Detailed Performance Summary For DS - 30XA200

Project: Unimed Concórdia 03/27/2020


Prepared By: 06:42

PackagedChillerReport:DoNotEdit;

AquaForce TM Air-Cooled Screw Chiller

Unit Information Integrated Pump Information


Tag Name: DS - 30XA200 No Pump Selected
Model Number: 30XA200
Condenser Type: Air Cooled Accessories and Installed Options
Compressor Type: Screw Freeze Protection
Nameplate Voltage: 380-3-60 V-Ph-Hz Control Transformer
Quantity: 1 Al Fin/Cu Tube, Pre-Coated
Manufacturing Source: Charlotte, NC USA Wye-Delta Starter
ASHRAE 90.1: 2013/2016, 2010, 2007 Dual Point
Refrigerant: R-134a BACnet Translator Control
Minimum Capacity: 15,00 % Coil Trim Panels
Shipping Weight: 6135 kg Touch Pilot Display
Operating Weight: 6220 kg Std SCCR 5 k Current Rating (All Voltages)
Unit Length: 7188 mm
Unit Width: 2253 mm Electrical Information
Unit Height: 2297 mm Unit Voltage: 380-3-60 V-Ph-Hz
Minimum Outdoor Operating Temp: 0,0 °C Connection Type: Dual Point
Minimum Voltage: 342 Volts
Performance Information Maximum Voltage: 418 Volts
Cooling Capacity: 688,1 kW
Total Compressor Power: 204,1 kW Electrical Electrical
Total Fan Motor Power: 15,82 kW Amps Circuit 1 Circuit 2
Total Unit Power (without pump): 219,9 kW MCA 246,0 246,0
Efficiency (without pump) (COPR): 3,129 kW/kW MOCP 400,0 400,0
ICF 483,8 483,8
Evaporator Information Rec Fuse Size 300,0
Fluid Type: Fresh Water
Fouling Factor: 0,0176 (sqm-K)/kW
Number of Passes: 2
Leaving Temperature: 7,00 °C
Entering Temperature: 14,00 °C
Fluid Flow: 23,44 L/s
Fluid Flow Min: 14,07 L/s
Fluid Flow Max: 56,28 L/s
Pressure Drop: 26,1 kPa

Condenser Information
Altitude: 0,000 m
Number of Fans: 12
Total Condenser Fan Air Flow: 52.670 L/s
Entering Air Temperature: 35,0 °C

Packaged Chiller Builder NACO 3.59f Page 1 of 3


Detailed Performance Summary For DS - 30XA200
Project: Unimed Concórdia 03/27/2020
Prepared By: 06:42

Integrated Part Load Value (AHRI)


IPLV.IP: 4,305 kW/kW

Unit Performance
Percent of Full Load Capacity, % 100,00 75,00 50,00 25,00
Percent of Full Load Power, % 100,00 60,93 33,51 16,13
Unloading Sequence B B B B
Cooling Capacity, kW 680,2 510,1 340,1 170,0
Total Unit Power, kW 218,7 133,3 73,30 35,27
Efficiency (COPR), kW/kW 3,110 3,828 4,640 4,821
Evaporator Data
Fluid Entering Temperature, °C 12,22 10,83 9,44 8,05
Fluid Leaving Temperature, °C 6,67 6,67 6,67 6,67
Fluid Flow Rate, L/s 29,18 29,18 29,18 29,18
Fouling Factor, (sqm-K)/kW 0,0176 0,0176 0,0176 0,0176
Condenser Data
Entering Air Temperature, °C 35,0 26,7 18,3 12,8

Nonstandard Part-Load Value


NPLV.IP: 4,330 kW/kW

Unit Performance
Percent of Full Load Capacity, % 100,00 75,00 50,00 25,00
Percent of Full Load Power, % 100,00 60,72 33,65 16,08
Unloading Sequence B B B B
Capacity, kW 688,1 516,1 344,0 172,0
Total Unit Power, kW 219,9 133,5 73,99 35,37
Efficiency (COPR), kW/kW 3,129 3,865 4,650 4,863
Evaporator Data
Fluid Entering Temperature, °C 14,00 12,24 10,49 8,75
Fluid Leaving Temperature, °C 7,00 7,00 7,00 7,00
Fluid Flow Rate, L/s 23,44 23,44 23,44 23,44
Fouling Factor, (sqm-K)/kW 0,0176 0,0176 0,0176 0,0176
Condenser Data
Entering Air Temperature, °C 35,0 26,7 18,4 12,8

Sound power measured in accordance with ANSI/AHRI Standard 370-2015.

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which
is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at
www.ahridirectory.org.

The NPLV is not an AHRI 550/590 metric and is not certified. It is based on ambient temperature varying linearly from the full
load ambient to 55 F at 0% load.

Packaged Chiller Builder NACO 3.59f Page 2 of 3


Detailed Performance Summary For DS - 30XA200
Project: Unimed Concórdia 03/27/2020
Prepared By: 06:42

Unit Parameters
Tag Name: DS - 30XA200
Model Number: 30XA200
Condenser Type: Air Cooled
Compressor Type: Screw
Chiller Nameplate Voltage: 380-3-60 V-Ph-
Hz
Quantity: 1
Manufacturing Source: Charlotte, NC USA
Refrigerant: R-134a
Shipping Weight: 6135 kg
Operating Weight: 6220 kg
Unit Length: 7188 mm 1 - Chiller Height Above Ground
Unit Width: 2253 mm 2 - Horizontal Distance From Chiller to Receiver
Unit Height: 2297 mm 3 - Receiver Height Above Ground
(See Note 3)

Accessories and Installed Options


Freeze Protection BACnet Translator Control
Control Transformer Coil Trim Panels
Al Fin/Cu Tube, Pre-Coated Touch Pilot Display
Wye-Delta Starter Std SCCR 5 k Current Rating (All Voltages)
Dual Point

Acoustic Information
Table 1. A-Weighted Sound Power Levels (dB re 1 picowatt). See note #1.

Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall


100% Load --- 69 84 92 95 99 94 91 81 102
75% Load --- 63 79 93 92 101 94 86 78 103
50% Load --- 61 77 90 89 98 92 83 75 100
25% Load --- 59 74 89 89 98 91 83 75 100

Table 2. A-Weighted Sound Pressure Levels (dB re 20 micropascals) calculated based upon user defined input
for dimensions 1, 2 and 3 as shown in above diagram. See note #2 and #3.

Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall


100% Load --- 41 56 63 67 70 66 63 53 74
75% Load --- 35 51 64 64 73 66 58 49 75
50% Load --- 33 49 62 61 70 63 55 46 72
25% Load --- 31 46 61 61 70 63 55 46 72

Notes: (1) Measurements performed in accordance with AHRI Standard 370-2015 for air cooled Chillers.
(2) Chiller is assumed to be a point source on a reflecting plane.
(3) Without user defined input, the default dimensions used to construct Table 2 are as follows:
1 - Chiller Height Above Ground = 0,0 m
2 - Horizontal Distance From Chiller to Receiver = 9,1 m
3 - Receiver Height Above Ground = 0,9 m

Packaged Chiller Builder NACO 3.59f Page 3 of 3