You are on page 1of 5

Page 1 of 5

EST 2010B v1.0


Product Status Report

03/04/2016 11:19 SA

Product Status Report


Parameter Value
Engine Serial Number MGBF7140N02623A
Equipment ID NOT PROGRAMMED
Comments

2506-E15 (MGBF7140N02623A)
Parameter Value
Equipment ID NOT PROGRAMMED
Engine Serial Number MGBF7140N02623A
ECM Serial Number 19556204JL
Software Group Part Number 4340501-00
Software Group Release Date OCT13
Software Group Description 2506A TAG2 50Hz

Critical Events
Description Start Time Elapsed Extreme Average
No Critical Events.

Logged Diagnostic Codes [ECM Diagnostic Clock = 0,6600 hours]


Code Description Occ. First Last
4- 5 Cylinder #4 Injector open circuit 1 0 0

Logged Event Codes [ECM Diagnostic Clock = 0,6600 hours]


Code Description Occ. First Last
No Logged Events

file://E:\may phat dien\FGWILSON\EST\ECM\ECMP550P1 YURTEC\ECMM2P550P1yurtec.xml 18/04/2016


Page 2 of 5

Active Diagnostic Codes


Code Description
No Active Codes

Active Event Codes


Code Description
No Active Events

Current Totals
Description Value Unit
Total Engine Operating Hours 1 hours

Configuration
Description Value Unit
Equipment ID NOT PROGRAMMED
Engine Serial Number MGBF7140N02623A
ECM Serial Number 19556204JL
Software Group Part Number 4340501-00
Software Group Release Date OCT13
Software Group Description 2506A TAG2 50Hz
Rating Number 2
Rated Frequency 50 Hz
Rated Genset Speed 1500 RPM
Rated Real Genset Power Unavailable Parameter
Rated Apparent Genset Power 550 kVA
Engine Rating Application Type Standby
External Speed Selection Switch Installed Disabled
Engine Acceleration Rate 500 RPM/s
Droop/Isochronous Switch Installed Enabled
Droop/Isochronous Selection Isochronous
Engine Speed Droop 4,0 %
Digital Speed Control Installed Not Installed
Speed Control Minimum Speed 125 RPM
Speed Control Maximum Speed 125 RPM

file://E:\may phat dien\FGWILSON\EST\ECM\ECMP550P1 YURTEC\ECMM2P550P1yurtec.xml 18/04/2016


Page 3 of 5

Digital Speed Control Ramp Rate Unavailable RPM/s


Crank Terminate RPM 400 RPM
Desired Speed Input Arrangement 0-5 VDC Input
Fuel Enable Input Configuration Switch to Ground
Critical Override Switch Installed Not Installed
Emergency Shutdown Override Input Configuration Switch to Ground
Governor Gain Factor #1 13107
Governor Minimum Stability Factor #1 1049
Governor Maximum Stability Factor #1 2097
Full Load Setting (FLS) 42
Full Torque Setting (FTS) -49
Customer Password 1 ********
Customer Password 2 ********
Total Tattletales 1

Lifetime: Time vs Engine Coolant Temperature


Engine Coolant Temperature( Deg C ) hours %
<50 0,05 16,67
50-54 0,00 0,00
55-59 0,00 0,00
60-64 0,00 0,00
65-69 0,00 0,00
70-74 0,00 0,00
75-79 0,00 0,00
80-84 0,00 0,00
85-89 0,20 66,67
90-94 0,05 16,67
95-99 0,00 0,00
100-104 0,00 0,00
105-109 0,00 0,00
110-114 0,00 0,00
115-119 0,00 0,00
>120 0,00 0,00

Lifetime: Time vs Intake Manifold Air Temperature


Intake Manifold Air Temperature( Deg C ) hours %

file://E:\may phat dien\FGWILSON\EST\ECM\ECMP550P1 YURTEC\ECMM2P550P1yurtec.xml 18/04/2016


Page 4 of 5

<40 0,00 0,00


40-44 0,00 0,00
45-49 0,00 0,00
50-54 0,05 100,00
55-59 0,00 0,00
60-64 0,00 0,00
65-69 0,00 0,00
70-74 0,00 0,00
75-79 0,00 0,00
80-84 0,00 0,00
85-89 0,00 0,00
90-94 0,00 0,00
95-99 0,00 0,00
>100 0,00 0,00

Lifetime: Time vs Intake Manifold Pressure (Gauge)


Intake Manifold Pressure (Gauge)( kPa ) hours %
<80 0,00 0,00
80-89 0,00 0,00
90-99 0,00 0,00
100-109 0,00 0,00
110-119 0,00 0,00
120-129 0,00 0,00
130-139 0,00 0,00
140-149 0,00 0,00
150-159 0,00 0,00
160-169 0,00 0,00
170-179 0,00 0,00
180-189 0,00 0,00
190-199 0,00 0,00
>200 0,05 100,00

Lifetime: Total Occurrences vs Actual Engine Speed


Actual Engine Speed( RPM ) %
<2500 0,00 0,00
2500-2599 0,00 0,00

file://E:\may phat dien\FGWILSON\EST\ECM\ECMP550P1 YURTEC\ECMM2P550P1yurtec.xml 18/04/2016


Page 5 of 5

2600-2699 0,00 0,00


2700-2799 0,00 0,00
2800-2899 0,00 0,00
2900-2999 0,00 0,00
3000-3099 0,00 0,00
3100-3199 0,00 0,00
3200-3299 0,00 0,00
>3300 0,00 0,00

Lifetime: Time vs Actual Engine Speed And Engine Load Factor


1100- 1300- 1500- 1700- 1900- 2100-
RPM <1100 >2300 Total
1299 1499 1699 1899 2099 2299
%
<50 0,00 0,00 0,00 25,00 0,00 0,00 0,00 0,00 25,00
50-
0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00
60
60-
0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00
70
70-
0,00 0,00 0,00 25,00 0,00 0,00 0,00 0,00 25,00
80
80-
0,00 0,00 0,00 25,00 0,00 0,00 0,00 0,00 25,00
90
>90 0,00 0,00 25,00 0,00 0,00 0,00 0,00 0,00 25,00
Total 0,00 0,00 25,00 75,00 0,00 0,00 0,00 0,00 100,00

Injector Trim Calibration


Injector Serial Number File Version
Injector1 000000005A5320240830 0
Injector2 000000005A532023322F 0
Injector3 000000005A532023695F 0
Injector4 000000005A5320234658 0
Injector5 000000005A53202392AD 0
Injector6 000000005A5320241401 0

file://E:\may phat dien\FGWILSON\EST\ECM\ECMP550P1 YURTEC\ECMM2P550P1yurtec.xml 18/04/2016