You are on page 1of 285

TECHNICAL JAN/2011

CATALOGUE
CURTAIN - WALL SYSTEM
GENERAL
INFORMATION
CONCEPT ADVANTAGES CERTIFICATES
curtain wall system E85
Concept

Е 85 is a 50 mm façade system.
There are several variations of the system:

1 classical façade – with cover caps

2 four sided structural glazing


1
3 two sided structural glazing

3
E 85 technical catalogue
01.2011 1.1
curtain wall system E85

E 85 is a multifunctional system which can be com- The high structural stability of the system is
bined with any kind of glazing and shape as well as achieved with lowest weight of the profiles.
with other materials.
0°C -40°C
E 85 has optimum thermal performance even in
E 85 enables the execution of complex constructions regions with severe weather conditions.
as roofs, cupolas, atriums, pyramids, conservatories.
ISOTHERM 10°C
This system is easy for fabrication in the workshop ISOTHERM 10°C
and effortless to be assembled on ISOTHERM
site. 13°C

Tmin 17,75°C Tmin 13,16°C


0°C 0°C -40°C -40°C

ISOTHERM 10°C ISOTHERM 10°C


ISOTHERM 10°C ISOTHERM 10°C
ISOTHERM 13°C ISOTHERM 13°C

Tmax 19,08°C Tmax 17,44°C


20°C 20°C
Tmin 17,75°C Tmin 13,16°C Tmin 17,75°C Tmin 13,16°C

Tmax 19,08°C Tmax 19,08°C Tmax 17,44°C Tmax 17,44°C


20°C 20°C 20°C 20°C

The proper selection of thermal spacer reduces the


chances for condensation formation

Additional thermal spacer


for optimum performance

E 85 has effective and proved airtightness and and specially constructed supplementary profiles for
watertightness, due to large internal drains on sealing the perimeter of the façade.
three levels, without discontinuity at the junction of
mullions or transoms, carefully designed accessories All characteristics of the system are tested in ift
Rosenheim.

E 85 technical catalogue
01.2011 1.2
curtain wall system E85

There is option to insert photovoltaic and


etalbond composite panels within the façade.

Е 85 is also available in anti – burglar version,


which is suitable for window displays of bank
offices and financial institutions.

Sun protection panels can be easily installed in


front of the system.

E 85 technical catalogue
01.2011 1.3
curtain wall system E85
E 85 with inserted openable parts

projected window

parallel opening window

E 85 technical catalogue
01.2011 1.4
curtain wall system E85
Water drainage principles

3rd level
transom

mullion

water
drainage

specially designed
gasket, which
facilitates water
drainage

B 2nd level
transom

The special geometry of E 85 profiles facilitates Gasket seal (A) and foam seal (B) have firming func-
water drainage tion and also make water drainage easier.
Drainage fitting (C) enables water drainage when
The good drainage of this system is achieved by two connecting two mullions.
levels of drainage and by big channels on mullions
and transoms. New flanges (D) and (E) permit thermal expansion of
the profiles.

E 85 technical catalogue
01.2011 1.5
curtain wall system E85
There is an extended range of options for joining mullions and transoms according to the applied loads
Additional joints can be used case of severe loads

2nd level drainage 3rd level drainage

E 85 technical catalogue
01.2011 1.6
curtain wall system E85

TEST CERTIFICATES SYSTEM Е 85


CERTIFICATE
TEST SAMPLE CHARACTERISTIC RESULT STANDARDS NOTIFIED BODY
NUMBER

Air permeability AE EN 12152


EN 12153
Water tightness R7 EN 12154
static; dynamic 200 Pa/600 Pa EN 12155
Е85 ENV 13050
Structural glazing ift Rosenheim 108 31925 R1e
Resistance to wind ±1,6 kN/m2 EN 13116
load design load; ±2,4 kN/m2
safety load EN 12179

Impact resistance I5 / E 5 EN 14019

Air permeability AE EN 12152


EN 12153
EN 12154
Water tightness RЕ 900 EN 12155
E85 static; dynamic 200 Pa/600 Pa ENV 13050
with cover caps
Resistance to wind ift Rosenheim 108 27811е
±1,6 kN/m2 EN 13116
load design load; ±2,4 kN/m2
safety load EN 12179

Impact resistance I4 / E4 EN 14019


Dead load ad from 0,50 kN EN 13830
glass loads to 6,00 kN ENV 1999-1-1
Е85 ift Rosenheim 108 33146e
Curtain wall Resistance 0,50 kN/m2 EN 13830
to horizontal loads 1,00 kN/m2
2,00 kN/m2 ENV 1999-1-1

E85 Thermal Uf = 2,1-2,6 EN ISO 10077-2


2 Sided structural transmittance W/m2.K ift Rosenheim 432 31927 / 1
glazing EN 12412-2

E85 Thermal Uf = 2,7-3,2 EN ISO 10077-2


4 Sided structural transmittance W/m2.K ift Rosenheim 432 31927 / 2
glazing EN 12412-2

E85 Thermal Uf = 1,6 -2,9 EN ISO 10077-2 ift Rosenheim 432 31927 / 3
with pressure plate transmittance W/m2.K EN 12412-2
E85 Thermal Uf = 1,6-2,3 EN ISO 10077-2
with additional thermal transmittance W/m2.K EN 12412-2 ift Rosenheim 432 31927 / 4
insulation spacer
E85 Architectural
with glazing Sound Insulation Rw = 39 dB EN ISO 140-3 Technology А5.402.06
6-16-4+4 mm EN 717-1
Laboratory - Greece
E85 EN ISO 140-3 Architectural
with glazing Sound Insulation Rw = 41 dB EN 717-1 Technology А5.403.06
4-20-6+6 mm Laboratory - Greece
E85 EN ISO 140-1
with cover cap Sound Insulation Rw = 35 dB EN 717-1 ift Rosenheim 161 30989/V1
glazing 6-15-5 mm EN 20140-3
E85 EN ISO 140-1
with cover cap glazing Sound Insulation Rw = 44 dB EN 717-1 ift Rosenheim 161 30989/V2
13VSG-20-9 VSG EN 20140-3

E 85 technical catalogue
01.2011 1.7
curtain wall system E85
CLASSIFICATION OF CHARACTERISTICS FOR CURTAIN WALLING
ACCORDING TO EN 13830
Characteristic/Value/dimension Classification/Value
Resistance to wind load
npd Declared values
(kN/m2)

Self weight npd Declared values


(kN/m2)

Resistance against Impact


Internal IO I1 I2 I3 I4
npd
Drop height (no information) (200) (300) (450) (700)
(mm)

External ЕO Е1 Е2 Е3 Е4
Drop height npd
(no information) (200) (300) (450) (700)
(mm)

Air permeability
Test pressure A1 A2 A3 A4 AE
npd
(Pa) (150) (300) (450) (600) >600

Watertightness
Test pressure R4 R5 R6 R7 RE
npd
(Pa) (150) (300) (450) (600) >600

Airborne sound insulation


Rw (C;Ctr) npd Declared values
(dB)

Thermal transmittance
Ucw npd Declared values
(W/m2.K)

Fire resistance
Integrity (E) npd E15 Е30 E60 E90
i o, o i, o i

Integrity and insulation (EI)


i o, o i, o i npd EI15 EI30 EI60 EI90

Equipotentiality npd Declared values


Ω

Resistance to horizontal loads


(kN at m sill height) npd Declared values

E 85 technical catalogue
01.2011 1.8
BUILDING
PHYSICS
DIMENSIONING FORMULAE EXAMPLES
curtain wall system E85
Definition of curtain walling

Curtain walling usually consists of vertical and horizontal structural members, connected together and anchored
to the supporting structure of the building and infilled, to form a lightweight, space enclosing continuous skin,
which provides, by itself or in conjunction with the building construction, all the normal functions of an external
wall, but does not take on any of the load bearing characteristics of the building structure.

The curtain walling shall be sufficiently rigid to resist the declared wind loads for serviceability, both posi-
tive and negative. It shall transfer the declared wind loads to the building’s structure, safely, via the fixings
intended for that purpose.

The stated definition is in accordance with European standards EN 13830 and EN 13119.

Liabilities

The stated data and methods are provided by ETEM always be considered by the structural/ façade engi-
Building Systems as a guideline for calculating wind neer responsible for the project.
loads, dead loads, thermal transmittance coefficient,
etc. The solutions presented in these pages are indicative
and can not cover all possible project cases. Because
The following information does not substitute of all of that every single project has to be evaluated by the
applicable regulations – Eurocodes, harmonized Euro- structural/façade engineer in charge taking into con-
pean standards, national or regional building codes. sideration the specific features, such as climate condi-
tions, location, orientation, etc.
The specific conditions and technical details of every
particular project have to be taken into considera- ETEM Building Systems is not liable for any calculations
tion. and conclusions on the basis of the stated information.
All calculations and specifications must be estimated,
The right choice of all façade elements- mullions, endorsed and guaranteed by architect, engineer, pro-
transoms, fixing elements, etc as well as any special fessional or legal entity authorized by law for such
requirements regarding stability of the façade must activities.

Material properties
Aluminium alloy EN AW 6063 F22
Ultimate tensile strength Rm = 210 N/mm2
Yield strength Rp0,2 = 160 N/mm2
Modulus of elasticity Eal = 70 000 N/mm2 = 7.109 kg/m2
Coefficient of thermal expansion α = 0,023 mm/m .K (up to 1,2 mm/m for difference up to 500C)

E 85 technical catalogue
01.2011 2.1
curtain wall system E85
Wind actions
The main influence over the façade is wind action, As a guideline, the wind pressure values with respect
which depends mainly on the height of the curtain to the structure height are given in the table below:
wall and location.

h v q wind pressure suction in middle zone suction in edge zone

cp = 0,8 cp = 0,5 cp = 0,7 cp = 2,0


h/b ≤ 0,25 h/b ≥ 0,5 b/8 ≤ 2 m
(m) (m/s) (kg/m2) (kN/m2)
wp* = 1,25 x 0,8 x q ws = 0,5 x q ws = 0,7 x q ws = 2,0 x q
kN/m2 kN/m2 kN/m2 kN/m2

0- 8 28,3 50 0,5 0,5 0,25 0,35 1,0


8 - 20 35,8 80 0,8 0,8 0,4 0,56 1,6
20 - 100 42,0 110 1,1 1,1 0,55 0,77 2,2
> 100 45,6 130 1,3 1,3 0,65 0,91 2,6

where: *Note: when calculating wind pressure wp the load is


increased with 25%.
h – building height, m
b – building width, m For calculating wind actions, when the wind velocity
v - wind velocity, m/s value is given in m/s, the following formula applies:
q – wind load, kg/m2 / kN/m2
2
w p/s – wind pressure / suction, kN/m2 q = v , kg/m2
16
cp – correction factor

E 85 technical catalogue
01.2011 2.2
curtain wall system E85
Allowable deflections
In accordance with EN 13830 and Eurocode 9 the or 15 mm, whichever is the less, when measured between
allowable deflections are as follows: the points of support or anchorage to the building’s
structure.
Under the declared wind loads the maximum frontal The maximum deflection of any main horizontal framing
deflection of the curtain walling’s framing members from vertical loads (dead loads) shall not exceed L/500
- mullions and transoms - shall not exceed L/200, or 3 mm, whichever is the less.

For mullions and transoms loaded by wind pressure: For transoms loaded by dead loads:

f = L , or 0,015 m whichever is the less (EN 13830) f = L , or 0,003m, whichever is the less (EN 13830)
200 500

Fixing brackets
Fixing brackets must fulfill the following criteria: mullions and transoms and weight of infill panels
- Transfer safely all loads from the façade result- - Permit movement of mullions caused by thermal ex-
ing from the wind pressure, weight of pansion

fixed support movable support

y = 0 mm y = ± 12 mm

z = ±12mm x = ± 12 mm x = ±12mm z = 0 mm

E 85 technical catalogue
01.2011 2.3
curtain wall system E85

Mullions must be fixed using at least two fixing


brackets, which are mounted onto the backing wall
and never on a brick wall.

Mullion is fixed permanently at one point only -


fixed support. The other one or two fixing points
B of mullion must allow movement - movable support.

Fixed support ensures steady fixing of mullions to


the backing wall. It does not allow any movement
of the fixed component after final assembly.
Fixed support bears vertical/dead loads as well as
wind loads acting on a certain part of the structure.

h Movable support also ensures fixing of mullions to


concrete slab
the construction but it allows vertical movement of
the mullion caused by temperature changes. Movable
support bears only wind loads acting on the struc-
ture.
A

h movable support - B

h fixed support - A

E 85 technical catalogue
01.2011 2.4
curtain wall system E85
Choosing the the
Choosing appropriate fixing bracket
appropriate fixing bracket
Simply
Simply supported beam with one fixed andone
supported beam with one fixed
movableand one movable support
support

Fixed support Example

Own weight - dead load Initial data: B

Wpresure/suction
V = g. h . b H = 0-8 m ( middle zone)
v h wind load
g = 0,5 kN/m2
Wind load-pressure f1 = 1,25 dead load
h/
For determining the maximum q = 0,5 kN/m2 A fixed support
permissible wind load the
cp = 0,8 (wind pressure) B movable support
following formulae apply: b b
cp= - 0,5 ( wind suction )
Wp = f1 . q . cp . h/2 . b A
h = 3m
Wind load-suction b = 1,2m Fixed support
Ws = q . cp . h/2 . b
Own weight - dead load
where: V = g . h . b = 0,3 . 3 . 1,2 =
V - load, kN = 1,8 kN
g - weight of mullions, transoms
and infill panels, kN/m2 Wind load
Wp - wind pressure, kN Wp = f1 . q . cp . h/2 . b =
Ws - wind suction, kN = 1,25 . 0,5 . 0,8 . ( 0,5 . 3 ) . 1,2 =
f1 - correction factor
B
= 0,9 kN
q - dynamic load, kN/ m2
cp - correction factor (wind pressure) Ws = q . cp . h/2 . b =
h - floor height, m = 0,5 . (-0,5 ) . (0,5 .3 ) . 1,2 =
b - distance between mullions, m
= (-0,45 ) = 0,45 kN
H - buiding height, m
Movable support

Wind load-pressure Wind load


For determining the maximum Wp = f1 . q . cp . h/2 . b = h
permissible wind load the = 1,25 . 0,5 . 0,8 . (0,5 . 3) . 1,2 =
following formulae apply: = 0,9 kN
Wp = f1 . q . cp . h/2 . b Ws = q . cp . h/2 . b =
= 0,5 . (-0,5) . (0,5 . 3) . 1,2 =

A
Wind load-suction = (-0,45 ) = 0,45 kN
Ws = q . cp . h/2 . b

B
Wpresure/suction

h/

v h

Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
b b Fixing bracket for fixed support must bear both calculated values for dead
A load and wind load.
Movable support Fixing bracket for movable support must bear just wind load.

E 85 technical catalogue
01.2011 2.5
Choosing the appropriate fixing bracket
Continuous simply supported beam
curtain wall system E85
Choosing the appropriate fixing bracket
Continuous simply supported beam

Fixed support end supports Example

A Own weight - dead load


V = g.h.b Initial data:
v h H = 8 -20 m ( middle zone)
Wpresure/suction

Wind load-pressure g = 0,5 kN/m2


For determining the maximum f1 = 1,25
A permissible wind load the q = 0,8 kN/m2
h following formulae apply: cp = 0,8 (wind pressure)
h/ Wp = f1 . q . cp . h/2 . b cp= - 0,5 ( wind suction )
b b h = 3,5m
A Wind load-suction b = 1,0m
Ws = q . cp . h/2 . b
Fixed support
Own weight - dead load
where: V = g . h . b = 0,5 . 3,5 . 1,0 = 1,75 kN
V - load, kN
g - weight of mullions, transoms Wind load
and infill panels, kN/m2
Wp = f1 . q . cp . h/2 . b =
Wp - wind pressure, kN
= 1,25 . 0,8 . 0,8 . ( 0,5 . 3 .5) . 1,0 =
A Ws - wind suction, kN
f1 - correction factor = 1,4 kN
q - dynamic load, kN/ m2
cp - correction factor (wind pressure) Ws = q . cp . h/2 . b =
h - floor height, m = 0,8 . (-0,5 ) . (0,5 .3 ,5) . 1,0 =
b - distance between mullions, m = (-0,7 ) = 0,7 kN
H - buiding height, m
h
Movable support Own weight – dead load
V =g . h . b =
Own weight - dead load = 0,5 . 3,5 . 1,0 = 1,75 kN
V =g . h . b
A Wind load
Wind load-pressure Wp = f1 . q . cp . h . b =
For determining the maximum = 1,25 . 0,8 . 0,8 . 3,5 . 1,0= 2,8 kN
permissible wind load the
following formulae apply: Ws = q . cp . h . b =
Wp = f1 . q . cp . h . b = 0,8 . (-0,5) . 3,5 . 1,0 =
h = (-1,4) = 1,4 kN
Wind load-suction
Ws =q . cp . h . b
A
A v h
Wpresure/suction

h/

A h/
wind load h
dead load
Finally we choose the appropriate fixing bracket with bigger bearing A fixed support
b b
capacity than the calculated value. A
Fixing bracket for fixed support must bear both calculated values for dead Movable support
load and wind load.

E 85 technical catalogue
01.2011 2.6
Choosing the appropriate fixing bracket
Continuous beam with one fixed and two movable supports

curtain wall system E85


Choosing the appropriate fixing bracket
Continuous beam with one fixed and two movable supports

B
vh

Wpresure/suction
Fixed support Example

B B
h
Own weight - dead load Initial data:
h/ V = g . 2h . b H = 0-8 m ( middle zone)
b b g = 0,5 kN/m2
A Wind load-pressure f1 = 1,25
h For determining the maximum q = 0,5 kN/m2
Fixed support permissible wind load the cp = 0,8 (wind pressure)
following formulae apply: cp= - 0,5 ( wind suction )
Wp = f1 . q . cp . h/2 . b h = 3,3m
B Wind load-suction b = 0,9m
B Ws = q . cp . h/2 . b
v h
Wpresure/suction

Own weight - dead load


h/ V=g . 2. h . b =
where:
h/ V - load, kN = 0,5 . 2 . 3,3 . 0,9 =
B =2,97 kN
h g - weight of mullions, transoms
h
and infill panels, kN/m2
b b Wp - wind pressure, kN Wind load
A Wp = f1 . q . cp . h/2 . b =
Ws - wind suction, kN
f 1 - correction factor = 1,25 . 0,5 . 0,8 . ( 0,5 . 3 .3) . 0,9 =
A Movable support ( middle )
q - dynamic load, kN/ m2 = 0,74 kN
cp - correction factor (wind pressure)
h - floor height, m Ws = q . cp . h/2 . b =
B h/ b - distance between mullions, m = 0,5 . (-0,5 ) . (0,5 . 3 ,3) . 0,9 =
vh
Wpresure/suction

H - buiding height, m = (- 3,7 ) = 0,37 kN

B
h
wind load
dead load b b
A
A fixed support
Movable support ( end)
B movable support Movable support ( end)
Wind load
Wind load-pressure Wp = f1 . q . cp . h/2 . b =
For determining the maximum = 1,25 . 0,5 . 0,8 .( 0,5 . 3,3 ) . 0,9 =
permissible wind load the = 0,74 kN
following formulae apply:
Wp = f1 . q . cp . h/2 . b
Movable support ( middle ) Wind load Ws = q . cp . h/2 . b =
Wp = f1 . f2 . q . cp . h . b = Wind load-suction = 0,5 . (-0,5) . ( 0,5 . 3,3 ) . 0,9 =
Wind load-pressure = 1,25 . 1,25 . 0,5 . 0,8 . 3,3 . 0,9 = Ws = q . cp . h/2 . b = (-0,37) = 0,37 kN
For determining the maximum = 1,86 kN
permissible wind load the
following formulae apply: Ws = f2 . q . cp . h . b =
Wp = f1 . f2 . q . cp . h . b = 1,25 . 0,5 . (-0,5) . 3,3 . 0,9 =
= (-0,93) = 0,93 kN
Wind load-suction
Ws = f2 . q . cp . h . b Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
where: Fixing bracket for fixed support must bear both calculated values for dead
f2 - correction factor load and wind load.
Fixing bracket for movable support must bear just wind load.

E 85 technical catalogue
01.2011 2.7
Choosing the appropriate fixing bracket
curtain wall
Continious supported system
beam with one fixed support in the middle and two movable in the end E85
Choosing the appropriate fixing bracket
Continuous supported beam with one fixed support in the middle and two movable in the end
Fixed support Example

Own weight - dead load Initial data:


V = g . 2h . b H = 0-8 m ( middle zone)
B Wind load-pressure
g = 0,5 kN/m2
f1 = 1,25
For determining the maximum q = 0,5 kN/m2
permissible wind load the
cp = 0,8 (wind pressure)
following formulae apply:
h
Wp = f1 . f2 . q . cp . h . b cp= - 0,5 ( wind suction )
h = 3,2m
Wind load-suction b = 1,3m
Ws = f2 . q . cp . h . b
Own weight - dead load
where: V = g . 2h . b =
A V - load, kN = 0,5 . 2 . 3,2 . 1,3 = 4,16 kN
g - weight of mullions, transoms
and infill panels, kN/m2 Wind load
h Wp - wind pressure, kN Wp = f1 . f2 . q . cp . h . b =
Ws - wind suction, kN = 1,25 . 1,25 . 0,5 . 0,8 . 3,2 . 1,3 =
f1 - correction factor = 2,6 kN
f2 - correction factor
q - dynamic load, kN/ m2 Ws = f2 . q . cp . h . b =
cp - correction factor (wind pressure)
B h - floor height, m
= 1,25 . 0,5 . (-0,5 ) . 3,2 . 1,3 =
b - distance between mullions, m = (-1,3) = 1,3 kN
H - buiding height, m

Movable support
B
Wind load-pressure Wind load v h
Wpresure/suction

For determining the maximum Wp = f1 . q . cp . h/2 . b = h/


permissible wind load the = 1,25 . 0,5 . 0,8 . (0,5 . 3,2) . 1,3 =
following formulae apply: = 1,04 kN
Wp = f1 . q . cp . h/2 . b A h/
Ws = q . cp . h/2 . b =
h
= 0,5 . (-0,5) . (0,5 . 3,2) . 1,3 =
Wind load-suction = (-0,52) = 0,52 kN
Ws = q . cp . h/2 . b b b
B

B Fixed support
v h
Wpresure/suction

wind load A
h
dead load Finally we choose the appropriate fixing bracket with bigger bearing capacity
h/
A fixed support than the calculated value.
B movable support b b Fixing bracket for fixed support must bear both calculated values for dead
B
load and wind load.
Movable support Fixing bracket for movable support must bear just wind load.

E 85 technical catalogue
01.2011 2.8
curtain wall system E85

DIMENSIONING OF MULLIONS AND TRANSOMS


profile dimensioning

mullion dimensioning transom dimensioning

simply supported beam continuous beam transom subjected transom subjected


to wind load to glazing weight G

entering necessary entering necessary entering necessary entering necessary


data either in: data either in: data either in: data either in:
-formulas -formulas -formulas -formulas
-tables -tables -tables -tables
-ETEM statics -ETEM statics -ETEM statics -ETEM statics

result – required result – required result – required result – required


moment of inertia moment of inertia moment of inertia moment of inertia

choosing the appropriate choosing the appropriate choosing the appropriate choosing the appropriate
mullion with Jx mullion with Jx transom with Jx transom with Jy
exceeding or equal exceeding or equal exceeding or equal exceeding or equal
to the required Jx to the required Jx to the required Jx to the required Jy

choose the profile which


characteristics exceed or are equal
to both calculated values Jx and Jy

E 85 technical catalogue
01.2011 2.9
curtain wall system E85
Selection of mullion
Wind load actions
1. Simply supported beam
Trapezoidal load
The moment of inertia of a mullion, supported at
two points, subjected to wind load is given by the
following equation: h f h
2
Jxa = w . (a/2) . h . 108 . 25 - 40 (a/2)
4
+16 (a/2)2
1920 . Eal . f h2 h2

2 2 a/2 b/2
Jxb = w . (b/2) . h . 108 . 25 - 40 (b/2) +16 (b/2)
4

1920 . Eal . f h 2 h 2 a b

where:
Jx - moment of inertia,cm4 2
w - wind pressure, kg/m2 Jxa = w . (a/2) . h . 108 . 25 - 40 .(a/2)
4
+16 . (a/2)2 =
a, b - distance betweenmullions,m 1920 . Eal . f h2 h2
h - distance between fixing brackets,m
Eal - modulus of elasticity, kg/m2 = 60 . (1,5/2) . 44 . 108 . 25 - 40 . (1,5/2)2 +16 .(1,5/2)2 =
f - deflection,m 1920 . 7. 109 . 0,015 42 42

For mullions and transoms loaded by wind pressure: = 138,0 cm4


l
f=
200 2
(b/2)2
Jxb = w . (b/2) . h . 108 . 25 - 40 .(b/2)
4
+16 . =
or 0,015 m whichever is the less (EN 13830) 1920 . Eal . f h2 h2
Total required moment of inertia:
= 60 . (1,2/2) . 44 . 108 . 25 - 40 . (1,2/2)2 +16 .(1,2/2)2 =
Jx = Ja + Jb 1920 . 7. 109 . 0,015 42 42
Use ETEM catalogue to choose the appropriate mul-
lion with Jx exceeding or equal to the required Jx. = 111,8 cm4

Example:
Total required moment of inertia:
Initial data:
a = 1.5 m Jx = Ja + Jb = 138,0 + 111,8 = 249,8 cm2
b = 1.2 m
h=4m The appropriate mullion is E 85104 with
w = 60 kg/m2
Jx = 252,5 cm4
Eal = 7.109 kg/m2
f = l = 4 = 0,02>0,015m
200 200
f = 0,015 m in the following formulae :

E 85 technical catalogue
01.2011 2.10
curtain wall system E85

2. Continuous beam
Rectangular load
The required moment of inertia of a mullion, sup-
ported at three points, subjected to wind load is f
given by the following equation: h

Jxa = w . (a/2) . h . 10
4 8

185 . Eal . f
a/2 b/2
a b
Jxb = w . (b/2) . h . 10
4 8

185 . Eal . f f

where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2
a, b - distance between mullions,m
h - distance between fixing brackets,m
Jxa = w . (a/2) . h . 10 = Jxb = w . (b/2) . h . 10 =
4 8 4 8
Eal - modulus of elasticity, kg/m2
f - deflection,m 185 . Eal . f 185 . Eal . f

= 96 . (1,5/2) .93,3 . 10 = = 96 . (1/2) . 3,3


4 8 4. 108
For mullions and transoms loaded by wind pressure: =
185 . 7 . 10 .0,015 185 . 7 . 10 .0,015
9
l
f=
200 = 43,9 cm4 = 29,3 cm4
or 0,015 m whichever is the less (EN 13830)
Total required moment of inertia:
Jx = Ja + Jb Total required moment of inertia:
Use ETEM catalogue to choose the appropriate mul- Jx = Ja + Jb = 43,9 + 29,3 = 73,2 cm2
lion with Jx exceeding or equal to the required Jx.
The appropriate mullion is E 85102 with

Example: Jx = 104,1 cm4


Initial data:
a = 1.5 m
b=1m
h = 3,3 m
w = 96 kg/m2
Eal = 7.109 kg/m2
f = l = 3,3 = 0,016>0,015m
200 200
f = 0,015 m in the following formulae :

E 85 technical catalogue
01.2011 2.11
curtain wall system E85
Selection of transom
Wind load actions

l ≤1 Jx = w . (h0/2) . l . 10
8

h0
h0 120 . Eal . f

h0
l
2 2
Jx = w . (h0/2) . l . 108 . 25 - 40 . (h0/2) +16 . (h0l2/2)
4
l >1
h0 1920 . Eal . f l2 l

h0
where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2 l
l - length of transom, m l
Eal - modulus of elasticity, kg/m2
f - deflection,m
h0 - distance between transoms, m
The appropriate transom is E 85300 with Jx = 2,7 cm
For mullions and transoms loaded by wind pressure:
Initial data:
l l=2m
f= h0 = 1.5 m
200
w = 60 kg/m2
or 0,015 m whichever is the less (EN 13830) Eal = 7.109 kg/m2

Use ETEM catalogue to choose the appropriate tran- l = 2 = 1,33 > 1


som with Jx exceeding or equal to the required Jx. h0 1,5

Example: f= l = 2 = 0,01 < 0,015m


Initial data: 200 200
l = 1,2 m
h0 = 3m f = 0, 01 m in the following formula :
w = 60 kg/m2
Eal = 7.109 kg/m2 2 2
Jx = w . (h0/2) . l . 108 . 25 - 40 . (h02/2) +16 . (h02/2) =
4

1920 . Eal . f l l
l = 1,2 = 0,4≤1
h0 3 = 60 . (1.5/2) . 24 . 108 . 25 - 40 . (1,5/2)2+16 . (1.5/2)2 =
1920 . 7 . 109 . 0,01 22 22
f= l = 1,2 = 0,006 >0,015m
= 11,6 cm4
200 200
The appropriate transom is E 85302 with Jx = 19,5 cm
f = 0, 006 m in the following formula :
Important note : This selection of transoms is not final!
Jx = w . (h0/2) . l . 10 = 60 . (3/2) . 1.2 9. 10 = 2,1 cm4
8 8
We choose the appropriate profile which characteristics
120 . Eal . f 120 . 0,006 . 10 . 7 exceed or are equal to both calculated values Jx and Jy.

E 85 technical catalogue
01.2011 2.12
curtain wall system E85
Calculation of the required glass pane thickness
Weight of the glass pane G is calculated as follows:

G=t. ρglass . lg . hg

where: 10 . lg . hg . w 10 . 2 .1,5 . 60
t - minimum theoretical thickness, mm t= = = 5mm
72 72
ρ glass - specific weight of glass = 2,5 kg/m2 x mm
lg - the smallest dimension of the glass pane,m
hg - the largest dimension of the glass pane,m For double glazing treq = 5 . 1,5 = 7,5 mm

For single glass the minimum thickness is given by


According to ETAG 002 the minimum thickness of the
the following equations:
glass panes for curtain walls is 6 mm.
Because of that we choose double glazing 6/14/6.
hg 10 . lg . hg . w
≤3 t=
lg 72
where:
w - wind pressure,kg/m2

hg lg . 10 . w
<3 t=
lg 4,9

For double glazing, the total thickness of both glass


panel is equal to the thickness of a single glass
pane (evaluated using the above equations) multiplied
by 1.5

For triple glazing, the total thickness of both glass


panel is equal to the thickness of a single glass
pane (evaluated using the above equations) multiplied
by 1.7.

Always consult facade engineer or glazing manufac-


turer when calculating required glazing thickness and
maximum allowable dimensions.
Sample
Initial data:
lg = 2 m
hg = 1,5 m
w = 60 kg/m2

hg 1,5
= = 0,75 ≤ 3
lg 2

E 85 technical catalogue
01.2011 2.13
curtain wall system E85
Glass pane weight
The required moment of inertia of a transom due to G
the weight of the glass pane is given by:
G/2 G/2
Jy1 = G . a . 10 . (3 . l2 - 4 . a2)
8

48 . Eal . f1
a a

The distance a of the glazing supports of the glass l


pane is a= 0.150 m

Self weight Sample


Initial data:
The required moment of inertia of a transom sub- t = 12mm
jected to self weight loading is given by: ρglass = 2,5 kg/m2x mm
lg = 2m
hg = 1,5m
Jy2 = 5 . q . l . 10
4 8

384 . Eal . f2 Eal = 7.109 kg/m2


a = 0,150 m
where: G = t . ρglass . lg . hg = 12 . 2,5 . 2 . 1,5 = 90 kg
G - weight of glass pane, kg
l - length of transom, m f= l = 2 = 0,004 > 3 m
q - weight of transom per linear meter, kg/m 500 500

For transoms loaded by dead loads: f = 0,003 m in the following formula:

l
Jy1 = G . a . 10 . (3 . l2 - 4 . a2) =
8
f=
500 48 . Eal . f

or 0,003m, whichever is the less (EN 13830) 90 . 0,150 . 108 . (3 . 22 - 4 . 0,1502) =


=
Total required moment of inertia: 48 . 7 . 109 . 0,003

Jy = Jy1 + Jy2 = 15,9 cm4

Use ETEM catalogue to choose the appropriate tran- We choose the appropriate profile which characteristics
som with Jy exceeding or equal to the required Jy. exceed or are equal to both calculated values
Jx = 19,5 cm4 and Jy = 15,9 cm4
Use ETEM catalogue to choose the appropriate
profile which characteristics exceed or are equal to The appropriate transom is E 85303 with
both calculated values Jx and Jy. Jx = 45,8 cm4 and Jy = 21,5 cm4

E 85 technical catalogue
01.2011 2.14
curtain wall system E85
Thermal transmittance coefficient Ucw of curtain wall

Ucw = ΣAg .Ug + ΣAp.Up + ΣAf.Uf + Σlg.ψg + Σlp.ψp (1)


ΣAg +Af+Ap
U cw – thermal transmittance of the curtain wall,
(W /m2.K) Aw
U g –thermal transmittance of the glass, (W /m2.K)
U p – thermal transmittance of the panel, (W /m2 .K) Af,i Ag,i
U f – thermal transmittance of the aluminium profile,
(W /m2.K)
I g – total length of the glass spacer, (m)
I p – total length of the panel spacer, (m) Ig
Ψg –linear thermal transmittance of the glass
spacer, (W/m.K)
Uf Ψf
Ψp – linear thermal transmittance of the panel Af,a Ag,a Ug
spacer, (W/m.K)
A g – visible glass area, (m2)
A p – visible panel area, (m2)
Af – aluminium frame area, (m2)
U cw – is calculated by formula (1) U= 1 R= d
U g – is given by the glass manufacturer R λ
U f – is given by the manufacturer of the aluminium
profiles
Up – is given by the panel manufacturer 1 4-
R – thermal resistance, (m2 .K / W) -1 4
d – panel thickness, (m) Af Am Af Am
l -thermal conductivity, (W/m. K)

2- 5-
6 2 5
Am
L3
6 Af
1
1 Ag At
2 1
L L2 1
4 2
4 Ap 3- 6-
3 4
4 3 6
L1
5
5 3
Ag 5 At At
6
5 Af

E 85 technical catalogue
01.2011 2.15
curtain wall system E85

THERMAL TRANSMITTANCE COEFFICIENT OF DIFFERENT PROFILE COMBINATIONS


Test specimen Profile Number Beam Pressure Cover Transom Uvalue
ε = 0.9 plate profile depth (mm)
1a: 31927- S1-01a E 85100 E 85700 E 85714 50 2,2
2a: 31927- S1-02a E 85103 E 85700 E 85714 110 2,3
3a: 31927- S1-03a E 85107 E 85700 E 85714 200 2,3
4a: 31927- S1-04a E 85301 E 85700 E 85714 29 1,9
E 85 SG with 5a: 31927- S1-05a E 85303 E 85700 E 85714 69 2,0
press border 6a: 31927- S1-06a E 85307 E 85700 E 85714 159 2,1
7a: 31927- S1-07a E 85100 E 85700 E 85714 50 2,1
8a: 31927- S1-08a E 85107 E 85700 E 85714 200 2,3
9a: 31927- S1-09a E 85301 E 85700 E 85714 29 1,9
10a: 31927- S1-10a E 85307 E 85700 E 85714 159 2,1
1a: 31927- S2-01a E 85100 - - 50 2,5
2a: 31927- S2-02a E 85103 - - 110 2,7
3a: 31927- S2-03a E 85107 - - 200 2,8
4a: 31927- S2-04a E 85301 - - 29 2,3
5a: 31927- S2-05a E 85303 - - 69 2,4
E 85 SG
6a: 31927- S2-06a E 85307 - - 159 2,5
7a: 31927- S2-07a E 85100 - - 50 2,5
8a: 31927- S2-08a E 85107 - - 200 2,7
9a: 31927- S2-09a E 85301 - - 29 2,2
10a: 31927- S2-10a E 85307 - - 159 2,5
1a: 31927- S3-01a E 85100 E 85700 E 85714 56 2,5
2a: 31927- S3-02a E 85103 E 85700 E 85714 116 2,6
3a: 31927- S3-03a E 85107 E 85700 E 85714 206 2,7
4a: 31927- S3-04a E 85301 E 85700 E 85714 35 2,2
5a: 31927- S3-05a E 85303 E 85700 E 85714 75 2,3
6a: 31927- S3-06a E 85307 E 85700 E 85714 165 2,4
7a: 31927- S3-07a E 85360 E 85700 E 85714 15 2,0
E 85 8a: 31927- S3-08a E 85354 E 85700 E 85714 95 2,2
9a: 31927- S3-09a E 85359 E 85700 E 85714 205 2,3
10a: 31927- S3-10a E 85100 E 85700 E 85714 50 1,9
11a: 31927- S3-11a E 85107 E 85700 E 85714 200 2,1
12a: 31927- S3-12a E 85301 E 85700 E 85714 29 1,7
13a: 31927- S3-13a E 85307 E 85700 E 85714 159 1,9
14a: 31927- S3-14a E 85360 E 85700 E 85714 15 1,5
15a: 31927- S3-15a E 85359 E 85700 E 85714 205 1,6
1a: 31927- S4-01a E 85100 E 85700 E 85714 60 1,9
2a: 31927- S4-02a E 85103 E 85700 E 85714 120 2,0
3a: 31927- S4-03a E 85107 E 85700 E 85714 210 2,1
4a: 31927- S4-04a E 85301 E 85700 E 85714 39 1,9
5a: 31927- S4-05a E 85303 E 85700 E 85714 79 1,9
6a: 31927- S4-06a E 85307 E 85700 E 85714 169 2,0
E 85 with 7a: 31927- S4-07a E 85360 E 85700 E 85714 15 1,8
ET.080173.00 8a: 31927- S4-08a E 85354 E 85700 E 85714 95 2,0
9a: 31927- S4-09a E 85359 E 85700 E 85714 205 2,0
10a: 31927- S4-10a E 85100 E 85700 E 85714 50 1,5
11a: 31927- S4-11a E 85107 E 85700 E 85714 200 1,6
12a: 31927- S4-12a E 85301 E 85700 E 85714 29 1,4
13a: 31927- S4-13a E 85307 E 85700 E 85714 159 1,5
14a: 31927- S4-14a E 85360 E 85700 E 85714 15 1,3
15a: 31927- S4-15a E 85359 E 85700 E 85714 205 1,5

E 85 technical catalogue
01.2011 2.16
TABLES

LIST OF PROFILES CHARACTERISTICS


curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

50
X 6,6 m Ix = 27,70 cm4 Iy = 19,39 cm4
2006 g/m Wx = 6,96 cm3 Wy = 7,75 cm3
E 85100 mullion Y

50
448 mm ex = 2,50 cm еy = 3,98 cm
149 mm ix = 1,93 cm iy = 1,62 cm
66

70
X 6,6 m Ix = 58,04 cm4 Iy = 23,79 cm4
2211 g/m Wx = 12,19 cm3 Wy = 9,51 cm3
E 85101 mullion Y
50

488 mm ex = 2,50 cm еy = 4,76 cm


189 mm ix = 2,66 cm iy = 1,70 cm
86

90
X 6,6 m Ix = 104,15 cm4 Iy = 28,19 cm4
2417 g/m Wx = 18,65 cm3 Wy = 11,27 cm3
E 85102 mullion Y
50

528 mm ex = 2,50 cm еy = 5,58 cm


229 mm ix = 3,41 cm iy = 1,78 cm
106

110
X 6,6 m Ix = 169,00 cm4 Iy = 33,43 cm4
Y 2665 g/m Wx = 26,15 cm3 Wy = 13,37 cm3
E 85103 mullion
50

568 mm ex = 2,50 cm еy = 6,46 cm


269 mm ix = 4,14 cm iy = 1,84 cm
126

130
X 6,6 m Ix = 252,55 cm4 Iy = 38,03 cm4
Y 2881 g/m Wx = 34,40 cm3 Wy = 15,21 cm3
E 85104 mullion
50

608 mm ex = 2,50 cm еy = 7,34 cm


309 mm ix = 4,87 cm iy = 1,89 cm
146

160
X 6,6 m Ix = 417,97 cm4 Iy = 44,95 cm4
3205 g/m Wx = 46,90 cm3 Wy = 17,98 cm3
E 85105 mullion Y
50

668 mm ex = 2,50 cm еy = 8,91 cm


369 mm ix = 5,93 cm iy = 1,95 cm
176

E 85 technical catalogue
01.2011 3.1
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

180
X 6,6 m Ix = 752,98 cm4 Iy = 60,74 cm4
4628 g/m Wx = 74,89 cm3 Wy = 24,30 cm3
E 85106 mullion Y
50

708 mm ex = 2,50 cm еy = 10,06 cm


409 mm ix = 6,63 cm iy = 1,88 cm
196

200
X 6,6 m Ix = 1003,76 cm4 Iy = 71,32 cm4
5165 g/m Wx = 91,01 cm3 Wy = 28,53 cm3
E 85107 mullion Y
50

748 mm ex = 2,50 cm еy = 11,03 cm


449 mm ix = 7,24 cm iy = 1,93 cm
216

200
X 6,6 m Ix = 1326,00 cm4 Iy = 80,93 cm4
Y 6423 g/m Wx = 116,21 cm3 Wy = 32,37 cm3
E 85108 mullion
50

748 mm ex = 2,50 cm еy = 11,41 cm


449 mm ix = 7,47 cm iy = 1,85 cm
216

230
X 6,6 m Ix = 2161,67 cm4 Iy = 110,05 cm4
Y 8416 g/m Wx = 162,85 cm3 Wy = 44,02 cm3
E 85109 mullion
50

808 mm ex = 2,50 cm еy = 13,27 cm


509 mm ix = 8,33 cm iy = 1,88 cm
246

6,6 m Ix = 33,69 cm4 Iy = 2,70 cm4


22.5

X
split 1320 g/m Wx = 6,96 cm3 Wy = 1,87 cm3
E 85152 mullion Y
382 mm ex = 1,44 cm еy = 4,84 cm
90 114 mm ix = 2,62 cm iy = 0,74 cm

6,6 m Ix = 60,99cm4 Iy = 3,40 cm4


22.5

X
split 1536 g/m Wx = 10,58 cm3 Wy = 2,40 cm3
E 85153 mullion Y
422 mm ex = 1,41 cm еy = 5,77 cm
110 134 mm ix = 3,27 cm iy = 0,77 cm

E 85 technical catalogue
01.2011 3.2
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

22.5 X
6,6 m Ix = 99,63 cm4 Iy = 4,09 cm4
split 1752 g/m Wx = 14,85 cm3 Wy = 2,94 cm3
E 85154 mullion Y
462 mm ex = 1,39 cm еy = 6,71 cm
130 154 mm ix = 3,92 cm iy = 0,79 cm

6,6 m Ix = 182,37 cm4 Iy = 5,12 cm4


22.5

X
split 2076 g/m Wx = 22,39 cm3 Wy = 3,75 cm3
E 85155 mullion Y
523 mm ex = 1,37 cm еy = 8,15 cm
160 184 mm ix = 4,87 cm iy = 0,82 cm

suppl. X 6,6 m Ix = 14,00 cm4 Iy = 1,56 cm4


profile for 1004 g/m Wx = 3,95 cm3 Wy = 0,90 cm3
E 85150 split Y
32

343 mm ex = 1,72 cm еy = 3,55 cm


mullion 68.8 0 mm ix = 1,94 cm iy = 0,65 cm

suppl. X 6,6 m Ix = 0,10 cm4 Iy = 0,53 cm4


profile for 230 g/m Wx = 0,10 cm3 Wy = 0,33 cm3
E 85151 Y
32

split 91 mm ex = 1,62 cm еy = 1,07 cm


mullion 33 mm ix = 0,35 cm iy = 0,79 cm
13.5

35.3
X 6,6 m Ix = 36,82 cm4 Iy = 18,31 cm4
mullion for 2311 g/m Wx = 8,70 cm3 Wy = 7,29 cm3
E 85120 substructure Y
50

643 mm ex = 2,51 cm еy = 4,23 cm


94 mm ix = 2,08 cm iy = 1,46 cm
81

6,6 m
7.5

cover 130 g/m


E 19641 cap 81 mm
26.4
26 mm

E 85 technical catalogue
01.2011 3.3
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X

6,6 m Ix = 128,93 cm4 Iy = 128,93 cm4


106
Y
3572 g/m Wx = 20,80 cm3 Wy = 20,80 cm3
90

E 85130 mullion 90° 859 mm ex = 6,20 cm еy = 6,20 cm


259 mm ix = 3,12 cm iy = 3,12 cm
90
106

X
90

6,6 m Ix = 176,02 cm4 Iy = 216,12 cm4


Y 3610 g/m Wx = 27,17 cm3 Wy = 30,62 cm3
E 85135 mullion 135°
141.2

650 mm ex = 7,06 cm еy = 6,48 cm


333 mm ix = 3,63 cm iy = 4,02 cm
90
119.7

X
6,6 m Ix = 6,14 cm4 Iy = 5,17 cm4
suppl. 999 g/m Wx = 2,79 cm3 Wy = 2,07 cm3
Y
E 85140 mullion
50

313 mm ex = 2,50 cm еy = 2,20 cm


profile 19 mm ix = 1,29 cm iy = 1,18 cm
40.1

6,6 m Ix = 7,26 cm4 Iy = 3,89 cm4


X
split 986 g/m Wx = 2,54 cm3 Wy = 2,41 cm3
E 85141 rotating Y
312 mm ex = 1,62 cm еy = 2,86 cm
30

mullion 42 mm ix = 1,41 cm iy = 1,03 cm


55.6

inner 6,6 m Ix = 3,50 cm4 Iy = 3,50 cm4


48

810 g/m Wx = 1,38 cm3 Wy = 1,38 cm3


E 85142 suppl.
Y
48.2

mullion 226 mm ex = 2,53 cm еy = 2,53 cm


profile 90° 29 mm ix = 1,08 cm iy = 1,08 cm
48.2

X
outer 6,6 m Ix = 3,38 cm4 Iy = 3,38 cm4
44

972 g/m Wx = 1,89 cm3 Wy = 1,89 cm3


E 85143 suppl.
.3

Y
35.7

mullion 240 mm ex = 1,79 cm еy = 1,79 cm


profile 90° 0 mm ix = 0,97 cm iy = 0,97 cm
35.7

E 85 technical catalogue
01.2011 3.4
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

15
X 6,01 m Ix = 2,78 cm4 Iy = 7,64 cm4
1015 g/m Wx = 1,33 cm3 Wy = 3,06 cm3
E 85300 2nd level Y

50
transom 300 mm ex = 2,50 cm еy = 2,10 cm
79 mm ix = 0,86 cm iy = 1,43 cm
31

29
X 6,01 m Ix = 7,12 cm4 Iy = 11,55 cm4
1293 g/m Wx = 2,76 cm3 Wy = 4,62 cm3
E 85301 2nd level Y
50

transom 330 mm ex = 2,50 cm еy = 2,61 cm


107 mm ix = 1,22 cm iy = 1,55 cm
45

49
X 6,01 m Ix = 19,52 cm4 Iy = 15,08 cm4
1455 g/m Wx = 6,00 cm3 Wy = 6,03 cm3
E 85302 2nd level Y
50

transom 370 mm ex = 2,50 cm еy = 3,26 cm


147 mm ix = 1,90 cm iy = 1,67 cm
65

69
X 6,01 m Ix = 45,83 cm4 Iy = 21,60 cm4
1785 g/m Wx = 10,54 cm3 Wy = 8,64 cm3
E 85303 2nd level Y
50

transom 410 mm ex = 2,50 cm еy = 4,35 cm


187 mm ix = 2,64 cm iy = 1,81 cm
85

89
X 6,01 m Ix = 98,87 cm4 Iy = 26,45 cm4
2276 g/m Wx = 18,06 cm3 Wy = 10,58 cm3
E 85304 2nd level Y
50

transom 450 mm ex = 2,50 cm еy = 5,47 cm


227 mm ix = 3,42 cm iy = 1,77 cm
105

109
X 6,01 m Ix = 160,52 cm4 Iy = 31,06 cm4
2492 g/m Wx = 25,02 cm3 Wy = 12,42 cm3
E 85305 2nd level Y
50

transom 490 mm ex = 2,50 cm еy = 6,42 cm


267 mm ix = 4,17 cm iy = 1,83 cm
125

E 85 technical catalogue
01.2011 3.5
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

129
X 6,01 m Ix = 240,58 cm4 Iy = 35,67 cm4
2708 g/m Wx = 32,66 cm3 Wy = 14,27 cm3
E 85306 2nd level Y
50

transom 530 mm ex = 2,50 cm еy = 7,37 cm


307 mm ix = 4,90 cm iy = 1,89 cm
145

159
X 6,01 m Ix = 398,72 cm4 Iy = 42,59 cm4
3032 g/m Wx = 45,28 cm3 Wy = 17,04 cm3
E 85307 2nd level Y
50

transom 590 mm ex = 2,50 cm еy = 8,81 cm


367 mm ix = 5,96 cm iy = 1,95 cm
175

X 6,01 m Ix = 22,08 cm4 Iy = 20,50 cm4


2nd level 1080 g/m Wx = 5,85 cm3 Wy = 7,07 cm3
E 85600 suppl. Y
58

283 mm ex = 2,90 cm еy = 3,78 cm


transom 195 mm ix = 2,35 cm iy = 2,27 cm
69

X 6,01 m Ix = 43,64 cm4 Iy = 24,98 cm4


2nd level 1229 g/m Wx = 9,25 cm3 Wy = 8,61 cm3
E 85601 suppl. Y
58

323 mm ex = 2,90 cm еy = 4,72 cm


transom 235 mm ix = 3,10 cm iy = 2,34 cm
89

X 6,01 m Ix = 74,28 cm4 Iy = 29,47 cm4


2nd level 1380 g/m Wx = 13,10 cm3 Wy = 10,16 cm3
E 85602 suppl. Y
58

363 mm ex = 2,90 cm еy = 5,67 cm


transom 275 mm ix = 3,81 cm iy = 2,40 cm
109

X 6,01 m Ix = 115,13 cm4 Iy = 33,95 cm4


2nd level 1531 g/m Wx = 17,37 cm3 Wy = 11,71 cm3
Y
E 85603 suppl.
58

403 mm ex = 2,90 cm еy = 6,63 cm


transom 315 mm ix = 4,50 cm iy = 2,45 cm
129

E 85 technical catalogue
01.2011 3.6
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6

X 6,01 m Ix = 0,41 cm4 Iy = 3,78 cm4


605 g/m Wx = 0,35 cm3 Wy = 1,51 cm3
E 85350 3rd level Y

50
transom 204 mm ex = 2,50 cm еy = 1,18 cm
62 mm ix = 0,43 cm iy = 1,30 cm
16

15
X 6,01 m Ix = 1,49 cm4 Iy = 7,42 cm4
948 g/m Wx = 0,94 cm3 Wy = 2,97 cm3
E 85360 3rd level Y
50

transom 221 mm ex = 2,50 cm еy = 1,58 cm


79 mm ix = 0,65 cm iy = 1,45 cm
25

35
X 6,01 m Ix = 8,70 cm4 Iy = 12,03 cm4
1164 g/m Wx = 3,69 cm3 Wy = 4,81 cm3
E 85351 3rd level Y
50

transom 261 mm ex = 2,50 cm еy = 2,36 cm


119 mm ix = 1,42 cm iy = 1,67 cm
45

55
X 6,01 m Ix = 24,25 cm4 Iy = 16,64 cm4
1380 g/m Wx = 7,37 cm3 Wy = 6,65 cm3
E 85352 3rd level Y
50

transom 301 mm ex = 2,50 cm еy = 3,29 cm


159 mm ix = 2,18 cm iy = 1,80 cm
65

75
X 6,01 m Ix = 58,19 cm4 Iy = 21,49 cm4
1874 g/m Wx = 12,82 cm3 Wy = 8,60 cm3
E 85353 3rd level Y
50

transom 341 mm ex = 2,50 cm еy = 4,54 cm


199 mm ix = 2,90 cm iy = 1,76 cm
85

95
X 6,01 m Ix = 102,48 cm4 Iy = 26,10 cm4
2090 g/m Wx = 18,46 cm3 Wy = 10,44 cm3
E 85354 3rd level Y
50

transom 381 mm ex = 2,50 cm еy = 5,55 cm


239 mm ix = 3,64 cm iy = 1,84 cm
105

E 85 technical catalogue
01.2011 3.7
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

115
X 6,01 m Ix = 162,24 cm4 Iy = 30,71 cm4
2306 g/m Wx = 24,72 cm3 Wy = 12,29 cm3
E 85355 3rd level Y
50

transom 421 mm ex = 2,50 cm еy = 6,56 cm


279 mm ix = 4,36 cm iy = 1,90 cm
125

135
X 6,01 m Ix = 239,09 cm4 Iy = 35,32 cm4
2522 g/m Wx = 31,58 cm3 Wy = 14,13 cm3
E 85356 3rd level Y
50

transom 461 mm ex = 2,50 cm еy = 7,57 cm


319 mm ix = 5,06 cm iy = 1,95 cm
145

165
X 6,01 m Ix = 389,88 cm4 Iy = 42,24 cm4
2846 g/m Wx = 42,93 cm3 Wy = 16,90 cm3
E 85357 3rd level Y
50

transom 521 mm ex = 2,50 cm еy = 9,08 cm


379 mm ix = 6,08 cm iy = 2,00 cm
175

185
X 6,01 m Ix = 516,42 cm4 Iy = 46,85 cm4
3062 g/m Wx = 51,19 cm3 Wy = 18,74 cm3
E 85358 3rd level Y
50

transom 561 mm ex = 2,50 cm еy = 10,09 cm


419 mm ix = 6,75 cm iy = 2,03 cm
195

205
X 6,01 m Ix = 665,65 cm4 Iy = 51,46 cm4
3278 g/m Wx = 60,01 cm3 Wy = 20,58 cm3
E 85359 3rd level Y
50

transom 601 mm ex = 2,50 cm еy = 11,09 cm


459 mm ix = 7,41 cm iy = 2,06 cm
215

235
X 6,01 m Ix = 882,24 cm4 Iy = 58,94 cm4
3448 g/m Wx = 71,59 cm3 Wy = 23,58 cm3
E 85369 3rd level Y
50

transom 661 mm ex = 2,50 cm еy = 12,32 cm


519 mm ix = 8,31 cm iy = 2,15 cm
245

E 85 technical catalogue
01.2011 3.8
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
21.2
X 6,01 m Ix = 1,67 cm4 Iy = 8,74 cm4
3rd level 820 g/m Wx = 1,54 cm3 Wy = 3,50 cm3
Y
E 85380 hidden
50
175 mm ex = 2,50 cm еy = 1,09 cm
transom 91 mm ix = 0,74 cm iy = 1,70 cm
21.2

6,01 m Ix = 7,62 cm4 Iy = 4,98 cm4


1131 g/m Wx = 3,14 cm3 Wy = 2,08 cm3
E 85320 2nd level
312 mm ex = 2,40 cm еy = 2,43 cm
42

split transom
60 mm ix = 1,35 cm iy = 1,09 cm
29
45

6,01 m Ix = 19,34 cm4 Iy = 5,21 cm4


1061 g/m Wx = 5,80 cm3 Wy = 2,04 cm3
E 85370 3rd level
341 mm ex = 2,55 cm еy = 3,34 cm
40

split transom
77 mm ix = 2,22 cm iy = 1,15 cm
55
65

6,01 m Ix = 8,56 cm4 Iy = 6,26 cm4


suppl. 791 g/m Wx = 2,74 cm3 Wy = 1,82 cm3
E 85670 profile
68.9

294 mm ex = 3,44 cm еy = 3,12 cm


for E 85370 13 mm ix = 1,71 cm iy = 1,46 cm
51

X 6,01 m Ix = 38,50 cm4 Iy = 8,12 cm4


1329 g/m Wx = 7,97 cm3 Wy = 1,33 cm3
54.5

Y
E 85410 frame 415 mm ex = 3,19 cm еy = 4,83 cm
186 mm ix = 2,77 cm iy = 1,34 cm
90.3

X
6,01 m Ix = 12,87 cm4 Iy = 4,62 cm4
Y 886 g/m Wx = 3,55 cm3 Wy = 1,49 cm3
49

E 85400 frame 339 mm ex = 3,10 cm еy = 3,62 cm


61.4
185 mm ix = 1,98 cm iy = 1,19 cm

E 85 technical catalogue
01.2011 3.9
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

X 6,01 m Ix = 30,66 cm4 Iy = 8,17 cm4


sash for 1413 g/m Wx = 7,63 cm3 Wy = 1,99 cm3
Y
E 85210 projected 49.5
365 mm ex = 2,81 cm еy = 4,35 cm
window 105 mm ix = 2,54 cm iy = 1,31 cm
79

X
6,01 m Ix = 30,90 cm4 Iy = 8,15 cm4
sash for Y 1416 g/m Wx = 7,57 cm3 Wy = 1,92 cm3
E 85211
49.5

parallel 357 mm ex = 2,81 cm еy = 4,44 cm


window 104 mm ix = 2,53 cm iy = 1,30 cm
79

X 6,01 m Ix = 11,78 cm4 Iy = 6,71 cm4


sash for 934 g/m Wx = 3,72 cm3 Wy = 1,92 cm3
E 85200 projected Y
287 mm ex = 3,49 cm еy = 3,17 cm
55.3

window 209 mm ix = 1,84 cm iy = 1,39 cm


57.8

6,01 m
external 208 g/m
E 85614 glass
27.9

99 mm
support 19.2 43 mm

6,01 m
external
14.8

200 g/m
E 85615 glass 101 mm
support 22 46 mm

4,4 m
4.3

operating 159 g/m


E 2308 rod 48 mm
19.7 0 mm

E 85 technical catalogue
01.2011 3.10
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

4,40 m

4.7
operating 197 g/m
E 2309 rod 55 mm
23.5
0 mm

6,01 m
4.8

130 g/m
E 85915 spacer 66 mm
19 0 mm

6,01 m
10.2

pressure 435 g/m


E 85700 plate 151 mm
47.6
0 mm
23.6

6,01 m
pressure 655 g/m
E 85745 plate 205 mm
47.6
0 mm

6,01 m
10.2

pressure 403 g/m


E 85701 plate for 138 mm
slope > 25° 46.4
0 mm

6,01 m
pressure
5.5

416 g/m
E 85702 plate for 113 mm
50
slope > 15° 54 mm

E 85 technical catalogue
01.2011 3.11
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m
pressure 1034 g/m
25.9
E 85703 plate for 305 mm
angle 7.5° 70.7 51 mm

6,01 m
pressure 1121 g/m
E 85704 plate for
28.2

327 mm
angle 15° 63 mm
80.8

6,01 m
pressure 1204 g/m
E 85705 plate for
31.6

349 mm
angle 22.5° 74 mm
89.8

6,01 m
pressure 1291 g/m
E 85706 plate for
35.9

371 mm
angle 30° 86 mm
97

6,01 m
pressure 1455 g/m
E 85707 plate for 413 mm
44

angle 37.5° 106 mm


110.2

6,01 m
pressure 1620 g/m
E 85708 plate for 455 mm
53.8

angle 45° 128 mm


119.2

E 85 technical catalogue
01.2011 3.12
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m

19.1
pressure 510 g/m
E 85740 plate for 170 mm
corner 90° 42.2
0 mm

6,01 m
pressure
18.2

508 g/m
E 85741 plate for 169 mm
corner 135° 46.2 0 mm

6,01 m
12.3

pressure 384 g/m


E 85709 plate 169 mm
50
41 mm

6,01 m
cover cap 126 g/m
6

E 85719 for E 85709 87 mm


24.3
37 mm

6,01 m
10.2

pressure 348 g/m


E 85750 plate 130 mm
48
42 mm

6,01 m
4.9

cover cap 54 g/m


E 85751 for E 85750 45 mm
13.8
16 mm

E 85 technical catalogue
01.2011 3.13
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m
cover 289 g/m
E 85711
50
cap 144 mm
12 75 mm

6,01 m
cover 332 g/m
E 85712 cap
50

166 mm
15 81 mm

6,01 m
cover 400 g/m
E 85713 cap
50

191 mm
20 91 mm

6,01 m
cover 432 g/m
E 85714 cap
50

211 mm
25 101 mm

6,01 m
cover 467 g/m
E 85715 cap
50

231 mm
30 111 mm

6,01 m
cover 821 g/m
E 85716 cap
50

291 mm
60 171 mm

E 85 technical catalogue
01.2011 3.14
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m
cover 1779 g/m
E 85718 cap
50

506 mm
165 381 mm

6,01 m
cover 467 g/m
E 85720 cap
50

206 mm
25
121 mm

6,01 m
cover 281 g/m
E 85721 cap
50

150 mm
18
77 mm

6,01 m
cover 462 g/m
E 85722 cap
50

231 mm
40
110 mm

6,01 m
cover 1207 g/m
E 85723 cap
50

337 mm
100 216 mm

6,01 m
cover 1627 g/m
E 85724 cap
50

453 mm
160
333 mm

E 85 technical catalogue
01.2011 3.15
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m
cover 262 g/m
E 85730 cap
50
132 mm
12
67 mm

6,01 m
17.6

cover cap 373 g/m


E 85731 corner 90° 171 mm
45 61 mm

6,01 m
20.4

cover cap 446 g/m


E 85732 corner 135° 206 mm
49.8 79 mm

6,01 m
cover cap - g/m
E 85790 inox
51

- mm
15
- mm

6,01 m
cover cap - g/m
E 85791 inox
51

- mm
- mm
20

X 6,01 m Ix = 3,93 cm4 Iy = 8,95 cm4


transom Y 724 g/m Wx = 1,39 cm3 Wy = 3,90 cm3
E 85906 connector
45.6

251 mm ex = 2,30 cm еy = 2,83 cm


0 mm ix = 1,21 cm iy = 1,83 cm
40

E 85 technical catalogue
01.2011 3.16
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

X 6,01 m Ix = 9,79 cm4 Iy = 10,20 cm4


transom Y 1010 g/m Wx = 4,20 cm3 Wy = 4,47 cm3
E 85907 connector 45.6 187 mm ex = 2,28 cm еy = 2,33 cm
0 mm ix = 1,62 cm iy = 1,65 cm
45.7

X 6,01 m Ix = 0,04 cm4 Iy = 2,02 cm4


base for Y 367 g/m Wx = 0,08 cm3 Wy = 0,95 cm3
E 85908 transom
42.6

109 mm ex = 2,13 cm еy = 0,44 cm


connector 0 mm ix = 0,16 cm iy = 1,22 cm
6.5

X 2,01 m Ix = 10,31 cm4 Iy = 12,85 cm4


transom Y 1557 g/m Wx = 4,25 cm3 Wy = 5,71 cm3
E 85994 connector
45

261 mm ex = 2,25 cm еy = 2,43 cm


43.2 0 mm ix = 1,34 cm iy = 1,49 cm

X 2,01 m Ix = 9,82 cm4 Iy = 11,31 cm4


insert 1739 g/m Wx = 4,96 cm3 Wy = 5,01 cm3
E 85951 for E 85101 Y
45.2

240 mm ex = 2,26 cm еy = 1,98 cm


0 mm ix = 1,24 cm iy = 1,33 cm
38.2

X 2,01 m Ix = 31,32 cm4 Iy = 13,91 cm4


insert 2041 g/m Wx = 10,71 cm3 Wy = 6,15 cm3
E 85952 for E 85102 Y
45.2

280 mm ex = 2,26 cm еy = 2,92 cm


0 mm ix = 2,04 cm iy = 1,36 cm
58.2

X 2,01 m Ix = 67,86 cm4 Iy = 16,05 cm4


insert 2344 g/m Wx = 17,02 cm3 Wy = 7,30 cm3
E 85953 for E 85103 Y
45.2

320 mm ex = 2,26 cm еy = 3,99 cm


0 mm ix = 2,80 cm iy = 1,38 cm
78.2

E 85 technical catalogue
01.2011 3.17
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

X 2,01 m Ix = 121,71 cm4 Iy = 19,10 cm4


insert 2646 g/m Wx = 24,17 cm3 Wy = 8,45 cm3
E 85954 for E 85104 Y
45.2
360 mm ex = 2,26 cm еy = 5,04 cm
0 mm ix = 3,52 cm iy = 1,40 cm
98.2

X 2,01 m Ix = 239,90 cm4 Iy = 22,99 cm4


insert Y 3100 g/m Wx = 36,40 cm3 Wy = 10,17 cm3
E 85955 for E 85105
45.2

420 mm ex = 2,26 cm еy = 6,59 cm


0 mm ix = 4,57 cm iy = 1,42 cm
128.2

X 2,01 m Ix = 311,58 cm4 Iy = 23,06 cm4


insert 3275 g/m Wx = 42,32 cm3 Wy = 10,43 cm3
E 85956 for E 85106 Y
44.2

449 mm ex = 2,21 cm еy = 7,36 cm


0 mm ix = 5,07 cm iy = 1,38 cm
143.7

X 2,01 m Ix = 425,36 cm4 Iy = 24,21 cm4


insert 3532 g/m Wx = 50,82 cm3 Wy = 11,11 cm3
E 85957 for E 85107 Y
43.6

488 mm ex = 2,18 cm еy = 8,37 cm


0 mm ix = 5,70 cm iy = 1,36 cm
163.7

X 2,01 m Ix = 368,85 cm4 Iy = 23,17 cm4


insert 3499 g/m Wx = 46,79 cm3 Wy = 10,73 cm3
E 85958 for E 85108 Y
43.2

469 mm ex = 2,16 cm еy = 7,88 cm


0 mm ix = 5,34 cm iy = 1,34 cm
154.7

X 2,01 m Ix = 138,19 cm4 Iy = 39,69 cm4


insert for
Y 3977 g/m Wx = 30,46 cm3 Wy = 18,38 cm3
E 85961 polygonal
43.2

255 mm ex = 2,16 cm еy = 4,54 cm


atriums
90 0 mm ix = 3,06 cm iy = 1,64 cm

E 85 technical catalogue
01.2011 3.18
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

roof X 2,01 m Ix = 1076,08 cm4 Iy = 60,25 cm4


connector/ Y 7680 g/m Wx = 117,52 cm3 Wy = 32,79 cm3
E 85969 insert for
40.8

545 mm ex = 2,04 cm еy = 9,17 cm


E 85109 0 mm ix = 5,80 cm iy = 1,45 cm
181.7

X 2,01 m Ix = 1908,80 cm4 Iy = 108,21 cm4


10916 g/m Wx = 175,48 cm3 Wy = 47,88 cm3
E 85960 roof Y
45.2

connector 624 mm ex = 2,26 cm еy = 10,88 cm


0 mm ix = 6,87 cm iy = 1,64 cm
216

2,01 m Ix = 3,26 cm4 Iy = 0,81 cm4


15.5

insert X
Y 764 g/m Wx = 2,04 cm3 Wy = 1,04 cm3
E 85972 for E 85152 93 mm ex = 0,78 cm еy = 1,60 cm
31.9 iy = 0,54 cm
0 mm ix = 1,07 cm

2,01 m Ix = 11,95 cm4 Iy = 1,24 cm4


15.5

insert X
Y 1034 g/m Wx = 4,60 cm3 Wy = 1,59 cm3
E 85973 for E 85153 133 mm ex = 0,78 cm еy = 2,60 cm
51.9
0 mm ix = 1,77 cm iy = 0,57 cm

2,01 m Ix = 28,29 cm4 Iy = 1,67 cm4


15.5

insert X
Y 1304 g/m Wx = 7,87 cm3 Wy = 2,14 cm3
E 85974 for E 85154 173 mm ex = 0,78 cm еy = 3,60 cm
71.9 0 mm ix = 2,42 cm iy = 0,59 cm

2,01 m Ix = 71,55 cm4 Iy = 2,31 cm4


15.5

insert X
Y 1709 g/m Wx = 14,04 cm3 Wy = 2,97 cm3
E 85975 for E 85155 233 mm ex = 0,78 cm еy = 5,10 cm
101.9 0 mm ix = 3,36 cm iy = 0,60 cm

E 85 technical catalogue
01.2011 3.19
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m

8.7
97 g/m

6
E 85640 spacer 6 mm 59 mm
10
6 mm

6,01 m
12.7

10

130 g/m
E 8611 spacer 10 mm 82 mm
10
10 mm

6,01 m
14.7

140 g/m
12

E 85641 spacer 12 mm 90 mm
10
12 mm

6,01 m
20.7

200 g/m
E 85642 spacer 18 mm
18

10
98 mm
18 mm

6,01 m
9.9

101 g/m
6

E 85650 spacer 7,5° 61 mm


10
6 mm

6,01 m
11.3

6.2

108 g/m
E 85651 spacer 15° 65 mm
10
6 mm

E 85 technical catalogue
01.2011 3.20
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m

12.8
117 g/m

6.5
E 85652 spacer 22,5° 69 mm
10
7 mm

6,01 m
14.6

128 g/m
6.9

E 85653 spacer 30° 75 mm


10
7 mm

6,01 m
16.8

7.5

142 g/m
E 85654 spacer 37,5° 82 mm
10
8 mm

6,01 m
19.8

8.5

161 g/m
E 85655 spacer 45° 93 mm
10
9 mm

6,01 m
spacer for
9.3

70 g/m
33 879 structural 53 mm
glazing 0 mm
11

E 85 technical catalogue
01.2011 3.21
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

19.3 6,01 m
spacer for 229 g/m
E 85990 structural
24
138 mm
glazing 0 mm

6,01 m
spacer for 139 g/m
9

33 501 structural 71 mm
glazing 16
0 mm

22 6,01 m
8.9

glazing clip 307 g/m


33 881 for 33 879 68 mm
0 mm

6,01 m
8.6

596 g/m
E 85920 glazing clip 110 mm
43.6 0 mm

6,01 m
602 g/m
10

E 85921 glazing clip 115 mm


43.6
0 mm

6,01 m
17.2

glazing 383 g/m


E 85902 support 122 mm
44.9
0 mm

E 85 technical catalogue
01.2011 3.22
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m

17.2
glazing 408 g/m
E 85916 support 130 mm
48.9 0 mm

6,01 m
17.2

glazing 446 g/m


E 85910 support 142 mm
54.9 0 mm

2,01 m
9.7

glazing 246 g/m


E 85912 support 79 mm
29.8 0 mm

6,01 m
9.7

glazing 266 g/m


E 85917 support 86 mm
33.3
0 mm

2,01 m
glazing 306 g/m
9.7

E 85914 support 99 mm
39.8
0 mm

6,01 m Ix = 348,56 cm4 Iy = 254,56 cm4


fixing 6468 g/m Wx = 44,06 cm3 Wy = 32,82 cm3
106

E 85992 bracket Y 776 mm ex = 7,76 cm еy = 7,90 cm


0 mm ix = 3,81 cm iy = 3,26 cm
158

E 85 technical catalogue
01.2011 3.23
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X

2,01 m Ix = 822,14 cm4 Iy = 279,77 cm4


fixing 8397 g/m Wx = 74,74 cm3 Wy = 37,20 cm3
105

E 85900 bracket Y 871 mm ex = 8,00 cm еy = 11,00 cm


0 mm ix = 5,14 cm iy = 3,09 cm
220

6,01 m Ix = 836,65 cm4 Iy = 842,12 cm4


fixing 10260 g/m Wx = 79,68 cm3 Wy = 78,27 cm3
E 85993 bracket
150

1032 mm ex = 10,76 cm еy = 10,50 cm


Y
0 mm ix = 4,69 cm iy = 4,71 cm

210

2,01 m Ix = 907,18 cm4 Iy = 771,28 cm4


fixing 10972 g/m Wx = 86,40 cm3 Wy = 75,39 cm3
E 85918 bracket
140

693 mm ex = 10,23 cm еy = 10,50 cm


Y 0 mm ix = 4,73 cm iy = 4,36 cm

210

2,01 m Ix = 234,00 cm4 Iy = 152,96 cm4


fixing 4892 g/m Wx = 31,20 cm3 Wy = 19,39 cm3
E 85913 bracket
100

494 mm ex = 7,89 cm еy = 7,50 cm


Y
0 mm ix = 3,59 cm iy = 2,91 cm
150

2,01 m Ix = 85,63 cm4 Iy = 135,56 cm4


fixing 3458 g/m Wx = 13,96 cm3 Wy = 17,89 cm3
105

E 85967 bracket Y 415 mm ex = 7,58 cm еy = 6,13 cm


0 mm ix = 2,59 cm iy = 3,25 cm
84

suppl. 6,01 m
5

profile for 313 g/m


E 85901 fixing 26 65 mm
bracket 0 mm

E 85 technical catalogue
01.2011 3.24
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

suppl. 14.3 6,01 m


profie for X 2036 g/m
E 85903 fixing Y
271 mm
bracket 108 0 mm

X
5,00 m Ix = 37,13 cm4 Iy = 37,13 cm4
insert 1847 g/m Wx = 12,38 cm3 Wy = 12,38 cm3
7528 for E 85130
Y
239 mm ex = 3,00 cm еy = 3,00 cm
60

0 mm ix = 2,33 cm iy = 2,33 cm
60

6,01 m
suppl. 1246 g/m
E 85966 profile for
44.2

207 mm
louvers 0 mm
29.6

6,01 m
drainage 240 g/m
E 85911
40.3

profile 122 mm
0 mm
17.5

6,01 m
profile
13.8

283 g/m
E 85904 for spring 46 mm
connector 15.3 0 mm

6,01 m
spacer for 448 g/m
E 85290 etalbond
23

126 mm
21.1 0 mm

E 85 technical catalogue
01.2011 3.25
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

6,01 m

19
spacer for 400 g/m
E 85291 etalbond 134 mm
25.1 0 mm

6,01m
suppl. profile 176 g/m
7.5

E 85610 for sealing 65 mm


membrane 29.6 0 mm

6,01 m
suppl. profile
24.5

346 g/m
E 85611 for sealing 176 mm
membrane 0 mm
43

6,01 m
suppl. profile
24.5

381 g/m
E 85612 for sealing 170 mm
membrane 0 mm
43

6,01 m
wall 984 g/m
E 85620 attachment 277 mm
40

profile 0 mm
70

6,01 m
wall 999 g/m
E 85621 attachment 285 mm
40

profile 0 mm
74

E 85 technical catalogue
01.2011 3.26
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

25
6,01 m
cover cap 479 g/m
E 8700
60
anti-burglar 231 mm
111 mm

23
6,01 m
cover cap 460 g/m
E 8701
60

anti-burglar 223 mm
107 mm

6,01 m
9.6

pressure plate 554 g/m


E 8620 anti-burglar 168 mm
57.6 0 mm

6,01 m
flat bar 1350 g/m
10

50009 anti-burglar 120 mm


50 0 mm

6,01 m Ix = 21,00 cm4 Iy = 19,23 cm4


square tube 1816 g/m Wx = 8,84 cm3 Wy = 8,55 cm3
47001
45

anti-burglar 182 mm ex = 2,25 cm еy = 2,38 cm


0 mm ix = 1,77 cm iy = 1,69 cm
47.5

6,01 m
cover 1312 g/m
E 85727 cap
50

388 mm
251 mm
100

E 85 technical catalogue
01.2011 3.27
PROFILES

DRAWINGS SCALE 1:1


curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter

X 6,01 m Ix = 127,94 cm4 Iy = 28,07 cm4


reinforcement 2356 g/m Wx = 21,57 cm3 Wy = 12,36 cm3
Y
E 85801 for transom
45.4

355 mm ex = 2,27 cm еy = 5,93 cm


E 85306 0 mm ix = 3,83 cm iy = 1,79 cm
111

X 6,01 m Ix = 310,45 cm4 Iy = 37,86 cm4


reinforcement 2964 g/m Wx = 37,33 cm3 Wy = 16,68 cm3
Y
E 85802 for transom
45.4

445 mm ex = 2,27 cm еy = 8,32 cm


E 85357 0 mm ix = 5,32 cm iy = 1,86 cm
156

reinforced X 6,01 m Ix = 12,08 cm4 Iy = 3,44 cm4


glazing support Y 1250 g/m Wx = 4,45 cm3 Wy = 1,55 cm3
E 85803 for 2nd level
44.4

276 mm ex = 2,22 cm еy = 2,72 cm


transom 0 mm ix = 1,62 cm iy = 0,86 cm
51.5

reinforced X 6,01 m Ix = 3,50 cm4 Iy = 1,18 cm4


glazing support Y 889 g/m Wx = 1,89 cm3 Wy = 0,86 cm3
E 85804 for 3rd level
27.6

165 mm ex = 1,38 cm еy = 1,84 cm


transom 36 0 mm ix = 1,03 cm iy = 0,60 cm

6.4 6,01 m
15.6

reinforcement 210 g/m


E 85805 additional 44 mm
0 mm

X 6,01 m Ix = 26,27 cm4 Iy = 24,34 cm4


reinforced 2232 g/m Wx = 7,76 cm3 Wy = 10,68 cm3
Y
E 85905 transom
45.6

321 mm ex = 2,28 cm еy = 3,89 cm


connector 0 mm ix = 1,78 cm iy = 1,72 cm
60

E 85 technical catalogue
01.2011 3.28
curtain wall system E 85

mullions, inserts, connectors and flush transoms 2nd and 3rd level

2nd level 2nd level flush 3rd level 3rd level flush hidden
roof
code insert flush transom + suppl. flush transom + suppl.
connector
transom Profile transom profile
E 85100 - E 85960 E 85302 - E 85352 -
E 85101 E 85951 E 85960 E 85303 E 85300+E 85600 E 85353 E 85380+E 85600
E 85102 E 85952 E 85960 E 85304 E 85300+E 85601 E 85354 E 85380+E 85601
E 85103 E 85953 E 85960 E 85305 E 85300+E 85602 E 85355 E 85380+E 85602
E 85104 E 85954 E 85960 E 85306 E 85300+E 85603 E 85356 E 85380+E 85603
E 85105 E 85955 E 85960 E 85307 - E 85357 -
E 85106 E 85956 E 85969 - - E 85358 -
E 85107 E 85957 E 85969 - - E 85359 -
E 85108 E 85958 E 85969 - - E 85359 -
E 85109 E 85969 E 85969 - - E 85369 -

E 85 technical catalogue
01.2011 4.1
curtain wall system E85
mullions
24.5 5 144.5 6 194 6

10

2.8
2.5
20

10
insert E 85956

50

44.4
45
50

50
10
20 10 20
insert E 85957

10
10 10 10 10

20
16

E 85106 E 85107

2.8
2.5
10
16 180 200

24.5 196 216


66

2.5
24.5 8 155.5 12
50

3
10
19

20
E 85100

10
insert E 85958
4

44
50

50
10
insert E 85951
86
70

39

E 85101
10
20
4

E 85108
10

insert E 85952

3
106
90

59

E 85102 16 200
216
4

insert E 85953
126
110

79

E 85103 24.5 8 182.5 15


4

4
10

insert E 85954
146
130

20
99

E 85104 insert E 85969


10
4

42
50

50
10

insert E 85955
10
176
160

129

20

E 85105 E 85109
10
4

4
46 16 230
2 2
246
scale 1:1 50

E 85 technical catalogue
01.2011 4.2
curtain wall system E 85

split mullions, inserts and flush transoms 2nd and 3rd level

2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom Profile transom profile
E 85152 E 85972 E 85304 E 85300+E 85601 E 85354 E 85380+E 85601
E 85153 E 85973 E 85305 E 85300+E 85602 E 85355 E 85380+E 85602
E 85154 E 85974 E 85306 E 85300+E 85603 E 85356 E 85380+E 85603
E 85155 E 85975 E 85307 - E 85357 -

E 85 technical catalogue
01.2011 4.3
curtain wall system E 85
split mullions supplementary profiles for split mullions

suppl. profile E 85150


E 85150

68.8
45.8
90

16.3 32
32.7

insert E 85972

E 85152

insert E 85973
52.7

E 85153
110

insert E 85974
72.7

E 85154
130

mullion E 85155

insert E 85975
102.7

E 85155
13.5
160

E 85151
suppl. profile E 85151
22.5 32 mullion E 85155

scale 1:1

E 85 technical catalogue
01.2011 4.4
curtain wall system E 85
mullion for substructure & cover cap

50
E 85120
20 10 20

10 10 10 10
16

E 85350

E 85360 mullion E 85120

E 85300
24.5
35.3
2.5

E 85301/E 85351
81

65

E 85302/E 85352
38

26.4
27.7
2

cover cap E 19641


E 19641
19.5 11 19.5 7.5

appropriate transom 2nd and 3rd level

2nd level
code 3rd level transom
transom

E 85300 E 85350/E 85360


E 85120 E 85301 E 85351
E 85302 E 85352

scale 1:1

E 85 technical catalogue
01.2011 4.5
curtain wall system E 85
mullion 90°

20 10 10 10 15.5 40.5

10 10 10 10 15.5 24.5
16

40.5
24.5
2.5

15.5

15.5
106
90

10

10
2.5 2.5
60.5
10

10
60.5

10
10

20
2.5

10

E 85130 90 16
106
insert 7528

insert and flush transoms 2nd and 3rd level

2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom profile transom Profile
E 85130 7528 E 85304 E 85300+E85601 E 85354 E 85380+E 85601

scale 1:1

E 85 technical catalogue
01.2011 4.6
curtain wall system E 85
mullion 135°
cover cap E 85732
pressure plate E 85741

24
16

10
10

45°
118 90

1 6 .3

6 0 .8

119.7
insert E 85973

E 85135

135°
7 6 .9
76.9
22.5°

142.1

insert and flush transoms 2nd and 3rd level

2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom Profile transom profile
scale 1:1 E 85135 E 85973 E 85304 E 85300+E85601 E 85354 E 85380+E 85601

E 85 technical catalogue
01.2011 4.7
curtain wall system E 85
supplementary mullion profile

30°-90°

split rotating mullion

40.1
E 85140

50
any mullion

split rotating mullion with E 85140

30
10 20
16
36

26.5
23.3
55.6
19.6

E 85141

Appropriate transoms 2nd and 3rd level for E 85141

code 2nd level transom 3rd level transom

scale 1:1 E 85141 E 85300 E 85350/E 85360

E 85 technical catalogue
01.2011 4.8
curtain wall system E 85
inner supplementary mullion profile 90°

pressure plate E 85740

cover cap E 85731


any mullion
10.2

48
19.8
48.2

14.9

90
°

E 85142
3.3

14.9 19.8 10.2


3.3
48.2

any mullion

scale 1:1

E 85 technical catalogue
01.2011 4.9
curtain wall system E 85
outer supplementary mullion profile 90°

cover cap E 85713


pressure plate E 85700

35.7

44
4.4

.3
31.3
5 26.3

E 85143
26.3
31.3
35.7
4.4
5

pressure plate E 85700

spacer E 85655 cover cap E 85713

any mullion

scale 1:1

E 85 technical catalogue
01.2011 4.10
curtain wall system E 85

flush transoms 2nd and 3rd level

3rd level 2nd level flush 3rd level flush hidden


code flush transom + suppl. transom + suppl.
transom profile profile
E 85300 - - -
E 85301 E 85351 - -
E 85302 E 85352 - -
E 85303 E 85353 E 85300+E 85600 E 85380+E 85600
E 85304 E 85354 E 85300+E 85601 E 85380+E 85601
E 85305 E 85355 E 85300+E 85602 E 85380+E 85602
E 85306 E 85356 E 85300+E 85603 E 85380+E 85603
E 85307 E 85357 - -

E 85 technical catalogue
01.2011 4.11
curtain wall system E85

2nd level transom 2nd level transoms

2.5 2 1.8 1.8 2 2 2 2 2


12.5 13 12.2 32.2 52 72 92 112 142
E 85300

1.5

2
10

10
23.5
20

20
∅1
7
10

10
∅1
4

47

46
50

50

50
10

10
10

10
20

20
E 85301 E 85302 E 85303 E 85304 E 85305 E 85306 E 85307
10

10

2
1.5
16 15 16 29 49 69 89 109 129 159
31 45 65 85 105 125 145 175

3rd level transom 3rd level transoms

2 2 2 2 2 2 2 2 2 2
6 7 27 47 67 87 107 127 157 177 197 226 3
E 85350 E 85360

2
11

11
20

20

∅1 23.5
7
9

∅1
4

46
50

50

50
10

10
9

9
20

20

E 85351 E 85352 E 85353 E 85354 E 85355 E 85356 E 85357 E 85358 E 85359 E 85369
11

11

2
10 6 10 15 35 55 75 95 115 135 165 185 205 235
16 25 45 65 85 105 125 145 175 195 215 245

scale 1:1

E 85 technical catalogue
01.2011 4.12
curtain wall system E 85
2nd level supplementary transoms

2.5 1.8 1.8 1.8 1.8


15.2 49.5 69.5 89.5 109.5
transom E 85300

1.5

1.4
55.2
58

55

58
15.2

E 85600 E 85601 E 85602 E 85603

1.4
1.5
69 89 109 129

3rd level hidden transom

2
6 13.2

2
11

46
50
28

50
11
E 85380

2
21.2

scale 1:1

E 85 technical catalogue
01.2011 4.13
curtain wall system E 85
3rd level split transom for conservatory

transom E 85370
suppl. profile E 85670

30°-9

10
10
40
9
27.5

E 85370

11
55 10
65

supplementary profile for E 85370 2nd level split transom for conservatory
transom E 85320

51

30°-9

12

E 85320
68.9
13.2

10
42
32

10

E 85670
20
10

29 16
45

scale 1:1

E 85 technical catalogue
01.2011 4.14
curtain wall system E 85
frame for thermo-break projected and parallel opening windows

38.5 extruded al. joint corner bracket 54 457 or 53 302


54.5

RAL 9005
E 85410
16

60 30.3
90.3

appropriate transom 2nd and 3rd level for frame operating rods

19.7
code 2nd level transom 3rd level transom
4.3

E 85303 E 85353
E 2308
E 85304 E 85354
E 85305 E 85355
E 85306 E 85356
E 85410 23.5
E 85307 E 85357
- E 85358
- E 85359
4.7

- E 85369
E 2309
note: frame E 85410 is suitable for
sashes E 85210 and E 85211 spacer

19

E 85915
4.8

scale 1:1

E 85 technical catalogue
01.2011 4.15
curtain wall system E 85
sash for thermo-break projected window

extruded al. joint corner bracket 54 461


79
56.9 22.1

external glass support


for structural glazing

18.9
20

E 85210
49.5

sash E 85210
13

30.6
extruded al. joint corner bracket 54 462 RAL 9005 19.2
12.8 6.4
16.5

E 85614

4.4
11 23 20 17.1 7.9

27.9
21.5
glass support E 85615

2
sash for thermo-break parallel opening window

extruded al. joint corner bracket 54 461


79
56.9 22.1

external glass support


for cover cap
18.9
20

E 85211
49.5

12

sash E 85210
30.6

extruded al. joint corner bracket 54 462 RAL 9005 13.5


17.5

4.6

E 85615
9
15

11 23 23.4 13.7 7.9


6

glass support E 85615


11.2 9.2
1.6
22

scale 1:1

E 85 technical catalogue
01.2011 4.16
curtain wall system E 85
sash profile for projected window

extruded al. joint corner bracket 54 457 or 53 302

57.8
22.8 40.8 17

extruded al. joint corner bracket 54 459


E 85200
55.3
16.5
16

33.6 24.2

frame for projected window


61.4
38.9 22.5
17
49

32

E 85400

extruded al. joint corner bracket 54 458


extruded al. joint corner bracket 54 457 or 53 302

scale 1:1

E 85 technical catalogue
01.2011 4.17
curtain wall system E85
pressure plates

5
26. E 85706
10.5
E 85703
E 85700 30°
7.5°

25.9

35.9
10.2

14
47.6
70.7

165° 120°
97

E 85707

.9

37.5
E 85701 36
15.8 E 85704

44
°
10.2
7.4

28.2
15°

46.4
14

14
80.8 105°
150° 110.2

E 85708
E 85705
41.6 2 1 .2

31.6
22.5°

45°

.2
47

53.8
13.4
23.6

14

E 85745
10.2

135°
89.8

47.6 90°

14
119.2

scale 1:1

E 85 technical catalogue
01.2011 4.18
curtain wall system E 85
cover caps

7.5
18
E 85721

10.5
50

∅4

25
40
1.3 E 85722

15
50

∅8

129
160
69
100
∅4 ∅4
1.4 E 85723 1.4 E 85724

47.4 47.4

16.3
1.4 1.4

31

31
50 50

scale 1:1

E 85 technical catalogue
01.2011 4.19
curtain wall system E85
cover caps
47
13.8 E 85751
E 85711 E 85716 E 85718

4.9
12

28.9
50 16.8 14.4 16.8
E 85750
45.4

10.2
60
47.4
E 85712 47.4

16.3
48
1.5

15

24.3
50 7.1 10 7.1
50

5.9

5
E 85719
47.4
E 85713
6.3

165
12.5 25 12.5
20

7.2 5.1

10.5
12.3
E 85727
E 85709
50
17.4 15.2 17.4
50
47.4
E 85714
11.3

25

70.4

E 85730

12
50
100

50

50
47.4
E 85715
47.4
16.3
16.3

E 85720 E 85702
1.5
30

25

5.5
47.4

50
50
50 50
scale 1:1

E 85 technical catalogue
01.2011 4.20
curtain wall system E 85
cover caps & pressure plates

cover cap E 85731


30
E 85740 12 18
cover cap E 85732

E 85741

18
30

1 3 .5

1 3 .5
12
42

22.5°
.2
90
46.2

°
45°

32

E 85731 21.2 10.8

31.5

10.8
E 85732

32

2 0 .6

2 0 .6
21.2

22.5°
45
90
50

°
pressure plate E 85740 45° pressure plate E 85741

E 85791 inox
E 85790 inox

20
15
51 51

note: cover caps E 85790 and E 85791 have to be used with special pressure plate!

scale 1:1

E 85 technical catalogue
01.2011 4.21
curtain wall system E 85
spacers for structural glazing

14.8 E 85990

6
6.8

9.2
24
14.8

19.3

glazing clips

43.6 43.6

E 85920 E 85903
8.6
5

5
10

15.3 13 15.3 15.3 13 15.3

spacers for structural glazing

16
11
9.3

7.3
9

33 501 33 879

glazing clip for 33 879

22
4
8.9

33 881

10 12

scale 1:1

E 85 technical catalogue
01.2011 4.22
curtain wall system E 85
transom connectors

∅4
transom connector E 85908
45.6

45.6
E 85906
E 85907

40 45.7

base for transom connectors


transom connector E 85907
5
∅4
10
45
25

42.6
10

E 85908
E 85994
43.2 6.5

reinforced transom connector


60

profile for spring connector


15.3
1.5
13.8
45.6
13.8

E 85905
E 85904

scale 1:1

E 85 technical catalogue
01.2011 4.23
curtain wall system E 85
inserts

45.2

12.6
4
∅6.
12.6

4
∅6.
38.2

18.4

E 85951
mullion E 85101
7.2

38.4

E 85952
mullion E 85102
58.2

7.2

143.7

123.9
58.4

E 85953
mullion E 85103
7.2
78.2

78.4

E 85954
mullion E 85104
7.2
98.2

mullion E 85106

20
108.4

E 85956
E 85955
mullion E 85105
128.2

7.2
7.2

45.2 44.2

scale 1:1

E 85 technical catalogue
01.2011 4.24
curtain wall system E 85
inserts

12.6

12.6
4
∅6. 4
∅6.
20 20

154.7
163.7

134.9
143.9

E 85958
mullion E 85108
E 85957
mullion E 85107
7.2
7.2

43.6 43.2
scale 1:1

E 85 technical catalogue
01.2011 4.25
curtain wall system E 85
roof connectors / insert for E 85109
8.2 28.8 8.2

8
8.2
6.2 28.4 6.2

8
8.2
∅5

∅5
183.4
216

149.1
181.7

mullion E 85109

E 85960 E 85969

29.2 28.8

7.4 14.4 7.4 7.2 14.4 7.2


8.4

8.4
8

scale 1:1
45.2 40.8

E 85 technical catalogue
01.2011 4.26
curtain wall system E 85
inserts for half mullions

6.8

∅6.4
31.9

18.3

mullion E 85152

E 85972
6.8
38.3

mullion E 85153
51.9

E 85973
6.8
58.3

mullion E 85154
71.9

E 85974
6.8

mullion E 85155
88.3
101.9

E 85975
6.8

15.5

scale 1:1

E 85 technical catalogue
01.2011 4.27
curtain wall system E 85
reinforcement for transoms

E 85802

E 85801
156
111

transom E 85357

transom E 85306

45.4 45.4

for transom E 85306 only! for transom E 85357 only!

scale 1:1

E 85 technical catalogue
01.2011 4.28
curtain wall system E 85
spacers

°
37.5
14.1
E 85640 7.5° E 85650 E 85654

7.5
7.2
6

6
10 10 10

E 8611
E 85651
15°
10

8.6

45°
6.2

17.1
E 85655

8.5
10 10

10

E 85641
22.5°

E 85652
12

10.1

6.5

10 10

E 85642
30°
18

E 85653
11.9

6.9

10 10

supplementary profile for louvers drainage profile


29.6 17.5
7 15.6 7 11.4 6.1
2
0.9
15.8

15.5

15.3
32

40.3

E 85911
44.2

23.9

23
R3

24.4
5
7.2

E 85966
9.6 10.4 9.6

scale 1:1

E 85 technical catalogue
01.2011 4.29
curtain wall system E 85
2nd level glazing supports 3rd level glazing supports
44.9
6.3 38.6 29.8
3.3
a = 32 a = 26.5
17.2

E 85902 E 85912

9.7
48.9
6.3 42.6 33.3
3.3
a = 36 a = 30
17.2

E 85916 E 85917

9.7
54.9
6.3 48.6
39.8
a = 42 3.3
a = 36.5
17.2

E 85910 E 85914
9.7

51.5
36

E 85803 E 85804
44.4

27.6
15.6

15.6

2nd level reinforced 3rd level reinforced


glazing support glazing support

E 85805
accsessory utility lenght loadbearing
code
code a capacity
15.6

E 85902 071 182 32 mm 1530 N


E 85916 071 184 36 mm 1200 N
E 85910 071 183 41 mm 650 N 6.4
E 85912 071 180 26,5 mm 1175 N
E 85917 071 185 30 mm 910 N
E 85914 071 181 36,5 mm 740 N
scale 1:1

E 85 technical catalogue
01.2011 4.30
curtain wall system E 85
wall attachment profiles supplementary profile for holding
sealing membrane

46 28
150°
60°
20 E 85610

7.5

3
37.5

10.6
40

20.8
29.6

E 85621
2.5

74

10

13.5
E 85611

24.5
14.5

11
46 24 5 38
43
37.5

33 10
40

10

13.5
E 85612
E 85620
2.5

24.5
14.5

70 11

5 38
43
spacers for etalbond structural glazing

E 85291
E 85290 25.1
21.1 7
5.7
9.3

11.4

15
19

19
18.7
23

5.7

12
8

12.1
7

scale 1:1

E 85 technical catalogue
01.2011 4.31
COVER CAP

SECTIONS DETAILS
curtain wall system E 85
mullion with 2nd level transom

50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713

pressure plate E 85700
5

butyl seal 133 553


20
25

gasket 130 500
15
6 5

min 6
28

16
6
10

10

gasket 130 470


thermal insulation spacer 80 172

gasket 76 651

flange 76 674
190

5 5 tapping screw
DIN 7981 ST4.8x19-C-H
89

3 3
15 10 10 15
130

18 20 18
fixing part 71 113

transom E 85304
6
mullion E 85104
41

50
E85CP5.1

scale 3/4

E 85 technical catalogue
01.2011 5.1
curtain wall system E 85
transom 2nd level drainage

cover cap E 85712
pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 470
flange 76 674
min 6
15
10

56.3
50

50
10

5
15

fixing part 71 113
transom E 85304

gasket 76 651 behind


thermal insulation spacer 80 172

glazing shim 71 183

PVC spacer 9020
5 15 5 6 16 6 10 89 41

25 28 10 130
mullion E 85104

note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
E85CP5.2

butyl seal tape in both directions.

scale 3/4

E 85 technical catalogue
01.2011 5.2
curtain wall system E 85
transom 2nd level drainage with supplementary transom

cover cap E 85712
pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 470
min 6

tapping screw
DIN 7981 ST4.8x19-C-H
15
10
50

58
10

tapping screw
15

DIN 7981 ST4.8x19-C-H

transom profile E 85602


transom E 85300
EPDM flange 76 653

thermal insulation spacer 80 172

glazing shim 71 184

PVC spacer 9020
5 15 5 6 16 6 10 109 21

25 28 10 130
mullion E 85104

note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
E85CP5.3

butyl seal tape in both directions.

scale 3/4

E 85 technical catalogue
01.2011 5.3
curtain wall system E 85
transom 3rd level drainage

cover cap E 85712


pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 474
glazing shim 71 185
15
10

56.3
50

50
10

5
15

flange 76 664
fixing part 71 113
transom E 85354
silicone flange 76 680 behind
thermal insulation spacer 80 172

PVC spacer 9020

mullion E 85104
5 15 5 28 4 95 41

25 6 16 6 10 130

note:
E85CP5.4

in case of 3rd level drainage, it is obligatory to use butyl seal tape in both directions.

scale 3/4

E 85 technical catalogue
01.2011 5.4
curtain wall system E 85
projected thermo-break window

gasket 130 706 50


1 cover cap E 85713
gasket 130 457 9 14.4 14.2 10.8 10 15
33 45.8 pressure plate E 85700
glass support E 85615
gasket 130 500
gasket 130 131

structural seal 6 mm

25
norton tape 6x6.4 mm
6

6
6

butyl seal 133 533


28

28
16

16
31
16
6

6
6
7

10
7

gasket 130 176


sash E 85210 gasket 130 470
spacer 700R
gasket 130 461 thermal insulation spacer 80 172
friction arm 400R/600R
56

mullion E 85104
operating rod E 2308
striker 255 602
striker 255 603

gasket 130 180


frame E 85410 2
20 8 38.5 15 10 10 15
36

gasket 130 413 3


18 20 18
transom E 85304
77
41

E85CP5.5

50

scale 3/4

E 85 technical catalogue
01.2011 5.5
curtain wall system E 85
projected thermo-break window with 2nd level transom

28
20 5 6 16 6 7 56 77

gasket 130 176/P6


sash E 85210
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
8 DIN 7981 ST4.8x32-M-Z
gasket 130 131 gasket 130 180
33

striker 255 602


gasket 130 457 striker 255 603
38.5

frame E 85410
gasket 130 706
9

gasket 130 413


transom E 85304
14.4

2
45.8

36
6
50

31 7

glazing shim 71 183 gasket 130 470


thermal insulation spacer 80 172
gasket 130 500

5 15 5 6 16 6 10 89 41
20 5 28 10 130
E85CP5.6

scale 3/4

E 85 technical catalogue
01.2011 5.6
curtain wall system E 85
projected thermo-break window with 3rd level transom

28
20 5 6 16 6 7 56 77

gasket 130 176


sash E 85210
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 131 gasket 130 180
33

striker 255 602


gasket 130 706 striker 255 603
38.5

frame E 85410
9

gasket 130 413


transom E 85304
14.4

2
45.8

36
50

31
1

glazing shim 71 185


gasket 130 474

gasket 130 500 thermal insulation spacer 80 172

5 15 5 6 16 6 10 89 41
E85CP5.7

scale 3/4

E 85 technical catalogue
01.2011 5.7
curtain wall system E 85
parallel opening thermo-break window

gasket 130 706 50


1
gasket 130 457 9 14.4 14.2 10.8 10 15
33 45.8 cover cap E 85713
glass support E 85615
pressure plate E 85700
gasket 130 131

structural seal 6 mm gasket 130 500

25
norton tape 6x6.4 mm
6

6
6

butyl seal 133 533


28

28
16

16
31
16
6

6
6
7

10
7

gasket 130 176 / P6


sash E 85211 gasket 130 470
23.5

gasket 130 461


thermal insulation spacer 80 172
friction arm 900R/900L
56

operating rod E 2308

gasket 130 180


frame E 85410 2
20 8 38.5 15 10 10 15
36

3
gasket 130 413 18 20 18
transom E 85304
77

mullion E 85104
41

E85CP5.8

50
scale 3/4

E 85 technical catalogue
01.2011 5.8
curtain wall system E 85
parallel opening thermo-break window with 2nd level transom

28
20 5 6 16 6 7 56 77

gasket 130 176/P6


sash E 85211
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8 gasket 130 180
gasket 130 131
33

friction arm 900R/900L


gasket 130 457 frame E 85410
38.5

gasket 130 706 gasket 130 413


9

transom E 85304
14.4

2
45.8

36
6
50

31 7

glazing shim 71 183 gasket 130 470


thermal insulation spacer 80 172
gasket 130 500

5 15 5 6 16 6 10 89 41
20 5 28 10 130
E85CP5.9

scale 3/4

E 85 technical catalogue
01.2011 5.9
curtain wall system E 85
parallel opening thermo-break window with 3rd level transom

28
20 5 6 16 6 7 56 77

gasket 130 176 / P6


sash E 85211

20
gasket 130 461
norton tape 6x6.4 mm
operating rod E 2308
structural seal 6 mm self drilling screw
DIN 7981 ST4.8x32-M-Z
gasket 130 131 8 gasket 130 180
33

friction arm 900R/900L


gasket 130 706 frame E 85410
38.5

gasket 130 413


9

transom E 85304
14.4

2
45.8

36
50

31
1

glazing shim 71 180


gasket 130 474

gasket 130 500 thermal insulation spacer 80 172

5 15 5 6 16 6 10 89 41
E85CP5.10

scale 3/4

E 85 technical catalogue
01.2011 5.10
curtain wall system E 85
projected window

tapping screw
DIN 7981 ST5.5x45-C-H cover cap E 85713
thermal insulation spacer 80 172 50
1 1
thermal insulation spacer 80 177 25 10 15 pressure plate E 85700
structural seal 6 mm butyl seal 133 553
norton tape 6x6.4 mm

25
37.3 10
gasket 130 500
20

6
26

14

28
16
26

4
6

6
4

12

10
gasket 130 175
gasket 130 470
profile 8902
39.9

gasket 130 180


friction arm 400R/600R
10.3

spacer E 85640

sash E 85200
14.3 51
gasket 130 180 2
65.3 3 3
frame E 85400
46.9

15 10 10 15
gasket 130 458
18 20 18
gasket 130 409

transom E 85304
mullion E 85104
41

E85CP5.11

scale 3/4

E 85 technical catalogue
01.2011 5.11
curtain wall system E 85
projected window with 2nd level transom

gasket 130 175


6 14 6

25 26 4 39.9 10.3 87.9


gasket 130 180
sash E 85200

14.3
4

norton tape 6x6.4 mm gasket 130 180


structural seal 6 mm 65.3
37.3

51

gasket 130 458


frame E 85400
gasket 130 409
10

spacer E 85640
50

thermal insulation spacer 80 177

gasket 130 470


thermal insulation spacer 80 172
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 500
transom E 85304
mullion E 85104
5 15 5 6 16 6 10 89 41
20 5 28 10 130
E85CP5.12

scale 3/4

E 85 technical catalogue
01.2011 5.12
curtain wall system E 85
projected window with 3rd level transom

gasket 130 175


6 14 6

25 26 4 39.9 10.3 87.9


gasket 130 180
sash E 85200

14.3
4

norton tape 6x6.4 mm gasket 130 180


structural seal 6 mm
65.3
37.3

51

gasket 130 458


frame E 85400
gasket 130 409
10

gasket 130 500
2

butyl seal 133 553


50

thermal insulation spacer 80 177

gasket 130 474


thermal insulation spacer 80 172
tapping screw
DIN 7981 ST5.5x45-C-H
transom E 85354
mullion E 85104

5 15 5 6 16 6 4 6 89 41
20 5 28 10 130
E85CP5.13

scale 3/4

E 85 technical catalogue
01.2011 5.13
curtain wall system E 85
window in curtain wall

thermal insulation spacer 80 172
102 50
1
41.5 5 55.5 14 11 10 15
gasket 130 470 cover cap E 85713
additional profile E 85641
pressure plate E 85700
gasket 130 152

gasket 130 161


gasket 130 500
15

gasket 130 411


5
8

16.5
6

9.5
28
16

12
6

gasket 130 470


39

gasket 130 413


gasket 130 177
21 53.5 26.5
2
glazing bead 5380 103

sash E 2482
gasket 130 131
100.5

frame E 2424

transom E 85304
mullion E 85104
E85CP5.14

scale 3/4

E 85 technical catalogue
01.2011 5.14
curtain wall system E 85
window in curtain wall with 2nd level transom

28

20 5 8 6 16 6 39
gasket 130 177
gasket 130 411 glazing bead 5380

21
42.5

gasket 130 152


5

53.5
103

103
gasket 130 161

sash E 2482
55.5

additional profile E 85641 gasket 130 131

frame E 2424
26.5

gasket 130 470


gasket 130 413
2

59.5
50

tapping screw 16.5 9.5 12 glazing shim 71 184


DIN 7981 ST5.5x45-C-H
PVC spacer 9020

thermal insulation spacer 80 172
transom E 85304
15 5 28 10 gasket 130 470

mullion E 85104
E85CP5.15

scale 3/4

E 85 technical catalogue
01.2011 5.15
curtain wall system E 85
window in curtain wall with 3rd level transom

28

20 5 8 6 16 6 39
gasket 130 177
gasket 130 411 glazing bead 5380

21
41.5

gasket 130 152


5

53.5

103
102

gasket 130 161

sash E 2482
55.5

additional profile E 85640 gasket 130 131

frame E 2424
26.5

gasket 130 470


gasket 130 413
2

59.5
50

tapping screw 16.5 9.5 6 glazing shim 71 185


DIN 7981 ST5.5x45-C-H
PVC spacer 9020

thermal insulation spacer 80 172
transom E 85354

gasket 130 474


15 5 28 4 6
E85CP5.16

mullion E 85104

scale 3/4

E 85 technical catalogue
01.2011 5.16
curtain wall system E 85
door in curtain wall

cover cap E 85713


pressure plate E 85700
tapping screw
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 172
134.9 50
2 1
92 5 35.9 18.3 6.7 10 15
gasket 130 470
gasket 130 152
gasket 130 411
gasket 130 177 17.1
gasket 130 500
8
6

butil seal 133 550


28

28
16
6

10
31.6

gasket 130 470

21 46 5 60.9
2
134.9
glazing bead E 5307 gasket 130 413
sash E 2443
gasket 130 152
frame E 2445
108.4

transom E 85304

mullion E 85104
E85CP5.17

scale 3/4

E 85 technical catalogue
01.2011 5.17
curtain wall system E 85
door in curtain wall with 2nd level transom

tapping screw
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 172
glazing shim 71 183

15 5 28 10 transom E 85304
15
10
50

6.7
18.3
2

gasket 130 413


12.1 28 10 67.4 41
gasket 130 470
35.9

mullion E 85104
60.9

frame E 2445
5
134.9

134.9
5

gasket 130 152


92

46

sash E 2443

glazing bead E 5307


21

8 6 16 6 31.6
E85CP5.18

gasket 130 177


28 gasket 130 411
scale 3/4

E 85 technical catalogue
01.2011 5.18
curtain wall system E 85
door in curtain wall with 3rd level transom

tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 474
thermal insulation spacer 80 172
glazing shim 71 185
15 5 28 10 transom E 85354
15
10
50

6.7
18.3
2

gasket 130 413


2

12.1 28 10 67.4 41
35.9

gasket 130 474


60.9

frame E 2445
5

mullion E 85104
134.9

134.9
5

gasket 130 152


92

46

sash E 2443

glazing bead E 5307


21

8 6 16 6 31.6
E85CP5.19

gasket 130 177


28 gasket 130 411
scale 3/4

E 85 technical catalogue
01.2011 5.19
curtain wall system E 85
split mullion

50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713

pressure plate E 85700
5

butyl seal 133 553


20
25

gasket 130 500
15
6 5

min 6
28

16
6
10

10

gasket 130 470


15 10 10 15 thermal insulation spacer 80 172
1 1
gasket 76 651
16 20 16
173

flange 76 674
tapping screw
DIN 7981 ST4.8x19-C-H
gasket 130 198
89

gasket 130 199


11.5 32 6.5
110

supplementary profile E 85150


mullion E 85153

fixing part 71 113

transom E 85304
21

self-drilling screw
DIN 7981 ST3.5x18-M-Z
supplementary profile E 85151
22.5 5 22.5
gasket 130 199
50
E85CP5.20

scale 3/4

E 85 technical catalogue
01.2011 5.20
curtain wall system E 85
mullion for substructure

50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713
pressure plate E 85700
5

butyl seal 133 553

25
gasket 130 500
15
5

6
28
16
6
10

gasket 130 470


128

thermal insulation spacer 80 172
103

29

gasket 76 651
transom E 85301
flange 76 671
tapping screw
DIN 7981 ST4.8x19-C-H
36

mullion E 85120

cap E 19641
7.5

nut cheese head screw
DIN 934-A2-70 DIN 931 M8x30-A2-70
washer spring washer
DIN 125 ∅ 8-A2-70 DIN 127 ∅8-A2-70
PVC
bush ∅10x2
E85CP5.21

scale 3/4

E 85 technical catalogue
01.2011 5.21
curtain wall system E 85
outer corner 90°
90º
etalbond
hard insulation 20 mm

4 seal 4 mm
self drilling screw
DIN 7981 ST3.5x18-M-Z

aluminium sheet 2 mm
1
4.33

cover cap E 85713


tapping screw
DIN 7981 ST5.5x45-C-H
pressure plate E 85700
gasket 130 500
butyl seal 133 553
etalbond

25
hard insulation 20 mm
soft insulation 31.5 mm

75
1
4.33

31.5 4 20 4 25

mullion E 85130
blind rivet
10

DIN 7337 A4.8x8-A


thermal insulation spacer 80 177
15
50
10
15
1

flange 76 674
gasket 076 651

gasket 130 457
1 transom E 85304
E85CP5.22

90 7 6 16 6 20 5
28 25
scale 3/4

E 85 technical catalogue
01.2011 5.22
curtain wall system E 85
outer corner 90°
90º

94 10 6
100
seal 10 mm
silicone coating

soft insulation 40 mm
etalbond

min 6
min 6

100
110
mullion E 85130

tapping screw
DIN 7981 ST4.8x19-C-H

gasket 076 651

gasket 130 457

transom E 85304
1

90 7 6 16 6 5 15
28 5 15

note:
it is necessary to calculate
E85CP5.23

measures for each project

scale 3/4

E 85 technical catalogue
01.2011 5.23
curtain wall system E 85
outer corner 90°
90º

etalbond
hard insulation
thermal insulation spacer 80 174 50
suppl. mullion profile E 85143 15 10 15 10 20.4 25
gasket 130 457

spacer E 85655 35.4

25
20.4
35.4

10
tapping screw

15
DIN 7981 ST5.5x45-C-H

50
10
15

transom E 85354 28
E85CP5.24

89 7 6 16 6

scale 3/4

E 85 technical catalogue
01.2011 5.24
curtain wall system E 85
outer corner 90°
90°
etalbond
hard insulation 20 mm
4

seal 4 mm
self-drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.36

50 165
1 tapping screw
15 10 15 10 DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
5

thermal insulation spacer 80 177


hard insulation 20
15

etalbond
6 5

28
16
6
7

10 152 4 20 4
28

gasket 130 457

hard insulation 40 mm
89

165
1
4.36
self-drilling screw
DIN 7981 ST4.8x19-M-Z
240

L-profile section 4065
blind rivet
DIN 7337 A4.8x8-A
41

10
15
50

50
10
15
1

E85CP5.25

not to scale

E 85 technical catalogue
01.2011 5.25
curtain wall system E 85
outer corner 90°
90°

max 500
tapping screw
DIN 7981 ST5.5x45-C-H 22 10 6 5 15
5

thermal Insulation spacer 80 174


20

seal 10 mm
15
5
6 5

min 6

23
28
16
6
7
7

10 28
seal 10 mm

gasket 130 457

welded seam 3 mm
89
130

flange 76 674

max 500
transom E 85304

mullion E 85104
41

note:
the glass thickness should be
E85CP5.26

checked by the facade engineer

not to scale

E 85 technical catalogue
01.2011 5.26
curtain wall system E 85
inner corner 90°

90°

gasket 130 500

pressure plate E 85700

cover cap E 85713

50
tapping screw
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174 min 5
min 5

gasket 130 457

3
5

gasket 130 457
30
25

15

30 blind rivet
73

DIN 7337 A4.8x8-A


6 5

58

65

thermal insulation spacer 80 177

hard insulation 20 mm
28

16

etalbond
6
7

73

154
151
58

65 130
190

welded seam 3 mm
89

flange 76 674

mullion E 85104
130

130

transom E 85304

50 3 151

154
41

E85CP5.27

not to scale

E 85 technical catalogue
01.2011 5.27
curtain wall system E 85
inner corner 90°

90°

gasket 130 500
cover cap E 85731

pressure plate E 85740


6
28

16
6

15 130
7

145

suppl. mullion profile E 85142
thermal insulation spacer 80 172

tapping screw
DIN 7981 ST5.5x45-C-H

tapping screw
89

DIN 7981 ST5.5x16-C-H
130

41

E85CP5.28

scale 3/4

E 85 technical catalogue
01.2011 5.28
curtain wall system E 85
outer corner 45° - 150°
32 45º-150º
etalbond
soft insulation 24 mm

4
seal 4 mm
self drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.41

thermal insulation spacer 80 177


tapping screw
DIN 7981 ST5.5x45-C-H 50 etalbond
soft insulation 24 mm

thermal insulation spacer 80 174
4
6

1
gasket 130 457 4.41
28
16

24
32

50
6

32
4

self drilling screw
DIN 7981 ST4.8x19-M-Z
L-profile section 4010 Aluminum

aluminium sheet 2 mm

supplementary profile E 85150

gasket 130 199


membrane 1 mm

mullion E 85153

gasket 130 198

transom E 85304 gasket 130 199

4 5°
-150
°
E85CP5.29

scale 3/4

E 85 technical catalogue
01.2011 5.29
curtain wall system E 85
inner corner 135°

135°

tapping screw
DIN 7981 ST5.5x38-C-H
cover cap E 85732
pressure plate E 85741
gasket 130 500

21.6
26.6
6 5
28
16
6
7
7

gasket 130 457

flange 76 674
5
thermal insulation spacer 80 174
tapping screw
DIN 7981 ST4.8x19-C-H
89
90

mullion E 85135

135°
1

transom E 85304
E85CP5.30

scale 3/4

E 85 technical catalogue
01.2011 5.30
curtain wall system E 85
outer corner 30°-90°
30º-90º

L-profile section 4134
etalbond

soft insulation
30°-90°
cover cap E 85713
tapping screw
DIN 7981 ST5.5x38-C-H

pressure plate E 85700
butyl seal 133 553
gasket 130 500
butyl seal
self drilling screw
DIN 7981 ST4.8x19-M-Z

6
16
28
6
7
15
9.5

transom E 85300

split rotating mullion E 85141


suppl. mullion E 85140

tapping screw
DIN 7981 ST5.5x32-C-H
90

mullion E 85102
E85CP5.31

scale 3/4

E 85 technical catalogue
01.2011 5.31
curtain wall system E 85
polygonal facade with outer angle max 5°
50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15 cover cap E 85713
pressure plate E 85700

butyl seal 133 553


15
20

gasket 130 500
5 6
16
28

6 4

gasket 130 470


thermal insulation spacer 80 172
39

35

flange 76 661

3 15 10 10 15 3 transom E 85351
mullion E 85101

polygonal facade with inner angle max 5°


50 1 tapping screw
1 DIN 7981 ST5.5x45-C-H
15 10 10 15 cover cap E 85713
pressure plate E 85700

butyl seal 133 553


15
20

gasket 130 500
6 5
28

16
4 6

gasket 130 470


39

thermal insulation spacer 80 172
35

flange 76 661

transom E 85351
3 15 10 10 15 3
mullion E 85101
E85CP5.32

scale 3/4

E 85 technical catalogue
01.2011 5.32
curtain wall system E 85
outer angles 0°~15°

tapping screw
DIN 7981 ST5.5x55-C-H
cover cap E 85711
pressure plate E 85703

butyl seal 133 553


0°-15°
gasket 130 500
12
17

5 6
16
28

6 4
4

gasket 130 474


5 10 5
spacer E 85650
thermal insulation spacer 80 172

tapping screw
outer angles 7.5°~22.5° DIN 7981 ST5.5x55-C-H
cover cap E 85711
pressure plate E 85704
butyl seal 133 553
7.5°-22.5°
gasket 130 500
12
17

5 6
16
28

6 4
4

5 10 5
gasket 130 474
spacer E 85651

thermal insulation spacer 80 172


E85CP5.33

scale 3/4

E 85 technical catalogue
01.2011 5.33
curtain wall system E 85
outer angles 15°~30°

tapping screw
DIN 7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85705

butyl seal 133 553


15°-30°

gasket 130 500

thermal insulation spacer 80 172


gasket 130 474
spacer E 85652
12
17

5
6
16
28

6 4

5 10 5
4

tapping screw
DIN 7981 ST5.5x60-C-H
outer angles 22.5°~37.5° cover cap E 85711

pressure plate E 85706


22.5°

butyl seal 133 553


-37.5

gasket 130 500
°

thermal insulation spacer 80 172

gasket 130 474


12

spacer E 85653
17

5
6
16
28

6
4
4

5 10 5
E85CP5.34

scale 3/4

E 85 technical catalogue
01.2011 5.34
curtain wall system E 85
outer angles 30°~45°

tapping screw
DIN 7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85707

butyl seal 133 553


gasket 130 500
30°-
45°

thermal insulation spacer 80 172

gasket 130 474

spacer E 85654
12
17

5
6
16
28

6
4

5 10 5
4

outer angles 37.5°~52.5° tapping screw


DIN 7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85708

butyl seal 133 553


3 7. 5

thermal insulation spacer 80 172


°-52
.5°

gasket 130 500
gasket 130 474

spacer E 85655`
12
5
17

6
16
28

6
4

5 10 5
4

E85CP5.35

scale 3/4

E 85 technical catalogue
01.2011 5.35
curtain wall system E 85
roof connector

tapping screw
DIN 7981 ST5.5x68-C-H
cover cap E 85711

pressure plate E 85706


butyl seal
gasket 130 500

thermal insulation spacer 80 172


2

gasket 130 470


12

spacer E 85653
19

5
6

0.3
14
5
28.
35

4
44
4

transom E 85305
mullion connector E 85960 below

mullion E 85104
E85CP5.36

scale 3/4

E 85 technical catalogue
01.2011 5.36
01.2011
scale 1:2
50 255 50

E 85 technical catalogue
1 1 tapping screw 1 1
15 10 10 15 DIN 7981 ST5.5x45-C-H 15 10 10 15
cover cap E 85713
pressure plate E 85700

butyl seal 133 553

15
gasket 130 500
curtain wall system

6 5
16

28
6

10
10
gasket 130 470 transom E 85305
thermal insulation spacer 80 172 mullion E 85104

gasket 76 651

43
gypsum board
flange 76 674
soft insulation 50 mm

5.37
connection between curtain wall and partition wall

12.5
E 85

E85CP5.37
01.2011
scale 1:2
50 255 50
1 1 tapping screw 1 1
15 10 10 15 DIN 7981 ST5.5x45-C-H 15 10 10 15
cover cap E 85713
thermal insulation spacer 80 177
delatation
pressure plate E 85700
sheet aluminium 2 mm

E 85 technical catalogue
butyl seal 133 553 membrane 2 mm
gasket 130 500 insulation soft

2
2
24
curtain wall system

10
transom E 85305 gasket 130 470
thermal insulation spacer 80 172

gasket 76 651

flange 76 674

mullion E 85104

130

208

5.38
bracket 71090
40
E 85

E85CP5.38
curtain wall system E 85
connection with backing wall

concrete wall
membrane 2 mm
hard insulation 50 mm
plaster
seal 2 mm
etalbond
butyl seal 133 553

15

20
6 5
1
4

28
16
17

6
10

10
gasket 130 470

thermal insulation spacer 80 172

89
additional profile E 85620

130
41

E85CP5.39

scale 3/4

E 85 technical catalogue
01.2011 5.39
curtain wall system E 85
connection with rainscreen cladding system BRAVO

50

butyl seal 133 553

thermal insulation spacer 80 177


etalbond
29

28
gasket 130 470

membrane 1 mm

bravo system by ETEM


206
177

gypsum board
E85CP5.40

scale 3/4

E 85 technical catalogue
01.2011 5.40
curtain wall system E 85
connection with rainscreen cladding system Forte

8 50
stone

25
30

5
28
34

10
forte system by ETEM
43

metal aluminum sheet

49
hard insulation

membrane

soft insulation
51

additional profile E 85611


41

suppl. profile E 85610


E85CP5.41

scale 3/4

E 85 technical catalogue
01.2011 5.41
curtain wall system E 85
conservatories vertical section with 2nd level transom

135°

cover cap E 85730

thermal insulation spacer 80 174
20

tapping screw
DIN 7981 ST5.5x38-C-H
5

pressure plate E 85701
6
14

butyl seal 133 553


8.4

etalbond
7

hard insulation 17 mm
membrane 1 mm
29

gasket 130 457
glazing shim 71 184
110

transom E 85320
gasket 130 199
32
135°

tapping screw
32

DIN 7981 ST5.5x38-C-H

thermal insulation spacer 80 174

accessory 74 674

gasket 130 457
machine cutting
for transom slot
E85CP5.42

scale 3/4

E 85 technical catalogue
01.2011 5.42
curtain wall system E 85
conservatories vertical section with 3rd level transom

90°-150°

20

5
cover cap E 85730

28
.4
thermal insulation spacer 80 174

14
tapping screw

8.4
DIN 7981 ST5.5x38-C-H

3
pressure plate E 85701
butyl seal 133 553

55
etalbond
hard insulation 30 mm gasket 130 473
membrane 1 mm transom E 85370
suppl. profile E 85670

glazing shim 71 185


90°
30°-

tapping screw
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
gasket 130 473

accessory 74 674
E85CP5.43

20 5 28 9

scale 3/4

E 85 technical catalogue
01.2011 5.43
curtain wall system E 85
conservatories vertical section

90°-150°

pressure plate E 85701

20
cover cap E 85730

5
self-drilling screw

6
DIN 7981 ST4.8x19-M-Z

28 . 4
14
2
113.

8.4
7
thermal insulation spacer 80 174
20

gasket 130 457

glazing shim 71 180


5 4

tapping screw
DIN 7981 ST5.5x38-C-H

89
mullion is trimmed
44

etalbond .7
100
hard insulation 26 mm
113.2

41
membrane 1 mm
etalbond
cut for membrane in mullion
thermal insulation spacer 80 184
F profile 31064
67.4

tapping screw
DIN 7981 ST4.2x25-C-H
5

tapping screw
DIN 7981 ST5.5x38-C-H

thermal insulation spacer 80 174

gasket 130 457

20 5 6 16 6 7 89 41

25 28 7 130
E85CP5.44

not to scale

E 85 technical catalogue
01.2011 5.44
curtain wall system E 85
conservatories vertical section

115 °

pressure plate E 85701

20
cover cap E 85730

5
6
13 1

14
117.2

8.4
7
thermal insulation spacer 80 174
tapping screw
13.9 DIN 7981 ST5.5x38-C-H
gasket 130 457
glazing shim 71 184

mullion connector E 85969 below


seal 10 mm

89
10

14.4

10

seal 10 mm

41
96.8

82.4

20 5 6 16 6 7 89 41
°
115
15
10
50
10

glazing shim 71 184


5

tapping screw
15

DIN 7981 ST5.5x38-C-H

thermal insulation spacer 80 174

gasket 130 457

20 5 6 16 6 7 89 41

25 28 7 130

note:
the glass thickness should be
E85CP5.45

checked by the facade engineer

scale 3/4

E 85 technical catalogue
01.2011 5.45
curtain wall system E 85
conservatories vertical section

20
5
tapping screw

6
DIN 7981 ST4.2x32-C-H

14
8.4
soft insulation 40 mm

6.7
.8
166

47.7

89
10

seal 10 mm

silicone coating
etalbond
96.4

°
115

note: 20 5 6 16 6 7 89 41
the glass thickness
E85CP5.46

should be checked by the


facade engineer
scale 3/4

E 85 technical catalogue
01.2011 5.46
curtain wall system E 85
slope > 25°

tapping screw
DIN 7981 ST5.5x45-C-H
butyl seal 133 553

cover cap E 85730

pressure plate E 85701
gasket 130 500
8
12

>25°
20
5
6
14
0.35
28.3

4 4
5

10

gasket 130 470


thermal insulation spacer 80 172
89

glazing shim 71 183


transom E 85304
mullion E 85104
E85CP5.47

scale 3/4

E 85 technical catalogue
01.2011 5.47
curtain wall system E 85
slope > 15°

pressure plate E 85702


tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 126
silicone gasket 130 705
18
20

2
6
5 6

>15°
14
0.35
28.35

4 4
10

gasket 130 470


thermal insulation spacer 80 171
glazing shim 71 184
transom E 85304
89

mullion E 85104
E85CP5.48

scale 3/4

E 85 technical catalogue
01.2011 5.48
curtain wall system E 85
slope > 7°

flat bar 9070 / 50x2 mm


tapping screw
DIN 7981 ST5.5x45-C-H
silicone gasket 130 705
butyl seal 133 553
22
20

2
5 6

1.2
14 4 4
28.35
0.35

>7°
10

gasket 130 470


thermal insulation spacer 80 171
glazing shim 71 184
transom E 85304
89

mullion E 85104
E85CP5.49

scale 3/4

E 85 technical catalogue
01.2011 5.49
curtain wall system E 85
connection with backing wall

1.5 1
aluminium sheet 1.5 mm 61.5
seal 5 mm

hard insulation 50 mm
aluminium sheet 1.5 mm

4.5

5
membrane 1 mm

46.5

10
10

hard insulation 25 mm
membrane 1 mm

hard insulation 31.5 mm

self-drilling screw
DIN 7981 ST4.2x16-O-Z
1.5
25

131.5

1
1.5

89

bracket E 85913
reinforced concrete
E85CP5.50
41

40
not to scale

E 85 technical catalogue
01.2011 5.50
curtain wall system E 85
bottom finishing

water drainage

gasket 130 500
thermal insulation spacer 80 177
additional profile E 85612 24 38

cut for membrane in mullion


etalbond
27 4
hard insulation 60 mm

bracket 71 050

membrane
hard insulation
30

plaster

hard insulation 50 mm
E85CP5.51

scale 3/4

E 85 technical catalogue
01.2011 5.51
curtain wall system E 85
bottom finishing

20 5 28 10 109 21
water drainage

vapor barrier

membrane

aluninium sheet

thermal insulation spacer 80 177


tile
hard insulation
additional profile E 85612
cut for membrane in mullion
membrane

ground tiles
E85CP5.52

scale 1:2

E 85 technical catalogue
01.2011 5.52
curtain wall system E 85
finishing to suspended ceiling

water drainage
28
20 5 6 16 6 10
mullion E 85104
transom E 85306
gasket 130 470

glazing shim 71 183


butyl seal 133 553

sheet steel 1.5 mm

tapping screw
DIN 7981 ST5.5x45-C-H

thermal insulation spacer 80 172
thermal insulation spacer 80 177
additional profile E 85612
cut for membrane in mullion

etalbond washer DIN 440


bracket 71 270

membrane
concrete slab

hard insulation 60 mm

tube
aluminum 60x30x2
perforation
self-drilling screw
DIN 7981 ST5.5x19-M-Z

vivo system by ETEM


E85CP5.53

not to scale

E 85 technical catalogue
01.2011 5.53
curtain wall system E 85
finishing of plaster ceiling

L-profile section 4065

self-drilling screw
DIN 7981 ST4.8x19-M-Z

30
90

60
etalbond
membrane
membrane additional profile E 85612
hard insulation 32 mm thermal insulation spacer 80 177

4 24 10 33 76
50

bracket 71 050

transom E 85305

20 5 6 16 6 10 mullion E 85104
25 28 10 gasket 130 470

thermal insulation spacer 80 172
E85CP5.54

scale 3/4

E 85 technical catalogue
01.2011 5.54
curtain wall system E 85
outer angle vertical section

25 28 7 130

20 5 6 16 6 7 89 41
gasket 130 457

thermal insulation spacer 80 174
tapping screw
DIN 7981 ST5.5x45-C-H
15
10
50
10
15

thermal insulation spacer 80 177


28

20 5 4 20 4 96
hard insulation 20 mm

etalbond

mullion E 85104

mullion connector E 85960 below


15
10
50
10
15

E85CP5.55

not to scale

E 85 technical catalogue
01.2011 5.55
curtain wall system E 85
inner angle vertical section

41
130

41
89
7
7
6
28

89
16

5
6
25

7
6

15
16

10
10
6

50
5

15
20

86.
6

86.
6

mullion E 85104
86.6

86.6

mullion connector E 85960 below


20 5 6 16 6 7 89
15
10
50
10

tapping screw
15

DIN 7981 ST5.5x45-C-H

thermal insulation spacer 80 174

gasket 130 457

20 5 6 16 6 7 89 41
E85CP5.56

25 28 7 130

not to scale

E 85 technical catalogue
01.2011 5.56
01.2011
scale 1:2

E 85 technical catalogue
profile E 8656
curtain wall system

profile E 8863
glass spandrel panel in brustung zone

3M tape

thermal insulation spacer 80 177


transom E 85380

5.57
sheet steel 2 mm

laminated glass 4.4.1

soft insulation

bracket 71 072

washer DIN 440

steel sheet 2 mm

fire resistant silicone (1250°C)

perforation

0.38
25 min 30
4 4
mullion E 85104

transom E 85305

glazing shim 71 183


butyl seal 133 553

tapping screw
DIN 7981 ST5.5x45-C-H

gasket 130 500

thermal insulation spacer 80 172
E85

E85CP5.57
01.2011
scale 1:2

E 85 technical catalogue
20 5 28 10 109 21
curtain wall system

thermal insulation spacer 80 172

gasket 130 500

butyl seal 133 553

50
tapping screw
DIN 7981 ST5.5x45-C-H

15
aluminum sheet 1 mm

membrane
ceramic tiles in brustung zone rainscreen cladding system VARIO

soft insulation

ceramic tile
Agrob Buchtal

adaptor

vario system by ETEM

mullion E 85104
5.58

transom E 85305

membrane
15

butyl seal 133 553


50

tapping screw
DIN 7981 ST5.5x45-C-H

gasket 130 500

thermal insulation spacer 80 172
E85

E85CP5.58
01.2011
scale 1:2

E 85 technical catalogue
curtain wall system

transom E 85305
gasket 130 470
etalbond spandrel panel in brustung zone

glazing shim 71 183


gasket 130 500
membrane

5.59
butyl seal 133 553
gasket 130 480

min 5
tapping screw
DIN 7981 ST5.5x45-C-H

thermal insulation spacer 80 172

thermal insulation spacer 80 177 2 2
20 123
4 2
151

aluminium sheet 2 mm
etalbond
steel sheet 2 mm

soft insulation

130

bracket 71 072

washer DIN 440

steel sheet 2 mm

fire resistant silicone (1250°C)

mullion E 85104

transom E 85305

thermal insulation spacer 80 177

gasket 130 500
gasket 130 480

butyl seal 133 553


membrane
tapping screw
DIN 7981 ST5.5x45-C-H

thermal insulation spacer 80 172

gasket 130 470


E85

E85CP5.59
01.2011
scale 1:2

E 85 technical catalogue
curtain wall system

soft insulation
connection with rainscreen system Forte

forte system by ETEM

hard insulation

membrane
thermal insulation spacer 80 184

8
thermal insulation spacer 80 174

pressure plate E 85700

50
cover cap E 85720 transom E 85304
bracket 71 050

gasket 130 470


25 5 28 10 89

gasket 130 470

50 glazing shim 71 184

transom E 85300

25 5 28 10 15

glazing shim 71 184


thermal insulation spacer 80 174

pressure plate E 85700 gasket 130 470 transom E 85304


50

cover cap E 85720

bracket 71 050
membrane
47

additional profile E 85611

metal aluminum sheet

bracket E 85967

forte system by ETEM


5.60

membrane
E85

E85CP5.60
curtain wall system E 85
usage of hidden transom on floor level

gasket 130 474

transom E 85380

self-drilling screw
DIN 7981 ST4.8x19-M-Z

steel sheet 2 mm

waterproof
gypsum board
washer DIN 440

bracket 71 072

steel sheet 2 mm

fire resistant silicone (1250°C)


soft insulation

25 28
2
20 5 6 16 6 10 min 30 12.5 50 21

mullion E 85104

transom E 85305
gasket 130 470
glazing shim 71 183
butyl seal 133 553

tapping screw
DIN 7981 ST5.5x45-C-H

gasket 130 500

thermal insulation spacer 80 172
E85CP5.61

not to scale

E 85 technical catalogue
01.2011 5.61
curtain wall system E 85
upper finishing with etalbond 10

min 6
1
4.23

1
4.23

etalbond
membrane

thermal insulation spacer 80 177

thermal insulation spacer 80 172

soft insulation

gypsum board

min 30

bracket 71 270

gasket 130 470


glazing shim 71 183 mullion E 85104

transom E 85305
thermal insulation spacer 80 172
E85CP5.62

tapping screw
DIN 7981 ST5.5x45-C-H

not to scale

E 85 technical catalogue
01.2011 5.62
STRUCTURAL
GLAZING
SECTIONS DETAILS
curtain wall system E 85
mullion with 2nd level transom

silicone seal
silicone gasket 130 705

tapping screw
DIN 7982 ST5.5x25-C-H
15 20 15
10 10 glazing clip 71 116
spacer E 85990
6
32

20
6
6

gasket 130 463


15

gasket 76 651

flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89

3 3
15 10 10 15
130

18 20 18
fixing part 71 113

transom E 85304
6
mullion E 85104
41

50
E85SG6.1

scale 3/4

E 85 technical catalogue
01.2011 6.1
curtain wall system E 85
transom 2nd level drainage

spacer E 85990
glazing clip 71 116
gasket 130 463
flange 76 674 mullion E 85104
glazing shim 71 184
15
10

56.3
20

50
10

tapping screw
5

DIN 7982 ST5.5x25-C-H
15

fixing part 71 113
transom E 85304
gasket 076 651 behind

thermal insulation spaser


80 171/80 183
silicone gasket 130 705
silicone seal

6 20 6 6 89 41

32 6 130

note:
E85SG6.2

spacer E 85990 has to be used only with 2nd level transoms


scale 3/4

E 85 technical catalogue
01.2011 6.2
curtain wall system E 85
mullion with 2nd level transom

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
15 20 15 DIN 7982 ST5.5x25-C-H
10 10 glazing clip 71 130
spacer 33 879
min 6

3M tape
6

min 6
28

16
6
12

12

15 gasket 130 480


gasket 76 651

flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89

3 3
15 10 10 15
130

18 20 18
fixing part 71 113

transom E 85304
6
mullion E 85104
41

50
E85SG6.3

scale 3/4

E 85 technical catalogue
01.2011 6.3
curtain wall system E 85
transom 2nd level drainage

spacer 33 879
glazing clip 71 130
gasket 130 480
flange 76 674
glazing shim 71 184
15

thermal insulation spaser


80 171/80 183
10

56.3
20

50
10

tapping screw
5

DIN 7981 ST5.5x25-C-H
15

min 6

fixing part 71 113
transom E 85304
gasket 076 651 behind

silicone gasket 130 705


silicone seal
mullion E 85104

6 16 6 12 89 41

28 12 130
E85SG6.4

scale 3/4

E 85 technical catalogue
01.2011 6.4
curtain wall system E 85
transom 3rd level drainage

spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185
flange 76 664
15

thermal insulation spaser


80 171/80 183
10

56.3
20

50
10

tapping screw
5

DIN 7981 ST5.5x25-C-H
15

min 6

fixing part 71 113
transom E 85354

6 6 silicone flange 76 680 behind


silicone gasket 130 705
silicone seal
mullion E 85104

6 16 6 12 89 41

28 12 130
E85SG6.5

scale 3/4

E 85 technical catalogue
01.2011 6.5
curtain wall system E 85
projected thermo-break window

thermal insulation spacer silicone seal


80 171/80 183
glass support E 85614 silicone gasket 130 705

gasket 130 707 tapping screw


33.3 DIN 7981 ST5.5x25-C-H
gasket 130 479
1 2 1.6 glazing clip 71 130
structural seal 6 mm 55.5 7.9 20.8
norton tape 6x6.4 mm spacer 33 879 + 3M tape
6

6
6
28
16

16
6
6
7

9.2

gasket 130 176


sash E 85210 gasket 130 480
spacer 700R
gasket 130 461
friction arm 400R/600R
56

operating rod E 2308


striker 255 602 6
striker 255 603

gasket 130 180


frame E 85410 2 3
20 8 38.5 14 11 10 15
38.2

16 21 18
transom E 85304
77

mullion E 85104
41

50
E85SG6.6

scale 3/4

E 85 technical catalogue
01.2011 6.6
curtain wall system E 85
projected thermo-break window with 2nd level transom

6 16 6 7 56 38.2

gasket 130 176


6 6 16
sash E 85210
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 479 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5

38.5
frame E 85410
gasket 130 707
transom E 85304
1

16
14
2
7.9

9.2
33.3

6
1.6
20.8

50

glazing shim 71 182


5
15

min 6

fixing part 71 113
transom E 85304
gasket 076 651 behind
gasket 130 480
silicone gasket 130 705
silicone seal
mullion E 85104

89 41

130
E85SG6.7

scale 3/4

E 85 technical catalogue
01.2011 6.7
curtain wall system E 85
projected thermo-break window with 3rd level transom

6 16 6 7 56 38.2

gasket 130 176


6 6 16
sash E 85210
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 473 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5

38.5
frame E 85410
gasket 130 707
transom E 85354
1

16
14
2
7.9

3
33.3

6
1.6
20.8

50

glazing shim 71 180


5
15

min 6

flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
silicone gasket 130 705
silicone seal
mullion E 85104

6 16 6 6 6 89 41

28 12 130
E85SG6.8

scale 3/4

E 85 technical catalogue
01.2011 6.8
curtain wall system E 85
parallel opening thermo-break window

silicone seal
silicone gasket 130 705
glass support E 85614
80 171 / 80183
gasket 130 707 tapping screw
33.3 DIN 7981 ST5.5x25-C-H
gasket 130 479
1 2 1.6 glazing clip 71 130
structural seal 6 mm 55.5 7.9 20.8
norton tape 6x6.4 mm spacer 33 879 + 3M tape
6

6
6
28
16

16
6
6
7

9.2

gasket 130 176 / P6


sash E 85211 gasket 130 480

gasket 130 461


friction arm 900R/900L
56

operating rod E 2308


6

gasket 130 180


frame E 85410 2 3
20 8 38.5 14 11 10 15
38.2

gasket 130 413


16 21 18
transom E 85304
79.2

mullion E 85104
41

E85SG6.9

50

scale 3/4

E 85 technical catalogue
01.2011 6.9
curtain wall system E 85
parallel opening thermo-break window with 2nd level transom

6 16 6 7 56 38.2

gasket 130 176 / P6


6 6 16
sash E 85211
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 479 gasket 130 180
friction arm 900R/900L
glass support E 85614
55.5

38.5
frame E 85410
gasket 130 707
transom E 85304
2

16
14
7.9

9.2
33.3

6
20.8

50

glazing shim 71 182


5

80 171 / 80183
15

min 6

fixing part 71 113
flange 76 674
gasket 076 651 behind
gasket 130 480

silicone gasket 130 705


silicone seal
mullion E 85104

89 41

130
E85SG6.10

scale 3/4

E 85 technical catalogue
01.2011 6.10
curtain wall system E 85
parallel opening thermo-break window with 3rd level transom

6 16 6 7 56 38.2

gasket 130 176 / P6


6 6 16
sash E 85211
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 473 gasket 130 180
friction arm 900R/900L
glass support E 85614
55.5

38.5
frame E 85410
gasket 130 707
transom E 85354
1

16
14
2
7.9

3
33.3

6
1.6
20.8

glazing shim 71 180 50


5

80 171 / 80183
15

min 6

flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
glazing clip 71 130
silicone gasket 130 705
silicone seal
mullion E 85104

6 16 6 6 6 89 41

28 12 130
E85SG6.11

scale 3/4

E 85 technical catalogue
01.2011 6.11
curtain wall system E 85
window in curtain wall

116 36
41.5 5 69.5
gasket 130 480
additional profile E 85641 silicone gasket 130 705
gasket 130 152 thermal insulation spaser
21 15
80 171/80 183

min 6 mm *
gasket 130 161 11 10 glazing clip 71 130
gasket 130 411
6 spacer 33 879

6
8
6

28
16
11.7
28
16

6
6

12

12
12
9

15
30.5

gasket 130 413


2
89

gasket 130 177

glazing bead 5380


130

sash E 2482
gasket 130 131
frame E 2424

6
transom E 85304
mullion E 85104
41

50
E85SG6.12

* according to ETAG 002

scale 3/4

E 85 technical catalogue
01.2011 6.12
curtain wall system E 85
window in curtain wall

28

8 6 16 6 9 30.5
gasket 130 177
gasket 130 411 glazing bead 5380

21
42.5

gasket 130 152


5

53.5

103
gasket 130 161

sash E 2482
69.5
117

gasket 130 131


additional profile E 85641
frame E 2424
26.5

gasket 130 480


2

min 6 mm *
glazing shim 71 184
6
11
21

50
10

5
15

min 6

silicone gasket 130 705

thermal insulation spaser transom E 85304


80 171/80 183
mullion E 85104
spacer 33 879
glazing clip 71 130
6 16 6 12 89 41
E85SG6.13

* according to ETAG 002 28 12 130

scale 3/4

E 85 technical catalogue
01.2011 6.13
curtain wall system E 85
window in curtain wall

28

8 6 16 6 9 30.5
gasket 130 177
gasket 130 411 glazing bead 5380

21
42.5

gasket 130 152


5

53.5

103

gasket 130 161

sash E 2482
69.5
117

gasket 130 131


additional profile E 85640
frame E 2424
26.5

gasket 130 480


2

glazing shim 71 185


6
11
21

50
10

11.7 6
15

transom E 85354
gasket 130 463
mullion E 85104

6 16 6 6 6 89 41
E85SG6.14

28 12 130

scale 3/4

E 85 technical catalogue
01.2011 6.14
curtain wall system E 85
outer corner 90°
90º

silicone seal
silicone gasket 130 705
tapping screw
DIN 7981 ST5.5x25-C-H etalbond
glazing clip 71 130 hard insulatin

spacer 33 879 + 3M tape 20 41

gasket 130 480

41
suppl. mullion profile E 85143

spacer E 85655

20
tapping screw
DIN 7981 ST5.5x45-C-H

transom E 85354

89 12 6 16 6
101 28
E85SG6.15

scale 3/4

E 85 technical catalogue
01.2011 6.15
curtain wall system E 85
outer corner 90° 90°

etalbond
4 hard insulation 20 mm

seal 4 mm
self-drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.93

silicone seal
silicone gasket 130 705
tapping screw
DIN 7981 ST5.5x25-C-H
glazing clip 71 130 thermal insulation spacer 80 177
spacer 33 879 + 3M tape hard insulation 20 mm
etalbond
4
6

20
16
6

4
12

gasket 130 457

hard insulation 40 mm
89

1
4.93
self drilling screw
DIN 7981 ST4.8x19-M-Z
142
220

L-profile section 4065
blind rivet
DIN 7337 A4.8x8-A
41
50

E85SG6.16

not to scale

E 85 technical catalogue
01.2011 6.16
curtain wall system E 85
inner corner 90°

90°

aluminium tube 7027


silicone seal
silicone gasket 130 705

thermal insulation spacer


80 171/80 183
tapping screw
DIN 7981 ST5.5x25-C-H

glazing clip 71 130


spacer 33 879
3M tape

50
6

3
28
16

25.2
12 6
12

etalbond
gasket 130 480
25.2 130
114
111
89

welded seam 3 mm
130

130

50 111
3
41

114
transom E 85304

flange 76 674

mullion E 85104
E85SG6.17

scale 1:2

E 85 technical catalogue
01.2011 6.17
curtain wall system E 85
inner corner 90°

90°

silicone seal
silicone gasket 130 705
thermal insulation spacer
80 171/80 183
glazing clip 71 130

spacer 33 879 + 3M
12
6
28

16
6
8

15 130
14

145
suppl. mullion profile E 85142

tapping screw
DIN 7981 ST5.5x16-C-H

gasket 130 458

spacer E 85640
89
130

41

E85SG6.18

scale 3/4

E 85 technical catalogue
01.2011 6.18
curtain wall system E 85
silicone seal
polygonal facade with outer angle max 5°
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
20 DIN 7981 ST5.5x25-C-H
glazing clip 71 130

6 16
28
6 5

gasket 130 480


40
35

flange 76 661

3 15 10 10 15 3 transom E 85351
mullion E 85101

silicone seal
silicone gasket 130 705
thermal insulation spaser
polygonal facade with inner angle max 5° 80 171/80 183
tapping screw
19.9 DIN 7981 ST5.5x25-C-H
6

glazing clip 71 130


28
6
616
41

gasket 130 480


35

flange 76 661

transom E 85351
3 15 10 10 15 3
mullion E 85101
E85SG6.19

scale 3/4

E 85 technical catalogue
01.2011 6.19
curtain wall system E 85
conservatories vertical section

90°-150°

gasket 130 480

6
20

30.4
self-drilling screw

16
DIN 7981 ST4.8x19-M-Z

8.4
10
131

gasket 130 470


4

glazing shim 71 184


36

89
27

mullion is trimmed
4 4

etalbond 104
hard insulation

41
membrane 1 mm
etalbond
cut for membrane in mullion
thermal insulation spacer 80 184
4 28 43 F profile 31064
1

gasket 130 473


131

tapping screw
66

DIN 7981 ST4.2x25-C-H
5
20

silicone seal
silicone gasket 130 705

glazing clip 71 130


spacer 33 879
gasket 130 480

6 16 6 12 89 41

28 12 130
E85SG6.20

not to scale

E 85 technical catalogue
01.2011 6.20
curtain wall system E 85
conservatories vertical section

115 °

6
20

30.4
16
8.4
10
120
184
gasket 130 470

glazing shim 71 184

seal 10 mm

89
64 mullion connector E 85969 below
10
16

10

seal 10 mm
48

41
115
99

°
115
20

glazing shim 71 184


silicone seal
silicone gasket 130 705

glazing clip 71 130


spacer 33 879
gasket 130 480

6 16 6 12 89 41

28 12 130

note:
the glass thickness should be
E85SG6.21

checked by the facade engineer

not to scale

E 85 technical catalogue
01.2011 6.21
curtain wall system E 85
connection with rainscreen cladding system BRAVO

100 20
etalbond
29

bravo system by ETEM


207
178

gypsum board
E85SG6.22

scale 3/4

E 85 technical catalogue
01.2011 6.22
curtain wall system E 85
connection with backing wall

etalbond
bravo system by ETEM

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
DIN 7981 ST5.5x25-C-H
glazing clip 71 130
122 20 spacer 33 879
3M tape

28
16
6
membrane 1 mm

12

12
gasket 130 480

additional profile E 85612

89

130
41

E85SG6.23

scale 3/4

E 85 technical catalogue
01.2011 6.23
curtain wall system E 85
bottom finishing

gasket 130 480

glazing clip 71 130


thermal insulation spacer
80 171/80 183
silicone seal
20

silicone gasket 130 705

thermal insulation spacer 80 177

additional profile E 85612


24 38
cut for membrane in mullion

etalbond
bracket 71 050
concrete slab

27
30

soft insulation 60 mm
membrane
L-profile section 4065
self-drilling screw
DIN 7981 ST4.8x19-M-Z

seal 6 mm
plaster

perforation

hard insulation
E85SG6.24

scale 1:2

E 85 technical catalogue
01.2011 6.24
curtain wall system E 85
facade finishing to suspended ceiling

28 12 130
6 16 6 12 109 21
spacer 33 879
glazing clip 71 130
gasket 130 480
flange 76 651
glazing shim 71 182
steel sheet 1.5 mm
15
20
15

thermal insulation spacer 80 177


additional profile E 85612
cut for membrane in mullion

accessory 74 674

bracket 71 270 washer DIN 440

hard insulation

membrane

concrete slab

etalbond

self-drilling screw
DIN 7981 ST4.8x19-M-Z
perforation
L-profile section aluminum
E85SG6.25

not to scale

E 85 technical catalogue
01.2011 6.25
curtain wall system E 85
finishing of plaster ceiling

L-profile section 4065

self-drilling screw
DIN 7981 ST4.8x19-M-Z

30
60
etalbond
membrane
membrane additional profile E 85612
hard insulation thermal insulation spacer 80 177
15

33 76
20

bracket 71 050
15

transom E 85305

mullion E 85104
gasket 130 480

6 16 6 12 109 21
28 12 130
E85SG6.26

170
scale 3/4

E 85 technical catalogue
01.2011 6.26
curtain wall system E 85
etalbond spandrel panel in brustung zone
170

28 12 130
6 16 6 12 109 21

spacer 33 879

glazing clip 71 130

gasket 130 480

flange 76 651
glazing shim 71 182
transom E 85305
steel sheet 2 mm
self-drilling screw
DIN 7981 ST4.8x16-M-Z

self-drilling screw
DIN 7981 ST4.8x19-M-Z

20 60
thermal insulation spacer 80 177 4 4
28 60
88
etalbond

soft insulation

bracket 71 272
washer DIN 440

steel sheet 2 mm

self-drilling screw
DIN 7981 ST4.8x16-M-Z

mullion E 85104

transom E 85305
thermal insulation spacer 80 177
E85SG6.27

not to scale

E 85 technical catalogue
01.2011 6.27
curtain wall system E 85
upper finishing with etalbond 10

1
4.23

1
4.23
110
20

glazing clip 71 130


gasket 130 480

6 16 6 12 109 21 40
28 12 130 40
170

soft insulation

gypsum board
340

min 30

bracket 71 270

washer DIN 440


20

mullion E 85104
E85SG6.28

transom E 85305

not to scale

E 85 technical catalogue
01.2011 6.28
COMBINATIONS

SECTIONS DETAILS
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint

50 tapping screw
DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713

pressure plate E 85700

butyl seal 133 553


20

gasket 130 500
25

6 5

min 6 gasket 130 473


28

16
6
12

12

gasket 130 480

thermal insulation spacer 80 172

gasket 76 651
195.2

flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89

3 3
15 10 10 15
130

18 20 18
fixing part 71 113

transom E 85304
6
mullion E 85104
41

50
E85K7.1

scale 3/4

E 85 technical catalogue
01.2011 7.1
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint

spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185
flange 76 664
15

thermal insulation spaser


80 171/80 183
10

56.3
20

50
min 6
10

tapping screw
5

DIN 7981 ST5.5x25-C-H
15
min 6

fixing part 71 113
transom E 85354

6 6 silicone flange 76 680 behind


silicone gasket 130 705
silicone seal
mullion E 85104

20 5 6 16 6 12 89 41

25 28 12 130
E85K7.2

scale 3/4

E 85 technical catalogue
01.2011 7.2
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
with projected thermo-break window

gasket 130 706 tapping screw


50 DIN 7981 ST5.5x45-C-H
gasket 130 479 9 14.4 14.2 10.8 10 15
33 45.8 cover cap E 85713
glass support E 85615
pressure plate E 85700
gasket 130 131
butyl seal 133 553
structural seal 6 mm
gasket 130 500

25
norton tape 6x6.4 mm
6

6
gasket 130 473
6
28

28
16

16
31
16
6

6
6
7

12
gasket 130 176 / P6
9

sash E 85210 gasket 130 480


spacer 700R
gasket 130 461
friction arm 400R/600R
56

operating rod E 2308


striker 255 602
striker 255 603

gasket 130 180


frame E 85410 2 3
20 8 38.5 15 10 10 15
38.2

18 20 18
transom E 85304
79.2

mullion E 85104
41

50
E85K7.3

scale 3/4

E 85 technical catalogue
01.2011 7.3
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
with 3rd level transom and projected thermo-break window

6 16 6 7 56 38.2

gasket 130 176 / P6


6 6 16
sash E 85210
gasket 130 461
norton tape 6x6.4 mm

20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 473 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5

38.5
frame E 85410
gasket 130 707
transom E 85354
1

16
14
2
7.9

3
33.3

6
1.6
20.8

50

min 6 glazing shim 71 185


5

glazing clip 71 130


thermal insulation spaser
15

80 171/80 183
min 6

flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
silicone gasket 130 705
silicone seal
mullion E 85104

20 5 6 16 6 6 6 89 41

25 28 12 130
E85K7.4

scale 3/4

E 85 technical catalogue
01.2011 7.4
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
15 20 15 DIN 7981 ST5.5x25-C-H
10 10 glazing clip 71 130
spacer 33 879
15
20

min 6
6 5

min 6 tape
28

16
6
12

12

gasket 130 480


gasket 76 651

flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89

3 3
15 10 10 15
130

18 20 18
fixing part 71 113

transom E 85304
6
mullion E 85104
41

50
E85K7.5

scale 3/4

E 85 technical catalogue
01.2011 7.5
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap

cover cap E 85712


pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 463
glazing shim 71 185
15
10

56.3
50

50
10

5
15

flange 76 664
fixing part 71 113
transom E 85354
silicone flange 76 680 behind
thermal insulation spacer 80 172

PVC spacer 9020

mullion E 85104
20 28 6 6 89 41

6 16 6 12 130
E85K7.6

scale 3/4

E 85 technical catalogue
01.2011 7.6
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
with parallel opening thermo-break window

silicone seal

glass support E 85614 33.3 silicone gasket 130 705


tapping screw
gasket 130 707 55.5 20.8 DIN 7981 ST5.5x25-C-H
gasket 130 479 glazing clip 71 130
structural seal 6 mm
spacer 33 879
15

norton tape 6x6.4 mm


20

min 6
6 5

6
6
28
16

16
6
6
7

9.2

gasket 130 176


sash E 85211 gasket 130 480

gasket 130 461


friction arm 900R/900L
56

operating rod E 2308


6

gasket 130 180


frame E 85410 2 3
20 8 38.5 14 11 10 15
38.2

16 21 18
transom E 85304
79.2
41

mullion E 85104

50
E85K7.7

scale 3/4

E 85 technical catalogue
01.2011 7.7
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
with 3rd level transom and parallel opening thermo-break window

gasket 130 176


sash E 85211

20
gasket 130 461
norton tape 6x6.4 mm
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z

8
gasket 130 131 gasket 130 180
33

friction arm 900R/900L


gasket 130 706

38.5
frame E 85410
9

transom E 85304
14.4

2
45.8

36
gasket 130 473
50

31
gasket 130 473 3

glazing shim 71 185


gasket 130 463

gasket 130 500 thermal insulation spacer 80 172

20 6 16 6 12 89 41
E85K7.8

scale 3/4

E 85 technical catalogue
01.2011 7.8
curtain wall system E 85
anti-burglar system
mullion with 2nd level transom

143 906
143 907
cover cap E 8700
60
50 009
pressure plate E 8620

butyl seal 133 553


25
61

gasket 130 500
10

B2310 (P5A)
5
23

thermal insulation spacer 80 171


8

gasket 130 458


gasket 76 651

tube 47 001
143 905

71 221
89

71 218
130
191

71 228

flange 76 674

transom E 85304

mullion E 85104
41

50
E85K7.9

scale 3/4

E 85 technical catalogue
01.2011 7.9
curtain wall system E 85
anti-burglar system
transom 2nd level drainage

B2310 (P5A)
cover cap E 8701

pressure plate E 8620
gasket 130 500
butyl seal 133 553
thermal insulation spacer 80 171
gasket 130 458
flange 76 674

71 221

56.3
60

50
143 906
143 907 71 218

glazing shim 71 182


10
transom E 85304
gasket 076 651 behind
50 009
mullion E 85104

23 5 23 8 89 41
2
61 130
191
E85K7.10

scale 3/4

E 85 technical catalogue
01.2011 7.10
MACHININGS

MACHINING PROCESSING
curtain wall system E 85
cutting lengths

transom
pressure plate
cover cap

E85M8.1

not to scale

E 85 technical catalogue
01.2011 8.1
curtain wall system E 85
machinings of transom 2nd level drainage with spring t-joint and flange

mullion

A
flange
∅12

fixing part 71 113

transom

18

15

gasket 76 651

DIN 7981 ST4.8x19-C-H

additional machining of transom for the spring t-joint


transom flange A mm
E 85301 76 671 --
E 85302 76 672 --
E 85303 76 673 --
E 85304 76 674 78,5
E 85305 76 675 98,5
E 85306 76 676 118,5
E85M8.2

E 85307 76 677 148,5

not to scale

E 85 technical catalogue
01.2011 8.2
curtain wall system E 85
machinings of transom 3rd level drainage with spring t-joint and flange

mullion

A flange
∅12

fixing part 71 113

transom
18

silicone flange 76 680

tapping screw
DIN 7981 ST4.8x19-C-H

transom flange A mm
E 85360 76 660 -- additional machining of transom for the spring t-joint
E 85351 76 661 --
E 85352 76 662 --
E 85353 76 663 58,5
E 85354 76 664 78,5
E 85355 76 665 98,5
E 85356 76 666 118,5
E 85357 76 667 148,5
E 85358 76 668 168,5
E85M8.3

E 85359 76 669 188,5

not to scale

E 85 technical catalogue
01.2011 8.3
curtain wall system E 85
machinings of transom 2nd level drainage with T-joint and flange

mullion

flange

T-joint

transom
18

15

gasket 76 651

tapping screw
DIN 7981 ST4.8x19-C-H

transom flange T-joint


E 85302 76 672 71 122
E 85303 76 673 71 123
E 85304 76 674 71 124
E 85305 76 675 71 125
E85M8.4

E 85306 76 676 71 126


E 85307 76 677 71 127
not to scale

E 85 technical catalogue
01.2011 8.4
curtain wall system E 85
machinings of transom 2nd level drainage with T-joint and flange

mullion

flange

T-joint

transom
18

silicone flange 76 680

tapping screw
DIN 7981 ST4.8x19-C-H

transom flange T-joint


E 85351 76 661 71 131
E 85352 76 662 71 132
E 85353 76 663 71 133
E 85354 76 664 71 134
E 85355 76 665 71 135
E 85356 76 666 71 136
E 85357 76 667 71 137
E 85358 76 668 71 138
E85M8.5

E 85359 76 669 71 139


E 85369 76 670 71 144
not to scale

E 85 technical catalogue
01.2011 8.5
curtain wall system E 85
machinings of transom 2nd level drainage with transom connectors

7 6.5
15

5
15
mullion 20
46
17 15
8

flange

T-joint

transom
17

15
gasket 76 651

tapping screw
DIN 7981 ST4.8x19-C-H

transom flange T-joint


E 85302 76 622 71 152
E85M8.6

E 85303 76 623 71 153

not to scale

E 85 technical catalogue
01.2011 8.6
curtain wall system E 85
machinings of transom 3rd level drainage with transom connectors

7
6.5
6

5
15
mullion
20
46
17 15
8

flange

T-joint

transom
17

6
silicone flange 76 680

tapping screw
DIN 7981 ST4.8x19-C-H

transom flange T-joint


E 85351 76 624 71 141
E85M8.7

E 85352 76 625 71 142

not to scale

E 85 technical catalogue
01.2011 8.7
curtain wall system E 85
machinings of transom 2nd level drainage with reinforcement
T-joint 71 140
66
22
.5
∅1 0

22.8
87

mullion
4 3

46
∅ 12

19
69
flange 76 676 87
44
∅16
T-joint 71 140

set 71 219

set 71 218

14

∅12
53
gasket 76 651
15.5 18 45
tapping screw
DIN 7981 ST4.8x19-C-H
∅12
reinforcement 85 801 15 53
31

reinforcement 71 187 DIN 7981 5.5x38



∅6
∅6

4 .2 4 .2 transom 85306

reinforcement 71 187
8
20
80
92
100 additional
DIN 7981 4.8x19 reinforcement 71 186 /optional/
9

14 12
74 12
100
note:
E85M8.8

In case of 2nd level transom, glazing shim reinforcement should be placed before connecting transom and mullion.
Additional reinforcement 71 186 has to be used in case of thicker glazings.
not to scale

E 85 technical catalogue
01.2011 8.8
curtain wall system E 85
machinings of transom 3rd level drainage with reinforcement

T-joint 71 143
96
22
∅10.5

22.8
132

4 ∅1 3
mullion 2

14
19
flange 76 677 114
132
74
∅16
T-joint 71 143

set 71 219

set 71 218

14

silicone flange 76 680 ∅12


98
tapping screw 15.5 45
DIN 7981 ST4.8x19-C-H 18

reinforcement E 85802 ∅12


6 98
22
DIN 7981 5.5x38

reinforcement 71 188 ∅6
∅ ∅6
4.2 4.2 transom 85357

reinforcement 71 188
8
20 additional
80 reinforcement 71 186 /optional/
92 DIN 7981 4.8x19
100

additional reinforcement 71 186


∅5 ∅5
9

14 12 8
74 12 92
E85M8.9

100 100
note:
Additional reinforcement 71 186 has to be used in case of thicker glazings.
not to scale

E 85 technical catalogue
01.2011 8.9
curtain wall system E 85
fixing of 3rd level transom using transom connector E 85994 at angle ≥ 90°

mullion

a° = 0° ~ 60°

(D-20) + 50 x sin(a°)
butyl seal X=
76 681 between cos(a°)
mullion and transom

transom connector E 85994

tapping screw
a° DIN 7981 ST4.8x19-C-H

tapping screw b
DIN 7981 ST4.8x19-C-H

tapping screw
DIN 7981 ST4.8x38-C-H

transom

90-a°

transom b, mm
E 85351 25
E 85352 45
E 85353 43
E 85354 63
E 85355 83
E 85356 103
E 85357 133
E 85358 153
E85M8.10

E 85359 173
E 85369 224

not to scale

E 85 technical catalogue
01.2011 8.10
curtain wall system E 85
transom connector E 85994
83.15

68.55

57.2

48.0

40.3

33.6
27.7
22.4
17.5
12.9
8.5
Fixing devices have to 4.2
be placed coaxially Distance between
even though transoms fixing devices must be 0.0
are not parallel. evaluated according to 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60°
the following diagram, a(°)
so that to achieve
smooth transition of a° = 0° ~ 60°
the external webs of
every transom

Capability of fastening
transom by screws on the
frontal face of fixing device

90-a°

In order to achieve optimum result in terms of aesthetics, the


axis of the rotated transom must always be in accordance to
the diagram above,depending on the angle of rotation, so that

the centre of rotation of the transom is at the intersection of
E85M8.11

the axes of rotated and non rotated transoms

not to scale

E 85 technical catalogue
01.2011 8.11
curtain wall system E 85
connection between transom E 85300 and supplementary transom to mullion

supplementary
flange
transom
E 85600 76 650
E 85601 76 652
E 85602 76 653
E 85603 76 654

10
100

supplementary transom

76 650

tapping screw
DIN 7982 ST4.8x19-C-H
E85M8.12

tapping screw
DIN 7981 ST4.8x19-C-H
not to scale

E 85 technical catalogue
01.2011 8.12
01.2011
not to scale
20
B2 20
L1 71 207 20 20 L1 71 065
05 B 2 L 10
5 71 090 B2 B2 05 71 072 58
L1 B1
05
fixing brackets

E 85 technical catalogue
L1
71 270 06

H 120
H 65

H 90
H 72

H 115
52 52 52
52
curtain wall system

52

L1 10 71 565
58 05 71 120 71 290 58 58 71 390
B1 B2
58 L1 B1 B1
B1 05 L1
06 71 015 L1 L1
06 50

H 120
H 65

H 90
H 72

H 115
52 52
51.8 53

8.13
52

20
10 10 71 572 B2 L1 71 265
B2 L1 71 150 71 159 B2 05
50 10 10
B2 B2
L1
50 71 250 L1
L1 50
50

H 120
H 90
H 65

H 72

52

H 115
52 52 53

53

fixed support
movable support
E 85

E85M8.13
curtain wall system E 85
fixing brackets

L1 71 121 71 091
4 05
B8 L1
4 05
B8
H 120

4
L1
05
71 172 H 90 71 372
B8
L1
4 05
B8
H 115

H 72

71 165
4
B8 L1
05
H 65

min
120
fixed support
H

movable support
H/2

E85M8.14

not to scale

E 85 technical catalogue
01.2011 8.14
curtain wall system E 85
anchoring elements for fixing brackets
set for movable support
71 212 - for systems Е85
nut M10
washer 71 208 from profile Е 85901
bush ø15x63
washer 71 208 from profile Е 85901
washer ø10
bolt M10x100

anchor for concrete


movable support (set with washer and nut)
07M12123S

B washer 71 208 from profile Е 85901

anchor for concrete 07M12123S


(set with washer and nut)

anchor М12х123

washer ø12
nut M12

fixed support

washer 71 208 from profile Е 85901


A

set for fixed support


71 211 - for systems Е85
nut M10
washer 71 208 from profile Е 85901
bush ø15x51
washer 71 208 from profile Е 85901
washer ø10
bolt M10x100
E85M8.15

not to scale

E 85 technical catalogue
01.2011 8.15
curtain wall system E 85
simply supported beams
anchor for concrete
(set with washer and nut)
07M12123S

movable
support

bolt M10x100

anchor for concrete


(set with washer and nut)
07M12123S

bush ø15x51

fixed
support

bolt M10x100 bolt M10x100


E85M8.16

not to scale

E 85 technical catalogue
01.2011 8.16
curtain wall system E 85
beam supported at three points
anchor for concrete
(set with washer and nut)
07M12123S

bolt M10x100
movable B
support
anchor for concrete
(set with washer and nut)
07M12123S

A
movable
support

bolt M10x100
anchor for concrete
(set with washer and nut)
07M12123S

bush ø15x51

fixed
support

bolt M10x100 bolt M10x100


E85M8.17

not to scale

E 85 technical catalogue
01.2011 8.17
curtain wall system E 85
fixing brackets

43
.2 71 050 or 43.
E 85913 profile 2

E 85918

H 140
profile
nut М12 washer ø12

H 90
B2
20
B2
10

anchor М12х123

set for bracket as a hidden


DIN 440
support 71 213

anchor M12x123
nut М10
bush ø15x50 / 2pc.

washer ø10
bolt М10x70

min
120

120
H

min
min
min 120
120 120 min
H/2

note:
accessories from profiles E 85913 and E 85918 can be produced and delivered
E85M8.18

with the machinings, after ordering and specifing the mullion.


not to scale

E 85 technical catalogue
01.2011 8.18
curtain wall system E 85
combinations and machinings

30

4 30

movable support
mullion
cut for membrane

insert

30

mullion

fixed support ø4 35

ø11
M10x150
membrane
ø8

bar 50x8 mm
10

20

M8x40
B

∅8 transom insert A, mm B, mm min C, mm min


E 85102 E 85952 96,0 38,4 29,6
E 85103 E 85953 116,0 58,4 29,6
0
C

∅2 E 85104 E 85954 136,0 78,4 29,6


E 85105 E 85955 166,0 108,4 29,6
E 85106 E 85956 183,5 123,9 31,6
18

E 85107 E 85957 203,5 143,9 31,6


bar 50x8 mm E 85108 E 85958 200,5 134,9 37,6
E85M8.19

50

not to scale

E 85 technical catalogue
01.2011 8.19
curtain wall system E 85
connection between two mullions with insert
- The joint of the cover caps must be at least 50 mm lower
than the joint of the pressure plates, which in turn must be 50 tapping screw
mm lower than the joint of the mullions DIN 7981 ST2.9x6.5-C-H

- The screws used for fastening the drainage devices must


not be longer than 8 mm so that dilatation is not impaired. The
drainage devices MUST always be fastened on the upper
mullion and the fixing openings as the contact area only on the

8
upper mullion is sealed with silicone (*).

71 209 (kit)
ST 2,9

Put silicone on
the upper surface

The joint between


mullions is sealed
with silicone

shaped INOX or
aluminium sheet (1mm)

Rectangular standard
profile 40x4 mm
anchored in the middle
of the stiffener by
plastic deformation of
the tracks

ATTENTION:
The cutting length of the
horizontal pressure plate must
not be less than (L-55)

L (Distance between axes)

ST 2,9

ATTENTION:
Do not use a screw with greater size than the recommended, 27.5 L - 55
because it has to be covered by the horizontal cover cap L - 51
E85M8.20

(shortest cover cap E-85711 - 12mm)

not to scale

E 85 technical catalogue
01.2011 8.20
curtain wall system E 85
transom to transom connection

1 1 1 1
2 2 2

2 2 2

2 2
E85M8.21

2 2

not to scale

E 85 technical catalogue
01.2011 8.21
curtain wall system E 85
condensation water drainage
water drainage

*upside down

max 8 m
max 8 m
max 8 m
fill with silicone here

drainage profile 74 674


50
30

drainage profile 74 674


12
E85M8.22

pressure plate

not to scale

E 85 technical catalogue
01.2011 8.22
curtain wall system E 85
bottom finishing

cut for membrane


mullion

mullion
27 4

transom

add. profile E 85612

cut for membrane in mullion

bracket 71 050

concrete slab

membrane
E85M8.23

not to scale

E 85 technical catalogue
01.2011 8.23
curtain wall system E 85
fixing of transom E 85320 part of gasket 76 651

tapping screw
DIN 7981 ST2.9x6.5-C-H

36

tapping screw
DIN 7981 ST4.8x19-C-H

part of gasket 76 651 a°


16

accessory 74 674

transom E 85320

membrane

a° = 30° ~ 83°

aluminium sheet
ATTENTION: gasket 130 199
- drainage fitting from profile E 85 991 has to be cut on angle a° for each project
E85M8.24

- accessory 74 674 must be inserted before assembly of mullions


- accessory 74 674 must be filled with silicone after fixing to mullion
not to scale

E 85 technical catalogue
01.2011 8.24
curtain wall system E 85
fixing of transom E 85370 a°

tapping screw
DIN 7981 ST2.9x6.5-C-H
cut from profile 85 911

transom E 85370

accessory 74 674

suppl. profile E 85670

tapping screw
DIN 7981 ST4.8x19-C-H membrane

silicone flange 76 680

6
16
a° = 0° ~ 83°

ATTENTION:
- drainage fitting from profile E 85 991 has to be cut on angle a° for each project
E85M8.25

- accessory 74 674 must be inserted before assembly of mullions


- accessory 74 674 must be filled with silicone after fixing to mullion
transom E 85370
not to scale

E 85 technical catalogue
01.2011 8.25
curtain wall system E 85
roof connection of two mullions using E 85960 ATTENTION:
Fasteners, washers, spring
washers etc, must be made of
a° stainless steel A2.

X X B = 25mm (min)
C = B - 4,5mm

X
article has to be cut at two B
points at the peak
axis of measuring angles

ø3
M6

M6 Grooves for
X X TIG-MIG
weldment

C
M8

M8 ATTENTION:
Welding is
compulsory
A

note:
The number of sets 71 216 needed has to be
determined by the facade engineer taking into
consideration the applied loads in each specific case.

transom A, mm B, min mm C, min mm


E 85101 38 25 20,5
E 85102 58 25 20,5
E 85103 78 25 20,5
E 85104 98 25 20,5
E85M8.26

E 85105 128 25 20,5

not to scale

E 85 technical catalogue
01.2011 8.26
curtain wall system E 85
roof connection of two mullions using E 85969
ATTENTION:
Fasteners, washers, spring
a° washers etc, must be made of
stainless steel A2.

B = Cmin+X

X thickness of wall

article has to be cut at two


points at the peak
axis of measuring angles

nut M6 spring pin ø5x40

cap head bolt M6x50 grooves for


TIG-MIG
weldment
∅12
∅12
underlay washer ø8

bush M8x50

C ATTENTION:
countersunk bolt M8x25 welding is
compulsory

note:
all fixings are included in set 71 216
for roof connection

transom A, mm B, mm min C, mm min


E85M8.27

E 85109 182 35,5 20,5

not to scale

E 85 technical catalogue
01.2011 8.27
curtain wall system E 85
machinings
14.5

23.8
5

5
∅7
23.8 20 10 15 10 30

6 4 2 2.5 2.5

5.5 5
63 25
5.5 5
ATTENTION:
Apart from the submarginal drainage holes which have to be opened in any case
both on the pressure plate and cover cap, additional holes have to be opened in
the middle, in case that the length of the transom is greater than 1.25 m or if the
surface of the glass pane is greater than 2 m²
25
every 180~240

20 180~240 every 180~240


E85M8.28

not to scale

E 85 technical catalogue
01.2011 8.28
curtain wall system E 85
water drainage with 2nd level transom
B
A

B-B

28 34
thermal insulation spacer 80 172 thermal insulation spacer 80 172

gasket 130 474


water drainage
water drainage

A-A

150

150

butyl seal 133 553

note:
1. In case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone.
E85M8.29

2. In case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is
obligatory to use butyl seal tape in both directions.
not to scale

E 85 technical catalogue
01.2011 8.29
curtain wall system E 85
fixing of E 85723 to E 85745

pressure plate E 85700

pressure plate E 85745

cap E 85713

cap E 85723

tapping screw
DIN 7981 ST3.5x13-C-H

note:
all big cover caps (E 85723, E85724, E85716, E85718) have
E85M8.30

to be used with pressure plate E85745 and to


be fastened with screws

not to scale

E 85 technical catalogue
01.2011 8.30
curtain wall system E 85
assembling of spacer for structural glazing
B-B
positions 1 2 3 4
outside inside
W1
W3 28
250 120 X 120 X 120 250 6 min 16 6

spacer 33 879
71 130 71 130 71 130
min 100

6
24
17
71 130 71 130
X

A A glazing clip 71 130


H3
H1

71 130 71 130
glazing shim 71 185
X

A-A silicone gasket 130 705


thermal insulation spacer 80 171 glazing clip 71 130
71 130 71 130 spacer 33 879
20

B
min 100

71 130 71 130 71 130


28
16
40.2

glazing shim 100 B 100 glazing shim


6

250 120 X 120 X 120 250


W3
12.2

W1

X = 250 ~ 300 mm (depends of


overall dimentions and wind load)

cutting of spacer
width of spacer W1 = W2 – 34
height of spacer H1 = H2 – 34

cutting of spacer 33 879


width of spacer W3 = W1
height of spacer H3 = H1 – 200
235
300
150
100

100

glazing clip 71 130


160
glazing shim

thermal insulation spaser 80 183


E85M8.31

not to scale

E 85 technical catalogue
01.2011 8.31
curtain wall system E 85
structural glazing assembly

mullion

gasket

thermal insulation spacer 80 171

glazing clip 71 130

tapping screw
DIN ISO 7050 ST5.5x22-C-H

thermal insulation spacer 80 183

spacer 33 879
E85M8.32

not to scale

E 85 technical catalogue
01.2011 8.32
curtain wall system E 85
projected window fixings and machinings

29.5 12
E 85410 E 85210

5.6 9.6
20.3

10.5

10.5
13

13
40.1

40.1
19

19
6 6

4.5
20
scale 1:2 scale 1:2
54 302
54 457

54 462

54 302

54 457
E85M8.33

54 462

not to scale

E 85 technical catalogue
01.2011 8.33
curtain wall system E 85
machining of drainage opening

E85M8.34

not to scale

E 85 technical catalogue
01.2011 8.34
curtain wall system E 85
machining of glass support E 85615

glass support E 85615


glass support E 85615
structural glazing silicone
45°

tapping screw
°

DIN 7982 ST3.5x13-C-H
90

45°

note:
glazing support E 85615 is stocked in
E85M8.35

color RAL 9005

glass support E 85615


not to scale

E 85 technical catalogue
01.2011 8.35
curtain wall system E 85
machining of glass support E 85614

glass support E 85614


glass support E 85614
structural glazing silicone
45°

45°
°
90

tapping screw
DIN 7982 ST3.5x13-C-H

glass support E 85614

note:
E85M8.36

glazing support E 85614 is


stocked in color RAL 9005
not to scale

E 85 technical catalogue
01.2011 8.36
curtain wall system E 85
profiles for projected window

glass support E 85615


glass support E 85614

glass support E 85614

structural glazing silicone glass support E 85615

structural glazing silicone

tapping screw
DIN 7982 ST3.5x13-C-H

tapping screw
DIN 7982 ST3.5x13-C-H
E85M8.37

not to scale

E 85 technical catalogue
01.2011 8.37
curtain wall system E 85
required machinings of gaskets 130 706 and 130 707 for
projected window used in two sided curtain wall

E85M8.38

note:
cutting of EPDM 130 706 and 130 707 has to be performed with patterns 990 522 and 130 521

not to scale

E 85 technical catalogue
01.2011 8.38
curtain wall system E 85
projected opening window

800R - set of nuts


for 400R and 600R
blind rivet nut M5 - 14 pcs

screw M5x16 - 6 pcs

countersunk screw M5x20 - 8 pcs

arm for projected window


angle of height of
code type length, mm load, kg
opening, ° frame, mm
E85M8.39

400 R adjustable 405 25 500-1200 80


600 R adjustable 665 15 1201-2000 130

not to scale

E 85 technical catalogue
01.2011 8.39
curtain wall system E 85

E 85 technical catalogue
01.2011 8.40
curtain wall system E 85
etalbond and glass panels

E 40956 (11mm)

etalbond

E-85291

silicone gasket 130 705

E-85290

etalbond

ATTENTION:
E85M8.41

etalbond protection membrane from etalbond


etalbond has to be put before sealing the
not to scale structural joint with silicone.

E 85 technical catalogue
01.2011 8.41
curtain wall system E 85
etalbond panels

L = distance between mullion axes


D = distance between transom axes

L-20
E 40956 (18.2mm)

50

50

etalbond

E 85290

** Groove accepts self


adhesive tape (10mm).

25

L-20*

ATTENTION:
* correction because of cutting dimensions of panel
etalbond cassette making. are for 4mm etalbond.
E85M8.42

not to scale

E 85 technical catalogue
01.2011 8.42
ACCESSORIES

IMAGES DESCRIPTIONS
code/description package/pcs colour mullion

ET071207 1 MF

fixing bracket 120 mm

ET071090 1 MF

fixing bracket 90 mm

ET071120 1 MF

fixing bracket 120 mm

ET071290 1 MF

fixing bracket 90 mm

E 85 technical catalogue
01.2011 9.1
code/description package/pcs colour

ET071150 1 MF

fixing bracket 120 mm

ET071159 1 MF

fixing bracket 90 mm

ET071270 1 MF

fixing bracket 115 mm

ET071072 1 MF

fixing bracket 72 mm

E 85 technical catalogue
01.2011 9.2
code/description package/pcs colour

ET071265 1 MF

fixing bracket 65 mm

ET071015 1 MF

fixing bracket 115 mm

ET071390 1 MF

fixing bracket 72 mm

ET071065 1 MF

fixing bracket 65 mm

E 85 technical catalogue
01.2011 9.3
code/description package/pcs colour

ET071250 1 MF

fixing bracket 115 mm

ET071572 1 MF

fixing bracket 72 mm

ET071565 1 MF

fixing bracket 65 mm

ET071121 1 MF

fixing bracket 120 mm

E 85 technical catalogue
01.2011 9.4
code/description package/pcs colour

ET071091 1 MF

fixing bracket 90 mm

ET071172 1 MF

fixing bracket 115 mm

ET071372 1 MF

fixing bracket 72 mm

ET071165 1 MF

fixing bracket 65 mm

E 85 technical catalogue
01.2011 9.5
code/description package/pcs colour

ET071050 1 MF

hidden fixing bracket 50 mm

ET071211 1 MF

set for bracket as a fixed support

ET071212 1 MF

set for movable support

ET071213 1 MF

set for hidden fixed support

E 85 technical catalogue
01.2011 9.6
code/description package/pcs colour

ET071216 1 MF

set for roof connector

ET071218 1 MF

set for reinforced T-joint

ET071219 1 MF

fixing set transom mullion

ET071208 1 MF

washer

E 85 technical catalogue
01.2011 9.7
code/description package/pcs colour

DIN440 MF

washer

07M12123S 1 MF

galvanized anchor M12x123

DIN 7981 100 MF

tapping screw ST4.8x19-C-H


ST4.8x25-C-H
ST5.5x19-C-H
ST5.5x25-C-H
ST5.5x32-C-H
ST5.5x38-C-H
ST5.5x45-C-H

DIN 7982 100 MF

tapping screw ST3.5x13-C-H


ST4.8x19-C-H
ST5.5x25-C-H

E 85 technical catalogue
01.2011 9.8
code/description package/pcs colour

ET071209 50 MF

drainage fitting between mullions

ET074674 50

drainage for mullion

ET074657 50

plastic plug for profile


E85723

ET076651 50

EPDM flange between


mullion and transom
2nd level drainage

E 85 technical catalogue
01.2011 9.9
code/description package/pcs colour

ET076680 200

seal between mullion


and transom
3rd level drainage

ET076681 6m

butyl seal between mullion


and transom III level drainage

ET071113 100 MF

fixing part between transom


and mullion with spring

ET076671 800

PVC flange for transom

Е-85 301

E 85 technical catalogue
01.2011 9.10
code/description package/pcs colour

ET076672 600

PVC flange for transom

Е-85 302

ET076673 600

PVC flange for transom

Е-85 303

ET076674 400

PVC flange for transom

Е-85 304

ET076675 350

PVC flange for transom

Е-85 305

E 85 technical catalogue
01.2011 9.11
code/description package/pcs colour

ET076676 440

PVC flange for transom

Е-85 306

ET076677 400

PVC flange for transom

Е-85 307

ET076660 100

PVC flange for transom

Е-85 360

ET076661 100

PVC flange for transom

Е-85 351

E 85 technical catalogue
01.2011 9.12
code/description package/pcs colour

ET076662 100

PVC flange for transom

Е-85 352

ET076663 100

PVC flange for transom

Е-85 353

ET076664 100

PVC flange for transom

Е-85 354

ET076665 100

PVC flange for transom

Е-85 355

E 85 technical catalogue
01.2011 9.13
code/description package/pcs colour

ET076666 100

PVC flange for transom

Е-85 356

ET076667 100

PVC flange for transom

Е-85 357

ET076668 100

PVC flange for transom

Е-85 358

ET076669 100

PVC flange for transom

Е-85 359

E 85 technical catalogue
01.2011 9.14
code/description package/pcs colour

ET076670 100

PVC flange for transom

Е-85 369

ET076622 200

L type flange for ET071152


for transom

Е-85 302

ET076623 200

L type flange for ET071153


for transom

Е-85 303

ET076624 200

L type flange for ET071141


for transom

Е-85 351

E 85 technical catalogue
01.2011 9.15
code/description package/pcs colour

ET076625 200

L type flange for ET071142


for transom

Е-85 352

ET071122 300 MF

T-joint for transom

Е-85302

ET071123 350 MF

T-joint for transom

Е-85303

ET071124 280 MF

T-joint for transom

Е-85304

E 85 technical catalogue
01.2011 9.16
code/description package/pcs colour

ET071125 200 MF

T-joint for transom

Е-85305

ET071126 170 MF

T-joint for transom

Е-85306

ET071127 140 MF

T-joint for transom

Е-85307

ET071131 320 MF

T-joint for transom

Е-85351

E 85 technical catalogue
01.2011 9.17
code/description package/pcs colour

ET071132 300 MF

T-joint for transom

Е-85352

ET071133 280 MF

T-joint for transom

Е-85353

ET071134 210 MF

T-joint for transom

Е-85354

ET071135 180 MF

T-joint for transom

Е-85355

E 85 technical catalogue
01.2011 9.18
code/description package/pcs colour

ET071136 156 MF

T-joint for transom

Е-85356

ET071137 110 MF

T-joint for transom

Е-85357

ET071138 100 MF

T-joint for transom

Е-85358

ET071139 96 MF

T-joint for transom

Е-85359

E 85 technical catalogue
01.2011 9.19
code/description package/pcs colour

ET071144 50 MF

T-btacket for transom 85369

Е-85369

ET71140 100 MF

reinforced T-joint 105 mm


for transom 85 306
2nd level drainage

ET71143 80 MF

reinforced T-joint 150 mm


for transom 85 357
3rd level drainage

ET071152 250 MF

complex fixing part


for transom

Е-85302

E 85 technical catalogue
01.2011 9.20
code/description package/pcs colour

ET071153 150 MF

complex fixing part


for transom

Е-85303

ET071141 300 MF

complex fixing part


for transom

Е-85351

ET071142 150 MF

complex fixing part for transom

Е-85352

E 85 technical catalogue
01.2011 9.21
code/description package/pcs colour frame

ET071130 100 MF

fixing part for structural


glazing 60 mm

ET071109 200 MF

double fixing part combined


with glazing bead E85990

ET071110 100 MF

single fixing part combined


with glazing bead 85990

ET071180 500 MF

aluminium glazing shim


26.5 mm for transoms
3rd level drainage

E 85 technical catalogue
01.2011 9.22
code/description package/pcs colour

ET071181 200 MF

aluminium glazing shim


36.5 mm for transoms
3rd level drainage

ET071185 200 MF

aluminium glazing shim


30 mm for transoms
3rd level drainage

ET071182 350 MF

aluminium glazing shim


32 mm for transoms
2nd level drainage

ET071183 300 MF

aluminium glazing shim


41 mm for transoms
2nd level drainage

E 85 technical catalogue
01.2011 9.23
code/description package/pcs colour

ET071184 350 MF

aluminium glazing shim


36 mm for transoms
2nd level drainage

ET071186 200 MF

additional aluminium glazing shim for


heavy glass panels

ET071187 100 MF

aluminium glazing shim for heavy


glass panels, for transom
2nd level drainage

ET071188 100 MF

aluminium glazing shim for heavy


glass panels, for transom
3rd level drainage

E 85 technical catalogue
01.2011 9.24
code/description package/pcs colour projected window

ET053302 250 MF

die custеd aluminium


joint corner bracket

Е-85410

ET054457 180 MF

extruded aluminium joint


corner bracket 35,8 mm

Е-85410

ET054459 200 MF

extruded aluminium joint


corner bracket 15,6 mm

Е-85200

ET054458 250 MF

extruded aluminium joint


corner bracket 17,2 mm

Е-85400

E 85 technical catalogue
01.2011 9.25
code/description package/pcs colour

ET054461 100 MF

extruded aluminium joint Е-85210


corner bracket 40 mm

Е-85211

ET054462 300 MF

extruded aluminium joint Е-85210


corner bracket 3.5 mm

Е-85211

E 85 technical catalogue
01.2011 9.26
code/description package/pcs colour gaskets

ET130473 80

EPDM gasket
for glazing 3 mm

ET130474 100

EPDM gasket for


glazing 4 mm

ET130462 100

EPDM gasket for


glazing 4 mm

ET130455 100

EPDM gasket for


glazing 5 mm

E 85 technical catalogue
01.2011 9.27
code/description package/pcs colour

ET130181 200

EPDM gasket for


glazing 5 mm

ET130463 80

EPDM gasket for


glazing 6 mm

ET130457 110

EPDM gasket for


glazing 7 mm

ET130458 100

EPDM gasket for


glazing 8 mm

E 85 technical catalogue
01.2011 9.28
code/description package/pcs colour

ET130167 120

EPDM gasket for


glazing 8 mm

ET130479 100

EPDM gasket for


glazing 9 mm

ET130470 100

EPDM gasket for


glazing 10 mm

ET130182 100

EPDM gasket for


glazing 10 mm

E 85 technical catalogue
01.2011 9.29
code/description package/pcs colour

ET130480 100

EPDM gasket for


glazing 12 mm

ET130500 140

EPDM gasket for


pressure plate

ET130553 160

one side butyl seal


tape 45 mm

ET130551 160

two side butyl seal


tape 50 mm

E 85 technical catalogue
01.2011 9.30
code/description package/pcs colour

ET130126 110

silicone gasket for


pressure plate Е85702

ET130705 120

silicone gasket for


structural glazing

ET130180 350

EPDM gasket for


projected window

ET130199 100

EPDM expansion joint gasket

E 85 technical catalogue
01.2011 9.31
code/description package/pcs colour

ET130198 200

EPDM gasket for E85152,


E85153, E85154, E85155

ET130461 110

EPDM gasket for projected


window for profile E85410

ET130706 45

EPDM external gasket for


projected façade with cover plate

ET130707 110

EPDM external gasket for projected


façade window structural glazing

E 85 technical catalogue
01.2011 9.32
code/description package/pcs colour

ET080183 100 бр/pcs

polyamide joint

code/description package/m colour thermal insulation spacers

ET080171 6

thermal insulation
PVC spacer 16 mm

ET080174 6

thermal insulation
PVC spacer 21 mm

E 85 technical catalogue
01.2011 9.33
code/description package/pcs colour

ET080172 6

thermal insulation
PVC spacer 25 mm

ET080173 6

additional (optional) thermal


insulation PVC spacer

ET080177 6

thermal insulation spacer


20
PVC 20x24 mm

24

ET080184 6

thermal insulation 26
spacer PVC 26x28 mm
28

E 85 technical catalogue
01.2011 9.34
code/description package/pcs colour tools

ET162 058 1

jig for opening the fixing holes


on mullion for the spring operated
fixing part ET 071113.00 between
transom-mullion

ET990 520 1

jig for cutting the gasket


ET 130500.00, placed
on the pressure plate for
the horizontal members

ET990 523 1

jig for removing decorative caps

E 85 technical catalogue
01.2011 9.35
code/description package/pcs colour projected window

GI2236 10 MF

connection block for handle


for projected window “NOVA” GI255601
for sash 85 210; 85 211

GI04041 20

antibreack dispositive

GI4020 10

additional locking for projected


window E85 and E8000

BE400R 10 MF

pair of arms for projected window


80 kg for Е85

E 85 technical catalogue
01.2011 9.36
code/description package/pcs colour

BE600R 10 MF

pair of arms for projected window


130 kg for Е85

BE900R 10 MF

pair of arms for parallel opening


for projected window 120 kg
for Е85

BE700R 100 MF

spacers for arms


400R and 600R for E85

BE800R 100 MF

set of nuts for


400R and 600R

E 85 technical catalogue
01.2011 9.37
scheme

FIG 1

E 85 technical catalogue
01.2011 9.38
scheme

оpening angle height


number model length L of sash weight, kg

BE400R adjustable 405 mm 25º 500 to 1200


mm
80 kg

BE600R adjustable 665 mm 15º 1500 to 2000


mm
130 kg

BE800R

installation on friction
arms with nuts

E 85 technical catalogue
01.2011 9.39
scheme

BE900R

width, mm height, mm weight, kg number of scissors

1200 1000 60 3

2000 1500 100 5

1500 2000 120 5

E 85 technical catalogue
01.2011 9.40
CE MARKING

ALUMINIUM AS MATERIAL STANDARDS REQUIREMENTS


curtain wall system E85
Aluminium as material

Aluminium is a very young metal, extracted for the first time in 1854. Commercially produced as a precious
metal from 1886, its industrial production for civil applications only achieved wide use in the 1950’s.

Now aluminium plays a key role for the sustainability of new buildings and the renovation of existing ones.
Thanks to its performance properties aluminium contributes to the energy performance, safety and comfort of
new buildings.

Alloys Finishing
Aluminium in its pure form is a very soft metal. Powder coating – it is a type of paint that is ap-
Thanks to the addition of alloying elements such as plied as a dry powder. Coating is applied on ETEM
copper, manganese, magnesium, zinc, etc. and thanks profiles electrostatically and then is cured under
to suitable production processes, the physical and heat
mechanical properties can be varied in a wide range to allow it to flow and form a ‘’skin’’.
to satisfy the requirements of a large number of
different applications. ETEM is authorized to use the quality sign QUALI-
COAT
ETEM profiles are extruded from the following al- for powder coatings on aluminium for architectural
loys: applications. A wide range of colors and gloss levels
can be achieved.
EN AW-1050 [ Al 99.5 ]
EN AW-6060 [ Al Mg Si ] ETEM also offers timber imitations painting, in addi-
EN AW-6063 [Al Mg0,7 Si] tion to all RAL colors. The technology EZY provides
EN AW-6061 [Al Mg1 Si Cu] the following colors: Golden Oak, Acero, Betulla,
EN AW-6005 [Al Si Mg] Mogano, Verde Scuro, Wenge, Noce Fiammato, Noce
EN AW-6082 [Al Si1 Mg Mn] Chiaro, Ciliegio Rosso, Acacia Scuro, Ciliegio Antico,
Noce Reale, Ciliegio Reale.

Extrusion process Anodizing – it is an electrochemical process where-


by to reinforce the natural oxide film on the alu-
ETEM profiles are obtained through extrusion pro- minium surface, increasing hardness, corrosion and
cess, which consists of pushing a hot cylindrical bul- abrasion resistance. Anodizing gives a very decora-
let of aluminium through a shaped die. The extrusion tive silver matt surface finish, and colored can also
process offers almost infinite range of forms and be obtained by
sections, sealing metallic dyes into the anodized layer.
allowing our designers to integrate numerous func-
tions into one single profile.
Maintenance
Apart from routine cleaning for aesthetic reasons,
ETEM aluminium profiles do not require any mainte-
nance which translates into a major cost and eco-
logical advantage over lifetime of the product.

E 85 technical catalogue
01.2011 10.1
curtain wall system E85
Standards

General Curtain walling


EN 12020 (1÷2) - Aluminium and aluminium alloys - 1/ EN 13830 - Curtain walling - Product standard
Extruded precision profiles in alloys EN AW-6060 2/ EN 13119 - Curtain walling – Terminology
and 3/ CWCT Standard for Systemized Building Envelopes
EN AW-6063 4/ EN 12152 - Curtain walling - Air permeability -
EN 755 (1÷9)– Aluminium and aluminium alloys - Ex- Performance requirements and classification
truded rod/bar, tube and profiles 5/ EN 12153 - Curtain walling - Air permeability -
EN 573 (1÷4) - Aluminium and aluminium alloys - Test method
Chemical composition and form of wrought products 6/ EN 1026 - Windows and doors - Air permeability
EN 15088 – Aluminium and aluminium alloys – Struc- - Test method
tural products for construction works – Technical 7/ EN 12154 -Curtain walling - Watertightness -
conditions for inspection and delivery Performance requirements and classification
EN 1990 Eurocode - Basis of structural design 8/ EN 12155 - Curtain walling - Watertightness -
EN 1991 Eurocode 1 - Actions on structures Laboratory test under static pressure
EN 1998 Eurocode 8 - Design of structures for 9/ ENV 13050 - Curtain walling - Watertightness -
earthquake resistance Laboratory test under dynamic condition of air pres-
EN 1999 Eurocode 9 - Design of aluminium structures sure and water spray
10/ EN 1027 - Windows and doors - Watertightness
- Test method
11/ EN 13116 - Curtain walling - Resistance to wind
load - Performance requirements
12/ EN 12179 - Curtain walling - Resistance to wind
load - Test method
13/ EN 14019 - Curtain Walling - Impact resistance -
Performance requirements
14/ EN ISO 10077 (1÷2) - Thermal performance of
windows, doors and shutters - Calculation of ther-
mal transmittance
15/ EN 12412-2 - Thermal performance of windows,
doors and shutters - Determination of thermal
transmittance by hot box method - Part 2: Frames
16/ ISO 140 (part 1 and 3) - Acoustics - Measure-
ment of sound insulation in buildings and of building
elements
17/ EN 20140 - Acoustics - Measurement of sound
insulation in buildings and of building elements
18/ EN ISO 717-1 - Acoustics - Rating of sound in-
sulation in buildings and of building elements - Part
1: Airborne sound insulation (ISO 717-1:1996)

E 85 technical catalogue
01.2011 10.2
curtain wall system E85
Curtain wall

Ι. Definition
Curtain walling is a form of predominantly vertical
building envelope which supports no load other than
4. Air permeability
its own weight and the environmental forces which An air permeability test shall be carried out in ac-
act upon it. cordance with the corresponding European standard.

In this context non-loadbearing means that, unlike a 5. Watertightness


conventional brick or masonry wall, a curtain wall is
not intended to assist in maintaining the structural A watertightness test shall be carried out in ac-
integrity of the building. Dead and live loads are not cordance with the corresponding European standard.
intended to be transmitted to it from the supporting
structure and thus transmitted to the foundations. 6. Airborne sound insulation
Where specifically required, sound insulation index
ΙΙ. Requirements shall be determined by test.

7. Thermal transmittance
1. Resistance to wind load
Methods of assessment / calculation of thermal
The curtain walling shall be sufficiently rigid to re- transmittance of curtain walling and appropriate
sist the declared wind loads for serviceability, both methods of test are defined in EN 13947.
positive and negative. It shall transfer the declared
wind loads to the building’s structure, safely, via 8. Fire resistance
the fixings for that purpose.
Where specifically required the fire resistance shall
be classified in accordance with the corresponding
2. Dead load (Self-weight) European standard.
The curtain wall shall sustain its self-weight plus
any attachments incorporated into it by original 9. Reaction to fire
design. It shall transfer the weight to the building Where specifically required the reaction to fire shall
structure, safely, via the fixings intended for that be classified in accordance with the corresponding
purpose. European standard.
Self-weights shall be determined in accordance with
EN 1991-1-1 ( Eurocode 1).
10. Fire propagation
Where specifically required the curtain wall shall
3. Resistance against impact incorporate such fire and smoke stops as are nec-
essary to prevent the transmission of fire or smoke
Where specifically required tests shall be performed through voids in the curtain wall construction at its
in accordance with the corresponding European abutment at all levels with structural floor slabs.
standard.

E 85 technical catalogue
01.2011 10.3
curtain wall system E85

11. Durability 15. Thermal shock resistance


Durability of performance of any characteristics Where it is determined that a glass resistant to
of curtain walling is not tested, but is related to thermal shock is required, a suitable strengthened
the results of the conformance of the constituting or toughened glass shall be chosen which conforms
materials and finishes to the state of the art, or, to the appropriate European Standard(s).
where available to European technical specifications
specifying the material or finish.
16. Building and thermal
12. Water vapour permeability movement
Vapour control layers which conform to the appro- The design of curtain wall shall accommodate ther-
priate European Standard shall take into account mal and specified building movements without induc-
the specified hydro-thermal conditions of the ing damage to the components or performance. The
building. façade engineer shall specify the building movements
which the curtain wall will be required to accom-
13. Equipotentiality modate, including movements at joints within the
structure.
Where specifically required the metal component
parts of the curtain wall shall be mechanically 17. Resistance to live
connected together with the building structure to
provide an equipotential bond to the earth circuit horizontal loads
of the building. This is a requirement for all metal
based curtain walling installed into buildings with a The curtain wall shall resist a horizontal live load
height greater than 25 m. The electrical resistance at sill height as specified in EN 1999-1-1 (Eurocode
of the bond of the curtain wall shall not exceed 10 1).
Ω when tested in accordance with EN 13830,
Annex A.

14. Seismic shock resistance


Where specifically required, seismic shock resistance
shall be determined in accordance with technical
specifications or other provisions valid in the place
of use.

NOTE:
The beforementioned definition of curtain wall is extract from CWCT Standard for systemized building envelopes.
The listed requirements for curtain walls are in accordance with harmonized European standard EN 13830.

E 85 technical catalogue
01.2011 10.4
curtain wall system E85
CE marking

What does the sign CE mean? - CE ensures free movement of goods within the EU
and the European Free Trade Association (EFTA);
It is an abbreviation of the French “Conformite
Europeene’’- i.e. European Conformity. By placing - CE permits the withdrawal of products that do
the CE marking the manufacturer declares that the not meet
product complies with general safety requirements the standards by monitoring and custom authorities;
set out in CE marking directives.
- Marking with the CE mark is necessary in cases
where the product is distributed within the internal
What is the purpose of CE market.

marking?
What are the requirements
The CE mark represents ‘’the European passport’’ of
the product, its main objectives are:
for the CE marking?
Curtain walls, not concerned with uses subject to
- CE is a declaration by the manufacturer that the
regulations on reaction to fire, are covered by At-
product meets the essential requirements of rel- testation of conformity system 3 (AoC System 3).
evant European legislation relating to health, safety This system sets the following duties:
and environmental protection;

- CE indicates to officials in relevant ministries and


departments that the product can be put on the
market lawfully in the country;

Tasks to be per- Tasks to be performed by Conformity accessment (the basis for CE marking,
formed by the manu- Notified Body which is set by the final producer)
facturer

EC declaration of conformity issued by the manu-


Factory production Initial Type Testing facturer or his authorized representative based
control - FPC - ITT on the protocol / s from the initial type testing of
the product - ITT

E 85 technical catalogue
01.2011 10.5
curtain wall system E85

Methods for obtaining the results from initial type testing of a


product ITT
According to European legislation, the opportunities for the acquisition of ITT results are three1:

Manufacturers ITT Shared ITT Cascading ITT

Partner (e.g. second Manufactur- The system supplier selects


The manufacturer selects a
er), industry (e.g. hardware pro- samples for testing and im-
sample for testing
ducers) or designer, selects a poses a system of production
sample for testing and imposes control
a system of production control
Notified Body tests the
sample
Notified Body tests the sample

Notified Body tests the sample


The manufacturer owns the
The system supplier owns the
ITT test report
ITT test report

The partner owns the ITT test


report
The manufacturer is allowed
to use the ITT of the system
supplier
The manufacturer is allowed to
use the ITT of his partner.

-Agreement between the manu-


facturer and the system supplier
-Instructions for assembling
The Notified Body checks that and installation of the system
the product is identical supplier relevant for FPC of the
manufacturer
-No reduction of performance
level of product
-System supplier audits activities
The manufacturer owns the ITT
of the manufacturer
test report

ITT of the system supplier as


verification for the manufac-
turer

1 Euro Windoor Guidance sheet, CE marking of windows and pedestrian doors, ©EuroWindoor, Frankfurt 2007

E 85 technical catalogue
01.2011 10.6
curtain wall system E85

What is the cascading initial type testing of the product?

The procedure for cascading ITT that ETEM Building -The manufacturer undertakes to comply uncondi-
Systems as a system supplier offers to the manu- tionally with all instructions of the system supplier
facturers is as follows: for the product assembly and the method of as-
sembly should be identical to the method of assem-
-The system supplier conducts an initial bling of the sample tested by the system supplier.
inspection of FPC of the manufacturer and all ac- The finished product must have the same technical
companying documents; characteristics as the test sample, otherwise the
manufacturer must test his own product;
-Based on the inspection carried out a contract is
concluded with the system supplier; -The system supplier conducts periodic audits of the
manufacturer, provides technical assistance and
-Ratification of the contract permits the manu- training of the staff of the manufacturer, ongoing
facturer to use the results from the ITT of the consultations and information.
system supplier; Based on the factory production
control system and results from the ITT, the manu-
facturer can certify that the product complies with
current regulations and may affix CE marking;

Legal acts
- 89/106/EEC Construction Products Directive;
- Product standard for curtain walling – EN
13830:2004.

E 85 technical catalogue
01.2011 10.7
curtain wall system E85
Hatches for different materials
Hatches for different materials

EPDM butyl seal

PVC membrane

silicone seal
gypsum board
backer rod

silicone seal PVC spacer

Insulation soft 20 mm etalbond

Insulation hard 20 mm sheet aluminium

concrete wall glass

plaster aluminium profile

wood steel

E 85 technical catalogue
01.2011 10.8
curtain wall system E85

Copyright© 2010 ETEM


Building Systems

The design, structure and content of this catalogue ЕТЕМ Building Systems is not responsible for any ty-
are subject of copyright and the exclusive rights pographical errors, technical inaccuracies and following
belong to ETEM Building Systems. Modifying, copying, changes of the content of this catalogue.
publishing, selling or licensing any part or the whole
content of this catalogue are strongly prohibited
without the permission of ETEM Building Systems.
Any unauthorized use of content may violate copy-
right or other laws.

E 85 technical catalogue
01.2011 10.9

You might also like