You are on page 1of 35

Cat Electronic Technician 2019A v1.

0
Product Status Report

20/09/2019 12:16

Product Status Report


Parameter Value
Product ID LY700123
Equipment ID
Comments

EMCP 4.2B
Parameter Value
ECM Part Number 4745636-00
ECM Serial Number 3066E023TU
Software Group Part Number 5014291-00
Software Group Release Date DEC2015
Software Group Description EMCP 4.2B English, v4.7.1 PROD, 19
December 2015

Logged Diagnostic Codes [SHM: 118 RTC: 19/09/1934 12:09:27] - EMCP 4.2B
Code Description Occ. SHM First SHM Last RTC First RTC Last
1383-11 Engine was Shut Down 1 66:45:41 66:45:41 05/12/2018 05/12/2018
Hot : Other Failure Mode 16:40:52 16:40:52

Logged Event Codes [SHM: 118 RTC: 19/09/1934 12:09:27] - EMCP 4.2B
Code Description Occ. SHM First SHM Last RTC First RTC Last
110-17 Engine Coolant 99 3:46:34 85:42:15 24/05/2017 25/03/2019
Temperature : Low - least 15:51:44 01:43:11
severe (1)
168-15 Battery Potential / Power 99 64:49:16 86:04:38 15/11/2018 26/03/2019
Input #1 : High - least 21:40:25 07:54:08
severe (1)
168-17 Battery Potential / Power 13 3:46:34 3:46:34 24/05/2017 24/05/2017
Input #1 : Low - least 15:13:38 15:51:19
severe (1)
970-31 Engine Auxiliary Engine 13 3:48:56 106:54:02 26/02/2018 18/08/2019
Shutdown Switch 17:41:57 15:30:50
2456-15 Generator Total Reactive 99 4:08:34 106:55:50 26/02/2018 18/08/2019
Power : High - least 18:01:56 18:19:25
severe (1)
4007-31 Generator Control not in 22 3:46:34 100:01:34 26/02/2018 01/08/2019
Automatic 17:06:41 07:04:57

Active Diagnostic Codes [SHM: 118 RTC: 19/09/1934 12:09:28] - EMCP 4.2B
Code Description Occ.
No Active
Diagnostic
Codes

Active Event Codes [SHM: 118 RTC: 19/09/1934 12:09:28] - EMCP 4.2B
Code Description Occ.
4007-31 Generator Control not in Automatic 22
4013-31 Generator Circuit Breaker Open 1

Current Totals - EMCP 4.2B


Description Value Unit
Total Operating Hours 117.6 hours
Generator Total kW Hours 41117 KW-hr
Export
Generator Total kVAr Hours 15167 kVAr-hr
Export
Generator Trip kW Hours 41117 KW-hr
Export
Generator Trip kVAr Hours 15167 kVAr-hr
Export

Configuration - EMCP 4.2B


Description Value Unit
Genset Control Software Type Standard
Configuration
Voltage Regulator Control Source Genset Control
Configuration
Voltage Regulator Starting Time 5.0 sec
Voltage Regulator Starting Voltage Percent 10.0 %
Voltage Regulator Loop Gain Percentage 1.00 %
Voltage Regulation Proportional Gain 20.00 %
Percentage
Voltage Regulation Integral Gain 60.00 %
Percentage
Voltage Regulation Derivative Gain 3.00 %
Percentage
Voltage Regulator Noise Filter Time 0.00 sec
Constant
Voltage Regulator Corner (Knee) 49.8 Hz
Frequency
Voltage Regulator Deviation From Corner 5.0 Hz
(Knee) Frequency
Voltage Regulator Volts/Hz Slope 1 2.0 V/Hz
Voltage Regulator Volts/Hz Slope 2 2.0 V/Hz
Voltage Regulator Minimum Voltage 33.0 %
Setpoint Percentage
Voltage Regulator Minimum Frequency 20.0 Hz
Threshold
Voltage Regulator Load Compensation Off
Type Configuration
Voltage Regulator Voltage (IR) 0.0 %
Compensation Percentage
Voltage Regulator Maximum Droop 0.0 %
Percentage
Voltage Regulator Lockout Configuration Not Locked Out
Voltage Regulator Loss of Sensing 2.0 sec
Shutdown Event Notification Delay Time
Voltage Regulator Over Excitation 70 %
Shutdown Event Threshold Percentage
Voltage Regulator Over Excitation 10.0 sec
Shutdown Event Notification Delay Time
Voltage Regulator Excitation Enabled Enabled
During Shutdown Event Configuration
Analog Input #1 Signal Type Voltage
Analog Input #1 Signal Range 0.5 to 4.5 V
Analog Input #1 Data Identification Engine Oil Pressure
Analog Input #1 Minimum Data Range -88.000
Analog Input #1 Maximum Data Range 1100.000
Analog Input #1 Low Warning Event 239
Threshold
Analog Input #1 Low Warning Event Delay 5.0 sec
Time
Analog Input #1 Low Shutdown Event 205
Threshold
Analog Input #1 Low Shutdown Event 5.0 sec
Delay Time
Analog Input #2 Signal Type Voltage
Analog Input #2 Signal Range 0 to 5 V
Analog Input #2 Data Identification Engine Coolant Temperature
Analog Input #2 Minimum Data Range -15.000
Analog Input #2 Maximum Data Range 127.000
Analog Input #2 High Warning Event 102
Threshold
Analog Input #2 High Warning Event Delay 5.0 sec
Time
Analog Input #2 High Shutdown Event 107
Threshold
Analog Input #2 High Shutdown Event 5.0 sec
Delay Time
Analog Input #2 Low Warning Event 21
Threshold
Analog Input #2 Low Warning Event Delay 10.0 sec
Time
Analog Input #3 Signal Type Voltage
Analog Input #3 Signal Range 0 to 5 V
Analog Input #3 Data Identification Engine Oil Temperature
Analog Input #3 Minimum Data Range -15.000
Analog Input #3 Maximum Data Range 127.000
Analog Input #3 High Warning Event 105
Threshold
Analog Input #3 High Warning Event Delay 5.0 sec
Time
Analog Input #3 High Shutdown Event 110
Threshold
Analog Input #3 High Shutdown Event 5.0 sec
Delay Time
Analog Input #3 Low Warning Event 0
Threshold
Analog Input #3 Low Warning Event Delay 0.0 sec
Time
Analog Input #3 Low Shutdown Event 0
Threshold
Analog Input #3 Low Shutdown Event 0.0 sec
Delay Time
Analog Input Supply Voltage 5 Volt
Custom Map #101 Number of Mapped 4
Points
Custom Map #101 Y-Axis Type Custom
Custom Map #101 Map Point X-Axis Value 5.0
#1
Custom Map #101 Map Point Y-Axis Value 0.0
#1
Custom Map #101 Map Point X-Axis Value 10.0
#2
Custom Map #101 Map Point Y-Axis Value 0.0
#2
Custom Map #101 Map Point X-Axis Value 190.0
#3
Custom Map #101 Map Point Y-Axis Value 100.0
#3
Custom Map #101 Map Point X-Axis Value 200.0
#4
Custom Map #101 Map Point Y-Axis Value 100.0
#4
Custom Map #102 Number of Mapped 4
Points
Custom Map #102 Y-Axis Type Custom
Custom Map #102 Map Point X-Axis Value 5.0
#1
Custom Map #102 Map Point Y-Axis Value 0.0
#1
Custom Map #102 Map Point X-Axis Value 10.0
#2
Custom Map #102 Map Point Y-Axis Value 0.0
#2
Custom Map #102 Map Point X-Axis Value 190.0
#3
Custom Map #102 Map Point Y-Axis Value 100.0
#3
Custom Map #102 Map Point X-Axis Value 200.0
#4
Custom Map #102 Map Point Y-Axis Value 100.0
#4
Custom Map #103 Number of Mapped 4
Points
Custom Map #103 Y-Axis Type Custom
Custom Map #103 Map Point X-Axis Value 5.0
#1
Custom Map #103 Map Point Y-Axis Value 0.0
#1
Custom Map #103 Map Point X-Axis Value 10.0
#2
Custom Map #103 Map Point Y-Axis Value 0.0
#2
Custom Map #103 Map Point X-Axis Value 190.0
#3
Custom Map #103 Map Point Y-Axis Value 100.0
#3
Custom Map #103 Map Point X-Axis Value 200.0
#4
Custom Map #103 Map Point Y-Axis Value 100.0
#4
Custom Map #104 Number of Mapped 4
Points
Custom Map #104 Y-Axis Type Custom
Custom Map #104 Map Point X-Axis Value 5.0
#1
Custom Map #104 Map Point Y-Axis Value 0.0
#1
Custom Map #104 Map Point X-Axis Value 10.0
#2
Custom Map #104 Map Point Y-Axis Value 0.0
#2
Custom Map #104 Map Point X-Axis Value 190.0
#3
Custom Map #104 Map Point Y-Axis Value 100.0
#3
Custom Map #104 Map Point X-Axis Value 200.0
#4
Custom Map #104 Map Point Y-Axis Value 100.0
#4
Engine Start Fault Protection Activation 30 sec
Delay Time
Crank Duration 10 sec
Crank Cycle Rest Interval 10 sec
Engine Purge Cycle Time with Ignition 0.0 sec
Engine Purge Cycle Time without Ignition 0 sec
Engine Start Sequence Delay Time 0.0 sec
Maximum Number of Crank Cycles 5
Cooldown Duration 3 min
Start Aid Activation Time 0 sec
Crank Alert Activation Time 0 sec
Crank Terminate RPM 400 rpm
Engine Cooldown Speed Configuration Rated Speed
Engine Operating State Input Configuration Hardwired Input
Fuel Priming Feature Enable Status Disabled
Engine Forced Idle Feature Enable Status Enabled
Emergency Stop Switch Active State High
Configuration
SCADA Data Link Remote Control Enable Disabled
Status
ECU Fault Reset Active Time 0.1 sec
Digital Input Electronic Control Unit Fault Disabled
Reset Enable Status
Engine Crank Delay Time Unavailable sec
High Battery Voltage Warning Event 30.0 Volts
Threshold
High Battery Voltage Warning Event 10 sec
Notification Delay Time
High Battery Voltage Shutdown Event 32.0 Volts
Threshold
High Battery Voltage Shutdown Event 2 sec
Notification Delay Time
Low Battery Voltage Warning Event 23.4 Volts
Threshold
Low Battery Voltage Warning Event 30 sec
Notification Delay Time
Low Battery Charging System Voltage 25.0 Volts
Warning Event Threshold
Low Battery Charging System Voltage 30 sec
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event 14.0 Volts
Threshold
Low Cranking Voltage Warning Event 1 sec
Notification Delay Time
Engine Cooling Fan Minimum Air Flow 101.0 Deg C
Coolant Temperature
Engine Cooling Fan Maximum Air Flow 103.0 Deg C
Coolant Temperature
Engine Cooling Fan Coolant Temperature 16.0 Deg C
Hysteresis
Engine Cooling Fan Minimum Air Flow 15.0 Deg C
Aftercooler Output Air Temperature
Engine Cooling Fan Aftercooler Output Air 20.0 Deg C
Temperature Hysteresis
Engine Cooling Fan Maximum Air Flow 50.0 Deg C
Aftercooler Output Air Temperature
Custom Screen #1 Line #1 Modbus 0
Register Number
Custom Screen #1 Line #2 Modbus 0
Register Number
Custom Screen #1 Line #3 Modbus 0
Register Number
Custom Screen #2 Line #1 Modbus 0
Register Number
Custom Screen #2 Line #2 Modbus 0
Register Number
Custom Screen #2 Line #3 Modbus 0
Register Number
Custom Screen #3 Line #1 Modbus 0
Register Number
Custom Screen #3 Line #2 Modbus 0
Register Number
Custom Screen #3 Line #3 Modbus 0
Register Number
Custom Screen #4 Line #1 Modbus 0
Register Number
Custom Screen #4 Line #2 Modbus 0
Register Number
Custom Screen #4 Line #3 Modbus 0
Register Number
Custom Screen #5 Line #1 Modbus 0
Register Number
Custom Screen #5 Line #2 Modbus 0
Register Number
Custom Screen #5 Line #3 Modbus 0
Register Number
Custom Screen #6 Line #1 Modbus 0
Register Number
Custom Screen #6 Line #2 Modbus 0
Register Number
Custom Screen #6 Line #3 Modbus 0
Register Number
Customer Password Security Level for Factory Default
Analog Input #1
Customer Password Security Level for Factory Default
Analog Input #2
Customer Password Security Level for Factory Default
Analog Input #3
Customer Password Security Level for Factory Default
Digital Inputs
Customer Password Security Level for Factory Default
Digital Outputs
Customer Password Security Level for Factory Default
Relay Outputs
Customer Password Security Level for Factory Default
Automatic Start/Stop
Customer Password Security Level for Fuel Factory Default
Transfer Feature
Customer Password Security Level for Factory Default
Integrated Voltage Regulator
Customer Password Security Level for Factory Default
Programmable Cycle Timer Feature
Customer Password Security Level for Factory Default
Generator Rated Voltages
Customer Password Security Level for Factory Default
Generator Protection Monitoring
Customer Password Security Level for Factory Default
Engine Protection Monitoring
Customer Password Security Level for Factory Default
Custom Display Features
Customer Password Security Level to 3-Factory, Single Use
Reset Crank/Start Counters
SCADA Data Link Baud Rate 19200 baud
SCADA Data Link Parity None
SCADA Data Link Slave Address 1
SCADA Data Link Access Password 00000000
RS-485 Bias Resistor Enable Status Enabled
SCADA Port Enable Status Unavailable
RS-485 Annunciator Port Enable Status Unavailable
Digital Input #1 Usage Type Disabled
Digital Input #2 Usage Type System Event
Digital Input #2 Active State Configuration Low
Event Input Function #2 Event Notification 0 sec
Delay Time
Event Input Function #2 Suspect Custom Event
Parameter Number
Event Input Function #2 Failure Mode Condition Exists
Identifier
Digital Input #3 Usage Type System Event
Digital Input #3 Active State Configuration High
Event Input Function #3 Event Notification 0 sec
Delay Time
Event Input Function #3 Suspect Generator Circuit Breaker Open
Parameter Number
Event Input Function #3 Failure Mode Condition Exists
Identifier
Digital Input #4 Usage Type Disabled
Digital Input #5 Usage Type System Event
Digital Input #5 Active State Configuration High
Event Input Function #5 Event Notification 5 sec
Delay Time
Event Input Function #5 Suspect Engine Coolant Level
Parameter Number
Event Input Function #5 Failure Mode Low Shutdown
Identifier
Digital Input #6 Usage Type Disabled
Digital Output #1 Usage Type Command/Status Parameter
Digital Output #1 Command/Status Disable Aux AC Supply
Parameter Data Identification
Engine Coolant Temperature Sensor Sensor
Configuration
Engine Oil Pressure Sensor Configuration Sensor
Low Idle Low Engine Oil Pressure Warning 104 kPa
Event Threshold
Low Idle Low Engine Oil Pressure 90 kPa
Shutdown Event Threshold
Low Engine Oil Pressure Step Speed 1200 rpm
Flywheel Teeth 183
Engine Overspeed Setpoint 1770 rpm
Engine Underspeed Warning Event 1290 rpm
Threshold
Engine Underspeed Warning Event 10.0 sec
Notification Delay Time
Engine Underspeed Shutdown Event 1230 rpm
Threshold
Engine Underspeed Shutdown Event 10.0 sec
Notification Delay Time
Engine Speed Sensor Configuration Sensor
Generator Drive Ratio 1.000 Ratio
Third Party Engine Low Idle Speed Enable Unavailable
Status
Third Party Engine Low Idle Speed Unavailable rpm
Engine Speed Based Generator Frequency Unavailable
Calculation Enable
Engine Cylinder Temperature Sensor Not Installed
Installation Status
Number of Engine Cylinders 1
Generator Winding Temperature Sensor Installed
Installation Status
Generator Bearing Temperature Sensor Rear
Installation Configuration
Accessory Data Link Diagnostic Response Activate Warning Condition
Configuration
Accessory Data Link Diagnostic Audible Yes
Alert
Accessory Data Link Diagnostic Breaker #1 No
Trip
Accessory Data Link Diagnostic Breaker #2 No
Trip
Engine Speed Sensor Diagnostic Activate Hard Shutdown Condition
Response Configuration
Engine Speed Sensor Diagnostic Audible Yes
Alert
Engine Speed Sensor Diagnostic Breaker No
#1 Trip
Engine Speed Sensor Diagnostic Breaker No
#2 Trip
Primary Data Link Diagnostic Response Activate Warning Condition
Configuration
Primary Data Link Diagnostic Audible Alert No
Primary Data Link Diagnostic Breaker #1 No
Trip
Primary Data Link Diagnostic Breaker #2 No
Trip
RS-485 SCADA Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 SCADA Data Link Diagnostic No
Audible Alert
RS-485 SCADA Data Link Diagnostic No
Breaker #1 Trip
RS-485 SCADA Data Link Diagnostic No
Breaker #2 Trip
RS-485 SCADA Data Link Diagnostic Fault No
Protection Timer
RS-485 Annunciator Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 Annunciator Data Link Diagnostic No
Audible Alert
RS-485 Annunciator Data Link Diagnostic No
Breaker #1 Trip
RS-485 Annunciator Data Link Diagnostic No
Breaker #2 Trip
RS-485 Annunciator Data Link Diagnostic No
Fault Protection Timer
Battery Charger Failure Diagnostic Activate Warning Condition
Response Configuration
Battery Charger Failure Diagnostic Audible Yes
Alert
Engine Controller Not Responding Disable Condition
Diagnostic Response Configuration
Engine Controller Not Responding No
Diagnostic Audible Alert
Engine Controller Not Responding No
Diagnostic Breaker #1 Trip
Engine Controller Not Responding No
Diagnostic Breaker #2 Trip
Analog Input #1 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #1 Diagnostic Audible Alert No
Analog Input #1 Diagnostic Breaker #1 Trip No
Analog Input #1 Diagnostic Breaker #2 Trip No
Analog Input #2 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #2 Diagnostic Audible Alert No
Analog Input #2 Diagnostic Breaker #1 Trip No
Analog Input #2 Diagnostic Breaker #2 Trip No
Analog Input #3 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #3 Diagnostic Audible Alert No
Analog Input #3 Diagnostic Breaker #1 Trip No
Analog Input #3 Diagnostic Breaker #2 Trip No
Air Damper Closed Event Response Hard Shutdown & Active Only
Configuration Condition
Air Damper Closed Event Audible Alert Yes
Emergency Stop Activated Event Activate Hard Shutdown Condition
Response Configuration
Emergency Stop Activated Event Audible Yes
Alert
Emergency Stop Activated Event Breaker No
#1 Trip
Emergency Stop Activated Event Breaker No
#2 Trip
High Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
High Engine Coolant Level Warning Event Yes
Audible Alert
High Engine Coolant Level Warning Event No
Breaker #1 Trip
High Engine Coolant Level Warning Event No
Breaker #2 Trip
High Engine Coolant Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Coolant Level Shutdown Yes
Event Audible Alert
High Engine Coolant Level Shutdown No
Event Breaker #1 Trip
High Engine Coolant Level Shutdown No
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Coolant Level Warning Event Yes
Audible Alert
Low Engine Coolant Level Warning Event No
Breaker #1 Trip
Low Engine Coolant Level Warning Event No
Breaker #2 Trip
Low Engine Coolant Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Coolant Level Shutdown Event Yes
Audible Alert
Low Engine Coolant Level Shutdown Event No
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event No
Breaker #2 Trip
High Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Coolant Temperature Warning Yes
Event Audible Alert
High Engine Coolant Temperature Warning No
Event Breaker #1 Trip
High Engine Coolant Temperature Warning No
Event Breaker #2 Trip
High Engine Coolant Temperature Warning Yes
Event Fault Protection Timer
High Engine Coolant Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Engine Coolant Temperature Yes
Shutdown Event Audible Alert
High Engine Coolant Temperature No
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature No
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature Yes
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Coolant Temperature Warning Yes
Event Audible Alert
Low Engine Coolant Temperature Warning No
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning No
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning No
Event Fault Protection Timer
Engine Failure To Start Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Failure To Start Shutdown Event Yes
Audible Alert
Engine Failure To Start Shutdown Event No
Breaker #1 Trip
Engine Failure To Start Shutdown Event No
Breaker #2 Trip
High Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
High Engine Oil Level Warning Event Yes
Audible Alert
High Engine Oil Level Warning Event No
Breaker #1 Trip
High Engine Oil Level Warning Event No
Breaker #2 Trip
High Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Engine Oil Level Shutdown Event Yes
Audible Alert
High Engine Oil Level Shutdown Event No
Breaker #1 Trip
High Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Level Warning Event Yes
Audible Alert
Low Engine Oil Level Warning Event No
Breaker #1 Trip
Low Engine Oil Level Warning Event No
Breaker #2 Trip
Low Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Level Shutdown Event Yes
Audible Alert
Low Engine Oil Level Shutdown Event No
Breaker #1 Trip
Low Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Pressure Warning Event Yes
Audible Alert
Low Engine Oil Pressure Warning Event No
Breaker #1 Trip
Low Engine Oil Pressure Warning Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Yes
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Pressure Shutdown Event Yes
Audible Alert
Low Engine Oil Pressure Shutdown Event No
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event Yes
Fault Protection Timer
High Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Oil Temperature Warning Yes
Event Audible Alert
High Engine Oil Temperature Warning No
Event Breaker #1 Trip
High Engine Oil Temperature Warning No
Event Breaker #2 Trip
High Engine Oil Temperature Warning No
Event Fault Protection Timer
High Engine Oil Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Oil Temperature Shutdown Yes
Event Audible Alert
High Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Low Engine Oil Temperature Warning Disable Condition
Event Response Configuration
Low Engine Oil Temperature Warning No
Event Audible Alert
Low Engine Oil Temperature Warning No
Event Breaker #1 Trip
Low Engine Oil Temperature Warning No
Event Breaker #2 Trip
Low Engine Oil Temperature Warning Yes
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown Disable Condition
Event Response Configuration
Low Engine Oil Temperature Shutdown No
Event Audible Alert
Low Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Unexpected Engine Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Unexpected Engine Shutdown Event Yes
Audible Alert
Unexpected Engine Shutdown Event No
Breaker #1 Trip
Unexpected Engine Shutdown Event No
Breaker #2 Trip
Engine Overspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Overspeed Shutdown Event Yes
Audible Alert
Engine Overspeed Shutdown Event No
Breaker #1 Trip
Engine Overspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Warning Event Activate Warning Condition
Response Configuration
Engine Underspeed Warning Event Audible Yes
Alert
Engine Underspeed Warning Event No
Breaker #1 Trip
Engine Underspeed Warning Event No
Breaker #2 Trip
Engine Underspeed Warning Event Fault Yes
Protection Timer
Engine Underspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Underspeed Shutdown Event Yes
Audible Alert
Engine Underspeed Shutdown Event No
Breaker #1 Trip
Engine Underspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault Yes
Protection Timer
High Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
High Exhaust Temperature Warning Event Yes
Audible Alert
High Exhaust Temperature Warning Event No
Breaker #1 Trip
High Exhaust Temperature Warning Event No
Breaker #2 Trip
High Exhaust Temperature Warning Event No
Fault Protection Timer
High Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Exhaust Temperature Shutdown Yes
Event Audible Alert
High Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
Low Exhaust Temperature Warning Event Yes
Audible Alert
Low Exhaust Temperature Warning Event No
Breaker #1 Trip
Low Exhaust Temperature Warning Event No
Breaker #2 Trip
Low Exhaust Temperature Warning Event Yes
Fault Protection Timer
Low Exhaust Temperature Shutdown Event Disable Condition
Response Configuration
Low Exhaust Temperature Shutdown Event No
Audible Alert
Low Exhaust Temperature Shutdown Event No
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event No
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event No
Fault Protection Timer
High Fuel Level Warning Event Response Activate Warning Condition
Configuration
High Fuel Level Warning Event Audible Yes
Alert
High Fuel Level Warning Event Breaker #1 No
Trip
High Fuel Level Warning Event Breaker #2 No
Trip
High Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
High Fuel Level Shutdown Event Audible Yes
Alert
High Fuel Level Shutdown Event Breaker No
#1 Trip
High Fuel Level Shutdown Event Breaker No
#2 Trip
Low Fuel Level Warning Event Response Activate Warning Condition
Configuration
Low Fuel Level Warning Event Audible Yes
Alert
Low Fuel Level Warning Event Breaker #1 No
Trip
Low Fuel Level Warning Event Breaker #2 No
Trip
Low Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
Low Fuel Level Shutdown Event Audible Yes
Alert
Low Fuel Level Shutdown Event Breaker No
#1 Trip
Low Fuel Level Shutdown Event Breaker No
#2 Trip
External Tank High Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank High Fuel Level Warning Yes
Event Audible Alert
External Tank High Fuel Level Warning No
Event Breaker #1 Trip
External Tank High Fuel Level Warning No
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank High Fuel Level Shutdown Yes
Event Audible Alert
External Tank High Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown No
Event Breaker #2 Trip
External Tank Low Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank Low Fuel Level Warning Yes
Event Audible Alert
External Tank Low Fuel Level Warning No
Event Breaker #1 Trip
External Tank Low Fuel Level Warning No
Event Breaker #2 Trip
External Tank Low Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank Low Fuel Level Shutdown Yes
Event Audible Alert
External Tank Low Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown No
Event Breaker #2 Trip
Fuel Leak Event Response Configuration Activate Warning Condition
Fuel Leak Event Audible Alert Yes
Fuel Leak Event Breaker #1 Trip No
Fuel Leak Event Breaker #2 Trip No
Service Maintenance Interval Warning Disable Condition
Event Response Configuration
Service Maintenance Interval Warning No
Event Audible Alert
High Gas Pressure Warning Event Activate Warning Condition
Response Configuration
High Gas Pressure Warning Event Audible Yes
Alert
High Gas Pressure Warning Event Breaker No
#1 Trip
High Gas Pressure Warning Event Breaker No
#2 Trip
High Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Gas Pressure Shutdown Event Yes
Audible Alert
High Gas Pressure Shutdown Event No
Breaker #1 Trip
High Gas Pressure Shutdown Event No
Breaker #2 Trip
Low Gas Pressure Warning Event Activate Warning Condition
Response Configuration
Low Gas Pressure Warning Event Audible Yes
Alert
Low Gas Pressure Warning Event Breaker No
#1 Trip
Low Gas Pressure Warning Event Breaker No
#2 Trip
Low Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Gas Pressure Shutdown Event Yes
Audible Alert
Low Gas Pressure Shutdown Event No
Breaker #1 Trip
Low Gas Pressure Shutdown Event No
Breaker #2 Trip
Engine Intake Manifold Charge Activate Hard Shutdown Condition
Combustion Event Response Configuration
Engine Intake Manifold Charge Yes
Combustion Event Audible Alert
Engine Intake Manifold Charge No
Combustion Event Breaker #1 Trip
Engine Intake Manifold Charge No
Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge No
Combustion Event Fault Protection Timer
Remote Emergency Stop Activated Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Remote Emergency Stop Activated Yes
Shutdown Event Audible Alert
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #1 Trip
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #2 Trip
High Engine Fluid Bund Level Warning Activate Warning Condition
Event Response Configuration
High Engine Fluid Bund Level Warning Yes
Event Audible Alert
High Engine Fluid Bund Level Warning No
Event Breaker #1 Trip
High Engine Fluid Bund Level Warning No
Event Breaker #2 Trip
High Engine Fluid Bund Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Fluid Bund Level Shutdown Yes
Event Audible Alert
High Engine Fluid Bund Level Shutdown No
Event Breaker #1 Trip
High Engine Fluid Bund Level Shutdown No
Event Breaker #2 Trip
Engine Derate Event Response Unavailable
Configuration
Engine Derate Event Audible Alert Unavailable
High Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
High Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
High Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature Yes
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
Low Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
Low Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature Yes
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature Disable Condition
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature No
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Generator Overcurrent Warning Event Activate Warning Condition
Response Configuration
Generator Overcurrent Warning Event Yes
Audible Alert
Generator Overcurrent Warning Event No
Breaker #1 Trip
Generator Overcurrent Warning Event No
Breaker #2 Trip
Generator Overcurrent Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Overcurrent Shutdown Event Yes
Audible Alert
Generator Overcurrent Shutdown Event No
Breaker #1 Trip
Generator Overcurrent Shutdown Event No
Breaker #2 Trip
Generator Over Frequency Warning Event Activate Warning Condition
Response Configuration
Generator Over Frequency Warning Event Yes
Audible Alert
Generator Over Frequency Warning Event No
Breaker #1 Trip
Generator Over Frequency Warning Event No
Breaker #2 Trip
Generator Over Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Over Frequency Shutdown Yes
Event Audible Alert
Generator Over Frequency Shutdown No
Event Breaker #1 Trip
Generator Over Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Warning Activate Warning Condition
Event Response Configuration
Generator Under Frequency Warning Yes
Event Audible Alert
Generator Under Frequency Warning No
Event Breaker #1 Trip
Generator Under Frequency Warning No
Event Breaker #2 Trip
Generator Under Frequency Warning Yes
Event Fault Protection Timer
Generator Under Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Under Frequency Shutdown Yes
Event Audible Alert
Generator Under Frequency Shutdown No
Event Breaker #1 Trip
Generator Under Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Shutdown Yes
Event Fault Protection Timer
Generator Reverse Power Warning Event Activate Warning Condition
Response Configuration
Generator Reverse Power Warning Event Yes
Audible Alert
Generator Reverse Power Warning Event No
Breaker #1 Trip
Generator Reverse Power Warning Event No
Breaker #2 Trip
Generator Reverse Power Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Reverse Power Shutdown Event Yes
Audible Alert
Generator Reverse Power Shutdown Event No
Breaker #1 Trip
Generator Reverse Power Shutdown Event No
Breaker #2 Trip
Generator Over Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Over Voltage Warning Event Yes
Audible Alert
Generator Over Voltage Warning Event No
Breaker #1 Trip
Generator Over Voltage Warning Event No
Breaker #2 Trip
Generator Over Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Over Voltage Shutdown Event Yes
Audible Alert
Generator Over Voltage Shutdown Event No
Breaker #1 Trip
Generator Over Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Under Voltage Warning Event Yes
Audible Alert
Generator Under Voltage Warning Event No
Breaker #1 Trip
Generator Under Voltage Warning Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Yes
Fault Protection Timer
Generator Under Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Under Voltage Shutdown Event Yes
Audible Alert
Generator Under Voltage Shutdown Event No
Breaker #1 Trip
Generator Under Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Shutdown Event Yes
Fault Protection Timer
Earth Fault Event Response Configuration Activate Hard Shutdown Condition
Earth Fault Event Audible Alert Yes
Earth Fault Event Breaker #1 Trip No
Earth Fault Event Breaker #2 Trip No
Generator Winding #1 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #1 High Temperature Yes
Warning Event Audible Alert
Generator Winding #1 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #1 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #1 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Shutdown Event Fault Protection Timer
Generator High Power Warning Event Activate Warning Condition
Response Configuration
Generator High Power Warning Event Yes
Audible Alert
Generator High Power Warning Event No
Breaker #1 Trip
Generator High Power Warning Event No
Breaker #2 Trip
Generator Reverse Reactive Power Activate Warning Condition
Warning Event Response Configuration
Generator Reverse Reactive Power No
Warning Event Audible Alert
Generator Reverse Reactive Power No
Warning Event Breaker #1 Trip
Generator Reverse Reactive Power No
Warning Event Breaker #2 Trip
Generator Reverse Reactive Power Disable Condition
Shutdown Event Response Configuration
Generator Reverse Reactive Power No
Shutdown Event Audible Alert
Generator Reverse Reactive Power No
Shutdown Event Breaker #1 Trip
Generator Reverse Reactive Power No
Shutdown Event Breaker #2 Trip
Programmable Trip Point #1 Condition Disable Condition
Exists Event Response Configuration
Programmable Trip Point #1 Condition No
Exists Event Audible Alert
Programmable Trip Point #1 Condition No
Exists Event Breaker #1 Trip
Programmable Trip Point #1 Condition No
Exists Event Breaker #2 Trip
Programmable Trip Point #1 Condition No
Exists Event Fault Protection Timer
Programmable Trip Point #2 Condition Disable Condition
Exists Event Response Configuration
Programmable Trip Point #2 Condition No
Exists Event Audible Alert
Programmable Trip Point #2 Condition No
Exists Event Breaker #1 Trip
Programmable Trip Point #2 Condition No
Exists Event Breaker #2 Trip
Programmable Trip Point #2 Condition No
Exists Event Fault Protection Timer
Generator Output Sensing System Disable Condition
Diagnostic Response Configuration
Generator Output Sensing System No
Diagnostic Audible Alert
Generator Output Sensing System No
Diagnostic Breaker #1 Trip
Generator Output Sensing System No
Diagnostic Breaker #2 Trip
Generator Output Sensing System No
Diagnostic Fault Protection Timer
Programmable Trip Point #3 Condition Disable Condition
Exists Event Response Configuration
Programmable Trip Point #3 Condition No
Exists Event Audible Alert
Programmable Trip Point #3 Condition No
Exists Event Breaker #1 Trip
Programmable Trip Point #3 Condition No
Exists Event Breaker #2 Trip
Programmable Trip Point #3 Condition No
Exists Event Fault Protection Timer
High Battery Voltage Warning Event Activate Warning Condition
Response Configuration
High Battery Voltage Warning Event Yes
Audible Alert
High Battery Voltage Warning Event No
Breaker #1 Trip
High Battery Voltage Warning Event No
Breaker #2 Trip
High Battery Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
High Battery Voltage Shutdown Event Yes
Audible Alert
High Battery Voltage Shutdown Event No
Breaker #1 Trip
High Battery Voltage Shutdown Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Activate Warning Condition
Response Configuration
Low Battery Voltage Warning Event Yes
Audible Alert
Low Battery Voltage Warning Event No
Breaker #1 Trip
Low Battery Voltage Warning Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Fault No
Protection Timer
Low Battery Charging System Voltage Disable Condition
Warning Event Response Configuration
Low Battery Charging System Voltage No
Warning Event Audible Alert
Low Battery Charging System Voltage No
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage No
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage No
Warning Event Fault Protection Timer
Generator Breaker Open Event Response Active Only Condition
Configuration
Generator Breaker Open Event Audible No
Alert
Generator Breaker Closed Event Response Active Only Condition
Configuration
Generator Breaker Closed Event Audible No
Alert
Engine In Cooldown Event Response Active Only Condition
Configuration
Engine In Cooldown Event Audible Alert No
Engine Speed-Generator Output Freq Activate Warning Condition
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq Yes
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #2 Trip
Generator Control Not in Automatic Activate Warning Condition
Warning Event Response Configuration
Generator Control Not in Automatic Yes
Warning Event Audible Alert
Earth Leakage Event Response Activate Hard Shutdown Condition
Configuration
Earth Leakage Event Audible Alert Yes
Earth Leakage Event Breaker #1 Trip No
Earth Leakage Event Breaker #2 Trip No
Emergency Power System Supplying Load Warning & Active Only Condition
Event Response Configuration
Emergency Power System Supplying Load No
Event Audible Alert
Low Cranking Voltage Warning Event Disable Condition
Response Configuration
Low Cranking Voltage Warning Event No
Audible Alert
Low Cranking Voltage Warning Event No
Breaker #1 Trip
Low Cranking Voltage Warning Event No
Breaker #2 Trip
Analog Input #1 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Loss of Utility Event Response Warning & Active Only Condition
Configuration
Loss of Utility Event Audible Alert Yes
Loss of Utility Event Breaker #1 Trip No
Loss of Utility Event Breaker #2 Trip No
Loss of Utility Event Loss of Utility Yes
Utility to Generator Transfer Failure Disable Condition
Warning Event Response Configuration
Utility to Generator Transfer Failure No
Warning Event Audible Alert
Utility to Generator Transfer Failure No
Warning Event Breaker #1 Trip
Utility to Generator Transfer Failure No
Warning Event Breaker #2 Trip
Utility to Generator Transfer Failure Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Utility to Generator Transfer Failure Yes
Shutdown Event Audible Alert
Utility to Generator Transfer Failure Yes
Shutdown Event Breaker #1 Trip
Utility to Generator Transfer Failure No
Shutdown Event Breaker #2 Trip
Generator to Utility Transfer Failure Activate Warning Condition
Warning Event Response Configuration
Generator to Utility Transfer Failure Yes
Warning Event Audible Alert
Generator to Utility Transfer Failure No
Warning Event Breaker #1 Trip
Generator to Utility Transfer Failure No
Warning Event Breaker #2 Trip
Generator to Utility Transfer Failure Yes
Warning Event Loss of Utility
Utility Breaker System Fault Event Activate Warning Condition
Response Configuration
Utility Breaker System Fault Event Audible Yes
Alert
Utility Breaker System Fault Event Breaker No
#1 Trip
Utility Breaker System Fault Event Breaker No
#2 Trip
Utility Breaker System Fault Event Loss of Yes
Utility
Utility Breaker Failure To Open Event Activate Hard Shutdown Condition
Response Configuration
Utility Breaker Failure To Open Event Yes
Audible Alert
Utility Breaker Failure To Open Event No
Breaker #1 Trip
Utility Breaker Failure To Open Event No
Breaker #2 Trip
Utility Breaker Failure To Close Event Activate Warning Condition
Response Configuration
Utility Breaker Failure To Close Event Yes
Audible Alert
Utility Breaker Failure To Close Event No
Breaker #1 Trip
Utility Breaker Failure To Close Event No
Breaker #2 Trip
Utility Breaker Failure To Close Event Loss Yes
of Utility
Custom Event #1 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #1 Condition Exists Event No
Audible Alert
Custom Event #1 Condition Exists Event No
Breaker #1 Trip
Custom Event #1 Condition Exists Event No
Breaker #2 Trip
Custom Event #1 Condition Exists Event No
Fault Protection Timer
Custom Event #2 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #2 Condition Exists Event No
Audible Alert
Custom Event #2 Condition Exists Event No
Breaker #1 Trip
Custom Event #2 Condition Exists Event No
Breaker #2 Trip
Custom Event #2 Condition Exists Event No
Fault Protection Timer
Custom Event #3 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #3 Condition Exists Event No
Audible Alert
Custom Event #3 Condition Exists Event No
Breaker #1 Trip
Custom Event #3 Condition Exists Event No
Breaker #2 Trip
Custom Event #3 Condition Exists Event No
Fault Protection Timer
Custom Event #4 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #4 Condition Exists Event No
Audible Alert
Custom Event #4 Condition Exists Event No
Breaker #1 Trip
Custom Event #4 Condition Exists Event No
Breaker #2 Trip
Custom Event #4 Condition Exists Event No
Fault Protection Timer
Custom Event #5 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #5 Condition Exists Event No
Audible Alert
Custom Event #5 Condition Exists Event No
Breaker #1 Trip
Custom Event #5 Condition Exists Event No
Breaker #2 Trip
Custom Event #5 Condition Exists Event No
Fault Protection Timer
Custom Event #6 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #6 Condition Exists Event No
Audible Alert
Custom Event #6 Condition Exists Event No
Breaker #1 Trip
Custom Event #6 Condition Exists Event No
Breaker #2 Trip
Custom Event #6 Condition Exists Event No
Fault Protection Timer
Engine Running Conditions - Custom Event Activate
Digital Input
Engine Running Conditions - Engine Do Not Activate
Running
Engine Running Conditions - Volts/Hertz Do Not Activate
within Limits
Engine Running Conditions - Engine Do Not Activate
Running at Rated Speed
Fuel Fill/Drain Feature Enable Status Disabled
Fuel Fill Activation Tank Level Percentage 0.0 %
Threshold
Fuel Fill Deactivation Tank Level 100.0 %
Percentage Threshold
Generator Connection Configuration Wye (or Star) Connection
Generator Potential Transformer Primary 1 Volts
Winding Rating
Generator Potential Transformer 1 Volts
Secondary Winding Rating
Generator Current Transformer Primary 2500 Amps
Winding Rating
Generator Current Transformer Secondary 5 Amps
Winding Rating
Number of Generator Poles 4 Poles
Generator Rated Frequency 50 Hz
Generator Rated Voltage 400 Volts
Generator Rated Power 1020 kW
Generator Rated Apparent Power 1275 kVA
Maximum Generator Voltage Output Bias 15 %
Percentage
Customer Password Security Level to 3-Factory, Single Use
Reset Generator Energy Meters
Generator Definite Time Overcurrent 111 %
Warning Event Percentage Threshold
Generator Inverse Time Overcurrent 0.27 sec
Shutdown Event Time Multiplier
Generator Definite Time Overcurrent 115 %
Shutdown Event Percentage Threshold
Generator Definite Time Overcurrent 10.0 sec
Shutdown Event Notification Delay Time
Generator Inverse Time Over Current 115 %
Shutdown Event Threshold
Generator Inverse Definite Minimum Time Normal Inverse Curve
Curve Type Configuration
Generator Rated Current Multiplier 1.00
Maintenance Mode Definite Time Over Unavailable %
Current Shutdown Event Percentage
Generator Over Frequency Warning Event 105.0 %
Percentage Threshold
Generator Over Frequency Warning Event 10 sec
Notification Delay Time
Generator Over Frequency Shutdown 110.0 %
Event Percentage Threshold
Generator Over Frequency Shutdown 10 sec
Event Notification Delay Time
Generator Under Frequency Warning 95.0 %
Event Percentage Threshold
Generator Under Frequency Warning 10 sec
Event Notification Delay Time
Generator Under Frequency Shutdown 90.0 %
Event Percentage Threshold
Generator Under Frequency Shutdown 15 sec
Event Notification Delay Time
Generator Over Voltage Warning Event 105 %
Percentage Threshold
Generator Over Voltage Warning Event 10 sec
Notification Delay Time
Generator Over Voltage Shutdown Event 110 %
Percentage Threshold
Generator Over Voltage Shutdown Event 10 sec
Notification Delay Time
Generator Under Voltage Warning Event 90 %
Percentage Threshold
Generator Under Voltage Warning Event 10 sec
Notification Delay Time
Generator Under Voltage Shutdown Event 85 %
Percentage Threshold
Generator Under Voltage Shutdown Event 15 sec
Notification Delay Time
Generator Reactive Load Control 1.0 %
Proportional Gain Percentage
Generator Reactive Load Control Integral 1.0 %
Gain Percentage
Generator Reactive Load Control Power 1.00
Factor Level Configuration
Generator Reverse Power Warning Event 5 %
Percentage Threshold
Generator Reverse Power Warning Event 10 sec
Notification Delay Time
Generator Reverse Power Shutdown Event 10 %
Percentage Threshold
Generator Reverse Power Shutdown Event 10 sec
Notification Delay Time
Generator Reverse Reactive Power 5.00 %
Warning Event Percentage Threshold
Generator Reverse Reactive Power 20 sec
Warning Event Notification Delay Time
Generator Reverse Reactive Power 15.00 %
Shutdown Event Percentage Threshold
Generator Reverse Reactive Power 20 sec
Shutdown Event Notification Delay Time
Programmable Cycle Timer #1 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #1 Activation Deactivate
Day - Monday
Programmable Cycle Timer #1 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #1 Activation Deactivate
Day - Friday
Programmable Cycle Timer #1 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #1 Activation 0 min
Start Time
Programmable Cycle Timer #1 Active Time 1 min
Programmable Cycle Timer #1 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #1 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #2 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #2 Activation Deactivate
Day - Monday
Programmable Cycle Timer #2 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #2 Activation Deactivate
Day - Friday
Programmable Cycle Timer #2 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #2 Activation 0 min
Start Time
Programmable Cycle Timer #2 Active Time 1 min
Programmable Cycle Timer #2 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #2 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #3 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #3 Activation Deactivate
Day - Monday
Programmable Cycle Timer #3 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #3 Activation Deactivate
Day - Friday
Programmable Cycle Timer #3 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #3 Activation 0 min
Start Time
Programmable Cycle Timer #3 Active Time 1 min
Programmable Cycle Timer #3 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #3 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #4 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #4 Activation Deactivate
Day - Monday
Programmable Cycle Timer #4 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #4 Activation Deactivate
Day - Friday
Programmable Cycle Timer #4 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #4 Activation 0 min
Start Time
Programmable Cycle Timer #4 Active Time 1 min
Programmable Cycle Timer #4 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #4 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #5 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #5 Activation Deactivate
Day - Monday
Programmable Cycle Timer #5 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #5 Activation Deactivate
Day - Friday
Programmable Cycle Timer #5 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #5 Activation 0 min
Start Time
Programmable Cycle Timer #5 Active Time 1 min
Programmable Cycle Timer #5 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #5 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #6 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #6 Activation Deactivate
Day - Monday
Programmable Cycle Timer #6 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #6 Activation Deactivate
Day - Friday
Programmable Cycle Timer #6 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #6 Activation 0 min
Start Time
Programmable Cycle Timer #6 Active Time 1 min
Programmable Cycle Timer #6 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #6 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #7 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #7 Activation Deactivate
Day - Monday
Programmable Cycle Timer #7 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #7 Activation Deactivate
Day - Friday
Programmable Cycle Timer #7 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #7 Activation 0 min
Start Time
Programmable Cycle Timer #7 Active Time 1 min
Programmable Cycle Timer #7 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #7 Output #2 Inactive
Activation Configuration
Electronic Control Module Reduced Power Disabled
Mode Enable Status
Electronic Control Module Reduced Power 30 min
Mode Delay Time
Relay Output #1 Usage Type Command/Status Parameter
Relay Output #1 Command/Status Starter Motor Relay
Parameter Data Identification
Relay Output #2 Usage Type Disabled
Relay Output #3 Usage Type Disabled
Relay Output #4 Usage Type Command/Status Parameter
Relay Output #4 Command/Status Fuel Control Relay
Parameter Data Identification
Relay Output #5 Usage Type Command/Status Parameter
Relay Output #5 Command/Status Rated Speed
Parameter Data Identification
Relay Output #6 Usage Type Command/Status Parameter
Relay Output #6 Command/Status Common Shutdown
Parameter Data Identification
Relay Output #7 Usage Type Disabled
Relay Output #8 Usage Type Disabled
Maintenance Level 1 Cycle Interval Hours 500 hours
Maintenance Level 1 Cycle Interval Days 180
Customer Password Security Level to 3-Factory, Single Use
Reset Service Maintenance Interval
Programmable Trip Point Function #1 Disabled
Trigger Condition
Programmable Trip Point Function #1 0 %
Percentage Threshold
Programmable Trip Point Function #1 0 %
Hysteresis Percentage
Programmable Trip Point Function #1 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #1 Trip 0 sec
Deactivation Delay Time
Programmable Trip Point Function #2 Disabled
Trigger Condition
Programmable Trip Point Function #2 0 %
Percentage Threshold
Programmable Trip Point Function #2 0 %
Hysteresis Percentage
Programmable Trip Point Function #2 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #2 Trip 0 sec
Deactivation Delay Time
Programmable Trip Point Function #3 Disabled
Trigger Condition
Programmable Trip Point Function #3 0 %
Percentage Threshold
Programmable Trip Point Function #3 0 %
Hysteresis Percentage
Programmable Trip Point Function #3 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #3 Trip 0 sec
Deactivation Delay Time
Overview Screen Enable Status Disabled
Overview Screen Keypad Inactivity Delay 60.0 sec
Time
Generator/Utility Automatic Transfer Disabled
Enable Status
Loss of Utility Event Notification Delay 10.0 sec
Time
Generator to Utility Transfer Delay Time 3 min
Generator to Utility Fast Transfer Delay 10 sec
Time
Utility to Generator Transfer Failure 60 sec
Warning Event Threshold
Utility to Generator Transfer Failure 90 sec
Shutdown Event Threshold
Generator to Utility Transfer Failure 60 sec
Warning Event Threshold
Generator/Utility Automatic Transfer 0.0 sec
Unpowered Load Time
Generator Ready to Load Threshold 90.0 %
Percentage
Generator Ready to Load Delay Time 0.0 sec
Generator to Utility Transfer Mode Manual
Utility Breaker Maximum Closing Time 30 sec
Utility Breaker Maximum Opening Time 3 sec
Programmable Logic Feature Enable Disabled
Status
Programmable Logic Function File Name
Programmable Logic Function File Login
User Name
Programmable Logic Function File 01/01/1999 00:00:00
Download Time/Date
Programmable Logic Function File Modified 01/01/1999 00:00:00
Time/Date
Engine Serial Number Not Programmed
Display Pressure Units Configuration bar
Display Temperature Units Configuration Degrees Centigrade (Celsius)
Display Volume Units Configuration liters

Lifetime:Total Operating Hours vs Generator Real Load Percentage - EMCP 4.2B


Generator Real Load hours %
Percentage( % )
0.0-29.9 42.82 97.39
30.0-89.9 0.00 0.00
90.0-99.9 1.00 2.27
100.0-110.0 0.15 0.34
>110.0 0.00 0.00

Product Link Elite (LY700123)


Parameter Value
Product ID LY700123
Machine Serial Number LY700123
Equipment ID
ECM Part Number 4590786-01
ECM Serial Number 0725F037TR
Software Group Part Number 5161714-00
Software Group Release Date Jun2016
Software Group Description VIMS_TELEMATICS_2016_06_23
Application Software Part Number 5375536-00
Cellular Device ECM Serial Number NA
Cellular Device ECM Hardware Part Number NA
Cellular Radio Module Software Part Number NA
Satellite Device ECM Serial Number NA
Satellite Device ECM Hardware Part Number NA
Satellite Radio Module Software Part Number NA

Logged Diagnostic Codes [Total Operating Hours = 117 hours] - Product Link Elite (LY700123)
Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [Total Operating Hours = 117 hours] - Product Link Elite (LY700123)
Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - Product Link Elite (LY700123)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - Product Link Elite (LY700123)


Code Description
No Active
Event Codes

Current Totals - Product Link Elite (LY700123)


Description Value Unit
Total Operating Hours 117.6 hours
Total Distance 0.00 km

Configuration - Product Link Elite (LY700123)


Description Value Unit
Product ID LY700123
Equipment ID
External Service Lamp Installation Installed
Configuration
External Service Lamp Display Mode No Snapshot Notice
Setting
Telemetry Port Selection Disabled
TMAC Protocol Port Selection Invalid Data
Tire Monitoring System Installation Status Unavailable
CAT Data Link Module Identifier Gateway #1
Configuration
Machine Serial Number LY700123
Mining Aftermarket System Installation Unavailable
Status
Maintenance Mode Off
Machine Payload Control System Not Installed
Installation Status
Road Analysis System Installation Status Not Installed
Tire Analysis System Installation Status Not Installed
Tire Analysis System Temporary Not Installed
Installation Status
Tire Analysis System Temporary 15000 min
Installation Time Remaining
Security System Tamper Resistant Not Installed
Configuration

You might also like