You are on page 1of 65

Switchgear and

Power Systems
Solutions
Contact Information

Brian Kisner / President Wayne Hartmann / VP Marketing
9400 Globe Center Drive, Suite 116 212 Bobolink Place
Morrisville, NC    27560  Jacksonville, FL    32259
Tel: 919‐818‐4009 Tel: 904‐654‐6175
bkisner@nexgearfast.com          whartmann@nexgearfast.com         
www.nexgearfast.com www.nexgearfast.com
(Headquarters Location) (Remote Office)
2
Our Exploration
• Applications & Solutions Overview
• Introduce NexGear
– Background, Facilities and Staffing
• Applications & Solutions Details
• How NexGear Can Be of Service
• Q & A

3
Applications
• Metal Enclosed Switchgear for Facilities 
– New, retrofit, expansion
• On‐Site Power Systems (24/7)
– New, retrofit, expansion
– Prime, standby, utility paralleled
• Unit Substations
• Enclosed MV, LV, MV/LV Substations
– Power Distribution
– Utility/Facility Interface
• Metal Enclosed Switchgear for Utility 
Substations and Powerplants
4
Applications
• Modular Packaged Generation Systems
– Improved reliability and decreased fuel use
• “Zero Emission” Peak Reduction using 
Packaged Battery Storage Systems 
– ex., 1MWH (2 x 500kWH modules)
• Renewable Firming in Distribution Systems 
Substations using Packaged Storage
– ex., 2MWH (4 x 500kWH modules)
• MicroGrid
– Using conventional and renewable sources plus 
load management
5
Solution Basket
• Medium Voltage Metal‐Clad and Metal‐
Enclosed Switchgear
• Low Voltage Switchgear and Switchboards
• Control Panels / Generator Control Upgrade
• Generator Mounted Solutions (GenBox)
• Automatic Transfer Switches
• Generator Paralleling Switchgear
• Micro Grid and Storage
• Packaging for Gensets, Switchgear 
Substations
• Services
6
Range

• 120V to 38kV
• Facility and Utility
• Indoor/Outdoor 
• New, Retrofit and Expansion
– Switchgear, Switchboards, Panelboards, 
Automatic Transfer Switches, Generator 
Paralleling Switchgear and Control Systems
• Meet NEC, NEMA, UL, ANSI, IEEE and 
other related standards

7
LVSG, LVSB, Control

8
MVSG, Control

9
Facility Activity

10
11
Modular Genset Packages Medium Voltage Switchgear
w/Integrated Switchgear

Switchboards,
UPS & Storage

ATS

ATS w/Maintenance Bypass  Low Voltage Intelligent Power Systems


& Integrated Low Voltage Switchgear Switchgear
About NexGear/PowerSecure
• PowerSecure's businesses provide products and 
services in the areas
– LED Efficient Lighting
– Interactive Distributed Generation 
• DG and On‐Site Power
– Electric Utility EPC
– Intelligent Power Systems

• $140M/Yr., NASDAQ: POWR
– Founded 2000

• NexGear is a division of PowerSecure supplying 
Intelligent Power Systems
– MV/LV Switchgear, Power Management, On‐Site Power 
Systems,  Critical Power Systems, C&I Facility Power 
Systems, Microgrids, Storage and Modular Generation
History of NexGear
• NexGear started in  2002 as 
PowerSecure’s DG Business realized it 
needed to capture value by having an 
internal switchgear/control source 
versus external suppliers
• Small switchgear/controls integrator 
was bought and was named NexGear
• Very experienced staff was added 
2002‐2005 to support growth
History of NexGear
• NexGear grew as PowerSecure’s DG 
and Utility Infrastructure businesses 
grew
• In mid‐2009, a decision was made that 
NexGear would increase its percentage 
of non‐PowerSecure originated 
business
NexGear
Team Experience
• On‐Site Power System Specialists
• 0ver 10 Years of Delivering Switchgear, 
Control, Protection, Automation, 
Packages
• 4,000+MWs of Switchgear Engineered 
and Delivered
• Serve Industrial, Heavy Commercial, 
Institutional and Government Markets
17
Facilities
Randleman Globe RTP‐1 Wake Forest

Globe: Main Office and Factory 27k ft2
RTP‐1: Office and Factory 20k ft2  90 Employees
Wake Forest:  Office and Factory 20k ft2
Randleman:  Packaging Facility 40k ft2 30 Employees
18
NexGear Organization
Brian Kisner
President

Rob Harris
Chris Jankowski VP, Engineering and Chris Ellis Tom Mims Reeba Lambert
VP, Sales Chief Smart Grid VP, Engineering VP, Operations Sales Support Programs
Architect

Direct Sales Pete Maloney


Engineering Staff Engineering Staff Engineering Staff Jordan Hinton
Inside Sales and Project
Management

Wayne Hartmann New Designs, Inside Sales


VP, Marketing
Marketing and
Micro Grid,
Factory Staff Factory Staff
Representative Channels Storage
Marketing &
Agency Sales MV Voltage SG Mike Kocoilek
& OEM VP, Field Service
Will Dickenson Low Voltage SG
VP, Operations Concentration Application
Concentration Field Service,
Commissioning

Engineering Staff

Factory Staff

PowerFab
Medium Voltage
Switchgear

• Metal Clad and Metal Enclosed:  5‐38kV
• Transfer and Load Shed Schemes
• Paralleling Controls
• New or Expansion Switchgear
• Retrofit of Existing Switchgear
• Drop‐In Substation and Portable Designs
• Painted Steel Enclosures,  Indoor/Outdoor
• Manufactured per UL, IEEE and other standards per 
project requirements
20
Low Voltage
Switchgear

• 600 Class AC & DC
• Transfer and Load Shed Schemes
• Paralleling Controls
• New or Expansion Switchgear
• Retrofit of Existing Switchgear
• Drop‐In Substation and Portable Designs
• Painted Steel Enclosures,  Indoor/Outdoor
• Manufactured per UL1558 and other standards 
per project requirements 21
Low Voltage
Switchboards

• 600V Class AC & DC
• Transfer and Load Shed Schemes
• Paralleling Controls
• New or Expansion Switchgear
• Retrofit of Existing Switchgear
• Drop‐In Substation and Portable Designs
• Painted Steel Enclosures,  Indoor/Outdoor
• Manufactured per UL891 and other standards per 
project requirements
22
Control Panels

• Enclosures types NEMA 1, 3, 3R, 3S, 4, 
4X, 12
• Steel, aluminum and stainless steel 
exteriors
• Custom paint available
• Freestanding or bracket/wall mounted
• Conduit entrance from top, side and 
bottom as required
• UL508A 23
Generator 
Paralleling and 
Management 
Upgrade System
(GPMUS)
• Upgrade a power circuit breaker based ATS for Utility parallel operation
• No‐Load & Load Test, Standby and Paralleled Operation
• Bumpless return to Utility power after a Utility outage
• Ability to proactively and bumplessly separate from the Utility when 
outages are likely (severe weather, power emergency)
• Enclosures types NEMA 1, 3, 3R, 3S, 4, 4X, and 12
• Convenient mounting and easy disconnect/reconnect

GPMUS can upgrade many legacy systems with power CBs:
Encorp, Eaton SPB/Magnum, Lakeshore 24
GenBox / GenKits

• GenKit
– Breaker(s), Bus, Backplane, Lugs, Controls for 
placement into existing Breaker Termination Box
• GenBox
– GenKit + New or Expansion Breaker Termination Box
25
GenBox / GenKit Value
• Cost effective power distribution for loads
• Minimizes site work and field engineering
• Eliminate the costs associated with separate 
output distribution equipment
• Eliminates the floor/wall space required by 
separate output distribution equipment

26
“Gen Kit & GenBox”
• Applications for New and Retrofit Installations:
– Single (1) Circuit Breaker Configurations
– Twin (2) Circuit Breaker Configurations
– Multiple (3 and 4) Circuit Breaker Configurations (Dependent Upon 
Enclosure Size)
– Optional Additional Circuit Breakers including House Power CBs, 
Fire Pump CBs, Convenience Power CBs, and Load Bank CBs

• Optional Controls
– Utility‐Generator Automatic Transfer Switch Controls
– Utility‐Generator Manual Transfer Switch Controls
– Generator‐Generator Emergency Power Source Selection Controls
– Utility‐Generator Paralleling Controls
– Generator‐Generator Paralleling Controls
– Load Management Controls

27
“Breaker Kit” Value Add
• Determining suitability of CB for service
– Examine application conditions  to 
recommend optimal CB for the installation
• Attach lugs per application 
• Derive Trip Unit settings 
• Enter settings into Trip Unit
• Primary test complete CB with proper 
settings entered into Trip Unit
28
Automatic Transfer Switches
• 600V Class AC 
• UL 1008; UL 891 or UL 1558 versions available
• 600A– 5000A**
– 5000A, UL 891 or 1558 only
Transfer Switch without
Bypass Isolation • 3 or 4 Pole Designs
– Adaptable to various facility grounding/bonding 
schemes
• PS200 ATS Controller
− Supports all common transfer schemes
− Open or Closed Transition
− Customizable logic if required by application
− Engine Start/Stop Control

Transfer Switch with


Bypass Isolation 29
Automatic Transfer Switches

• Fixed or Drawout Breaker Designs
• Service Entrance Rated Configurations 
Transfer Switch without
Bypass Isolation − CBs with protection, including ground fault if 
required
− Saves cost compared to using separate CB for 
service entrance and contactor ATS
• Maintenance Bypass Isolation Available
− MBPI CBs can be used for automatic transfer 
while primary CBs are being maintained

Transfer Switch with


Bypass Isolation 30
ATS with Integrated LVSG
• Seamless Bus Transition to LV Switchgear
– Ability to Integrate Service Entrance Rating, Utility 
Metering, Disconnect Switch, Transfer Switch, Bypass 
Isolation and Load Switchboard into a Single Bused 
Assembly
– Saves space and cost, and increases reliability
On‐Site Generation Experts

32
Generator Paralleling Switchgear & Control Systems
• LV and MV Systems
• No‐Load & Load 
Test, Standby and 
Paralleled 
Operation
• Single and Multiple 
Generators
• Bumpless return to 
Utility power after a 
Utility outage
• Ability to proactively and bumplessly separate from the Utility when 
outages are likely (severe weather, power emergency)
• Ability to use on‐site power system in Utility demand response 
program for rate incentives
• Enclosures types NEMA 1, 3R
• GPSCS can upgrade many legacy on‐site generator paralleling and 
management systems 33
Simple Application Overview

UTILITY
Communications for Remote
Dispatch and Monitoring

Paralleling
Utility Protection, Metering Switchgear
and Switchgear Control M

Load Bus

System Control & HMI


G

Generator Protection, Metering


and Switchgear Control G LOAD
Engine/Generator
Paralleling System:
UTILITY UTILITY Simple Application
CBs M
ATS

G G
LOAD LOAD
Existing Facility Facility Retrofit with
Switchgear/Automation for
Parallel Generator Operation
Paralleling System:
Complex Application
Generator Paralleling Switchgear & Control System

LV Outdoor Application; Single Main, Single Generator 37
Generator Paralleling Switchgear & Control System

MV Indoor Application; Dual Mains and Multiple Generators 38
Generator Paralleling Switchgear & Control System

MV Indoor Application; Generator and Master Control Sections 39
Packaging
• Generators • PDUs
• Switchgear • UPSs
• Control • Integrated & 
• Enclosures Remote Radiators
• Exhaust • Heat Exchangers 
& Recovery
• Emissions
• Ancillary 
• UL Fuel Tanks
Equipment
40
Packaging
Randleman,
NC

41
Rolling Out Packaged Projects
in Randleman, NC
Packaging

Example:  Three generators, integrated UL fuel tanks, 
generator switchgear and tie switchgear 43
Packaging

Example:  2 Modules, each with:
2 Generators, Generator and Tie Switchgear,  44
Integrated UL Fuel Tanks 
Packaging

CAT 2250kW

45
Packaging

Transformers, MV & LV Switchgear, PDU

46
Packaging

3X 2250kW CATs, Transformers, 
Switchgear, (LV & MV), Control Room

47
Packaging

48
2250kW CAT, Transformer, Switchgear, Heat Recovery
Enclosed LV Substation Packaging

UL 142 Fuel Tank

UL 142 Fuel Tank
49 PDU
MicroGrid & Storage
Utility Grid Diesel Generators Solar Carport

Portable Solar

AC Module DC Module

Operator
Interface

Smart Load Panels


Electric Vehicles
MicroGrid & Storage
Solar Carport
Intelligent Switchgear Modules  (2) 150kW
Electric Vehicles/ with Storage Diesel Generators
Charging Stations

AC and DC Modules
Conventional, Renewable and Storage
Scalable and Modular Approach
UTILITY

Utility Entrance, OSPS, Renewable


Load, Renewable Capacity
Integration & Storage

AC DC
AC/DC RENEWABLE / DC
AC
DC
AC DC
AC/DC RENEWABLE / DC
DIESEL LOADS
Inverter &
Charge Controller Inverters
OSPS/DG

52
Storage in Action:  Discharge On-Peak

Load Shifting &
Demand Reduction
Charge Off-Peak

12AM 12PM 12AM

Storage Scalability

53
UTILITY

SCADA Storage
115kV

Applications
UTILITY
DISTRUBTION
13.8kV SUBSTATION

Substation Bus

Storage

AC/DC
Facility Storage
FEEDERS 13.8kV 480V
for Demand Response Use
UTILITY
SCADA
Utility Distribution Substation Storage
for Demand Response Use 13.8kV FACILITY
DISTRUBTION
480V SUBSTATION
BAS/BMS
Facility Bus

Storage

AC/DC

LOADS
Storage 
Applications

Scalability: Build Capacity for 
Storage Demand and Duration

UTILITY
Facility Use for 
UPS for  E‐Gen Start on Source Failure  SCADA
and Demand Response Use 13.8kV

480V

Storage Storage

AC/DC AC/DC
NexGear Service Group
Switchgear Service
Preventive Maintenance
Relay Testing
Infrared Scans
Ground Fault Testing
Retrofits
Engineering and Services
• Site Surveys
– Project Engineers and Sales Engineers can visit your 
facility to survey needs for new and retrofit work.

• Design/Engineering
– Including switchgear, transformers, cabling, panels, 
protection, automation, metering, communications 
and integration.  We also provide Coordination 
Studies, Short Circuit Analysis and Arc Flash Studies.

• Procurement
– Multi‐vendor capable with agreements with major 
suppliers of breakers, transformers, protection, 
automation, metering, communications and 
integration.
57
Engineering and Services
• Fabrication
– Complete fabrication including metal work, bus work, 
all component mounting and wiring, permanent 
housing and mobile enclosures.

• Factory Testing
– All systems are exercised with secondary or primary 
quantities as appropriate to ensure functionality.  
This includes highly integrated protection, 
automation, metering and communication systems.

• Site Construction/Installation
– Our experienced Crews and Project Managers ensure 
smooth installation of your project.

58
Engineering and Services
• Site Testing/Commissioning
– We apply primary and secondary quantities as appropriate to 
ensure all field connections are correct and the installation is 
fully functional.

• Training
– On‐site training for engineering, operations and maintenance 
personnel, as well as training at our facility during construction 
and factory test.

• Maintenance
– We can care for your installation to ensure many years of highly 
reliable electric service.  In many instances we can employ 
remote systems that gather advanced diagnostic information.

• Field Service
– Switchgear Maintenance, Infrared Testing, Relay Testing, 
Switchgear Trouble Shooting  
59
How NexGear
Can Be of Service
• Be a single source of switchgear and systems 
packaging for optimum coordination and 
single point responsibility
• Provide maximum value with integrated 
engineering and long‐standing  sourcing 
capabilities
• Provide excellent service with experienced 
engineers, fabricators and field professionals  
engaged in mission critical on‐site power 
systems on a day‐to‐day basis

60
Why NexGear???
• Spec/Build and Design/Build Specialists
• 1000s of MWs of On‐Site Power System 
Experience (10+ years)
• Vendor Neutral; Able to Propose Optimal 
Solution
• Expertise in Modern Protection, Control, 
Automation and Integration
• Less Overhead = Better Value
• Fast Quoting and Submittal Approvals
• Rapid Delivery for Custom Designs
• One Supplier for Accountability
– MVSG, LVSG, Controls, Generation
120723

You might also like