Air Cooled Screw Chiller Performance

Datasheet
Net Cooling Nominal Power
Unit Tag Qty Model No Refrigerant Type
Capacity (ton.R) Volts-Ph-Hz
CH-1 10 YVAA0490KZV40BAVSXX 482.8 380-3-60.0 R134a

Evaporator Data Evaporator Data (Cont.) Performance Data


EWT (°F) 54.00 Fluid Volume (USGAL) 130.0 EER (Btu/W∙h) 9.123
Min. Design Flow Rate
LWT (°F) 44.00 470.0 IPLV.IP (Btu/W∙h) 17.30
(USGPM)*
Design Flow Rate (USGPM) 1156 Max. Flow Rate (USGPM) 1870 NPLV.IP (Btu/W∙h) 17.33
Total Press. Drop (ft H2O) 24.0 Condenser Data Physical Data
Fluid Water Ambient Temp. Design (°F) 95.0 Rigging Wt. (lb) 23627
Fouling Factor (h.ft².F/Btu) 0.000 Altitude (ft) 0.000 Operating Wt. (lb) 24712
VSD Screw - Semi
Number Passes 2 Compressor Type Refrigerant Charge (lb) 352.7
Hermetic

Electrical Data
Circuit 1 2 3 4
Compressor kW 301.7 300.8
Compressor RLA 483 482
Fan QTY/FLA (each) 10 / 3 10 / 3

Single Point
Min. Circuit Ampacity 1152
Max. Fuse / CB Rating (A) 1600
Unit Short Circuit Withstand (STD) 30 [kA]
Wires Per Phase 4
Wire Range (Lug Size) 1/0 - 750 kcmil
Operating Condition Electrical Data
Control kVA 3 Compressor kW 602.5
Total kW 635.1

Notes:

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Using Vapor
Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and
AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at
www.ahridirectory.org. Auxiliary components included in total KW - Oil heaters, Chiller controls.
Auxiliary power is already included in the compressor and fan power

Min DSD (Factory Purpose/Use only): 80 psig


Country of Origin: Mexico,United States, Saudi Arabia,China
Use Copper Conductors only
Displacement Power Factor refers to compressor only. Unit Power Factor depends on fan option
selected. Calculated value is available by request.

Minimum and maximum evaporator flow information are for full load ratings with Water.
Compressor Type: V, Sound Kit Type: X, Orifice Type: B, Sound Optimization: No, Max Fan Speed: 60, Max Compressor Speed: 210, VSD Type: V,
Safety Code: L
Actuated suction service valves ARE NOT selected
Minimum Chilled Water Flow Rate is for full load selections; Variable Primary Flow ratings as low as 50% of the minimum are permitted. Glycol limits are
higher. To obtain minimum flow with Variable Primary Flow, run rating with Variable Primary Flow Partload Type.

MLP Effective Date:10/15/2023 Mega mall


Generated on2023-12-31 E.21.9.30329.0-D.98.0009(REV. v8_45.idd) Datasheet Spec
Unit Folder: CH-1 Software Version: YW21.09 Page_1_of_2
Air Cooled Screw Chiller Performance
Datasheet

Part Load Rating Data


Unit Efficiency
Load % Ambient (°F) Capacity (ton.R) Total kW
(Btu/W∙h)
100 95.0 482.8 635.1 9.123
75 80.1 362.1 316.0 13.75
50 65.1 241.4 149.0 19.44
25 55.0 120.7 63.68 22.74

Sound Power Levels (In Accordance with AHRI 370)


Ambient 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
Load % LWA
(°F) (dB) (dB) (dB) (dB) (dB) (dB) (dB) (dB)
100 95.0 99 100 100 107 104 101 95 89 109
75 80.1 99 100 100 101 98 91 89 84 102
50 65.1 96 95 96 97 95 88 86 84 99
25 55.0 92 91 93 94 90 84 82 81 95

Note: Unit is equipped with Low Sound Fans with Variable Speed Control.
Measurement of sound pressure used to obtain the sound power data presented is based on AHRI-370.
Air-cooled chillers are rated in terms of sound power not sound pressure. Johnson Controls provides estimates of sound pressure, but this is not the
rating metric.
For an air-cooled chiller, sound pressure calculated from sound power varies depending on how the chiller is assumed to behave, i.e. the radiation
model. In other words, determining sound pressure from sound power requires making assumptions that result in different answers at a given distance
from the chiller. The environment also influences sound pressure in the field installation. Sound pressure estimation radiation models pertaining to air-
cooled chillers include the ‘traditional’ hemispherical model, parallelepiped model and equivalent hemispherical model.
Regarding sound power, Johnson Controls references tolerance limits based on ASHRAE guidelines. These are +/- 6dB in the 63Hz octave band, +/-
4dB in all other octave bands and +/- 3dB for the overall dBA.
Tolerance limits are based on uncertainties associated with:
1. Measurement Test Procedure
2. Repeatability
3. Production / Manufacturing Variability
Standard deviation associated with air-cooled chiller sound data is a measure of spread i.e. it indicates the range of probability of sound levels. Note
that for operating conditions other than AHRI’s Standard Rating Condition, higher levels of uncertainty can be expected.
Lead times for factory performance testing depend on test laboratory availability. Please confirm with Johnson Controls Customer Service.

Performance at AHRI Conditions


Evaporator Data Condenser Data Performance Data
EWT (°F) 54.00 Ambient Temp. (°F) 95.0 EER (Btu/W∙h) 9.092
LWT (°F) 44.00 Altitude (ft) 0.000 IPLV.IP (Btu/W∙h) 17.30
Net Cooling Capacity
Flow Rate (USGPM) 1145 478.5
(ton.R)
Pressure Drop (ft H2O) 23.6
Fluid Water
Fouling Factor (h.ft².F/Btu) 0.000100
Fluid Volume (USGAL) 130.0

Note: Unit rated at design condition compressor frequency.

Part Load Rating Data at AHRI Conditions


Unit Efficiency
Load % Ambient (°F) Capacity (ton.R) Total kW
(Btu/W∙h)
100 95.0 478.5 631.5 9.092
75 80.0 358.9 314.0 13.71
50 65.0 239.2 147.9 19.41
25 55.0 119.6 63.41 22.64

MLP Effective Date:10/15/2023 Mega mall


Generated on2023-12-31 E.21.9.30329.0-D.98.0009(REV. v8_45.idd) Datasheet Spec
Unit Folder: CH-1 Software Version: YW21.09 Page_2_of_2