You are on page 1of 4

Column ID Column Tributary Area Dead Load psf Tributary Length (siding) Tributary Height of floor

C-B 3-7, C-C 3-7 1068 65 o


C-B 2 & 8, C-C 2 & 8 1068 65 oo
C-B 1 & 9, C-C 1 & 9 515.96 65 35 12
C-A 3-7, C-D 3-7 610 65 30 12
C-A 2 & 8, C-D 2 & 8 610 65 30 12
C-A 1 & 9, C-D 1 & 9 515.96 65 35 12

Column ID Area column tributary ft^2 Area siding tributary Load column pounds
C-B 3-7, C-C 3-7 1068 220008
C-B 2 & 8, C-C 2 & 8 1068 220008

C-B 1 & 9, C-C 1 & 9 516 420 116376


C-A 3-7, C-D 3-7 610 360 134300
C-A 2 & 8, C-D 2 & 8 610 360 134300
C-A 1 & 9, C-D 1 & 9 516 420 116376

Blue is Interior
Red is Exterior

Column ID Column Load (kips) factored Allowable 12ksf: Area footings Width of Square Footing
C-B 3-7, C-C 3-7 880.032 73.336 8.5636440842
C-B 2 & 8, C-C 2 & 8 880.032 73.336 8.5636440842
Blue is Interior
Red is Exterior
C-B 1 & 9, C-C 1 & 9 465.504 38.792 6.2283224066
C-A 3-7, C-D 3-7 537.2 44.7666666667 6.6907896893
C-A 2 & 8, C-D 2 & 8 537.2 44.7666666667 6.6907896893
C-A 1 & 9, C-D 1 & 9 465.504 38.792 6.2283224066

CORRECTED AS OF 4/10/2017 Width of footings per Column Adjusted for Construcability


C-B 3-7, C-C 3-7 6.2221378963 6.5
C-B 2 & 8, C-C 2 & 8 6.2221378963 6.5

C-B 1 & 9, C-C 1 & 9 4.5612498287 5


C-A 3-7, C-D 3-7 4.8900408996 5
C-A 2 & 8, C-D 2 & 8 4.8900408996 5
C-A 1 & 9, C-D 1 & 9 4.5612498287 5
Siding Load psf Live Load psf Footing Area Depth of Footing Allowable Bearing Pressure
20 80 3.5 12 ksf
20 80 3.5 12 ksf
20 80 3.5 12 ksf
20 80 3.5 12 ksf
20 80 3.5 12 ksf
20 80 3.5 12 ksf
20 80

One floor Column Load (kips) Column Load (kips)


220.008 880.032
220.008 880.032

116.376 465.504
134.3 537.2
134.3 537.2
116.376 465.504
BxW Dimensions of Footing Column ID
6.5x6.5 C-B 3-7, C-C 3-7
6.5x6.5 C-B 2 & 8, C-C 2 & 8
^^Interior Columns
vv Exterior Columns
5x5 C-B 1 & 9, C-C 1 & 9
5x5 C-A 3-7, C-D 3-7
5x5 C-A 2 & 8, C-D 2 & 8
5x5 C-A 1 & 9, C-D 1 & 9