IEC Curves

Calculation for Inverse Time Curves


SI Curve Time Mult EI Curve Time Mult VI Curve Time Mult LTI Curve
Plug Set Plug Set Plug Set Plug Set
1.5 0.00 1.5 0.00 1.5 0.00 1.5
2 0.00 2 0.00 2 0.00 2
3 0.00 3 0.00 3 0.00 3
4 0.00 4 0.00 4 0.00 4
5 0.000 5 0.000 5 0.000 5
6 0.000 6 0.000 6 0.000 6
7 0.000 7 0.000 7 0.000 7
8 0.000 8 0.000 8 0.000 8
9 0.000 9 0.000 9 0.000 9
10 0.000 10 0.000 10 0.000 10

Group # 2
Calculation for Inverse Time Curves
SI Curve Time Mult 0.000 EI Curve Time Mult 0.000 VI Curve Time Mult 0.080 LTI Curve
Plug Set Plug Set Plug Set Plug Set
2 0.00 2 0.00 2 1.08 2
3 0.00 3 0.00 3 0.54 3
4 0.00 4 0.00 4 0.36 4
5 0.000 5 0.000 5 0.270 5
6 0.000 6 0.000 6 0.216 6
7 0.000 7 0.000 7 0.180 7
8 0.000 8 0.000 8 0.154 8
9 0.000 9 0.000 9 0.135 9
10 0.000 10 0.000 10 0.120 10

Group # 3
Calculation for Inverse Time Curves
SI Curve Time Mult 0.000 EI Curve Time Mult 0.000 VI Curve Time Mult 0.000 LTI Curve
Plug Set Plug Set Plug Set Plug Set
2 0.00 2 0.00 2 0.00 2
3 0.00 3 0.00 3 0.00 3
4 0.00 4 0.00 4 0.00 4
5 0.000 5 0.000 5 0.000 5
6 0.000 6 0.000 6 0.000 6
7 0.000 7 0.000 7 0.000 7
8 0.000 8 0.000 8 0.000 8
9 0.000 9 0.000 9 0.000 9
10 0.000 10 0.000 10 0.000 10

SI Curve Time Mult 0.100 EI Curve Time Mult VI Curve Time Mult LTI Curve
Plug Set Plug Set Plug Set Plug Set
2 1.00 2 0.00 2 0.00 2
4 0.50 4 0.00 4 0.00 4
6 0.384 6 0.000 6 0.000 6
8 0.330 8 0.000 8 0.000 8

Page 1
Test Values for IDMT
IEC Curves

10 0.297 10 0.000 10 0.000 10

Page 2
Test Values for IDMT
IEC Curves

Time Mult

0.0
0.0
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Time Mult 0.000

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Time Mult 0.000

0.0
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Time Mult

0.0
0.00
0.00
0.00

Page 3
Test Values for IDMT
IEC Curves

0.00

Page 4
Test Values for IDMT
CDG Curves

CDGx1 Inverse Time Curves


1.3 Sec CDG 1 ( 1.3 sec )
Starting current = 103-105%. Closing current = 115% or 117% if fitted with mechanical operation indicator. Reset current = 90%
Column B Column C Column D
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 10.000 Column E Column F Column G
Reset time = 4 Secs at TM 1.0
Column H Column I Column J
2 0.101 0.181 0.262 0.343 0.424 0.504 0.585 0.674 0.763 0.851 0.940 1.035 1.130 1.225 1.320 1.415 1.510 1.605 1.700 1.910 2.120 2.325 2.530 2.740 2.950 3.175 3.400 3.625 3.850 Column K Column L Column M
3 0.091 0.146 0.202 0.258 0.314 0.369 0.425 0.483 0.540 0.598 0.655 0.716 0.777 0.837 0.898 0.959 1.019 1.080 1.140 1.265 1.390 1.530 1.670 1.810 1.950 2.088 2.225 2.355 2.485 1.000 Column N Column O Column P
4 0.082 0.127 0.173 0.218 0.263 0.308 0.354 0.403 0.452 0.501 0.550 0.601 0.651 0.702 0.752 0.802 0.851 0.901 0.950 1.055 1.160 1.268 1.375 1.483 1.590 1.700 1.810 1.915 2.020 Column Q Column R Column S

Time
5 0.078 0.120 0.162 0.203 0.245 0.286 0.328 0.371 0.414 0.457 0.500 0.544 0.589 0.633 0.677 0.720 0.764 0.807 0.850 0.940 1.030 1.123 1.215 1.313 1.410 1.505 1.600 1.688 1.775 Column T Column U Column V
6 0.075 0.114 0.153 0.192 0.231 0.270 0.309 0.348 0.387 0.426 0.465 0.505 0.546 0.586 0.626 0.665 0.703 0.742 0.780 0.865 0.950 1.035 1.120 1.203 1.285 1.368 1.450 1.535 1.620 Column W Column X Column Y
0.100
7 0.072 0.109 0.145 0.182 0.218 0.255 0.291 0.328 0.365 0.401 0.438 0.476 0.513 0.551 0.588 0.626 0.664 0.701 0.739 0.815 0.890 0.968 1.045 1.123 1.200 1.280 1.360 1.435 1.510 Column Z Column AA Column AB
2 3 4 5 6 7 8 9 10
8 0.069 0.104 0.139 0.174 0.209 0.244 0.279 0.314 0.349 0.384 0.419 0.455 0.491 0.526 0.562 0.597 0.631 0.666 0.700 0.772 0.844 0.917 0.990 1.063 1.135 1.205 1.275 1.350 1.425 Column AC Column AD Column AE
9 0.068 0.102 0.135 0.169 0.202 0.236 0.269 0.302 0.336 0.369 0.402 0.437 0.471 0.506 0.540 0.574 0.609 0.643 0.677 0.744 0.810 0.878 0.945 1.013 1.080 1.150 1.220 1.290 1.360
0.010
10 0.065 0.098 0.130 0.163 0.195 0.228 0.260 0.293 0.325 0.358 0.390 0.423 0.455 0.488 0.520 0.552 0.584 0.616 0.648 0.714 0.779 0.845 0.910 0.975 1.040 1.105 1.170 1.235 1.300
Plug setting multiplier

CDGx1 Inverse Time Curves


2.7 Sec Starting Current = 95-105%. Closing current = 100% .Reset time = 4 - 9 Secs at TM 1.0 . Reset current = 90% 10.000
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 1 ( 2.7 sec )
Reset time = 9 Secs at TM 1.0
2 0.390 0.59 0.790 0.990 1.190 1.390 1.590 1.800 2.010 2.220 2.430 2.643 2.855 3.068 3.280 3.490 3.700 3.910 4.120 4.535 4.950 5.345 5.740 6.120 6.500 6.940 7.380 7.790 8.200
3 0.281 0.42 0.552 0.688 0.824 0.959 1.095 1.236 1.378 1.519 1.660 1.795 1.930 2.065 2.200 2.340 2.480 2.620 2.760 3.030 3.300 3.540 3.780 4.040 4.300 4.600 4.900 5.125 5.350
4 0.232 0.34 0.450 0.559 0.668 0.777 0.886 1.002 1.118 1.234 1.350 1.458 1.565 1.673 1.780 1.895 2.010 2.125 2.240 2.455 2.670 2.875 3.080 3.298 3.515 3.753 3.990 4.165 4.340 Column B Column C Column D
5 0.205 0.30 0.395 0.490 0.585 0.680 0.775 0.875 0.975 1.075 1.175 1.269 1.363 1.456 1.550 1.650 1.750 1.850 1.950 2.138 2.325 2.503 2.680 2.875 3.070 3.280 3.490 3.645 3.800 Column E Column F Column G
1.000

Time
6 0.185 0.27 0.355 0.440 0.525 0.609 0.694 0.787 0.880 0.972 1.065 1.149 1.233 1.316 1.400 1.490 1.580 1.670 1.760 1.935 2.110 2.265 2.420 2.600 2.780 2.965 3.150 3.305 3.460 Column H Column I Column J
Column K Column L Column M
7 0.170 0.25 0.328 0.406 0.485 0.564 0.643 0.727 0.810 0.894 0.977 1.055 1.134 1.212 1.290 1.374 1.458 1.541 1.625 1.783 1.940 2.090 2.240 2.395 2.550 2.730 2.910 3.055 3.200
Column N Column O Column P
8 0.154 0.23 0.304 0.379 0.454 0.530 0.605 0.681 0.757 0.834 0.910 0.985 1.060 1.135 1.210 1.288 1.365 1.443 1.520 1.670 1.820 1.960 2.100 2.245 2.390 2.555 2.720 2.860 3.000
Column Q Column R Column S
9 0.143 0.21 0.286 0.358 0.429 0.501 0.572 0.643 0.714 0.784 0.855 0.926 0.996 1.067 1.137 1.209 1.281 1.353 1.425 1.573 1.720 1.853 1.985 2.128 2.270 2.415 2.560 2.695 2.830
Column T Column U Column V
10 0.134 0.20 0.270 0.338 0.407 0.475 0.543 0.610 0.677 0.743 0.810 0.876 0.943 1.009 1.075 1.146 1.218 1.289 1.360 1.494 1.627 1.759 1.890 2.025 2.160 2.295 2.430 2.565 2.700 Column W Column X Column Y
0.100 Column Z Column AA Column AB
CDGx1 Inverse Time Curves 2 3 Plug
4 setting
5 Column 7AC
multiplier
6 8 Column
9 10AD Column AE
3.0 Sec Starting Current = 103-105%. Closing current = 115% or 117% if fitted with mechanical operation indicator. . Reset current = 90% 10.000
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 1 ( 3 sec )
Column B Column C Column D
Reset time = 9 Secs at TM 1.0
Column E Column F Column G
2 0.315 0.573 0.830 1.088 1.345 1.603 1.860 2.120 2.380 2.640 2.900 3.158 3.415 3.673 3.930 4.198 4.465 4.733 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
Column H Column I Column J
3 0.230 0.388 0.545 0.703 0.860 1.018 1.175 1.331 1.488 1.644 1.800 1.958 2.115 2.273 2.430 2.598 2.765 2.933 3.100 3.425 3.750 4.050 4.350 4.675 5.000 5.357 5.600 5.925 6.250 Column K Column L Column M
4 0.197 0.323 0.448 0.574 0.699 0.825 0.950 1.075 1.200 1.325 1.450 1.574 1.698 1.821 1.945 2.078 2.210 2.343 2.475 2.723 2.970 3.215 3.460 3.710 3.960 4.233 4.450 4.700 4.950 Column N Column O Column P
5 0.181 0.290 0.398 0.506 0.614 0.722 0.830 0.940 1.050 1.160 1.270 1.378 1.485 1.593 1.700 1.810 1.920 2.030 2.140 2.353 2.565 2.788 3.010 3.225 3.440 3.638 3.840 4.070 4.300 Column Q Column R Column S

Time
6 0.172 0.269 0.366 0.464 0.561 0.658 0.755 0.854 0.953 1.051 1.150 1.246 1.343 1.439 1.535 1.631 1.728 1.824 1.920 2.110 2.300 2.505 2.710 2.905 3.100 3.262 3.470 3.670 3.870 1.000 Column T Column U Column V
7 0.165 0.255 0.344 0.433 0.522 0.611 0.700 0.793 0.885 0.978 1.070 1.158 1.245 1.333 1.420 1.510 1.600 1.690 1.780 1.953 2.125 2.308 2.490 2.670 2.850 2.999 3.200 3.388 3.575 2 3 4 5 6
Column 7W 8 9 10X
Column Column Y
8 0.158 0.241 0.325 0.409 0.493 0.576 0.660 0.744 0.828 0.911 0.995 1.079 1.163 1.246 1.330 1.413 1.495 1.578 1.660 1.828 1.995 2.160 2.325 2.498 2.670 2.802 3.000 3.175 3.350 Column Z Column AA Column AB
9 0.152 0.231 0.311 0.391 0.471 0.550 0.630 0.709 0.788 0.866 0.945 1.024 1.103 1.181 1.260 1.339 1.418 1.496 1.575 1.730 1.885 2.043 2.200 2.360 2.520 2.649 2.830 2.990 3.150 Column AC Column AD Column AE
10 0.150 0.225 0.300 0.375 0.450 0.525 0.600 0.675 0.750 0.825 0.900 0.975 1.050 1.125 1.200 1.275 1.350 1.425 1.500 1.650 1.800 1.950 2.100 2.245 2.390 2.525 2.700 2.850 3.000

CDGx2 Inverse Time Curves 0.100 Plug Multiplier


1.8 Sec Starting current = 95-105%. Closing current = 95 - 105%. Reset current = 90% Column B Column C Column D
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDGColumn
2 ( 17.6
E
) Column F Column G
Reset time = 40 Secs at TM 1.0 Column H Column I Column J
2 4.30 6.00 7.70 9.40 11.10 12.80 14.50 16.25 18.00 19.75 21.50 23.25 25.00 26.75 28.50 30.25 32.00 33.75 35.50 39.5 43.50 47 50.50 54 57.50 62.25 67.00 71 75.0 100.00 Column K Column L Column M
3 2.70 3.80 4.90 6.00 7.10 8.20 9.30 10.43 11.55 12.68 13.80 14.98 16.15 17.33 18.50 19.63 20.75 21.88 23.00 25.5 28.00 30.25 32.50 35 37.50 39.5 41.50 44 46.5 Column N Column O Column P
4 1.88 2.76 3.63 4.51 5.38 6.26 7.13 8.04 8.94 9.85 10.75 11.67 12.60 13.52 14.44 15.28 16.12 16.96 17.80 19.75 21.70 23.5 25.30 27.15 29.00 30.6 32.20 34.1 36.0 Column Q Column R Column S
10.00
5 1.55 2.29 3.03 3.77 4.52 5.26 6.00 6.74 7.48 8.21 8.95 9.75 10.55 11.35 12.15 12.86 13.58 14.29 15.00 16.6 18.20 19.65 21.10 22.65 24.20 25.5 26.80 28.3 29.8 Column T Column U Column V
6 1.35 2.00 2.64 3.29 3.93 4.58 5.22 5.88 6.54 7.19 7.85 8.51 9.18 9.84 10.50 11.13 11.75 12.38 13.00 14.38 15.75 16.975 18.20 19.55 20.90 22.05 23.20 24.5 25.8 Column W Column X Column Y
1.00
7 1.20 1.78 2.35 2.93 3.50 4.08 4.65 5.24 5.83 6.41 7.00 7.59 8.18 8.76 9.35 9.93 10.50 11.08 11.65 12.83 14.00 15.1 16.20 17.425 18.65 19.675 20.70 21.8 22.9 Column Z Column AA Column AB
8 1.09 1.61 2.13 2.65 3.18 3.70 4.22 4.75 5.29 5.82 6.35 6.88 7.40 7.93 8.45 8.96 9.48 9.99 10.50 11.58 12.65 13.65 14.65 15.725 16.80 17.8 18.80 19.75 20.7 Column AC Column AD Column AE
0.10
9 1.00 1.48 1.96 2.44 2.92 3.40 3.88 4.37 4.87 5.36 5.85 6.33 6.81 7.29 7.77 8.25 8.74 9.22 9.70 10.68 11.65 12.575 13.50 14.475 15.45 16.35 17.25 18.125 19.0
2 3 4 5 6 7 8 9 10
10 0.93 1.37 1.82 2.27 2.72 3.16 3.61 4.07 4.53 4.99 5.45 5.89 6.33 6.76 7.20 7.64 8.08 8.51 8.95 9.875 10.80 11.625 12.45 13.375 14.30 15.1 15.90 16.75 17.6
Plug setting Multiplier

CDGx3 Inverse Time Curves


1.5 Sec Starting current = 103-105%. Closing current = 120% . Reset current = 90%
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 3 ( 1.5 sec )
Reset time = 50 Secs at TM 1.0
2 0.525 0.963 1.400 1.84 2.28 2.71 3.150 3.58 4.01 4.44 4.870 5.30 5.74 6.17 6.600 7.03 7.45 7.88 8.300 9.2 10.10 10.95 11.8 12.67 13.54 14.395 15.25 16.125 17
20.00 Column B Column C Column D
3 0.230 0.395 0.560 0.73 0.89 1.06 1.220 1.38 1.55 1.71 1.875 2.04 2.21 2.37 2.540 2.71 2.87 3.04 3.200 3.53 3.86 4.19 4.520 4.835 5.150 5.495 5.840 6.17 6.500
Column E Column F Column G
4 0.147 0.241 0.334 0.43 0.52 0.61 0.708 0.81 0.91 1.01 1.110 1.21 1.30 1.40 1.490 1.59 1.68 1.78 1.870 2.065 2.26 2.455 2.650 2.84 3.030 3.225 3.420 3.595 3.770 15.00
Column H Column I Column J
5 0.114 0.182 0.250 0.32 0.39 0.45 0.523 0.59 0.66 0.72 0.790 0.86 0.93 1.00 1.075 1.14 1.21 1.27 1.340 1.48 1.62 1.76 1.900 2.035 2.170 2.31 2.450 2.585 2.720
10.00 Column K Column L Column M

Time
6 0.101 0.156 0.210 0.26 0.32 0.37 0.428 0.48 0.54 0.59 0.650 0.71 0.76 0.82 0.870 0.93 0.98 1.04 1.090 1.204 1.32 1.4335 1.550 1.66 1.770 1.88 1.990 2.105 2.220
Column N Column O Column P
7 0.092 0.139 0.187 0.23 0.28 0.33 0.378 0.43 0.47 0.52 0.568 0.62 0.67 0.71 0.763 0.81 0.86 0.91 0.960 1.06 1.16 1.26 1.360 1.45 1.540 1.64 1.740 1.84 1.940 5.00
Column Q Column R Column S
8 0.086 0.129 0.172 0.22 0.26 0.30 0.345 0.39 0.43 0.47 0.518 0.56 0.61 0.65 0.696 0.74 0.78 0.83 0.870 0.959 1.05 1.136 1.225 1.3125 1.400 1.4875 1.575 1.6675 1.760 Column T Column U Column V
0.00
9 0.080 0.120 0.161 0.20 0.24 0.28 0.324 0.36 0.40 0.44 0.485 0.53 0.57 0.61 0.648 0.69 0.73 0.77 0.810 0.89 0.97 1.0525 1.135 1.2175 1.300 1.385 1.470 1.55 1.630 Column
2 3 4 5 6 7W 8 Column
9 10X Column Y
10 0.077 0.115 0.153 0.19 0.23 0.27 0.306 0.34 0.38 0.42 0.459 0.50 0.54 0.58 0.615 0.65 0.69 0.73 0.765 0.842 0.92 0.994 1.070 1.1475 1.225 1.3 1.375 1.4525 1.530 Column Z Column AA Column AB
Plug setting multiplier
Column AC Column AD Column AE
CDGx4 Inverse Time Curves
0.6 Sec Starting current = 103-105%. Closing current = 130%. Reset current = 90%
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 4 ( 0. 6 sec )
Reset time = 45 Secs at TM 1.0
2 0.295 0.738 1.180 1.623 2.065 2.508 2.950 3.388 3.825 4.263 4.700 5.150 5.600 6.050 6.500 6.975 7.450 7.925 8.400 9.400 10.400 11.100 11.800 12.800 13.800 14.750 15.700 16.450 17.200 20.000
Column B Column C Column D
3 0.128 0.276 0.425 0.574 0.723 0.871 1.020 1.178 1.335 1.493 1.650 1.801 1.953 2.104 2.255 2.429 2.603 2.776 2.950 3.175 3.400 3.775 4.150 4.500 4.850 5.200 5.550 5.825 6.100
15.000 Column E Column F Column G
4 0.088 0.164 0.240 0.316 0.392 0.468 0.544 0.624 0.704 0.785 0.865 0.952 1.039 1.125 1.212 1.297 1.381 1.466 1.550 1.685 1.820 2.010 2.200 2.375 2.550 2.745 2.940 3.070 3.200
Column H Column I Column J
5 0.071 0.116 0.162 0.208 0.254 0.299 0.345 0.398 0.450 0.503 0.555 0.599 0.643 0.686 0.730 0.794 0.858 0.921 0.985 1.083 1.180 1.290 1.400 1.510 1.620 1.730 1.840 1.940 2.040 10.000

Time
Column K Column L Column M
6 0.056 0.088 0.120 0.152 0.184 0.216 0.248 0.286 0.323 0.361 0.398 0.432 0.467 0.501 0.535 0.574 0.613 0.651 0.690 0.765 0.840 0.910 0.980 1.060 1.140 1.215 1.290 1.360 1.430 Column N Column O Column P
5.000
7 0.046 0.070 0.095 0.120 0.145 0.169 0.194 0.221 0.249 0.276 0.303 0.329 0.354 0.380 0.405 0.434 0.463 0.491 0.520 0.578 0.635 0.688 0.740 0.810 0.880 0.925 0.970 1.025 1.080 Column Q Column R Column S
8 0.037 0.058 0.078 0.099 0.119 0.140 0.160 0.181 0.203 0.224 0.245 0.266 0.287 0.307 0.328 0.351 0.374 0.397 0.420 0.463 0.505 0.548 0.590 0.638 0.685 0.723 0.760 0.808 0.855 0.000 Column T Column U Column V
9 0.034 0.051 0.068 0.085 0.102 0.119 0.136 0.154 0.171 0.189 0.206 0.224 0.242 0.259 0.277 0.295 0.314 0.332 0.350 0.384 0.417 0.454 0.490 0.528 0.565 0.598 0.630 0.668 0.705 2 3 4 5 6Column7 W 8 9
Column10
X Column Y
10 0.030 0.045 0.060 0.075 0.090 0.105 0.120 0.135 0.150 0.165 0.180 0.195 0.210 0.225 0.240 0.255 0.270 0.285 0.300 0.330 0.360 0.390 0.420 0.450 0.480 0.512 0.544 0.572 0.600 Column Z
Plug setting multiplier Column AA Column AB
Column AC Column AD Column AE
Doble Test Plans
CDGx1 Inverse Time Curves
1.3 Sec CDG 1 ( 1.3 sec )
Starting current = 103-105%. Closing current = 115% or 117% if fitted with mechanical operation indicator Column B Column C Column D Column E
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 10.000
Column F Column G Column H Column I
Reset time = 4 Secs at TM 1.0
Column J Column K Column L Column M
2 0.101 0.181 0.262 0.343 0.424 0.504 0.585 0.674 0.763 0.851 0.940 1.035 1.130 1.225 1.320 1.415 1.510 1.605 1.700 1.910 2.120 2.325 2.530 2.740 2.950 3.175 3.400 3.625 3.850 1.000
Column N Column O Column P Column Q
4 0.082 0.127 0.173 0.218 0.263 0.308 0.354 0.403 0.452 0.501 0.550 0.601 0.651 0.702 0.752 0.802 0.851 0.901 0.950 1.055 1.160 1.268 1.375 1.483 1.590 1.700 1.810 1.915 2.020

e
Column R Column S Column T Column U

Tim
6 0.075 0.114 0.153 0.192 0.231 0.270 0.309 0.348 0.387 0.426 0.465 0.505 0.546 0.586 0.626 0.665 0.703 0.742 0.780 0.865 0.950 1.035 1.120 1.203 1.285 1.368 1.450 1.535 1.620 0.100 Column V Column W Column X Column Y
8 0.069 0.104 0.139 0.174 0.209 0.244 0.279 0.314 0.349 0.384 0.419 0.455 0.491 0.526 0.562 0.597 0.631 0.666 0.700 0.772 0.844 0.917 0.990 1.063 1.135 1.205 1.275 1.350 1.425 2 3 4 5 6 7 8 9 10 Column Z Column AA Column AB Column AC
0.010 Column AD Column AE
Page 5
Plug setting multiplier
CDG Curves

CDG 1 ( 1.3 sec )


Column B Column C Column D Column E
10.000
Column F Column G Column H Column I
Column J Column K Column L Column M
1.000
Column N Column O Column P Column Q

e
Column R Column S Column T Column U

Tim
0.100 Column V Column W Column X Column Y
2 3 4 5 6 7 8 9 10
Column Z Column AA Column AB Column AC
10 0.065 0.098 0.130 0.163 0.195 0.228 0.260 0.293 0.325 0.358 0.390 0.423 0.455 0.488 0.520 0.552 0.584 0.616 0.648 0.714 0.779 0.845 0.910 0.975 1.040 1.105 1.170 1.235 1.300 0.010 Column AD Column AE
Plug setting multiplier
CDGx1 Inverse Time Curves
2.7 Sec Starting Current = 95-105%. Closing current = 100% .Reset time = 4 - 9 Secs at TM 1.0 10.000 CDG 1 ( 2.7 sec )
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000
Reset time = 9 Secs at TM 1.0
2 0.390 0.59 0.790 0.990 1.190 1.390 1.590 1.800 2.010 2.220 2.430 2.643 2.855 3.068 3.280 3.490 3.700 3.910 4.120 4.535 4.950 5.345 5.740 6.120 6.500 6.940 7.380 7.790 8.200 Column B Column C Column D Column E
4 0.232 0.34 0.450 0.559 0.668 0.777 0.886 1.002 1.118 1.234 1.350 1.458 1.565 1.673 1.780 1.895 2.010 2.125 2.240 2.455 2.670 2.875 3.080 3.298 3.515 3.753 3.990 4.165 4.340 1.000
Column F Column G Column H Column I

Time
6 0.185 0.27 0.355 0.440 0.525 0.609 0.694 0.787 0.880 0.972 1.065 1.149 1.233 1.316 1.400 1.490 1.580 1.670 1.760 1.935 2.110 2.265 2.420 2.600 2.780 2.965 3.150 3.305 3.460 Column J Column K Column L Column M
8 0.154 0.23 0.304 0.379 0.454 0.530 0.605 0.681 0.757 0.834 0.910 0.985 1.060 1.135 1.210 1.288 1.365 1.443 1.520 1.670 1.820 1.960 2.100 2.245 2.390 2.555 2.720 2.860 3.000 Column N Column O Column P Column Q
Column R Column S Column T Column U
10 0.134 0.20 0.270 0.338 0.407 0.475 0.543 0.610 0.677 0.743 0.810 0.876 0.943 1.009 1.075 1.146 1.218 1.289 1.360 1.494 1.627 1.759 1.890 2.025 2.160 2.295 2.430 2.565 2.700
Column V Column W Column X Column Y
0.100 Column Z Column AA Column AB Column AC
CDGx1 Inverse Time Curves 2 3 Plug
4 setting
5 multiplier
6 7 8 9 10 Column AD Column AE
3.0 Sec Starting Current = 103-105%. Closing current = 115% or 117% if fitted with mechanical operation indicator. Reset Time = 4 - 9 Secs at TM 1.0 10.000
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 1 ( 3 sec )
Column B Column C Column D Column E
Reset time = 9 Secs at TM 1.0
Column F Column G Column H Column I
2 0.315 0.573 0.830 1.088 1.345 1.603 1.860 2.120 2.380 2.640 2.900 3.158 3.415 3.673 3.930 4.198 4.465 4.733 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
Column J Column K Column L Column M
4 0.197 0.323 0.448 0.574 0.699 0.825 0.950 1.075 1.200 1.325 1.450 1.574 1.698 1.821 1.945 2.078 2.210 2.343 2.475 2.723 2.970 3.215 3.460 3.710 3.960 4.233 4.450 4.700 4.950
Column N Column O Column P Column Q
6 0.172 0.269 0.366 0.464 0.561 0.658 0.755 0.854 0.953 1.051 1.150 1.246 1.343 1.439 1.535 1.631 1.728 1.824 1.920 2.110 2.300 2.505 2.710 2.905 3.100 3.262 3.470 3.670 3.870 1.000

Time
Column R Column S Column T Column U
8 0.158 0.241 0.325 0.409 0.493 0.576 0.660 0.744 0.828 0.911 0.995 1.079 1.163 1.246 1.330 1.413 1.495 1.578 1.660 1.828 1.995 2.160 2.325 2.498 2.670 2.802 3.000 3.175 3.350 2 3 4 5 6 7 8 9 10
Column V Column W Column X Column Y
10 0.150 0.225 0.300 0.375 0.450 0.525 0.600 0.675 0.750 0.825 0.900 0.975 1.050 1.125 1.200 1.275 1.350 1.425 1.500 1.650 1.800 1.950 2.100 2.245 2.390 2.525 2.700 2.850 3.000 Column Z Column AA Column AB Column AC
Column AD Column AE
CDGx2 Inverse Time Curves 0.100 Plug Multiplier
Sec Starting current = 95-105%. Closing current = 100% Column B Column C Column D Column E
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 2 ( 17.6 )
Column F Column G Column H Column I
Reset time = 40 Secs at TM 1.0 Column J Column K Column L Column M
2 4.30 6.00 7.70 9.40 11.10 12.80 14.50 16.25 18.00 19.75 21.50 23.25 25.00 26.75 28.50 30.25 32.00 33.75 35.50 39.5 43.50 47 50.50 54 57.50 62.25 67.00 71 75.0 100.00 Column N Column O Column P Column Q
4 1.88 2.76 3.63 4.51 5.38 6.26 7.13 8.04 8.94 9.85 10.75 11.67 12.60 13.52 14.44 15.28 16.12 16.96 17.80 19.75 21.70 23.5 25.30 27.15 29.00 30.6 32.20 34.1 36.0 10.00 Column R Column S Column T Column U
6 1.35 2.00 2.64 3.29 3.93 4.58 5.22 5.88 6.54 7.19 7.85 8.51 9.18 9.84 10.50 11.13 11.75 12.38 13.00 14.38 15.75 16.975 18.20 19.55 20.90 22.05 23.20 24.5 25.8 1.00 Column V Column W Column X Column Y
8 1.09 1.61 2.13 2.65 3.18 3.70 4.22 4.75 5.29 5.82 6.35 6.88 7.40 7.93 8.45 8.96 9.48 9.99 10.50 11.58 12.65 13.65 14.65 15.725 16.80 17.8 18.80 19.75 20.7 0.10 Column Z Column AA Column AB Column AC
10 0.93 1.37 1.82 2.27 2.72 3.16 3.61 4.07 4.53 4.99 5.45 5.89 6.33 6.76 7.20 7.64 8.08 8.51 8.95 9.875 10.80 11.625 12.45 13.375 14.30 15.1 15.90 16.75 17.6 2 3 4 5 6 7 8 9 10 Column AD Column AE
Plug setting Multiplier
CDGx3 Inverse Time Curves
1.5 Sec Starting current = 103-105%. Closing current = 120%
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 3 ( 1.5 sec )
Reset time = 50 Secs at TM 1.0 Column B Column C Column D Column E
2 0.525 0.963 1.400 1.84 2.28 2.71 3.150 3.58 4.01 4.44 4.870 5.30 5.74 6.17 6.600 7.03 7.45 7.88 8.300 9.2 10.10 10.95 11.8 12.67 13.54 14.395 15.25 16.125 17 20.00 Column F Column G Column H Column I
4 0.147 0.241 0.334 0.43 0.52 0.61 0.708 0.81 0.91 1.01 1.110 1.21 1.30 1.40 1.490 1.59 1.68 1.78 1.870 2.065 2.26 2.455 2.650 2.84 3.030 3.225 3.420 3.595 3.770 15.00 Column J Column K Column L Column M
10.00
6 0.101 0.156 0.210 0.26 0.32 0.37 0.428 0.48 0.54 0.59 0.650 0.71 0.76 0.82 0.870 0.93 0.98 1.04 1.090 1.204 1.32 1.4335 1.550 1.66 1.770 1.88 1.990 2.105 2.220 Column N Column O Column P Column Q

Time
5.00
8 0.086 0.129 0.172 0.22 0.26 0.30 0.345 0.39 0.43 0.47 0.518 0.56 0.61 0.65 0.696 0.74 0.78 0.83 0.870 0.959 1.05 1.136 1.225 1.3125 1.400 1.4875 1.575 1.6675 1.760 0.00 Column R Column S Column T Column U
10 0.077 0.115 0.153 0.19 0.23 0.27 0.306 0.34 0.38 0.42 0.459 0.50 0.54 0.58 0.615 0.65 0.69 0.73 0.765 0.842 0.92 0.994 1.070 1.1475 1.225 1.3 1.375 1.4525 1.530 2 3 4 5 6 7 8 9 10 Column V Column W Column X Column Y
Plug setting multiplier Column Z Column AA Column AB Column AC
Column AD Column AE
CDGx4 Inverse Time Curves
0.6 Sec Starting current = 103-105%. Closing current = 130%
Plug Set Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 CDG 4 ( 0. 6 sec )
Reset time = 45 Secs at TM 1.0 Column B Column C Column D Column E Column F
2 0.295 0.738 1.180 1.623 2.065 2.508 2.950 3.388 3.825 4.263 4.700 5.150 5.600 6.050 6.500 6.975 7.450 7.925 8.400 9.400 10.400 11.100 11.800 12.800 13.800 14.750 15.700 16.450 17.200 20.000 Column G Column H Column I Column J Column K
15.000
4 0.088 0.164 0.240 0.316 0.392 0.468 0.544 0.624 0.704 0.785 0.865 0.952 1.039 1.125 1.212 1.297 1.381 1.466 1.550 1.685 1.820 2.010 2.200 2.375 2.550 2.745 2.940 3.070 3.200 10.000 Column L Column M Column N Column O Column P

e
5.000

Tim
6 0.056 0.088 0.120 0.152 0.184 0.216 0.248 0.286 0.323 0.361 0.398 0.432 0.467 0.501 0.535 0.574 0.613 0.651 0.690 0.765 0.840 0.910 0.980 1.060 1.140 1.215 1.290 1.360 1.430 0.000
Column Q Column R Column S Column T Column U
8 0.037 0.058 0.078 0.099 0.119 0.140 0.160 0.181 0.203 0.224 0.245 0.266 0.287 0.307 0.328 0.351 0.374 0.397 0.420 0.463 0.505 0.548 0.590 0.638 0.685 0.723 0.760 0.808 0.855 Column V Column W Column X Column Y Column Z
2 3 4 5 6 7 8 9 10
10 0.030 0.045 0.060 0.075 0.090 0.105 0.120 0.135 0.150 0.165 0.180 0.195 0.210 0.225 0.240 0.255 0.270 0.285 0.300 0.330 0.360 0.390 0.420 0.450 0.480 0.512 0.544 0.572 0.600 Column AA Column AB Column AC Column AD Column AE
Plug setting multiplier

Page 6
PBO Curves

PBO 2 Second Relay Curves

Time Mult 0.050 0.075 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325
Plug Set
1.5 1.095 1.488 1.880 2.273 2.665 3.058 3.45 3.881 4.313 4.744 5.175 5.606
2 0.515 0.763 1.010 1.258 1.505 1.753 2.000 2.238 2.475 2.713 2.950 3.188
2.5 0.390 0.575 0.760 0.945 1.130 1.315 1.500 1.688 1.875 2.063 2.250 2.438
3 0.310 0.465 0.620 0.775 0.930 1.085 1.240 1.391 1.543 1.694 1.845 1.996
4 0.233 0.364 0.495 0.626 0.758 0.889 1.020 1.136 1.253 1.369 1.485 1.601
5 0.218 0.329 0.440 0.551 0.663 0.774 0.885 0.987 1.089 1.191 1.293 1.394
6 0.198 0.296 0.395 0.494 0.593 0.691 0.790 0.884 0.978 1.071 1.165 1.259
7 0.185 0.276 0.368 0.460 0.552 0.643 0.735 0.821 0.906 0.992 1.078 1.163
8 0.178 0.261 0.345 0.429 0.513 0.596 0.680 0.761 0.843 0.924 1.005 1.086
9 0.170 0.248 0.325 0.403 0.480 0.558 0.635 0.711 0.786 0.862 0.938 1.013
10 0.165 0.238 0.310 0.383 0.455 0.528 0.600 0.673 0.746 0.819 0.893 0.966

Page 7
PBO Curves

0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900

6.038 6.469 6.900 7.350 7.800 8.250 8.700 9.600 10.500 11.550 12.600 13.650 14.7 15.525 16.350
3.425 3.663 3.900 4.138 4.375 4.613 4.850 5.325 5.800 6.375 6.950 7.525 8.100 8.575 9.050
2.625 2.813 3.000 3.188 3.375 3.563 3.750 4.125 4.500 4.875 5.250 5.625 6.000 6.375 6.750
2.148 2.299 2.450 2.606 2.763 2.919 3.075 3.388 3.700 4.013 4.325 4.638 4.950 5.250 5.550
1.718 1.834 1.950 2.084 2.218 2.351 2.485 2.753 3.020 3.265 3.510 3.755 4.000 4.230 4.460
1.496 1.598 1.700 1.806 1.913 2.019 2.125 2.338 2.550 2.778 3.005 3.233 3.460 3.670 3.880
1.353 1.446 1.540 1.633 1.725 1.818 1.910 2.095 2.280 2.485 2.690 2.895 3.100 3.275 3.450
1.249 1.334 1.420 1.508 1.595 1.683 1.770 1.945 2.120 2.303 2.485 2.668 2.850 3.023 3.195
1.168 1.249 1.330 1.413 1.495 1.578 1.660 1.825 1.990 2.155 2.320 2.485 2.650 2.820 2.990
1.089 1.164 1.240 1.318 1.395 1.473 1.550 1.705 1.860 2.010 2.160 2.310 2.460 2.630 2.800
1.039 1.112 1.185 1.258 1.331 1.404 1.478 1.624 1.770 1.915 2.060 2.205 2.350 2.513 2.675

Page 8
PBO Curves

0.950 1.000
Column B Column C Column D
PBO 2 second relay
Column E Column F Column G
17.175 18.000
Column H Column I Column J
9.525 10.000 20.000
Column K Column L Column M
7.125 7.500 18.000
16.000 Column N Column O Column P
5.850 6.150 14.000 Column Q Column R Column S
4.690 4.920 Time (secs) 12.000 Column T Column U Column V
10.000
4.090 4.300 Column W Column X Column Y
8.000
3.625 3.800 6.000 Column Z Column AA Column AB
3.368 3.540 4.000 Column AC Column AD Column AE
2.000
3.160 3.330 0.000
2.970 3.140 1.5 2 2.5 3 4 5 6 7 8 9 10
2.838 3.000 Plug setting multiplier

Page 9
PBO Curves

mn C Column D
mn F Column G
mn I Column J
mn L Column M
mn O Column P
mn R Column S
mn U Column V
mn X Column Y
mn AA Column AB
mn AD Column AE

10

Page 10
Asea curves

RI 2 - 10 sec Curve

Time Mult 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00
Multiplier
1.3 1.150 1.488 1.825 2.163 2.500 2.838 3.175 3.513 3.850 4.188 4.525 4.863 5.200 5.538 5.875
1.7 0.875 1.136 1.397 1.658 1.919 2.180 2.441 2.702 2.963 3.223 3.484 3.745 4.006 4.267 4.528
2 0.7500 0.9883 1.2266 1.4648 1.7031 1.9414 2.1797 2.4180 2.6563 2.8945 3.1328 3.3711 3.6094 3.8477 4.0859
2.5 0.7000 0.9141 1.1281 1.3422 1.5563 1.7703 1.9844 2.1984 2.4125 2.6266 2.8406 3.0547 3.2688 3.4828 3.6969
3 0.5893 0.7946 1.0000 1.2054 1.4107 1.6161 1.8214 2.0268 2.2321 2.4375 2.6429 2.8482 3.0536 3.2589 3.4643
6 0.5000 0.6844 0.8688 1.0531 1.2375 1.4219 1.6063 1.7906 1.9750 2.1594 2.3438 2.5281 2.7125 2.8969 3.0813
10 0.4500 0.6250 0.8000 0.9750 1.1500 1.3250 1.5000 1.6750 1.8500 2.0250 2.2000 2.3750 2.5500 2.7250 2.9000
20 0.4000 0.5688 0.7375 0.9063 1.0750 1.2438 1.4125 1.5813 1.7500 1.9188 2.0875 2.2563 2.4250 2.5938 2.7625

Page 11
Asea curves

9.50 10.00

6.213 6.550
4.789 5.050
4.3242 4.5625
3.9109 4.1250
3.6696 3.8750
3.2656 3.4500
3.0750 3.2500
2.9313 3.1000

Page 12
Diff Bias

Manufacturer ReIay Rating Calculated Doble Test Currents Sources


Reyrolle 2C21/BC In Amp 5 Bias Curve I1 I2 set for 180 degrees
I1 Operate 10% 15% 20% 30% 40% 10% 15% 20% 30% 40%
1 0 0 0 0 0 1 0 0 0 0 0
2.5 1.52 1.77 2.04 2.5 4.02 4.27 4.54
5 2.03 2.54 3.08 5 7.03 7.54 8.08
10 2.06 3.09 4.15 10 12.06 13.09 14.15
15 3.10 4.63 6.23 15 18.10 19.63 21.23
20 4.13 6.17 8.30 20 24.13 26.17 28.30
23.75 4.90 7.33 9.86 23.75 28.65 31.08 33.61

I diff> Operate Time xI.5 pu 48 mSec. Balance Test Tx Imped% Tx Prim Voltage
pu= 1 Amps x5.0 pu 45 mSec. Test V 430 9.49 ###
I diff>> Operate Time xI.5 pu 18 mSec. Test I 35.7 Tx Prim I Tx Sec Voltage
pu= Amps x5.0 pu 10 mSec. 260 11400

Manufacturer ReIay Rating Calculated Doble Test Currents Sources


Reyrolle 4C21/BC In Amp 1 Bias Curve I1 I2 set for 180 degrees
I1 Operate 10% 15% 20% 30% 40% 10% 15% 20% 30% 40%
0.2 0 0 0 0 0 0.2 0 0 0 0 0
0.5 0.30 0.35 0.41 0.5 0.80 0.85 0.91
1 0.41 0.51 0.62 1 1.41 1.51 1.62
2 0.41 0.62 0.83 2 2.41 2.62 2.83
3 0.62 0.93 1.25 3 3.62 3.93 4.25
4 0.83 1.23 1.66 4 4.83 5.23 5.66
5 1.03 1.54 2.08 5 6.03 6.54 7.08

I diff> Operate Time xI.5pu 48 mSec.


pu= 0.2 x5.0 pu 45 mSec.
I diff>> Operate Time xI.5pu 18 mSec.
pu= x5.0 pu 10 mSec.

Manufacturer ReIay Rating Calculated Doble Test Currents Sources


GEC DMH In Amp 1 Bias Curve I1 I2 set for 180 degrees
I1 Operate 10% 15% 20% 30% 50% 10% 15% 20% 30% 50%
0.1 0 0 0 0 0 0.1 0 0 0 0 0
0.5 0.5
1 1
2 2
3 3
4 4
5 5
Inst 8
I diff> Operate Time xI.5pu 40 mSec.
pu= 0.1 x5.0 pu 35 mSec.
I diff>> Operate Time xI.0pu 10 mSec.
pu= 8 I inst setting= 8

prefered
0.36 0.64 10 10 0.69 0.4 2
0.80 1.20 10 10 0.76 1.25 0.8 4
1.15 1.85 10 10 1.11 1.90 1.2 6

Page 13
Diff Bias

1.48 2.53 10 10 1.44 2.57 1.8 9


1.80 3.20 10 10 1.75 3.25 2.4 12
2.11 3.89 10 10 2.08 3.93 2.6 13
2.43 4.57 10 10 2.39 4.61 3 15
2.74 5.26 10 10 2.70 5.30 3.4 17

Page 14
Diff Bias

40

35

30

25

20

15

10

0
1 2.5 5 10 15 20 23.75

Page 15

You might also like