Professional Documents
Culture Documents
E85 Catalogue TC 1616 PDF
E85 Catalogue TC 1616 PDF
CATALOGUE
CURTAIN - WALL SYSTEM
GENERAL
INFORMATION
CONCEPT ADVANTAGES CERTIFICATES
curtain wall system E85
Concept
Е 85 is a 50 mm façade system.
There are several variations of the system:
3
E 85 technical catalogue
01.2011 1.1
curtain wall system E85
E 85 is a multifunctional system which can be com- The high structural stability of the system is
bined with any kind of glazing and shape as well as achieved with lowest weight of the profiles.
with other materials.
0°C -40°C
E 85 has optimum thermal performance even in
E 85 enables the execution of complex constructions regions with severe weather conditions.
as roofs, cupolas, atriums, pyramids, conservatories.
ISOTHERM 10°C
This system is easy for fabrication in the workshop ISOTHERM 10°C
and effortless to be assembled on ISOTHERM
site. 13°C
E 85 has effective and proved airtightness and and specially constructed supplementary profiles for
watertightness, due to large internal drains on sealing the perimeter of the façade.
three levels, without discontinuity at the junction of
mullions or transoms, carefully designed accessories All characteristics of the system are tested in ift
Rosenheim.
E 85 technical catalogue
01.2011 1.2
curtain wall system E85
E 85 technical catalogue
01.2011 1.3
curtain wall system E85
E 85 with inserted openable parts
projected window
E 85 technical catalogue
01.2011 1.4
curtain wall system E85
Water drainage principles
3rd level
transom
mullion
water
drainage
specially designed
gasket, which
facilitates water
drainage
B 2nd level
transom
The special geometry of E 85 profiles facilitates Gasket seal (A) and foam seal (B) have firming func-
water drainage tion and also make water drainage easier.
Drainage fitting (C) enables water drainage when
The good drainage of this system is achieved by two connecting two mullions.
levels of drainage and by big channels on mullions
and transoms. New flanges (D) and (E) permit thermal expansion of
the profiles.
E 85 technical catalogue
01.2011 1.5
curtain wall system E85
There is an extended range of options for joining mullions and transoms according to the applied loads
Additional joints can be used case of severe loads
E 85 technical catalogue
01.2011 1.6
curtain wall system E85
E85 Thermal Uf = 1,6 -2,9 EN ISO 10077-2 ift Rosenheim 432 31927 / 3
with pressure plate transmittance W/m2.K EN 12412-2
E85 Thermal Uf = 1,6-2,3 EN ISO 10077-2
with additional thermal transmittance W/m2.K EN 12412-2 ift Rosenheim 432 31927 / 4
insulation spacer
E85 Architectural
with glazing Sound Insulation Rw = 39 dB EN ISO 140-3 Technology А5.402.06
6-16-4+4 mm EN 717-1
Laboratory - Greece
E85 EN ISO 140-3 Architectural
with glazing Sound Insulation Rw = 41 dB EN 717-1 Technology А5.403.06
4-20-6+6 mm Laboratory - Greece
E85 EN ISO 140-1
with cover cap Sound Insulation Rw = 35 dB EN 717-1 ift Rosenheim 161 30989/V1
glazing 6-15-5 mm EN 20140-3
E85 EN ISO 140-1
with cover cap glazing Sound Insulation Rw = 44 dB EN 717-1 ift Rosenheim 161 30989/V2
13VSG-20-9 VSG EN 20140-3
E 85 technical catalogue
01.2011 1.7
curtain wall system E85
CLASSIFICATION OF CHARACTERISTICS FOR CURTAIN WALLING
ACCORDING TO EN 13830
Characteristic/Value/dimension Classification/Value
Resistance to wind load
npd Declared values
(kN/m2)
External ЕO Е1 Е2 Е3 Е4
Drop height npd
(no information) (200) (300) (450) (700)
(mm)
Air permeability
Test pressure A1 A2 A3 A4 AE
npd
(Pa) (150) (300) (450) (600) >600
Watertightness
Test pressure R4 R5 R6 R7 RE
npd
(Pa) (150) (300) (450) (600) >600
Thermal transmittance
Ucw npd Declared values
(W/m2.K)
Fire resistance
Integrity (E) npd E15 Е30 E60 E90
i o, o i, o i
E 85 technical catalogue
01.2011 1.8
BUILDING
PHYSICS
DIMENSIONING FORMULAE EXAMPLES
curtain wall system E85
Definition of curtain walling
Curtain walling usually consists of vertical and horizontal structural members, connected together and anchored
to the supporting structure of the building and infilled, to form a lightweight, space enclosing continuous skin,
which provides, by itself or in conjunction with the building construction, all the normal functions of an external
wall, but does not take on any of the load bearing characteristics of the building structure.
The curtain walling shall be sufficiently rigid to resist the declared wind loads for serviceability, both posi-
tive and negative. It shall transfer the declared wind loads to the building’s structure, safely, via the fixings
intended for that purpose.
The stated definition is in accordance with European standards EN 13830 and EN 13119.
Liabilities
The stated data and methods are provided by ETEM always be considered by the structural/ façade engi-
Building Systems as a guideline for calculating wind neer responsible for the project.
loads, dead loads, thermal transmittance coefficient,
etc. The solutions presented in these pages are indicative
and can not cover all possible project cases. Because
The following information does not substitute of all of that every single project has to be evaluated by the
applicable regulations – Eurocodes, harmonized Euro- structural/façade engineer in charge taking into con-
pean standards, national or regional building codes. sideration the specific features, such as climate condi-
tions, location, orientation, etc.
The specific conditions and technical details of every
particular project have to be taken into considera- ETEM Building Systems is not liable for any calculations
tion. and conclusions on the basis of the stated information.
All calculations and specifications must be estimated,
The right choice of all façade elements- mullions, endorsed and guaranteed by architect, engineer, pro-
transoms, fixing elements, etc as well as any special fessional or legal entity authorized by law for such
requirements regarding stability of the façade must activities.
Material properties
Aluminium alloy EN AW 6063 F22
Ultimate tensile strength Rm = 210 N/mm2
Yield strength Rp0,2 = 160 N/mm2
Modulus of elasticity Eal = 70 000 N/mm2 = 7.109 kg/m2
Coefficient of thermal expansion α = 0,023 mm/m .K (up to 1,2 mm/m for difference up to 500C)
E 85 technical catalogue
01.2011 2.1
curtain wall system E85
Wind actions
The main influence over the façade is wind action, As a guideline, the wind pressure values with respect
which depends mainly on the height of the curtain to the structure height are given in the table below:
wall and location.
E 85 technical catalogue
01.2011 2.2
curtain wall system E85
Allowable deflections
In accordance with EN 13830 and Eurocode 9 the or 15 mm, whichever is the less, when measured between
allowable deflections are as follows: the points of support or anchorage to the building’s
structure.
Under the declared wind loads the maximum frontal The maximum deflection of any main horizontal framing
deflection of the curtain walling’s framing members from vertical loads (dead loads) shall not exceed L/500
- mullions and transoms - shall not exceed L/200, or 3 mm, whichever is the less.
For mullions and transoms loaded by wind pressure: For transoms loaded by dead loads:
f = L , or 0,015 m whichever is the less (EN 13830) f = L , or 0,003m, whichever is the less (EN 13830)
200 500
Fixing brackets
Fixing brackets must fulfill the following criteria: mullions and transoms and weight of infill panels
- Transfer safely all loads from the façade result- - Permit movement of mullions caused by thermal ex-
ing from the wind pressure, weight of pansion
y = 0 mm y = ± 12 mm
z = ±12mm x = ± 12 mm x = ±12mm z = 0 mm
E 85 technical catalogue
01.2011 2.3
curtain wall system E85
h movable support - B
h fixed support - A
E 85 technical catalogue
01.2011 2.4
curtain wall system E85
Choosing the the
Choosing appropriate fixing bracket
appropriate fixing bracket
Simply
Simply supported beam with one fixed andone
supported beam with one fixed
movableand one movable support
support
Wpresure/suction
V = g. h . b H = 0-8 m ( middle zone)
v h wind load
g = 0,5 kN/m2
Wind load-pressure f1 = 1,25 dead load
h/
For determining the maximum q = 0,5 kN/m2 A fixed support
permissible wind load the
cp = 0,8 (wind pressure) B movable support
following formulae apply: b b
cp= - 0,5 ( wind suction )
Wp = f1 . q . cp . h/2 . b A
h = 3m
Wind load-suction b = 1,2m Fixed support
Ws = q . cp . h/2 . b
Own weight - dead load
where: V = g . h . b = 0,3 . 3 . 1,2 =
V - load, kN = 1,8 kN
g - weight of mullions, transoms
and infill panels, kN/m2 Wind load
Wp - wind pressure, kN Wp = f1 . q . cp . h/2 . b =
Ws - wind suction, kN = 1,25 . 0,5 . 0,8 . ( 0,5 . 3 ) . 1,2 =
f1 - correction factor
B
= 0,9 kN
q - dynamic load, kN/ m2
cp - correction factor (wind pressure) Ws = q . cp . h/2 . b =
h - floor height, m = 0,5 . (-0,5 ) . (0,5 .3 ) . 1,2 =
b - distance between mullions, m
= (-0,45 ) = 0,45 kN
H - buiding height, m
Movable support
A
Wind load-suction = (-0,45 ) = 0,45 kN
Ws = q . cp . h/2 . b
B
Wpresure/suction
h/
v h
Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
b b Fixing bracket for fixed support must bear both calculated values for dead
A load and wind load.
Movable support Fixing bracket for movable support must bear just wind load.
E 85 technical catalogue
01.2011 2.5
Choosing the appropriate fixing bracket
Continuous simply supported beam
curtain wall system E85
Choosing the appropriate fixing bracket
Continuous simply supported beam
h/
A h/
wind load h
dead load
Finally we choose the appropriate fixing bracket with bigger bearing A fixed support
b b
capacity than the calculated value. A
Fixing bracket for fixed support must bear both calculated values for dead Movable support
load and wind load.
E 85 technical catalogue
01.2011 2.6
Choosing the appropriate fixing bracket
Continuous beam with one fixed and two movable supports
B
vh
Wpresure/suction
Fixed support Example
B B
h
Own weight - dead load Initial data:
h/ V = g . 2h . b H = 0-8 m ( middle zone)
b b g = 0,5 kN/m2
A Wind load-pressure f1 = 1,25
h For determining the maximum q = 0,5 kN/m2
Fixed support permissible wind load the cp = 0,8 (wind pressure)
following formulae apply: cp= - 0,5 ( wind suction )
Wp = f1 . q . cp . h/2 . b h = 3,3m
B Wind load-suction b = 0,9m
B Ws = q . cp . h/2 . b
v h
Wpresure/suction
B
h
wind load
dead load b b
A
A fixed support
Movable support ( end)
B movable support Movable support ( end)
Wind load
Wind load-pressure Wp = f1 . q . cp . h/2 . b =
For determining the maximum = 1,25 . 0,5 . 0,8 .( 0,5 . 3,3 ) . 0,9 =
permissible wind load the = 0,74 kN
following formulae apply:
Wp = f1 . q . cp . h/2 . b
Movable support ( middle ) Wind load Ws = q . cp . h/2 . b =
Wp = f1 . f2 . q . cp . h . b = Wind load-suction = 0,5 . (-0,5) . ( 0,5 . 3,3 ) . 0,9 =
Wind load-pressure = 1,25 . 1,25 . 0,5 . 0,8 . 3,3 . 0,9 = Ws = q . cp . h/2 . b = (-0,37) = 0,37 kN
For determining the maximum = 1,86 kN
permissible wind load the
following formulae apply: Ws = f2 . q . cp . h . b =
Wp = f1 . f2 . q . cp . h . b = 1,25 . 0,5 . (-0,5) . 3,3 . 0,9 =
= (-0,93) = 0,93 kN
Wind load-suction
Ws = f2 . q . cp . h . b Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
where: Fixing bracket for fixed support must bear both calculated values for dead
f2 - correction factor load and wind load.
Fixing bracket for movable support must bear just wind load.
E 85 technical catalogue
01.2011 2.7
Choosing the appropriate fixing bracket
curtain wall
Continious supported system
beam with one fixed support in the middle and two movable in the end E85
Choosing the appropriate fixing bracket
Continuous supported beam with one fixed support in the middle and two movable in the end
Fixed support Example
Movable support
B
Wind load-pressure Wind load v h
Wpresure/suction
B Fixed support
v h
Wpresure/suction
wind load A
h
dead load Finally we choose the appropriate fixing bracket with bigger bearing capacity
h/
A fixed support than the calculated value.
B movable support b b Fixing bracket for fixed support must bear both calculated values for dead
B
load and wind load.
Movable support Fixing bracket for movable support must bear just wind load.
E 85 technical catalogue
01.2011 2.8
curtain wall system E85
choosing the appropriate choosing the appropriate choosing the appropriate choosing the appropriate
mullion with Jx mullion with Jx transom with Jx transom with Jy
exceeding or equal exceeding or equal exceeding or equal exceeding or equal
to the required Jx to the required Jx to the required Jx to the required Jy
E 85 technical catalogue
01.2011 2.9
curtain wall system E85
Selection of mullion
Wind load actions
1. Simply supported beam
Trapezoidal load
The moment of inertia of a mullion, supported at
two points, subjected to wind load is given by the
following equation: h f h
2
Jxa = w . (a/2) . h . 108 . 25 - 40 (a/2)
4
+16 (a/2)2
1920 . Eal . f h2 h2
2 2 a/2 b/2
Jxb = w . (b/2) . h . 108 . 25 - 40 (b/2) +16 (b/2)
4
1920 . Eal . f h 2 h 2 a b
where:
Jx - moment of inertia,cm4 2
w - wind pressure, kg/m2 Jxa = w . (a/2) . h . 108 . 25 - 40 .(a/2)
4
+16 . (a/2)2 =
a, b - distance betweenmullions,m 1920 . Eal . f h2 h2
h - distance between fixing brackets,m
Eal - modulus of elasticity, kg/m2 = 60 . (1,5/2) . 44 . 108 . 25 - 40 . (1,5/2)2 +16 .(1,5/2)2 =
f - deflection,m 1920 . 7. 109 . 0,015 42 42
Example:
Total required moment of inertia:
Initial data:
a = 1.5 m Jx = Ja + Jb = 138,0 + 111,8 = 249,8 cm2
b = 1.2 m
h=4m The appropriate mullion is E 85104 with
w = 60 kg/m2
Jx = 252,5 cm4
Eal = 7.109 kg/m2
f = l = 4 = 0,02>0,015m
200 200
f = 0,015 m in the following formulae :
E 85 technical catalogue
01.2011 2.10
curtain wall system E85
2. Continuous beam
Rectangular load
The required moment of inertia of a mullion, sup-
ported at three points, subjected to wind load is f
given by the following equation: h
Jxa = w . (a/2) . h . 10
4 8
185 . Eal . f
a/2 b/2
a b
Jxb = w . (b/2) . h . 10
4 8
185 . Eal . f f
where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2
a, b - distance between mullions,m
h - distance between fixing brackets,m
Jxa = w . (a/2) . h . 10 = Jxb = w . (b/2) . h . 10 =
4 8 4 8
Eal - modulus of elasticity, kg/m2
f - deflection,m 185 . Eal . f 185 . Eal . f
E 85 technical catalogue
01.2011 2.11
curtain wall system E85
Selection of transom
Wind load actions
l ≤1 Jx = w . (h0/2) . l . 10
8
h0
h0 120 . Eal . f
h0
l
2 2
Jx = w . (h0/2) . l . 108 . 25 - 40 . (h0/2) +16 . (h0l2/2)
4
l >1
h0 1920 . Eal . f l2 l
h0
where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2 l
l - length of transom, m l
Eal - modulus of elasticity, kg/m2
f - deflection,m
h0 - distance between transoms, m
The appropriate transom is E 85300 with Jx = 2,7 cm
For mullions and transoms loaded by wind pressure:
Initial data:
l l=2m
f= h0 = 1.5 m
200
w = 60 kg/m2
or 0,015 m whichever is the less (EN 13830) Eal = 7.109 kg/m2
1920 . Eal . f l l
l = 1,2 = 0,4≤1
h0 3 = 60 . (1.5/2) . 24 . 108 . 25 - 40 . (1,5/2)2+16 . (1.5/2)2 =
1920 . 7 . 109 . 0,01 22 22
f= l = 1,2 = 0,006 >0,015m
= 11,6 cm4
200 200
The appropriate transom is E 85302 with Jx = 19,5 cm
f = 0, 006 m in the following formula :
Important note : This selection of transoms is not final!
Jx = w . (h0/2) . l . 10 = 60 . (3/2) . 1.2 9. 10 = 2,1 cm4
8 8
We choose the appropriate profile which characteristics
120 . Eal . f 120 . 0,006 . 10 . 7 exceed or are equal to both calculated values Jx and Jy.
E 85 technical catalogue
01.2011 2.12
curtain wall system E85
Calculation of the required glass pane thickness
Weight of the glass pane G is calculated as follows:
G=t. ρglass . lg . hg
where: 10 . lg . hg . w 10 . 2 .1,5 . 60
t - minimum theoretical thickness, mm t= = = 5mm
72 72
ρ glass - specific weight of glass = 2,5 kg/m2 x mm
lg - the smallest dimension of the glass pane,m
hg - the largest dimension of the glass pane,m For double glazing treq = 5 . 1,5 = 7,5 mm
hg lg . 10 . w
<3 t=
lg 4,9
hg 1,5
= = 0,75 ≤ 3
lg 2
E 85 technical catalogue
01.2011 2.13
curtain wall system E85
Glass pane weight
The required moment of inertia of a transom due to G
the weight of the glass pane is given by:
G/2 G/2
Jy1 = G . a . 10 . (3 . l2 - 4 . a2)
8
48 . Eal . f1
a a
l
Jy1 = G . a . 10 . (3 . l2 - 4 . a2) =
8
f=
500 48 . Eal . f
Use ETEM catalogue to choose the appropriate tran- We choose the appropriate profile which characteristics
som with Jy exceeding or equal to the required Jy. exceed or are equal to both calculated values
Jx = 19,5 cm4 and Jy = 15,9 cm4
Use ETEM catalogue to choose the appropriate
profile which characteristics exceed or are equal to The appropriate transom is E 85303 with
both calculated values Jx and Jy. Jx = 45,8 cm4 and Jy = 21,5 cm4
E 85 technical catalogue
01.2011 2.14
curtain wall system E85
Thermal transmittance coefficient Ucw of curtain wall
2- 5-
6 2 5
Am
L3
6 Af
1
1 Ag At
2 1
L L2 1
4 2
4 Ap 3- 6-
3 4
4 3 6
L1
5
5 3
Ag 5 At At
6
5 Af
E 85 technical catalogue
01.2011 2.15
curtain wall system E85
E 85 technical catalogue
01.2011 2.16
TABLES
50
X 6,6 m Ix = 27,70 cm4 Iy = 19,39 cm4
2006 g/m Wx = 6,96 cm3 Wy = 7,75 cm3
E 85100 mullion Y
50
448 mm ex = 2,50 cm еy = 3,98 cm
149 mm ix = 1,93 cm iy = 1,62 cm
66
70
X 6,6 m Ix = 58,04 cm4 Iy = 23,79 cm4
2211 g/m Wx = 12,19 cm3 Wy = 9,51 cm3
E 85101 mullion Y
50
90
X 6,6 m Ix = 104,15 cm4 Iy = 28,19 cm4
2417 g/m Wx = 18,65 cm3 Wy = 11,27 cm3
E 85102 mullion Y
50
110
X 6,6 m Ix = 169,00 cm4 Iy = 33,43 cm4
Y 2665 g/m Wx = 26,15 cm3 Wy = 13,37 cm3
E 85103 mullion
50
130
X 6,6 m Ix = 252,55 cm4 Iy = 38,03 cm4
Y 2881 g/m Wx = 34,40 cm3 Wy = 15,21 cm3
E 85104 mullion
50
160
X 6,6 m Ix = 417,97 cm4 Iy = 44,95 cm4
3205 g/m Wx = 46,90 cm3 Wy = 17,98 cm3
E 85105 mullion Y
50
E 85 technical catalogue
01.2011 3.1
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
180
X 6,6 m Ix = 752,98 cm4 Iy = 60,74 cm4
4628 g/m Wx = 74,89 cm3 Wy = 24,30 cm3
E 85106 mullion Y
50
200
X 6,6 m Ix = 1003,76 cm4 Iy = 71,32 cm4
5165 g/m Wx = 91,01 cm3 Wy = 28,53 cm3
E 85107 mullion Y
50
200
X 6,6 m Ix = 1326,00 cm4 Iy = 80,93 cm4
Y 6423 g/m Wx = 116,21 cm3 Wy = 32,37 cm3
E 85108 mullion
50
230
X 6,6 m Ix = 2161,67 cm4 Iy = 110,05 cm4
Y 8416 g/m Wx = 162,85 cm3 Wy = 44,02 cm3
E 85109 mullion
50
X
split 1320 g/m Wx = 6,96 cm3 Wy = 1,87 cm3
E 85152 mullion Y
382 mm ex = 1,44 cm еy = 4,84 cm
90 114 mm ix = 2,62 cm iy = 0,74 cm
X
split 1536 g/m Wx = 10,58 cm3 Wy = 2,40 cm3
E 85153 mullion Y
422 mm ex = 1,41 cm еy = 5,77 cm
110 134 mm ix = 3,27 cm iy = 0,77 cm
E 85 technical catalogue
01.2011 3.2
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
22.5 X
6,6 m Ix = 99,63 cm4 Iy = 4,09 cm4
split 1752 g/m Wx = 14,85 cm3 Wy = 2,94 cm3
E 85154 mullion Y
462 mm ex = 1,39 cm еy = 6,71 cm
130 154 mm ix = 3,92 cm iy = 0,79 cm
X
split 2076 g/m Wx = 22,39 cm3 Wy = 3,75 cm3
E 85155 mullion Y
523 mm ex = 1,37 cm еy = 8,15 cm
160 184 mm ix = 4,87 cm iy = 0,82 cm
35.3
X 6,6 m Ix = 36,82 cm4 Iy = 18,31 cm4
mullion for 2311 g/m Wx = 8,70 cm3 Wy = 7,29 cm3
E 85120 substructure Y
50
6,6 m
7.5
E 85 technical catalogue
01.2011 3.3
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X
X
90
X
6,6 m Ix = 6,14 cm4 Iy = 5,17 cm4
suppl. 999 g/m Wx = 2,79 cm3 Wy = 2,07 cm3
Y
E 85140 mullion
50
X
outer 6,6 m Ix = 3,38 cm4 Iy = 3,38 cm4
44
Y
35.7
E 85 technical catalogue
01.2011 3.4
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
15
X 6,01 m Ix = 2,78 cm4 Iy = 7,64 cm4
1015 g/m Wx = 1,33 cm3 Wy = 3,06 cm3
E 85300 2nd level Y
50
transom 300 mm ex = 2,50 cm еy = 2,10 cm
79 mm ix = 0,86 cm iy = 1,43 cm
31
29
X 6,01 m Ix = 7,12 cm4 Iy = 11,55 cm4
1293 g/m Wx = 2,76 cm3 Wy = 4,62 cm3
E 85301 2nd level Y
50
49
X 6,01 m Ix = 19,52 cm4 Iy = 15,08 cm4
1455 g/m Wx = 6,00 cm3 Wy = 6,03 cm3
E 85302 2nd level Y
50
69
X 6,01 m Ix = 45,83 cm4 Iy = 21,60 cm4
1785 g/m Wx = 10,54 cm3 Wy = 8,64 cm3
E 85303 2nd level Y
50
89
X 6,01 m Ix = 98,87 cm4 Iy = 26,45 cm4
2276 g/m Wx = 18,06 cm3 Wy = 10,58 cm3
E 85304 2nd level Y
50
109
X 6,01 m Ix = 160,52 cm4 Iy = 31,06 cm4
2492 g/m Wx = 25,02 cm3 Wy = 12,42 cm3
E 85305 2nd level Y
50
E 85 technical catalogue
01.2011 3.5
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
129
X 6,01 m Ix = 240,58 cm4 Iy = 35,67 cm4
2708 g/m Wx = 32,66 cm3 Wy = 14,27 cm3
E 85306 2nd level Y
50
159
X 6,01 m Ix = 398,72 cm4 Iy = 42,59 cm4
3032 g/m Wx = 45,28 cm3 Wy = 17,04 cm3
E 85307 2nd level Y
50
E 85 technical catalogue
01.2011 3.6
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6
50
transom 204 mm ex = 2,50 cm еy = 1,18 cm
62 mm ix = 0,43 cm iy = 1,30 cm
16
15
X 6,01 m Ix = 1,49 cm4 Iy = 7,42 cm4
948 g/m Wx = 0,94 cm3 Wy = 2,97 cm3
E 85360 3rd level Y
50
35
X 6,01 m Ix = 8,70 cm4 Iy = 12,03 cm4
1164 g/m Wx = 3,69 cm3 Wy = 4,81 cm3
E 85351 3rd level Y
50
55
X 6,01 m Ix = 24,25 cm4 Iy = 16,64 cm4
1380 g/m Wx = 7,37 cm3 Wy = 6,65 cm3
E 85352 3rd level Y
50
75
X 6,01 m Ix = 58,19 cm4 Iy = 21,49 cm4
1874 g/m Wx = 12,82 cm3 Wy = 8,60 cm3
E 85353 3rd level Y
50
95
X 6,01 m Ix = 102,48 cm4 Iy = 26,10 cm4
2090 g/m Wx = 18,46 cm3 Wy = 10,44 cm3
E 85354 3rd level Y
50
E 85 technical catalogue
01.2011 3.7
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
115
X 6,01 m Ix = 162,24 cm4 Iy = 30,71 cm4
2306 g/m Wx = 24,72 cm3 Wy = 12,29 cm3
E 85355 3rd level Y
50
135
X 6,01 m Ix = 239,09 cm4 Iy = 35,32 cm4
2522 g/m Wx = 31,58 cm3 Wy = 14,13 cm3
E 85356 3rd level Y
50
165
X 6,01 m Ix = 389,88 cm4 Iy = 42,24 cm4
2846 g/m Wx = 42,93 cm3 Wy = 16,90 cm3
E 85357 3rd level Y
50
185
X 6,01 m Ix = 516,42 cm4 Iy = 46,85 cm4
3062 g/m Wx = 51,19 cm3 Wy = 18,74 cm3
E 85358 3rd level Y
50
205
X 6,01 m Ix = 665,65 cm4 Iy = 51,46 cm4
3278 g/m Wx = 60,01 cm3 Wy = 20,58 cm3
E 85359 3rd level Y
50
235
X 6,01 m Ix = 882,24 cm4 Iy = 58,94 cm4
3448 g/m Wx = 71,59 cm3 Wy = 23,58 cm3
E 85369 3rd level Y
50
E 85 technical catalogue
01.2011 3.8
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
21.2
X 6,01 m Ix = 1,67 cm4 Iy = 8,74 cm4
3rd level 820 g/m Wx = 1,54 cm3 Wy = 3,50 cm3
Y
E 85380 hidden
50
175 mm ex = 2,50 cm еy = 1,09 cm
transom 91 mm ix = 0,74 cm iy = 1,70 cm
21.2
split transom
60 mm ix = 1,35 cm iy = 1,09 cm
29
45
split transom
77 mm ix = 2,22 cm iy = 1,15 cm
55
65
Y
E 85410 frame 415 mm ex = 3,19 cm еy = 4,83 cm
186 mm ix = 2,77 cm iy = 1,34 cm
90.3
X
6,01 m Ix = 12,87 cm4 Iy = 4,62 cm4
Y 886 g/m Wx = 3,55 cm3 Wy = 1,49 cm3
49
E 85 technical catalogue
01.2011 3.9
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X
6,01 m Ix = 30,90 cm4 Iy = 8,15 cm4
sash for Y 1416 g/m Wx = 7,57 cm3 Wy = 1,92 cm3
E 85211
49.5
6,01 m
external 208 g/m
E 85614 glass
27.9
99 mm
support 19.2 43 mm
6,01 m
external
14.8
200 g/m
E 85615 glass 101 mm
support 22 46 mm
4,4 m
4.3
E 85 technical catalogue
01.2011 3.10
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
4,40 m
4.7
operating 197 g/m
E 2309 rod 55 mm
23.5
0 mm
6,01 m
4.8
130 g/m
E 85915 spacer 66 mm
19 0 mm
6,01 m
10.2
6,01 m
pressure 655 g/m
E 85745 plate 205 mm
47.6
0 mm
6,01 m
10.2
6,01 m
pressure
5.5
416 g/m
E 85702 plate for 113 mm
50
slope > 15° 54 mm
E 85 technical catalogue
01.2011 3.11
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
pressure 1034 g/m
25.9
E 85703 plate for 305 mm
angle 7.5° 70.7 51 mm
6,01 m
pressure 1121 g/m
E 85704 plate for
28.2
327 mm
angle 15° 63 mm
80.8
6,01 m
pressure 1204 g/m
E 85705 plate for
31.6
349 mm
angle 22.5° 74 mm
89.8
6,01 m
pressure 1291 g/m
E 85706 plate for
35.9
371 mm
angle 30° 86 mm
97
6,01 m
pressure 1455 g/m
E 85707 plate for 413 mm
44
6,01 m
pressure 1620 g/m
E 85708 plate for 455 mm
53.8
E 85 technical catalogue
01.2011 3.12
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
19.1
pressure 510 g/m
E 85740 plate for 170 mm
corner 90° 42.2
0 mm
6,01 m
pressure
18.2
508 g/m
E 85741 plate for 169 mm
corner 135° 46.2 0 mm
6,01 m
12.3
6,01 m
cover cap 126 g/m
6
6,01 m
10.2
6,01 m
4.9
E 85 technical catalogue
01.2011 3.13
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
cover 289 g/m
E 85711
50
cap 144 mm
12 75 mm
6,01 m
cover 332 g/m
E 85712 cap
50
166 mm
15 81 mm
6,01 m
cover 400 g/m
E 85713 cap
50
191 mm
20 91 mm
6,01 m
cover 432 g/m
E 85714 cap
50
211 mm
25 101 mm
6,01 m
cover 467 g/m
E 85715 cap
50
231 mm
30 111 mm
6,01 m
cover 821 g/m
E 85716 cap
50
291 mm
60 171 mm
E 85 technical catalogue
01.2011 3.14
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
cover 1779 g/m
E 85718 cap
50
506 mm
165 381 mm
6,01 m
cover 467 g/m
E 85720 cap
50
206 mm
25
121 mm
6,01 m
cover 281 g/m
E 85721 cap
50
150 mm
18
77 mm
6,01 m
cover 462 g/m
E 85722 cap
50
231 mm
40
110 mm
6,01 m
cover 1207 g/m
E 85723 cap
50
337 mm
100 216 mm
6,01 m
cover 1627 g/m
E 85724 cap
50
453 mm
160
333 mm
E 85 technical catalogue
01.2011 3.15
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
cover 262 g/m
E 85730 cap
50
132 mm
12
67 mm
6,01 m
17.6
6,01 m
20.4
6,01 m
cover cap - g/m
E 85790 inox
51
- mm
15
- mm
6,01 m
cover cap - g/m
E 85791 inox
51
- mm
- mm
20
E 85 technical catalogue
01.2011 3.16
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
E 85 technical catalogue
01.2011 3.17
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
E 85 technical catalogue
01.2011 3.18
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
insert X
Y 764 g/m Wx = 2,04 cm3 Wy = 1,04 cm3
E 85972 for E 85152 93 mm ex = 0,78 cm еy = 1,60 cm
31.9 iy = 0,54 cm
0 mm ix = 1,07 cm
insert X
Y 1034 g/m Wx = 4,60 cm3 Wy = 1,59 cm3
E 85973 for E 85153 133 mm ex = 0,78 cm еy = 2,60 cm
51.9
0 mm ix = 1,77 cm iy = 0,57 cm
insert X
Y 1304 g/m Wx = 7,87 cm3 Wy = 2,14 cm3
E 85974 for E 85154 173 mm ex = 0,78 cm еy = 3,60 cm
71.9 0 mm ix = 2,42 cm iy = 0,59 cm
insert X
Y 1709 g/m Wx = 14,04 cm3 Wy = 2,97 cm3
E 85975 for E 85155 233 mm ex = 0,78 cm еy = 5,10 cm
101.9 0 mm ix = 3,36 cm iy = 0,60 cm
E 85 technical catalogue
01.2011 3.19
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
8.7
97 g/m
6
E 85640 spacer 6 mm 59 mm
10
6 mm
6,01 m
12.7
10
130 g/m
E 8611 spacer 10 mm 82 mm
10
10 mm
6,01 m
14.7
140 g/m
12
E 85641 spacer 12 mm 90 mm
10
12 mm
6,01 m
20.7
200 g/m
E 85642 spacer 18 mm
18
10
98 mm
18 mm
6,01 m
9.9
101 g/m
6
6,01 m
11.3
6.2
108 g/m
E 85651 spacer 15° 65 mm
10
6 mm
E 85 technical catalogue
01.2011 3.20
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
12.8
117 g/m
6.5
E 85652 spacer 22,5° 69 mm
10
7 mm
6,01 m
14.6
128 g/m
6.9
6,01 m
16.8
7.5
142 g/m
E 85654 spacer 37,5° 82 mm
10
8 mm
6,01 m
19.8
8.5
161 g/m
E 85655 spacer 45° 93 mm
10
9 mm
6,01 m
spacer for
9.3
70 g/m
33 879 structural 53 mm
glazing 0 mm
11
E 85 technical catalogue
01.2011 3.21
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
19.3 6,01 m
spacer for 229 g/m
E 85990 structural
24
138 mm
glazing 0 mm
6,01 m
spacer for 139 g/m
9
33 501 structural 71 mm
glazing 16
0 mm
22 6,01 m
8.9
6,01 m
8.6
596 g/m
E 85920 glazing clip 110 mm
43.6 0 mm
6,01 m
602 g/m
10
6,01 m
17.2
E 85 technical catalogue
01.2011 3.22
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
17.2
glazing 408 g/m
E 85916 support 130 mm
48.9 0 mm
6,01 m
17.2
2,01 m
9.7
6,01 m
9.7
2,01 m
glazing 306 g/m
9.7
E 85914 support 99 mm
39.8
0 mm
E 85 technical catalogue
01.2011 3.23
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X
210
210
suppl. 6,01 m
5
E 85 technical catalogue
01.2011 3.24
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
X
5,00 m Ix = 37,13 cm4 Iy = 37,13 cm4
insert 1847 g/m Wx = 12,38 cm3 Wy = 12,38 cm3
7528 for E 85130
Y
239 mm ex = 3,00 cm еy = 3,00 cm
60
0 mm ix = 2,33 cm iy = 2,33 cm
60
6,01 m
suppl. 1246 g/m
E 85966 profile for
44.2
207 mm
louvers 0 mm
29.6
6,01 m
drainage 240 g/m
E 85911
40.3
profile 122 mm
0 mm
17.5
6,01 m
profile
13.8
283 g/m
E 85904 for spring 46 mm
connector 15.3 0 mm
6,01 m
spacer for 448 g/m
E 85290 etalbond
23
126 mm
21.1 0 mm
E 85 technical catalogue
01.2011 3.25
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
6,01 m
19
spacer for 400 g/m
E 85291 etalbond 134 mm
25.1 0 mm
6,01m
suppl. profile 176 g/m
7.5
6,01 m
suppl. profile
24.5
346 g/m
E 85611 for sealing 176 mm
membrane 0 mm
43
6,01 m
suppl. profile
24.5
381 g/m
E 85612 for sealing 170 mm
membrane 0 mm
43
6,01 m
wall 984 g/m
E 85620 attachment 277 mm
40
profile 0 mm
70
6,01 m
wall 999 g/m
E 85621 attachment 285 mm
40
profile 0 mm
74
E 85 technical catalogue
01.2011 3.26
curtain wall system E 85
length
weight
code description profile statical values
ext. perimeter
vis. perimeter
25
6,01 m
cover cap 479 g/m
E 8700
60
anti-burglar 231 mm
111 mm
23
6,01 m
cover cap 460 g/m
E 8701
60
anti-burglar 223 mm
107 mm
6,01 m
9.6
6,01 m
flat bar 1350 g/m
10
6,01 m
cover 1312 g/m
E 85727 cap
50
388 mm
251 mm
100
E 85 technical catalogue
01.2011 3.27
PROFILES
6.4 6,01 m
15.6
E 85 technical catalogue
01.2011 3.28
curtain wall system E 85
mullions, inserts, connectors and flush transoms 2nd and 3rd level
2nd level 2nd level flush 3rd level 3rd level flush hidden
roof
code insert flush transom + suppl. flush transom + suppl.
connector
transom Profile transom profile
E 85100 - E 85960 E 85302 - E 85352 -
E 85101 E 85951 E 85960 E 85303 E 85300+E 85600 E 85353 E 85380+E 85600
E 85102 E 85952 E 85960 E 85304 E 85300+E 85601 E 85354 E 85380+E 85601
E 85103 E 85953 E 85960 E 85305 E 85300+E 85602 E 85355 E 85380+E 85602
E 85104 E 85954 E 85960 E 85306 E 85300+E 85603 E 85356 E 85380+E 85603
E 85105 E 85955 E 85960 E 85307 - E 85357 -
E 85106 E 85956 E 85969 - - E 85358 -
E 85107 E 85957 E 85969 - - E 85359 -
E 85108 E 85958 E 85969 - - E 85359 -
E 85109 E 85969 E 85969 - - E 85369 -
E 85 technical catalogue
01.2011 4.1
curtain wall system E85
mullions
24.5 5 144.5 6 194 6
10
2.8
2.5
20
10
insert E 85956
50
44.4
45
50
50
10
20 10 20
insert E 85957
10
10 10 10 10
20
16
E 85106 E 85107
2.8
2.5
10
16 180 200
2.5
24.5 8 155.5 12
50
3
10
19
20
E 85100
10
insert E 85958
4
44
50
50
10
insert E 85951
86
70
39
E 85101
10
20
4
E 85108
10
insert E 85952
3
106
90
59
E 85102 16 200
216
4
insert E 85953
126
110
79
4
10
insert E 85954
146
130
20
99
42
50
50
10
insert E 85955
10
176
160
129
20
E 85105 E 85109
10
4
4
46 16 230
2 2
246
scale 1:1 50
E 85 technical catalogue
01.2011 4.2
curtain wall system E 85
split mullions, inserts and flush transoms 2nd and 3rd level
2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom Profile transom profile
E 85152 E 85972 E 85304 E 85300+E 85601 E 85354 E 85380+E 85601
E 85153 E 85973 E 85305 E 85300+E 85602 E 85355 E 85380+E 85602
E 85154 E 85974 E 85306 E 85300+E 85603 E 85356 E 85380+E 85603
E 85155 E 85975 E 85307 - E 85357 -
E 85 technical catalogue
01.2011 4.3
curtain wall system E 85
split mullions supplementary profiles for split mullions
68.8
45.8
90
16.3 32
32.7
insert E 85972
E 85152
insert E 85973
52.7
E 85153
110
insert E 85974
72.7
E 85154
130
mullion E 85155
insert E 85975
102.7
E 85155
13.5
160
E 85151
suppl. profile E 85151
22.5 32 mullion E 85155
scale 1:1
E 85 technical catalogue
01.2011 4.4
curtain wall system E 85
mullion for substructure & cover cap
50
E 85120
20 10 20
10 10 10 10
16
E 85350
E 85300
24.5
35.3
2.5
E 85301/E 85351
81
65
E 85302/E 85352
38
26.4
27.7
2
2nd level
code 3rd level transom
transom
scale 1:1
E 85 technical catalogue
01.2011 4.5
curtain wall system E 85
mullion 90°
20 10 10 10 15.5 40.5
10 10 10 10 15.5 24.5
16
40.5
24.5
2.5
15.5
15.5
106
90
10
10
2.5 2.5
60.5
10
10
60.5
10
10
20
2.5
10
E 85130 90 16
106
insert 7528
2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom profile transom Profile
E 85130 7528 E 85304 E 85300+E85601 E 85354 E 85380+E 85601
scale 1:1
E 85 technical catalogue
01.2011 4.6
curtain wall system E 85
mullion 135°
cover cap E 85732
pressure plate E 85741
24
16
10
10
45°
118 90
1 6 .3
6 0 .8
119.7
insert E 85973
E 85135
135°
7 6 .9
76.9
22.5°
142.1
2nd level 2nd level flush 3rd level 3rd level flush hidden
code insert flush transom + suppl. flush transom + suppl.
transom Profile transom profile
scale 1:1 E 85135 E 85973 E 85304 E 85300+E85601 E 85354 E 85380+E 85601
E 85 technical catalogue
01.2011 4.7
curtain wall system E 85
supplementary mullion profile
30°-90°
split rotating mullion
40.1
E 85140
50
any mullion
30
10 20
16
36
26.5
23.3
55.6
19.6
E 85141
E 85 technical catalogue
01.2011 4.8
curtain wall system E 85
inner supplementary mullion profile 90°
48
19.8
48.2
14.9
90
°
E 85142
3.3
any mullion
scale 1:1
E 85 technical catalogue
01.2011 4.9
curtain wall system E 85
outer supplementary mullion profile 90°
35.7
44
4.4
.3
31.3
5 26.3
E 85143
26.3
31.3
35.7
4.4
5
any mullion
scale 1:1
E 85 technical catalogue
01.2011 4.10
curtain wall system E 85
E 85 technical catalogue
01.2011 4.11
curtain wall system E85
1.5
2
10
10
23.5
20
20
∅1
7
10
10
∅1
4
47
46
50
50
50
10
10
10
10
20
20
E 85301 E 85302 E 85303 E 85304 E 85305 E 85306 E 85307
10
10
2
1.5
16 15 16 29 49 69 89 109 129 159
31 45 65 85 105 125 145 175
2 2 2 2 2 2 2 2 2 2
6 7 27 47 67 87 107 127 157 177 197 226 3
E 85350 E 85360
2
11
11
20
20
∅1 23.5
7
9
∅1
4
46
50
50
50
10
10
9
9
20
20
E 85351 E 85352 E 85353 E 85354 E 85355 E 85356 E 85357 E 85358 E 85359 E 85369
11
11
2
10 6 10 15 35 55 75 95 115 135 165 185 205 235
16 25 45 65 85 105 125 145 175 195 215 245
scale 1:1
E 85 technical catalogue
01.2011 4.12
curtain wall system E 85
2nd level supplementary transoms
1.5
1.4
55.2
58
55
58
15.2
1.4
1.5
69 89 109 129
2
6 13.2
2
11
46
50
28
50
11
E 85380
2
21.2
scale 1:1
E 85 technical catalogue
01.2011 4.13
curtain wall system E 85
3rd level split transom for conservatory
transom E 85370
suppl. profile E 85670
30°-9
0°
10
10
40
9
27.5
E 85370
11
55 10
65
supplementary profile for E 85370 2nd level split transom for conservatory
transom E 85320
51
30°-9
0°
12
E 85320
68.9
13.2
10
42
32
10
E 85670
20
10
29 16
45
scale 1:1
E 85 technical catalogue
01.2011 4.14
curtain wall system E 85
frame for thermo-break projected and parallel opening windows
RAL 9005
E 85410
16
60 30.3
90.3
appropriate transom 2nd and 3rd level for frame operating rods
19.7
code 2nd level transom 3rd level transom
4.3
E 85303 E 85353
E 2308
E 85304 E 85354
E 85305 E 85355
E 85306 E 85356
E 85410 23.5
E 85307 E 85357
- E 85358
- E 85359
4.7
- E 85369
E 2309
note: frame E 85410 is suitable for
sashes E 85210 and E 85211 spacer
19
E 85915
4.8
scale 1:1
E 85 technical catalogue
01.2011 4.15
curtain wall system E 85
sash for thermo-break projected window
18.9
20
E 85210
49.5
sash E 85210
13
30.6
extruded al. joint corner bracket 54 462 RAL 9005 19.2
12.8 6.4
16.5
E 85614
4.4
11 23 20 17.1 7.9
27.9
21.5
glass support E 85615
2
sash for thermo-break parallel opening window
E 85211
49.5
12
sash E 85210
30.6
4.6
E 85615
9
15
scale 1:1
E 85 technical catalogue
01.2011 4.16
curtain wall system E 85
sash profile for projected window
57.8
22.8 40.8 17
33.6 24.2
32
E 85400
scale 1:1
E 85 technical catalogue
01.2011 4.17
curtain wall system E85
pressure plates
5
26. E 85706
10.5
E 85703
E 85700 30°
7.5°
25.9
35.9
10.2
14
47.6
70.7
165° 120°
97
E 85707
.9
37.5
E 85701 36
15.8 E 85704
44
°
10.2
7.4
28.2
15°
46.4
14
14
80.8 105°
150° 110.2
E 85708
E 85705
41.6 2 1 .2
31.6
22.5°
45°
.2
47
53.8
13.4
23.6
14
E 85745
10.2
135°
89.8
47.6 90°
14
119.2
scale 1:1
E 85 technical catalogue
01.2011 4.18
curtain wall system E 85
cover caps
7.5
18
E 85721
10.5
50
∅4
25
40
1.3 E 85722
15
50
∅8
129
160
69
100
∅4 ∅4
1.4 E 85723 1.4 E 85724
47.4 47.4
16.3
1.4 1.4
31
31
50 50
scale 1:1
E 85 technical catalogue
01.2011 4.19
curtain wall system E85
cover caps
47
13.8 E 85751
E 85711 E 85716 E 85718
4.9
12
28.9
50 16.8 14.4 16.8
E 85750
45.4
10.2
60
47.4
E 85712 47.4
16.3
48
1.5
15
24.3
50 7.1 10 7.1
50
5.9
5
E 85719
47.4
E 85713
6.3
165
12.5 25 12.5
20
7.2 5.1
10.5
12.3
E 85727
E 85709
50
17.4 15.2 17.4
50
47.4
E 85714
11.3
25
70.4
E 85730
12
50
100
50
50
47.4
E 85715
47.4
16.3
16.3
E 85720 E 85702
1.5
30
25
5.5
47.4
50
50
50 50
scale 1:1
E 85 technical catalogue
01.2011 4.20
curtain wall system E 85
cover caps & pressure plates
E 85741
18
30
1 3 .5
1 3 .5
12
42
22.5°
.2
90
46.2
°
45°
32
31.5
10.8
E 85732
32
2 0 .6
2 0 .6
21.2
22.5°
45
90
50
°
pressure plate E 85740 45° pressure plate E 85741
E 85791 inox
E 85790 inox
20
15
51 51
note: cover caps E 85790 and E 85791 have to be used with special pressure plate!
scale 1:1
E 85 technical catalogue
01.2011 4.21
curtain wall system E 85
spacers for structural glazing
14.8 E 85990
6
6.8
9.2
24
14.8
19.3
glazing clips
43.6 43.6
E 85920 E 85903
8.6
5
5
10
16
11
9.3
7.3
9
33 501 33 879
22
4
8.9
33 881
10 12
scale 1:1
E 85 technical catalogue
01.2011 4.22
curtain wall system E 85
transom connectors
∅4
transom connector E 85908
45.6
45.6
E 85906
E 85907
40 45.7
42.6
10
E 85908
E 85994
43.2 6.5
E 85905
E 85904
scale 1:1
E 85 technical catalogue
01.2011 4.23
curtain wall system E 85
inserts
45.2
12.6
4
∅6.
12.6
4
∅6.
38.2
18.4
E 85951
mullion E 85101
7.2
38.4
E 85952
mullion E 85102
58.2
7.2
143.7
123.9
58.4
E 85953
mullion E 85103
7.2
78.2
78.4
E 85954
mullion E 85104
7.2
98.2
mullion E 85106
20
108.4
E 85956
E 85955
mullion E 85105
128.2
7.2
7.2
45.2 44.2
scale 1:1
E 85 technical catalogue
01.2011 4.24
curtain wall system E 85
inserts
12.6
12.6
4
∅6. 4
∅6.
20 20
154.7
163.7
134.9
143.9
E 85958
mullion E 85108
E 85957
mullion E 85107
7.2
7.2
43.6 43.2
scale 1:1
E 85 technical catalogue
01.2011 4.25
curtain wall system E 85
roof connectors / insert for E 85109
8.2 28.8 8.2
8
8.2
6.2 28.4 6.2
8
8.2
∅5
∅5
183.4
216
149.1
181.7
mullion E 85109
E 85960 E 85969
29.2 28.8
8.4
8
scale 1:1
45.2 40.8
E 85 technical catalogue
01.2011 4.26
curtain wall system E 85
inserts for half mullions
6.8
∅6.4
31.9
18.3
mullion E 85152
E 85972
6.8
38.3
mullion E 85153
51.9
E 85973
6.8
58.3
mullion E 85154
71.9
E 85974
6.8
mullion E 85155
88.3
101.9
E 85975
6.8
15.5
scale 1:1
E 85 technical catalogue
01.2011 4.27
curtain wall system E 85
reinforcement for transoms
E 85802
E 85801
156
111
transom E 85357
transom E 85306
45.4 45.4
scale 1:1
E 85 technical catalogue
01.2011 4.28
curtain wall system E 85
spacers
°
37.5
14.1
E 85640 7.5° E 85650 E 85654
7.5
7.2
6
6
10 10 10
E 8611
E 85651
15°
10
8.6
45°
6.2
17.1
E 85655
8.5
10 10
10
E 85641
22.5°
E 85652
12
10.1
6.5
10 10
E 85642
30°
18
E 85653
11.9
6.9
10 10
15.5
15.3
32
40.3
E 85911
44.2
23.9
23
R3
24.4
5
7.2
E 85966
9.6 10.4 9.6
scale 1:1
E 85 technical catalogue
01.2011 4.29
curtain wall system E 85
2nd level glazing supports 3rd level glazing supports
44.9
6.3 38.6 29.8
3.3
a = 32 a = 26.5
17.2
E 85902 E 85912
9.7
48.9
6.3 42.6 33.3
3.3
a = 36 a = 30
17.2
E 85916 E 85917
9.7
54.9
6.3 48.6
39.8
a = 42 3.3
a = 36.5
17.2
E 85910 E 85914
9.7
51.5
36
E 85803 E 85804
44.4
27.6
15.6
15.6
E 85805
accsessory utility lenght loadbearing
code
code a capacity
15.6
E 85 technical catalogue
01.2011 4.30
curtain wall system E 85
wall attachment profiles supplementary profile for holding
sealing membrane
46 28
150°
60°
20 E 85610
7.5
3
37.5
10.6
40
20.8
29.6
E 85621
2.5
74
10
13.5
E 85611
24.5
14.5
11
46 24 5 38
43
37.5
33 10
40
10
13.5
E 85612
E 85620
2.5
24.5
14.5
70 11
5 38
43
spacers for etalbond structural glazing
E 85291
E 85290 25.1
21.1 7
5.7
9.3
11.4
15
19
19
18.7
23
5.7
12
8
12.1
7
scale 1:1
E 85 technical catalogue
01.2011 4.31
COVER CAP
SECTIONS DETAILS
curtain wall system E 85
mullion with 2nd level transom
50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713
pressure plate E 85700
5
gasket 130 500
15
6 5
min 6
28
16
6
10
10
gasket 76 651
flange 76 674
190
5 5 tapping screw
DIN 7981 ST4.8x19-C-H
89
3 3
15 10 10 15
130
18 20 18
fixing part 71 113
transom E 85304
6
mullion E 85104
41
50
E85CP5.1
scale 3/4
E 85 technical catalogue
01.2011 5.1
curtain wall system E 85
transom 2nd level drainage
cover cap E 85712
pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 470
flange 76 674
min 6
15
10
56.3
50
50
10
5
15
fixing part 71 113
transom E 85304
PVC spacer 9020
5 15 5 6 16 6 10 89 41
25 28 10 130
mullion E 85104
note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
E85CP5.2
scale 3/4
E 85 technical catalogue
01.2011 5.2
curtain wall system E 85
transom 2nd level drainage with supplementary transom
cover cap E 85712
pressure plate E 85700
gasket 130 500
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 470
min 6
tapping screw
DIN 7981 ST4.8x19-C-H
15
10
50
58
10
tapping screw
15
DIN 7981 ST4.8x19-C-H
thermal insulation spacer 80 172
PVC spacer 9020
5 15 5 6 16 6 10 109 21
25 28 10 130
mullion E 85104
note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
E85CP5.3
scale 3/4
E 85 technical catalogue
01.2011 5.3
curtain wall system E 85
transom 3rd level drainage
56.3
50
50
10
5
15
flange 76 664
fixing part 71 113
transom E 85354
silicone flange 76 680 behind
thermal insulation spacer 80 172
PVC spacer 9020
mullion E 85104
5 15 5 28 4 95 41
25 6 16 6 10 130
note:
E85CP5.4
in case of 3rd level drainage, it is obligatory to use butyl seal tape in both directions.
scale 3/4
E 85 technical catalogue
01.2011 5.4
curtain wall system E 85
projected thermo-break window
structural seal 6 mm
25
norton tape 6x6.4 mm
6
6
6
28
16
16
31
16
6
6
6
7
10
7
mullion E 85104
operating rod E 2308
striker 255 602
striker 255 603
E85CP5.5
50
scale 3/4
E 85 technical catalogue
01.2011 5.5
curtain wall system E 85
projected thermo-break window with 2nd level transom
28
20 5 6 16 6 7 56 77
20
operating rod E 2308
structural seal 6 mm self-drilling screw
8 DIN 7981 ST4.8x32-M-Z
gasket 130 131 gasket 130 180
33
frame E 85410
gasket 130 706
9
2
45.8
36
6
50
31 7
5 15 5 6 16 6 10 89 41
20 5 28 10 130
E85CP5.6
scale 3/4
E 85 technical catalogue
01.2011 5.6
curtain wall system E 85
projected thermo-break window with 3rd level transom
28
20 5 6 16 6 7 56 77
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 131 gasket 130 180
33
frame E 85410
9
2
45.8
36
50
31
1
gasket 130 500 thermal insulation spacer 80 172
5 15 5 6 16 6 10 89 41
E85CP5.7
scale 3/4
E 85 technical catalogue
01.2011 5.7
curtain wall system E 85
parallel opening thermo-break window
25
norton tape 6x6.4 mm
6
6
6
28
16
16
31
16
6
6
6
7
10
7
3
gasket 130 413 18 20 18
transom E 85304
77
mullion E 85104
41
E85CP5.8
50
scale 3/4
E 85 technical catalogue
01.2011 5.8
curtain wall system E 85
parallel opening thermo-break window with 2nd level transom
28
20 5 6 16 6 7 56 77
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8 gasket 130 180
gasket 130 131
33
transom E 85304
14.4
2
45.8
36
6
50
31 7
5 15 5 6 16 6 10 89 41
20 5 28 10 130
E85CP5.9
scale 3/4
E 85 technical catalogue
01.2011 5.9
curtain wall system E 85
parallel opening thermo-break window with 3rd level transom
28
20 5 6 16 6 7 56 77
20
gasket 130 461
norton tape 6x6.4 mm
operating rod E 2308
structural seal 6 mm self drilling screw
DIN 7981 ST4.8x32-M-Z
gasket 130 131 8 gasket 130 180
33
transom E 85304
14.4
2
45.8
36
50
31
1
gasket 130 500 thermal insulation spacer 80 172
5 15 5 6 16 6 10 89 41
E85CP5.10
scale 3/4
E 85 technical catalogue
01.2011 5.10
curtain wall system E 85
projected window
tapping screw
DIN 7981 ST5.5x45-C-H cover cap E 85713
thermal insulation spacer 80 172 50
1 1
thermal insulation spacer 80 177 25 10 15 pressure plate E 85700
structural seal 6 mm butyl seal 133 553
norton tape 6x6.4 mm
25
37.3 10
gasket 130 500
20
6
26
14
28
16
26
4
6
6
4
12
10
gasket 130 175
gasket 130 470
profile 8902
39.9
spacer E 85640
sash E 85200
14.3 51
gasket 130 180 2
65.3 3 3
frame E 85400
46.9
15 10 10 15
gasket 130 458
18 20 18
gasket 130 409
transom E 85304
mullion E 85104
41
E85CP5.11
scale 3/4
E 85 technical catalogue
01.2011 5.11
curtain wall system E 85
projected window with 2nd level transom
14.3
4
51
spacer E 85640
50
scale 3/4
E 85 technical catalogue
01.2011 5.12
curtain wall system E 85
projected window with 3rd level transom
14.3
4
51
gasket 130 500
2
5 15 5 6 16 6 4 6 89 41
20 5 28 10 130
E85CP5.13
scale 3/4
E 85 technical catalogue
01.2011 5.13
curtain wall system E 85
window in curtain wall
thermal insulation spacer 80 172
102 50
1
41.5 5 55.5 14 11 10 15
gasket 130 470 cover cap E 85713
additional profile E 85641
pressure plate E 85700
gasket 130 152
16.5
6
9.5
28
16
12
6
sash E 2482
gasket 130 131
100.5
frame E 2424
transom E 85304
mullion E 85104
E85CP5.14
scale 3/4
E 85 technical catalogue
01.2011 5.14
curtain wall system E 85
window in curtain wall with 2nd level transom
28
20 5 8 6 16 6 39
gasket 130 177
gasket 130 411 glazing bead 5380
21
42.5
53.5
103
103
gasket 130 161
sash E 2482
55.5
frame E 2424
26.5
59.5
50
thermal insulation spacer 80 172
transom E 85304
15 5 28 10 gasket 130 470
mullion E 85104
E85CP5.15
scale 3/4
E 85 technical catalogue
01.2011 5.15
curtain wall system E 85
window in curtain wall with 3rd level transom
28
20 5 8 6 16 6 39
gasket 130 177
gasket 130 411 glazing bead 5380
21
41.5
53.5
103
102
sash E 2482
55.5
frame E 2424
26.5
59.5
50
thermal insulation spacer 80 172
transom E 85354
mullion E 85104
scale 3/4
E 85 technical catalogue
01.2011 5.16
curtain wall system E 85
door in curtain wall
28
16
6
10
31.6
21 46 5 60.9
2
134.9
glazing bead E 5307 gasket 130 413
sash E 2443
gasket 130 152
frame E 2445
108.4
transom E 85304
mullion E 85104
E85CP5.17
scale 3/4
E 85 technical catalogue
01.2011 5.17
curtain wall system E 85
door in curtain wall with 2nd level transom
tapping screw
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 172
glazing shim 71 183
15 5 28 10 transom E 85304
15
10
50
6.7
18.3
2
mullion E 85104
60.9
frame E 2445
5
134.9
134.9
5
46
sash E 2443
8 6 16 6 31.6
E85CP5.18
E 85 technical catalogue
01.2011 5.18
curtain wall system E 85
door in curtain wall with 3rd level transom
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 474
thermal insulation spacer 80 172
glazing shim 71 185
15 5 28 10 transom E 85354
15
10
50
6.7
18.3
2
12.1 28 10 67.4 41
35.9
frame E 2445
5
mullion E 85104
134.9
134.9
5
46
sash E 2443
8 6 16 6 31.6
E85CP5.19
E 85 technical catalogue
01.2011 5.19
curtain wall system E 85
split mullion
50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713
pressure plate E 85700
5
gasket 130 500
15
6 5
min 6
28
16
6
10
10
flange 76 674
tapping screw
DIN 7981 ST4.8x19-C-H
gasket 130 198
89
transom E 85304
21
self-drilling screw
DIN 7981 ST3.5x18-M-Z
supplementary profile E 85151
22.5 5 22.5
gasket 130 199
50
E85CP5.20
scale 3/4
E 85 technical catalogue
01.2011 5.20
curtain wall system E 85
mullion for substructure
50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713
pressure plate E 85700
5
25
gasket 130 500
15
5
6
28
16
6
10
thermal insulation spacer 80 172
103
29
gasket 76 651
transom E 85301
flange 76 671
tapping screw
DIN 7981 ST4.8x19-C-H
36
mullion E 85120
cap E 19641
7.5
nut cheese head screw
DIN 934-A2-70 DIN 931 M8x30-A2-70
washer spring washer
DIN 125 ∅ 8-A2-70 DIN 127 ∅8-A2-70
PVC
bush ∅10x2
E85CP5.21
scale 3/4
E 85 technical catalogue
01.2011 5.21
curtain wall system E 85
outer corner 90°
90º
etalbond
hard insulation 20 mm
4 seal 4 mm
self drilling screw
DIN 7981 ST3.5x18-M-Z
aluminium sheet 2 mm
1
4.33
25
hard insulation 20 mm
soft insulation 31.5 mm
75
1
4.33
31.5 4 20 4 25
mullion E 85130
blind rivet
10
flange 76 674
gasket 076 651
gasket 130 457
1 transom E 85304
E85CP5.22
90 7 6 16 6 20 5
28 25
scale 3/4
E 85 technical catalogue
01.2011 5.22
curtain wall system E 85
outer corner 90°
90º
94 10 6
100
seal 10 mm
silicone coating
soft insulation 40 mm
etalbond
min 6
min 6
100
110
mullion E 85130
tapping screw
DIN 7981 ST4.8x19-C-H
gasket 130 457
transom E 85304
1
90 7 6 16 6 5 15
28 5 15
note:
it is necessary to calculate
E85CP5.23
scale 3/4
E 85 technical catalogue
01.2011 5.23
curtain wall system E 85
outer corner 90°
90º
etalbond
hard insulation
thermal insulation spacer 80 174 50
suppl. mullion profile E 85143 15 10 15 10 20.4 25
gasket 130 457
spacer E 85655 35.4
25
20.4
35.4
10
tapping screw
15
DIN 7981 ST5.5x45-C-H
50
10
15
transom E 85354 28
E85CP5.24
89 7 6 16 6
scale 3/4
E 85 technical catalogue
01.2011 5.24
curtain wall system E 85
outer corner 90°
90°
etalbond
hard insulation 20 mm
4
seal 4 mm
self-drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.36
50 165
1 tapping screw
15 10 15 10 DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
5
etalbond
6 5
28
16
6
7
10 152 4 20 4
28
gasket 130 457
hard insulation 40 mm
89
165
1
4.36
self-drilling screw
DIN 7981 ST4.8x19-M-Z
240
L-profile section 4065
blind rivet
DIN 7337 A4.8x8-A
41
10
15
50
50
10
15
1
E85CP5.25
not to scale
E 85 technical catalogue
01.2011 5.25
curtain wall system E 85
outer corner 90°
90°
max 500
tapping screw
DIN 7981 ST5.5x45-C-H 22 10 6 5 15
5
seal 10 mm
15
5
6 5
min 6
23
28
16
6
7
7
10 28
seal 10 mm
gasket 130 457
welded seam 3 mm
89
130
flange 76 674
max 500
transom E 85304
mullion E 85104
41
note:
the glass thickness should be
E85CP5.26
not to scale
E 85 technical catalogue
01.2011 5.26
curtain wall system E 85
inner corner 90°
90°
gasket 130 500
pressure plate E 85700
50
tapping screw
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174 min 5
min 5
gasket 130 457
3
5
gasket 130 457
30
25
15
30 blind rivet
73
58
65
hard insulation 20 mm
28
16
etalbond
6
7
73
154
151
58
65 130
190
welded seam 3 mm
89
flange 76 674
mullion E 85104
130
130
transom E 85304
50 3 151
154
41
E85CP5.27
not to scale
E 85 technical catalogue
01.2011 5.27
curtain wall system E 85
inner corner 90°
90°
gasket 130 500
cover cap E 85731
16
6
15 130
7
145
suppl. mullion profile E 85142
thermal insulation spacer 80 172
tapping screw
DIN 7981 ST5.5x45-C-H
tapping screw
89
DIN 7981 ST5.5x16-C-H
130
41
E85CP5.28
scale 3/4
E 85 technical catalogue
01.2011 5.28
curtain wall system E 85
outer corner 45° - 150°
32 45º-150º
etalbond
soft insulation 24 mm
4
seal 4 mm
self drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.41
thermal insulation spacer 80 174
4
6
1
gasket 130 457 4.41
28
16
24
32
50
6
32
4
self drilling screw
DIN 7981 ST4.8x19-M-Z
L-profile section 4010 Aluminum
aluminium sheet 2 mm
supplementary profile E 85150
mullion E 85153
4 5°
-150
°
E85CP5.29
scale 3/4
E 85 technical catalogue
01.2011 5.29
curtain wall system E 85
inner corner 135°
135°
tapping screw
DIN 7981 ST5.5x38-C-H
cover cap E 85732
pressure plate E 85741
gasket 130 500
21.6
26.6
6 5
28
16
6
7
7
gasket 130 457
flange 76 674
5
thermal insulation spacer 80 174
tapping screw
DIN 7981 ST4.8x19-C-H
89
90
mullion E 85135
135°
1
transom E 85304
E85CP5.30
scale 3/4
E 85 technical catalogue
01.2011 5.30
curtain wall system E 85
outer corner 30°-90°
30º-90º
L-profile section 4134
etalbond
soft insulation
30°-90°
cover cap E 85713
tapping screw
DIN 7981 ST5.5x38-C-H
pressure plate E 85700
butyl seal 133 553
gasket 130 500
butyl seal
self drilling screw
DIN 7981 ST4.8x19-M-Z
6
16
28
6
7
15
9.5
transom E 85300
tapping screw
DIN 7981 ST5.5x32-C-H
90
mullion E 85102
E85CP5.31
scale 3/4
E 85 technical catalogue
01.2011 5.31
curtain wall system E 85
polygonal facade with outer angle max 5°
50 tapping screw
1 1 DIN 7981 ST5.5x45-C-H
15 10 10 15 cover cap E 85713
pressure plate E 85700
5°
gasket 130 500
5 6
16
28
6 4
35
flange 76 661
3 15 10 10 15 3 transom E 85351
mullion E 85101
gasket 130 500
6 5
28
16
4 6
thermal insulation spacer 80 172
35
flange 76 661
transom E 85351
3 15 10 10 15 3
mullion E 85101
E85CP5.32
scale 3/4
E 85 technical catalogue
01.2011 5.32
curtain wall system E 85
outer angles 0°~15°
tapping screw
DIN 7981 ST5.5x55-C-H
cover cap E 85711
pressure plate E 85703
5 6
16
28
6 4
4
tapping screw
outer angles 7.5°~22.5° DIN 7981 ST5.5x55-C-H
cover cap E 85711
pressure plate E 85704
butyl seal 133 553
7.5°-22.5°
gasket 130 500
12
17
5 6
16
28
6 4
4
5 10 5
gasket 130 474
spacer E 85651
scale 3/4
E 85 technical catalogue
01.2011 5.33
curtain wall system E 85
outer angles 15°~30°
tapping screw
DIN 7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85705
gasket 130 500
5
6
16
28
6 4
5 10 5
4
tapping screw
DIN 7981 ST5.5x60-C-H
outer angles 22.5°~37.5° cover cap E 85711
gasket 130 500
°
spacer E 85653
17
5
6
16
28
6
4
4
5 10 5
E85CP5.34
scale 3/4
E 85 technical catalogue
01.2011 5.34
curtain wall system E 85
outer angles 30°~45°
tapping screw
DIN 7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85707
spacer E 85654
12
17
5
6
16
28
6
4
5 10 5
4
gasket 130 500
gasket 130 474
spacer E 85655`
12
5
17
6
16
28
6
4
5 10 5
4
E85CP5.35
scale 3/4
E 85 technical catalogue
01.2011 5.35
curtain wall system E 85
roof connector
tapping screw
DIN 7981 ST5.5x68-C-H
cover cap E 85711
spacer E 85653
19
5
6
0.3
14
5
28.
35
4
44
4
transom E 85305
mullion connector E 85960 below
mullion E 85104
E85CP5.36
scale 3/4
E 85 technical catalogue
01.2011 5.36
01.2011
scale 1:2
50 255 50
E 85 technical catalogue
1 1 tapping screw 1 1
15 10 10 15 DIN 7981 ST5.5x45-C-H 15 10 10 15
cover cap E 85713
pressure plate E 85700
15
gasket 130 500
curtain wall system
6 5
16
28
6
10
10
gasket 130 470 transom E 85305
thermal insulation spacer 80 172 mullion E 85104
gasket 76 651
43
gypsum board
flange 76 674
soft insulation 50 mm
5.37
connection between curtain wall and partition wall
12.5
E 85
E85CP5.37
01.2011
scale 1:2
50 255 50
1 1 tapping screw 1 1
15 10 10 15 DIN 7981 ST5.5x45-C-H 15 10 10 15
cover cap E 85713
thermal insulation spacer 80 177
delatation
pressure plate E 85700
sheet aluminium 2 mm
E 85 technical catalogue
butyl seal 133 553 membrane 2 mm
gasket 130 500 insulation soft
2
2
24
curtain wall system
10
transom E 85305 gasket 130 470
thermal insulation spacer 80 172
gasket 76 651
flange 76 674
mullion E 85104
130
208
5.38
bracket 71090
40
E 85
E85CP5.38
curtain wall system E 85
connection with backing wall
concrete wall
membrane 2 mm
hard insulation 50 mm
plaster
seal 2 mm
etalbond
butyl seal 133 553
15
20
6 5
1
4
28
16
17
6
10
10
gasket 130 470
thermal insulation spacer 80 172
89
additional profile E 85620
130
41
E85CP5.39
scale 3/4
E 85 technical catalogue
01.2011 5.39
curtain wall system E 85
connection with rainscreen cladding system BRAVO
50
28
gasket 130 470
membrane 1 mm
gypsum board
E85CP5.40
scale 3/4
E 85 technical catalogue
01.2011 5.40
curtain wall system E 85
connection with rainscreen cladding system Forte
8 50
stone
25
30
5
28
34
10
forte system by ETEM
43
49
hard insulation
membrane
soft insulation
51
scale 3/4
E 85 technical catalogue
01.2011 5.41
curtain wall system E 85
conservatories vertical section with 2nd level transom
135°
cover cap E 85730
thermal insulation spacer 80 174
20
tapping screw
DIN 7981 ST5.5x38-C-H
5
pressure plate E 85701
6
14
etalbond
7
hard insulation 17 mm
membrane 1 mm
29
gasket 130 457
glazing shim 71 184
110
transom E 85320
gasket 130 199
32
135°
tapping screw
32
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
accessory 74 674
gasket 130 457
machine cutting
for transom slot
E85CP5.42
scale 3/4
E 85 technical catalogue
01.2011 5.42
curtain wall system E 85
conservatories vertical section with 3rd level transom
90°-150°
20
5
cover cap E 85730
28
.4
thermal insulation spacer 80 174
14
tapping screw
8.4
DIN 7981 ST5.5x38-C-H
3
pressure plate E 85701
butyl seal 133 553
55
etalbond
hard insulation 30 mm gasket 130 473
membrane 1 mm transom E 85370
suppl. profile E 85670
tapping screw
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
gasket 130 473
accessory 74 674
E85CP5.43
20 5 28 9
scale 3/4
E 85 technical catalogue
01.2011 5.43
curtain wall system E 85
conservatories vertical section
90°-150°
pressure plate E 85701
20
cover cap E 85730
5
self-drilling screw
6
DIN 7981 ST4.8x19-M-Z
28 . 4
14
2
113.
8.4
7
thermal insulation spacer 80 174
20
gasket 130 457
tapping screw
DIN 7981 ST5.5x38-C-H
89
mullion is trimmed
44
etalbond .7
100
hard insulation 26 mm
113.2
41
membrane 1 mm
etalbond
cut for membrane in mullion
thermal insulation spacer 80 184
F profile 31064
67.4
tapping screw
DIN 7981 ST4.2x25-C-H
5
tapping screw
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
gasket 130 457
20 5 6 16 6 7 89 41
25 28 7 130
E85CP5.44
not to scale
E 85 technical catalogue
01.2011 5.44
curtain wall system E 85
conservatories vertical section
115 °
pressure plate E 85701
20
cover cap E 85730
5
6
13 1
14
117.2
8.4
7
thermal insulation spacer 80 174
tapping screw
13.9 DIN 7981 ST5.5x38-C-H
gasket 130 457
glazing shim 71 184
89
10
14.4
10
seal 10 mm
41
96.8
82.4
20 5 6 16 6 7 89 41
°
115
15
10
50
10
tapping screw
15
DIN 7981 ST5.5x38-C-H
thermal insulation spacer 80 174
gasket 130 457
20 5 6 16 6 7 89 41
25 28 7 130
note:
the glass thickness should be
E85CP5.45
scale 3/4
E 85 technical catalogue
01.2011 5.45
curtain wall system E 85
conservatories vertical section
20
5
tapping screw
6
DIN 7981 ST4.2x32-C-H
14
8.4
soft insulation 40 mm
6.7
.8
166
47.7
89
10
seal 10 mm
silicone coating
etalbond
96.4
°
115
note: 20 5 6 16 6 7 89 41
the glass thickness
E85CP5.46
E 85 technical catalogue
01.2011 5.46
curtain wall system E 85
slope > 25°
tapping screw
DIN 7981 ST5.5x45-C-H
butyl seal 133 553
cover cap E 85730
pressure plate E 85701
gasket 130 500
8
12
>25°
20
5
6
14
0.35
28.3
4 4
5
10
scale 3/4
E 85 technical catalogue
01.2011 5.47
curtain wall system E 85
slope > 15°
2
6
5 6
>15°
14
0.35
28.35
4 4
10
mullion E 85104
E85CP5.48
scale 3/4
E 85 technical catalogue
01.2011 5.48
curtain wall system E 85
slope > 7°
2
5 6
1.2
14 4 4
28.35
0.35
>7°
10
mullion E 85104
E85CP5.49
scale 3/4
E 85 technical catalogue
01.2011 5.49
curtain wall system E 85
connection with backing wall
1.5 1
aluminium sheet 1.5 mm 61.5
seal 5 mm
hard insulation 50 mm
aluminium sheet 1.5 mm
4.5
5
membrane 1 mm
46.5
10
10
hard insulation 25 mm
membrane 1 mm
self-drilling screw
DIN 7981 ST4.2x16-O-Z
1.5
25
131.5
1
1.5
89
bracket E 85913
reinforced concrete
E85CP5.50
41
40
not to scale
E 85 technical catalogue
01.2011 5.50
curtain wall system E 85
bottom finishing
water drainage
gasket 130 500
thermal insulation spacer 80 177
additional profile E 85612 24 38
bracket 71 050
membrane
hard insulation
30
plaster
hard insulation 50 mm
E85CP5.51
scale 3/4
E 85 technical catalogue
01.2011 5.51
curtain wall system E 85
bottom finishing
20 5 28 10 109 21
water drainage
vapor barrier
membrane
aluninium sheet
ground tiles
E85CP5.52
scale 1:2
E 85 technical catalogue
01.2011 5.52
curtain wall system E 85
finishing to suspended ceiling
water drainage
28
20 5 6 16 6 10
mullion E 85104
transom E 85306
gasket 130 470
tapping screw
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 172
thermal insulation spacer 80 177
additional profile E 85612
cut for membrane in mullion
membrane
concrete slab
hard insulation 60 mm
tube
aluminum 60x30x2
perforation
self-drilling screw
DIN 7981 ST5.5x19-M-Z
not to scale
E 85 technical catalogue
01.2011 5.53
curtain wall system E 85
finishing of plaster ceiling
L-profile section 4065
self-drilling screw
DIN 7981 ST4.8x19-M-Z
30
90
60
etalbond
membrane
membrane additional profile E 85612
hard insulation 32 mm thermal insulation spacer 80 177
4 24 10 33 76
50
bracket 71 050
transom E 85305
20 5 6 16 6 10 mullion E 85104
25 28 10 gasket 130 470
thermal insulation spacer 80 172
E85CP5.54
scale 3/4
E 85 technical catalogue
01.2011 5.54
curtain wall system E 85
outer angle vertical section
25 28 7 130
20 5 6 16 6 7 89 41
gasket 130 457
thermal insulation spacer 80 174
tapping screw
DIN 7981 ST5.5x45-C-H
15
10
50
10
15
20 5 4 20 4 96
hard insulation 20 mm
etalbond
mullion E 85104
E85CP5.55
not to scale
E 85 technical catalogue
01.2011 5.55
curtain wall system E 85
inner angle vertical section
41
130
41
89
7
7
6
28
89
16
5
6
25
7
6
15
16
10
10
6
50
5
15
20
86.
6
86.
6
mullion E 85104
86.6
86.6
tapping screw
15
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 174
gasket 130 457
20 5 6 16 6 7 89 41
E85CP5.56
25 28 7 130
not to scale
E 85 technical catalogue
01.2011 5.56
01.2011
scale 1:2
E 85 technical catalogue
profile E 8656
curtain wall system
profile E 8863
glass spandrel panel in brustung zone
3M tape
5.57
sheet steel 2 mm
soft insulation
bracket 71 072
steel sheet 2 mm
perforation
0.38
25 min 30
4 4
mullion E 85104
transom E 85305
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 500
thermal insulation spacer 80 172
E85
E85CP5.57
01.2011
scale 1:2
E 85 technical catalogue
20 5 28 10 109 21
curtain wall system
thermal insulation spacer 80 172
gasket 130 500
50
tapping screw
DIN 7981 ST5.5x45-C-H
15
aluminum sheet 1 mm
membrane
ceramic tiles in brustung zone rainscreen cladding system VARIO
soft insulation
ceramic tile
Agrob Buchtal
adaptor
mullion E 85104
5.58
transom E 85305
membrane
15
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 500
thermal insulation spacer 80 172
E85
E85CP5.58
01.2011
scale 1:2
E 85 technical catalogue
curtain wall system
transom E 85305
gasket 130 470
etalbond spandrel panel in brustung zone
5.59
butyl seal 133 553
gasket 130 480
min 5
tapping screw
DIN 7981 ST5.5x45-C-H
thermal insulation spacer 80 172
thermal insulation spacer 80 177 2 2
20 123
4 2
151
aluminium sheet 2 mm
etalbond
steel sheet 2 mm
soft insulation
130
bracket 71 072
steel sheet 2 mm
mullion E 85104
transom E 85305
thermal insulation spacer 80 177
gasket 130 500
gasket 130 480
thermal insulation spacer 80 172
E85CP5.59
01.2011
scale 1:2
E 85 technical catalogue
curtain wall system
soft insulation
connection with rainscreen system Forte
hard insulation
membrane
thermal insulation spacer 80 184
8
thermal insulation spacer 80 174
pressure plate E 85700
50
cover cap E 85720 transom E 85304
bracket 71 050
transom E 85300
25 5 28 10 15
bracket 71 050
membrane
47
bracket E 85967
membrane
E85
E85CP5.60
curtain wall system E 85
usage of hidden transom on floor level
transom E 85380
self-drilling screw
DIN 7981 ST4.8x19-M-Z
steel sheet 2 mm
waterproof
gypsum board
washer DIN 440
bracket 71 072
steel sheet 2 mm
25 28
2
20 5 6 16 6 10 min 30 12.5 50 21
mullion E 85104
transom E 85305
gasket 130 470
glazing shim 71 183
butyl seal 133 553
tapping screw
DIN 7981 ST5.5x45-C-H
gasket 130 500
thermal insulation spacer 80 172
E85CP5.61
not to scale
E 85 technical catalogue
01.2011 5.61
curtain wall system E 85
upper finishing with etalbond 10
min 6
1
4.23
1
4.23
etalbond
membrane
thermal insulation spacer 80 172
soft insulation
gypsum board
min 30
bracket 71 270
transom E 85305
thermal insulation spacer 80 172
E85CP5.62
tapping screw
DIN 7981 ST5.5x45-C-H
not to scale
E 85 technical catalogue
01.2011 5.62
STRUCTURAL
GLAZING
SECTIONS DETAILS
curtain wall system E 85
mullion with 2nd level transom
silicone seal
silicone gasket 130 705
tapping screw
DIN 7982 ST5.5x25-C-H
15 20 15
10 10 glazing clip 71 116
spacer E 85990
6
32
20
6
6
gasket 76 651
flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89
3 3
15 10 10 15
130
18 20 18
fixing part 71 113
transom E 85304
6
mullion E 85104
41
50
E85SG6.1
scale 3/4
E 85 technical catalogue
01.2011 6.1
curtain wall system E 85
transom 2nd level drainage
spacer E 85990
glazing clip 71 116
gasket 130 463
flange 76 674 mullion E 85104
glazing shim 71 184
15
10
56.3
20
50
10
tapping screw
5
DIN 7982 ST5.5x25-C-H
15
fixing part 71 113
transom E 85304
gasket 076 651 behind
6 20 6 6 89 41
32 6 130
note:
E85SG6.2
E 85 technical catalogue
01.2011 6.2
curtain wall system E 85
mullion with 2nd level transom
silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
15 20 15 DIN 7982 ST5.5x25-C-H
10 10 glazing clip 71 130
spacer 33 879
min 6
3M tape
6
min 6
28
16
6
12
12
flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89
3 3
15 10 10 15
130
18 20 18
fixing part 71 113
transom E 85304
6
mullion E 85104
41
50
E85SG6.3
scale 3/4
E 85 technical catalogue
01.2011 6.3
curtain wall system E 85
transom 2nd level drainage
spacer 33 879
glazing clip 71 130
gasket 130 480
flange 76 674
glazing shim 71 184
15
56.3
20
50
10
tapping screw
5
DIN 7981 ST5.5x25-C-H
15
min 6
fixing part 71 113
transom E 85304
gasket 076 651 behind
6 16 6 12 89 41
28 12 130
E85SG6.4
scale 3/4
E 85 technical catalogue
01.2011 6.4
curtain wall system E 85
transom 3rd level drainage
spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185
flange 76 664
15
56.3
20
50
10
tapping screw
5
DIN 7981 ST5.5x25-C-H
15
min 6
fixing part 71 113
transom E 85354
6 16 6 12 89 41
28 12 130
E85SG6.5
scale 3/4
E 85 technical catalogue
01.2011 6.5
curtain wall system E 85
projected thermo-break window
6
6
28
16
16
6
6
7
9.2
16 21 18
transom E 85304
77
mullion E 85104
41
50
E85SG6.6
scale 3/4
E 85 technical catalogue
01.2011 6.6
curtain wall system E 85
projected thermo-break window with 2nd level transom
6 16 6 7 56 38.2
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 479 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5
38.5
frame E 85410
gasket 130 707
transom E 85304
1
16
14
2
7.9
9.2
33.3
6
1.6
20.8
50
min 6
fixing part 71 113
transom E 85304
gasket 076 651 behind
gasket 130 480
silicone gasket 130 705
silicone seal
mullion E 85104
89 41
130
E85SG6.7
scale 3/4
E 85 technical catalogue
01.2011 6.7
curtain wall system E 85
projected thermo-break window with 3rd level transom
6 16 6 7 56 38.2
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 473 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5
38.5
frame E 85410
gasket 130 707
transom E 85354
1
16
14
2
7.9
3
33.3
6
1.6
20.8
50
min 6
flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
silicone gasket 130 705
silicone seal
mullion E 85104
6 16 6 6 6 89 41
28 12 130
E85SG6.8
scale 3/4
E 85 technical catalogue
01.2011 6.8
curtain wall system E 85
parallel opening thermo-break window
silicone seal
silicone gasket 130 705
glass support E 85614
80 171 / 80183
gasket 130 707 tapping screw
33.3 DIN 7981 ST5.5x25-C-H
gasket 130 479
1 2 1.6 glazing clip 71 130
structural seal 6 mm 55.5 7.9 20.8
norton tape 6x6.4 mm spacer 33 879 + 3M tape
6
6
6
28
16
16
6
6
7
9.2
mullion E 85104
41
E85SG6.9
50
scale 3/4
E 85 technical catalogue
01.2011 6.9
curtain wall system E 85
parallel opening thermo-break window with 2nd level transom
6 16 6 7 56 38.2
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 479 gasket 130 180
friction arm 900R/900L
glass support E 85614
55.5
38.5
frame E 85410
gasket 130 707
transom E 85304
2
16
14
7.9
9.2
33.3
6
20.8
50
80 171 / 80183
15
min 6
fixing part 71 113
flange 76 674
gasket 076 651 behind
gasket 130 480
89 41
130
E85SG6.10
scale 3/4
E 85 technical catalogue
01.2011 6.10
curtain wall system E 85
parallel opening thermo-break window with 3rd level transom
6 16 6 7 56 38.2
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 473 gasket 130 180
friction arm 900R/900L
glass support E 85614
55.5
38.5
frame E 85410
gasket 130 707
transom E 85354
1
16
14
2
7.9
3
33.3
6
1.6
20.8
80 171 / 80183
15
min 6
flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
glazing clip 71 130
silicone gasket 130 705
silicone seal
mullion E 85104
6 16 6 6 6 89 41
28 12 130
E85SG6.11
scale 3/4
E 85 technical catalogue
01.2011 6.11
curtain wall system E 85
window in curtain wall
116 36
41.5 5 69.5
gasket 130 480
additional profile E 85641 silicone gasket 130 705
gasket 130 152 thermal insulation spaser
21 15
80 171/80 183
min 6 mm *
gasket 130 161 11 10 glazing clip 71 130
gasket 130 411
6 spacer 33 879
6
8
6
28
16
11.7
28
16
6
6
12
12
12
9
15
30.5
gasket 130 177
sash E 2482
gasket 130 131
frame E 2424
6
transom E 85304
mullion E 85104
41
50
E85SG6.12
scale 3/4
E 85 technical catalogue
01.2011 6.12
curtain wall system E 85
window in curtain wall
28
8 6 16 6 9 30.5
gasket 130 177
gasket 130 411 glazing bead 5380
21
42.5
53.5
103
gasket 130 161
sash E 2482
69.5
117
min 6 mm *
glazing shim 71 184
6
11
21
50
10
5
15
min 6
scale 3/4
E 85 technical catalogue
01.2011 6.13
curtain wall system E 85
window in curtain wall
28
8 6 16 6 9 30.5
gasket 130 177
gasket 130 411 glazing bead 5380
21
42.5
53.5
103
sash E 2482
69.5
117
50
10
11.7 6
15
transom E 85354
gasket 130 463
mullion E 85104
6 16 6 6 6 89 41
E85SG6.14
28 12 130
scale 3/4
E 85 technical catalogue
01.2011 6.14
curtain wall system E 85
outer corner 90°
90º
silicone seal
silicone gasket 130 705
tapping screw
DIN 7981 ST5.5x25-C-H etalbond
glazing clip 71 130 hard insulatin
41
suppl. mullion profile E 85143
spacer E 85655
20
tapping screw
DIN 7981 ST5.5x45-C-H
transom E 85354
89 12 6 16 6
101 28
E85SG6.15
scale 3/4
E 85 technical catalogue
01.2011 6.15
curtain wall system E 85
outer corner 90° 90°
etalbond
4 hard insulation 20 mm
seal 4 mm
self-drilling screw
DIN 7981 ST3.5x18-M-Z
1
aluminium sheet 2 mm 4.93
silicone seal
silicone gasket 130 705
tapping screw
DIN 7981 ST5.5x25-C-H
glazing clip 71 130 thermal insulation spacer 80 177
spacer 33 879 + 3M tape hard insulation 20 mm
etalbond
4
6
20
16
6
4
12
gasket 130 457
hard insulation 40 mm
89
1
4.93
self drilling screw
DIN 7981 ST4.8x19-M-Z
142
220
L-profile section 4065
blind rivet
DIN 7337 A4.8x8-A
41
50
E85SG6.16
not to scale
E 85 technical catalogue
01.2011 6.16
curtain wall system E 85
inner corner 90°
90°
50
6
3
28
16
25.2
12 6
12
etalbond
gasket 130 480
25.2 130
114
111
89
welded seam 3 mm
130
130
50 111
3
41
114
transom E 85304
flange 76 674
mullion E 85104
E85SG6.17
scale 1:2
E 85 technical catalogue
01.2011 6.17
curtain wall system E 85
inner corner 90°
90°
silicone seal
silicone gasket 130 705
thermal insulation spacer
80 171/80 183
glazing clip 71 130
spacer 33 879 + 3M
12
6
28
16
6
8
15 130
14
145
suppl. mullion profile E 85142
tapping screw
DIN 7981 ST5.5x16-C-H
spacer E 85640
89
130
41
E85SG6.18
scale 3/4
E 85 technical catalogue
01.2011 6.18
curtain wall system E 85
silicone seal
polygonal facade with outer angle max 5°
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
20 DIN 7981 ST5.5x25-C-H
glazing clip 71 130
5°
6 16
28
6 5
flange 76 661
3 15 10 10 15 3 transom E 85351
mullion E 85101
silicone seal
silicone gasket 130 705
thermal insulation spaser
polygonal facade with inner angle max 5° 80 171/80 183
tapping screw
19.9 DIN 7981 ST5.5x25-C-H
6
5°
flange 76 661
transom E 85351
3 15 10 10 15 3
mullion E 85101
E85SG6.19
scale 3/4
E 85 technical catalogue
01.2011 6.19
curtain wall system E 85
conservatories vertical section
90°-150°
6
20
30.4
self-drilling screw
16
DIN 7981 ST4.8x19-M-Z
8.4
10
131
89
27
mullion is trimmed
4 4
etalbond 104
hard insulation
41
membrane 1 mm
etalbond
cut for membrane in mullion
thermal insulation spacer 80 184
4 28 43 F profile 31064
1
tapping screw
66
DIN 7981 ST4.2x25-C-H
5
20
silicone seal
silicone gasket 130 705
6 16 6 12 89 41
28 12 130
E85SG6.20
not to scale
E 85 technical catalogue
01.2011 6.20
curtain wall system E 85
conservatories vertical section
115 °
6
20
30.4
16
8.4
10
120
184
gasket 130 470
seal 10 mm
89
64 mullion connector E 85969 below
10
16
10
seal 10 mm
48
41
115
99
°
115
20
6 16 6 12 89 41
28 12 130
note:
the glass thickness should be
E85SG6.21
not to scale
E 85 technical catalogue
01.2011 6.21
curtain wall system E 85
connection with rainscreen cladding system BRAVO
100 20
etalbond
29
gypsum board
E85SG6.22
scale 3/4
E 85 technical catalogue
01.2011 6.22
curtain wall system E 85
connection with backing wall
etalbond
bravo system by ETEM
silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
DIN 7981 ST5.5x25-C-H
glazing clip 71 130
122 20 spacer 33 879
3M tape
28
16
6
membrane 1 mm
12
12
gasket 130 480
89
130
41
E85SG6.23
scale 3/4
E 85 technical catalogue
01.2011 6.23
curtain wall system E 85
bottom finishing
etalbond
bracket 71 050
concrete slab
27
30
soft insulation 60 mm
membrane
L-profile section 4065
self-drilling screw
DIN 7981 ST4.8x19-M-Z
seal 6 mm
plaster
perforation
hard insulation
E85SG6.24
scale 1:2
E 85 technical catalogue
01.2011 6.24
curtain wall system E 85
facade finishing to suspended ceiling
28 12 130
6 16 6 12 109 21
spacer 33 879
glazing clip 71 130
gasket 130 480
flange 76 651
glazing shim 71 182
steel sheet 1.5 mm
15
20
15
accessory 74 674
hard insulation
membrane
concrete slab
etalbond
self-drilling screw
DIN 7981 ST4.8x19-M-Z
perforation
L-profile section aluminum
E85SG6.25
not to scale
E 85 technical catalogue
01.2011 6.25
curtain wall system E 85
finishing of plaster ceiling
L-profile section 4065
self-drilling screw
DIN 7981 ST4.8x19-M-Z
30
60
etalbond
membrane
membrane additional profile E 85612
hard insulation thermal insulation spacer 80 177
15
33 76
20
bracket 71 050
15
transom E 85305
mullion E 85104
gasket 130 480
6 16 6 12 109 21
28 12 130
E85SG6.26
170
scale 3/4
E 85 technical catalogue
01.2011 6.26
curtain wall system E 85
etalbond spandrel panel in brustung zone
170
28 12 130
6 16 6 12 109 21
spacer 33 879
flange 76 651
glazing shim 71 182
transom E 85305
steel sheet 2 mm
self-drilling screw
DIN 7981 ST4.8x16-M-Z
self-drilling screw
DIN 7981 ST4.8x19-M-Z
20 60
thermal insulation spacer 80 177 4 4
28 60
88
etalbond
soft insulation
bracket 71 272
washer DIN 440
steel sheet 2 mm
self-drilling screw
DIN 7981 ST4.8x16-M-Z
mullion E 85104
transom E 85305
thermal insulation spacer 80 177
E85SG6.27
not to scale
E 85 technical catalogue
01.2011 6.27
curtain wall system E 85
upper finishing with etalbond 10
1
4.23
1
4.23
110
20
6 16 6 12 109 21 40
28 12 130 40
170
soft insulation
gypsum board
340
min 30
bracket 71 270
mullion E 85104
E85SG6.28
transom E 85305
not to scale
E 85 technical catalogue
01.2011 6.28
COMBINATIONS
SECTIONS DETAILS
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
50 tapping screw
DIN 7981 ST5.5x45-C-H
15 10 10 15
cover cap E 85713
pressure plate E 85700
gasket 130 500
25
6 5
16
6
12
12
thermal insulation spacer 80 172
gasket 76 651
195.2
flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89
3 3
15 10 10 15
130
18 20 18
fixing part 71 113
transom E 85304
6
mullion E 85104
41
50
E85K7.1
scale 3/4
E 85 technical catalogue
01.2011 7.1
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185
flange 76 664
15
56.3
20
50
min 6
10
tapping screw
5
DIN 7981 ST5.5x25-C-H
15
min 6
fixing part 71 113
transom E 85354
20 5 6 16 6 12 89 41
25 28 12 130
E85K7.2
scale 3/4
E 85 technical catalogue
01.2011 7.2
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
with projected thermo-break window
25
norton tape 6x6.4 mm
6
6
gasket 130 473
6
28
28
16
16
31
16
6
6
6
7
12
gasket 130 176 / P6
9
18 20 18
transom E 85304
79.2
mullion E 85104
41
50
E85K7.3
scale 3/4
E 85 technical catalogue
01.2011 7.3
curtain wall system E 85
combined facade with vertical cap and horizontal silicone joint
with 3rd level transom and projected thermo-break window
6 16 6 7 56 38.2
20
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 473 gasket 130 180
striker 255 602
glass support E 85614
striker 255 603
55.5
38.5
frame E 85410
gasket 130 707
transom E 85354
1
16
14
2
7.9
3
33.3
6
1.6
20.8
50
80 171/80 183
min 6
flange 76 664
fixing part 71 113
gasket 076 651 behind
1.1
gasket 130 463
silicone gasket 130 705
silicone seal
mullion E 85104
20 5 6 16 6 6 6 89 41
25 28 12 130
E85K7.4
scale 3/4
E 85 technical catalogue
01.2011 7.4
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tapping screw
15 20 15 DIN 7981 ST5.5x25-C-H
10 10 glazing clip 71 130
spacer 33 879
15
20
min 6
6 5
min 6 tape
28
16
6
12
12
flange 76 674
5 5
tapping screw
DIN 7981 ST4.8x19-C-H
89
3 3
15 10 10 15
130
18 20 18
fixing part 71 113
transom E 85304
6
mullion E 85104
41
50
E85K7.5
scale 3/4
E 85 technical catalogue
01.2011 7.5
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
56.3
50
50
10
5
15
flange 76 664
fixing part 71 113
transom E 85354
silicone flange 76 680 behind
thermal insulation spacer 80 172
PVC spacer 9020
mullion E 85104
20 28 6 6 89 41
6 16 6 12 130
E85K7.6
scale 3/4
E 85 technical catalogue
01.2011 7.6
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
with parallel opening thermo-break window
silicone seal
min 6
6 5
6
6
28
16
16
6
6
7
9.2
16 21 18
transom E 85304
79.2
41
mullion E 85104
50
E85K7.7
scale 3/4
E 85 technical catalogue
01.2011 7.7
curtain wall system E 85
combined facade with vertical silicone joint and horizontal cap
with 3rd level transom and parallel opening thermo-break window
20
gasket 130 461
norton tape 6x6.4 mm
operating rod E 2308
structural seal 6 mm self-drilling screw
DIN 7981 ST4.8x32-M-Z
8
gasket 130 131 gasket 130 180
33
38.5
frame E 85410
9
transom E 85304
14.4
2
45.8
36
gasket 130 473
50
31
gasket 130 473 3
gasket 130 500 thermal insulation spacer 80 172
20 6 16 6 12 89 41
E85K7.8
scale 3/4
E 85 technical catalogue
01.2011 7.8
curtain wall system E 85
anti-burglar system
mullion with 2nd level transom
143 906
143 907
cover cap E 8700
60
50 009
pressure plate E 8620
gasket 130 500
10
B2310 (P5A)
5
23
tube 47 001
143 905
71 221
89
71 218
130
191
71 228
flange 76 674
transom E 85304
mullion E 85104
41
50
E85K7.9
scale 3/4
E 85 technical catalogue
01.2011 7.9
curtain wall system E 85
anti-burglar system
transom 2nd level drainage
B2310 (P5A)
cover cap E 8701
pressure plate E 8620
gasket 130 500
butyl seal 133 553
thermal insulation spacer 80 171
gasket 130 458
flange 76 674
71 221
56.3
60
50
143 906
143 907 71 218
23 5 23 8 89 41
2
61 130
191
E85K7.10
scale 3/4
E 85 technical catalogue
01.2011 7.10
MACHININGS
MACHINING PROCESSING
curtain wall system E 85
cutting lengths
transom
pressure plate
cover cap
E85M8.1
not to scale
E 85 technical catalogue
01.2011 8.1
curtain wall system E 85
machinings of transom 2nd level drainage with spring t-joint and flange
mullion
A
flange
∅12
transom
18
15
gasket 76 651
DIN 7981 ST4.8x19-C-H
not to scale
E 85 technical catalogue
01.2011 8.2
curtain wall system E 85
machinings of transom 3rd level drainage with spring t-joint and flange
mullion
A flange
∅12
transom
18
tapping screw
DIN 7981 ST4.8x19-C-H
transom flange A mm
E 85360 76 660 -- additional machining of transom for the spring t-joint
E 85351 76 661 --
E 85352 76 662 --
E 85353 76 663 58,5
E 85354 76 664 78,5
E 85355 76 665 98,5
E 85356 76 666 118,5
E 85357 76 667 148,5
E 85358 76 668 168,5
E85M8.3
not to scale
E 85 technical catalogue
01.2011 8.3
curtain wall system E 85
machinings of transom 2nd level drainage with T-joint and flange
mullion
flange
T-joint
transom
18
15
gasket 76 651
tapping screw
DIN 7981 ST4.8x19-C-H
E 85 technical catalogue
01.2011 8.4
curtain wall system E 85
machinings of transom 2nd level drainage with T-joint and flange
mullion
flange
T-joint
transom
18
tapping screw
DIN 7981 ST4.8x19-C-H
E 85 technical catalogue
01.2011 8.5
curtain wall system E 85
machinings of transom 2nd level drainage with transom connectors
7 6.5
15
5
15
mullion 20
46
17 15
8
flange
T-joint
transom
17
15
gasket 76 651
tapping screw
DIN 7981 ST4.8x19-C-H
not to scale
E 85 technical catalogue
01.2011 8.6
curtain wall system E 85
machinings of transom 3rd level drainage with transom connectors
7
6.5
6
5
15
mullion
20
46
17 15
8
flange
T-joint
transom
17
6
silicone flange 76 680
tapping screw
DIN 7981 ST4.8x19-C-H
not to scale
E 85 technical catalogue
01.2011 8.7
curtain wall system E 85
machinings of transom 2nd level drainage with reinforcement
T-joint 71 140
66
22
.5
∅1 0
22.8
87
mullion
4 3
46
∅ 12
19
69
flange 76 676 87
44
∅16
T-joint 71 140
set 71 219
set 71 218
14
∅12
53
gasket 76 651
15.5 18 45
tapping screw
DIN 7981 ST4.8x19-C-H
∅12
reinforcement 85 801 15 53
31
4 .2 4 .2 transom 85306
∅
reinforcement 71 187
8
20
80
92
100 additional
DIN 7981 4.8x19 reinforcement 71 186 /optional/
9
14 12
74 12
100
note:
E85M8.8
In case of 2nd level transom, glazing shim reinforcement should be placed before connecting transom and mullion.
Additional reinforcement 71 186 has to be used in case of thicker glazings.
not to scale
E 85 technical catalogue
01.2011 8.8
curtain wall system E 85
machinings of transom 3rd level drainage with reinforcement
T-joint 71 143
96
22
∅10.5
22.8
132
4 ∅1 3
mullion 2
14
19
flange 76 677 114
132
74
∅16
T-joint 71 143
set 71 219
set 71 218
14
reinforcement 71 188 ∅6
∅ ∅6
4.2 4.2 transom 85357
∅
reinforcement 71 188
8
20 additional
80 reinforcement 71 186 /optional/
92 DIN 7981 4.8x19
100
14 12 8
74 12 92
E85M8.9
100 100
note:
Additional reinforcement 71 186 has to be used in case of thicker glazings.
not to scale
E 85 technical catalogue
01.2011 8.9
curtain wall system E 85
fixing of 3rd level transom using transom connector E 85994 at angle ≥ 90°
mullion
a° = 0° ~ 60°
(D-20) + 50 x sin(a°)
butyl seal X=
76 681 between cos(a°)
mullion and transom
tapping screw
a° DIN 7981 ST4.8x19-C-H
tapping screw b
DIN 7981 ST4.8x19-C-H
tapping screw
DIN 7981 ST4.8x38-C-H
transom
90-a°
transom b, mm
E 85351 25
E 85352 45
E 85353 43
E 85354 63
E 85355 83
E 85356 103
E 85357 133
E 85358 153
E85M8.10
E 85359 173
E 85369 224
not to scale
E 85 technical catalogue
01.2011 8.10
curtain wall system E 85
transom connector E 85994
83.15
68.55
57.2
48.0
40.3
33.6
27.7
22.4
17.5
12.9
8.5
Fixing devices have to 4.2
be placed coaxially Distance between
even though transoms fixing devices must be 0.0
are not parallel. evaluated according to 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60°
the following diagram, a(°)
so that to achieve
smooth transition of a° = 0° ~ 60°
the external webs of
every transom
a°
Capability of fastening
transom by screws on the
frontal face of fixing device
90-a°
not to scale
E 85 technical catalogue
01.2011 8.11
curtain wall system E 85
connection between transom E 85300 and supplementary transom to mullion
supplementary
flange
transom
E 85600 76 650
E 85601 76 652
E 85602 76 653
E 85603 76 654
10
100
supplementary transom
76 650
tapping screw
DIN 7982 ST4.8x19-C-H
E85M8.12
tapping screw
DIN 7981 ST4.8x19-C-H
not to scale
E 85 technical catalogue
01.2011 8.12
01.2011
not to scale
20
B2 20
L1 71 207 20 20 L1 71 065
05 B 2 L 10
5 71 090 B2 B2 05 71 072 58
L1 B1
05
fixing brackets
E 85 technical catalogue
L1
71 270 06
H 120
H 65
H 90
H 72
H 115
52 52 52
52
curtain wall system
52
L1 10 71 565
58 05 71 120 71 290 58 58 71 390
B1 B2
58 L1 B1 B1
B1 05 L1
06 71 015 L1 L1
06 50
H 120
H 65
H 90
H 72
H 115
52 52
51.8 53
8.13
52
20
10 10 71 572 B2 L1 71 265
B2 L1 71 150 71 159 B2 05
50 10 10
B2 B2
L1
50 71 250 L1
L1 50
50
H 120
H 90
H 65
H 72
52
H 115
52 52 53
53
fixed support
movable support
E 85
E85M8.13
curtain wall system E 85
fixing brackets
L1 71 121 71 091
4 05
B8 L1
4 05
B8
H 120
4
L1
05
71 172 H 90 71 372
B8
L1
4 05
B8
H 115
H 72
71 165
4
B8 L1
05
H 65
min
120
fixed support
H
movable support
H/2
E85M8.14
not to scale
E 85 technical catalogue
01.2011 8.14
curtain wall system E 85
anchoring elements for fixing brackets
set for movable support
71 212 - for systems Е85
nut M10
washer 71 208 from profile Е 85901
bush ø15x63
washer 71 208 from profile Е 85901
washer ø10
bolt M10x100
anchor М12х123
washer ø12
nut M12
fixed support
not to scale
E 85 technical catalogue
01.2011 8.15
curtain wall system E 85
simply supported beams
anchor for concrete
(set with washer and nut)
07M12123S
movable
support
bolt M10x100
bush ø15x51
fixed
support
not to scale
E 85 technical catalogue
01.2011 8.16
curtain wall system E 85
beam supported at three points
anchor for concrete
(set with washer and nut)
07M12123S
bolt M10x100
movable B
support
anchor for concrete
(set with washer and nut)
07M12123S
A
movable
support
bolt M10x100
anchor for concrete
(set with washer and nut)
07M12123S
bush ø15x51
fixed
support
not to scale
E 85 technical catalogue
01.2011 8.17
curtain wall system E 85
fixing brackets
43
.2 71 050 or 43.
E 85913 profile 2
E 85918
H 140
profile
nut М12 washer ø12
H 90
B2
20
B2
10
anchor М12х123
anchor M12x123
nut М10
bush ø15x50 / 2pc.
washer ø10
bolt М10x70
min
120
120
H
min
min
min 120
120 120 min
H/2
note:
accessories from profiles E 85913 and E 85918 can be produced and delivered
E85M8.18
E 85 technical catalogue
01.2011 8.18
curtain wall system E 85
combinations and machinings
30
4 30
movable support
mullion
cut for membrane
insert
30
mullion
fixed support ø4 35
ø11
M10x150
membrane
ø8
bar 50x8 mm
10
20
M8x40
B
50
not to scale
E 85 technical catalogue
01.2011 8.19
curtain wall system E 85
connection between two mullions with insert
- The joint of the cover caps must be at least 50 mm lower
than the joint of the pressure plates, which in turn must be 50 tapping screw
mm lower than the joint of the mullions DIN 7981 ST2.9x6.5-C-H
8
upper mullion is sealed with silicone (*).
71 209 (kit)
ST 2,9
Put silicone on
the upper surface
shaped INOX or
aluminium sheet (1mm)
Rectangular standard
profile 40x4 mm
anchored in the middle
of the stiffener by
plastic deformation of
the tracks
ATTENTION:
The cutting length of the
horizontal pressure plate must
not be less than (L-55)
ST 2,9
ATTENTION:
Do not use a screw with greater size than the recommended, 27.5 L - 55
because it has to be covered by the horizontal cover cap L - 51
E85M8.20
not to scale
E 85 technical catalogue
01.2011 8.20
curtain wall system E 85
transom to transom connection
1 1 1 1
2 2 2
2 2 2
2 2
E85M8.21
2 2
not to scale
E 85 technical catalogue
01.2011 8.21
curtain wall system E 85
condensation water drainage
water drainage
*upside down
max 8 m
max 8 m
max 8 m
fill with silicone here
pressure plate
not to scale
E 85 technical catalogue
01.2011 8.22
curtain wall system E 85
bottom finishing
mullion
27 4
transom
bracket 71 050
concrete slab
membrane
E85M8.23
not to scale
E 85 technical catalogue
01.2011 8.23
curtain wall system E 85
fixing of transom E 85320 part of gasket 76 651
tapping screw
DIN 7981 ST2.9x6.5-C-H
a°
36
tapping screw
DIN 7981 ST4.8x19-C-H
accessory 74 674
transom E 85320
membrane
a° = 30° ~ 83°
aluminium sheet
ATTENTION: gasket 130 199
- drainage fitting from profile E 85 991 has to be cut on angle a° for each project
E85M8.24
E 85 technical catalogue
01.2011 8.24
curtain wall system E 85
fixing of transom E 85370 a°
tapping screw
DIN 7981 ST2.9x6.5-C-H
cut from profile 85 911
transom E 85370
a°
accessory 74 674
tapping screw
DIN 7981 ST4.8x19-C-H membrane
6
16
a° = 0° ~ 83°
ATTENTION:
- drainage fitting from profile E 85 991 has to be cut on angle a° for each project
E85M8.25
E 85 technical catalogue
01.2011 8.25
curtain wall system E 85
roof connection of two mullions using E 85960 ATTENTION:
Fasteners, washers, spring
washers etc, must be made of
a° stainless steel A2.
X X B = 25mm (min)
C = B - 4,5mm
X
article has to be cut at two B
points at the peak
axis of measuring angles
ø3
M6
M6 Grooves for
X X TIG-MIG
weldment
C
M8
M8 ATTENTION:
Welding is
compulsory
A
note:
The number of sets 71 216 needed has to be
determined by the facade engineer taking into
consideration the applied loads in each specific case.
not to scale
E 85 technical catalogue
01.2011 8.26
curtain wall system E 85
roof connection of two mullions using E 85969
ATTENTION:
Fasteners, washers, spring
a° washers etc, must be made of
stainless steel A2.
B = Cmin+X
X thickness of wall
bush M8x50
C ATTENTION:
countersunk bolt M8x25 welding is
compulsory
note:
all fixings are included in set 71 216
for roof connection
not to scale
E 85 technical catalogue
01.2011 8.27
curtain wall system E 85
machinings
14.5
23.8
5
5
∅7
23.8 20 10 15 10 30
6 4 2 2.5 2.5
5.5 5
63 25
5.5 5
ATTENTION:
Apart from the submarginal drainage holes which have to be opened in any case
both on the pressure plate and cover cap, additional holes have to be opened in
the middle, in case that the length of the transom is greater than 1.25 m or if the
surface of the glass pane is greater than 2 m²
25
every 180~240
not to scale
E 85 technical catalogue
01.2011 8.28
curtain wall system E 85
water drainage with 2nd level transom
B
A
B-B
28 34
thermal insulation spacer 80 172 thermal insulation spacer 80 172
A-A
150
150
note:
1. In case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone.
E85M8.29
2. In case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is
obligatory to use butyl seal tape in both directions.
not to scale
E 85 technical catalogue
01.2011 8.29
curtain wall system E 85
fixing of E 85723 to E 85745
cap E 85713
cap E 85723
tapping screw
DIN 7981 ST3.5x13-C-H
note:
all big cover caps (E 85723, E85724, E85716, E85718) have
E85M8.30
not to scale
E 85 technical catalogue
01.2011 8.30
curtain wall system E 85
assembling of spacer for structural glazing
B-B
positions 1 2 3 4
outside inside
W1
W3 28
250 120 X 120 X 120 250 6 min 16 6
spacer 33 879
71 130 71 130 71 130
min 100
6
24
17
71 130 71 130
X
71 130 71 130
glazing shim 71 185
X
B
min 100
W1
cutting of spacer
width of spacer W1 = W2 – 34
height of spacer H1 = H2 – 34
100
not to scale
E 85 technical catalogue
01.2011 8.31
curtain wall system E 85
structural glazing assembly
mullion
gasket
tapping screw
DIN ISO 7050 ST5.5x22-C-H
spacer 33 879
E85M8.32
not to scale
E 85 technical catalogue
01.2011 8.32
curtain wall system E 85
projected window fixings and machinings
29.5 12
E 85410 E 85210
5.6 9.6
20.3
10.5
10.5
13
13
40.1
40.1
19
19
6 6
4.5
20
scale 1:2 scale 1:2
54 302
54 457
54 462
54 302
54 457
E85M8.33
54 462
not to scale
E 85 technical catalogue
01.2011 8.33
curtain wall system E 85
machining of drainage opening
E85M8.34
not to scale
E 85 technical catalogue
01.2011 8.34
curtain wall system E 85
machining of glass support E 85615
tapping screw
°
DIN 7982 ST3.5x13-C-H
90
45°
note:
glazing support E 85615 is stocked in
E85M8.35
E 85 technical catalogue
01.2011 8.35
curtain wall system E 85
machining of glass support E 85614
45°
°
90
tapping screw
DIN 7982 ST3.5x13-C-H
note:
E85M8.36
E 85 technical catalogue
01.2011 8.36
curtain wall system E 85
profiles for projected window
tapping screw
DIN 7982 ST3.5x13-C-H
tapping screw
DIN 7982 ST3.5x13-C-H
E85M8.37
not to scale
E 85 technical catalogue
01.2011 8.37
curtain wall system E 85
required machinings of gaskets 130 706 and 130 707 for
projected window used in two sided curtain wall
E85M8.38
note:
cutting of EPDM 130 706 and 130 707 has to be performed with patterns 990 522 and 130 521
not to scale
E 85 technical catalogue
01.2011 8.38
curtain wall system E 85
projected opening window
not to scale
E 85 technical catalogue
01.2011 8.39
curtain wall system E 85
E 85 technical catalogue
01.2011 8.40
curtain wall system E 85
etalbond and glass panels
E 40956 (11mm)
etalbond
E-85291
E-85290
etalbond
ATTENTION:
E85M8.41
E 85 technical catalogue
01.2011 8.41
curtain wall system E 85
etalbond panels
L-20
E 40956 (18.2mm)
50
50
etalbond
E 85290
25
L-20*
ATTENTION:
* correction because of cutting dimensions of panel
etalbond cassette making. are for 4mm etalbond.
E85M8.42
not to scale
E 85 technical catalogue
01.2011 8.42
ACCESSORIES
IMAGES DESCRIPTIONS
code/description package/pcs colour mullion
ET071207 1 MF
ET071090 1 MF
fixing bracket 90 mm
ET071120 1 MF
ET071290 1 MF
fixing bracket 90 mm
E 85 technical catalogue
01.2011 9.1
code/description package/pcs colour
ET071150 1 MF
ET071159 1 MF
fixing bracket 90 mm
ET071270 1 MF
ET071072 1 MF
fixing bracket 72 mm
E 85 technical catalogue
01.2011 9.2
code/description package/pcs colour
ET071265 1 MF
fixing bracket 65 mm
ET071015 1 MF
ET071390 1 MF
fixing bracket 72 mm
ET071065 1 MF
fixing bracket 65 mm
E 85 technical catalogue
01.2011 9.3
code/description package/pcs colour
ET071250 1 MF
ET071572 1 MF
fixing bracket 72 mm
ET071565 1 MF
fixing bracket 65 mm
ET071121 1 MF
E 85 technical catalogue
01.2011 9.4
code/description package/pcs colour
ET071091 1 MF
fixing bracket 90 mm
ET071172 1 MF
ET071372 1 MF
fixing bracket 72 mm
ET071165 1 MF
fixing bracket 65 mm
E 85 technical catalogue
01.2011 9.5
code/description package/pcs colour
ET071050 1 MF
ET071211 1 MF
ET071212 1 MF
ET071213 1 MF
E 85 technical catalogue
01.2011 9.6
code/description package/pcs colour
ET071216 1 MF
ET071218 1 MF
ET071219 1 MF
ET071208 1 MF
washer
E 85 technical catalogue
01.2011 9.7
code/description package/pcs colour
DIN440 MF
washer
07M12123S 1 MF
E 85 technical catalogue
01.2011 9.8
code/description package/pcs colour
ET071209 50 MF
ET074674 50
ET074657 50
ET076651 50
E 85 technical catalogue
01.2011 9.9
code/description package/pcs colour
ET076680 200
ET076681 6m
ET071113 100 MF
ET076671 800
Е-85 301
E 85 technical catalogue
01.2011 9.10
code/description package/pcs colour
ET076672 600
Е-85 302
ET076673 600
Е-85 303
ET076674 400
Е-85 304
ET076675 350
Е-85 305
E 85 technical catalogue
01.2011 9.11
code/description package/pcs colour
ET076676 440
Е-85 306
ET076677 400
Е-85 307
ET076660 100
Е-85 360
ET076661 100
Е-85 351
E 85 technical catalogue
01.2011 9.12
code/description package/pcs colour
ET076662 100
Е-85 352
ET076663 100
Е-85 353
ET076664 100
Е-85 354
ET076665 100
Е-85 355
E 85 technical catalogue
01.2011 9.13
code/description package/pcs colour
ET076666 100
Е-85 356
ET076667 100
Е-85 357
ET076668 100
Е-85 358
ET076669 100
Е-85 359
E 85 technical catalogue
01.2011 9.14
code/description package/pcs colour
ET076670 100
Е-85 369
ET076622 200
Е-85 302
ET076623 200
Е-85 303
ET076624 200
Е-85 351
E 85 technical catalogue
01.2011 9.15
code/description package/pcs colour
ET076625 200
Е-85 352
ET071122 300 MF
Е-85302
ET071123 350 MF
Е-85303
ET071124 280 MF
Е-85304
E 85 technical catalogue
01.2011 9.16
code/description package/pcs colour
ET071125 200 MF
Е-85305
ET071126 170 MF
Е-85306
ET071127 140 MF
Е-85307
ET071131 320 MF
Е-85351
E 85 technical catalogue
01.2011 9.17
code/description package/pcs colour
ET071132 300 MF
Е-85352
ET071133 280 MF
Е-85353
ET071134 210 MF
Е-85354
ET071135 180 MF
Е-85355
E 85 technical catalogue
01.2011 9.18
code/description package/pcs colour
ET071136 156 MF
Е-85356
ET071137 110 MF
Е-85357
ET071138 100 MF
Е-85358
ET071139 96 MF
Е-85359
E 85 technical catalogue
01.2011 9.19
code/description package/pcs colour
ET071144 50 MF
Е-85369
ET71140 100 MF
ET71143 80 MF
ET071152 250 MF
Е-85302
E 85 technical catalogue
01.2011 9.20
code/description package/pcs colour
ET071153 150 MF
Е-85303
ET071141 300 MF
Е-85351
ET071142 150 MF
Е-85352
E 85 technical catalogue
01.2011 9.21
code/description package/pcs colour frame
ET071130 100 MF
ET071109 200 MF
ET071110 100 MF
ET071180 500 MF
E 85 technical catalogue
01.2011 9.22
code/description package/pcs colour
ET071181 200 MF
ET071185 200 MF
ET071182 350 MF
ET071183 300 MF
E 85 technical catalogue
01.2011 9.23
code/description package/pcs colour
ET071184 350 MF
ET071186 200 MF
ET071187 100 MF
ET071188 100 MF
E 85 technical catalogue
01.2011 9.24
code/description package/pcs colour projected window
ET053302 250 MF
Е-85410
ET054457 180 MF
Е-85410
ET054459 200 MF
Е-85200
ET054458 250 MF
Е-85400
E 85 technical catalogue
01.2011 9.25
code/description package/pcs colour
ET054461 100 MF
Е-85211
ET054462 300 MF
Е-85211
E 85 technical catalogue
01.2011 9.26
code/description package/pcs colour gaskets
ET130473 80
EPDM gasket
for glazing 3 mm
ET130474 100
ET130462 100
ET130455 100
E 85 technical catalogue
01.2011 9.27
code/description package/pcs colour
ET130181 200
ET130463 80
ET130457 110
ET130458 100
E 85 technical catalogue
01.2011 9.28
code/description package/pcs colour
ET130167 120
ET130479 100
ET130470 100
ET130182 100
E 85 technical catalogue
01.2011 9.29
code/description package/pcs colour
ET130480 100
ET130500 140
ET130553 160
ET130551 160
E 85 technical catalogue
01.2011 9.30
code/description package/pcs colour
ET130126 110
ET130705 120
ET130180 350
ET130199 100
E 85 technical catalogue
01.2011 9.31
code/description package/pcs colour
ET130198 200
ET130461 110
ET130706 45
ET130707 110
E 85 technical catalogue
01.2011 9.32
code/description package/pcs colour
polyamide joint
ET080171 6
thermal insulation
PVC spacer 16 mm
ET080174 6
thermal insulation
PVC spacer 21 mm
E 85 technical catalogue
01.2011 9.33
code/description package/pcs colour
ET080172 6
thermal insulation
PVC spacer 25 mm
ET080173 6
ET080177 6
24
ET080184 6
thermal insulation 26
spacer PVC 26x28 mm
28
E 85 technical catalogue
01.2011 9.34
code/description package/pcs colour tools
ET162 058 1
ET990 520 1
ET990 523 1
E 85 technical catalogue
01.2011 9.35
code/description package/pcs colour projected window
GI2236 10 MF
GI04041 20
antibreack dispositive
GI4020 10
BE400R 10 MF
E 85 technical catalogue
01.2011 9.36
code/description package/pcs colour
BE600R 10 MF
BE900R 10 MF
BE700R 100 MF
BE800R 100 MF
E 85 technical catalogue
01.2011 9.37
scheme
FIG 1
E 85 technical catalogue
01.2011 9.38
scheme
BE800R
installation on friction
arms with nuts
E 85 technical catalogue
01.2011 9.39
scheme
BE900R
1200 1000 60 3
E 85 technical catalogue
01.2011 9.40
CE MARKING
Aluminium is a very young metal, extracted for the first time in 1854. Commercially produced as a precious
metal from 1886, its industrial production for civil applications only achieved wide use in the 1950’s.
Now aluminium plays a key role for the sustainability of new buildings and the renovation of existing ones.
Thanks to its performance properties aluminium contributes to the energy performance, safety and comfort of
new buildings.
Alloys Finishing
Aluminium in its pure form is a very soft metal. Powder coating – it is a type of paint that is ap-
Thanks to the addition of alloying elements such as plied as a dry powder. Coating is applied on ETEM
copper, manganese, magnesium, zinc, etc. and thanks profiles electrostatically and then is cured under
to suitable production processes, the physical and heat
mechanical properties can be varied in a wide range to allow it to flow and form a ‘’skin’’.
to satisfy the requirements of a large number of
different applications. ETEM is authorized to use the quality sign QUALI-
COAT
ETEM profiles are extruded from the following al- for powder coatings on aluminium for architectural
loys: applications. A wide range of colors and gloss levels
can be achieved.
EN AW-1050 [ Al 99.5 ]
EN AW-6060 [ Al Mg Si ] ETEM also offers timber imitations painting, in addi-
EN AW-6063 [Al Mg0,7 Si] tion to all RAL colors. The technology EZY provides
EN AW-6061 [Al Mg1 Si Cu] the following colors: Golden Oak, Acero, Betulla,
EN AW-6005 [Al Si Mg] Mogano, Verde Scuro, Wenge, Noce Fiammato, Noce
EN AW-6082 [Al Si1 Mg Mn] Chiaro, Ciliegio Rosso, Acacia Scuro, Ciliegio Antico,
Noce Reale, Ciliegio Reale.
E 85 technical catalogue
01.2011 10.1
curtain wall system E85
Standards
E 85 technical catalogue
01.2011 10.2
curtain wall system E85
Curtain wall
Ι. Definition
Curtain walling is a form of predominantly vertical
building envelope which supports no load other than
4. Air permeability
its own weight and the environmental forces which An air permeability test shall be carried out in ac-
act upon it. cordance with the corresponding European standard.
7. Thermal transmittance
1. Resistance to wind load
Methods of assessment / calculation of thermal
The curtain walling shall be sufficiently rigid to re- transmittance of curtain walling and appropriate
sist the declared wind loads for serviceability, both methods of test are defined in EN 13947.
positive and negative. It shall transfer the declared
wind loads to the building’s structure, safely, via 8. Fire resistance
the fixings for that purpose.
Where specifically required the fire resistance shall
be classified in accordance with the corresponding
2. Dead load (Self-weight) European standard.
The curtain wall shall sustain its self-weight plus
any attachments incorporated into it by original 9. Reaction to fire
design. It shall transfer the weight to the building Where specifically required the reaction to fire shall
structure, safely, via the fixings intended for that be classified in accordance with the corresponding
purpose. European standard.
Self-weights shall be determined in accordance with
EN 1991-1-1 ( Eurocode 1).
10. Fire propagation
Where specifically required the curtain wall shall
3. Resistance against impact incorporate such fire and smoke stops as are nec-
essary to prevent the transmission of fire or smoke
Where specifically required tests shall be performed through voids in the curtain wall construction at its
in accordance with the corresponding European abutment at all levels with structural floor slabs.
standard.
E 85 technical catalogue
01.2011 10.3
curtain wall system E85
NOTE:
The beforementioned definition of curtain wall is extract from CWCT Standard for systemized building envelopes.
The listed requirements for curtain walls are in accordance with harmonized European standard EN 13830.
E 85 technical catalogue
01.2011 10.4
curtain wall system E85
CE marking
What does the sign CE mean? - CE ensures free movement of goods within the EU
and the European Free Trade Association (EFTA);
It is an abbreviation of the French “Conformite
Europeene’’- i.e. European Conformity. By placing - CE permits the withdrawal of products that do
the CE marking the manufacturer declares that the not meet
product complies with general safety requirements the standards by monitoring and custom authorities;
set out in CE marking directives.
- Marking with the CE mark is necessary in cases
where the product is distributed within the internal
What is the purpose of CE market.
marking?
What are the requirements
The CE mark represents ‘’the European passport’’ of
the product, its main objectives are:
for the CE marking?
Curtain walls, not concerned with uses subject to
- CE is a declaration by the manufacturer that the
regulations on reaction to fire, are covered by At-
product meets the essential requirements of rel- testation of conformity system 3 (AoC System 3).
evant European legislation relating to health, safety This system sets the following duties:
and environmental protection;
Tasks to be per- Tasks to be performed by Conformity accessment (the basis for CE marking,
formed by the manu- Notified Body which is set by the final producer)
facturer
E 85 technical catalogue
01.2011 10.5
curtain wall system E85
1 Euro Windoor Guidance sheet, CE marking of windows and pedestrian doors, ©EuroWindoor, Frankfurt 2007
E 85 technical catalogue
01.2011 10.6
curtain wall system E85
The procedure for cascading ITT that ETEM Building -The manufacturer undertakes to comply uncondi-
Systems as a system supplier offers to the manu- tionally with all instructions of the system supplier
facturers is as follows: for the product assembly and the method of as-
sembly should be identical to the method of assem-
-The system supplier conducts an initial bling of the sample tested by the system supplier.
inspection of FPC of the manufacturer and all ac- The finished product must have the same technical
companying documents; characteristics as the test sample, otherwise the
manufacturer must test his own product;
-Based on the inspection carried out a contract is
concluded with the system supplier; -The system supplier conducts periodic audits of the
manufacturer, provides technical assistance and
-Ratification of the contract permits the manu- training of the staff of the manufacturer, ongoing
facturer to use the results from the ITT of the consultations and information.
system supplier; Based on the factory production
control system and results from the ITT, the manu-
facturer can certify that the product complies with
current regulations and may affix CE marking;
Legal acts
- 89/106/EEC Construction Products Directive;
- Product standard for curtain walling – EN
13830:2004.
E 85 technical catalogue
01.2011 10.7
curtain wall system E85
Hatches for different materials
Hatches for different materials
PVC membrane
silicone seal
gypsum board
backer rod
wood steel
E 85 technical catalogue
01.2011 10.8
curtain wall system E85
The design, structure and content of this catalogue ЕТЕМ Building Systems is not responsible for any ty-
are subject of copyright and the exclusive rights pographical errors, technical inaccuracies and following
belong to ETEM Building Systems. Modifying, copying, changes of the content of this catalogue.
publishing, selling or licensing any part or the whole
content of this catalogue are strongly prohibited
without the permission of ETEM Building Systems.
Any unauthorized use of content may violate copy-
right or other laws.
E 85 technical catalogue
01.2011 10.9