You are on page 1of 7

Created on: 01/25/2018 13:21:43

Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59

Machines Included:44200153
Report Type: Event
Report Format: Detail
Sort By: Time/Date (Ascending)
Event Filter: Include All Events
Event Category: 1,2,3
Event Type: Data and System Events

Page 1
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59

Machine Event Detail 304


Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/18/2018 20:57:55 58507 2614 Impl Oil Lvl Low 2 00:05:13 0 0
01/19/2018 00:06:47 58510 4916 Lft Cyl Hd Pres SYS EVT 49−364−3 2 00:26:46 1 00:03:03
01/19/2018 00:13:51 58510 2614 Impl Oil Lvl Low 2 00:03:14 0 0
01/19/2018 04:39:29 58512 2614 Impl Oil Lvl Low 2 00:02:21 1 00:01:36
01/19/2018 18:02:34 58524 412 TC Out Temp 129 °C 129 °C 2 00:01:29 0 0
01/19/2018 18:05:28 58524 2752 Impl Oil Temp 93 °C 94 °C 2 00:00:18 0 0
01/19/2018 18:05:28 58524 412 TC Out Temp 129 °C 131 °C 2 00:00:44 0 0
01/19/2018 18:06:17 58524 3556 Brkc Oil Lvl Lo 2 00:01:33 0 0
01/19/2018 18:10:07 58524 3556 Brkc Oil Lvl Lo 2 00:04:17 0 0
01/19/2018 18:11:01 58524 412 TC Out Temp 129 °C 129 °C 2 00:01:32 0 0
01/19/2018 18:19:51 58524 412 TC Out Temp 129 °C 131 °C 2 00:03:30 0 0
01/19/2018 18:22:39 58524 3556 Brkc Oil Lvl Lo 2 00:02:08 0 0
01/20/2018 11:48:17 58540 3556 Brkc Oil Lvl Lo 2 00:09:32 0 0
01/20/2018 11:58:31 58540 3556 Brkc Oil Lvl Lo 2 00:03:29 0 0
01/20/2018 12:13:23 58540 3556 Brkc Oil Lvl Lo 2 00:04:03 0 0
01/20/2018 12:18:27 58540 3556 Brkc Oil Lvl Lo 2 00:08:05 0 0
01/20/2018 12:26:55 58540 3556 Brkc Oil Lvl Lo 2 00:04:37 0 0
01/20/2018 16:54:53 58543 412 TC Out Temp 129 °C 131 °C 2 00:00:58 0 0
01/20/2018 16:54:54 58543 3556 Brkc Oil Lvl Lo 2 00:01:58 0 0
01/20/2018 17:06:34 58543 3556 Brkc Oil Lvl Lo 2 00:01:35 0 0
01/20/2018 17:21:33 58543 3556 Brkc Oil Lvl Lo 2 00:58:48 0 0
01/20/2018 17:47:41 58544 412 TC Out Temp 129 °C 133 °C 2 00:14:22 0 0
01/20/2018 18:13:07 58544 412 TC Out Temp 129 °C 130 °C 2 00:01:51 0 0
01/20/2018 19:14:43 58545 2614 Impl Oil Lvl Low 2 00:02:22 0 0
01/20/2018 20:39:48 58546 891 Impl ECM SYS EVT 82−767−8 2 00:21:42 0 0
01/21/2018 05:08:27 58552 2614 Impl Oil Lvl Low 2 00:02:21 1 00:02:15
01/21/2018 15:20:52 58561 2752 Impl Oil Temp 93 °C 93 °C 2 00:01:12 0 0
01/21/2018 15:39:31 58561 2752 Impl Oil Temp 93 °C 93 °C 2 00:00:58 0 0
01/21/2018 15:48:59 58561 2752 Impl Oil Temp 93 °C 93 °C 2 00:00:45 0 0

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 2
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59
Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/21/2018 15:54:39 58562 2752 Impl Oil Temp 93 °C 93 °C 2 00:01:23 0 0
01/21/2018 16:47:40 58562 2752 Impl Oil Temp 93 °C 93 °C 2 00:02:36 0 0
01/21/2018 16:52:27 58562 2752 Impl Oil Temp 93 °C 95 °C 2 00:02:41 0 0
01/21/2018 17:06:35 58563 3556 Brkc Oil Lvl Lo 2 00:01:52 0 0
01/21/2018 17:07:44 58563 2752 Impl Oil Temp 93 °C 95 °C 2 00:02:12 0 0
01/21/2018 17:18:30 58563 3556 Brkc Oil Lvl Lo 2 00:02:26 0 0
01/21/2018 17:21:38 58563 3556 Brkc Oil Lvl Lo 2 00:01:57 1 00:01:35
01/21/2018 17:23:36 58563 3556 Brkc Oil Lvl Lo 2 00:04:36 0 0
01/21/2018 17:27:22 58563 412 TC Out Temp 129 °C 131 °C 2 00:02:46 0 0
01/21/2018 17:32:45 58563 2752 Impl Oil Temp 93 °C 93 °C 2 00:01:36 0 0
01/21/2018 17:39:30 58563 3556 Brkc Oil Lvl Lo 2 00:02:11 0 0
01/21/2018 17:41:47 58563 412 TC Out Temp 129 °C 131 °C 2 00:06:51 0 0
01/21/2018 17:43:22 58563 3556 Brkc Oil Lvl Lo 2 00:07:45 0 0
01/21/2018 17:57:46 58563 412 TC Out Temp 129 °C 130 °C 2 00:02:06 0 0
01/21/2018 18:05:08 58564 3556 Brkc Oil Lvl Lo 2 00:07:12 0 0
01/21/2018 18:06:59 58564 2752 Impl Oil Temp 93 °C 93 °C 2 00:03:54 0 0
01/21/2018 18:15:06 58564 2752 Impl Oil Temp 93 °C 93 °C 2 00:01:08 0 0
01/21/2018 18:24:29 58564 2752 Impl Oil Temp 93 °C 95 °C 2 00:08:44 0 0
01/21/2018 18:29:58 58564 3556 Brkc Oil Lvl Lo 2 00:05:16 0 0
01/21/2018 18:30:05 58564 412 TC Out Temp 129 °C 130 °C 2 00:02:54 0 0
01/21/2018 18:35:44 58564 3556 Brkc Oil Lvl Lo 2 00:42:47 1 00:36:23
01/21/2018 18:39:11 58564 2752 Impl Oil Temp 93 °C 95 °C 2 00:29:23 0 0
01/21/2018 18:41:07 58564 412 TC Out Temp 129 °C 130 °C 2 00:05:51 0 0
01/21/2018 19:15:54 58565 2752 Impl Oil Temp 93 °C 95 °C 2 00:01:39 0 0
01/21/2018 19:21:49 58565 3556 Brkc Oil Lvl Lo 2 00:19:20 0 0
01/21/2018 19:27:48 58565 2752 Impl Oil Temp 93 °C 95 °C 2 00:03:08 0 0
01/21/2018 19:36:41 58565 2752 Impl Oil Temp 93 °C 93 °C 2 00:01:56 0 0
01/21/2018 19:47:04 58565 3556 Brkc Oil Lvl Lo 2 00:38:37 0 0
01/21/2018 19:56:51 58565 2752 Impl Oil Temp 93 °C 96 °C 2 00:04:29 0 0
01/21/2018 20:04:36 58566 2752 Impl Oil Temp 93 °C 96 °C 2 00:03:59 0 0

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 3
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59
Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/21/2018 20:12:08 58566 2752 Impl Oil Temp 93 °C 94 °C 2 00:00:57 0 0
01/21/2018 20:29:04 58566 3556 Brkc Oil Lvl Lo 2 00:11:02 0 0
01/21/2018 20:41:11 58566 3557 Brkc Oil Lvl Lo 2 00:00:04 0 0
01/22/2018 01:08:29 58569 2752 Impl Oil Temp 93 °C 93 °C 2 00:00:11 0 0
01/22/2018 01:41:40 58570 2614 Impl Oil Lvl Low 2 00:02:23 0 0
01/22/2018 01:53:19 58570 2614 Impl Oil Lvl Low 2 00:02:21 0 0
01/22/2018 14:53:43 58571 2613 Impl Oil Lvl Low 2 00:02:26 0 0
01/22/2018 14:57:09 58571 2614 Impl Oil Lvl Low 2 00:01:39 0 0
01/22/2018 15:13:01 58571 2614 Impl Oil Lvl Low 2 00:05:22 0 0
01/22/2018 17:08:49 58571 2614 Impl Oil Lvl Low 2 00:02:21 1 00:01:50
01/22/2018 17:20:15 58571 2613 Impl Oil Lvl Low 2 00:00:16 0 0
01/22/2018 17:30:38 58572 2614 Impl Oil Lvl Low 2 00:01:56 1 00:01:35
01/22/2018 17:32:53 58572 2614 Impl Oil Lvl Low 2 00:15:28 1 00:01:34
01/22/2018 17:49:29 58572 2614 Impl Oil Lvl Low 2 00:05:50 1 00:01:34
01/22/2018 17:56:03 58572 2614 Impl Oil Lvl Low 2 00:37:03 2 00:01:32
01/22/2018 22:14:13 58575 2752 Impl Oil Temp 93 °C 94 °C 2 00:00:26 0 0
01/22/2018 23:44:28 58577 2614 Impl Oil Lvl Low 2 00:02:25 1 00:01:39
01/23/2018 00:29:05 58577 2614 Impl Oil Lvl Low 2 00:03:04 0 0
01/23/2018 08:21:51 58581 2614 Impl Oil Lvl Low 2 00:04:02 0 0
01/23/2018 08:47:41 58581 2614 Impl Oil Lvl Low 2 00:03:45 0 0
01/23/2018 10:12:35 58583 2614 Impl Oil Lvl Low 2 00:01:31 0 0
01/23/2018 10:52:39 58583 2614 Impl Oil Lvl Low 2 00:02:19 0 0
01/23/2018 13:09:53 58584 2613 Impl Oil Lvl Low 2 00:00:06 0 0
01/23/2018 13:10:01 58584 891 Impl ECM SYS EVT 82−767−8 2 02:45:58 0 0
01/23/2018 15:08:49 58586 2752 Impl Oil Temp 93 °C 94 °C 2 00:01:42 0 0
01/23/2018 15:51:04 58587 412 TC Out Temp 129 °C 129 °C 2 00:00:53 0 0
01/23/2018 16:26:15 58587 3556 Brkc Oil Lvl Lo 2 00:07:32 0 0
01/23/2018 16:38:18 58588 3557 Brkc Oil Lvl Lo 2 00:03:44 0 0
01/23/2018 16:42:17 58588 1585 Eng Cool Temp 107 °C 109 °C 2 00:00:21 0 0
01/23/2018 16:53:46 58588 3556 Brkc Oil Lvl Lo 2 00:27:20 1 00:23:00

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 4
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59
Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/23/2018 17:04:19 58588 412 TC Out Temp 129 °C 129 °C 2 00:07:16 0 0
01/23/2018 17:31:06 58588 3556 Brkc Oil Lvl Lo 2 00:34:24 1 00:30:06
01/23/2018 18:06:42 58589 3556 Brkc Oil Lvl Lo 2 00:18:09 0 0
01/23/2018 18:27:30 58589 3556 Brkc Oil Lvl Lo 2 01:09:19 0 0
01/23/2018 20:31:42 58590 3557 Brkc Oil Lvl Lo 2 00:05:44 1 00:00:04
01/23/2018 21:22:36 58590 891 Impl ECM SYS EVT 82−767−8 2 00:30:33 1 00:02:30
01/23/2018 21:22:45 58590 2614 Impl Oil Lvl Low 2 00:30:13 1 00:02:25
01/23/2018 21:22:45 58590 3556 Brkc Oil Lvl Lo 2 00:30:13 1 00:02:25
01/23/2018 22:34:19 58591 2614 Impl Oil Lvl Low 2 00:02:43 0 0
01/23/2018 23:05:40 58592 3556 Brkc Oil Lvl Lo 2 00:54:58 2 00:01:40
01/24/2018 00:19:12 58592 3557 Brkc Oil Lvl Lo 2 00:00:25 0 0
01/24/2018 00:19:41 58592 3556 Brkc Oil Lvl Lo 2 00:05:30 0 0
01/24/2018 00:27:20 58593 2614 Impl Oil Lvl Low 2 00:03:23 0 0
01/24/2018 00:27:24 58593 3556 Brkc Oil Lvl Lo 2 00:06:48 1 00:04:12
01/24/2018 00:37:41 58593 3556 Brkc Oil Lvl Lo 2 00:08:48 0 0
01/24/2018 00:48:46 58593 3556 Brkc Oil Lvl Lo 2 00:10:31 1 00:10:22
01/24/2018 00:48:51 58593 2614 Impl Oil Lvl Low 2 00:10:45 1 00:10:17
01/24/2018 01:01:00 58593 3556 Brkc Oil Lvl Lo 2 00:16:12 0 0
01/24/2018 01:07:45 58593 2614 Impl Oil Lvl Low 2 00:05:51 0 0
01/24/2018 01:18:16 58593 3556 Brkc Oil Lvl Lo 2 00:01:58 0 0
01/24/2018 01:20:43 58593 3557 Brkc Oil Lvl Lo 2 00:33:02 0 0
01/24/2018 08:15:00 58593 2613 Impl Oil Lvl Low 2 00:00:07 0 0
01/24/2018 08:15:17 58593 3556 Brkc Oil Lvl Lo 2 00:17:08 0 0
01/24/2018 08:32:28 58594 3556 Brkc Oil Lvl Lo 2 00:08:06 0 0
01/24/2018 10:56:17 58596 891 Impl ECM SYS EVT 82−767−8 2 00:30:08 0 0
01/24/2018 14:39:19 58598 412 TC Out Temp 129 °C 132 °C 2 00:21:42 0 0
01/24/2018 14:51:01 58598 3556 Brkc Oil Lvl Lo 2 00:02:35 0 0
01/24/2018 14:57:06 58599 3556 Brkc Oil Lvl Lo 2 00:04:58 0 0
01/24/2018 15:06:23 58599 3556 Brkc Oil Lvl Lo 2 00:03:10 0 0
01/24/2018 16:10:56 58599 3439 Impl Pmp Pres SYS EVT 82−767−3 2 00:00:03 0 0

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 5
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59
Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/24/2018 16:56:17 58600 3556 Brkc Oil Lvl Lo 2 00:06:33 1 00:04:20
01/24/2018 17:02:53 58600 3556 Brkc Oil Lvl Lo 2 01:30:28 3 00:05:37
01/24/2018 17:12:08 58600 412 TC Out Temp 129 °C 131 °C 2 00:07:00 0 0
01/24/2018 17:24:19 58601 412 TC Out Temp 129 °C 131 °C 2 00:08:22 0 0
01/24/2018 17:37:18 58601 412 TC Out Temp 129 °C 131 °C 2 00:05:00 0 0
01/24/2018 17:52:56 58601 412 TC Out Temp 129 °C 131 °C 2 00:03:10 0 0 ss
01/24/2018 17:53:39 58601 413 TC Out Temp 129 °C 129 °C 3 00:02:27 0 0 ss
01/24/2018 17:54:24 58601 1147 VIMS Snapshot 55 % 50 % 1 ACTIVE 9 00:01:51 ss
01/24/2018 17:57:19 58601 412 TC Out Temp 129 °C 131 °C 2 00:06:16 0 0
01/24/2018 18:07:21 58601 412 TC Out Temp 129 °C 131 °C 2 00:07:44 0 0
01/24/2018 18:47:30 58602 3556 Brkc Oil Lvl Lo 2 00:03:47 1 00:01:59
01/24/2018 19:00:29 58602 3556 Brkc Oil Lvl Lo 2 00:06:01 1 00:03:39
01/24/2018 19:10:21 58602 3556 Brkc Oil Lvl Lo 2 00:03:35 1 00:02:21
01/24/2018 19:11:25 58602 2614 Impl Oil Lvl Low 2 00:02:27 0 0
01/24/2018 19:57:15 58602 3556 Brkc Oil Lvl Lo 2 01:04:13 3 00:01:33
01/24/2018 20:41:36 58603 2614 Impl Oil Lvl Low 2 00:19:14 1 00:01:55
01/24/2018 21:37:56 58603 891 Impl ECM SYS EVT 82−767−8 2 00:01:03 0 0
01/24/2018 21:38:00 58603 3557 Brkc Oil Lvl Lo 2 00:09:35 1 00:02:23
01/24/2018 22:27:06 58604 2614 Impl Oil Lvl Low 2 00:20:18 1 00:01:38
01/24/2018 23:04:46 58604 2614 Impl Oil Lvl Low 2 00:01:37 0 0
01/24/2018 23:19:55 58604 2614 Impl Oil Lvl Low 2 00:02:03 1 00:01:33
01/24/2018 23:34:02 58605 2614 Impl Oil Lvl Low 2 00:02:26 1 00:01:45
01/25/2018 05:22:32 58609 2614 Impl Oil Lvl Low 2 00:01:56 0 0
01/25/2018 05:25:05 58609 2614 Impl Oil Lvl Low 2 00:11:10 1 00:01:36
01/25/2018 05:55:11 58610 3556 Brkc Oil Lvl Lo 2 00:01:38 0 0
01/25/2018 08:20:02 58610 3557 Brkc Oil Lvl Lo 2 00:01:04 0 0
01/25/2018 08:20:02 58610 2613 Impl Oil Lvl Low 2 00:01:04 0 0
01/25/2018 08:21:10 58610 2614 Impl Oil Lvl Low 2 00:15:45 0 0
01/25/2018 08:21:10 58610 3556 Brkc Oil Lvl Lo 2 00:15:45 0 0
01/25/2018 11:37:18 58610 2613 Impl Oil Lvl Low 2 00:00:20 0 0

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 6
Date Range: 01/18/2018 00:00:00 − 01/24/2018 23:59:59
Machine Event Detail 304

Time/Date SMH Event Description(ID) Limit Worst Value Event Duration Ack # Ack DL/SS
Id MID−CID−FMI Level Time Link
01/25/2018 11:37:18 58610 3557 Brkc Oil Lvl Lo 2 00:00:20 0 0
01/25/2018 11:37:42 58610 3556 Brkc Oil Lvl Lo 2 00:11:44 1 00:01:30
01/25/2018 11:38:28 58610 2614 Impl Oil Lvl Low 2 00:01:58 0 0
01/25/2018 11:40:55 58610 2614 Impl Oil Lvl Low 2 00:08:31 0 0
01/25/2018 13:06:11 58610 3557 Brkc Oil Lvl Lo 2 ACTIVE 1 00:01:10
01/25/2018 13:06:11 58610 2613 Impl Oil Lvl Low 2 ACTIVE 1 00:01:10

Created on: 01/25/2018 13:21:43 Units: Metric Generated by: None Page 7