You are on page 1of 32

Cat Electronic Technician 2019A v1.

0
Product Status Report

07/04/2020 5:09 PM

Product Status Report


Parameter Value
Engine Serial Number ELM07676
Equipment ID NOT PROGRAMMED
Comments

EMCP 4.2
Parameter Value
ECM Part Number 5034411-00
ECM Serial Number 2079E147TX
Software Group Part Number 5560470-00
Software Group Release Date FEB2018
Software Group Description EMCP 4.2 English, v4.4.3 PROD, 1 February
2018

Logged Diagnostic Codes [SHM: 7 RTC: 06/04/2035 4:39:03 PM] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
No Logged
Diagnostic
Codes

Logged Event Codes [SHM: 7 RTC: 06/04/2035 4:39:03 PM] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
96- 1 Fuel Level : Low - most 1 6:43:33 6:43:33 07/04/2020 07/04/2020
severe (3) 3:27:50 AM 3:27:50 AM
96-17 Fuel Level : Low - least 1 6:43:33 6:43:33 07/04/2020 07/04/2020
severe (1) 3:27:50 AM 3:27:50 AM
100- 1 Engine Oil Pressure : Low 2 4:02:41 6:56:45 06/01/2020 07/04/2020
- most severe (3) 9:35:49 AM 4:29:20 PM
100-17 Engine Oil Pressure : Low 1 4:02:07 4:02:07 06/01/2020 06/01/2020
- least severe (1) 9:35:15 AM 9:35:15 AM
110- 0 Engine Coolant 1 4:10:49 4:10:49 06/01/2020 06/01/2020
Temperature : High - 9:54:34 AM 9:54:34 AM
most severe (3)
110-15 Engine Coolant 1 4:10:08 4:10:08 06/01/2020 06/01/2020
Temperature : High - least 9:53:53 AM 9:53:53 AM
severe (1)
167-17 Charging System 41 0:28:33 6:55:33 20/11/2019 07/04/2020
Potential : Low - least 8:19:31 AM 4:35:56 PM
severe (1)
168-17 Battery Potential / Power 1 6:43:33 6:43:33 07/04/2020 07/04/2020
Input #1 : Low - least 3:28:09 AM 3:28:09 AM
severe (1)
190- 0 Engine Speed : High - 1 4:03:36 4:03:36 06/01/2020 06/01/2020
most severe (3) 9:38:27 AM 9:38:27 AM
970-31 Engine Auxiliary Engine 14 0:28:43 6:49:51 23/10/2019 07/04/2020
Shutdown Switch 10:52:07 4:03:35 PM
AM
1664-31 Engine Automatic Start 2 4:04:33 6:40:33 06/01/2020 06/01/2020
Failed 9:40:20 AM 12:47:17
PM
2440- 1 Generator Average Line- 1 0:29:03 0:29:03 20/11/2019 20/11/2019
Line AC RMS Voltage : 8:21:55 AM 8:21:55 AM
Low - most severe (3)
2440-17 Generator Average Line- 1 0:29:03 0:29:03 20/11/2019 20/11/2019
Line AC RMS Voltage : 8:21:55 AM 8:21:55 AM
Low - least severe (1)
2448- 0 Generator Average AC 1 0:28:44 0:28:44 23/10/2019 23/10/2019
RMS Current : High - 10:52:08 10:52:08
most severe (3) AM AM
2648-31 Maintenance Lamp 49 0:00:03 6:43:33 23/10/2019 07/04/2020
9:32:34 AM 3:00:01 PM
4007-31 Generator Control not in 51 0:00:03 6:55:33 18/10/2019 07/04/2020
Automatic 8:56:31 AM 4:35:27 PM

Active Diagnostic Codes [SHM: 7 RTC: 06/04/2035 4:39:04 PM] - EMCP 4.2
Code Description Occ.
No Active
Diagnostic
Codes

Active Event Codes [SHM: 7 RTC: 06/04/2035 4:39:04 PM] - EMCP 4.2
Code Description Occ.
4007-31 Generator Control not in Automatic 51

Current Totals - EMCP 4.2


Description Value Unit
Total Operating Hours 6.9 hours
Generator Total kW Hours 1773 KW-hr
Export

Configuration - EMCP 4.2


Description Value Unit
Analog Input #1 Signal Type Voltage
Analog Input #1 Signal Range 0.5 to 4.5 V
Analog Input #1 Data Identification Engine Fuel Level
Analog Input #1 Minimum Data Range 0.000
Analog Input #1 Maximum Data Range 100.000
Analog Input #1 High Warning Event 100
Threshold
Analog Input #1 High Warning Event Delay 0.0 sec
Time
Analog Input #1 High Shutdown Event 100
Threshold
Analog Input #1 High Shutdown Event 0.0 sec
Delay Time
Analog Input #1 Low Warning Event 18
Threshold
Analog Input #1 Low Warning Event Delay 10.0 sec
Time
Analog Input #1 Low Shutdown Event 5
Threshold
Analog Input #1 Low Shutdown Event 10.0 sec
Delay Time
Analog Input #2 Signal Type Disabled
Analog Input #3 Signal Type Disabled
Analog Input Supply Voltage 5 Volt
Engine Start Fault Protection Activation 30 sec
Delay Time
Crank Duration 7 sec
Crank Cycle Rest Interval 7 sec
Engine Purge Cycle Time with Ignition 0.0 sec
Engine Purge Cycle Time without Ignition 0 sec
Engine Start Sequence Delay Time 0.0 sec
Maximum Number of Crank Cycles 3
Cooldown Duration 0 min
Start Aid Activation Time 0 sec
Crank Alert Activation Time 0 sec
Crank Terminate RPM 300 rpm
Engine Cooldown Speed Configuration Rated Speed
Engine Operating State Input Configuration Hardwired Input
Fuel Priming Feature Enable Status Disabled
Engine Forced Idle Feature Enable Status Disabled
Emergency Stop Switch Active State High
Configuration
SCADA Data Link Remote Control Enable Disabled
Status
ECU Fault Reset Active Time 0.1 sec
High Battery Voltage Warning Event 31.8 Volts
Threshold
High Battery Voltage Warning Event 30 sec
Notification Delay Time
High Battery Voltage Shutdown Event 32.0 Volts
Threshold
High Battery Voltage Shutdown Event 30 sec
Notification Delay Time
Low Battery Voltage Warning Event 19.0 Volts
Threshold
Low Battery Voltage Warning Event 30 sec
Notification Delay Time
Low Battery Charging System Voltage 25.0 Volts
Warning Event Threshold
Low Battery Charging System Voltage 30 sec
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event 0.0 Volts
Threshold
Low Cranking Voltage Warning Event 2 sec
Notification Delay Time
Customer Password Security Level to 3-Factory, Single Use
Reset Crank/Start Counters
SCADA Data Link Baud Rate 19200 baud
SCADA Data Link Parity None
SCADA Data Link Slave Address 1
SCADA Data Link Access Password 00000000
RS-485 Bias Resistor Enable Status Disabled
SCADA Port Enable Status Enabled
RS-485 Annunciator Port Enable Status Enabled
Digital Input #1 Usage Type System Event
Digital Input #1 Active State Configuration Low
Event Input Function #1 Event Notification 1 sec
Delay Time
Event Input Function #1 Suspect Engine Coolant Level
Parameter Number
Event Input Function #1 Failure Mode Low Shutdown
Identifier
Digital Input #2 Usage Type Disabled
Digital Input #3 Usage Type System Event
Digital Input #3 Active State Configuration Low
Event Input Function #3 Event Notification 1 sec
Delay Time
Event Input Function #3 Suspect Generator Current
Parameter Number
Event Input Function #3 Failure Mode High Shutdown
Identifier
Digital Input #4 Usage Type Disabled
Digital Input #5 Usage Type Disabled
Digital Input #6 Usage Type Disabled
Digital Output #1 Usage Type Command/Status Parameter
Digital Output #1 Command/Status Horn Control
Parameter Data Identification
Digital Output #2 Usage Type Disabled
Engine Coolant Temperature Sensor Data Link
Configuration
High Engine Coolant Temperature Warning 108 Deg C
Event Threshold
High Engine Coolant Temperature Warning 10 sec
Event Notification Delay Time
High Engine Coolant Temperature 111 Deg C
Shutdown Event Threshold
High Engine Coolant Temperature 10 sec
Shutdown Event Notification Delay Time
Low Engine Coolant Temperature Warning 21 Deg C
Event Threshold
Low Engine Coolant Temperature Warning 10 sec
Event Notification Delay Time
Engine Oil Pressure Sensor Configuration Data Link
Low Engine Oil Pressure Warning Event 239 kPa
Threshold
Low Idle Low Engine Oil Pressure Warning 160 kPa
Event Threshold
Low Engine Oil Pressure Warning Event 10 sec
Notification Delay Time
Low Engine Oil Pressure Shutdown Event 205 kPa
Threshold
Low Idle Low Engine Oil Pressure 100 kPa
Shutdown Event Threshold
Low Engine Oil Pressure Shutdown Event 10 sec
Notification Delay Time
Low Engine Oil Pressure Step Speed 1350 rpm
Flywheel Teeth 113
Engine Overspeed Setpoint 1770 rpm
Engine Underspeed Warning Event 1350 rpm
Threshold
Engine Underspeed Warning Event 2.0 sec
Notification Delay Time
Engine Underspeed Shutdown Event 1250 rpm
Threshold
Engine Underspeed Shutdown Event 10.0 sec
Notification Delay Time
Engine Speed Sensor Configuration Data Link
Generator Drive Ratio 1.000 Ratio
Engine Speed Based Generator Frequency Disabled
Calculation Enable
Engine Cylinder Temperature Sensor Not Installed
Installation Status
Number of Engine Cylinders 1
Generator Winding Temperature Sensor Not Installed
Installation Status
Generator Bearing Temperature Sensor Not Installed
Installation Configuration
Accessory Data Link Diagnostic Response Activate Warning Condition
Configuration
Accessory Data Link Diagnostic Audible Yes
Alert
Accessory Data Link Diagnostic Breaker #1 No
Trip
Accessory Data Link Diagnostic Breaker #2 No
Trip
Engine Speed Sensor Diagnostic Activate Hard Shutdown Condition
Response Configuration
Engine Speed Sensor Diagnostic Audible Yes
Alert
Engine Speed Sensor Diagnostic Breaker No
#1 Trip
Engine Speed Sensor Diagnostic Breaker No
#2 Trip
Primary Data Link Diagnostic Response Activate Warning Condition
Configuration
Primary Data Link Diagnostic Audible Alert No
Primary Data Link Diagnostic Breaker #1 No
Trip
Primary Data Link Diagnostic Breaker #2 No
Trip
RS-485 SCADA Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 SCADA Data Link Diagnostic No
Audible Alert
RS-485 SCADA Data Link Diagnostic No
Breaker #1 Trip
RS-485 SCADA Data Link Diagnostic No
Breaker #2 Trip
RS-485 SCADA Data Link Diagnostic Fault No
Protection Timer
RS-485 Annunciator Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 Annunciator Data Link Diagnostic No
Audible Alert
RS-485 Annunciator Data Link Diagnostic No
Breaker #1 Trip
RS-485 Annunciator Data Link Diagnostic No
Breaker #2 Trip
RS-485 Annunciator Data Link Diagnostic No
Fault Protection Timer
Battery Charger Failure Diagnostic Activate Warning Condition
Response Configuration
Battery Charger Failure Diagnostic Audible Yes
Alert
Engine Controller Not Responding Disable Condition
Diagnostic Response Configuration
Engine Controller Not Responding No
Diagnostic Audible Alert
Engine Controller Not Responding No
Diagnostic Breaker #1 Trip
Engine Controller Not Responding No
Diagnostic Breaker #2 Trip
Analog Input #1 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #1 Diagnostic Audible Alert No
Analog Input #1 Diagnostic Breaker #1 Trip No
Analog Input #1 Diagnostic Breaker #2 Trip No
Analog Input #2 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #2 Diagnostic Audible Alert No
Analog Input #2 Diagnostic Breaker #1 Trip No
Analog Input #2 Diagnostic Breaker #2 Trip No
Analog Input #3 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #3 Diagnostic Audible Alert No
Analog Input #3 Diagnostic Breaker #1 Trip No
Analog Input #3 Diagnostic Breaker #2 Trip No
Air Damper Closed Event Response Hard Shutdown & Active Only
Configuration Condition
Air Damper Closed Event Audible Alert Yes
Emergency Stop Activated Event Activate Hard Shutdown Condition
Response Configuration
Emergency Stop Activated Event Audible Yes
Alert
Emergency Stop Activated Event Breaker No
#1 Trip
Emergency Stop Activated Event Breaker No
#2 Trip
High Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
High Engine Coolant Level Warning Event Yes
Audible Alert
High Engine Coolant Level Warning Event No
Breaker #1 Trip
High Engine Coolant Level Warning Event No
Breaker #2 Trip
High Engine Coolant Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Coolant Level Shutdown Yes
Event Audible Alert
High Engine Coolant Level Shutdown No
Event Breaker #1 Trip
High Engine Coolant Level Shutdown No
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Coolant Level Warning Event Yes
Audible Alert
Low Engine Coolant Level Warning Event No
Breaker #1 Trip
Low Engine Coolant Level Warning Event No
Breaker #2 Trip
Low Engine Coolant Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Coolant Level Shutdown Event Yes
Audible Alert
Low Engine Coolant Level Shutdown Event No
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event No
Breaker #2 Trip
High Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Coolant Temperature Warning Yes
Event Audible Alert
High Engine Coolant Temperature Warning No
Event Breaker #1 Trip
High Engine Coolant Temperature Warning No
Event Breaker #2 Trip
High Engine Coolant Temperature Warning Yes
Event Fault Protection Timer
High Engine Coolant Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Engine Coolant Temperature Yes
Shutdown Event Audible Alert
High Engine Coolant Temperature No
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature No
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature Yes
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Coolant Temperature Warning Yes
Event Audible Alert
Low Engine Coolant Temperature Warning No
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning No
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning No
Event Fault Protection Timer
Engine Failure To Start Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Failure To Start Shutdown Event Yes
Audible Alert
Engine Failure To Start Shutdown Event No
Breaker #1 Trip
Engine Failure To Start Shutdown Event No
Breaker #2 Trip
High Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
High Engine Oil Level Warning Event Yes
Audible Alert
High Engine Oil Level Warning Event No
Breaker #1 Trip
High Engine Oil Level Warning Event No
Breaker #2 Trip
High Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Engine Oil Level Shutdown Event Yes
Audible Alert
High Engine Oil Level Shutdown Event No
Breaker #1 Trip
High Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Level Warning Event Yes
Audible Alert
Low Engine Oil Level Warning Event No
Breaker #1 Trip
Low Engine Oil Level Warning Event No
Breaker #2 Trip
Low Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Level Shutdown Event Yes
Audible Alert
Low Engine Oil Level Shutdown Event No
Breaker #1 Trip
Low Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Pressure Warning Event Yes
Audible Alert
Low Engine Oil Pressure Warning Event No
Breaker #1 Trip
Low Engine Oil Pressure Warning Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Yes
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Pressure Shutdown Event Yes
Audible Alert
Low Engine Oil Pressure Shutdown Event No
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event Yes
Fault Protection Timer
High Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Oil Temperature Warning Yes
Event Audible Alert
High Engine Oil Temperature Warning No
Event Breaker #1 Trip
High Engine Oil Temperature Warning No
Event Breaker #2 Trip
High Engine Oil Temperature Warning No
Event Fault Protection Timer
High Engine Oil Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Oil Temperature Shutdown Yes
Event Audible Alert
High Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Low Engine Oil Temperature Warning Disable Condition
Event Response Configuration
Low Engine Oil Temperature Warning No
Event Audible Alert
Low Engine Oil Temperature Warning No
Event Breaker #1 Trip
Low Engine Oil Temperature Warning No
Event Breaker #2 Trip
Low Engine Oil Temperature Warning Yes
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown Disable Condition
Event Response Configuration
Low Engine Oil Temperature Shutdown No
Event Audible Alert
Low Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Unexpected Engine Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Unexpected Engine Shutdown Event Yes
Audible Alert
Unexpected Engine Shutdown Event No
Breaker #1 Trip
Unexpected Engine Shutdown Event No
Breaker #2 Trip
Engine Overspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Overspeed Shutdown Event Yes
Audible Alert
Engine Overspeed Shutdown Event No
Breaker #1 Trip
Engine Overspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Warning Event Activate Warning Condition
Response Configuration
Engine Underspeed Warning Event Audible Yes
Alert
Engine Underspeed Warning Event No
Breaker #1 Trip
Engine Underspeed Warning Event No
Breaker #2 Trip
Engine Underspeed Warning Event Fault Yes
Protection Timer
Engine Underspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Underspeed Shutdown Event Yes
Audible Alert
Engine Underspeed Shutdown Event No
Breaker #1 Trip
Engine Underspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault Yes
Protection Timer
High Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
High Exhaust Temperature Warning Event Yes
Audible Alert
High Exhaust Temperature Warning Event No
Breaker #1 Trip
High Exhaust Temperature Warning Event No
Breaker #2 Trip
High Exhaust Temperature Warning Event No
Fault Protection Timer
High Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Exhaust Temperature Shutdown Yes
Event Audible Alert
High Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
Low Exhaust Temperature Warning Event Yes
Audible Alert
Low Exhaust Temperature Warning Event No
Breaker #1 Trip
Low Exhaust Temperature Warning Event No
Breaker #2 Trip
Low Exhaust Temperature Warning Event Yes
Fault Protection Timer
Low Exhaust Temperature Shutdown Event Disable Condition
Response Configuration
Low Exhaust Temperature Shutdown Event No
Audible Alert
Low Exhaust Temperature Shutdown Event No
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event No
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event No
Fault Protection Timer
High Fuel Level Warning Event Response Disable Condition
Configuration
High Fuel Level Warning Event Audible No
Alert
High Fuel Level Warning Event Breaker #1 No
Trip
High Fuel Level Warning Event Breaker #2 No
Trip
High Fuel Level Shutdown Event Response Disable Condition
Configuration
High Fuel Level Shutdown Event Audible No
Alert
High Fuel Level Shutdown Event Breaker No
#1 Trip
High Fuel Level Shutdown Event Breaker No
#2 Trip
Low Fuel Level Warning Event Response Disable Condition
Configuration
Low Fuel Level Warning Event Audible No
Alert
Low Fuel Level Warning Event Breaker #1 No
Trip
Low Fuel Level Warning Event Breaker #2 No
Trip
Low Fuel Level Shutdown Event Response Disable Condition
Configuration
Low Fuel Level Shutdown Event Audible No
Alert
Low Fuel Level Shutdown Event Breaker No
#1 Trip
Low Fuel Level Shutdown Event Breaker No
#2 Trip
External Tank High Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank High Fuel Level Warning Yes
Event Audible Alert
External Tank High Fuel Level Warning No
Event Breaker #1 Trip
External Tank High Fuel Level Warning No
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank High Fuel Level Shutdown Yes
Event Audible Alert
External Tank High Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown No
Event Breaker #2 Trip
External Tank Low Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank Low Fuel Level Warning Yes
Event Audible Alert
External Tank Low Fuel Level Warning No
Event Breaker #1 Trip
External Tank Low Fuel Level Warning No
Event Breaker #2 Trip
External Tank Low Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank Low Fuel Level Shutdown Yes
Event Audible Alert
External Tank Low Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown No
Event Breaker #2 Trip
Fuel Leak Event Response Configuration Activate Warning Condition
Fuel Leak Event Audible Alert Yes
Fuel Leak Event Breaker #1 Trip No
Fuel Leak Event Breaker #2 Trip No
Service Maintenance Interval Warning Activate Warning Condition
Event Response Configuration
Service Maintenance Interval Warning Yes
Event Audible Alert
High Gas Pressure Warning Event Activate Warning Condition
Response Configuration
High Gas Pressure Warning Event Audible Yes
Alert
High Gas Pressure Warning Event Breaker No
#1 Trip
High Gas Pressure Warning Event Breaker No
#2 Trip
High Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Gas Pressure Shutdown Event Yes
Audible Alert
High Gas Pressure Shutdown Event No
Breaker #1 Trip
High Gas Pressure Shutdown Event No
Breaker #2 Trip
Low Gas Pressure Warning Event Activate Warning Condition
Response Configuration
Low Gas Pressure Warning Event Audible Yes
Alert
Low Gas Pressure Warning Event Breaker No
#1 Trip
Low Gas Pressure Warning Event Breaker No
#2 Trip
Low Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Gas Pressure Shutdown Event Yes
Audible Alert
Low Gas Pressure Shutdown Event No
Breaker #1 Trip
Low Gas Pressure Shutdown Event No
Breaker #2 Trip
Engine Intake Manifold Charge Activate Hard Shutdown Condition
Combustion Event Response Configuration
Engine Intake Manifold Charge Yes
Combustion Event Audible Alert
Engine Intake Manifold Charge No
Combustion Event Breaker #1 Trip
Engine Intake Manifold Charge No
Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge No
Combustion Event Fault Protection Timer
Remote Emergency Stop Activated Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Remote Emergency Stop Activated Yes
Shutdown Event Audible Alert
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #1 Trip
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
High Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
High Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature Yes
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
Low Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
Low Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature Yes
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature Disable Condition
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature No
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Generator Overcurrent Warning Event Activate Warning Condition
Response Configuration
Generator Overcurrent Warning Event Yes
Audible Alert
Generator Overcurrent Warning Event No
Breaker #1 Trip
Generator Overcurrent Warning Event No
Breaker #2 Trip
Generator Overcurrent Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Overcurrent Shutdown Event Yes
Audible Alert
Generator Overcurrent Shutdown Event No
Breaker #1 Trip
Generator Overcurrent Shutdown Event No
Breaker #2 Trip
Generator Over Frequency Warning Event Activate Warning Condition
Response Configuration
Generator Over Frequency Warning Event Yes
Audible Alert
Generator Over Frequency Warning Event No
Breaker #1 Trip
Generator Over Frequency Warning Event No
Breaker #2 Trip
Generator Over Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Over Frequency Shutdown Yes
Event Audible Alert
Generator Over Frequency Shutdown No
Event Breaker #1 Trip
Generator Over Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Warning Activate Warning Condition
Event Response Configuration
Generator Under Frequency Warning Yes
Event Audible Alert
Generator Under Frequency Warning No
Event Breaker #1 Trip
Generator Under Frequency Warning No
Event Breaker #2 Trip
Generator Under Frequency Warning Yes
Event Fault Protection Timer
Generator Under Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Under Frequency Shutdown Yes
Event Audible Alert
Generator Under Frequency Shutdown No
Event Breaker #1 Trip
Generator Under Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Shutdown Yes
Event Fault Protection Timer
Generator Reverse Power Warning Event Activate Warning Condition
Response Configuration
Generator Reverse Power Warning Event Yes
Audible Alert
Generator Reverse Power Warning Event No
Breaker #1 Trip
Generator Reverse Power Warning Event No
Breaker #2 Trip
Generator Reverse Power Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Reverse Power Shutdown Event Yes
Audible Alert
Generator Reverse Power Shutdown Event No
Breaker #1 Trip
Generator Reverse Power Shutdown Event No
Breaker #2 Trip
Generator Over Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Over Voltage Warning Event Yes
Audible Alert
Generator Over Voltage Warning Event No
Breaker #1 Trip
Generator Over Voltage Warning Event No
Breaker #2 Trip
Generator Over Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Over Voltage Shutdown Event Yes
Audible Alert
Generator Over Voltage Shutdown Event No
Breaker #1 Trip
Generator Over Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Under Voltage Warning Event Yes
Audible Alert
Generator Under Voltage Warning Event No
Breaker #1 Trip
Generator Under Voltage Warning Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Yes
Fault Protection Timer
Generator Under Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Under Voltage Shutdown Event Yes
Audible Alert
Generator Under Voltage Shutdown Event No
Breaker #1 Trip
Generator Under Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Shutdown Event Yes
Fault Protection Timer
Earth Fault Event Response Configuration Activate Hard Shutdown Condition
Earth Fault Event Audible Alert Yes
Earth Fault Event Breaker #1 Trip No
Earth Fault Event Breaker #2 Trip No
Generator Winding #1 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #1 High Temperature Yes
Warning Event Audible Alert
Generator Winding #1 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #1 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #1 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Shutdown Event Fault Protection Timer
Generator High Power Warning Event Activate Warning Condition
Response Configuration
Generator High Power Warning Event Yes
Audible Alert
Generator High Power Warning Event No
Breaker #1 Trip
Generator High Power Warning Event No
Breaker #2 Trip
Generator Reverse Reactive Power Activate Warning Condition
Warning Event Response Configuration
Generator Reverse Reactive Power Yes
Warning Event Audible Alert
Generator Reverse Reactive Power No
Warning Event Breaker #1 Trip
Generator Reverse Reactive Power No
Warning Event Breaker #2 Trip
Generator Reverse Reactive Power Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Reverse Reactive Power Yes
Shutdown Event Audible Alert
Generator Reverse Reactive Power No
Shutdown Event Breaker #1 Trip
Generator Reverse Reactive Power No
Shutdown Event Breaker #2 Trip
Programmable Trip Point #1 Condition Disable Condition
Exists Event Response Configuration
Programmable Trip Point #1 Condition No
Exists Event Audible Alert
Programmable Trip Point #1 Condition No
Exists Event Breaker #1 Trip
Programmable Trip Point #1 Condition No
Exists Event Breaker #2 Trip
Programmable Trip Point #1 Condition No
Exists Event Fault Protection Timer
Programmable Trip Point #2 Condition Disable Condition
Exists Event Response Configuration
Programmable Trip Point #2 Condition No
Exists Event Audible Alert
Programmable Trip Point #2 Condition No
Exists Event Breaker #1 Trip
Programmable Trip Point #2 Condition No
Exists Event Breaker #2 Trip
Programmable Trip Point #2 Condition No
Exists Event Fault Protection Timer
High Battery Voltage Warning Event Activate Warning Condition
Response Configuration
High Battery Voltage Warning Event Yes
Audible Alert
High Battery Voltage Warning Event No
Breaker #1 Trip
High Battery Voltage Warning Event No
Breaker #2 Trip
High Battery Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
High Battery Voltage Shutdown Event Yes
Audible Alert
High Battery Voltage Shutdown Event No
Breaker #1 Trip
High Battery Voltage Shutdown Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Activate Warning Condition
Response Configuration
Low Battery Voltage Warning Event Yes
Audible Alert
Low Battery Voltage Warning Event No
Breaker #1 Trip
Low Battery Voltage Warning Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Fault No
Protection Timer
Low Battery Charging System Voltage Activate Warning Condition
Warning Event Response Configuration
Low Battery Charging System Voltage Yes
Warning Event Audible Alert
Low Battery Charging System Voltage No
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage No
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage No
Warning Event Fault Protection Timer
Generator Breaker Open Event Response Active Only Condition
Configuration
Generator Breaker Open Event Audible No
Alert
Generator Breaker Closed Event Response Active Only Condition
Configuration
Generator Breaker Closed Event Audible No
Alert
Engine In Cooldown Event Response Active Only Condition
Configuration
Engine In Cooldown Event Audible Alert No
Engine Speed-Generator Output Freq Activate Warning Condition
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq Yes
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #2 Trip
Generator Control Not in Automatic Activate Warning Condition
Warning Event Response Configuration
Generator Control Not in Automatic Yes
Warning Event Audible Alert
Earth Leakage Event Response Activate Hard Shutdown Condition
Configuration
Earth Leakage Event Audible Alert Yes
Earth Leakage Event Breaker #1 Trip No
Earth Leakage Event Breaker #2 Trip No
Emergency Power System Supplying Load Warning & Active Only Condition
Event Response Configuration
Emergency Power System Supplying Load No
Event Audible Alert
Low Cranking Voltage Warning Event Disable Condition
Response Configuration
Low Cranking Voltage Warning Event No
Audible Alert
Low Cranking Voltage Warning Event No
Breaker #1 Trip
Low Cranking Voltage Warning Event No
Breaker #2 Trip
Analog Input #1 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Custom Event #1 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #1 Condition Exists Event No
Audible Alert
Custom Event #1 Condition Exists Event No
Breaker #1 Trip
Custom Event #1 Condition Exists Event No
Breaker #2 Trip
Custom Event #1 Condition Exists Event No
Fault Protection Timer
Custom Event #2 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #2 Condition Exists Event No
Audible Alert
Custom Event #2 Condition Exists Event No
Breaker #1 Trip
Custom Event #2 Condition Exists Event No
Breaker #2 Trip
Custom Event #2 Condition Exists Event No
Fault Protection Timer
Custom Event #3 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #3 Condition Exists Event No
Audible Alert
Custom Event #3 Condition Exists Event No
Breaker #1 Trip
Custom Event #3 Condition Exists Event No
Breaker #2 Trip
Custom Event #3 Condition Exists Event No
Fault Protection Timer
Custom Event #4 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #4 Condition Exists Event No
Audible Alert
Custom Event #4 Condition Exists Event No
Breaker #1 Trip
Custom Event #4 Condition Exists Event No
Breaker #2 Trip
Custom Event #4 Condition Exists Event No
Fault Protection Timer
Custom Event #5 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #5 Condition Exists Event No
Audible Alert
Custom Event #5 Condition Exists Event No
Breaker #1 Trip
Custom Event #5 Condition Exists Event No
Breaker #2 Trip
Custom Event #5 Condition Exists Event No
Fault Protection Timer
Custom Event #6 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #6 Condition Exists Event No
Audible Alert
Custom Event #6 Condition Exists Event No
Breaker #1 Trip
Custom Event #6 Condition Exists Event No
Breaker #2 Trip
Custom Event #6 Condition Exists Event No
Fault Protection Timer
Engine Running Conditions - Custom Event Activate
Digital Input
Engine Running Conditions - Engine Do Not Activate
Running
Engine Running Conditions - Volts/Hertz Do Not Activate
within Limits
Engine Running Conditions - Engine Do Not Activate
Running at Rated Speed
Fuel Fill/Drain Feature Enable Status Disabled
Fuel Fill Activation Tank Level Percentage 0.0 %
Threshold
Fuel Fill Deactivation Tank Level 100.0 %
Percentage Threshold
Generator Connection Configuration Wye (or Star) Connection
Generator Potential Transformer Primary 1 Volts
Winding Rating
Generator Potential Transformer 1 Volts
Secondary Winding Rating
Generator Current Transformer Primary 1500 Amps
Winding Rating
Generator Current Transformer Secondary 5 Amps
Winding Rating
Number of Generator Poles 4 Poles
Generator Rated Frequency 50 Hz
Generator Rated Voltage 415 Volts
Generator Rated Power 480 kW
Generator Rated Apparent Power 600 kVA
Maximum Generator Voltage Output Bias 5 %
Percentage
Customer Password Security Level to 3-Factory, Single Use
Reset Generator Energy Meters
Generator Definite Time Overcurrent 110 %
Warning Event Percentage Threshold
Generator Inverse Time Overcurrent 0.82 sec
Shutdown Event Time Multiplier
Generator Definite Time Overcurrent 125 %
Shutdown Event Percentage Threshold
Generator Definite Time Overcurrent 10.0 sec
Shutdown Event Notification Delay Time
Generator Inverse Time Over Current 110 %
Shutdown Event Threshold
Generator Inverse Definite Minimum Time Normal Inverse Curve
Curve Type Configuration
Generator Over Frequency Warning Event 105.0 %
Percentage Threshold
Generator Over Frequency Warning Event 10 sec
Notification Delay Time
Generator Over Frequency Shutdown 110.0 %
Event Percentage Threshold
Generator Over Frequency Shutdown 2 sec
Event Notification Delay Time
Generator Under Frequency Warning 95.0 %
Event Percentage Threshold
Generator Under Frequency Warning 10 sec
Event Notification Delay Time
Generator Under Frequency Shutdown 90.0 %
Event Percentage Threshold
Generator Under Frequency Shutdown 4 sec
Event Notification Delay Time
Generator Over Voltage Warning Event 105 %
Percentage Threshold
Generator Over Voltage Warning Event 10 sec
Notification Delay Time
Generator Over Voltage Shutdown Event 110 %
Percentage Threshold
Generator Over Voltage Shutdown Event 2 sec
Notification Delay Time
Generator Under Voltage Warning Event 90 %
Percentage Threshold
Generator Under Voltage Warning Event 10 sec
Notification Delay Time
Generator Under Voltage Shutdown Event 85 %
Percentage Threshold
Generator Under Voltage Shutdown Event 8 sec
Notification Delay Time
Generator Reverse Power Warning Event 5 %
Percentage Threshold
Generator Reverse Power Warning Event 10 sec
Notification Delay Time
Generator Reverse Power Shutdown Event 10 %
Percentage Threshold
Generator Reverse Power Shutdown Event 10 sec
Notification Delay Time
Generator Reverse Reactive Power 5.00 %
Warning Event Percentage Threshold
Generator Reverse Reactive Power 10 sec
Warning Event Notification Delay Time
Generator Reverse Reactive Power 10.00 %
Shutdown Event Percentage Threshold
Generator Reverse Reactive Power 10 sec
Shutdown Event Notification Delay Time
Voltage Regulator Control Source External Control
Configuration
Programmable Cycle Timer #1 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #1 Activation Deactivate
Day - Monday
Programmable Cycle Timer #1 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #1 Activation Deactivate
Day - Friday
Programmable Cycle Timer #1 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #1 Activation 0 min
Start Time
Programmable Cycle Timer #1 Active Time 1 min
Programmable Cycle Timer #1 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #1 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #2 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #2 Activation Deactivate
Day - Monday
Programmable Cycle Timer #2 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #2 Activation Deactivate
Day - Friday
Programmable Cycle Timer #2 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #2 Activation 0 min
Start Time
Programmable Cycle Timer #2 Active Time 1 min
Programmable Cycle Timer #2 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #2 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #3 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #3 Activation Deactivate
Day - Monday
Programmable Cycle Timer #3 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #3 Activation Deactivate
Day - Friday
Programmable Cycle Timer #3 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #3 Activation 0 min
Start Time
Programmable Cycle Timer #3 Active Time 1 min
Programmable Cycle Timer #3 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #3 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #4 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #4 Activation Deactivate
Day - Monday
Programmable Cycle Timer #4 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #4 Activation Deactivate
Day - Friday
Programmable Cycle Timer #4 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #4 Activation 0 min
Start Time
Programmable Cycle Timer #4 Active Time 1 min
Programmable Cycle Timer #4 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #4 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #5 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #5 Activation Deactivate
Day - Monday
Programmable Cycle Timer #5 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #5 Activation Deactivate
Day - Friday
Programmable Cycle Timer #5 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #5 Activation 0 min
Start Time
Programmable Cycle Timer #5 Active Time 1 min
Programmable Cycle Timer #5 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #5 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #6 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #6 Activation Deactivate
Day - Monday
Programmable Cycle Timer #6 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #6 Activation Deactivate
Day - Friday
Programmable Cycle Timer #6 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #6 Activation 0 min
Start Time
Programmable Cycle Timer #6 Active Time 1 min
Programmable Cycle Timer #6 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #6 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #7 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #7 Activation Deactivate
Day - Monday
Programmable Cycle Timer #7 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #7 Activation Deactivate
Day - Friday
Programmable Cycle Timer #7 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #7 Activation 0 min
Start Time
Programmable Cycle Timer #7 Active Time 1 min
Programmable Cycle Timer #7 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #7 Output #2 Inactive
Activation Configuration
Electronic Control Module Reduced Power Enabled
Mode Enable Status
Electronic Control Module Reduced Power 30 min
Mode Delay Time
Relay Output #1 Usage Type Command/Status Parameter
Relay Output #1 Command/Status Starter Motor Relay
Parameter Data Identification
Relay Output #2 Usage Type Command/Status Parameter
Relay Output #2 Command/Status Fuel Control Relay
Parameter Data Identification
Relay Output #3 Usage Type Command/Status Parameter
Relay Output #3 Command/Status Governor ECM Power Relay
Parameter Data Identification
Relay Output #4 Usage Type Command/Status Parameter
Relay Output #4 Command/Status Package Not in Auto
Parameter Data Identification
Relay Output #5 Usage Type Command/Status Parameter
Relay Output #5 Command/Status Common Shutdown
Parameter Data Identification
Relay Output #6 Usage Type Command/Status Parameter
Relay Output #6 Command/Status V/Hz Within Limits
Parameter Data Identification
Relay Output #7 Usage Type Command/Status Parameter
Relay Output #7 Command/Status Engine Started
Parameter Data Identification
Relay Output #8 Usage Type Disabled
Maintenance Level 1 Cycle Interval Hours 500 hours
Maintenance Level 1 Cycle Interval Days 60
Customer Password Security Level to 0-No Security
Reset Service Maintenance Interval
Programmable Trip Point Function #1 Disabled
Trigger Condition
Programmable Trip Point Function #1 0 %
Percentage Threshold
Programmable Trip Point Function #1 0 %
Hysteresis Percentage
Programmable Trip Point Function #1 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #1 Trip 0 sec
Deactivation Delay Time
Programmable Trip Point Function #2 Disabled
Trigger Condition
Programmable Trip Point Function #2 0 %
Percentage Threshold
Programmable Trip Point Function #2 0 %
Hysteresis Percentage
Programmable Trip Point Function #2 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #2 Trip 0 sec
Deactivation Delay Time
Engine Serial Number Not Programmed
Display Pressure Units Configuration kPa
Display Temperature Units Configuration Degrees Centigrade (Celsius)
Display Volume Units Configuration liters

C18 Genset (ELM07676)


Parameter Value
Equipment ID NOT PROGRAMMED
Engine Serial Number ELM07676
ECM Serial Number 18396517JL
Software Group Part Number 5497754-00
Software Group Release Date OCT17
Software Group Description C18-MEUI-ACERT-A4

Logged Diagnostic Codes [Diagnostic Clock = 7 hours] - C18 Genset (ELM07676)


Code Description Occ. First Last
247- 9 SAE J1939 Data Link : Abnormal Update Rate 8 3 7
4- 5 Cylinder #4 Injector : Current Below Normal 2 4 7
175- 3 Engine Oil Temperature Sensor : Voltage Above 1 1 1
Normal

Logged Event Codes [Diagnostic Clock = 7 hours] - C18 Genset (ELM07676)


Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - C18 Genset (ELM07676)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - C18 Genset (ELM07676)


Code Description
No Active
Event Codes

Current Totals - C18 Genset (ELM07676)


Description Value Unit
Total Fuel 504 L
Total Time 7 hours
Engine Starts 23
Average Fuel Rate Based 43 %
Percent Engine Load Factor

Configuration - C18 Genset (ELM07676)


Description Value Unit
Equipment ID NOT PROGRAMMED
Engine Serial Number ELM07676
ECM Serial Number 18396517JL
Software Group Part Number 5497754-00
Software Group Release Date OCT17
Software Group Description C18-MEUI-ACERT-A4
Rating Number 5
Rated Frequency 50 Hz
Rated Engine Speed 1500rpm
Rated Real Genset Power Unavailable Parameter
Rated Apparent Genset Power 660 kVA
Rating Configuration Low BSFC
Test Spec 0K88210K8822
Engine Acceleration Rate 500 rpm/s
Low Idle Speed 1100 rpm
Engine Speed Droop 0.0 %
Remote Throttle Control Min Speed 125 rpm
Remote Throttle Control Max Speed 125 rpm
Crank Terminate RPM 400 rpm
Droop Mode Selection Isochronous
Ether Solenoid Configuration Not Installed
Fuel Filter Differential Pressure Switch Unavailable
Config
Engine Oil Temperature Sensor Installation Not Installed
Status
Desired Speed Input Configuration CAN Input
Secondary Desired Speed Input Not Installed
Configuration
Fuel Enable Input Configuration Switch to Ground
Secondary Fuel Enable Input Enable Enabled
Status
Droop/Isochronous Switch Enable Disabled
Emergency Shutdown Override Switch Not Installed
Installation Status
Emergency Shutdown Override Input Switch to Ground
Configuration
Direct Fuel Control Mode Unavailable
Governor Gain Factor #1 25729
Governor Minimum Stability Factor #1 2135
Governor Maximum Stability Factor #1 2097
FLS -1
FTS 0
Total Tattletale 4

Lifetime: Time vs Engine Coolant Temperature - C18 Genset (ELM07676)


Engine Coolant Temperature( hours %
Deg C )
<50.0 0.20 3.10
50.0-54.0 0.05 0.78
55.0-59.0 0.10 1.55
60.0-64.0 0.15 2.33
65.0-69.0 0.15 2.33
70.0-74.0 0.20 3.10
75.0-79.0 0.25 3.88
80.0-84.0 0.05 0.78
85.0-89.0 2.70 41.86
90.0-94.0 1.30 20.16
95.0-99.0 0.90 13.95
100.0-104.0 0.40 6.20
105.0-109.0 0.00 0.00
110.0-114.0 0.00 0.00
115.0-119.0 0.00 0.00
>120.0 0.00 0.00

Lifetime: Time vs Inlet Air Temperature - C18 Genset (ELM07676)


Inlet Air Temperature( Deg C ) hours %
<40.0 0.00 0.00
40.0-44.0 0.00 0.00
45.0-49.0 0.05 8.33
50.0-54.0 0.25 41.67
55.0-59.0 0.15 25.00
60.0-64.0 0.15 25.00
65.0-69.0 0.00 0.00
70.0-74.0 0.00 0.00
75.0-79.0 0.00 0.00
80.0-84.0 0.00 0.00
85.0-89.0 0.00 0.00
90.0-94.0 0.00 0.00
95.0-99.0 0.00 0.00
>100.0 0.00 0.00

Lifetime: Time vs Boost Pressure - C18 Genset (ELM07676)


Boost Pressure( kPa ) hours %
<80.0 0.00 0.00
80.0-89.0 0.00 0.00
90.0-99.0 0.00 0.00
100.0-109.0 0.00 0.00
110.0-119.0 0.00 0.00
120.0-129.0 0.00 0.00
130.0-139.0 0.00 0.00
140.0-149.0 0.00 0.00
150.0-159.0 0.00 0.00
160.0-169.0 0.00 0.00
170.0-179.0 0.00 0.00
180.0-189.0 0.00 0.00
190.0-199.0 0.00 0.00
>200.0 0.70 100.00

Lifetime: Time vs Engine Speed And Engine Load Factor - C18 Genset (ELM07676)
rpm <1100 1100- 1300- 1500- 1700- 1900- 2100- >2300 Total
1299 1499 1699 1899 2099 2299
%
<50.0 0.00 0.00 0.95 1.05 0.00 0.00 0.00 0.00 2.00
50.0- 0.00 0.00 0.15 0.20 0.00 0.00 0.00 0.00 0.35
59.9
60.0- 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.10
69.9
70.0- 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
79.9
80.0- 0.00 0.00 1.20 1.10 0.00 0.00 0.00 0.00 2.30
89.9
>90.0 0.00 0.00 0.35 0.35 0.00 0.00 0.00 0.00 0.70
Total 0.00 0.00 2.70 2.75 0.00 0.00 0.00 0.00 5.45

Lifetime: Total Occurrences vs Engine Speed - C18 Genset (ELM07676)


Engine Speed( rpm ) %
<2500.0 0.00 0.00
2500.0-2599.0 0.00 0.00
2600.0-2699.0 0.00 0.00
2700.0-2799.0 0.00 0.00
2800.0-2899.0 0.00 0.00
2900.0-2999.0 0.00 0.00
3000.0-3099.0 0.00 0.00
3100.0-3199.0 0.00 0.00
3200.0-3299.0 0.00 0.00
>3300.0 0.00 0.00

Injector Trim Calibration - C18 Genset (ELM07676)


Injector Serial Number File Version
Injector1 000000005A53836312E6 0
Injector2 000000005A538361321A 0
Injector3 000000005A53836321D0 0
Injector4 000000005A53836231AE 0
Injector5 000000005A538361251A 0
Injector6 000000005A5384065126 0

Monitoring System - C18 Genset (ELM07676)


Description State Trip Point Delay Time
Engine Overspeed
Least Severe (1) Always On 2200 rpm 1 sec
Most Severe (3) Always On 2300 rpm 1 sec
High Engine Coolant
Temperature
Least Severe (1) Always On 110 Deg C 10 sec
Moderate Severity (2) Off 111 Deg C 10 sec
Most Severe (3) On 111 Deg C 10 sec
High Engine Inlet Air
Temperature
Least Severe (1) Always On 82.0 Deg C 8 sec
Moderate Severity (2) Off 86.0 Deg C 8 sec
High Engine Oil
Temperature
Least Severe (1) On 110 Deg C 15 sec
Moderate Severity (2) On 115 Deg C 15 sec
Most Severe (3) Off 115 Deg C 15 sec
High Fuel Filter
Pressure Restriction
Least Severe (1) Off None 30 sec
Moderate Severity (2) Off None 28800 sec
Most Severe (3) Off None 28800 sec
High Fuel Pressure
Least Severe (1) On 850.0 kPa 8 sec
Moderate Severity (2) Off 852.0 kPa 10 sec
Most Severe (3) Off 854.0 kPa 12 sec
High Fuel Temperature
Least Severe (1) Always On 90.0 Deg C 30 sec
Moderate Severity (2) Off 91.0 Deg C 10 sec
Most Severe (3) Off 92.0 Deg C 10 sec
Low Engine Oil
Pressure
Least Severe (1) On None 8 sec
Most Severe (3) Always On None 4 sec
Low Fuel Pressure
Least Severe (1) On 550 kPa 10 sec
Moderate Severity (2) Off 540 kPa 10 sec
Most Severe (3) Off 530 kPa 10 sec

You might also like