REFRIGERANT SERVICE TOOLS

GAS LEAKAGE DETECTION / PREVENTION


REFRIGERANT SERVICE TOOLS

Refrigeration system analyzer

Simple operation just connect System AnalyzerⅡ PAT.

to manifold to judge the unit R32


applicable
condition !! Pressure 0 ~ 4.8MPa
Connecting port size 1/4" Flare (UNF 7/16 − 20 TPI)

Just connect to the manifold to use


as a system analyzer !!

200mm
VACUUM PUMPS

From refrigerant pressure &


temperature, automatically
calculate Superheat & Subcooling
by easy valve control !!
Refrigerant pressure Refrigerant Temperature
MANIFOLDS, CHARGING HOSES & VALVES

110mm

Super heat / Subcool Comdensation temperature / Evaparration temperature


※ Low pressure & High pressure with be displayed at the same time.

Measure the temperature of both low / high pressure ports


■ Dual K - Type temperature - compensated sensors allow for
simultaneous measurement at both suction and discharge
ports.

Automatic Superheat・Subcooling calculation


■ Automatically calculating Superheat/Subcooling temperatures
of 97 kinds of refrigerants. R11, R12, R13, R21, R22, R23, R32, R41, R113, R114, R115, R116,
R123, R124, R125, R134a, R141b, R142b, R143a, R152a, R218,
R236ea, R236fa、R245ca, R245fa, R290, R401A, R401B, R401C, R402A,
Addable new refrigerant data R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C,
R407D, R407F, R408A, R409A, R410A, R410B, R411A, R411B, R412A,
GAS LEAKAGE DETECTION & PREVENTION

■ Data of new refrigerant which is about to develop can be added Applicable


R413A, R414A, R414B, R416A, R417A, R418A, R419A, R420A, R421A,
by USB port. refrigerant
R421B, R422A, R422B, R422C, R422D, R423A, R424A, R425A, R426A,
R427A, R428A, R434A, R438A, R500, R501, R502, R503, R504, R507,
R507A, R508, R508A, R508B, R509, R509A, R600, R600a, R601, R601a,
Auto switch OFF function Altitude correcting function HFO-1234yf, R1234ze, R1233zd, R1270, R227ea, R407E, R407F, R409B,
■ Power off time selectable. R437A
Pressure sensing
−0.1psi, 0.01bar, 1kPa, 0.1MPa, 0.01kg / cm2
resolution
Back light Pressure sensing
0.5% / FS (25°C) • 1.0% / FS (12 ~ 55°C) • 2.0% / FS (−40 ~ 120°C)
accuracy
■ Ideal for job in dark
Pressure Proof : 6.8MPa / Burst : 10.3MPa
site with back light on.
Temperature sensor −73 ~ 315°C (K - type)
Temperature display Temperature ±1°C
0.1°C
resolution accuracy
Temperature Operating : −20 ~ 50°C / Storage : −29 ~ 77°C
Weight 0.53kg (Body)
Power 9V Alkaline battery
Standard accessories System Analyzer Ⅱ, Thermocouple (K - Type) × 1, Adapter (1/4" × 5/16") × 2

36
REFRIGERANT SERVICE TOOLS
Infrared (NDIR type) leak detector

DIRECT INSPECTION Leak Detector LD316

INFRARED
Code No.LD316E
( NDIR TYPE ) R32
Freon HFO - 1234yf Infrared sensor
LEAK DETECTOR applicable

For refrigerant leak detection of large fridge - freezer • large A / C • commercial A / C •


package A / C • room A / C • showcase • refrigerator • vending machine • car A / C.
With LED light at the probe tip, can search for refrigerant leakages in dark site such as,
in internal system, ceiling, basement, etc.
Alarm is changeable. (ON / OFF)

High-performance &
high-sensitivity infrared sensor !!
Long life !!

VACUUM PUMPS
Accurate leak detection with high - performance,
high - sensitivity with infrared sensor
(NDIR type), and 9 stages colour indicator.

PEEKHOLD Mode
Image of Leakage

Stay Level of Indicator Light LED lamps


Define
Detector leaking
Leakage point
bleep! bleep! bleep! bleep!

Stay Level of Indicator

MANIFOLDS, CHARGING HOSES & VALVES


■ When you press【PEEKHOLD】button during detecting, hold
the display at the maximum amount of leakage. LED indicator
stops at the point of the highest refrigerant concentration, and
always shows the highest refrigerant concentration during the
operation. Easily identify the leak location in this way.

Auto sensitivity switching mode

■ Depending on the amount of leakage, 3 - stages - sensitivity


automatically switching.
It can always detect with optimal sensitivity sensor.
184mm
Press【SENS】and hold for 2 secs, for Auto / Manual change.
For identifying the exact leakage position, manual mode is
recommended.
(Sensitivity is fixed and does not automatically change.)

CM mode
Detect with Higher Sensitivity
■ By pressing【CM】, detection
sensitivity increases to 3g /
GAS LEAKAGE DETECTION & PREVENTION

year.
For normal detection, detect
with standard mode and for 70mm
detection with better
sensitivity set the detection
sensitivity to 3g / year.
R410A, R407C, R404A, R507A, R134a, R12, R22, R500, R502,
Applicable refrigerant
HFO1234yf, R32, R245fa, etc
LED light at the probe tip
Detection method Infrared type
■ By pressing【LED light ON / OFF】, Gas introduction method Gas suction system
lights up. Sensitivity High : 4g / yr, Medium : 7g / yr, Low : 14g / yr, CM mode : 3g / yr
With the light, can detect for refrigerant Power Rechargeable lithium battery
leackages in internal system, ceiling, Time Reaction time : less than 1sec / Warm up : about 30 secs
and basement easily. Detection method Buzzer & 9 staged LED
Weight 495g
Temperature range working : 0 ~ 50°C / storage : –10 ~ 60°C
Standard accessories Leak check bottle, Spare filter × 5, AC adapter, Body cover, Storage case

37
REFRIGERANT SERVICE TOOLS

Heated semiconductor sensor leak detector

DIRECT INSPECTION Heated Sensor type Leak Detector (with UV light)


HEATED SEMICONDUCTOR Code No.Y69338

R32 HFO UV light : Heat

SENSOR LEAK DETECTOR applicable


Freon
1234yf High brightness UV LED 3
(UV wavelength 405±10nm)
semiconductor
sensor

For refrigerant leak detection of large fridge – freezer・large A / C・commercial A / C・


package A / C・room A / C・showcase・refrigerator・vending machine・car A / C.
Both AC / DC can be used.
Alarm is changeable. (ON / OFF)

Leak level LED displays the


amount of leakage by 9 stages !!
Bring closer the sensor unit to the piping to check.
VACUUM PUMPS

Search leakage position with the leak detection


signal sound. Possible to detect a small leak of each
type of refrigerant. Workable near electiricity with
sensor typed Leak Detector !!

Refrigerant gas Heated semiconductor sensor


enters from here
■ When the heated sensing element
Sensor element is exposed to refrigerant, the
electrochemical reaction changes
Heater
the resistance within the element
causing an alarm.
Heater circuit Sensitivity will not decrease with
Resistance exposure to dirt, oil, and water.
measurement circuit Service life is more than 300
Alarm circuit hours with minimal cleaning and no
adjustments.
MANIFOLDS, CHARGING HOSES & VALVES

UV Light
■ With high brightness UV LED Light,
can detect the leakage of A / C
containing fluorescent agent.

Flexible probe Flash LED


■ Probe can be kept bent. ■ The more the concentration
of the refrigerant gets 265mm
higher, the more point
deceleration gets faster.

Sensitivity 1.7g / year Sensor is replaceable


■ With high sensitivity of heat ■ Heated semiconductor
sensor, detects HFC sensor is replaceable by one
refrigerant. action.

Leak level LED


■ Digitally displays the leakage with 9 stages.

Measure of leak sensitivity


GAS LEAKAGE DETECTION & PREVENTION

Refrigerant R410A R407C R404A


Sensitivity / yr 1.7g 1.7g 1.7g
Refrigerant R507A R134a R12
Sensitivity / yr 1.7g 1.7g 1.7g 65mm

Refrigerant R22 R502 1234yf


Sensitivity / yr 0.9g 1.7g 4.3g
Refrigerant R32 R245fa
Sensitivity / yr 1.7g 20ppm
R410A, R407C, R404A, R507A, R134a, R12, R22, R500, R502,
※ Sensitivity is the value that was approved based on Applicable refrigerant
HFO1234yf, R32, R245fa, etc.
Standard SAE J 1627 & SAE J 2791.
Detection method Heated semiconductor sensor
Repair part Gas Introduction method Gas suction system
Power 100V or AA alkaline battery
Sensor for Replacement (with filter) : Code No. Y69384
Weight 480g (include battery)
Sensor Filter (5 PCS) : Code No. Y69385W
Temperature range working temperature : – 4 ~ 52°C
100V AC adapter, AA alkaline battery × 4, Sensor, Spare filter,
Standard accessories
Leak check bottle, Case

38
REFRIGERANT SERVICE TOOLS
Infrared (NDIR type) CO2 leak detector

CO2 Leak Detector For A / C with CO2, Hot water despenser


Code No.Y69396

Infrared Hi:under 400ppm (atmospheric concentration 350ppm)


CO2
sensor Lo:under 4,000ppm (atmospheric concentration 350ppm)

Display and buzz for sensitivity select and leak detection.


Easy operation with one button for power, sensitivity select and zero adjustment.
Infrared sensor lasts more than 2 years.

Applicable refrigerant CO2


Gas introduction
Detecting method Infrared sensor Gas suction system
method
Sensitivity Hi : under 400ppm Lo : 4,000ppm (atmospheric concentration 350ppm) 203mm

Weight 425g (with battery) Power Alkaline battery


Temperature range 0 ~ 50°C Dimension L : 203 × W : 63 × H:57mm
Standard accessories Alkaline battery, Spare filter, Case

VACUUM PUMPS
Repair part
CO2 Sensor : Code No.Y69398 Filter Kit (10pcs) : Code No.Y69397
63mm

Leak detector

Combustible Gas Detector


Code No.Y69373 HC (flammable)
Isobutane

Combustible gas Muting function Electrochemical method

Gas detection of HC refrigeration storage room, gas pipe, gas heater, etc.
Indicator displays the value of leak in 6 stages.
Low battery LED Indicates when the battery needs to be replaced.
Automatic calibration & zero setting. High sensitive
detection of

MANIFOLDS, CHARGING HOSES & VALVES


combustible gas
Applicable refrigerant
Methane, Isobutene, Propane, Methanol, Benzene, Ethan, Gasoline, Acetone, 264mm such as HC !
Butane, Acetylene, Toluene, Methyl alcohol, Ethylene, Ammonium, etc
Detecting method Electro chemical Sensitivity 15ppm (methane)
Power Alkaline battery × 4 Weight 406g (includes battery)
Dimension L : 65×W : 52×H : 264mm Temperature range 0 ~ 52°C
Standard accessories Sensor, Alkaline battery, Case

Repair part Sensor for Combustible Gas : Code No. Y69371


65mm

Combustible gas detector

Gas Mate
Code No.LB706600
HC (flammable)
Isobutane

Combustible gas Muting function Semiconductor sensor


GAS LEAKAGE DETECTION & PREVENTION

Gas detection of HC refrigeration storage room, gas pipe, gas heater, etc
Hydrocarbon gas and other gases can be detected with the advanced technology
Sensitive to 5ppm methane
Auto zero setting for ignoring background gas levels in test area
High sensitive
detection of
Applicable refrigerant
Methane, Natural gas, Propane, Butane, Isobutene, Ammonium, combustible gas
Cyclopentane, Ethan, Ethanol, etc
215mm such as HC !
Detecting method Semiconductor Sensitivity 5ppm (mathane)
1.5V Alkaline battery × 2
Power (40 hours) Weight 700g (includes battery)

Dimension L : 57 × W : 88 × H : 215mm Temperature range 0 ~ 45°C


Standard accessories Sensor, Alkaline battery × 2, Case

Repair part Sensor for Gas Mate : Code No. LB706700


57mm

39
REFRIGERANT SERVICE TOOLS

Spray type gas leak detector

DIRECT DETECTION Big Blu Big Blu for Low Temperature PAT.

BUBBLING LIQUID Eco friendly as biodegrading.


Contains no chlorine. (less corrosive than deionized water)
Large bubbles stay for long period to help detecting small leaks.
No freeze at –34°C !!
Applicable to
World No.1 sensitivity with spray type !! Spreads all over the surface because of the water soluble adhesion. refrigerators for food !!
For checking leakages of refrigerant
systems.

For low temperature

■ Just spray Big Blu to


pipings.
VACUUM PUMPS

Bubbles bulge and 0.95L 3.8L For refill 0.95L 3.8L For refill
easy to find a leakage. Item 0.95L 3.8L for refill 0.95L (low temperature) 3.8L for refill (low temperature)
Code No. RT100S RT100G RT150S RT150G
Amount 0.95L 3.8L 0.95L 3.8L
Temperature range 1.6 ~ 80°C − 34 ~ 94°C

For nitrogen gas shield pipes during brazing


Leakage prevention product
Nitrogen Blow Kit
NITROGEN BLOW KIT Code No.XP676

For removing moisture, foreign substances when plumbing.


Necessity of Nitrogen blowing Flushing of existing pipes to be used when installing cleaning less A / C.

Nitrogen blow prevents copper tube


without nitrogen blow
with nitrogen blow from oxide film during brazing

MANIFOLDS, CHARGING HOSES & VALVES

oxide film

■ Defective brazing or corrosion causes leakage


accidents. For preventing these accidents,
during brazing, use Nitrogen Blow Kit not to
make oxide film inside the pipe.
※ Applicable to not only brazing, but also to blowing before or after
flushing existing pipes or various blow works. 1/4"
1/4"
With valve core
Hose for Nitrogen Working pressure : 6.8MPa
Burst pressure : 27.5MPa
Pressure Primary side : 0 ~ 25MPa / Secondary side : 0 ~ 2.5MPa
Length Code No. Length Code No. Secondary adjustable pressure 0 ~ 1.0MPa
10m XP415 30m XP405 Hose Proof pressure : 5.0MPa / Burst pressure : 20.0MPa
20m XP425 40m XP435 Taper nozzle large (1/2" • 5/8" • 3/4"),Taper nozzle small (1/4" • 3/8"),Ball valve,
Standard accessories
1/4" hose for nitrogen 3m (XP410), Regulator for nitrogen blow, Case
※ Hose for nitrogen (XP410) is not applicable to airtight test.

For airtight test of plumbing and various systems by nitrogen gas


For airtight test of plumbing and various
systems Airtight Test Kit
Code No.XP681
AIRTIGHT TEST KIT For preventing refrigerant leakage.
GAS LEAKAGE DETECTION & PREVENTION

Pressure can be adjusted by a handle operation.


Necessity of airtight test
■ Even a connection looks perfect, it may leak Airtight test is necessary even
from somewhere. To prevent leakage, “Airtight a connecting looks perfect !!
test” is required as a final inspection.

Combination of ASADA “Airtight Test Kit” with


“Charge Clamp” realize more complete airtight
test.

1/4"
Realize piping without leakage !

Hose for Nitrogen Working pressure : 6.8MPa 1/4"


Burst pressure : 27.5MPa With valve core 1/4"

Length Code No. Length Code No. Pressure Primary side : 0 ~ 25MPa / Secondary side : 0 ~ 15MPa
10m XP415 30m XP405 Secondary adjustable pressure 0 ~ 8.0MPa
20m XP425 40m XP435 Hose Proof pressure : 6.8MPa / Burst pressure : 27.5MPa
Regulator for airtight test, 1/4" hose for nitrogen 3m × 2, Pressure gauge with T cheese,
Standard accessories
ø80mm single manifold, Adapter for different diameter 1/4" × 5/16", Case

40
REFRIGERANT SERVICE TOOLS
Mirror for a detection

System Service Mirror


leakage inspection Round : Code No.Y78100 Square • Small : Code No.Y78101
Square Large : Code No.Y78102

VISUAL APPEARANCE Ideal for checking narrow or hidden areas.

INSPECTION
Stainless steel mirror with 360° rotatable ball joint.
Extendable handle up to 700mm.

ø95mm

95 × 50mm

50 × 32mm

Round
Y78100
Square・Large

VACUUM PUMPS
Y78101
Square・Small
Y78102

Mirror for a detection

Survice Mirror with LED Light


Round : Code No.MTIM30 Square : Code No.MTIM24
Even the places not directly visible,
easy to find a leak location with an Ideal for checking narrow or hidden dark areas with LED light.
Stainless steel mirror with 360°rotatable ball joint.
inspection camera.
Extendable handle up to 750mm.
Button battery.

Visual inspection of piping & inside system


■ Check the appearance of the entire system by
auditory and sight.

MANIFOLDS, CHARGING HOSES & VALVES


Search for the presence of frost & bleeding oil
from various parts.
(Includes Head part)
280mm ~ 865mm
Visual inspection of the hard - to - see place
■ Search for the leakages with
Service Mirror or inspection
camera when checking the
back of pipes or narrow 285mm ~ 870mm
areas. Round Mirror size : ø 52mm (Includes Head part)
MTIM30 Head thickness : 10mm
Square Mirror size : 41 × 64mm
MTIM24 Head thickness : 10mm

For checking pipes, A/C, cars, etc

Clear Scope • Digital 100


Code No.TH100

Head diameter : 5.5mm Image reversal function

2 × Digital Zoom function Flexible Cable


GAS LEAKAGE DETECTION & PREVENTION

Inspection camera.

Li - Polymer Battery (2hours charge for 4hours use)


Battery 230mm
※ Voltage made to order
Camera Head diameter : ø 5.5mm
Camera cable length 1m
Display 3.5 TFT colour LCD / Resolution : 320 × 240 pixel
Weight 450g (Body)
Image • JPEG (300,000 pixels)
Saving format 39mm
Video • AVI (300,000 pixels)
Storage medium SD Card (Max. 32GB)
External output USB, AV 122mm
Standard Clear scope, Clear scope cable, AC adapter,
accessories Mini USB cable, AV cable, SD card 2GB, Carrying case

41
REFRIGERANT SERVICE TOOLS

Prevent refrigerant leakage from flare fittings


REFRIGERANT " LEAK-FREE " SEAL
FLARETITE
To seal flare fitting in room,
packaged & industrial air conditioner,
freezer, refrigerator and showcase, etc.
For service port, expansion valve, filter
dryer, ball valve, solenoid valve, pressure
& temperature regulator and branch pipe,
etc.

Prevent refrigerant leakage during operation


VACUUM PUMPS

■ Patented seal coated Loctite sealant.


■ Prevent leakage with stepped copper gasket.

Stepped sealant
Many cases of refrigerants leak from ■ Coated Loctite sealant.
flare fittings. If use Flaretite when ■ Special technology not to mix the sealant in the system.
installation and maintenance of
refrigeration equipment, it prevents Easy installation tional
Conven torque
ng
refrigerant leakage from flare fittings. tighteni

OK!!
■ You can use your torque wrench to tighten.
■ Just snap the Flaretite onto the end of male flare.

Refrigerant leakage test with damaged flare joint


MANIFOLDS, CHARGING HOSES & VALVES

Test result without Flaretite Test result with Flaretite

e 5MPa
Leakag
3 hours
age
at
after N leak
o
charged
with
2MPa nitrogen
scratch

Date / 2011.12.9
〈 Test condition 〉 Flare surface of Flare surface of
copper tube male flare

Scratch The secret of Flaretite to prevent leakage


Disrepair Flared copper tube
Sealing for dent and scratch
scratch toward axis direction Coating (Loctite)
Sealant fills scratchfills scratch
on the flare and prevents Base material(metal) (drawing)
leakage. Flare
Scratch surface
Flare seal point
Flare surface Seal - ring adheres to flare surface
Correct an error of flare angle by pressing and.
Room temperature during test Copper tube size Tightening torque Pressure test effective for maximum 1 degree error.
17°C 1/4” 16N • m Nitrogen gas 5MPa
GAS LEAKAGE DETECTION & PREVENTION

Structure of Flaretite & Flaretite Cu Easy installation Quick repair

Flaretite Flaretite Cu Snap – easily Patented tabs Quick & easy


❶ Loctite sealant ❶ Stepped copper gasket hold the seal in repair for leakage
❷ Stepped copper gasket (material : C1220 permissible substitute) place and support from flare fitting.
❸ Patented tab ❷ Patent – Clip function easy installation. Save time & cost
for repair.
❶ ❶


❸ ❷

■ Flaretite has been used for more than 5 years by major refregiration equipment Applicable to all kinds of refrigerant & refrigeration oil
manufacturer.
■ Flaretite has attracted a public attention in California where the regregerant
leakage is serious problem as it prevents refrigrant leakage from flare.

42
REFRIGERANT SERVICE TOOLS
Refrigerant "Leak - Free" seal

Flaretite PAT.
More th
an

5 yoefars
Loctite sealant For scratch on the flare nce!!
experie
Prevernt even large leakage by the Loctite Loctite sealant
sealant and the stepped copper gasket. Enter the scratch fills scratch on
Loctite sealant protects the face of fitting the flare and
from over- tightening. prevents leakage.
For repairing of filters, maintenance, and an
Loctite (No.517) does not harm refrigerant
equipment due to inert substance. Loctite sealant
expansion valve of existing HVAC equipment !!

Item Code No. QTY.


1/4" (10pcs) FT0414 1

3/8" (10pcs) FT0638 1

1/2" (10pcs) FT0812 1

5/8" (10pcs) FT1058 1

VACUUM PUMPS
3/4" (10pcs) FT1234 1

Trial 5 sizes set (each 2pcs : 10pcs) FT054 1

1/4" • 3/8" set (each 5pcs : 10pcs) FT061 1

1/4" • 1/2" set (each 5pcs : 10pcs) FT062 1


Flaretite
3/8" • 5/8" set (each 5pcs : 10pcs) FT063 1

3/8" • 3/4" set (each 5pcs : 10pcs) FT064 1

1/4" (100pcs) FT04140 1

3/8" (100pcs) FT06380 1 All 5 sizes set (※)

1/2" (100pcs) FT08120 1

5/8" (100pcs) FT10580 1

3/4" (100pcs) FT12340 1

All 5 sizes set (※) (100pcs) FT065 1


100 pcs

MANIFOLDS, CHARGING HOSES & VALVES


※ 1/4" • 3/8" • 1/2" • 5/8" • 3/4" × each 20pcs. (Total 100 pcs) 10 pcs

Refrigerant "Leak - Free" seal

Flaretite Cu PAT.
More th
an
Stepped copper gasket with patented tab. (※)
Copper seal is suitable for various flare fitting.
10 oyfears
nce!!
Rated for all common gases and fluids. experie
Applicable to angle gap of flare and gap between center of pipes.

For preventing leakage from filters and an expansion


Patent stepped copper gasket Flexible copper packing valve of HVAC equipment or installation of pipes !!
Prevent very small leaks that cannot be Its flexibility allows to be used for various
determined in airtight test with a stepped flare couplers.
copper gasket. Stepped shape prevents For flare couplers by copper, applicable to
leakages due to a slippage of the angle or any fluid.
center.
GAS LEAKAGE DETECTION & PREVENTION

Item Code No. QTY


1/4" (10pcs) FT0414N 1

3/8" (10pcs) FT0638N 1

1/2" (10pcs) FT0812N 1

5/8" (10pcs) FT1058N 1

3/4" (10pcs) FT1234N 1


Flaretite Cu
1/4" (100pcs) FT04140N 1

3/8" (100pcs) FT06380N 1

1/2" (100pcs) FT08120N 1

5/8" (100pcs) FT10580N 1

3/4" (100pcs) FT12340N 1 10 pcs 100 pcs

43
REFRIGERANT SERVICE TOOLS

"Leak - Free" seal

Flaretite for general flare fitting (For all common gases and fluids) PAT.
Same technology as refrigeration seals prevents all
For leak prevention from flare fitting of Hydraulic • Fuel • Gases. Back order common gas and fluiad leakage from flare fitting !
(JIC 37° flare • SAE 45° flare)
For leak prevention from plubming and connecting part of hose of Hydraulic equipment, Various type of seals for various flare fittings,
Garbage truck, Construction machine, Press machine, Injection moulding machine. gases & fluids and environment !

Standard carbon steel seals 304 Stainless steel seal with Loctite Vibra Seal coating
Size
LOCTITE Angle
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 ~ 1/4" 1 ~ 1/2" 2"
517 37° − 304 304 304 304 304 − 304 304 − −
Rated for – 40 ~ 148°C, JIC 37° flare

Special application seals 304 Stainless steel seal without coating


Size
LOCTITE Angle
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 ~ 1/4" 1 ~ 1/2" 2"
− 37° − 304 304 304 304 304 − 304 304 − −
Rated for all temperatures, JIC 37° flare
VACUUM PUMPS

Marine and corrosive environment seals 316 Stainless steel seal with Loctite Vibra Seal coating
Size
LOCTITE Angle
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 ~ 1/4" 1 ~ 1/2" 2"
37° 316 316 316 316 316 316 316 316 316 316 316
517 45° − 316 316 316 316 316 − − − − −
45° − Cu Cu Cu Cu Cu − − − − −
Rated for – 40 ~ 148°C, JIC 37° flare, SAE45° flare

Nuclear power seals 316 Stainles steel seal without coating


Size
LOCTITE Angle
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 ~ 1/4" 1 ~ 1/2" 2"
37° 316 316 316 316 316 316 316 316 − − −

45° − 316 316 316 316 316 − − − − −
Rated for all temperature, acceptable for radoation environments, JIC 37° flare, SAE 45° flare
MANIFOLDS, CHARGING HOSES & VALVES

High temp. oil and stea seals 316 Stainless steel seal with Loctite high temp graphite coating
Size
LOCTITE Angle
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1" 1 ~ 1/4" 1 ~ 1/2" 2"
37° 316 316 316 316 316 316 316 316 316 316 316
17015
37° Cu Cu Cu Cu Cu Cu Cu Cu Cu − −
Rated for – 40 ~ 648°C, JIC 37° flare

Refrigeration seals Copper seal with standard loctite Vibra seal coating

LOCTITE Angle
1/4" 3/8" 1/2" 5/8" 3/4"
517 37° Cu Cu Cu Cu Cu

Rated for – 40 ~ 148°C, JIC 37° flare

Gas leak preventing sealant

Nylog PAT.
For flare For valve opener For gasket

Blue : Code No.RT201B Red : Code No.RT200R


GAS LEAKAGE DETECTION & PREVENTION

HFC Nylog blue CFC HCFC Nylog red

Does not harm system as the component of Nylog is refrigeration oil. Leak prevention from flare, valve opener,
Nylog blue for sealing flare surface under high pressure of new type regrigerant.
gasket, screw and O-ring.
Prevents troubles due to the leak of HFC refrigerant.

Item Nylog blue Nylog red


Applicable refrigerant HFC refrigerant CFC • HCFC refrigerant
Working temperature −37°C ~ 210°C −34°C ~ 175°C
Capacity 30mL 30mL
Quantity in box 12 12

44