Professional Documents
Culture Documents
0
Product Status Report
28/1/2023 10:47
EMCP 3.3
Parameter Value
ECM Part Number 3007647-03
ECM Serial Number 0841B155TB
Software Group Part Number 3774431-00
Software Group Release Date MAR2011
Software Group Description L2 11_0 Standard -- Spanish, 2.2.2 Prod,
7April2011
Logged Diagnostic Codes [SHM: 6282 RTC: 27/1/2038 09:51:43] - EMCP 3.3
Code Description Occ. SHM First SHM Last RTC First RTC Last
1231-11 J1939 Network #2 : Other 39 2910:00:53 5806:49:32 20/4/2022 10/10/2022
Failure Mode 04:34:14 19:29:13
1383-11 Engine was Shut Down 2 1358:38:32 5806:03:44 19/1/2022 8/10/2022
Hot : Other Failure Mode 06:31:57 17:13:15
Logged Event Codes [SHM: 6282 RTC: 27/1/2038 09:51:44] - EMCP 3.3
Code Description Occ. SHM First SHM Last RTC First RTC Last
100-17 Engine Oil Pressure : Low 1 6253:07:10 6253:07:10 13/11/2022 13/11/2022
- least severe (1) 10:51:14 10:51:14
110-17 Engine Coolant 99 6253:07:11 6254:22:30 13/11/2022 18/11/2022
Temperature : Low - least 15:00:44 01:18:23
severe (1)
168- 0 Battery Potential / Power 1 6255:01:30 6255:01:30 1/12/2022 1/12/2022
Input #1 : High - most 16:50:27 16:50:27
severe (3)
168-15 Battery Potential / Power 30 217:25:30 6255:01:30 19/1/2016 1/12/2022
Input #1 : High - least 20:53:07 16:50:55
severe (1)
168-17 Battery Potential / Power 77 466:13:30 6281:51:08 9/3/2017 24/1/2023
Input #1 : Low - least 21:00:13 18:30:06
severe (1)
190- 1 Engine Speed : Low - 24 554:35:08 5806:49:30 25/8/2017 9/10/2022
most severe (3) 16:49:51 13:03:17
190-17 Engine Speed : Low - 59 554:34:23 5806:49:30 25/8/2017 9/10/2022
least severe (1) 16:49:06 13:03:17
970-31 Engine Auxiliary Engine 26 6253:20:42 6280:47:31 14/11/2022 26/12/2022
Shutdown Switch 15:25:44 21:04:35
2436- 1 Generator Average AC 8 1070:10:30 5806:40:30 15/10/2020 9/10/2022
Frequency : Low - most 06:44:34 12:46:24
severe (3)
2436-17 Generator Average AC 29 5716:30:42 6254:48:44 2/10/2022 19/11/2022
Frequency : Low - least 20:49:29 19:28:46
severe (1)
2440- 1 Generator Average Line- 48 428:51:19 6254:48:59 10/1/2017 19/11/2022
Line AC RMS Voltage : 17:19:11 19:29:01
Low - most severe (3)
2440-17 Generator Average Line- 31 5716:31:13 6254:48:45 2/10/2022 19/11/2022
Line AC RMS Voltage : 20:50:00 19:28:47
Low - least severe (1)
2448-15 Generator Average AC 2 1089:08:29 5807:11:47 14/3/2021 10/10/2022
RMS Current : High - 07:34:57 19:51:34
least severe (1)
2452- 1 Generator Total Real 2 3702:47:22 5798:23:05 1/7/2022 8/10/2022
Power : Low - most 11:47:34 09:00:01
severe (3)
2648-31 Maintenance Lamp 99 1074:56:43 5716:37:30 9/11/2020 2/10/2022
21:48:58
4003-31 Battery Charger Failure 51 6253:16:28 6281:52:30 14/11/2022 24/1/2023
14:18:56 19:21:32
4007-31 Generator Control not in 99 0:00:00 16:37:48 2/6/2011 10/10/2013
Automatic 11:44:36 07:11:59
4028-31 Earth Fault 1 6265:40:30 6265:40:30 10/12/2022 10/12/2022
11:29:53 11:29:53
Active Diagnostic Codes [SHM: 6282 RTC: 27/1/2038 09:51:44] - EMCP 3.3
Code Description Occ.
No Active
Diagnostic
Codes
Active Event Codes [SHM: 6282 RTC: 27/1/2038 09:51:44] - EMCP 3.3
Code Description Occ.
2648-31 Maintenance Lamp 99
4007-31 Generator Control not in Automatic 99
Logged Event Codes [Diagnostic Clock = 6276 hours] - C27 Genset (MJE02607)
Code Description Occ. First Last
E198 (1) Low Fuel Pressure 73 5761 6248