You are on page 1of 24

Environmental Stress Chamber

AR series

CAT.NO.E16141
Rapid Temperature Changes of 18K/min.
Environmental stress chambers that carve a path into the future of environmental testing.
The pursuit of reliability requires speed in providing results within limited periods of
time and the accurate reproduction of environments.
This chamber series support heat load from specimens, and provide superior levels of
temperature change performance and wide temperature & humidity control range.
The lineup consists of twenty chambers that can be selected in accordance
with temperature & humidity range, inside capacity and temperature change rate.
Temperature change rate is between 4K/minute and 18K/minute, which conforms to
IEC standards and test standards for automotive parts.
The processing speed of the new instrumentation has been greatly improved,
and connecting the chambers to an Ethernet enables the operation status to be monitored
and managed remotely from your desk.
Contains all areas of performance demanded by constant temperature & humidity chambers.

Contents
● Rapid-Rate Temperature Cycle Type P.3-10
● Standard Type P.11-19
● Network P.20
● Other products P.21-22

ARSF−0250−15
ARSF−0400−15
ARSF−0800−15
1
Model Lineup Boasting Superior Temperature Change Performance
Rapid-Rate Temperature Cycle Type
Standard Type

20

ARSF/ARGF-0250-15
TCC-150W
Rapid-Rate Thermal
Cycle Chamber

15 ARSF/ARGF-0400-15 ARSF/ARGF-0800-15
Temperature pull-down rate (℃ / min.)

10 ARSF/ARGF-0400-10 ARSF/ARGF-0800-10
ARSF/ARGF
-0250-10

ARL/ARU
-0680 ARL/ARU
5 ARS/ARG-0220 -1100
SH/SU-242-5
Bench-Top Type
Temperature(& Humidity) ARS/ARG ARS/ARG
ARS/ARG
Chamber -0680 -1100
-0390

250 500 750 1000


Test area capacity (L)

ARS−0390 ARS−1100 ARL−0680


ARS−0220

*Viewing window is optional. 2


Rapid-Rate Temperature

Features
Cycle Type

ARSF・ARGF

Rapid-Rate Temperature Cycle Type

Temperature & Humidity Range


Standard Type

Minimum temp.: -70°C


Maximum temp.: +180°C
Humid. (ARSF only): 10 to 98%rh

Temperature Change Rate


Three variations: 10K/min., 15K/min.
and 18K/min. between -45°C ⇔ +155°C.
Perfect for tests in conformance with
IEC and other official standards, as well
as automotive part standards.

Totally Frost-Free (ARSF)


Frosting will not appear on any part of
Temperature Change Rate the unit despite the temperature &
humidity control range of range from
Capacity 249L 398L 784L
10 to 98%rh. Eradicating the need to
Temp. range −45⇔+155℃ remove frosting provides stable and
Heat up 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min. continuous operations.
Pull down 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min.
* ARSF: temperature & humidity, ARGF: temperature only
Heat Load up to 9000W
Allowable heat load is different depends
Temperature & Humidity Control Range
(In environment of ambient temperature of +23℃, no specimen.) on models and operation conditions.
(Page 6 to 7)
ARSF
100 * For your safety, please be sure to connect the
98
90 power through specimen power supply
80 control terminal.
70 *Temperature-triggered circuit breaker is
Relative 60 available (customized option).
Humidity 50
(%rh)
40
30
High-Accuracy Temperature &
20 Humidity Control
10 Temperature and humidity is stable as
0 well as during constant operation as
10 20 30 40 50 60 70 80 90 100
15 65 95 during gradient operation. This
Temperature (℃)
provides peace of mind during
* Totally frost free, no limitation of continuous operation. temperature & humidity cycle testing.

Energy-Saving with Dual PID Control


Dual PID Control (Proportional-Integral-
Differential: control that enables the
Temperature & Humidity Control Range segmentation of refrigeration capacity)
(In environment of ambient temperature of +20℃, no specimen.)
mostly controls only the refrigerator at
100 98 0°C or lower, thereby saving energy.
90
80
Relative 70 ARS・ARL
Humidity 60
3 (%rh) 50
40
30
Rapid-Rate Temperature
Features

Cycle Type
ARSF・ARGF

Specimen Temperature Control


(Option)
Attaching a temperature measurement

Standard Type
sensor to the specimen enables the
temperature of the specimen to be
monitored and controlled, which makes
tests even more accurate.

Easy Access to Specimens


Equipped with ø50mm cable ports on
both right & left sides as standard.
100mm, 150mm or ports with other
diameters can also be added or
modified on an optional basis, and it is
also possible to arrange for door notches
in order to enable specimen cables or
other apparatus to be installed within Inside of the ARSF-0800 chamber
the chamber.

Viewing Windows as Standard


Equipped with viewing windows as
standard, and chamber lamp (LED
lamps) provide greater visibility.

Size of Viewing Window


ARSF/ARGF-0250/0400: W180×H260mm
ARSF/ARGF-0800: W295×H380mm Chamber
lamp switch
Viewing window

Drawer-type Water Tank


A large-capacity water tank is located
on the front of the chamber.
Water can also be supplied directly from
a water purifier on an optional basis.

Door Locks
Locks have been fitted on the doors for
convenience in order to prevent the door
from opening during testing and to Water tank Key
ensure careful management of
specimens and tests. ● Test Standard Conformance
・IEC 60068-2-1: Cold
Global Safety Standards ・IEC 60068-2-2: Dry heat
・IEC 60068-2-14: Change of temperature with specified rate of change
ISO12100 (Safety of machinery)
・IEC 60068-2-30: Damp heat,cyclic
ISO14121 (Risk assessment)
・IEC 60068-2-38: Composit temperature/humidity cyclic test
IEC61000-6-2, IEC61000-6-4 (EMC)
・IEC 60068-2-78: Damp heat,steady state
EN50581 (RoHS)
・IEC 61747 (5.2.7): Liquid crystal and solid-state display devices
CE marking (For marked models & Environmental,endurance and mechanical test
power voltage, see page 6 to 7.) ・ISO 16750-4 (5.3): Road vehicles (Temperature cycling)
4
Rapid-Rate Temperature

Email alert
Controller
Cycle Type

PC ARSF・ARGF
PC
Ethernet Intranet

N instrumentation P-300 (company LAN) 携帯電話


スマートフォン
Mail server
AR series Mobile phone Color LCD Touch Panel
Environmental
Stress Chamber
Standard Type

A 6.5-inch wide color LCD fitted with


タブレットコントローラー
(オプション)
LED backlight. Tabs are displayed at
the bottom of the screen to facilitate
access to other screens.
Program Copy and Computer Editing
Multilingual Support
Copy
The language used by the instrumentation
can be changed with the screen settings
(Japanese / English / Chinese
(simplified / traditional) / Korean).
Edit

Information Function
The INFO icon will blink when chamber
小型環境試験器
(Wi-Fi 機能搭載)
information requiring attention.
・ Inspection Period Notifications
It is possible to randomly preset the
period and details of inspections for
humidifier plates and condenser
Network filters. 無線 LAN による接続例
・ Inspection Notifications Wi-Fi ルーター
Wi-Fi router When the monitoring value goes over (オプション)
the threshold, this notifications
encourage inspection.
Information Monitor objects:
Ethernet
PC compressor amperage & condenser Ethernet
cooling-water temperature. スマートフ
小型環境試験器
Smartphone Tablet controller
AR series 内蔵ワイヤレスダイレクトによ
Registering Test Patterns
ワイヤレスダイレクト
(オプション)
Program operation: 40 patterns (99 steps
per program)
Constant operation: 3 patterns

USB flash drive port Test Data Records


小型環境試験器
Temperature & humidity settings and
Program Copy and Computer Editing measurement values can be recorded on
the internal memory and external
memories.

Copy
Program Pattern
スマートフォンCopying
It is possible to copy program patterns
between chambers with the use of USB
flash drives without the need for PC
Standard Type Rapid-Rate operations.
Temperature Cycle Type
(USB flash drives not supplied.)
Edit

* Some items may not be copied between different models and chambers with
5 different options.
Rapid-Rate Temperature
ARSF −70〜+180℃・10〜98%rh

Cycle Type
TEMPERATURE & HUMIDITY CHAMBER

Model ARSF-0250-10 ARSF-0250-15 ARSF-0400-10 ARSF-0400-15 ARSF-0800-10 ARSF-0800-15


System Balanced Temperature & Humidity Control (BTHC) system
Temperature range −70 to +180℃
Temperature fluctuation ±0.3K

Standard Type
Temperature variation in space −70 to +150℃: 1.5K, +150.1 to +180℃: 2.0K
Temp. performance *1

Temp. rate Heat up rate 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min.
of change Pull down rate 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min.
+20℃ to +180℃
Temperature Heat up time
extremes 20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
achievement +20℃ to −70℃
time Pull down time
20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
Allowable heat load *2 6000W 9000W
Temp. & humid. range +10 to 95℃/ 10 to 98%rh
Temp. & humid.
performance *1

Humid. fluctuation ±2.5%rh


550W (Test area conditions:
Max. allowable heat load 350W (Test area conditions: +25 to 95℃/ 90%rh)
+25 to 95℃/ 90%rh)
Exterior material Stainless steel plate: 18 Cr stainless steel plate, hairline finish
Test area material Stainless steel plate: 18−8 Cr−Ni stainless steel plate, 2B polish
Heater Nichrome strip wire heater
Humidifier Sheathed heater
Cooler / Dehumidifier Plate fin cooler
Water tank capacity 16L 32L
System Mechanical cascade refrigeration
Scroll-type
Refrigerator

Compressor
4.47kW×4.47kW 5.59kW×5.59kW 4.47kW×4.47kW 5.59kW×5.59kW 9.69kW×9.69kW
Condenser Water-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A/R508A
Capacity 249L 398L 784L
Chamber total load capacity 100kg (shelf support pole: 90kg, floor: 70kg)
Inside dimensions mm *3 600×830×500 600×830×800 1000×980×800
Outside dimensions mm *3 800×1703×1900 800×1703×2200 1200×1853×2200
Weight 725kg 730kg 750kg 755kg 910kg 1000kg
Drain hose, 50mm cable port (x2, one on the right & left sides), chamber lamp,
casters ×4 (with leveling feet), time signal terminal ×2, specimen power supply control terminal,
Equipment
Ethernet port (LAN port), USB memory port,
viewing window (effective view 0250,0480: W180×H260(mm) 0800: W295×H380(mm))
Shelf (18Cr-8Ni stainless steel), shelf brackets (18Cr-8Ni stainless steel), key (×2 For door),
Accessories cable port rubber plug (φ50mm ×2), breaker handle stopper , wet bulb wick,
cartridge fuse (7A ×3, 3A ×1), Operation manual *Power cable is not included.
Ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz 60A 78A 60A 78A 86A 126A


Power 220V AC 3φ60Hz *4 58A 76A 58A 76A 83A 122A
supply
(selectable) 380V AC 3φ50Hz *4 27A 34A 27A 34A 36A 53A
400V AC 3φ50Hz *4 27A 34A 27A 34A 36A 52A
Cooling water flow rate
3300L/h 4740L/h 3300L/h 4740L/h 6360L/h
(Reference water temp.+32°C)
Noise level *5 65dB
*1: The performance values are based on IEC60068-3-5:2001 and *3: Dimensions do not include protrusions.
IEC60068-3-6:2001; Performance figures are given for a +23°C, *4: Conforms to CE marking based on EU directives.
ambient temperature relative humidity of 65±20%rh, rated voltage, *5: Measured in anechoic room. Measurement points set 1m apart from
and no specimen inside the test area. the front of the chamber, and 1.2m above the floor (in compliance with
*2: Test area temperature: +20°C JIS-Z-8731:1999 A-weigted sound pressure level).
6
Rapid-Rate Temperature

ARGF −70〜+180℃
Cycle Type

TEMPERATURE CHAMBER

Model ARGF-0250-10 ARGF-0250-15 ARGF-0400-10 ARGF-0400-15 ARGF-0800-10 ARGF-0800-15


System Balanced Temperature Control system (BTC) system
Temperature range −70 to +180℃
Temperature fluctuation ±0.3K
Temperature Performance *1
Standard Type

Temperature variation in space −70 to +150℃: 1.5K, +150.1 to +180℃: 2.0K

Temp. rate Heat up rate 10K/ min. 18K/ min. 10K/ min. 15K/ min. 10K/ min. 15K/ min.
of change Pull down rate 10K/ min. 18K/ min. 10K/ min. 15K/ min. 10K/ min. 15K/ min.
+20℃ to +180℃
Temperature Heat up time
extremes 20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
achievement +20℃ to −70℃
time Pull down time
20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
Allowable heat load *2 6000W 9000W
Exterior material Stainless steel plate: 18 Cr stainless steel plate, hairline finish
Test area material Stainless steel plate: 18−8 Cr−Ni stainless steel plate, 2B polish
Heater Nichrome strip wire heater
Cooler Plate fin cooler
System Mechanical cascade refrigeration
Scroll-type
Refrigerator

Compressor
4.47kW×4.47kW 5.59kW×5.59kW 4.47kW×4.47kW 5.59kW×5.59kW 9.69kW×9.69kW
Condenser Water-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A/R508A
Capacity 249L 398L 784L
Chamber total load capacity 100kg (shelf support pole: 90kg, floor: 70kg)
Inside dimensions mm *3 600×830×500 600×830×800 1000×980×800
Outside dimensions mm *3 800×1703×1900 800×1703×2200 1200×1853×2200
Weight 715kg 720kg 740kg 745kg 900kg 990kg
Drain hose, cable port (I.D. φ50 mm on the left/right side), chamber lamp,
casters ×4 (with leveling feet), time signal terminal ×2, specimen power supply control terminal,
Equipment
Ethernet port (LAN port), USB memory port,
viewing window (effective view 0250,0480: W180×H260(mm) 0800: W295×H380(mm))
Shelf (18Cr-8Ni stainless steel), shelf brackets (18Cr-8Ni stainless steel), key (×2 For door),
Accessories cable port rubber plug (φ50mm ×2), breaker handle stopper , wet bulb wick,
cartridge fuse (7A ×3, 3A ×1), Operation manual *Power cable is not included.
Ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz 60A 78A 60A 78A 86A 126A


Power 220V AC 3φ60Hz *4 58A 76A 58A 76A 83A 122A
supply
(selectable) 380V AC 3φ50Hz *4 27A 34A 27A 34A 36A 53A
400V AC 3φ50Hz *4 27A 34A 27A 34A 36A 52A
Cooling water flow rate
3300L/h 4740L/h 3300L/h 4740L/h 6360L/h
(Reference water temp.+32°C)
Noise level *5 65dB
*1: The performance values are based on IEC60068-3-5:2001 and IEC60068-3-6:2001; Performance figures are given for a +23°C,
ambient temperature relative humidity of 65±20%rh, rated voltage, and no specimen inside the test area.
*2: Test area temperature: +20°C
*3: Dimensions do not include protrusions.
*4: Conforms to CE marking based on EU directives.
*5: Measured in anechoic room. Measurement points set 1m apart from the front of the chamber, and 1.2m above the floor
(in compliance with JIS-Z-8731:1999 A-weigted sound pressure level).

7
Rapid-Rate Temperature
Options

Cycle Type
Power cable Water tank Specimen basket

・ 2.5 m For supplying water to the chamber’s For small specimens that cannot be
・ 5 m fixed tank. placed directly on the shelf.
・ 10m ・ Tank with screw tap (stand included) Material: Stainless steel (4 mesh)

Standard Type
* Not mounted as standard Capacity: 10 L×3 • Large
Stand size: W600×H920×D348 mm Dimensions: W750×H35×D450 mm
・ Tank with nozzle Load capacity: 5 kg (equally distributed load)
Continuous water supply Capacity: 10 L×1 Baskets per shelf: Type 0250: 0
Type 0400: 1
A water circuit to supply pure water
Type 0800: 2
continuously to the chamber.
• Small
・ Pure water coupling with
Dimensions: W350×H35×D270 mm
pressure-reducing valve
Load capacity: 3 kg (equally distributed load)
・ Pure water coupling without
Tank with nozzle Baskets per shelf: Type 0250: 2
pressure-reducing valve
Type 0400: 4
Type 0800: 6
* Do not use when exceeding the shelf load
Tank with screw tap capacity.
(stand included) * Performance may not satisfy guaranteed
values if the air flow is blocked, so please
be sure to have sufficient space around the
Pure water coupling
Shelf, shelf bracket specimen baskets.
(with pressure-reducing valve)
Pure Water Coupling The same with standard accessory.
With Pressure- Without Pressure-
Reducing Valve Reducing Valve
Water 0.05 to 0.50MPa 0.03MPa
pressure (Gauge) (Gauge)
Flow rate 1.3 L/minute or more
Conductivity 0.1 to 10μS/cm
Location Lower left rear side Upper left rear side
Only a steel pipe
Connectable Only a hose can be Model 0250 0400 0800 Floor reinforcement
(or a PVC pipe) can
items connected.
be connected.
W567 W567 W967
Shelf size (mm)
* Water supplier shall be connected by the D450 D750 D750 Increase the floor load capacity of the
customer. Shelf weight 1.4kg 2.2kg 6.6kg inner chamber.
Shelf load capacity
10kg 10kg 30kg • 100 kg
(evenly distributed load)
• 200 kg
Water purifier (WS-1) Support strength* 90kg
• 300 kg
* Including shelf weight Standard specification: 70 kg
Removes all impurities and constantly
creates pure water suitable for
humidifying purposes. Heavy-duty shelf
Conductivity: 10μs/cm or less
Water production capacity: 12 L/h Used to hold heavy specimens ・ Load capacity: 30kg
(Water temperature: 25°C) exceeding the load capacity of the * The shelves fitted to the 0800 model as
Size: W400×H400×D280mm standard shelf. standard components have a load
capacity of 30kg.
・ Load capacity: 50kg
Support Floor load Chamber total Max. Qty.
Load resistance Weight / shelf
strength *2 resistance *3 load resistance *4 in Chamber
0250 ─ 2.7kg
30kg 90kg 70kg 100kg 3
0400 ─ 4.3kg
0250 ─ 3.2kg
50kg *1 100kg 70kg 100kg 0400 ─ 5.1kg 2
0800 ─ 12.1kg
Water leak detection system and dew *1 Including shelf weight
tray (P.10) to catch dripping water are *2 Brackets and supports are changed from standard accessories and brackets must be locked down
by screw.
also available to detect and prevent *3 The floor can be reinforced to support weights up to 300 kg. In this case, the chamber total load
water damages. resistance will also change.
*4 Chamber total load resistance: Sum of the loading weight of all shelves and the floor area loading
weight
8
Rapid-Rate Temperature

Options
Cycle Type

Additional cable port/Door notch Interface Paperless recorder-portable type

・ ø50mm Computer interface A temperature & humidity recorder


・ ø100mm ・ RS-485 that utilizes a liquid-crystal display
・ ø150mm ・ GPIB fitted with a touch-panel.
Standard Type

・ Flat cable port ・ RS-232C Display: 5.7inch color touch panel


・ Door notch H100×D50mm Scan interval: 5 sec. (default)
Internal recording media:
Communication cables Flash memory 8MB
External recording media:
・ RS-485 5m/ 10m/ 30m CF memory card
・ GPIB 2m/ 4m (Supplies with a 256 MB CF card)
USB flash drive
Cable port
< Temperature type >
Specimen temperature control
No. of input channel:
Sensors are attached to the specimen Temperature 1
Cable port rubber plug
to allow exposure tests that provide (5 more channels can be turned ON)
accurate temperature stress to the < Temperature & humidity type >
Prevents air leakage from the cable
specimen. No. of input channel:
port
Temperature 1, Humidity 1
・ ø50mm ・ Insulated type
(4 more channels can be turned ON)
・ ø100mm ・ Non-insulated type
・ ø150mm
・ Spiral-wrapped plug (5×50×2000mm)
・ For the flat cable port
・ For door notch

Recorder output terminal


ø50 mm Spiral-wrapped type

・ Temperature, humidity, and heater


output *ARSF only
This terminals output the
temperature and relative humidity
Flat cable port in the test area.

Door without viewing window

Plain door ideal to test specimens


affected by light.
* There is no lamp installed in the test area
with this option. ・ Dry bulb temperature *ARGF only
Terminal board for dry-bulb sensors
in the chamber.

9
Rapid-Rate Temperature
Options

Cycle Type
Thermocouple Additional overheat protector Trouble buzzer

At tached to specimen to measure Additional preventive measures can be Buzzer notif ication when an er ror
specimen temperature. taken for excessive temperature rise in occurs.
Thermocouple with a brass ball tip the chamber, in addition to the standard

Standard Type
Thermocouple type T (Copper/Copper-Nickel) equipped overheat protector.
・ 2 m SPECIMEN Emergency stop pushbutton
TEMPERATURE INPUT EXTRA OVERHEAT
・ 4 m ( TYPE T ) PROTECTOR
追加温度過昇防止器
試料温度入力
・ 6 m (JIS T ) Stops the chamber immediately.
OPTION
EXTERNAL ALARM
SIGNAL MODE

外部警報出力
TIME SIGNALS
タイムシグナル出力
No.3 OVERCOOL PROTECTOR
温度過冷防止器
No.4 Overcool protector
OPTION
Power
POWERmeter
SUPPLY
SPECIMEN
No.5
MODE
EXTRA OVERHEAT
CONTROL INPUT
TEMPERATURE
FOR SPECIMEN
( TYPE T ) If the temperature inside the chamber
PROTECTOR
試料電源制御出力
試料温度入力 追加温度過昇防止器
This option (JISdisplays
No.1 T) the integral decreases
RECORDERexcessively,
OUTPUT the chamber
stops 記録計用出力
operating to prevent the speci-
OFF
OPTION
power consumption
No.2 of the chamber.
EXTERNAL ALARM
SIGNAL MODE
CHAMBER TEMPERATURE
Display
TIME range: 0 to 9999.99 kWh
SIGNALS 外部警報出力 mens from(TYPE T)being damaged.
タイムシグナル出力 TIME SIGNALS 槽内温度
No.6
External memory: SD memory タイムシグナル出力 card (JIS T )
OVERCOOL PROTECTOR
No.3
No.7
Location: Instrumentation panel 温度過冷防止器 With guard
No.4
No.8 OPTION
* The SD memory card is not supplied.
OPTION
No.5
No.9
POWER SUPPLY
ETHERNET MODE

CONTROL MONITOR OUTPUT


Chamber dew tray
FOR SPECIMEN No.10 (1-5V DC LINEAR )
試料電源制御出力 モニタ出力 ( DC1-5V リニア )
Wet bulb No.1
wick RECORDER OUTPUT
記録計用出力 OFF

No.2 OPTION Prevents water leaks from the chamber


Fineタイムシグナル出力
wick
TIME SIGNALSof the same kind as the Status indicator light
CHAMBER TEMPERATURE
(TYPE T)
onto the floor.
No.6 槽内温度
accessories. (JIS T )

FW-5 (24 wicks)


No.7 Please select lighted or blinking, and
No.8 requirement
OPTION of buzzer sound.

ETHERNET
No.9
No. of levels: 3
No.10 MONITOR OUTPUT
(1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア )

OPTION

Image

Alarm output terminal


Operation manual
If the safety device of the chamber is
activated, alarm signal will be sent to ・CD
remote location through this terminal. ・Booklet
Signal: terminal is closed on abnormal Rotating signal light
situation
Reports & certificates
Accessory: plug The rotating signal lights up when an
Location: in the control board error occurs. ・ Testing and inspection report
*The circuit shall be connected by customer. Color of the signal: ・ Test data
・Red ・ Temperature (& humidity)
・Yellow uniformity measurement
・ Calibration report
・ Calibration certificate
・ Traceability certificate
・ Traceability system chart

10
Rapid-Rate Temperature

Features
Cycle Type

ARS・ARL・ARG・ARU
Temperature & Humidity Control Range
Standard Type
(In environment of ambient temperature of +23℃, no specimen.)
ARSF
100 98
90
80 Temperature & Humidity Range
70
Standard Type

Relative 60
Minimum temp.: -45°C/-75°C
Humidity 50 Maximum temp.: +180°C
(%rh)
40
Humid. (ARL & ARS only): 10 to 98%rh
30
20
10 Temperature Change Rate
0 Approx. 3K/min., with 50kg of
10 20 30 40 50 60 70 80 90 100
15 65 95 specimen*, -75⇔ +180°C. (ARS-1100)
Temperature (℃) This can also be used for acceleration
testing.
*Specimen as aluminum, including 12kg of
shelf

Specimen Temperature Control


Temperature & Humidity Control Range (Standard)
(In environment of ambient temperature of +20℃, no specimen.) Attaching a temperature measurement
100 98 sensor to the specimen enables the
90 temperature of the specimen to be
80 monitored and controlled, which makes
Relative 70 ARS・ARL
tests even more accurate.
Humidity 60
(%rh) 50
40
Heat Load up to 4500W
30
20 Allowable heat load is different depends
10 on models and operation conditions.
0 (Page 14 to 17)
10 20 30 40 50 60 70 80 90 100 *For your safety, please be sure to connect the
Temperature (℃) 95
power through specimen power supply
* Continuous operation at or below +40℃ is limited because of frost formation on the cooler control terminal.
and dehumidifier. *Temperature-triggered circuit breaker is
available (customized option).

Temperature Change Rate


Temperature Change Rate
Model Capacity Temp. range
Heat up rate Pull down rate
ARS/ARG −49.5⇔154.5℃
-0220 220L 6.0℃ /min
PR・PL・PSL 5.2℃ /min
-0390 390L 5.0℃ /min 4.0℃ /min
−75 to +180℃
-0680 680L 6.0℃ /min 4.2℃ /min
-1100 1100L 4.7℃ /min 4.1℃ /min
ARL/ARU −22.5⇔157.5℃
-0680 680L 6.3℃ /min 4.8℃ /min
−45 to +180℃
-1100 1100L 4.7℃ /min 4.4℃ /min
* ARS, ARL : temperature & humidity
* ARG, ARU : temperature only

11
Rapid-Rate Temperature
Features

Cycle Type
ARS・ARL・ARG・ARU

ø100mm Cable Ports on Both


Sides
ø100mm cable ports are fitted as
standard to enable easy access to the

Standard Type
inside of the chamber from the left and
the right.

Large Viewing Window (Option)


The chamber lamp (halogen lamp)
facilitates visibility within the chamber.

Size of Viewing Window


W340×H440mm

Water Supply System


The back of the chamber is fitted with a Cable ports on both sides
water suction port connected directly to
the pure water, and the front of the
chamber is fitted with a water tank.

Door Locks
Locks have been fitted on the doors for
convenience in order to prevent the door
from opening during testing and to
ensure careful management of
specimens and tests. Viewing window (option) Chamber lamp

International Test Standards


Conforms to IEC60068-2, ISO16750-4
(5.3) and other representative
environmental testing standards.
(Test standard list below)

Global Safety Standards


ISO12100 (Safety of machinery) Water tank Key
ISO14121 (Risk assessment)
IEC61000-6-2, IEC61000-6-4 (EMC)
EN50581 (RoHS) ● Test Standard Conformance
CE marking (For marked models & ・IEC 60068-2-1: Cold
power voltage, see page 14 to 17.)
・IEC 60068-2-2: Dry heat
・IEC 60068-2-14: Change of temperature with
specified rate of change
・IEC 60068-2-38: Composit temperature/humidity cyclic test
・IEC 60068-2-78: Damp heat,steady state
・ISO 16750-4 (5.3): Road vehicles (Temperature cycling)

12
PC
PC
Ethernet Intranet
(company LAN) 携帯電話
Rapid-Rate Temperature

スマートフォン

Controller
Mail server
Cycle Type

AR series Mobile phone Environmental


Stress Chamber ARS・ARL・ARG・ARU
タブレットコントローラー
(オプション)

N instrumentation P-310
Program Copy and Computer Editing
Chamber lamp Color LCD Touch Panel
Standard Type

A 7-inch wide color LCD fitted with


Copy LED backlight. Tabs are displayed at
the bottom of the screen to help access
to other screens.

Edit
Chamber Lamp ON/OFF
The chamber lamp can be switched ON
小型環境試験器
and OFF from all screens. (Wi-Fi 機能搭載)

Multilingual Support
Touch navigation The language used by the instrumentation
Touch icon to show can be changed with the screen settings
Network navigation bar. 無線 LAN による接続例
(Japanese / English / Chinese
(simplified / traditional) / Korean). Wi-Fi ルーター
Wi-Fi router (オプション)

Information Function
PC The INFO icon will blink when chamber Ethernet
Ethernet
information requiring attention. スマートフ
小型環境試験器
・ Inspection Period Notifications
Smartphone Tablet controller
It is possible to randomly preset the
内蔵ワイヤレスダイレク トによ
AR series
period and details of inspections for
ワイヤレスダイレクト
humidifier plates and condenser(オプション)
filters.

Registering Test Patterns


Information Program operation: 40 patterns (99 steps
per program) 小型環境試験器

Constant operation: 3 patterns


Program Copy and Computer Editing

Test Data Records


Temperature & humidity settings and
Copy measurement スマートフォン
values can be recorded on
the internal memory and external
memories.

Standard Type Rapid-Rate


Temperature Cycle Type Program Pattern Copying
Edit It is possible to copy program patterns
* Some items may not be copied between different models and chambers with
between chambers with the use of USB
different options. flash drives without the need for PC
operations.
(USB flash drives not supplied.)

13
Rapid-Rate Temperature
ARL −45 to +180℃・10 to 98%rh

Cycle Type
TEMPERATURE & HUMIDITY CHAMBER

Model ARL−0680 ARL−1100


System Balanced Temperature & Humidity Control (BTHC) system
Temp. range −45 to +180℃ (−49 to +356℉)
Temp. fluctuation ±0.3K

Standard Type
Temp. variation in space 3.0K
Temp. performance *1

Temp. rate Heat up rate 6.3 K/min. 4.7 K/min.


of change *2 Pull down rate 4.8 K/min. 4.4 K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 30 min. Within 40 min.
achievement +20 to −45℃
time Pull down time
Within 50 min. Within 50 min.
Max. allowable heat load 4500 W Test area temperature: +20℃
Temp. & humid. range +10 to +95℃ / 10 to 98%rh
Temp. & humid.
performance *1

Humid. fluctuation ±2.5%rh


Max. allowable heat load 500 W Test area conditions: +85℃ /85%rh
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Heater Nichrome strip wire heater (3 kW×2)
Humidifier Sheathed heater
Cooler Plate fin cooler and dehumidifier
Construction

Water tank capacity 40L


System Mechanical single-stage refrigeration system
Refrigeration unit

Scroll-type
Compressor
3.0 kw 3.75 kw
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 510 kg 600 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz 53 A 56 A

Power 220V AC 3φ60Hz 49 A 52 A


supply *4 380V AC 3φ50Hz 23 A 25 A
400V AC 3φ50Hz *5 22 A 23 A
Noise level *6 61 dB 62 dB
Exhaust heat quantity kJ/h (kcal/h) 32400 (7743) 39600 (9464)
*1: At ambient temperature +20℃, no specimen. Performance shown *4: Power supply voltage fluctuation to be ±10% of rated value.
above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. *5: Conforms to CE marking based on EU directives.
*2: Temperature rate of change in the temperature range excluding ±10% *6: Measurements are to be taken in an anechoic room at a height of 1.2m
of max/min. temperature. from the floor and a distance of 1m from the chamber front panel
*3: Excluding protrusions. (ISO 1996-1:2003 _ A-weighted sound pressure level).
14
Rapid-Rate Temperature

ARS −75 to +180℃・10 to 98%rh


Cycle Type

TEMPERATURE & HUMIDITY CHAMBER

Model ARS−0220 ARS−0390 ARS−0680 ARS−1100


System Balanced Temperature & Humidity Control (BTHC) system
Temp. range −75 to +180℃ (−103 to +356℉)
Temp. fluctuation ±0.3K
Temp. variation in space 3.0K
Standard Type

Temp. performance *1

Temp. rate Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
of change *2 Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 35 min. Within 45 min. Within 30 min. Within 40 min.
achievement +20 to −75℃
time Pull down time
Within 40 min. Within 50 min. Within 50 min. Within 50 min.
Test area temperature: +20℃
Max. allowable heat load
3000 W 4500 W
Temp. & humid. range +10 to +95℃ / 10 to 98%rh
Temp. & humid.
performance *1

Humid. fluctuation ±2.5%rh


Test area conditions: +25 to +95℃ /90%rh Test area conditions: +85℃ /85%rh
Max. allowable heat load
350 W 300 W 500 W
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Nichrome strip wire heater
Heater
(1.75 kW×2) (3 kW×2)
Humidifier Sheathed heater
Cooler Plate fin cooler and dehumidifier
Construction

Water tank capacity 40L


System Mechanical cascade and compression refrigeration system
Refrigeration unit

Rotary-type Scroll-type
Compressor Unit 1: 3.0 kw ×1, Unit 1: 3.75 kw ×1,
Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1
Unit 2: 3.0 kw ×1 Unit 2: 3.75 kw ×1
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
W700×H800×D400 W700×H800×D700 W850×H1000×D800 W1100×H1000×D1000
Inside dimensions mm (inch) *3
(W27.6×H31.5×D15.8) (W27.6×H31.5×D27.6) (W33.5×H39.4×D31.5) (W43.3×H39.4×D39.4)
W900×H1742×D1455 W900×H1742×D1705 W1050×H1955×D1805 W1300×H1955×D2005
Outside dimensions mm (inch) *3
(W35.4×H68.6×D57.3) (W35.4×H68.6×D67.1) (W41.3×H77.0×D71.1) (W51.2×H77.0×D78.9)
Weight 390 kg 405 kg 615 kg 700 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz ─ ─ 63 A 70 A
Power 220V AC 3φ60Hz 38 A 38 A 58 A 64 A
supply *4 380V AC 3φ50Hz 24 A 24 A 28 A 32 A
400V AC 3φ50Hz *5 23 A 23 A 27 A 29 A
Noise level *6 57 dB 58 dB 62 dB 63 dB
Exhaust heat quantity kJ/h (kcal/h) 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185)
*1: At ambient temperature +20℃, no specimen. Performance shown *3: Excluding protrusions.
above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. *4: Power supply voltage fluctuation to be ±10% of rated value.
*2: Temperature rate of change in the temperature range excluding ±10% *5: Conforms to CE marking based on EU directives.
of max/min. temperature. *6: Measurements are to be taken in an anechoic room at a height of 1.2m
15 from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
Rapid-Rate Temperature
ARU −45 to +180℃

Cycle Type
TEMPERATURE CHAMBER

Model ARU−0680 ARU−1100


System Balanced Temperature Control (BTC) system
Temp. range −45 to +180℃ (−49 to +356℉)
Temp. fluctuation ±0.3 K

Standard Type
Temp. variation in space 3.0 K
Temp. performance *1

Temp. rate Heat up rate 6.3 K/min. 4.7 K/min.


of change *2 Pull down rate 4.8 K/min. 4.4 K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 30 min. Within 40 min.
achievement +20 to −45℃
time Pull down time
Within 50 min. Within 50 min.
Max. allowable heat load 4500 W Test area temperature: +20℃
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Heater Nichrome strip wire heater (3kW ×2)
Cooler Plate fin cooler
Construction

System Mechanical single-stage refrigeration system


Refrigeration unit

Scroll-type
Compressor
3.0 kw 3.75 kw
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 505 kg 595 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz 53 A 56 A

Power 220V AC 3φ60Hz 49 A 52 A


supply *4 380V AC 3φ50Hz 23 A 25 A
400V AC 3φ50Hz *5 22 A 23 A
Noise level *6 61 dB 62 dB
Exhaust heat quantity kJ/h (kcal/h) 32400 (7743) 39600 (9464)
*1: At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001.
*2: Temperature rate of change in the temperature range excluding ±10% of max/min. temperature.
*3: Excluding protrusions.
*4: Power supply voltage fluctuation to be ±10% of rated value.
*5: Conforms to CE marking based on EU directives.
*6: Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).

16
Rapid-Rate Temperature

ARG −75 to +180℃


Cycle Type

TEMPERATURE CHAMBER

Model ARG−0220 ARG−0390 ARG−0680 ARG−1100


System Balanced Temperature Control (BTC) system
Temp. range −75 to +180℃ (−103 to +356℉)
Temp. fluctuation ±0.3 K
Standard Type

Temp. variation in space 3.0 K


Temp. performance *1

Temp. rate Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
of change *2 Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 35 min. Within 45 min. Within 35 min. Within 45 min.
achievement +20 to −75℃
time Pull down time
Within 40 min. Within 50 min. Within 50 min. Within 50 min.
Test area temperature: +20℃
Max. allowable heat load
3000 W 4500 W
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Nichrome strip wire heater
Heater
(1.75 kW×2) (3 kW×2)
Cooler Plate fin cooler
Construction

System Mechanical cascade refrigeration system


Refrigeration unit

Scroll-type
Compressor Unit 1: 2.2 kw ×1, Unit 1: 3.0 kw ×1, Unit 1: 3.75 kw ×1,
Unit 2: 2.2 kw ×1 Unit 2: 3.0 kw ×1 Unit 2: 3.75 kw ×1
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
W700×H800×D400 W700×H800×D700 W850×H1000×D800 W1100×H1000×D1000
Inside dimensions mm (inch) *3
(W27.6×H31.5×D15.8) (W27.6×H31.5×D27.6) (W33.5×H39.4×D31.5) (W43.3×H39.4×D39.4)
W900×H1742×D1455 W900×H1742×D1705 W1050×H1955×D1805 W1300×H1955×D2005
Outside dimensions mm (inch) *3
(W35.4×H68.6×D57.3) (W35.4×H68.6×D67.1) (W41.3×H77.0×D71.1) (W51.2×H77.0×D78.9)
Weight 385 kg 400 kg 615 kg 700 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements

200V AC 3φ50/60Hz ─ ─ 63 A 70 A

Power 220V AC 3φ60Hz 38 A 38 A 58 A 64 A


supply *4 380V AC 3φ50Hz 24 A 24 A 28 A 32 A
400V AC 3φ50Hz *5 23 A 23 A 27 A 29 A
Noise level *6 57 dB 58 dB 62 dB 63 dB
Exhaust heat quantity kJ/h (kcal/h) 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185)
*1: At ambient temperature +20℃, no specimen. Performance shown *4: Power supply voltage fluctuation to be ±10% of rated value.
above conforms to IEC 60068-3-5:2001. *5: Conforms to CE marking based on EU directives.
*2: Temperature rate of change in the temperature range excluding ±10% *6: Measurements are to be taken in an anechoic room at a height of 1.2m
of max/min. temperature. from the floor and a distance of 1m from the chamber front panel
*3: Excluding protrusions. (ISO 1996-1:2003 _ A-weighted sound pressure level).

17
Rapid-Rate Temperature
Options

Cycle Type
Power cable Shelf, shelf bracket

・ 2.5 m Equivalent to standard accessory.


・5 m
・ 10m

Standard Type
* The chamber does not come with a power
cable.

Water purifier (WS-1)

Water purifier with reverse osmosis


membrane. Produces approx 6.6L per Model 0220 0390 0680 1100
hour (at primary water temp. +10℃). Shelf size (W×Dmm) 667×350 667×650 817×750 1067×950
Shelf weight 2 kg 3 kg 6 kg 12 kg
Shelf load capacity
30 kg 30 kg 40 kg 50 kg
(evenly distributed load)

Support strenght * 50 kg 80 kg 80 kg 100 kg

* Including shelf weight

Heavy-duty shelf Interface

Used to hold heavy specimens Computer interface


Water leak detection system and
exceeding the load capacity of the ・ RS-485
dew tray to catch dripping water standard shelf. ・ GPIB
are also available to detect and * Standard for 1100L model ・ RS-232C
prevent water damages. Model 0220 0390 0680

Load capacity 50 kg
Shelf weight 3 kg 4 kg 8 kg
Communication cables
Additional cable port
Support strength 80 kg
・ RS-485 5m/ 10m/ 30m
Provided in addition / replacement of Safety precautions ・ GPIB 2m/ 4m
the standard cable ports.
● Do not use specimens which are explosive or flammable,
・ 50 mm diameter Viewing window
or which contain such substances. To do so could be
・ 100 mm diameter hazardous, as this may lead to fire or explosion.
* Each cable port is equipped with a silicone Used fornot
● Do observation of the
place corrosive specimens
materials in the chamber. If
sponge rubber plug. insidecorrosive
the chamber.
substances or liquid is used, the life of the unit
may be significantly
Dimensions: W340×H440 shortened
mm specifically because of the
corrosion of stainless steel, resin and silicone materials.
● Do not use living organisms or items that exceed the
allowable heat load as a specimen.
● Be sure to read the operation manual before operation.

Please contact us for non-standard specification.

Cable port rubber plug Safety precautions


● Do not use specimens which are explosive or flammable, or which contain such
Prevents air leakage from the cable substances. To do so could be hazardous, as this may lead to fire or explosion.
port. ● Do not place corrosive materials in the chamber. If corrosive substances or liquid is
used, the life of the unit may be significantly shortened specifically because of the
corrosion of stainless steel, resin and silicone materials.
● Do not use living organisms or items that exceed the allowable heat load as a
specimen.
● Be sure to read the operation manual before operation.

Please contact us for non-standard specification. 18


Rapid-Rate Temperature

Options
Cycle Type

Paperless recorder - portable type Additional overheat protector Trouble buzzer

A temperature & humidity recorder Additional preventive measures can be If a trouble occurs, the buzzer will alert
that utilizes a liquid-crystal display taken for excessive temperature rise in you of the situation.
fitted with a touch-panel. the chamber, in addition to the standard
Standard Type

Display: 5.7inch color touch panel equipped overheat protector.


Scan interval:
SPECIMEN 5 sec. (default) EXTRA OVERHEAT
Rotating signal lamp
TEMPERATURE INPUT
Internal recording
( TYPE T ) media: PROTECTOR
追加温度過昇防止器
試料温度入力
Flash memory (JIS T ) 8MB The lamp lights up when alarm triggers.
External recording media: EXTERNAL ALARM
SIGNAL
OPTION
MODE
(Red or yellow)
CF memory card 外部警報出力
TIME SIGNALS
(Supplies with a 256 MB CF card)
タイムシグナル出力
OVERCOOL PROTECTOR
No.3
USB flash drive 温度過冷防止器
No.4 Overcool protector
< Temperature type > No.5
OPTION
POWER SUPPLY
SPECIMEN MODE
EXTRA OVERHEAT
No. ofFORinput
CONTROL
TEMPERATURE
SPECIMEN
channel:
( TYPE T )
INPUT
If the temperature inside the chamber
PROTECTOR
追加温度過昇防止器
Temperature
試料電源制御出力試料温度入力
(JIS T )
1 decreases excessively, the chamber
RECORDER OUTPUT
No.1
(5 more channels can be turned
EXTERNAL ALARMON)
記録計用出力
stops operating
OPTION
to prevent the speci-
OFF

No.2 SIGNAL
< Temperature
TIME SIGNALS & humidity外部警報出力type >
MODE
CHAMBER TEMPERATURE
mens from being damaged.
(TYPE T)
No. of input channel:
タイムシグナル出力 TIME SIGNALS
タイムシグナル出力
No.6 槽内温度
(JIS T )
OVERCOOL PROTECTOR
Temperature 1, Humidity 1 No.3 No.7
温度過冷防止器
(4 more channels can be turned No.8 ON)
No.4 OPTION
OPTION
No.5
No.9
POWER SUPPLY
ETHERNET MODE

CONTROL MONITOR OUTPUT


FOR SPECIMEN No.10 (1-5V DC LINEAR )
試料電源制御出力 モニタ出力 (DC1-5V リニア )
No.1 RECORDER OUTPUT
記録計用出力 OFF

No.2 OPTION
TIME SIGNALS External alarm terminal
CHAMBER TEMPERATURE
(TYPE T) Operation manual
タイムシグナル出力 槽内温度
No.6
(JIS T )
No.7 If the safety device of the chamber is ・ CD
No.8 activated,OPTIONalarm signal will be sent to ・ Booklet
SPECIMEN
ETHERNET
No.9
TEMPERATURE
( TYPE T )
INPUT remote location through this EXTRA terminal.
OVERHEAT
PROTECTOR
No.10 MONITOR OUTPUT 追加温度過昇防止器
試料温度入力 (1-5V DC LINEAR )
(JIS T )
モニタ出力 (DC1-5V リニア )
Temperature recorder (digital) EXTERNAL ALARM
OPTION Reports & certificates
SIGNAL MODE

外部警報出力 OPTION
Portable type TIME SIGNALS
タイムシグナル出力
・ Testing and inspection report
−100 to +200℃ 6 dots ・ Test data
No.3 OVERCOOL PROTECTOR
温度過冷防止器

・ Temperature (& humidity) uniformity


No.4
OPTION
No.5
POWER SUPPLY
CONTROL
MODE
measurement
Temperature and humidity recorder (digital)
試料電源制御出力
FOR SPECIMEN
・ Calibration report
・ Calibration certificate
No.1 RECORDER OUTPUT
記録計用出力 OFF

Portable type No.2


TIME SIGNALS
CHAMBER TEMPERATURE
(TYPE T )
・ Traceability certificate
−100 to +200℃ / 0 to 100%rh
タイムシグナル出力6 dots Emergency
No.6
stop switch槽内温度 ・ Traceability system chart
(JIS T )
No.7

Stops the
No.8
chamber immediately.
OPTION

No.9
ETHERNET
No.10 MONITOR OUTPUT
(1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア )

OPTION

200V AC, 220V AC spec. 380V AC, 400V AC spec.

19
Network
* Requires an intranet Supported browser: Internet Explorer 11

Chambers Can be Operated from PCs and Tablet Terminals

Remote Monitoring and


Control (Ethernet Connection)
The chambers are equipped with unique
web applications that enable chamber
status to be confirmed and operated
from a web browser screen (PC or tablet
terminal). It is also possible to start
operations with a PC or other device
from a remote location.

Editing Test Profiles with a


Browser Image
It is possible to edit the program
patterns registered in the testing Login privileges
chamber with a web browser. Screen Constant/
Chamber monitor Run/Stop Configuration
Privileges Program setup
Administrator
Displaying Data in Graphs Operator
Settings and measurement values saved User インターネット
試験室

in the testing chamber can be displayed A

as graphs on a web browser. (別売)


イントラネット
Email alert
E-mail Notifications
Details on alarms that have been
triggered will be sent to pre-registered オフィス 試験室
B
PC
e-mail addresses. It is also possible to Ethernet Intranet ネットワーク
カメラ
transmit e-mails when testing has (company
他社メーカー試験器 LAN)
計測器

finished.
* An Intranet environment is required to Mail server
transmit e-mails.
AR series Mobile phone En
Stre

ESPEC OnlineCore Program Copy


Internet
and Test
Computer Editing
area
A

(Sold separately)
Copy
Intranet

Central control system recommended for


multiple environmental
test chambers installations
Test
Offices
Edit area
B

Network
camera
Measuring
Test chambers of instrument
other manufacturers

*Please contact ESPEC for more information, about which products can be connected.

20
Network
OTHER PRODUCTS

RAPID-RATE THERMAL CYCLE CHAMBER


Interior dimensions
Model Temperature range
W×H×Dmm
TCC-150W −70 to +180℃ 800×500×400

FASTER TEMPERATURE (& HUMIDITY) CHAMBER


Interior dimensions
Model Temperature & humidity range
W×H×Dmm
SML-2 −40 to +180℃ / 20 to 98%rh

SMU-2 −40 to +180℃


1200×1000×1500
SMS-2 −70 to +180℃ / 20 to 98%rh

SMG-2 −70 to +180℃

THERMAL SHOCK CHAMBER TSD (Elevator Type)


Test area dimensions
Model Temperature range
W×H×Dmm

High temp. chamber:


+60 to +205℃
TSD-101-W 710×345×410
Low temp. cahamber:
−77 to 0℃
● +300℃ specification is also available.

21
OTHER PRODUCTS

THERMAL SHOCK CHAMBER TSA (Damper Type)


Test area dimensions
Model Temperature exposure range
W×H×Dmm

TSA-43EL 240×460×370

TSA-73EL High temp.: 410×460×370


Ambient +50 to +200℃
TSA-103EL 650×460×370
Low temp.:
TSA-203EL −65 to 0℃ 650×460×670

TSA-303EL 970×460×670

TSA-73ES 410×460×370
High temp.:
TSA-73EH +60 to +200℃ 410×460×370

TSA-103ES Low temp.: 650×460×370


−70 to 0℃
TSA-203ES 650×460×670
● +300℃ specification is also available.

THERMAL SHOCK CHAMBER WITH HUMIDITY TSA (Damper Type)


Test area dimensions
Model Test area
W×H×D mm

Hot exposure ranfe:


Thermal cycle test:
TSA-102D-W +70 to +150℃ 650×460×370
Dew cycle test:
−10 to +100℃
Cold exposure ranfe:
Thermal cycle test:
TSA-202D-W −70 to +10℃ 650×460×670
Dew cycle test:
−40 to +10℃

THERMAL SHOCK CHAMBER TSE (Elevator Type)


Test area dimensions
Model Temperature range
W×H×D mm

High temp. chamber:


+60 to +200℃
TSE-12 320×148×230
Low temp. chamber:
−65 to 0℃
● +300℃ specification is also available.

22
http://www.espec.co.jp/english
Head Office
3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan
Tel : 81-6-6358-4741 Fax : 81-6-6358-5500

ESPEC NORTH AMERICA, INC.


Tel : 1-616-896-6100 Fax : 1-616-896-6150
ESPEC EUROPE GmbH
Tel : 49-89-1893-9630 Fax : 49-89-1893-96379
ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD.
Head Office
Tel : 86-21-51036677 Fax : 86-21-63372237
BEIJING Branch
Tel : 86-10-64627025 Fax : 86-10-64627036
TIANJIN Branch
Tel : 86-22-26210366 Fax : 86-22-26282186
GUANGZHOU Branch
Tel : 86-20-83317826 Fax : 86-20-83317825
SHENZHEN Branch
Tel : 86-755-83674422 Fax : 86-755-83674228
SUZHOU Branch
Tel : 86-512-68028890 Fax : 86-512-68028860
ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD.
Tel : 86-21-68798008 Fax : 86-21-68798088
ESPEC ENGINEERING (THAILAND) CO., LTD.
Tel : 66-0-3-810-9353 Fax : 66-0-3-810-9356

Quality Management System Assessed Environmental Management System Assessed


and Registered and Registered
ESPEC CORP. has been assessed by and ESPEC CORP.
registered in the Quality Management System (Overseas subsidiaries not included)
based on the International Standard ISO
9001:2008 (JIS Q 9001:2008) through the
Japanese Standards Association (JSA).
*Registration : ESPEC CORP.
(Overseas subsidiaries not included)

● Specifications are subject to change without notice due to design improvements.


TS6E29C03 (The contents of this catalog is as of June, 2017.) ● Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.