MUD FLOW SENSOR 97TA0006


F U
IN ISS

TROUBLESHOOTING
THIS TABLE CONTAINS INSTRUCTIONS NECESSARY TO
EFFECTIVELY TROUBLESHOOT THE FLOW SENSOR.

MALFUNCTION ISOLATION CHART


MALFUNCTION PROBABLE CAUSE CORRECTIVE ACTION
No 24 VDC Supply,
Check P/S / Barrier Replace Power Supply/ Barrier
No Signal From
Check Wire From Display Replace Wiring
Return Flow Sensor Thru Jct Box to Sensor

Broken Proximity Sensor Replace Proximity Sensor

Signal Does Not Change Jammed Paddle Clean Out Flowline

When Flow Changes Loose/ Disconnected


Tighten Cam Mount Screw
Signal Cam
Signal Does Not Go
To Zero At No-Flow Cuttings in Flowline Clean, Flush out Flowline
(Check Calibration)
Incorrect Calibration Recalibrate 0 %

Proximity Sensor Reset Proximity Sensor


Set Incorrectively And Recalibrate
Target Cam Reset Target Cam
Loose/Set Incorrectively And Recalibrate
Signal Does Not Go
To 100% At Full-Flow Incorrect Calibration Recalibrate 100%
(Check Calibration)
Proximity Sensor Reset Proximity Sensor
Set Incorrectively And Recalibrate
Target Cam Reset Target Cam
Loose/Set Incorrectively And Recalibrate