﻭﺿﻊ‪ ‬ﻧﻘﺎﻁ‪ ‬ﺍﻟﺗﻭﺻﻳﻝ‪ ‬ﺣﺗﻰ‪ ‬ﻻ‪ ‬ﺗﺣﺩﺙ‪ ‬ﺷﺭﺍﺭﻩ‪ ‬ﺩﺍﺧﻝ‬
‫ﺍﻟﻣﺣﻭﻝ‪ ‬ﻷﻧﻪ‪ ‬ﻏﻳﺭ‪ ‬ﻣﺯﻭﺩ‪ ‬ﺑﻭﺳﻳﻠﻪ‪ ‬ﻹﻁﻔﺎء‪ ‬ﺍﻟﺷﺭﺍﺭﻩ‪ ‬ﺍﻟﺗﻰ‪ ‬ﺗﺅﺩﻯ‪ ‬ﺇﻟﻰ‪ ‬ﺇﻧﻔﺟﺎﺭ‬
‫ﺍﻟﻣﺣﻭﻝ‪ ‬ﻭﺇﺷﺗﻌﺎﻝ‪ ‬ﺍﻟﺯﻳﺕ‬
‫ﻭﻳﻭﺟﺩ‪ ‬ﻣﻐﻳﺭ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﻋﻠﻰ‪ ‬ﻣﻠﻔﺎﺕ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪ ‬ﻓﻰ‪ ‬ﻣﺣﻭﻻﺕ‪ ‬ﺍﻟﺗﻭﺯﻳﻊ‪ ‬ﻭﻳﻘﻭﻡ‬
‫ﺑﺗﻐﻳﻳﺭ‪ ‬ﻋﺩﺩ‪ ‬ﻣﻠﻔﺎﺕ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﺍﻟﻣﺗﻭﺳﻁ‪ ‬ﻭﺑﺎﻟﺗﺎﻟﻰ‪ ‬ﺗﻐﻳﻳﺭ‪ ‬ﻧﺳﺑﺔ‪ ‬ﺍﻟﺗﺣﻭﻳﻝ‪ ‬ﻟﻠﻣﺣﻭﻝ‬
‫‪ turns ratio‬ﻭﺫﻟﻙ‪ ‬ﻟﻠﺣﻔﺎﻅ‪ ‬ﻋﻠﻰ‪ ‬ﺛﺑﺎﺕ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪ ‬ﻋﻧﺩ‪ ‬ﺍﻟﻘﻳﻣﻪ‪ ‬ﺍﻟﻣﻘﻧﻧﻪ‬
‫)‪ (380V‬ﻋﻧﺩ‪ ‬ﺗﻐﻳﺭ‪ ‬ﺟﻬﺩ‪ ‬ﺍﻟﺗﻐﺫﻳﻪ‪) ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ(‪ ‬ﻓﻰ‪ ‬ﺣﺩﻭﺩ‪%5± ‬‬
‫ﺍﻟﻣﺳﻣﻭﺡ‪ ‬ﺑﻬﺎ‪ ‬ﻭﻳﻣﻛﻥ‪ ‬ﺃﻥ‪ ‬ﻳﻛﻭﻥ‪ ‬ﻋﺩﺩ‪ ‬ﺍﻟﺧﻁﻭﺍﺕ‪ ‬ﺧﻣﺱ‪ ‬ﺃﻭ‪ ‬ﺳﺑﻊ‪ ‬ﺧﻁﻭﺍﺕ‪ ‬ﺣﺳﺏ‬
‫ﺍﻟﻁﻠﺏ‪ ‬ﻭﻧﺳﺑﺔ‪ ‬ﺍﻟﺗﻐﻳﻳﺭ‪ ‬ﻟﻛﻝ‪ ‬ﺧﻁﻭﻩ‪ ‬ﺗﻛﻭﻥ‪ %2.5± ‬ﻣﻥ‪ ‬ﻣﻘﻧﻥ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‬
‫)‪(11KV‬‬
‫ﺃﻗﺻﻰ‪ ‬ﻗﻳﻣﻪ‪ ‬ﻳﻣﻛﻥ‪ ‬ﺭﻓﻊ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺇﻟﻳﻬﺎ‪ ‬ﺑﻭﺍﺳﻁﺔ‪ ‬ﻣﻐﻳﺭ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﻫﻰ‬
‫)‪ (11KV+5%*11Kv‬ﺃﻯ‪11550V ‬‬
‫ﺃﺩﻧﻰ‪ ‬ﻗﻳﻣﻪ‪ ‬ﻳﻣﻛﻥ‪ ‬ﺧﻔﺽ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺇﻟﻳﻬﺎ‪ ‬ﺑﻭﺍﺳﻁﺔ‪ ‬ﻣﻐﻳﺭ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﻫﻰ‪11KV­) ‬‬
‫‪ (5%*11Kv‬ﺃﻯ‪10450V ‬‬

‫ﻓﻠﻭ‪ ‬ﺇﻧﺧﻔﺽ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﺗﻭﺳﻁ‪ ‬ﻣﻥ‪ 11KV ‬ﺇﻟﻰ‪ 10.5KV ‬ﺍﻯ‪ ‬ﺇﻧﺧﻔﺽ‪ ‬ﺑﻧﺳﺑﺔ‬
‫‪ %4.5‬ﻓﺈﻥ‪ ‬ﺍﻟﺟﻬﺩ‪ ‬ﺍﻟﻣﻧﺧﻔﺽ‪ ‬ﺳﻳﻧﺧﻔﺽ‪ ‬ﺑﻧﻔﺱ‪ ‬ﺍﻟﻧﺳﺑﻪ‪ ‬ﻣﻥ‪ 380V ‬ﺇﻟﻰ‬
‫‪ 363V‬ﻭﺫﻟﻙ‪ ‬ﻛﺎﻟﺗﺎﻟﻰ‬
‫‪Vs/10500 = 11000/380‬‬
‫‪Vs = 380 *(10500/11000) = 363V‬‬
‫ﻭﻟﻛﻰ‪ ‬ﻧﺭﻓﻊ‪ ‬ﻫﺫﻩ‪ ‬ﺍﻟﻘﻳﻣﻪ‪ ( 363V) ‬ﺇﻟﻰ‪ ‬ﺍﻟﻘﻳﻣﻪ‪ ‬ﺍﻟﻣﻘﻧﻧﻪ‪ ( 380V) ‬ﻓﺈﻧﻧﺎ‪ ‬ﻧﺣﺗﺎﺝ‬
‫ﻟﻧﺭﻓﻊ‪ ‬ﻧﺳﺑﺔ‪ ‬ﺍﻟﺗﺣﻭﻳﻝ‪ ‬ﻟﺗﺻﺑﺢ‪%104.5 ‬ﺑﺩﻻ‪ ‬ﻣﻥ‪ %100 ‬ﻭﻫﺫﺍ‪ ‬ﻳﻌﻧﻰ‪ ‬ﺃﻥ‪ ‬ﺟﻬﺩ‬
‫ﺍﻟﺧﺭﺝ‪ ‬ﺳﻳﺭﺗﻔﻊ‪ ‬ﺑﻧﻔﺱ‪ ‬ﺍﻟﻧﺳﺑﻪ‪ ‬ﻟﻳﺻﺑﺢ‪ ‬ﻣﺳﺎﻭﻳﺎ‬
‫‪ 380V‬ﻛﻣﺎ‪ ‬ﻓﻰ‪ ‬ﺍﻟﻣﻌﺎﺩﻟﻪ‪: ‬‬
‫‪Vs = 363 * (104.5/100) = 380 V‬‬
‫‪*********************************************** ‬‬
‫ﺍﻟﻣﻘﺎﻝ‪ ‬ﻛﺗﺏ‪ ‬ﺑﻭﺍﺳﻁﺔ‪:‬‬
‫ﻡ‪/‬ﻋﻼء‪ ‬ﻣﺣﻣﺩ‬
‫ﺃﺩﻣﻥ‪: ‬ﺍﻟﻬﻧﺩﺳﻪ‪ ‬ﺍﻟﻛﻬﺭﺑﻳﻪ‪" ‬ﻋﻠﻡ‪ ‬ﻭﻓﻥ"‬
‫‪Posted by eng alaa ‬‬ ‫‪2 comments: ‬‬

‫‪+3   Recommend this on Google‬‬

‫ﺍﻟﺭﺋﻳﺳﻳﺔ‪ ,‬ﻣﺣﻭﻻﺕ‪ ‬ﻛﻬﺭﺑﻳﺔ‪Labels: ‬‬

‫…‪http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8‬‬ ‫‪5/6‬‬
6/24/2015 ‫ﻛﻬﺭﺑﻳﺔ‬ ‫ﻣﺣﻭﻻﺕ‬ :"‫ﻭﻓﻥ‬ ‫"ﻋﻠﻡ‬ ‫ﺍﻟﻛﻬﺭﺑﻳﻪ‬ ‫ﺍﻟﻬﻧﺩﺳﻪ‬

Home Older Posts

Subscribe to: Posts (Atom)

Picture Window template. Powered by Blogger.

http://elec4eng.blogspot.com/search/label/%D9%85%D8%AD%D9%88%D9%84%D8%A7%D8%AA%20%D9%83%D9%87%D8%B1%D8%A8%D9%8A%D8… 6/6

You might also like