Professional Documents
Culture Documents
AR series
CAT.NO.E16141
Rapid Temperature Changes of 18K/min.
Environmental stress chambers that carve a path into the future of environmental testing.
The pursuit of reliability requires speed in providing results within limited periods of
time and the accurate reproduction of environments.
This chamber series support heat load from specimens, and provide superior levels of
temperature change performance and wide temperature & humidity control range.
The lineup consists of twenty chambers that can be selected in accordance
with temperature & humidity range, inside capacity and temperature change rate.
Temperature change rate is between 4K/minute and 18K/minute, which conforms to
IEC standards and test standards for automotive parts.
The processing speed of the new instrumentation has been greatly improved,
and connecting the chambers to an Ethernet enables the operation status to be monitored
and managed remotely from your desk.
Contains all areas of performance demanded by constant temperature & humidity chambers.
Contents
● Rapid-Rate Temperature Cycle Type P.3-10
● Standard Type P.11-19
● Network P.20
● Other products P.21-22
ARSF−0250−15
ARSF−0400−15
ARSF−0800−15
1
Model Lineup Boasting Superior Temperature Change Performance
Rapid-Rate Temperature Cycle Type
Standard Type
20
ARSF/ARGF-0250-15
TCC-150W
Rapid-Rate Thermal
Cycle Chamber
15 ARSF/ARGF-0400-15 ARSF/ARGF-0800-15
Temperature pull-down rate (℃ / min.)
10 ARSF/ARGF-0400-10 ARSF/ARGF-0800-10
ARSF/ARGF
-0250-10
ARL/ARU
-0680 ARL/ARU
5 ARS/ARG-0220 -1100
SH/SU-242-5
Bench-Top Type
Temperature(& Humidity) ARS/ARG ARS/ARG
ARS/ARG
Chamber -0680 -1100
-0390
Features
Cycle Type
ARSF・ARGF
Cycle Type
ARSF・ARGF
Standard Type
sensor to the specimen enables the
temperature of the specimen to be
monitored and controlled, which makes
tests even more accurate.
Door Locks
Locks have been fitted on the doors for
convenience in order to prevent the door
from opening during testing and to Water tank Key
ensure careful management of
specimens and tests. ● Test Standard Conformance
・IEC 60068-2-1: Cold
Global Safety Standards ・IEC 60068-2-2: Dry heat
・IEC 60068-2-14: Change of temperature with specified rate of change
ISO12100 (Safety of machinery)
・IEC 60068-2-30: Damp heat,cyclic
ISO14121 (Risk assessment)
・IEC 60068-2-38: Composit temperature/humidity cyclic test
IEC61000-6-2, IEC61000-6-4 (EMC)
・IEC 60068-2-78: Damp heat,steady state
EN50581 (RoHS)
・IEC 61747 (5.2.7): Liquid crystal and solid-state display devices
CE marking (For marked models & Environmental,endurance and mechanical test
power voltage, see page 6 to 7.) ・ISO 16750-4 (5.3): Road vehicles (Temperature cycling)
4
Rapid-Rate Temperature
Email alert
Controller
Cycle Type
PC ARSF・ARGF
PC
Ethernet Intranet
Information Function
The INFO icon will blink when chamber
小型環境試験器
(Wi-Fi 機能搭載)
information requiring attention.
・ Inspection Period Notifications
It is possible to randomly preset the
period and details of inspections for
humidifier plates and condenser
Network filters. 無線 LAN による接続例
・ Inspection Notifications Wi-Fi ルーター
Wi-Fi router When the monitoring value goes over (オプション)
the threshold, this notifications
encourage inspection.
Information Monitor objects:
Ethernet
PC compressor amperage & condenser Ethernet
cooling-water temperature. スマートフ
小型環境試験器
Smartphone Tablet controller
AR series 内蔵ワイヤレスダイレクトによ
Registering Test Patterns
ワイヤレスダイレクト
(オプション)
Program operation: 40 patterns (99 steps
per program)
Constant operation: 3 patterns
Copy
Program Pattern
スマートフォンCopying
It is possible to copy program patterns
between chambers with the use of USB
flash drives without the need for PC
Standard Type Rapid-Rate operations.
Temperature Cycle Type
(USB flash drives not supplied.)
Edit
* Some items may not be copied between different models and chambers with
5 different options.
Rapid-Rate Temperature
ARSF −70〜+180℃・10〜98%rh
Cycle Type
TEMPERATURE & HUMIDITY CHAMBER
Standard Type
Temperature variation in space −70 to +150℃: 1.5K, +150.1 to +180℃: 2.0K
Temp. performance *1
Temp. rate Heat up rate 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min.
of change Pull down rate 10K/min. 18K/min. 10K/min. 15K/min. 10K/min. 15K/min.
+20℃ to +180℃
Temperature Heat up time
extremes 20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
achievement +20℃ to −70℃
time Pull down time
20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
Allowable heat load *2 6000W 9000W
Temp. & humid. range +10 to 95℃/ 10 to 98%rh
Temp. & humid.
performance *1
Compressor
4.47kW×4.47kW 5.59kW×5.59kW 4.47kW×4.47kW 5.59kW×5.59kW 9.69kW×9.69kW
Condenser Water-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A/R508A
Capacity 249L 398L 784L
Chamber total load capacity 100kg (shelf support pole: 90kg, floor: 70kg)
Inside dimensions mm *3 600×830×500 600×830×800 1000×980×800
Outside dimensions mm *3 800×1703×1900 800×1703×2200 1200×1853×2200
Weight 725kg 730kg 750kg 755kg 910kg 1000kg
Drain hose, 50mm cable port (x2, one on the right & left sides), chamber lamp,
casters ×4 (with leveling feet), time signal terminal ×2, specimen power supply control terminal,
Equipment
Ethernet port (LAN port), USB memory port,
viewing window (effective view 0250,0480: W180×H260(mm) 0800: W295×H380(mm))
Shelf (18Cr-8Ni stainless steel), shelf brackets (18Cr-8Ni stainless steel), key (×2 For door),
Accessories cable port rubber plug (φ50mm ×2), breaker handle stopper , wet bulb wick,
cartridge fuse (7A ×3, 3A ×1), Operation manual *Power cable is not included.
Ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
ARGF −70〜+180℃
Cycle Type
TEMPERATURE CHAMBER
Temp. rate Heat up rate 10K/ min. 18K/ min. 10K/ min. 15K/ min. 10K/ min. 15K/ min.
of change Pull down rate 10K/ min. 18K/ min. 10K/ min. 15K/ min. 10K/ min. 15K/ min.
+20℃ to +180℃
Temperature Heat up time
extremes 20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
achievement +20℃ to −70℃
time Pull down time
20 min. 15 min. 20 min. 15 min. 20 min. 15 min.
Allowable heat load *2 6000W 9000W
Exterior material Stainless steel plate: 18 Cr stainless steel plate, hairline finish
Test area material Stainless steel plate: 18−8 Cr−Ni stainless steel plate, 2B polish
Heater Nichrome strip wire heater
Cooler Plate fin cooler
System Mechanical cascade refrigeration
Scroll-type
Refrigerator
Compressor
4.47kW×4.47kW 5.59kW×5.59kW 4.47kW×4.47kW 5.59kW×5.59kW 9.69kW×9.69kW
Condenser Water-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A/R508A
Capacity 249L 398L 784L
Chamber total load capacity 100kg (shelf support pole: 90kg, floor: 70kg)
Inside dimensions mm *3 600×830×500 600×830×800 1000×980×800
Outside dimensions mm *3 800×1703×1900 800×1703×2200 1200×1853×2200
Weight 715kg 720kg 740kg 745kg 900kg 990kg
Drain hose, cable port (I.D. φ50 mm on the left/right side), chamber lamp,
casters ×4 (with leveling feet), time signal terminal ×2, specimen power supply control terminal,
Equipment
Ethernet port (LAN port), USB memory port,
viewing window (effective view 0250,0480: W180×H260(mm) 0800: W295×H380(mm))
Shelf (18Cr-8Ni stainless steel), shelf brackets (18Cr-8Ni stainless steel), key (×2 For door),
Accessories cable port rubber plug (φ50mm ×2), breaker handle stopper , wet bulb wick,
cartridge fuse (7A ×3, 3A ×1), Operation manual *Power cable is not included.
Ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
7
Rapid-Rate Temperature
Options
Cycle Type
Power cable Water tank Specimen basket
・ 2.5 m For supplying water to the chamber’s For small specimens that cannot be
・ 5 m fixed tank. placed directly on the shelf.
・ 10m ・ Tank with screw tap (stand included) Material: Stainless steel (4 mesh)
Standard Type
* Not mounted as standard Capacity: 10 L×3 • Large
Stand size: W600×H920×D348 mm Dimensions: W750×H35×D450 mm
・ Tank with nozzle Load capacity: 5 kg (equally distributed load)
Continuous water supply Capacity: 10 L×1 Baskets per shelf: Type 0250: 0
Type 0400: 1
A water circuit to supply pure water
Type 0800: 2
continuously to the chamber.
• Small
・ Pure water coupling with
Dimensions: W350×H35×D270 mm
pressure-reducing valve
Load capacity: 3 kg (equally distributed load)
・ Pure water coupling without
Tank with nozzle Baskets per shelf: Type 0250: 2
pressure-reducing valve
Type 0400: 4
Type 0800: 6
* Do not use when exceeding the shelf load
Tank with screw tap capacity.
(stand included) * Performance may not satisfy guaranteed
values if the air flow is blocked, so please
be sure to have sufficient space around the
Pure water coupling
Shelf, shelf bracket specimen baskets.
(with pressure-reducing valve)
Pure Water Coupling The same with standard accessory.
With Pressure- Without Pressure-
Reducing Valve Reducing Valve
Water 0.05 to 0.50MPa 0.03MPa
pressure (Gauge) (Gauge)
Flow rate 1.3 L/minute or more
Conductivity 0.1 to 10μS/cm
Location Lower left rear side Upper left rear side
Only a steel pipe
Connectable Only a hose can be Model 0250 0400 0800 Floor reinforcement
(or a PVC pipe) can
items connected.
be connected.
W567 W567 W967
Shelf size (mm)
* Water supplier shall be connected by the D450 D750 D750 Increase the floor load capacity of the
customer. Shelf weight 1.4kg 2.2kg 6.6kg inner chamber.
Shelf load capacity
10kg 10kg 30kg • 100 kg
(evenly distributed load)
• 200 kg
Water purifier (WS-1) Support strength* 90kg
• 300 kg
* Including shelf weight Standard specification: 70 kg
Removes all impurities and constantly
creates pure water suitable for
humidifying purposes. Heavy-duty shelf
Conductivity: 10μs/cm or less
Water production capacity: 12 L/h Used to hold heavy specimens ・ Load capacity: 30kg
(Water temperature: 25°C) exceeding the load capacity of the * The shelves fitted to the 0800 model as
Size: W400×H400×D280mm standard shelf. standard components have a load
capacity of 30kg.
・ Load capacity: 50kg
Support Floor load Chamber total Max. Qty.
Load resistance Weight / shelf
strength *2 resistance *3 load resistance *4 in Chamber
0250 ─ 2.7kg
30kg 90kg 70kg 100kg 3
0400 ─ 4.3kg
0250 ─ 3.2kg
50kg *1 100kg 70kg 100kg 0400 ─ 5.1kg 2
0800 ─ 12.1kg
Water leak detection system and dew *1 Including shelf weight
tray (P.10) to catch dripping water are *2 Brackets and supports are changed from standard accessories and brackets must be locked down
by screw.
also available to detect and prevent *3 The floor can be reinforced to support weights up to 300 kg. In this case, the chamber total load
water damages. resistance will also change.
*4 Chamber total load resistance: Sum of the loading weight of all shelves and the floor area loading
weight
8
Rapid-Rate Temperature
Options
Cycle Type
9
Rapid-Rate Temperature
Options
Cycle Type
Thermocouple Additional overheat protector Trouble buzzer
At tached to specimen to measure Additional preventive measures can be Buzzer notif ication when an er ror
specimen temperature. taken for excessive temperature rise in occurs.
Thermocouple with a brass ball tip the chamber, in addition to the standard
Standard Type
Thermocouple type T (Copper/Copper-Nickel) equipped overheat protector.
・ 2 m SPECIMEN Emergency stop pushbutton
TEMPERATURE INPUT EXTRA OVERHEAT
・ 4 m ( TYPE T ) PROTECTOR
追加温度過昇防止器
試料温度入力
・ 6 m (JIS T ) Stops the chamber immediately.
OPTION
EXTERNAL ALARM
SIGNAL MODE
外部警報出力
TIME SIGNALS
タイムシグナル出力
No.3 OVERCOOL PROTECTOR
温度過冷防止器
No.4 Overcool protector
OPTION
Power
POWERmeter
SUPPLY
SPECIMEN
No.5
MODE
EXTRA OVERHEAT
CONTROL INPUT
TEMPERATURE
FOR SPECIMEN
( TYPE T ) If the temperature inside the chamber
PROTECTOR
試料電源制御出力
試料温度入力 追加温度過昇防止器
This option (JISdisplays
No.1 T) the integral decreases
RECORDERexcessively,
OUTPUT the chamber
stops 記録計用出力
operating to prevent the speci-
OFF
OPTION
power consumption
No.2 of the chamber.
EXTERNAL ALARM
SIGNAL MODE
CHAMBER TEMPERATURE
Display
TIME range: 0 to 9999.99 kWh
SIGNALS 外部警報出力 mens from(TYPE T)being damaged.
タイムシグナル出力 TIME SIGNALS 槽内温度
No.6
External memory: SD memory タイムシグナル出力 card (JIS T )
OVERCOOL PROTECTOR
No.3
No.7
Location: Instrumentation panel 温度過冷防止器 With guard
No.4
No.8 OPTION
* The SD memory card is not supplied.
OPTION
No.5
No.9
POWER SUPPLY
ETHERNET MODE
ETHERNET
No.9
No. of levels: 3
No.10 MONITOR OUTPUT
(1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア )
OPTION
Image
10
Rapid-Rate Temperature
Features
Cycle Type
ARS・ARL・ARG・ARU
Temperature & Humidity Control Range
Standard Type
(In environment of ambient temperature of +23℃, no specimen.)
ARSF
100 98
90
80 Temperature & Humidity Range
70
Standard Type
Relative 60
Minimum temp.: -45°C/-75°C
Humidity 50 Maximum temp.: +180°C
(%rh)
40
Humid. (ARL & ARS only): 10 to 98%rh
30
20
10 Temperature Change Rate
0 Approx. 3K/min., with 50kg of
10 20 30 40 50 60 70 80 90 100
15 65 95 specimen*, -75⇔ +180°C. (ARS-1100)
Temperature (℃) This can also be used for acceleration
testing.
*Specimen as aluminum, including 12kg of
shelf
11
Rapid-Rate Temperature
Features
Cycle Type
ARS・ARL・ARG・ARU
Standard Type
inside of the chamber from the left and
the right.
Door Locks
Locks have been fitted on the doors for
convenience in order to prevent the door
from opening during testing and to
ensure careful management of
specimens and tests. Viewing window (option) Chamber lamp
12
PC
PC
Ethernet Intranet
(company LAN) 携帯電話
Rapid-Rate Temperature
スマートフォン
Controller
Mail server
Cycle Type
N instrumentation P-310
Program Copy and Computer Editing
Chamber lamp Color LCD Touch Panel
Standard Type
Edit
Chamber Lamp ON/OFF
The chamber lamp can be switched ON
小型環境試験器
and OFF from all screens. (Wi-Fi 機能搭載)
Multilingual Support
Touch navigation The language used by the instrumentation
Touch icon to show can be changed with the screen settings
Network navigation bar. 無線 LAN による接続例
(Japanese / English / Chinese
(simplified / traditional) / Korean). Wi-Fi ルーター
Wi-Fi router (オプション)
Information Function
PC The INFO icon will blink when chamber Ethernet
Ethernet
information requiring attention. スマートフ
小型環境試験器
・ Inspection Period Notifications
Smartphone Tablet controller
It is possible to randomly preset the
内蔵ワイヤレスダイレク トによ
AR series
period and details of inspections for
ワイヤレスダイレクト
humidifier plates and condenser(オプション)
filters.
13
Rapid-Rate Temperature
ARL −45 to +180℃・10 to 98%rh
Cycle Type
TEMPERATURE & HUMIDITY CHAMBER
Standard Type
Temp. variation in space 3.0K
Temp. performance *1
Scroll-type
Compressor
3.0 kw 3.75 kw
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 510 kg 600 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
200V AC 3φ50/60Hz 53 A 56 A
Temp. performance *1
Temp. rate Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
of change *2 Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 35 min. Within 45 min. Within 30 min. Within 40 min.
achievement +20 to −75℃
time Pull down time
Within 40 min. Within 50 min. Within 50 min. Within 50 min.
Test area temperature: +20℃
Max. allowable heat load
3000 W 4500 W
Temp. & humid. range +10 to +95℃ / 10 to 98%rh
Temp. & humid.
performance *1
Rotary-type Scroll-type
Compressor Unit 1: 3.0 kw ×1, Unit 1: 3.75 kw ×1,
Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1
Unit 2: 3.0 kw ×1 Unit 2: 3.75 kw ×1
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
W700×H800×D400 W700×H800×D700 W850×H1000×D800 W1100×H1000×D1000
Inside dimensions mm (inch) *3
(W27.6×H31.5×D15.8) (W27.6×H31.5×D27.6) (W33.5×H39.4×D31.5) (W43.3×H39.4×D39.4)
W900×H1742×D1455 W900×H1742×D1705 W1050×H1955×D1805 W1300×H1955×D2005
Outside dimensions mm (inch) *3
(W35.4×H68.6×D57.3) (W35.4×H68.6×D67.1) (W41.3×H77.0×D71.1) (W51.2×H77.0×D78.9)
Weight 390 kg 405 kg 615 kg 700 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
200V AC 3φ50/60Hz ─ ─ 63 A 70 A
Power 220V AC 3φ60Hz 38 A 38 A 58 A 64 A
supply *4 380V AC 3φ50Hz 24 A 24 A 28 A 32 A
400V AC 3φ50Hz *5 23 A 23 A 27 A 29 A
Noise level *6 57 dB 58 dB 62 dB 63 dB
Exhaust heat quantity kJ/h (kcal/h) 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185)
*1: At ambient temperature +20℃, no specimen. Performance shown *3: Excluding protrusions.
above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. *4: Power supply voltage fluctuation to be ±10% of rated value.
*2: Temperature rate of change in the temperature range excluding ±10% *5: Conforms to CE marking based on EU directives.
of max/min. temperature. *6: Measurements are to be taken in an anechoic room at a height of 1.2m
15 from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
Rapid-Rate Temperature
ARU −45 to +180℃
Cycle Type
TEMPERATURE CHAMBER
Standard Type
Temp. variation in space 3.0 K
Temp. performance *1
Scroll-type
Compressor
3.0 kw 3.75 kw
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 505 kg 595 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
200V AC 3φ50/60Hz 53 A 56 A
16
Rapid-Rate Temperature
TEMPERATURE CHAMBER
Temp. rate Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
of change *2 Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
+20 to +180℃
Temperature Heat up time
extremes Within 35 min. Within 45 min. Within 35 min. Within 45 min.
achievement +20 to −75℃
time Pull down time
Within 40 min. Within 50 min. Within 50 min. Within 50 min.
Test area temperature: +20℃
Max. allowable heat load
3000 W 4500 W
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Nichrome strip wire heater
Heater
(1.75 kW×2) (3 kW×2)
Cooler Plate fin cooler
Construction
Scroll-type
Compressor Unit 1: 2.2 kw ×1, Unit 1: 3.0 kw ×1, Unit 1: 3.75 kw ×1,
Unit 2: 2.2 kw ×1 Unit 2: 3.0 kw ×1 Unit 2: 3.75 kw ×1
Condenser Air-cooled condenser
Expansion system Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
W700×H800×D400 W700×H800×D700 W850×H1000×D800 W1100×H1000×D1000
Inside dimensions mm (inch) *3
(W27.6×H31.5×D15.8) (W27.6×H31.5×D27.6) (W33.5×H39.4×D31.5) (W43.3×H39.4×D39.4)
W900×H1742×D1455 W900×H1742×D1705 W1050×H1955×D1805 W1300×H1955×D2005
Outside dimensions mm (inch) *3
(W35.4×H68.6×D57.3) (W35.4×H68.6×D67.1) (W41.3×H77.0×D71.1) (W51.2×H77.0×D78.9)
Weight 385 kg 400 kg 615 kg 700 kg
100mm cable port (x2, one on the right & left sides), specimen power supply control terminal,
Equipment condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4),
Ethernet port (LAN port), USB memory port
Cable port rubber plug (φ100mm×2), Shelf brackets (18-8 Cr-Ni stainless steel),
Shelf (18-8 Cr-Ni stainless steel), Door key (×2 For door), Cartridge fuse (250V 0.4A, 5A, 8A),
Accessories
Wet-bulb wick (ARL, ARS), Specimen temperature measuring thermocouple (type T, 3m),
Specimen temperature input connector, Operation manual *Power cable is not included.
Allowable ambient conditions 0 to +40℃ (+32 to +104℉) / 75%rh max.
Utility requirements
200V AC 3φ50/60Hz ─ ─ 63 A 70 A
17
Rapid-Rate Temperature
Options
Cycle Type
Power cable Shelf, shelf bracket
Standard Type
* The chamber does not come with a power
cable.
Load capacity 50 kg
Shelf weight 3 kg 4 kg 8 kg
Communication cables
Additional cable port
Support strength 80 kg
・ RS-485 5m/ 10m/ 30m
Provided in addition / replacement of Safety precautions ・ GPIB 2m/ 4m
the standard cable ports.
● Do not use specimens which are explosive or flammable,
・ 50 mm diameter Viewing window
or which contain such substances. To do so could be
・ 100 mm diameter hazardous, as this may lead to fire or explosion.
* Each cable port is equipped with a silicone Used fornot
● Do observation of the
place corrosive specimens
materials in the chamber. If
sponge rubber plug. insidecorrosive
the chamber.
substances or liquid is used, the life of the unit
may be significantly
Dimensions: W340×H440 shortened
mm specifically because of the
corrosion of stainless steel, resin and silicone materials.
● Do not use living organisms or items that exceed the
allowable heat load as a specimen.
● Be sure to read the operation manual before operation.
Options
Cycle Type
A temperature & humidity recorder Additional preventive measures can be If a trouble occurs, the buzzer will alert
that utilizes a liquid-crystal display taken for excessive temperature rise in you of the situation.
fitted with a touch-panel. the chamber, in addition to the standard
Standard Type
No.2 SIGNAL
< Temperature
TIME SIGNALS & humidity外部警報出力type >
MODE
CHAMBER TEMPERATURE
mens from being damaged.
(TYPE T)
No. of input channel:
タイムシグナル出力 TIME SIGNALS
タイムシグナル出力
No.6 槽内温度
(JIS T )
OVERCOOL PROTECTOR
Temperature 1, Humidity 1 No.3 No.7
温度過冷防止器
(4 more channels can be turned No.8 ON)
No.4 OPTION
OPTION
No.5
No.9
POWER SUPPLY
ETHERNET MODE
No.2 OPTION
TIME SIGNALS External alarm terminal
CHAMBER TEMPERATURE
(TYPE T) Operation manual
タイムシグナル出力 槽内温度
No.6
(JIS T )
No.7 If the safety device of the chamber is ・ CD
No.8 activated,OPTIONalarm signal will be sent to ・ Booklet
SPECIMEN
ETHERNET
No.9
TEMPERATURE
( TYPE T )
INPUT remote location through this EXTRA terminal.
OVERHEAT
PROTECTOR
No.10 MONITOR OUTPUT 追加温度過昇防止器
試料温度入力 (1-5V DC LINEAR )
(JIS T )
モニタ出力 (DC1-5V リニア )
Temperature recorder (digital) EXTERNAL ALARM
OPTION Reports & certificates
SIGNAL MODE
外部警報出力 OPTION
Portable type TIME SIGNALS
タイムシグナル出力
・ Testing and inspection report
−100 to +200℃ 6 dots ・ Test data
No.3 OVERCOOL PROTECTOR
温度過冷防止器
Stops the
No.8
chamber immediately.
OPTION
No.9
ETHERNET
No.10 MONITOR OUTPUT
(1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア )
OPTION
19
Network
* Requires an intranet Supported browser: Internet Explorer 11
finished.
* An Intranet environment is required to Mail server
transmit e-mails.
AR series Mobile phone En
Stre
(Sold separately)
Copy
Intranet
Network
camera
Measuring
Test chambers of instrument
other manufacturers
*Please contact ESPEC for more information, about which products can be connected.
20
Network
OTHER PRODUCTS
21
OTHER PRODUCTS
TSA-43EL 240×460×370
TSA-303EL 970×460×670
TSA-73ES 410×460×370
High temp.:
TSA-73EH +60 to +200℃ 410×460×370
22
http://www.espec.co.jp/english
Head Office
3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan
Tel : 81-6-6358-4741 Fax : 81-6-6358-5500